1
|
Airway inflammation and dysbiosis in antibody deficiency despite the presence of IgG. J Allergy Clin Immunol 2021; 149:2105-2115.e10. [PMID: 34968528 DOI: 10.1016/j.jaci.2021.12.778] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Revised: 12/14/2021] [Accepted: 12/17/2021] [Indexed: 11/15/2022]
Abstract
BACKGROUND Patients with antibody deficiency suffer chronic respiratory symptoms, recurrent exacerbations and progressive airways disease despite systemic replacement of Immunoglobulin G. Little is known about the respiratory tract biology of these patients. OBJECTIVE To measure immunoglobulin levels, inflammatory cytokines and mediators of tissue damage in serum and sputum from patients with antibody deficiency and healthy controls; to analyse the respiratory microbiome in the same cohorts. METHODS We obtained paired sputum and serum samples from 31 immunocompetent subjects and 67 antibody deficient patients, the latter divided on computed tomography scan appearance into 'abnormal airways' (bronchiectasis or airway thickening) or 'normal airways'. We measured inflammatory cytokines, immunoglobulin levels, neutrophil elastase, matrix-metalloproteinase-9, urea, albumin and total protein levels using standard assays. We employed V3-V4 region 16S sequencing for microbiome analysis. RESULTS Immunodeficient patients had markedly reduced Immunoglobulin A in sputum but higher concentrations of Immunoglobulin G compared to healthy controls. Inflammatory cytokines and tissue damage markers were higher in immunodeficient patients, who also exhibited dysbiosis with over-representation of pathogenic taxa and significantly reduced alpha diversity compared to immunocompetent individuals. These differences were seen regardless of airway morphology. Sputum matrix metalloproteinase-9 and elastase correlated inversely with alpha diversity in the antibody deficient group, as did sputum Immunoglobulin G, which correlated positively with several inflammatory markers, even after correction for albumin levels. CONCLUSION Patients with antibody deficiency, even with normal lung imaging, exhibit inflammation and dysbiosis in their airways despite higher levels of Immunoglobulin G compared to healthy controls.
Collapse
|
2
|
Effects of Continuous Plasma-Derived Subcutaneous C1-Esterase Inhibitor on Coagulation and Fibrinolytic Parameters. Thromb Haemost 2020; 121:690-693. [PMID: 33202446 DOI: 10.1055/s-0040-1721147] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
3
|
Pharmacokinetics and pharmacodynamics of a recombinant fusion protein linking activated coagulation factor VII with human albumin (rVIIa-FP) in patients with congenital FVII deficiency. ACTA ACUST UNITED AC 2020; 25:17-25. [PMID: 31852380 DOI: 10.1080/16078454.2019.1700329] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Objectives: Recombinant fusion protein linking activated factor VIIa to human albumin (rVIIa-FP) is a therapeutic option designed to prevent and treat bleeding events in patients with congenital FVII deficiency with reduced infusion frequency compared to current FVII treatments. This study characterized the pharmacokinetics (PK) and pharmacodynamics (PD) of rVIIa-FP.Methods: A phase I multicenter, randomized, open-label, parallel-arm, single-dose study (NCT02470871) was conducted in nine patients with severe congenital FVII deficiency. Patients received their routine FVII product (30 IU/kg plasma-derived FVII [pdFVII] or 25 μg/kg recombinant activated FVII (rFVIIa) [eptacog alfa]), and were then randomly assigned to receive 100 or 300 μg/kg of rVIIa-FP. Blood samples for PK and PD assessments were drawn up to 48 hr after administration. FVIIa activity was determined using a one-stage clotting assay. PD parameters were derived from thrombin generation testing, using the Nijmegen hemostasis assay.Results: rVIIa-FP showed improved PK compared to rFVIIa, with 2- to 3-fold longer t1/2 and 4- to 8-fold lower clearance. Analysis of PD data showed a sustained suppression of lag time below 4.5 min (upper limit of healthy people) for rVIIa-FP compared to rFVIIa. AUEC and ECmax were similar across the two dose groups of rVIIa-FP and rFVIIa.Discussion: rVIIa-FP was well tolerated in patients with congenital FVII deficiency, showed a longer half-life and lower clearance compared to rFVIIa, and lag time remaining within healthy ranges for ≥8 hr.Conclusion: These results warrant further investigation into the efficacy of rVIIa-FP to control and prevent bleeding in patients with FVII deficiency.
