1
|
Chan RH, Maron BJ, Olivotto I, Pencina MJ, Assenza GE, Haas T, Lesser JR, Gruner C, Crean AM, Rakowski H, Udelson JE, Rowin E, Lombardi M, Cecchi F, Tomberli B, Spirito P, Formisano F, Biagini E, Rapezzi C, De Cecco CN, Autore C, Cook EF, Hong SN, Gibson CM, Manning WJ, Appelbaum E, Maron MS. Prognostic value of quantitative contrast-enhanced cardiovascular magnetic resonance for the evaluation of sudden death risk in patients with hypertrophic cardiomyopathy. Circulation 2014; 130:484-95. [PMID: 25092278 DOI: 10.1161/circulationaha.113.007094] [Citation(s) in RCA: 729] [Impact Index Per Article: 66.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND Hypertrophic cardiomyopathy (HCM) is the most common cause of sudden death in the young, although not all patients eligible for sudden death prevention with an implantable cardioverter-defibrillator are identified. Contrast-enhanced cardiovascular magnetic resonance with late gadolinium enhancement (LGE) has emerged as an in vivo marker of myocardial fibrosis, although its role in stratifying sudden death risk in subgroups of HCM patients remains incompletely understood. METHODS AND RESULTS We assessed the relation between LGE and cardiovascular outcomes in 1293 HCM patients referred for cardiovascular magnetic resonance and followed up for a median of 3.3 years. Sudden cardiac death (SCD) events (including appropriate defibrillator interventions) occurred in 37 patients (3%). A continuous relationship was evident between LGE by percent left ventricular mass and SCD event risk in HCM patients (P=0.001). Extent of LGE was associated with an increased risk of SCD events (adjusted hazard ratio, 1.46/10% increase in LGE; P=0.002), even after adjustment for other relevant disease variables. LGE of ≥15% of LV mass demonstrated a 2-fold increase in SCD event risk in those patients otherwise considered to be at lower risk, with an estimated likelihood for SCD events of 6% at 5 years. Performance of the SCD event risk model was enhanced by LGE (net reclassification index, 12.9%; 95% confidence interval, 0.3-38.3). Absence of LGE was associated with lower risk for SCD events (adjusted hazard ratio, 0.39; P=0.02). Extent of LGE also predicted the development of end-stage HCM with systolic dysfunction (adjusted hazard ratio, 1.80/10% increase in LGE; P<0.03). CONCLUSIONS Extensive LGE measured by quantitative contrast enhanced CMR provides additional information for assessing SCD event risk among HCM patients, particularly patients otherwise judged to be at low risk.
Collapse
|
Randomized Controlled Trial |
11 |
729 |
2
|
Bergersen L, Benson LN, Gillespie MJ, Cheatham SL, Crean AM, Hor KN, Horlick EM, Lung TH, McHenry BT, Osten MD, Powell AJ, Cheatham JP. Harmony Feasibility Trial: Acute and Short-Term Outcomes With a Self-Expanding Transcatheter Pulmonary Valve. JACC Cardiovasc Interv 2018; 10:1763-1773. [PMID: 28882284 DOI: 10.1016/j.jcin.2017.05.034] [Citation(s) in RCA: 108] [Impact Index Per Article: 15.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2016] [Revised: 04/17/2017] [Accepted: 05/21/2017] [Indexed: 12/13/2022]
Abstract
OBJECTIVES This study sought to obtain in vivo data to confirm assumptions on device loading conditions and assess procedural feasibility, safety, and valve performance. BACKGROUND The Harmony transcatheter pulmonary valve (Medtronic, Minneapolis, Minnesota) was designed for patients with severe pulmonary regurgitation who require pulmonary valve replacement. METHODS Three sites participated in this first Food and Drug Administration-approved early feasibility study using an innovative device design to accommodate the complex anatomy of the right ventricular outflow tract. Potentially eligible patients underwent review by a screening committee to determine implant eligibility. Six-month outcomes are reported. RESULTS Between May 2013 and May 2015, 66 subjects were enrolled, and 21 were approved for implant and underwent catheterization; 20 were implanted. Catheterized patients had a median age of 25 years, were predominantly diagnosed with tetralogy of Fallot (95%), had severe pulmonary regurgitation (95%), and had trivial or mild stenosis. The device was delivered in the desired location in 19 of 20 (95%) patients. Proximal migration occurred in 1 patient during delivery system removal. Two devices were surgically explanted. Premature ventricular contractions related to the procedure were reported in 3 patients; 2 were resolved without treatment. One patient had ventricular arrhythmias that required treatment and later were resolved. At 1 month, echocardiography revealed none or trivial pulmonary regurgitation in all and a mean right ventricular outflow tract gradient of 16 ± 8 mm Hg (range 6 to 31 mm Hg). CONCLUSIONS In this feasibility study of the Harmony transcatheter pulmonary valve device, there was high procedural success and safety, and favorable acute device performance.
