1
|
536 Not only 5–base pair deletions in the intergenic region of the intercellular adhesion operon, but also mutations in the repressor of the intercellular adhesion operon lead to a mucoid phenotype in Staphylococcus aureus residing in the airways of people with cystic fibrosis. J Cyst Fibros 2022. [DOI: 10.1016/s1569-1993(22)01226-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
2
|
ePS3.01 Preliminary results of an ongoing study, which determines the prevalence and possible impact of mucoid Staphylococcus aureus on lung disease of people with cystic fibrosis. J Cyst Fibros 2022. [DOI: 10.1016/s1569-1993(22)00299-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
3
|
EPS3.08 Evaluation of a fixed-step eradication regime in children with cystic fibrosis and detection of Pseudomonas aeruginosa. J Cyst Fibros 2021. [DOI: 10.1016/s1569-1993(21)01025-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
4
|
Characterization of a preclinical PET insert in a 7 tesla MRI scanner: beyond NEMA testing. Phys Med Biol 2020; 65:245016. [PMID: 32590380 DOI: 10.1088/1361-6560/aba08c] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
This study evaluates the performance of the Bruker positron emission tomograph (PET) insert combined with a BioSpec 70/30 USR magnetic resonance imaging (MRI) scanner using the manufacturer acceptance protocol and the NEMA NU 4-2008 for small animal PET. The PET insert is made of 3 rings of 8 monolithic LYSO crystals (50 × 50 × 10 mm3) coupled to silicon photomultipliers (SiPM) arrays, conferring an axial and transaxial FOV of 15 cm and 8 cm. The MRI performance was evaluated with and without the insert for the following radiofrequency noise, magnetic field homogeneity and image quality. For the PET performance, we extended the NEMA protocol featuring system sensitivity, count rates, spatial resolution and image quality to homogeneity and accuracy for quantification using several MRI sequences (RARE, FLASH, EPI and UTE). The PET insert does not show any adverse effect on the MRI performances. The MR field homogeneity is well preserved (Diameter Spherical Volume, for 20 mm of 1.98 ± 4.78 without and -0.96 ± 5.16 Hz with the PET insert). The PET insert has no major effect on the radiofrequency field. The signal-to-noise ratio measurements also do not show major differences. Image ghosting is well within the manufacturer specifications (<2.5%) and no RF noise is visible. Maximum sensitivity of the PET insert is 11.0% at the center of the FOV even with simultaneous acquisition of EPI and RARE. PET MLEM resolution is 0.87 mm (FWHM) at 5 mm off-center of the FOV and 0.97 mm at 25 mm radial offset. The peaks for true/noise equivalent count rates are 410/240 and 628/486 kcps for the rat and mouse phantoms, and are reached at 30.34/22.85 and 27.94/22.58 MBq. PET image quality is minimally altered by the different MRI sequences. The Bruker PET insert shows no adverse effect on the MRI performance and demonstrated a high sensitivity, sub-millimeter resolution and good image quality even during simultaneous MRI acquisition.
Collapse
|
5
|
438P Interim safety analysis of the phase IIb study of ramucirumab in combination with TAS102 vs. TAS102 monotherapy in metastatic colorectal cancer: The RAMTAS trial of the German AIO. Ann Oncol 2020. [DOI: 10.1016/j.annonc.2020.08.549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
6
|
1502TiP Paclitaxel + ramucirumab versus paclitaxel alone in patients with squamous-cell carcinoma of the esophagus, refractory or intolerant to combination therapy with fluoropyrimidine and platinum-based drugs - RAMOS, a randomized phase II trial of the German Gastric Group of the AIO. Ann Oncol 2020. [DOI: 10.1016/j.annonc.2020.08.2093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
7
|
1443P Modified FOLFOX versus modified FOLFOX plus nivolumab and ipilimumab in patients with previously untreated advanced or metastatic adenocarcinoma of the stomach or gastroesophageal junction – Safety Results from AIO-STO-0417: A randomized phase II trial of the German Gastric Group of the AIO. Ann Oncol 2020. [DOI: 10.1016/j.annonc.2020.08.1949] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023] Open
|
8
|
P293 Physical activity in children and adolescents with cystic fibrosis – do they move enough? J Cyst Fibros 2020. [DOI: 10.1016/s1569-1993(20)30622-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
9
|
P321 Respiratory physiotherapy for children and adolescents with cystic fibrosis – is there a link between adherence and clinical health status? J Cyst Fibros 2020. [DOI: 10.1016/s1569-1993(20)30650-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
10
|