Collapse
|
4
|
Population pharmacokinetics of subcutaneous C1-inhibitor for prevention of attacks in patients with hereditary angioedema. Clin Exp Allergy 2018; 48:1325-1332. [PMID: 29998524 DOI: 10.1111/cea.13220] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Revised: 06/06/2018] [Accepted: 06/17/2018] [Indexed: 12/17/2022]
Abstract
BACKGROUND Long-term prophylaxis with subcutaneous (SC) administration of a highly concentrated plasma-derived C1-esterase inhibitor (C1-INH) formulation was recently approved by the Food and Drug Administration for hereditary angioedema (HAE) attack prevention. OBJECTIVE To characterize the population pharmacokinetics of C1-INH (SC) (HAEGARDA® ; CSL Behring) in healthy volunteers and HAE patients, and assess the variability and influence of covariates on pharmacokinetics. METHODS C1-INH functional activity data obtained after administration of various C1-INH (intravenous; IV) and C1-INH (SC) doses from 1 study in healthy volunteers (n = 16) and 2 studies in subjects with HAE (n = 108) were pooled to develop a population pharmacokinetic model (NONMEM v7.2). Pharmacokinetic parameters derived from steady-state simulations based on the final model were also evaluated. RESULTS C1-INH functional activity following C1-INH (SC) administration was described by a linear one-compartment model with first-order absorption and elimination, with inter-individual variability in all parameters tested. The mean population bioavailability of C1-INH (SC), and pharmacokinetic parameters for clearance (CL), volume of distribution, and absorption rate were estimated to be ~43%, 1.03 mL/hour/kg, 0.05 L/kg and 0.0146 hour-1 , respectively. The effect of bodyweight on CL of C1-INH functional activity was included in the final model, estimated to be 0.74. Steady-state simulations of C1-INH functional activity vs time profiles in 1000 virtual HAE patients revealed higher minimum functional activity (Ctrough ) levels after twice-weekly dosing with 40 IU/kg (~40%) and 60 IU/kg (~48%) compared with 1000 IU IV (~30%). Based on the population pharmacokinetic model, the median time to peak concentration was ~59 hours and the median apparent plasma half-life was ~69 hours. CONCLUSIONS AND CLINICAL RELEVANCE Twice-weekly bodyweight-adjusted dosing of C1-INH (SC) exhibits linear pharmacokinetics and dose-dependent increases in Ctrough levels at each dosing interval. In this analysis, SC dosing led to maintenance of higher Ctrough levels than IV dosing.
Collapse
|
5
|
International comparative field study evaluating the assay performance of AFSTYLA in plasma samples at clinical hemostasis laboratories. J Thromb Haemost 2018; 16:555-564. [PMID: 29274194 DOI: 10.1111/jth.13932] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2017] [Indexed: 02/07/2023]
Abstract
Essentials AFSTYLA exhibits ≈50% underestimation in activity when the one-stage (OS) assay is utilized. A field study compared the performance of AFSTYLA with Advate in factor VIII activity assays. AFSTYLA activity can be monitored with both the chromogenic substrate and the OS assay. The consistent OS underestimation allows for a conversion factor to be applied to OS results. SUMMARY Introduction AFSTYLA (antihemophilic factor [recombinant] single chain) is a novel B-domain truncated recombinant factor VIII (rFVIII). For AFSTYLA, an approximate 50% discrepancy was observed between results of the one-stage (OS) and chromogenic substrate (ChS) FVIII activity assays. An investigation was undertaken to test whether there is a linear relationship between ChS and OS assay results that would allow reliable clinical interpretation of results independent of the assay method used. Aims To provide confidence in future clinical monitoring, this field study investigated the performance of AFSTYLA and a full-length rFVIII (Advate® ) in FVIII activity assays routinely performed in clinical laboratories. Methods The comparison of AFSTYLA and Advate was performed in an international, multicenter and blinded field study of simulated post-infusion samples. The study documented the extent of variability between methods and laboratories and characterized the relationship between the ChS and OS assays. Results Results from 23 laboratories demonstrate that intra and interlaboratory variability in OS assays were similar for both products. When comparing within the OS assay format, there was a similar and reagent-correlated variability in response to different activators for both AFSTYLA and Advate. The OS underestimation was highly predictable and consistent across the complete range of FVIII plasma concentrations. Conclusion Post-infusion plasma AFSTYLA levels can be monitored in patients by the OS and ChS assays. The consistent and predictable difference between the two assay formats provides clinicians with adequate guidance on how to interpret the results of the OS assay using a single conversion factor.