Collapse
|
Research Support, Non-U.S. Gov't |
7 |
108 |
3
|
Han BK, Rigsby CK, Leipsic J, Bardo D, Abbara S, Ghoshhajra B, Lesser JR, Raman SV, Crean AM, Nicol ED, Siegel MJ, Hlavacek A. Computed Tomography Imaging in Patients with Congenital Heart Disease, Part 2: Technical Recommendations. An Expert Consensus Document of the Society of Cardiovascular Computed Tomography (SCCT). J Cardiovasc Comput Tomogr 2015; 9:493-513. [DOI: 10.1016/j.jcct.2015.07.007] [Citation(s) in RCA: 87] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/23/2015] [Accepted: 07/17/2015] [Indexed: 02/06/2023]
|
|
10 |
87 |
4
|
Crean AM, Maredia N, Ballard G, Menezes R, Wharton G, Forster J, Greenwood JP, Thomson JD. 3D Echo systematically underestimates right ventricular volumes compared to cardiovascular magnetic resonance in adult congenital heart disease patients with moderate or severe RV dilatation. J Cardiovasc Magn Reson 2011; 13:78. [PMID: 22152255 PMCID: PMC3283510 DOI: 10.1186/1532-429x-13-78] [Citation(s) in RCA: 85] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2011] [Accepted: 12/08/2011] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND Three dimensional echo is a relatively new technique which may offer a rapid alternative for the examination of the right heart. However its role in patients with non-standard ventricular size or anatomy is unclear. This study compared volumetric measurements of the right ventricle in 25 patients with adult congenital heart disease using both cardiovascular magnetic resonance (CMR) and three dimensional echocardiography. METHODS Patients were grouped by diagnosis into those expected to have normal or near-normal RV size (patients with repaired coarctation of the aorta) and patients expected to have moderate or worse RV enlargement (patients with repaired tetralogy of Fallot or transposition of the great arteries). Right ventricular end diastolic volume, end systolic volume and ejection fraction were compared using both methods with CMR regarded as the reference standard RESULTS Bland-Altman analysis of the 25 patients demonstrated that for both RV EDV and RV ESV, there was a significant and systematic under-estimation of volume by 3D echo compared to CMR. This bias led to a mean underestimation of RV EDV by -34% (95%CI: -91% to + 23%). The degree of underestimation was more marked for RV ESV with a bias of -42% (95%CI: -117% to + 32%). There was also a tendency to overestimate RV EF by 3D echo with a bias of approximately 13% (95% CI -52% to +27%). CONCLUSIONS Statistically significant and clinically meaningful differences in volumetric measurements were observed between the two techniques. Three dimensional echocardiography does not appear ready for routine clinical use in RV assessment in congenital heart disease patients with more than mild RV dilatation at the current time.
Collapse
|
Comparative Study |
14 |
85 |
5
|
Karur GR, Robison S, Iwanochko RM, Morel CF, Crean AM, Thavendiranathan P, Nguyen ET, Mathur S, Wasim S, Hanneman K. Use of Myocardial T1 Mapping at 3.0 T to Differentiate Anderson-Fabry Disease from Hypertrophic Cardiomyopathy. Radiology 2018; 288:398-406. [PMID: 29688154 DOI: 10.1148/radiol.2018172613] [Citation(s) in RCA: 59] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Purpose To compare left ventricular (LV) and right ventricular (RV) 3.0-T cardiac magnetic resonance (MR) imaging T1 values in Anderson-Fabry disease (AFD) and hypertrophic cardiomyopathy (HCM) and evaluate the diagnostic value of native T1 values beyond age, sex, and conventional imaging features. Materials and Methods For this prospective study, 30 patients with gene-positive AFD (37% male; mean age ± standard deviation, 45.0 years ± 14.1) and 30 patients with HCM (57% male; mean age, 49.3 years ± 13.5) were prospectively recruited between June 2016 and September 2017 to undergo cardiac MR imaging T1 mapping with a modified Look-Locker inversion recovery (MOLLI) acquisition scheme at 3.0 T (repetition time msec/echo time msec, 280/1.12; section thickness, 8 mm). LV and RV T1 values were evaluated. Statistical analysis included independent samples t test, receiver operating characteristic curve analysis, multivariable logistic regression, and likelihood ratio test. Results Septal LV, global LV, and RV native T1 values were significantly lower in AFD compared with those in HCM (1161 msec ± 47 vs 1296 msec ± 55, respectively [P < .001]; 1192 msec ± 52 vs 1268 msec ± 55 [P < .001]; and 1221 msec ± 54 vs 1271 msec ± 37 [P = .001], respectively). A septal LV native T1 cutoff point of 1220 msec or lower distinguished AFD from HCM with sensitivity of 97%, specificity of 93%, and accuracy of 95%. Septal LV native T1 values differentiated AFD from HCM after adjustment for age, sex, and conventional imaging features (odds ratio, 0.94; 95% confidence interval: 0.91, 0.98; P = < .001). In a nested logistic regression model with age, sex, and conventional imaging features, model fit was significantly improved by the addition of septal LV native T1 values (χ2 [df = 1] = 33.4; P < .001). Conclusion Cardiac MR imaging native T1 values at 3.0 T are significantly lower in patients with AFD compared with those with HCM and provide independent and incremental diagnostic value beyond age, sex, and conventional imaging features. © RSNA, 2018.
Collapse
|
Journal Article |
7 |
59 |
6
|
Yalonetsky S, Tobler D, Greutmann M, Crean AM, Wintersperger BJ, Nguyen ET, Oechslin EN, Silversides CK, Wald RM. Cardiac magnetic resonance imaging and the assessment of ebstein anomaly in adults. Am J Cardiol 2011; 107:767-73. [PMID: 21247528 DOI: 10.1016/j.amjcard.2010.10.058] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/15/2010] [Revised: 10/13/2010] [Accepted: 10/19/2010] [Indexed: 11/29/2022]
Abstract
No published studies have evaluated the role of cardiac magnetic resonance (CMR) imaging for the assessment of Ebstein anomaly. Our objective was to evaluate the right heart characteristics in adults with unrepaired Ebstein anomaly using contemporary CMR imaging techniques. Consecutive patients with unrepaired Ebstein anomaly and complete CMR studies from 2004 to 2009 were identified (n = 32). Volumetric measurements were obtained from the short-axis and axial views, including assessment of the functional right ventricular (RV) end-diastolic volume (EDV) and end-systolic volume. The volume of the atrialized portion of the right ventricle in end-diastole was calculated as the difference between the total RVEDV and the functional RVEDV. The reproducibility of the measurements in the axial and short-axis views was determined within and between observers. The median value derived from the short-axis and axial views was 136 ml/m(2) (range 59 to 347) and 136 ml/m(2) (range 63 to 342) for the functional RVEDV, 153 ml/m(2) (range 64 to 441) and 154 ml/m(2) (range 67 to 436) for the total RVEDV, 49% (range 32% to 46%) and 50% (range 40% to 64%) for the functional RV ejection fraction, respectively. The axial measurements demonstrated lower intraobserver and interobserver variability than the short-axis approach for all values, with the exception of the intraobserver functional RVEDV and interobserver total RVEDV for which the limits of agreement and variance were not significantly different between the 2 views. In conclusion, measurements of right heart size and systolic function in patients with Ebstein anomaly can be reliably achieved using CMR imaging. Axial imaging appeared to provide more reproducible data than that obtained from the short-axis views.
