1
|
Bravin A, Coan P, Suortti P. X-ray phase-contrast imaging: from pre-clinical applications towards clinics. Phys Med Biol 2012; 58:R1-35. [PMID: 23220766 DOI: 10.1088/0031-9155/58/1/r1] [Citation(s) in RCA: 400] [Impact Index Per Article: 30.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Phase-contrast x-ray imaging (PCI) is an innovative method that is sensitive to the refraction of the x-rays in matter. PCI is particularly adapted to visualize weakly absorbing details like those often encountered in biology and medicine. In past years, PCI has become one of the most used imaging methods in laboratory and preclinical studies: its unique characteristics allow high contrast 3D visualization of thick and complex samples even at high spatial resolution. Applications have covered a wide range of pathologies and organs, and are more and more often performed in vivo. Several techniques are now available to exploit and visualize the phase-contrast: propagation- and analyzer-based, crystal and grating interferometry and non-interferometric methods like the coded aperture. In this review, covering the last five years, we will give an overview of the main theoretical and experimental developments and of the important steps performed towards the clinical implementation of PCI.
Collapse
|
Review |
13 |
400 |
2
|
Arfelli F, Bonvicini V, Bravin A, Cantatore G, Castelli E, Palma LD, Michiel MD, Fabrizioli M, Longo R, Menk RH, Olivo A, Pani S, Pontoni D, Poropat P, Prest M, Rashevsky A, Ratti M, Rigon L, Tromba G, Vacchi A, Vallazza E, Zanconati F. Mammography with synchrotron radiation: phase-detection techniques. Radiology 2000; 215:286-93. [PMID: 10751500 DOI: 10.1148/radiology.215.1.r00ap10286] [Citation(s) in RCA: 132] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The authors evaluated the effect on mammographic examinations of the use of synchrotron radiation to detect phase-perturbation effects, which are higher than absorption effects for soft tissue in the energy range of 15-25 keV. Detection of phase-perturbation effects was possible because of the high degree of coherence of synchrotron radiation sources. Synchrotron radiation images were obtained of a mammographic phantom and in vitro breast tissue specimens and compared with conventional mammographic studies. On the basis of grades assigned by three reviewers, image quality of the former was considerably higher, and the delivered dose was fully compatible.
Collapse
|
Comparative Study |
25 |
132 |
3
|
Serduc R, Vérant P, Vial JC, Farion R, Rocas L, Rémy C, Fadlallah T, Brauer E, Bravin A, Laissue J, Blattmann H, van der Sanden B. In vivo two-photon microscopy study of short-term effects of microbeam irradiation on normal mouse brain microvasculature. Int J Radiat Oncol Biol Phys 2006; 64:1519-27. [PMID: 16580502 DOI: 10.1016/j.ijrobp.2005.11.047] [Citation(s) in RCA: 122] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2005] [Revised: 11/21/2005] [Accepted: 11/23/2005] [Indexed: 11/21/2022]
Abstract
PURPOSE The purpose of this study was to assess the early effects of microbeam irradiation on the vascular permeability and volume in the parietal cortex of normal nude mice using two-photon microscopy and immunohistochemistry. METHODS AND MATERIALS The upper part of the left hemisphere of 55 mice was irradiated anteroposteriorly using 18 vertically oriented beams (width 25 microm, interdistance 211 microm; peak entrance doses: 312 or 1000 Gy). At different times after microbeam exposure, the microvasculature in the cortex was analyzed using intravital two-photon microscopy after intravascular injection of fluorescein isothiocyanate (FITC)-dextrans and sulforhodamine B (SRB). Changes of the vascular volume were observed at the FITC wavelength over a maximum depth of 650 mum from the dura. The vascular permeability was detected as extravasations of SRB. RESULTS For all times (12 h to 1 month) after microbeam irradiation and for both doses, the FITC-dextran remained in the vessels. No significant change in vascular volume was observed between 12 h and 3 months after irradiation. Diffusion of SRB was observed in microbeam irradiated regions from 12 h until 12 days only after a 1000 Gy exposure. CONCLUSION No radiation damage to the microvasculature was detected in normal brain tissue after a 312 Gy microbeam irradiation. This dose would be more appropriate than 1000 Gy for the treatment of brain tumors using crossfired microbeams.
