Impact of Device Implant Depth After Left Atrial Appendage Occlusion.
JACC Cardiovasc Interv 2023;
16:2139-2149. [PMID:
37565966 DOI:
10.1016/j.jcin.2023.05.045]
[Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 05/23/2023] [Accepted: 05/30/2023] [Indexed: 08/12/2023]
Abstract
BACKGROUND
Device-related thrombus (DRT) remains one of the main concerns after left atrial appendage occlusion (LAAO). Several risk factors have been proposed, but most cannot be modulated. A modifiable factor such as device implantation depth is a potential target to adjust the risk for DRT.
OBJECTIVES
The aim of this study was to assess the impact of LAAO device implantation depth as a predisposing factor for DRT.
METHODS
The study included patients who underwent successful LAAO at 9 centers in Europe and Canada. Patients were classified into 2 groups: proximal device implantation (covered pulmonary ridge [PR] in the lobe and disc cohort or <5 mm from the PR in the single-lobe cohort) and distal device implantation (uncovered PR in the disc and lobe cohort and ≥5 mm in the single-lobe cohort).
RESULTS
A total of 1,317 patients were included. Among these, proximal and distal device implantation was achieved in 732 (55%) and 585 (45%) patients, respectively. No differences in procedural outcomes were observed between the groups. At follow-up, patients with proximal implantation had a lower incidence of DRT (2.3%) than those with distal implantation (12.2%) (P < 0.001). Deeper device implantation and a larger uncovered left atrial appendage area were associated with a higher incidence of DRT (P < 0.001), regardless of device type. In multivariable analysis, distal implant (HR: 5.92; 95% CI: 3.39-10.36) and no or single antiplatelet therapy (HR: 1.62; 95% CI: 0.99-2.62) emerged as independent predictors of DRT.
CONCLUSIONS
LAAO device implantation depth is an independent risk factor for DRT. Deeper device implantation and larger uncovered left atrial appendage areas were associated with a higher incidence of DRT.
Collapse