Collapse
|
Comparative Study |
14 |
52 |
7
|
Chan RH, Maron BJ, Olivotto I, Assenza GE, Haas TS, Lesser JR, Gruner C, Crean AM, Rakowski H, Rowin E, Udelson J, Lombardi M, Tomberli B, Spirito P, Formisano F, Marra MP, Biagini E, Autore C, Manning WJ, Appelbaum E, Roberts WC, Basso C, Maron MS. Significance of Late Gadolinium Enhancement at Right Ventricular Attachment to Ventricular Septum in Patients With Hypertrophic Cardiomyopathy. Am J Cardiol 2015; 116:436-41. [PMID: 26026863 DOI: 10.1016/j.amjcard.2015.04.060] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2015] [Revised: 04/30/2015] [Accepted: 04/30/2015] [Indexed: 12/24/2022]
Abstract
Cardiovascular magnetic resonance (CMR) with extensive late gadolinium enhancement (LGE) is a novel marker for increased risk for sudden death (SD) in patients with hypertrophic cardiomyopathy (HC). Small focal areas of LGE confined to the region of right ventricular (RV) insertion to ventricular septum (VS) have emerged as a frequent and highly visible CMR imaging pattern of uncertain significance. The aim of this study was to evaluate the prognostic significance of LGE confined to the RV insertion area in patients with HC. CMR was performed in 1,293 consecutive patients with HC from 7 HC centers, followed for 3.4 ± 1.7 years. Of 1,293 patients (47 ± 14 years), 134 (10%) had LGE present only in the anterior and/or inferior areas of the RV insertion to VS, occupying 3.7 ± 2.9% of left ventricular myocardium. Neither the presence nor extent of LGE in these isolated areas was a predictor of adverse HC-related risk, including SD (adjusted hazard ratio 0.82, 95% confidence interval 0.45 to 1.50, p = 0.53; adjusted hazard ratio 1.16/10% increase in LGE, 95% confidence interval 0.29 to 4.65, p = 0.83, respectively). Histopathology in 20 HC hearts show the insertion areas of RV attachment to be composed of a greatly expanded extracellular space characterized predominantly by interstitial-type fibrosis and interspersed disorganized myocyte patterns and architecture. In conclusion, LGE confined to the insertion areas of RV to VS was associated with low risk of adverse events (including SD). Gadolinium pooling in this region of the left ventricle does not reflect myocyte death and repair with replacement fibrosis or scarring.
Collapse
|
Multicenter Study |
10 |
46 |
8
|
Thom H, West NEJ, Hughes V, Dyer M, Buxton M, Sharples LD, Jackson CH, Crean AM. Cost-effectiveness of initial stress cardiovascular MR, stress SPECT or stress echocardiography as a gate-keeper test, compared with upfront invasive coronary angiography in the investigation and management of patients with stable chest pain: mid-term outcomes from the CECaT randomised controlled trial. BMJ Open 2014; 4:e003419. [PMID: 24508847 PMCID: PMC3918982 DOI: 10.1136/bmjopen-2013-003419] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/30/2023] Open
Abstract
OBJECTIVES To compare outcomes and cost-effectiveness of various initial imaging strategies in the management of stable chest pain in a long-term prospective randomised trial. SETTING Regional cardiothoracic referral centre in the east of England. PARTICIPANTS 898 patients (69% man) entered the study with 869 alive at 2 years of follow-up. Patients were included if they presented for assessment of stable chest pain with a positive exercise test and no prior history of ischaemic heart disease. Exclusion criteria were recent infarction, unstable symptoms or any contraindication to stress MRI. PRIMARY OUTCOME MEASURES The primary outcomes of this follow-up study were survival up to a minimum of 2 years post-treatment, quality-adjusted survival and cost-utility of each strategy. RESULTS 898 patients were randomised. Compared with angiography, mortality was marginally higher in the groups randomised to cardiac MR (HR 2.6, 95% CI 1.1 to 6.2), but similar in the single photon emission CT-methoxyisobutylisonitrile (SPECT-MIBI; HR 1.0, 95% CI 0.4 to 2.9) and ECHO groups (HR 1.6, 95% CI 0.6 to 4.0). Although SPECT-MIBI was marginally superior to other non-invasive tests there were no other significant differences between the groups in mortality, quality-adjusted survival or costs. CONCLUSIONS Non-invasive cardiac imaging can be used safely as the initial diagnostic test to diagnose coronary artery disease without adverse effects on patient outcomes or increased costs, relative to angiography. These results should be interpreted in the context of recent advances in imaging technology. TRIAL REGISTRATION ISRCTN 47108462, UKCRN 3696.