Collapse
|
|
19 |
122 |
4
|
Arfelli F, Assante M, Bonvicini V, Bravin A, Cantatore G, Castelli E, Dalla Palma L, Di Michiel M, Longo R, Olivo A, Pani S, Pontoni D, Poropat P, Prest M, Rashevsky A, Tromba G, Vacchi A, Vallazza E, Zanconati F. Low-dose phase contrast x-ray medical imaging. Phys Med Biol 1998; 43:2845-52. [PMID: 9814522 DOI: 10.1088/0031-9155/43/10/013] [Citation(s) in RCA: 105] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Phase contrast x-ray imaging is a powerful technique for the detection of low-contrast details in weakly absorbing objects. This method is of possible relevance in the field of diagnostic radiology. In fact, imaging low-contrast details within soft tissue does not give satisfactory results in conventional x-ray absorption radiology, mammography being a typical example. Nevertheless, up to now all applications of the phase contrast technique, carried out on thin samples, have required radiation doses substantially higher than those delivered in conventional radiological examinations. To demonstrate the applicability of the method to mammography we produced phase contrast images of objects a few centimetres thick while delivering radiation doses lower than or comparable to doses needed in standard mammographic examinations (typically approximately 1 mGy mean glandular dose (MGD)). We show images of a custom mammographic phantom and of two specimens of human breast tissue obtained at the SYRMEP bending magnet beamline at Elettra, the Trieste synchrotron radiation facility. The introduction of an intensifier screen enabled us to obtain phase contrast images of these thick samples with radiation doses comparable to those used in mammography. Low absorbing details such as 50 microm thick nylon wires or thin calcium deposits (approximately 50 microm) within breast tissue, invisible with conventional techniques, are detected by means of the proposed method. We also find that the use of a bending magnet radiation source relaxes the previously reported requirements on source size for phase contrast imaging. Finally, the consistency of the results has been checked by theoretical simulations carried out for the purposes of this experiment.
Collapse
|
|
27 |
105 |
5
|
Siegbahn EA, Stepanek J, Bräuer-Krisch E, Bravin A. Determination of dosimetrical quantities used in microbeam radiation therapy (MRT) with Monte Carlo simulations. Med Phys 2006; 33:3248-59. [PMID: 17022219 DOI: 10.1118/1.2229422] [Citation(s) in RCA: 102] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Microbeam radiation therapy (MRT) is being performed by using an array of narrow rectangular x-ray beams (typical beam sizes 25 microm X 1 cm), positioned close to each other (typically 200 microm separation), to irradiate a target tissue. The ratio of peak-to-valley doses (PVDR's) in the composite dose distribution has been found to be strongly correlated with the normal tissue tolerance and the therapeutic effect of MRT. In this work a Monte Carlo (MC) study of the depth- and lateral-dose profiles in water for single x-ray microbeams of different shapes and energies has been performed with the MC code PENELOPE. The contributions to the dose deposition from different interaction types have been determined at different distances from the center of the microbeam. The dependence of the peak dose, in a water phantom, on the microbeam field size used in the preclinical trials, has been demonstrated. Composite dose distributions for an array of microbeams were obtained using superposition algorithms and PVDR's were determined and compared with literature results obtained with other Monte Carlo codes. The dependence of the PVDR's on microbeam width, x-ray energy used, and on the separation between adjacent microbeams has been studied in detail.
Collapse
|
|
19 |
102 |
6
|
Serduc R, Bouchet A, Bräuer-Krisch E, Laissue JA, Spiga J, Sarun S, Bravin A, Fonta C, Renaud L, Boutonnat J, Siegbahn EA, Estève F, Le Duc G. Synchrotron microbeam radiation therapy for rat brain tumor palliation—influence of the microbeam width at constant valley dose. Phys Med Biol 2009; 54:6711-24. [DOI: 10.1088/0031-9155/54/21/017] [Citation(s) in RCA: 87] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
|
16 |
87 |
7
|
Pagot E, Fiedler S, Cloetens P, Bravin A, Coan P, Fezzaa K, Baruchel J, Härtwig J, von Smitten K, Leidenius M, Karjalainen-Lindsberg ML, Keyriläinen J. Quantitative comparison between two phase contrast techniques: diffraction enhanced imaging and phase propagation imaging. Phys Med Biol 2005; 50:709-24. [PMID: 15773629 DOI: 10.1088/0031-9155/50/4/010] [Citation(s) in RCA: 86] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Two x-ray phase contrast imaging techniques are compared in a quantitative way for future mammographic applications: diffraction enhanced imaging (DEI) and phase propagation imaging (PPI). DEI involves, downstream of the sample, an analyser crystal acting as an angular filter for x-rays refracted by the sample. PPI simply uses the propagation (Fresnel diffraction) of the monochromatic and partially coherent x-ray beam over large distances. The information given by the two techniques is assessed by theoretical simulations and compared at the level of the experimental results for different kinds of samples (phantoms and real tissues). The imaging parameters such as the energy, the angular position of the analyser crystal in the DEI case or the sample to detector distance in the PPI case were varied in order to optimize the image quality in terms of contrast, visibility and figure of merit.