Modified FOLFOX versus modified FOLFOX plus nivolumab and ipilimumab in patients with previously untreated advanced or metastatic adenocarcinoma of the stomach or gastroesophageal junction: Moonlight, a randomized phase II trial of the German Gastric Group of the AIO. Ann Oncol 2019. [DOI: 10.1093/annonc/mdz247.161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
11
|
P469 From paediatric to adult care - improvement of a structural program of transition at the Cystic Fibrosis Centre of Hannover Medical School. J Cyst Fibros 2019. [DOI: 10.1016/s1569-1993(19)30761-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
12
|
P201 Adherence in nebulisation therapy of paediatric patients with cystic fibrosis. J Cyst Fibros 2019. [DOI: 10.1016/s1569-1993(19)30495-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
13
|
Low-Dose Imaging in a New Preclinical Total-Body PET/CT Scanner. Front Med (Lausanne) 2019; 6:88. [PMID: 31131277 PMCID: PMC6509903 DOI: 10.3389/fmed.2019.00088] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2018] [Accepted: 04/09/2019] [Indexed: 12/17/2022] Open
Abstract
Ionizing radiation constitutes a health risk to imaging scientists and study animals. Both PET and CT produce ionizing radiation. CT doses in pre-clinical in vivo imaging typically range from 50 to 1,000 mGy and biological effects in mice at this dose range have been previously described. [18F]FDG body doses in mice have been estimated to be in the range of 100 mGy for [18F]FDG. Yearly, the average whole body doses due to handling of activity by PET technologists are reported to be 3–8 mSv. A preclinical PET/CT system is presented with design features which make it suitable for small animal low-dose imaging. The CT subsystem uses a X-source power that is optimized for small animal imaging. The system design incorporates a spatial beam shaper coupled with a highly sensitive flat-panel detector and very fast acquisition (<10 s) which allows for whole body scans with doses as low as 3 mGy. The mouse total-body PET subsystem uses a detector architecture based on continuous crystals, coupled to SiPM arrays and a readout based in rows and columns. The PET field of view is 150 mm axial and 80 mm transaxial. The high solid-angle coverage of the sample and the use of continuous crystals achieve a sensitivity of 9% (NEMA) that can be leveraged for use of low tracer doses and/or performing rapid scans. The low-dose imaging capabilities of the total-body PET subsystem were tested with NEMA phantoms, in tumor models, a mouse bone metabolism scan and a rat heart dynamic scan. The CT imaging capabilities were tested in mice and in a low contrast phantom. The PET low-dose phantom and animal experiments provide evidence that image quality suitable for preclinical PET studies is achieved. Furthermore, CT image contrast using low dose scan settings was suitable as a reference for PET scans. Total-body mouse PET/CT studies could be completed with total doses of <10 mGy.
Collapse
|
14
|
237Prevalence of infective endocarditis in enterococcus faecalis bacteraemia: a prospective multicenter screening study. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy564.237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
15
|
Radial magnetic resonance imaging (MRI) using a rotating radiofrequency (RF) coil at 9.4 T. NMR IN BIOMEDICINE 2018; 31:e3860. [PMID: 29280211 DOI: 10.1002/nbm.3860] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2017] [Revised: 08/20/2017] [Accepted: 10/13/2017] [Indexed: 06/07/2023]
Abstract
The rotating radiofrequency coil (RRFC) has been developed recently as an alternative approach to multi-channel phased-array coils. The single-element RRFC avoids inter-channel coupling and allows a larger coil element with better B1 field penetration when compared with an array counterpart. However, dedicated image reconstruction algorithms require accurate estimation of temporally varying coil sensitivities to remove artefacts caused by coil rotation. Various methods have been developed to estimate unknown sensitivity profiles from a few experimentally measured sensitivity maps, but these methods become problematic when the RRFC is used as a transceiver coil. In this work, a novel and practical radial encoding method is introduced for the RRFC to facilitate image reconstruction without the measurement or estimation of rotation-dependent sensitivity profiles. Theoretical analyses suggest that the rotation-dependent sensitivities of the RRFC can be used to create a uniform profile with careful choice of sampling positions and imaging parameters. To test this new imaging method, dedicated electronics were designed and built to control the RRFC speed and hence positions in synchrony with imaging parameters. High-quality phantom and animal images acquired on a 9.4 T pre-clinical scanner demonstrate the feasibility and potential of this new RRFC method.