Collapse
|
Comparative Study |
11 |
46 |
9
|
Ng MY, Ferreira VM, Leung ST, Yin Lee JC, Ho-Tung Fong A, To Liu RW, Man Chan JW, Wu AKL, Lung KC, Crean AM, Fan-Ngai Hung I, Siu CW. Patients Recovered From COVID-19 Show Ongoing Subclinical Myocarditis as Revealed by Cardiac Magnetic Resonance Imaging. JACC Cardiovasc Imaging 2020; 13:2476-2478. [PMID: 33153536 PMCID: PMC7455163 DOI: 10.1016/j.jcmg.2020.08.012] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 08/19/2020] [Accepted: 08/21/2020] [Indexed: 02/08/2023]
|
Letter |
5 |
44 |
10
|
Hanneman K, Sivagnanam M, Nguyen ET, Wald R, Greiser A, Crean AM, Ley S, Wintersperger BJ. Magnetic resonance assessment of pulmonary (QP) to systemic (QS) flows using 4D phase-contrast imaging: pilot study comparison with standard through-plane 2D phase-contrast imaging. Acad Radiol 2014; 21:1002-8. [PMID: 25018072 DOI: 10.1016/j.acra.2014.04.012] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2014] [Revised: 04/16/2014] [Accepted: 04/16/2014] [Indexed: 01/25/2023]
Abstract
RATIONALE AND OBJECTIVES To investigate four-dimensional (4D) phase-contrast (PC) magnetic resonance (MR) in the evaluation of intracardiac shunts by simultaneous assessment of pulmonary (QP) and systemic (QS) flows in a pilot study and to compare results to through-plane two-dimensional (2D) PC MR. MATERIALS AND METHODS Institutional review board approval and written informed consent were obtained. Nineteen patients with suspected intracardiac shunts underwent cardiac MR at 1.5T. Assessments of QP and QS were performed using free-breathing retrospectively gated 2D PC gradient recalled echo (GRE; 1.6 × 1.6 × 5 mm(3)) imaging with one-dimensional through-plane velocity encoding gradient (venc = 150 cm/s) in consecutive measurements for the main pulmonary artery (MPA) and ascending aorta (AA), respectively. A prospectively triggered 4D PC GRE technique (2.4 × 1.8 × 3 mm(3)) with three orthogonal venc directions was also used with volume coverage of both MPA and AA. RESULTS QP and QS assessed by 4D PC correlated with 2D PC acquisitions (r = 0.92 and r = 0.67 respectively; P < .0001 for both) but demonstrated significant underestimation of individual flow volumes (-21.9 ± 12.2 mL; P < .0001 and -10.7 ± 13.1 mL; P = .0023, respectively). Calculated QP:QS ratios demonstrated high correlation (r = 0.78; P < .0001) and no significant differences between 4D PC and 2D PC acquisitions (-0.09 ± 0.24, P = .14). Image acquisition times for 2D PC assessment of QP and QS were 2.98 ± 0.52 and 2.84 ± 0.50 minutes, respectively (P = .038), whereas time to acquire 4D PC images was significantly longer, 18.75 ± 4.58 minutes (P < .001). CONCLUSIONS Four-dimensional PC MR imaging allows for accurate assessment of QP:QS ratios in the evaluation of intracardiac shunts while absolute flow volumes demonstrate offsets. Further refinement of the technique with improvement in acquisition times may be required before widespread clinical implementation.
Collapse
|
Comparative Study |
11 |
43 |
11
|
Tobler D, Motwani M, Wald RM, Roche SL, Verocai F, Iwanochko RM, Greenwood JP, Oechslin EN, Crean AM. Evaluation of a comprehensive cardiovascular magnetic resonance protocol in young adults late after the arterial switch operation for d-transposition of the great arteries. J Cardiovasc Magn Reson 2014; 16:98. [PMID: 25497205 PMCID: PMC4263214 DOI: 10.1186/s12968-014-0098-5] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2014] [Accepted: 11/14/2014] [Indexed: 01/29/2023] Open
Abstract
BACKGROUND In adults with prior arterial switch operation (ASO) for d-transposition of the great arteries, the need for routine coronary artery assessment and evaluation for silent myocardial ischemia is not well defined. In this observational study we aimed to determine the value of a comprehensive cardiovascular magnetic resonance (CMR) protocol for the detection of coronary problems in adults with prior ASO for d-transposition of the great arteries. METHODS Adult ASO patients (≥18 years of age) were recruited consecutively. Patients underwent a comprehensive stress perfusion CMR protocol that included measurement of biventricular systolic function, myocardial scar burden, coronary ostial assessment and myocardial perfusion during vasodilator stress by perfusion CMR. Single photon emission computed tomography (SPECT) was performed on the same day as a confirmatory second imaging modality. Stress studies were visually assessed for perfusion defects (qualitative analysis). Additionally, myocardial blood flow was quantitatively analysed from mid-ventricular perfusion CMR images. In unclear cases, CT coronary angiography or conventional angiography was done. RESULTS Twenty-seven adult ASO patients (mean age 23 years, 85% male, 67% with a usual coronary pattern; none with a prior coronary artery complication) were included in the study. CMR stress perfusion was normal in all 27 patients with no evidence of inducible perfusion defects. In 24 cases the coronary ostia could conclusively be demonstrated to be normal. There was disagreement between CMR and SPECT for visually-assessed perfusion defects in 54% of patients with most disagreement due to false positive SPECT. CONCLUSIONS Adult ASO survivors in this study had no CMR evidence of myocardial ischemia, scar or coronary ostial abnormality. Compared to SPECT, CMR provides additional valuable information about the coronary artery anatomy. The data shows that the asymptomatic and clinically stable adult ASO patient has a low pre-test probability for inducible ischemia. In this situation it is likely that routine evaluation with stress CMR is unnecessary.