Collapse
|
|
20 |
86 |
8
|
Bräuer-Krisch E, Bravin A, Lerch M, Rosenfeld A, Stepanek J, Di Michiel M, Laissue JA. MOSFET dosimetry for microbeam radiation therapy at the European Synchrotron Radiation Facility. Med Phys 2003; 30:583-9. [PMID: 12722810 DOI: 10.1118/1.1562169] [Citation(s) in RCA: 86] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Preclinical experiments are carried out with approximately 20-30 microm wide, approximately 10 mm high parallel microbeams of hard, broad-"white"-spectrum x rays (approximately 50-600 keV) to investigate microbeam radiation therapy (MRT) of brain tumors in infants for whom other kinds of radiotherapy are inadequate and/or unsafe. Novel physical microdosimetry (implemented with MOSFET chips in the "edge-on" mode) and Monte Carlo computer-simulated dosimetry are described here for selected points in the peak and valley regions of a microbeam-irradiated tissue-equivalent phantom. Such microbeam irradiation causes minimal damage to normal tissues, possible because of rapid repair of their microscopic lesions. Radiation damage from an array of parallel microbeams tends to correlate with the range of peak-valley dose ratios (PVDR). This paper summarizes comparisons of our dosimetric MOSFET measurements with Monte Carlo calculations. Peak doses at depths <22 mm are 18% less than Monte Carlo values, whereas those depths >22 mm and valley doses at all depths investigated (2 mm-62 mm) are within 2-13% of the Monte Carlo values. These results lend credence to the use of MOSFET detector systems in edge-on mode for microplanar irradiation dosimetry.
Collapse
|
Comparative Study |
22 |
86 |
9
|
Bravin A, Keyriläinen J, Fernández M, Fiedler S, Nemoz C, Karjalainen-Lindsberg ML, Tenhunen M, Virkkunen P, Leidenius M, von Smitten K, Sipilä P, Suortti P. High-resolution CT by diffraction-enhanced x-ray imaging: mapping of breast tissue samples and comparison with their histo-pathology. Phys Med Biol 2007; 52:2197-211. [PMID: 17404464 DOI: 10.1088/0031-9155/52/8/011] [Citation(s) in RCA: 86] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The aim of this study was to introduce high-resolution computed tomography (CT) of breast tumours using the diffraction-enhanced x-ray imaging (DEI) technique and to compare results with radiological and histo-pathological examinations. X-ray CT images of tumour-bearing breast tissue samples were acquired by monochromatic synchrotron radiation (SR). Due to the narrow beam and a large sample-to-detector distance scattering is rejected in the absorption contrast images (SR-CT). Large contrast enhancement is achieved by the use of the DEI-CT method, where the effects of refraction and scatter rejection are analysed by crystal optics. Clinical mammograms and CT images were recorded as reference material for a radiological examination. Three malignant and benign samples were studied in detail. Their radiographs were compared with optical images of stained histological sections. The DEI-CT images map accurately the morphology of the samples, including collagen strands and micro-calcifications of dimensions less than 0.1 mm. Histo-pathological examination and reading of the radiographs were done independently, and the conclusions were in general agreement. High-resolution DEI-CT images show strong contrast and permit visualization of details invisible in clinical radiographs. The radiation dose may be reduced by an order of magnitude without compromising image quality, which would make possible clinical in vivo DEI-CT with future compact SR sources.