Collapse
|
16
|
IPD2.12 Respiratory physiotherapy for children with cystic fibrosis at infancy and early childhood – an actual state-target-analysis in consideration of parental influences on therapy adherence. J Cyst Fibros 2017. [DOI: 10.1016/s1569-1993(17)30362-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
17
|
Image Reconstruction for a Rotating Radiofrequency Coil (RRFC) Using Self-Calibrated Sensitivity From Radial Sampling. IEEE Trans Biomed Eng 2016; 64:274-283. [PMID: 27101591 DOI: 10.1109/tbme.2016.2552489] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The purpose of this study was to develop a practical magnetic resonance imaging (MRI) scheme for the latest rotating radiofrequency coil (RRFC) design at 9.4 T. The new prototype RRFC was integrated with an optical sensor to facilitate recording of its angular positions relative to the sequence timing. In imaging, the RRFC was used together with radial k-space trajectories. To recover the image, the radial spokes were grouped according to the coil locations. Using an Eigen-decomposition approach, an array of location-dependent sensitivity maps was extracted from the central regions of the segmented k-space, enabling parallel-imaging techniques for image recovery in a straightforward manner. When the RRFC angular velocity is carefully designed and accurately controlled according to the sequence timing, the encoding by means of varying RRFC sensitivity maps can be accurately calibrated for a faithful image recovery. Approximations were made to counteract the variations of the RRFC angular velocity, providing successful image reconstruction at 9.4 T. The current study demonstrated a new and practical imaging scheme for RRFC-MRI. It is able to extract the temporally varying sensitivity maps retrospectively from the k-space acquisition itself, without resorting to electromagnetic simulation or numerical interpolation. The proposed imaging scheme and the supporting engineering solutions of the RRFC prototype enable accurate image reconstructions. These new developments pave the way for routine applications of the RRFC, and bode well for its further development in providing simultaneous multinuclear imaging by incorporating, for example, independent X-nuclear coil elements into the rotating structure.
Collapse
|
18
|
Small animal PET based on 16x16 TSV-MPPCs and monolithic crystals. EJNMMI Phys 2016; 2:A16. [PMID: 26956271 PMCID: PMC4798668 DOI: 10.1186/2197-7364-2-s1-a16] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
19
|
WS09.3 Professional quality of life among CF healthcare providers. J Cyst Fibros 2015. [DOI: 10.1016/s1569-1993(15)30054-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
20
|
ePS05.7 Individual caloric intake in cystic fibrosis (CF) – how to calculate? J Cyst Fibros 2015. [DOI: 10.1016/s1569-1993(15)30166-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
21
|
Die Mukoviszidose Transitionsambulanz an der Medizinischen Hochschule Hannover. Pneumologie 2014. [DOI: 10.1055/s-0034-1368030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
22
|
WS19.9 A prospective multicenter study to dissect Staphylococcus aureus-colonization from infection in cystic fibrosis patients. J Cyst Fibros 2013. [DOI: 10.1016/s1569-1993(13)60122-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
23
|
253 Phase angle (PA) from bioelectrical impedance analysis (BIA) in children with cystic fibrosis (CF). J Cyst Fibros 2012. [DOI: 10.1016/s1569-1993(12)60422-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
24
|
The design of a double-tuned two-port surface resonator and its application to in vivo hydrogen- and sodium-MRI. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2012; 217:10-18. [PMID: 22391488 DOI: 10.1016/j.jmr.2012.02.002] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2011] [Revised: 01/06/2012] [Accepted: 02/05/2012] [Indexed: 05/31/2023]
Abstract
The design and construction of a two-port surface transceiver resonator for both (1)H-and (23)Na-MRI in the rodent brain at 7 T is described. Double-tuned resonators are required for accurately co-registering multi-nuclei data sets, especially when the time courses of (1)H and (23)Na signals are of interest as, for instance, when investigating the pathological progression of ischaemic stroke tissue in vivo. In the current study, a single-element two-port surface resonator was developed wherein both frequency components were measured with the same detector element but with each frequency signal routed along different output channels. This was achieved by using the null spot technique, allowing for optimal variable tuning and matching of each channel in situ within the MRI scanner. The (23)Na signal to noise ratio, measured in the ventricles of the rat brain, was increased by a factor of four compared to recent state-of-the-art rat brain studies reported in the literature. The resonator's performance was demonstrated in an in vivo rodent stroke model, where regional variations in (1)H apparent diffusion coefficient maps and the (23)Na signal were recorded in an interleaved fashion as a function of time in the acute phase of the stroke without having to exchange, re-adjust, or re-connect resonators between scans. Using the practical construction steps described in this paper, this coil design can be easily adapted for MRI of other X-nuclei, such as (17)O, (13)C, (39)K, and (43)Ca at various field strengths.