Collapse
|
Evaluation Study |
11 |
43 |
12
|
Tobler D, Crean AM, Redington AN, Van Arsdell GS, Caldarone CA, Nanthakumar K, Stambach D, Dos L, Wintersperger BJ, Oechslin EN, Silversides CK, Wald RM. The left heart after pulmonary valve replacement in adults late after tetralogy of Fallot repair. Int J Cardiol 2012; 160:165-70. [DOI: 10.1016/j.ijcard.2011.04.007] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/23/2010] [Revised: 03/23/2011] [Accepted: 04/14/2011] [Indexed: 10/18/2022]
|
|
13 |
36 |
13
|
Spears DA, Suszko AM, Dalvi R, Crean AM, Ivanov J, Nanthakumar K, Downar E, Chauhan VS. Relationship of bipolar and unipolar electrogram voltage to scar transmurality and composition derived by magnetic resonance imaging in patients with nonischemic cardiomyopathy undergoing VT ablation. Heart Rhythm 2012; 9:1837-46. [PMID: 22846338 DOI: 10.1016/j.hrthm.2012.07.022] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2011] [Indexed: 12/31/2022]
Abstract
BACKGROUND Bipolar voltage mapping has a role in defining endocardial-based scar in postinfarct patients undergoing ventricular tachycardia catheter ablation. The utility of bipolar and unipolar voltages in characterizing scar has not been evaluated in patients with nonischemic cardiomyopathy. OBJECTIVE To relate left ventricular (LV) endocardial bipolar and unipolar voltages in these patients to scar transmurality (endocardial vs nonendocardial) and composition (homogeneous core vs heterogeneous gray). METHODS Ten consecutive cardiomyopathy patients undergoing endocardial LV tachycardia ablation were included (age 48 ± 14 years; left ventricular ejection fraction 43% ± 15%). Preablation late gadolinium-enhanced magnetic resonance imaging was used to quantify core and gray scar by using signal-intensity thresholding. Electroanatomic LV endocardial mapping provided bipolar and unipolar voltages. Electroanatomic maps and late gadolinium-enhanced magnetic resonance imaging were rigidly registered in order to relate voltage to scar (registration error 3.6 ± 2.9 mm). RESULTS Bipolar voltage was lower in endocardial core than in no scar (P <.001). Unipolar voltage was lower in endocardial core and nonendocardial core than in no scar (P <.001). Endocardial and nonendocardial gray scar had an effect similar to that of core in reducing bipolar and unipolar voltages (P <.001). The mass of healthy myocardium and endocardial core scar independently predicted bipolar and unipolar voltages using general estimating equation modeling. With receiver operating characteristic curve analysis, bipolar voltage >1.9 mV and unipolar voltage <6.7 mV had a high negative predictive value (91%) for detecting nonendocardial scar from either endocardial scar or no scar. CONCLUSIONS In patients with nonischemic cardiomyopathy, LV endocardial bipolar voltage is dependent on endocardial core and gray scar, while the unipolar voltage is influenced by core and gray scar across the LV wall as defined by late gadolinium-enhanced magnetic resonance imaging.
Collapse
|
Journal Article |
13 |
33 |
14
|
Noiseux N, Mansour S, Weisel R, Stevens LM, Der Sarkissian S, Tsang K, Crean AM, Larose E, Li SH, Wintersperger B, Vu MQ, Prieto I, Li RK, Roy DC, Yau TM. The IMPACT-CABG trial: A multicenter, randomized clinical trial of CD133+ stem cell therapy during coronary artery bypass grafting for ischemic cardiomyopathy. J Thorac Cardiovasc Surg 2016; 152:1582-1588.e2. [DOI: 10.1016/j.jtcvs.2016.07.067] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/03/2016] [Revised: 06/15/2016] [Accepted: 07/01/2016] [Indexed: 11/26/2022]
|
|
9 |
32 |
15
|
Tobler D, Yalonetsky S, Crean AM, Granton JT, Burchill L, Silversides CK, Wald RM. Right heart characteristics and exercise parameters in adults with Ebstein anomaly: new perspectives from cardiac magnetic resonance imaging studies. Int J Cardiol 2011; 165:146-50. [PMID: 21872945 DOI: 10.1016/j.ijcard.2011.08.004] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/2011] [Revised: 07/14/2011] [Accepted: 08/03/2011] [Indexed: 11/25/2022]
Abstract
BACKGROUND The utility of cardiac magnetic resonance imaging (CMR) for assessment of adults with Ebstein anomaly is not well-defined. We sought to evaluate CMR characteristics in this population and to relate these to exercise parameters. METHODS We analyzed CMR studies in adults with unrepaired Ebstein anomaly for measures of severity of Ebstein disease, including atrialized, functional and total right ventricular (RV) volumes, ejection fraction (EF) and severity index (area of atrialized RV+right atrium/functional RV+left ventricle+left atrium). We related these CMR values to cardiopulmonary exercise test measurements. RESULTS Twenty-seven adults (mean age 41 ± 14 years, 70% female) were included. Functional RV end-diastolic volume (EDV) was 150 ± 68 mL/m(2) and atrialized RVEDV was 25 ± 24 mL/m(2). In 17 patients (63%), the functional RVEDV was enlarged (>114 mL/m(2)). Percent predicted peak VO2 for the population was 65 ± 20%. On univariable analysis, peak VO2 was inversely related to atrialized RVEDV (p = 0.011), total RVEDV (p = 0.041), functional RVEDV/left ventricular EDV ratio (p = 0.015) and magnitude of tricuspid valve displacement (p = 0.031). In the multivariate model, the only CMR factor to relate to peak VO2 was atrialized RVEDV (p = 0.011, β = -0.48). No significant correlations were found between CMR measures and heart rate response or ventilatory response to exercise. CONCLUSION In adults with unrepaired Ebstein anomaly, atrialized RV volume was independently related to aerobic capacity. The volume of the atrialized RV is a novel CMR measure which may express severity of disease. Further research is needed to evaluate the prognostic relevance of this exploratory work.
Collapse
|
Journal Article |
14 |
30 |
16
|
Weissler-Snir A, Hindieh W, Gruner C, Fourey D, Appelbaum E, Rowin E, Care M, Lesser JR, Haas TS, Udelson JE, Manning WJ, Olivotto I, Tomberli B, Maron BJ, Maron MS, Crean AM, Rakowski H, Chan RH. Lack of Phenotypic Differences by Cardiovascular Magnetic Resonance Imaging in MYH7 (β-Myosin Heavy Chain)- Versus MYBPC3 (Myosin-Binding Protein C)-Related Hypertrophic Cardiomyopathy. Circ Cardiovasc Imaging 2017; 10:CIRCIMAGING.116.005311. [PMID: 28193612 DOI: 10.1161/circimaging.116.005311] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/22/2016] [Accepted: 12/19/2016] [Indexed: 01/11/2023]
Abstract
BACKGROUND The 2 most commonly affected genes in hypertrophic cardiomyopathy (HCM) are MYH7 (β-myosin heavy chain) and MYBPC3 (β-myosin-binding protein C). Phenotypic differences between patients with mutations in these 2 genes have been inconsistent. Scarce data exist on the genotype-phenotype association as assessed by tomographic imaging using cardiac magnetic resonance imaging. METHODS AND RESULTS Cardiac magnetic resonance imaging was performed on 358 consecutive genotyped hypertrophic cardiomyopathy probands at 5 tertiary hypertrophic cardiomyopathy centers. Genetic testing revealed a pathogenic mutation in 159 patients (44.4%). The most common genes identified were MYH7 (n=53) and MYBPC3 (n=75); 33.1% and 47% of genopositive patients, respectively. Phenotypic characteristics by cardiac magnetic resonance imaging of these 2 groups were similar, including left ventricular volumes, mass, maximal wall thickness, morphology, left atrial volume, and mitral valve leaflet lengths (all P=non-significant). The presence of late gadolinium enhancement (65% versus 64%; P=0.99) and the proportion of total left ventricular mass (%late gadolinium enhancement; 10.4±13.2% versus 8.5±8.5%; P=0.44) were also similar. CONCLUSIONS This multicenter multinational study shows lack of phenotypic differences between MYH7- and MYBPC3-associated hypertrophic cardiomyopathy when assessed by cardiac magnetic resonance imaging. Postmutational mechanisms appear more relevant to thick-filament disease expression and outcome than the disease-causing variant per se.