Collapse
|
Research Support, Non-U.S. Gov't |
18 |
86 |
10
|
Regnard P, Duc GL, Bräuer-Krisch E, Troprès I, Siegbahn EA, Kusak A, Clair C, Bernard H, Dallery D, Laissue JA, Bravin A. Irradiation of intracerebral 9L gliosarcoma by a single array of microplanar x-ray beams from a synchrotron: balance between curing and sparing. Phys Med Biol 2008; 53:861-78. [DOI: 10.1088/0031-9155/53/4/003] [Citation(s) in RCA: 83] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
|
17 |
83 |
11
|
Fiedler S, Bravin A, Keyriläinen J, Fernández M, Suortti P, Thomlinson W, Tenhunen M, Virkkunen P, Karjalainen-Lindsberg M. Imaging lobular breast carcinoma: comparison of synchrotron radiation DEI-CT technique with clinical CT, mammography and histology. Phys Med Biol 2004; 49:175-88. [PMID: 15083665 DOI: 10.1088/0031-9155/49/2/001] [Citation(s) in RCA: 80] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Different modalities for imaging cancer-bearing breast tissue samples are described and compared. The images include clinical mammograms and computed tomography (CT) images, CT images with partly coherent synchrotron radiation (SR), and CT and radiography images taken with SR using the diffraction enhanced imaging (DEI) method. The images are evaluated by a radiologist and compared with histopathological examination of the samples. Two cases of lobular carcinoma are studied in detail. The indications of cancer are very weak or invisible in the conventional images, but the morphological changes due to invasion of cancer become pronounced in the images taken by the DEI method. The strands penetrating adipose tissue are seen clearly in the DEI-CT images, and the histopathology confirms that some strands contain the so-called 'Indian file' formations of cancer cells. The radiation dose is carefully measured for each of the imaging modalities. The mean glandular dose (MGD) for 50% glandular breast tissue is about 1 mGy in conventional mammography and less than 0.25 mGy in projection DEI, while in the clinical CT imaging the MGD is very high, about 45 mGy. The entrance dose of 95 mGy in DEI-CT imaging gives rise to an MGD of 40 mGy, but the dose may be reduced by an order of magnitude, because the contrast is very large in most images.
Collapse
|
Research Support, Non-U.S. Gov't |
21 |
80 |
12
|
Serduc R, van de Looij Y, Francony G, Verdonck O, van der Sanden B, Laissue J, Farion R, Bräuer-Krisch E, Siegbahn EA, Bravin A, Prezado Y, Segebarth C, Rémy C, Lahrech H. Characterization and quantification of cerebral edema induced by synchrotron x-ray microbeam radiation therapy. Phys Med Biol 2008; 53:1153-66. [DOI: 10.1088/0031-9155/53/5/001] [Citation(s) in RCA: 78] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
|
17 |
78 |
13
|
Miura M, Blattmann H, Bräuer-Krisch E, Bravin A, Hanson AL, Nawrocky MM, Micca PL, Slatkin DN, Laissue JA. Radiosurgical palliation of aggressive murine SCCVII squamous cell carcinomas using synchrotron-generated X-ray microbeams. Br J Radiol 2006; 79:71-5. [PMID: 16421408 DOI: 10.1259/bjr/50464795] [Citation(s) in RCA: 75] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Microbeam radiosurgery (MBRS), also referred to as microbeam radiation therapy (MRT), was tested at the European Synchrotron Radiation Facility (ESRF). The left tibiofibular thigh of a mouse bearing a subcutaneously (sc) implanted mouse model (SCCVII) of aggressive human squamous-cell carcinoma was irradiated in two orthogonal exposures with or without a 16 mm aluminium filter through a multislit collimator (MSC) by arrays of nearly parallel microbeams spaced 200 microm on centre (oc). The peak skin-entrance dose from each exposure was 442 Gy, 625 Gy, or 884 Gy from 35 microm wide beams or 442 Gy from 70 microm wide beams. The 442/35, 625/35, 884/35 and 442/70 MBRSs yielded 25 day, 29 day, 37 day and 35 day median survival times (MST) (post-irradiation), respectively, exceeding the 20 day MST from 35 Gy-irradiation of SCCVIIs with a seamless 100 kVp X-ray beam.