Collapse
|
25
|
Regional and temporal variations in tissue sodium concentration during the acute stroke phase. Magn Reson Med 2011; 67:740-9. [PMID: 21678490 DOI: 10.1002/mrm.23031] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2010] [Revised: 05/05/2011] [Accepted: 05/05/2011] [Indexed: 11/11/2022]
Abstract
A technique for noninvasively quantifying the concentration of sodium ((23) Na) ions was applied to the study of ischemic stroke. (23) Na-magnetic resonance imaging techniques have shown considerable potential for measuring subtle changes in ischemic tissue, although studies to date have suffered primarily from poor signal/noise ratio. In this study, accurate quantification of tissue sodium concentration (TSC) was achieved in (23) Na images with voxel sizes of 1.2 μL acquired in 10 min. The evolution of TSC was investigated from 0.5 to 8 h in focal cortical and subcortical ischemic tissue following permanent middle cerebral artery occlusion in the rat (n = 5). Infarct volumes determined from TSC measurements correlated significantly with histology (P = 0.0006). A delayed linear model was fitted to the TSC time course data in each voxel, which revealed that the TSC increase was more immediate (0.2 ± 0.1 h delay time) in subcortical ischemic tissue, whereas it was delayed by 1.6 ± 0.5 h in ischemic cortex (P = 0.0002). No significant differences (P = 0.5) were measured between TSC slope rates in cortical (10.2 ± 1.1 mM/h) and subcortical (9.7 ± 1.1 mM/h) ischemic tissue. The data suggest that any TSC increase measured in ischemic tissue indicates infarction (core) and regions exhibiting a delay to TSC increase indicate potentially salvageable tissue (penumbra).
Collapse
|
26
|
52 Protein analysis of mutant CFTR in human tissues. J Cyst Fibros 2011. [DOI: 10.1016/s1569-1993(11)60071-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
27
|
A double-tuned1H/23Na dual resonator system for tissue sodium concentration measurements in the rat brain via Na-MRI. Phys Med Biol 2010; 55:7681-95. [DOI: 10.1088/0031-9155/55/24/019] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
28
|
Effekt einer zusätzlich geplanten Flüssigkeitssubstitution bei Frühgeborenen ≤32 SSW mit fototherapiepflichtiger Hyperbilirubinämie. KLINISCHE PADIATRIE 2010. [DOI: 10.1055/s-0030-1261354] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
29
|
Dopplersonografische Flussmuster bei Frühgeborenen ≤32 SSW mit unterschiedlichen Flüssigkeitsregimes während fototherapiepflichtiger Hyperbilirubinämie. KLINISCHE PADIATRIE 2010. [DOI: 10.1055/s-0030-1261596] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
30
|
Continuous vs thrice-daily ceftazidime for elective intravenous antipseudomonal therapy in cystic fibrosis. Infection 2009; 37:418-23. [DOI: 10.1007/s15010-009-8116-5] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2008] [Accepted: 01/08/2009] [Indexed: 10/20/2022]
|
31
|
Long-term effects of a partially supervised conditioning programme in cystic fibrosis. Eur Respir J 2009; 35:578-83. [DOI: 10.1183/09031936.00062409] [Citation(s) in RCA: 105] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
32
|
TIDES-CF Study: Who participates in psychosocial trials? J Cyst Fibros 2009. [DOI: 10.1016/s1569-1993(09)60347-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
33
|
Persistent low thymic activity and non-cardiac mortality in children with chromosome 22q11.2 microdeletion and partial DiGeorge syndrome. Clin Exp Immunol 2008; 155:189-98. [PMID: 19040613 DOI: 10.1111/j.1365-2249.2008.03809.x] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
A subgroup of patients with 22q11.2 microdeletion and partial DiGeorge syndrome (pDGS) appears to be susceptible to non-cardiac mortality (NCM) despite sufficient overall CD4(+) T cells. To detect these patients, 20 newborns with 22q11.2 microdeletion and congenital heart disease were followed prospectively for 6 years. Besides detailed clinical assessment, longitudinal monitoring of naive CD4(+) and cytotoxic CD3(+)CD8(+) T cells (CTL) was performed. To monitor thymic activity, we analysed naive platelet endothelial cell adhesion molecule-1 (CD31(+)) expressing CD45RA(+)RO(-)CD4(+) cells containing high numbers of T cell receptor excision circle (T(REC))-bearing lymphocytes and compared them with normal values of