Collapse
MESH Headings
- Adult
- Canada
- Cardiac Myosins/genetics
- Cardiomyopathy, Hypertrophic, Familial/diagnostic imaging
- Cardiomyopathy, Hypertrophic, Familial/genetics
- Cardiomyopathy, Hypertrophic, Familial/physiopathology
- Carrier Proteins/genetics
- Contrast Media/administration & dosage
- Europe
- Female
- Gadolinium DTPA/administration & dosage
- Genetic Association Studies
- Genetic Predisposition to Disease
- Humans
- Image Interpretation, Computer-Assisted
- Imaging, Three-Dimensional
- Magnetic Resonance Imaging, Cine
- Male
- Middle Aged
- Mutation
- Myosin Heavy Chains/genetics
- Phenotype
- Predictive Value of Tests
- Registries
- Risk Factors
- Stroke Volume
- Tertiary Care Centers
- United States
- Ventricular Function, Left
- Ventricular Remodeling
Collapse
|
Multicenter Study |
8 |
30 |
17
|
Joshi SB, Connelly KA, Jimenez-Juan L, Hansen M, Kirpalani A, Dorian P, Mangat I, Al-Hesayen A, Crean AM, Wright GA, Yan AT, Leong-Poi H. Potential clinical impact of cardiovascular magnetic resonance assessment of ejection fraction on eligibility for cardioverter defibrillator implantation. J Cardiovasc Magn Reson 2012; 14:69. [PMID: 23043729 PMCID: PMC3482389 DOI: 10.1186/1532-429x-14-69] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2012] [Accepted: 09/27/2012] [Indexed: 01/29/2023] Open
Abstract
BACKGROUND For the primary prevention of sudden cardiac death, guidelines provide left ventricular ejection fraction (EF) criteria for implantable cardioverter defibrillator (ICD) placement without specifying the technique by which it should be measured. We sought to investigate the potential impact of performing cardiovascular magnetic resonance (CMR) for EF on ICD eligibility. METHODS The study population consisted of patients being considered for ICD implantation who were referred for EF assessment by CMR. Patients who underwent CMR within 30 days of echocardiography were included. Echocardiographic EF was determined by Simpson's biplane method and CMR EF was measured by Simpson's summation of discs method. RESULTS Fifty-two patients (age 62±15 years, 81% male) had a mean EF of 38 ± 14% by echocardiography and 35 ± 14% by CMR. CMR had greater reproducibility than echocardiography for both intra-observer (ICC, 0.98 vs 0.94) and inter-observer comparisons (ICC 0.99 vs 0.93). The limits of agreement comparing CMR and echocardiographic EF were - 16 to +10 percentage points. CMR resulted in 11 of 52 (21%) and 5 of 52 (10%) of patients being reclassified regarding ICD eligibility at the EF thresholds of 35 and 30% respectively. Among patients with an echocardiographic EF of between 25 and 40%, 9 of 22 (41%) were reclassified by CMR at either the 35 or 30% threshold. Echocardiography identified only 1 of the 6 patients with left ventricular thrombus noted incidentally on CMR. CONCLUSIONS CMR resulted in 21% of patients being reclassified regarding ICD eligibility when strict EF criteria were used. In addition, CMR detected unexpected left ventricular thrombus in almost 10% of patients. Our findings suggest that the use of CMR for EF assessment may have a substantial impact on management in patients being considered for ICD implantation.
Collapse
MESH Headings
- Aged
- Death, Sudden, Cardiac/etiology
- Death, Sudden, Cardiac/prevention & control
- Defibrillators, Implantable
- Echocardiography
- Electric Countershock/instrumentation
- Eligibility Determination
- Female
- Humans
- Magnetic Resonance Imaging
- Male
- Middle Aged
- Observer Variation
- Ontario
- Patient Selection
- Predictive Value of Tests
- Reproducibility of Results
- Stroke Volume
- Thrombosis/complications
- Thrombosis/diagnosis
- Thrombosis/physiopathology
- Thrombosis/therapy
- Ventricular Dysfunction, Left/complications
- Ventricular Dysfunction, Left/diagnosis
- Ventricular Dysfunction, Left/physiopathology
- Ventricular Dysfunction, Left/therapy
- Ventricular Function, Left
Collapse
|
Comparative Study |
13 |
29 |
18
|
Burchill LJ, Huang J, Tretter JT, Khan AM, Crean AM, Veldtman GR, Kaul S, Broberg CS. Noninvasive Imaging in Adult Congenital Heart Disease. Circ Res 2017; 120:995-1014. [DOI: 10.1161/circresaha.116.308983] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/01/2016] [Revised: 02/17/2017] [Accepted: 02/17/2017] [Indexed: 11/16/2022]
Abstract
Multimodality cardiovascular imaging plays a central role in caring for patients with congenital heart disease (CHD). CHD clinicians and scientists are interested not only in cardiac morphology but also in the maladaptive ventricular responses and extracellular changes predisposing to adverse outcomes in this population. Expertise in the applications, strengths, and pitfalls of these cardiovascular imaging techniques as they relate to CHD is essential. The purpose of this article is to provide an overview of cardiovascular imaging in CHD. We focus on the role of 3 widely used noninvasive imaging techniques in CHD—echocardiography, cardiac magnetic resonance imaging, and cardiac computed tomography. Consideration is given to the common goals of cardiac imaging in CHD, including assessment of structural and residual heart disease before and after surgery, quantification of ventricular volume and function, stress imaging, shunt quantification, and tissue characterization. Extracardiac imaging is highlighted as an increasingly important aspect of CHD care.