Collapse
|
|
19 |
75 |
14
|
Smilowitz HM, Blattmann H, Bräuer-Krisch E, Bravin A, Di Michiel M, Gebbers JO, Hanson AL, Lyubimova N, Slatkin DN, Stepanek J, Laissue JA. Synergy of gene-mediated immunoprophylaxis and microbeam radiation therapy for advanced intracerebral rat 9L gliosarcomas. J Neurooncol 2006; 78:135-43. [PMID: 16598429 DOI: 10.1007/s11060-005-9094-9] [Citation(s) in RCA: 75] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2005] [Accepted: 12/06/2005] [Indexed: 11/30/2022]
Abstract
PURPOSE Microbeam radiation therapy (MRT), a novel experimental radiosurgery that largely spares the developing CNS and other normal tissues, is tolerated well by developing animals and palliates advanced 9LGS tumors. This report, to our knowledge, is the first demonstration that gene-mediated immunotherapy (GMIMPR) enhances the efficacy of MRT for advanced 9LGS tumors. METHODS Seventy-six male Fischer 344 rats were implanted ic with 10(4)9LGS cells on d0. By d14, the cells had generated approximately approximately 40 mm3 ic 9LGS tumours, experimental models for therapy of moderately aggressive human malignant astrocytomas. Each of the 14 untreated (control) rats died from a large (>100 mg) ic tumor before d29 (median, d21). On d14, the remaining 62 rats were given deliberately suboptimal microbeam radiation therapy (MRT) by a single lateral exposure of the tumor-bearing zone of the head to a 10.1 mm-wide, approximately approximately 11 mm-high array of 20-39 microm-wide, nearly parallel beams of synchrotron wiggler-generated radiation (mainly approximately 50-150 keV X-rays) that delivered 625 Gy peak skin doses at approximately approximately 211 microm ctc intervals in approximately approximately 300 ms either without additional treatments (MRT-only, 25 rats), with post-MRT GMIMPR (MRT+GMIMPR, 23 rats: multiple sc injections of irradiated (clonogenically-disabled) GM-CSF gene-transfected 9LGS cells), or with post-MRT IMPR (MRT+IMPR, 14 rats: multiple sc injections of irradiated (clonogenically-disabled) 9LGS cells. RESULTS The median post-implantation survivals of rats in the MRT-only, MRT+GMIMPR and MRT+IMPR groups were over twice that of controls; further, approximately approximately 20% of rats in MRT-only and MRT+IMPR groups survived >1 yr with no obvious disabilities. Moreover, over 40% of MRT+GMIMPR rats survived >1 yr with no obvious disabilities, a significant (P<0.04) increase over the MRT-only and MRT+IMPR groups. SIGNIFICANCE These data suggest that the combination of MRT+GMIMPR might be better than MRT only for unifocal CNS tumors, particularly in infants and young children.
Collapse
|
Journal Article |
19 |
75 |
15
|
Bräuer-Krisch E, Requardt H, Brochard T, Berruyer G, Renier M, Laissue JA, Bravin A. New technology enables high precision multislit collimators for microbeam radiation therapy. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2009; 80:074301. [PMID: 19655968 DOI: 10.1063/1.3170035] [Citation(s) in RCA: 73] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
During the past decade microbeam radiation therapy has evolved from preclinical studies to a stage in which clinical trials can be planned, using spatially fractionated, highly collimated and high intensity beams like those generated at the x-ray ID17 beamline of the European Synchrotron Radiation Facility. The production of such microbeams typically between 25 and 100 microm full width at half maximum (FWHM) values and 100-400 microm center-to-center (c-t-c) spacings requires a multislit collimator either with fixed or adjustable microbeam width. The mechanical regularity of such devices is the most important property required to produce an array of identical microbeams. That ensures treatment reproducibility and reliable use of Monte Carlo-based treatment planning systems. New high precision wire cutting techniques allow the fabrication of these collimators made of tungsten carbide. We present a variable slit width collimator as well as a single slit device with a fixed setting of 50 microm FWHM and 400 microm c-t-c, both able to cover irradiation fields of 50 mm width, deemed to meet clinical requirements. Important improvements have reduced the standard deviation of 5.5 microm to less than 1 microm for a nominal FWHM value of 25 microm. The specifications of both devices, the methods used to measure these characteristics, and the results are presented.