healthy children (n = 75). Comparing two age periods, low overall CD4(+) and naive CD4(+) T cell numbers were observed in 65%/75%, respectively, of patients in period A (< 1 year) declining to 22%/50%, respectively, of patients in period B (> 1/< 7 years). The percentage of patients with low CTLs (< P10) remained robust until school age (period A: 60%; period B: 50%). Low numbers of CTLs were associated with abnormally low naive CD45RA(+)RO(-)CD4(+) T cells. A high-risk (HR) group (n = 11) and a standard-risk (SR) (n = 9) group were identified. HR patients were characterized by low numbers of both naive CD4(+) and CTLs and were prone to lethal infectious and lymphoproliferative complications (NCM: four of 11; cardiac mortality: one of 11) while SR patients were not (NCM: none of nine; cardiac mortality: two of nine). Naive CD31(+)CD45RA(+)RO(-)CD4(+), naive CD45RA(+)RO(-)CD4(+) T cells as well as T(RECs)/10(6) mononuclear cells were abnormally low in HR and normal in SR patients. Longitudinal monitoring of naive CD4(+) and cytotoxic T cells may help to discriminate pDGS patients at increased risk for NCM.
Collapse
|
34
|
Abstract
OBJECTIVE Inert gas multiple breath washout (MBW) for measuring Lung Clearance Index using mass spectrometry and 4% sulfur hexafluoride (SF(6)) as the tracer gas has been shown to be sensitive for detecting early Cystic Fibrosis (CF) lung disease. However, mass spectrometry requires bulky equipment and is expensive to buy and maintain. A novel sidestream ultrasonic device may overcome this problem. The aims of this study were to assess the feasibility and clinical validity of measuring lung volume (functional residual capacity, FRC) and the LCI using the sidestream ultrasonic flow sensor in children and adolescents with CF in relation to spirometry and plain chest radiographs. PATIENTS AND METHODS MBW using the sidestream ultrasonic device and conventional spirometry were performed in 26 patients with CF and 22 healthy controls. RESULTS In the controls (4.7-17.7 years) LCI was similar to that reported using mass spectrometry (mean (SD) 6.7 (0.5)). LCI was elevated in 77% of the CF children (6.8-18.9 years), whereas spirometry was abnormal in only 38.5%, 61.5%, and 26.9% for FEV(1), MEF(25), and FEV(1)/FVC, respectively. This was more marked in children <10 years. LCI correlated with the Crispin-Norman score, whereas FEV(1) did not. CONCLUSIONS Sidestream ultrasonic MBW is a valid and simple alternative to mass spectrometry for assessing ventilation homogeneity in children.
Collapse
|
35
|
Recurrence of PSA after early treatment: a long-term follow-up study. J Cyst Fibros 2008. [DOI: 10.1016/s1569-1993(08)60124-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
36
|
197 Clinical follow up after liver transplantation in children with cystic fibrosis. J Cyst Fibros 2007. [DOI: 10.1016/s1569-1993(07)60180-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
37
|
|
38
|
Abstract
It is unclear whether a relationship between physical activity (PA) and maximal oxygen uptake (V'(O2,max)) exists in cystic fibrosis (CF) and, if so, whether the relationship reflects a direct effect or is mediated by the effects of confounding variables, such as pulmonary or muscle function. The objective of the present study was to determine the relationship between PA and V'(O2,max) in CF while adjusting for possible influences of confounding factors. In total, 36 female and 35 male patients with CF from Germany and Switzerland (aged 12-40 yrs, forced expiratory volume in one second (FEV1) 25-107% predicted) were studied. A Wingate test was employed to measure muscle power. PA was monitored for 7 days and expressed in two ways: 1) average daily accelerometer count (ADAC) and 2) time spent in moderate-to-vigorous PA (MVPA). V'(O2,max) was determined during an incremental cycle exercise test to volitional fatigue. PA was positively related to V'(O2,max). In a multiple linear regression analysis, height, sex, FEV1, muscle power and ADAC (additionally explained variance 2.5%) or time spent in MVPA (additionally explained variance 3.7%) were identified as independent predictors of V'(O2,max). In conclusion, high levels of physical activity in addition to good muscular and pulmonary functions are associated with a high aerobic capacity in cystic fibrosis.