Collapse
|
|
8 |
28 |
19
|
Hanneman K, Crean AM, Wintersperger BJ, Thavendiranathan P, Nguyen ET, Kayedpour C, Wald RM. The relationship between cardiovascular magnetic resonance imaging measurement of extracellular volume fraction and clinical outcomes in adults with repaired tetralogy of Fallot. Eur Heart J Cardiovasc Imaging 2017; 19:777-784. [DOI: 10.1093/ehjci/jex248] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/06/2017] [Accepted: 09/28/2017] [Indexed: 12/14/2022] Open
|
|
8 |
23 |
20
|
James SH, Wald R, Wintersperger BJ, Jimenez-Juan L, Deva D, Crean AM, Nguyen E, Paul NS, Ley S. Accuracy of right and left ventricular functional assessment by short-axis vs axial cine steady-state free-precession magnetic resonance imaging: intrapatient correlation with main pulmonary artery and ascending aorta phase-contrast flow measurements. Can Assoc Radiol J 2012; 64:213-9. [PMID: 22579337 DOI: 10.1016/j.carj.2011.12.016] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2011] [Revised: 11/11/2011] [Accepted: 12/19/2011] [Indexed: 11/30/2022] Open
Abstract
OBJECTIVE The left ventricle (LV) is routinely assessed with cardiac magnetic resonance imaging (MRI) by using short-axis orientation; it remains unclear whether the right ventricle (RV) can also be adequately assessed in this orientation or whether dedicated axial orientation is required. We used phase-contrast (PC) flow measurements in the main pulmonary artery (MPA) and the ascending aorta (Aorta) as nonvolumetric standard of reference and compared RV and LV volumes in short-axis and axial orientations. METHODS A retrospective analysis identified 30 patients with cardiac MRI data sets. Patients underwent MRI (1.5 T or 3 T), with retrospectively gated cine steady-state free-precession in axial and short-axis orientations. PC flow analyses of MPA and Aorta were used as the reference measure of RV and LV output. RESULTS There was a high linear correlation between MPA-PC flow and RV-stroke volume (SV) short axis (r = 0.9) and RV-SV axial (r = 0.9). Bland-Altman analysis revealed a mean offset of 1.4 mL for RV axial and -2.3 mL for RV-short-axis vs MPA-PC flow. There was a high linear correlation between Aorta-PC flow and LV-SV short-axis (r = 0.9) and LV-SV axial (r = 0.9). Bland-Altman analysis revealed a mean offset of 4.8 m for LV short axis and 7.0 mL for LV axial vs Aorta-PC flow. There was no significant difference (P = .6) between short-axis-LV SV and short-axis-RV SV. CONCLUSION No significant impact of the slice acquisition orientation for determination of RV and LV stroke volumes was found. Therefore, cardiac magnetic resonance workflow does not need to be extended by an axial data set for patients without complex cardiac disease for assessment of biventricular function and volumes.
Collapse
|
Journal Article |
13 |
22 |
21
|
Chen YA, Nguyen ET, Dennie C, Wald RM, Crean AM, Yoo SJ, Jimenez-Juan L. Computed tomography and magnetic resonance imaging of the coronary sinus: anatomic variants and congenital anomalies. Insights Imaging 2014; 5:547-57. [PMID: 25048808 PMCID: PMC4195839 DOI: 10.1007/s13244-014-0330-8] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2013] [Revised: 03/05/2014] [Accepted: 03/10/2014] [Indexed: 01/25/2023] Open
Abstract
The coronary sinus (CS) is an important vascular structure that allows for access into the coronary veins in multiple interventional cardiology procedures, including catheter ablation of arrhythmias, pacemaker implantation and retrograde cardioplegia. The success of these procedures is facilitated by the knowledge of the CS anatomy, in particular the recognition of its variants and anomalies. This pictorial essay reviews the spectrum of CS anomalies, with particular attention to the distinction between clinically benign variants and life-threatening defects. Emphasis will be placed on the important role of cardiac CT and cardiovascular magnetic resonance in providing detailed anatomic and functional information of the CS and its relationship to surrounding cardiac structures. Teaching Points • Cardiac CT and cardiovascular magnetic resonance offer 3D high-resolution mapping of the coronary sinus in pre-surgical planning.• Congenital coronary sinus enlargement occurs in the presence or absence of a left-to-right shunt.• Lack of recognition of coronary sinus anomalies can lead to adverse outcomes in cardiac procedures.• In coronary sinus ostial atresia, coronary venous drainage to the atria occurs via Thebesian or septal veins.• Coronary sinus diverticulum is a congenital outpouching of the coronary sinus and may predispose to cardiac arrhythmias.
Collapse
|
review-article |
11 |
22 |
22
|
Crean AM, Abdel-Rahman SEDT, Greenwood JP. A sweet tooth as the root cause of cardiac arrest. Can J Cardiol 2009; 25:e357-8. [PMID: 19812810 DOI: 10.1016/s0828-282x(09)70723-8] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
A 71-year-old woman was admitted with hypotension and bradycardia. An electrocardiogram showed flattened T waves and increased U wave prominence, resulting in a long QT(U) syndrome. Her initial serum potassium level was 1.6 mmol/L (all other electrolytes, including magnesium, were normal). She suffered recurrent ventricular tachycardia and ventricular fibrillation arrest requiring direct current cardioversion and high-dose intravenous potassium chloride replacement. Systematic enquiry revealed that she had been constipated for a number of months and had resorted to consuming large quantities of liquorice on a daily basis for its laxative effects. Endocrinology review identified no primary abnormality of the renin- angiotensin- aldosterone axis, and the patient was diagnosed with hypokalemia secondary to liquorice overindulgence. Liquorice has a mineralocorticoid effect. If chronically consumed in large quantities, this effect may lead to severe depletion of whole-body potassium stores. The present case highlights a rare but important cause of hypokalemic cardiac arrest of which all acute care physicians should be aware.