Collapse
|
|
16 |
73 |
16
|
Bräuer-Krisch E, Requardt H, Régnard P, Corde S, Siegbahn E, LeDuc G, Brochard T, Blattmann H, Laissue J, Bravin A. New irradiation geometry for microbeam radiation therapy. Phys Med Biol 2005; 50:3103-11. [PMID: 15972983 DOI: 10.1088/0031-9155/50/13/009] [Citation(s) in RCA: 72] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Microbeam radiation therapy (MRT) has the potential to treat infantile brain tumours when other kinds of radiotherapy would be excessively toxic to the developing normal brain. MRT uses extraordinarily high doses of x-rays but provides unusual resistance to radioneurotoxicity, presumably from the migration of endothelial cells from 'valleys' into 'peaks', i.e., into directly irradiated microslices of tissues. We present a novel irradiation geometry which results in a tolerable valley dose for the normal tissue and a decreased peak-to-valley dose ratio (PVDR) in the tumour area by applying an innovative cross-firing technique. We propose an MRT technique to orthogonally crossfire two arrays of parallel, nonintersecting, mutually interspersed microbeams that produces tumouricidal doses with small PVDRs where the arrays meet and tolerable radiation doses to normal tissues between the microbeams proximal and distal to the tumour in the paths of the arrays.
Collapse
|
|
20 |
72 |
17
|
Keyriläinen J, Bravin A, Fernández M, Tenhunen M, Virkkunen P, Suortti P. Phase-contrast X-ray imaging of breast. Acta Radiol 2010; 51:866-84. [PMID: 20799921 DOI: 10.3109/02841851.2010.504742] [Citation(s) in RCA: 72] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
When an X-ray wave traverses an object, its amplitude and phase change, resulting in attenuation, interference, and refraction, and in phase-contrast X-ray imaging (PCI) these are converted to intensity changes. The relative change of the X-ray phase per unit path length is even orders of magnitude larger than that of the X-ray amplitude, so that the image contrast based on variation of the X-ray phase is potentially much stronger than the contrast based on X-ray amplitude (absorption contrast). An important medical application of PCI methods is soft-tissue imaging, where the absorption contrast is inherently weak. It is shown by in vitro examples that signs of malignant human breast tumor are enhanced in PCI images. Owing to the strong contrast, the radiation dose can be greatly reduced, so that a high-resolution phase-contrast X-ray tomography of the breast is possible with about 1 mGy mean glandular dose. Scattered radiation carries essential information on the atomic and molecular structure of the object, and particularly small-angle X-ray scattering can be used to trace cancer. The imaging methods developed at the synchrotron radiation facilities will become available in the clinical environment with the ongoing development of compact radiation sources, which produce intense X-ray beams of sufficient coherence. Several developments that are under way are described here.
Collapse
|
Journal Article |
15 |
72 |
18
|
Serduc R, Christen T, Laissue J, Farion R, Bouchet A, Sanden BVD, Segebarth C, Bräuer-Krisch E, Le Duc G, Bravin A, Rémy C, Barbier EL. Brain tumor vessel response to synchrotron microbeam radiation therapy: a short-termin vivostudy. Phys Med Biol 2008; 53:3609-22. [DOI: 10.1088/0031-9155/53/13/015] [Citation(s) in RCA: 65] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
|
17 |
65 |
19
|
Fratini M, Bukreeva I, Campi G, Brun F, Tromba G, Modregger P, Bucci D, Battaglia G, Spanò R, Mastrogiacomo M, Requardt H, Giove F, Bravin A, Cedola A. Simultaneous submicrometric 3D imaging of the micro-vascular network and the neuronal system in a mouse spinal cord. Sci Rep 2015; 5:8514. [PMID: 25686728 PMCID: PMC4649670 DOI: 10.1038/srep08514] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2014] [Accepted: 01/19/2015] [Indexed: 11/25/2022] Open
Abstract
Faults in vascular (VN) and neuronal networks of spinal cord are responsible for serious neurodegenerative pathologies. Because of inadequate investigation tools, the lacking knowledge of the complete fine structure of VN and neuronal system represents a crucial problem. Conventional 2D imaging yields incomplete spatial coverage leading to possible data misinterpretation, whereas standard 3D computed tomography imaging achieves insufficient resolution and contrast. We show that X-ray high-resolution phase-contrast tomography allows the simultaneous visualization of three-dimensional VN and neuronal systems of ex-vivo mouse spinal cord at scales spanning from millimeters to hundreds of nanometers, with nor contrast agent nor sectioning and neither destructive sample-preparation. We image both the 3D distribution of micro-capillary network and the micrometric nerve fibers, axon-bundles and neuron soma. Our approach is very suitable for pre-clinical investigation of neurodegenerative pathologies and spinal-cord-injuries, in particular to resolve the entangled relationship between VN and neuronal system.