Collapse
|
39
|
Experimental analysis of parallel excitation using dedicated coil setups and simultaneous RF transmission on multiple channels. Magn Reson Med 2006; 54:994-1001. [PMID: 16155886 DOI: 10.1002/mrm.20646] [Citation(s) in RCA: 115] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
An experimental implementation and first performance analysis of parallel spatially selective excitation with an array of transmit coils and simultaneous transmission of individual waveforms on multiple channels is presented. This technique, also known as Transmit SENSE, uses the basic idea of parallel imaging to shorten the k-space trajectories that accompany multidimensional excitation pulses, and hence shorten the duration of such pulses. So far, this concept has only been presented in simulations and semi-experimental studies since no hardware setup had been available for a full experimental realization. In this study, a hardware solution, in combination with a dedicated coil setup, is presented to overcome this limitation, and in several experiments of localized excitation and transmit field inhomogeneity compensation the practical feasibility of Transmit SENSE is demonstrated and a first performance analysis is given.
Collapse
|
40
|
Abstract
UNLABELLED Inflammation is a hallmark in the pathogenesis of pulmonary destruction in cystic fibrosis (CF). There is no proven effective systemic anti-inflammatory treatment for CF patients with advanced pulmonary disease. Methotrexate (MTX) is known as an effective anti-inflammatory treatment in asthma and in juvenile rheumatoid arthritis. The question was: Is an improvement in pulmonary function achievable with low-dose MTX in patients with cystic fibrosis and advanced pulmonary disease.? METHODS We treated five CF patients with advanced pulmonary disease, who deteriorated in spite of intensive conventional therapy on an individual basis with low-dose MTX. FEV1% and immunoglobulin G (IgG) serum levels were followed from the year before to the year after starting with MTX. RESULTS In the year before starting with MTX, FEV1% decreased (median: 10% FEV1; range 9-15% FEV1; P<0.005) after starting with MTX, FEV1% increased (median: 9% FEV1; range: 2-15% FEV1; P<0.05). IgG changed (median: -2 g/l; range: 0.2 to -7.3 g/l) in the first year with MTX. CONCLUSION These preliminary data suggest a beneficial effect of MTX even in advanced pulmonary disease in CF patients and supports the need for a controlled prospective study.
Collapse
|
41
|
Development and characterisation of a ceramic HF-resonator for the MR-tomography. BIOMED ENG-BIOMED TE 2003; 47 Suppl 1 Pt 2:758-61. [PMID: 12465295 DOI: 10.1515/bmte.2002.47.s1b.758] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Future trends in magnetic resonance imaging (MRI) lead to higher magnetic field strengths of the static magnetic fields and as an implication of that to much higher frequencies. Nowadays a common model of a send-receive coil is the birdcage resonator. However it is very difficult to find an optimal L/C-relation for the capacities and inductivities at frequencies above 300 MHz. The idea is to build a completely new send-receive resonator without discrete network elements. The solution presented in this work is the development of a fully ceramic resonator with a high dielectric constant (between 30-100) and a low loss factor (tan delta approximately 10(3)). This approach has shown to produce a stable transversal magnetic field at the desired MR-frequencies above 300 MHz.
Collapse
|
42
|
Simulation of a birdcage and a ceramic cavity HF-resonator for high magnetic fields in magnetic resonance imaging. BIOMED ENG-BIOMED TE 2003; 47 Suppl 1 Pt 2:754-7. [PMID: 12465294 DOI: 10.1515/bmte.2002.47.s1b.754] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The aim of this work was the 3D-simulation of a dielectric resonator for high-field-MRI. A 12-rod-bird-cage-resonator was simulated in a first step, in order to verify the capability of the commercial simulation software MAFIA to simulate homogeneous, transversal B-fields in resonators. The second step was the simulation of frequency-independent dielectric ceramic resonators for static magnetic field strengths of 7 T and 12 T (294 MHz and 504 MHz respectively). The results were compared to the measured results of a manufactured TiO2- and a Al2O3-resonator. Only minor deviations showed up. These results led to the conclusion that dielectric resonators for high field MRI can be optimised using numerical field calculation software.