Collapse
|
Journal Article |
16 |
22 |
23
|
Coulden RA, Sonnex EP, Abele JT, Crean AM. Utility of FDG PET and Cardiac MRI in Diagnosis and Monitoring of Immunosuppressive Treatment in Cardiac Sarcoidosis. Radiol Cardiothorac Imaging 2020; 2:e190140. [PMID: 33778595 PMCID: PMC7977729 DOI: 10.1148/ryct.2020190140] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Revised: 04/02/2020] [Accepted: 04/09/2020] [Indexed: 11/11/2022]
Abstract
PURPOSE To compare the contributions of cardiac MRI and PET in the diagnosis and management of cardiac sarcoidosis (CS), with particular reference to quantitative measures. MATERIALS AND METHODS This is a retrospective, observational study of 31 patients (mean age, 45.7 years) with proven extracardiac sarcoidosis and possible CS who were investigated with fluorine 18 fluorodeoxyglucose (FDG) PET/CT and cardiac MRI. Patients were treated at physicians' discretion with repeat combined imaging after an interval of 102-770 days (median, 228 days). RESULTS Significant myocardial FDG uptake was shown on visit 1 (myocardial maximum standardized uptake value [SUVmax] > 3.6) in 17 of 22 patients who were subsequently treated. Myocardial SUVmax decreased at follow-up (6.5 to 4.0; P < .01) and was matched by significant decreases in FDG-avid lung and mediastinal node disease. A volumetric measure of myocardium above a threshold SUV (cardiac metabolic volume) decreased from a mean of 42.5 to a mean of 4.1 (P < .001). This was associated with significant improvement in the left ventricular ejection fraction (LVEF) (45.8 increasing to 50.9; P < .031). There was no change in volume of late gadolinium enhancement at treatment. Patients who were untreated showed no change in any FDG PET or cardiac MRI parameter. CONCLUSION Myocardial FDG uptake in patients suspected of having CS is presumed to represent active inflammation. When treated with corticosteroids, this resolved or regressed at follow-up, with an improvement in LVEF and FDG-avid thoracic disease. Patients who were untreated showed no change in any parameter. Quantification of FDG-avid myocardium using cardiac metabolic volume is proposed as a useful objective measure for assessing response to therapy.© RSNA, 2020See also commentary by Gutberlet in this issue.
Collapse
|
research-article |
5 |
20 |
24
|
Shariat M, Thavendiranathan P, Nguyen E, Wintersperger B, Paul N, Rakowski H, Crean AM. Utility of coronary CT angiography in outpatients with hypertrophic cardiomyopathy presenting with angina symptoms. J Cardiovasc Comput Tomogr 2014; 8:429-37. [DOI: 10.1016/j.jcct.2014.09.007] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2014] [Revised: 08/15/2014] [Accepted: 09/16/2014] [Indexed: 12/25/2022]
|
|
11 |
17 |
25
|
Robison S, Karur GR, Wald RM, Thavendiranathan P, Crean AM, Hanneman K. Noninvasive hematocrit assessment for cardiovascular magnetic resonance extracellular volume quantification using a point-of-care device and synthetic derivation. J Cardiovasc Magn Reson 2018; 20:19. [PMID: 29544519 PMCID: PMC5856214 DOI: 10.1186/s12968-018-0443-1] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2017] [Accepted: 03/05/2018] [Indexed: 01/25/2023] Open
Abstract
BACKGROUND Calculation of cardiovascular magnetic resonance (CMR) extracellular volume (ECV) requires input of hematocrit, which may not be readily available. The purpose of this study was to evaluate the diagnostic accuracy of ECV calculated using various noninvasive measures of hematocrit compared to ECV calculated with input of laboratory hematocrit as the reference standard. METHODS One hundred twenty three subjects (47.7 ± 14.1 years; 42% male) were prospectively recruited for CMR T1 mapping between August 2016 and April 2017. Laboratory hematocrit was assessed by venipuncture. Noninvasive hematocrit was assessed with a point-of-care (POC) device (Pronto-7® Pulse CO-Oximeter®, Masimo Personal Health, Irvine, California, USA) and by synthetic derivation based on the relationship with blood pool T1 values. Left ventricular ECV was calculated with input of laboratory hematocrit (Lab-ECV), POC hematocrit (POC-ECV), and synthetic hematocrit (synthetic-ECV), respectively. Statistical analysis included Wilcoxon signed-rank test, Bland-Altman analysis, receiver-operating curve analysis and intra-class correlation (ICC). RESULTS There was no significant difference between Lab-ECV and POC-ECV (27.1 ± 4.7% vs. 27.3 ± 4.8%, p = 0.106), with minimal bias and modest precision (bias - 0.18%, 95%CI [- 2.85, 2.49]). There was no significant difference between Lab-ECV and synthetic-ECV (26.7 ± 4.4% vs. 26.5 ± 4.3%, p = 0.084) in subjects imaged at 1.5 T, although bias was slightly higher and limits of agreement were wider (bias 0.23%, 95%CI [- 2.82, 3.27]). For discrimination of abnormal Lab-ECV ≥30%, POC-ECV had good diagnostic performance (sensitivity 85%, specificity 96%, accuracy 94%, and AUC 0.902) and synthetic-ECV had moderate diagnostic performance (sensitivity 71%, specificity 98%, accuracy 93%, and AUC 0.849). POC-ECV had excellent test-retest (ICC 0.994, 95%CI[0.987, 0.997]) and inter-observer agreement (ICC 0.974, 95%CI[0.929, 0.991]). CONCLUSIONS Myocardial ECV can be accurately and reproducibly calculated with input of hematocrit measured using a noninvasive POC device, potentially overcoming an important barrier to implementation of ECV. Further evaluation of synthetic ECV is required prior to clinical implementation.
Collapse
|
Comparative Study |
7 |
15 |