Collapse
|
Research Support, Non-U.S. Gov't |
10 |
61 |
20
|
Fernández M, Keyriläinen J, Serimaa R, Torkkeli M, Karjalainen-Lindsberg ML, Leidenius M, von Smitten K, Tenhunen M, Fiedler S, Bravin A, Weiss TM, Suortti P. Human breast cancerin vitro: matching histo-pathology with small-angle x-ray scattering and diffraction enhanced x-ray imaging. Phys Med Biol 2005; 50:2991-3006. [PMID: 15972976 DOI: 10.1088/0031-9155/50/13/002] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Twenty-eight human breast tumour specimens were studied with small-angle x-ray scattering (SAXS), and 10 of those were imaged by the diffraction enhanced x-ray imaging (DEI) technique. The sample diameter was 20 mm and the thickness 1 mm. Two examples of ductal carcinoma are illustrated by histology images, DEI, and maps of the collagen d-spacing and scattered intensity in the Porod regime, which characterize the SAXS patterns from collagen-rich regions of the samples. Histo-pathology reveals the cancer-invaded regions, and the maps of the SAXS parameters show that in these regions the scattering signal differs significantly from scattering by the surrounding tissue, indicating a degradation of the collagen structure in the invaded regions. The DEI images show the borders between collagen and adipose tissue and provide a co-ordinate system for tissue mapping by SAXS. In addition, degradation of the collagen structure in an invaded region is revealed by fading contrast of the DEI refraction image. The 28 samples include fresh, defrosted tissue and formalin-fixed tissue. The d-values with their standard deviations are given. In the fresh samples there is a systematic 0.76% increase of the d-value in the invaded regions, averaged over 11 samples. Only intra-sample comparisons are made for the formalin-fixed samples, and with a long fixation time, the difference in the d-value stabilizes at about 0.7%. The correspondence between the DEI images, the SAXS maps and the histo-pathology suggests that definitive information on tumour growth and malignancy is obtained by combining these x-ray methods.
Collapse
|
|
20 |
58 |
21
|
Horng A, Brun E, Mittone A, Gasilov S, Weber L, Geith T, Adam-Neumair S, Auweter SD, Bravin A, Reiser MF, Coan P. Cartilage and Soft Tissue Imaging Using X-rays. Invest Radiol 2014; 49:627-34. [DOI: 10.1097/rli.0000000000000063] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
|
11 |
58 |
22
|
Keyriläinen J, Fernández M, Karjalainen-Lindsberg ML, Virkkunen P, Leidenius M, von Smitten K, Sipilä P, Fiedler S, Suhonen H, Suortti P, Bravin A. Toward High-Contrast Breast CT at Low Radiation Dose. Radiology 2008; 249:321-7. [PMID: 18796684 DOI: 10.1148/radiol.2491072129] [Citation(s) in RCA: 58] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
|
17 |
58 |
23
|
Coan P, Peterzol A, Fiedler S, Ponchut C, Labiche JC, Bravin A. Evaluation of imaging performance of a taper optics CCD; FReLoN' camera designed for medical imaging. JOURNAL OF SYNCHROTRON RADIATION 2006; 13:260-70. [PMID: 16645252 DOI: 10.1107/s0909049506008983] [Citation(s) in RCA: 56] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2005] [Accepted: 03/09/2006] [Indexed: 05/08/2023]
Abstract
The purpose of this work was to assess the imaging performance of an indirect conversion detector (taper optics CCD; FReLoN' camera) in terms of the modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE). Measurements were made with a synchrotron radiation laminar beam at various monochromatic energies in the 20-51.5 keV range for a gadolinium-based fluorescent screen varying in thickness; data acquisition and analysis were made by adapting to this beam geometry protocols used for conventional cone beams. The pre-sampled MTFs of the systems were measured using an edge method. The NNPS of the systems were determined for a range of exposure levels by two-dimensional Fourier analysis of uniformly exposed radiographs. The DQEs were assessed from the measured MTF, NNPS, exposure and incoming number of photons. The MTF, for a given screen, was found to be almost energy independent and, for a given energy, higher for the thinnest screen. At 33 keV and for the 40 (100) microm screen, at 10% the MTF is 9.2 (8.6) line-pairs mm(-1). The NNPS was found to be different in the two analyzed directions in relation to frequency. Highest DQE values were found for the combination 100 microm and 25 keV (0.5); it was still equal to 0.4 at 51.5 keV (above the gadolinium K-edge). The DQE is limited by the phosphor screen conversion yield and by the CCD efficiency. At the end of the manuscript the results of the FReLoN characterization and those from a selected number of detectors presented in the literature are compared.