Collapse
|
43
|
[Numerical calculation of HF antennas and their interaction with dielectric media in MRI]. BIOMED ENG-BIOMED TE 2003; 47 Suppl 1 Pt 1:408-11. [PMID: 12451878 DOI: 10.1515/bmte.2002.47.s1a.408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
At high field MRI the wavelength within the object under investigation is comparable to the dimensions of the human head or body. The development of MR coils, under notice of all safety aspects, can be speed up dramatically by the use of numerical analysis instead of experimental methods. We use the commercially available software packages CONCEPT and MAFIA. We developed new methods for calculating the rf-fields in given structures driven by current, voltage or power sources. With the use of new NMR-methods the amplitude- and phase distribution of the magnetic rf-field and the distribution of the SAR inside the rf-coils, loaded with phantoms, are measured and compared with simulations. The results of the measurements and the simulations of the magnetic rf-field distribution and SAR distribution show a good correspondence.
Collapse
|
44
|
Abstract
Intraalveolar leukocyte accumulation is one of the hallmarks during respiratory distress. In the intraalveolar space, leukocyte activation is mediated by pathogens, cytokines, and different ligands binding to adhesion molecules. Leukocyte stimulation via the adhesion molecule L-selectin is specifically induced by ligands expressed on leukocytes, platelets, endothelial cells, or lipopolysaccharide. Recently, we have demonstrated that leukocyte activation by L-selectin transmits several intracellular signaling cascades resulting in capping and cytoskeletal changes, the activation of kinases and neutral sphingomyelinase, the recruitment of adaptor proteins to the cell membrane, the activation of the small G-proteins Ras and Rac, and the release of oxygen. In the present study, we examined the effects of surfactant on L-selectin-induced signal transduction in leukocytes. Using fluorescence microscopy, we provide evidence that preincubation of leukocytes with surfactant significantly inhibits receptor capping; 28+/-7% of cells show capping after L-selectin stimulation versus 8+/-5% and 3+/-1% of cells after preincubation with Exosurf and Curosurf, respectively (p < 0.05). The activity of the neutral sphingomyelinase in cell lysates is also modulated by surfactant. In addition, we show that the activation of the tyrosine kinase p56lck is diminished by approximately 50% after surfactant treatment. This results in inhibition in tyrosine phosphorylation of certain intracellular proteins. The interaction of the L-selectin molecule with its antibody was not influenced by surfactant as shown by flow cytometry. Surfactant inhibits intracellular signaling events of the L-selectin receptor in leukocytes and might therefore contribute to the modulatory effects of surfactant on immune function.
Collapse
|
45
|
Abstract
Leucocyte adhesion to endothelial cells is a tightly regulated process involving selectins, integrins and immunoglobulin-like proteins. Cell adhesion and communication are controlled by membrane dynamics like receptor capping. Capping of surface receptors is an ubiquitous mechanism but still not well understood. Employing immunofluorescence techniques, we demonstrate that L-selectin triggering results in receptor capping of the L-selectin molecules in lymphocytes. Using pharmacological inhibitors and genetic deficient cell lines we show that this process involves intracellular signalling molecules. L-Selectin capping seems to be independent on activation of p56lck-kinase, but requires the neutral sphingomyelinase, small G proteins and the cytoskeleton. Therefore, capping of L-selectin upon stimulation might play an important role in the very early phase of lymphocyte trafficking.
Collapse
|
46
|
[The relationship of maternal obesity, excessive weight gain in pregnancy and pre-eclampsia]. Geburtshilfe Frauenheilkd 1979; 39:1079-82. [PMID: 520790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
The records of 2,671 pregnancies were reviewed regarding maternal obesity, excessive weight gain in pregnancy and pre-eclampsia. Pre-eclampsia is significantly more frequent in maternal obesity. Correlation between excessive weight gain in pregnancy and pre-eclampsia is only found for the signs of edema and hypertension. Edema and excessive weight gain in pregnancy are related to each other, since edema frequently induces the excessive weight gain. Overall, maternal obesity perior to pregnancy is much more important in the development of pre-eclampsia than excessive weight gain during pregnancy.
Collapse
|