Collapse
|
Evaluation Study |
19 |
56 |
24
|
Sztrókay A, Diemoz PC, Schlossbauer T, Brun E, Bamberg F, Mayr D, Reiser MF, Bravin A, Coan P. High-resolution breast tomography at high energy: a feasibility study of phase contrast imaging on a whole breast. Phys Med Biol 2012; 57:2931-42. [PMID: 22516937 DOI: 10.1088/0031-9155/57/10/2931] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Previous studies on phase contrast imaging (PCI) mammography have demonstrated an enhancement of breast morphology and cancerous tissue visualization compared to conventional imaging. We show here the first results of the PCI analyser-based imaging (ABI) in computed tomography (CT) mode on whole and large (>12 cm) tumour-bearing breast tissues. We demonstrate in this work the capability of the technique of working at high x-ray energies and producing high-contrast images of large and complex specimens. One entire breast of an 80-year-old woman with invasive ductal cancer was imaged using ABI-CT with monochromatic 70 keV x-rays and an area detector of 92×92 µm² pixel size. Sagittal slices were reconstructed from the acquired data, and compared to corresponding histological sections. Comparison with conventional absorption-based CT was also performed. Five blinded radiologists quantitatively evaluated the visual aspects of the ABI-CT images with respect to sharpness, soft tissue contrast, tissue boundaries and the discrimination of different structures/tissues. ABI-CT excellently depicted the entire 3D architecture of the breast volume by providing high-resolution and high-contrast images of the normal and cancerous breast tissues. These results are an important step in the evolution of PCI-CT towards its clinical implementation.
Collapse
|
Research Support, Non-U.S. Gov't |
13 |
54 |
25
|
Sabatasso S, Laissue JA, Hlushchuk R, Graber W, Bravin A, Bräuer-Krisch E, Corde S, Blattmann H, Gruber G, Djonov V. Microbeam radiation-induced tissue damage depends on the stage of vascular maturation. Int J Radiat Oncol Biol Phys 2011; 80:1522-32. [PMID: 21740994 DOI: 10.1016/j.ijrobp.2011.03.018] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2010] [Revised: 02/21/2011] [Accepted: 03/20/2011] [Indexed: 10/18/2022]
Abstract
PURPOSE To explore the effects of microbeam radiation (MR) on vascular biology, we used the chick chorioallantoic membrane (CAM) model of an almost pure vascular system with immature vessels (lacking periendothelial coverage) at Day 8 and mature vessels (with coverage) at Day 12 of development. METHODS AND MATERIALS CAMs were irradiated with microplanar beams (width, ∼25 μm; interbeam spacing, ∼200 μm) at entrance doses of 200 or 300 Gy and, for comparison, with a broad beam (seamless radiation [SLR]), with entrance doses of 5 to 40 Gy. RESULTS In vivo monitoring of Day-8 CAM vasculature 6 h after 200 Gy MR revealed a near total destruction of the immature capillary plexus. Conversely, 200 Gy MR barely affected Day-12 CAM mature microvasculature. Morphological evaluation of Day-12 CAMs after the dose was increased to 300 Gy revealed opened interendothelial junctions, which could explain the transient mesenchymal edema immediately after irradiation. Electron micrographs revealed cytoplasmic vacuolization of endothelial cells in the beam path, with disrupted luminal surfaces; often the lumen was engorged with erythrocytes and leukocytes. After 30 min, the capillary plexus adopted a striated metronomic pattern, with alternating destroyed and intact zones, corresponding to the beam and the interbeam paths within the array. SLR at a dose of 10 Gy caused growth retardation, resulting in a remarkable reduction in the vascular endpoint density 24 h postirradiation. A dose of 40 Gy damaged the entire CAM vasculature. CONCLUSIONS The effects of MR are mediated by capillary damage, with tissue injury caused by insufficient blood supply. Vascular toxicity and physiological effects of MR depend on the stage of capillary maturation and appear in the first 15 to 60 min after irradiation. Conversely, the effects of SLR, due to the arrest of cell proliferation, persist for a longer time.
Collapse
|
Research Support, Non-U.S. Gov't |
14 |
54 |