Collapse
|
6
|
|
7
|
Population pharmacokinetics of recombinant coagulation factor VIII-SingleChain in patients with severe hemophilia A. J Thromb Haemost 2017; 15:1106-1114. [PMID: 28244200 DOI: 10.1111/jth.13662] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2016] [Accepted: 02/12/2017] [Indexed: 02/06/2023]
Abstract
Essentials rVIII-SingleChain is a unique recombinant factor VIII (FVIII) molecule. A population pharmacokinetic model was based on FVIII activity of severe hemophilia A patients. The model was used to simulate factor VIII activity-time profiles for various dosing scenarios. The model supports prolonged dosing of rVIII-SingleChain with intervals of up to twice per week. SUMMARY Background Single-chain recombinant coagulation factor VIII (rVIII-SingleChain) is a unique recombinant coagulation factor VIII molecule. Objectives To: (i) characterize the population pharmacokinetics (PK) of rVIII-SingleChain in patients with severe hemophilia A; (ii) identify correlates of variability in rVIII-SingleChain PK; and (iii) simulate various dosing scenarios of rVIII-SingleChain. Patients/Methods A population PK model was developed, based on FVIII activity levels of 130 patients with severe hemophilia A (n = 91 for ≥ 12-65 years; n = 39 for < 12 years) who had participated in a single-dose PK investigation with rVIII-SingleChain 50 IU kg-1 . PK sampling was performed for up to 96 h. Results A two-compartment population PK model with first-order elimination adequately described FVIII activity. Body weight and predose level of von Willebrand factor were significant covariates on clearance, and body weight was a significant covariate on the central distribution volume. Simulations using the model with various dosing scenarios estimated that > 85% and > 93% of patients were predicted to maintain FVIII activity level above 1 IU dL-1 , at all times with three-times-weekly dosing (given on days 0, 2, and 4.5) at the lowest (20 IU kg-1 ) and highest (50 IU kg-1 ) doses, respectively. For twice weekly dosing (days 0 and 3.5) of 50 IU kg-1 rVIII-SingleChain, 62-80% of patients across all ages were predicted to maintain a FVIII activity level above 1 IU dL-1 at day 7. Conclusions The population PK model adequately characterized rVIII-SingleChain PK, and the model can be utilized to simulate FVIII activity-time profiles for various dosing scenarios.
Collapse
|
8
|
Population pharmacokinetics of a new long-acting recombinant coagulation factor IX albumin fusion protein for patients with severe hemophilia B. J Thromb Haemost 2016; 14:2132-2140. [PMID: 27513989 DOI: 10.1111/jth.13444] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2016] [Indexed: 11/29/2022]
Abstract
Essentials The new recombinant factor IX (FIX) albumin fusion protein (rIX-FP) has a prolonged half-life. A population pharmacokinetic (PK) model was based on FIX activity levels of hemophilia B patients. The model was used to simulate different dosing scenarios of rIX-FP to help guide dosing. The population PK model supported prolonged dosing of rIX-FP with intervals of up to 2 weeks. Click to hear Prof.Makris's presentation on new treatments in hemophilia SUMMARY: Background The recombinant fusion protein linking recombinant coagulation factor IX with recombinant albumin (rIX-FP; Idelvion® ) exhibits a longer half-life than plasma-derived factor IX (FIX) and the commercially available recombinant FIX products. Objectives (i) Characterize the population pharmacokinetics (PK) of rIX-FP in hemophilia B patients, (ii) identify covariates that are potential determinants of rIX-FP PK variability and (iii) simulate different dosing scenarios of rIX-FP following single and steady-state dosing. Patients/Methods A population PK model was developed based on FIX activity levels of 104 patients who had received treatment with rIX-FP. Patients were aged 1-65 years with FIX activity ≤ 2 IU dL-1 . PK sampling was performed for up to 14 days (336 h). Results Simulation of a single intravenous infusion of rIX-FP (25-75 IU kg-1 ) predicted that the median trough exogenous FIX activity levels would remain > 5 IU dL-1 for up to 16 days in adolescents/adults aged ≥ 12 years, up to 12 days in children aged 6 to < 12 years, and up to 9.5 days in children aged < 6 years. For steady-state dosing, the median trough exogenous FIX activity levels were maintained at > 5 IU dL-1 for the duration of the dosing interval for the 25, 35 and 40 IU kg-1 weekly regimens and for 75 IU kg-1 every 14 days in adolescents/adults, and for the 35 and 40 IU kg-1 weekly regimens in children. Conclusion The population PK model developed here correlates well with observed clinical data and supports prolonged dosing of rIX-FP with intervals of up to 2 weeks.
Collapse
|
9
|
Comparative pharmacokinetics of rVIII-SingleChain and octocog alfa (Advate(®) ) in patients with severe haemophilia A. Haemophilia 2016; 22:730-8. [PMID: 27434619 DOI: 10.1111/hae.12985] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/25/2016] [Indexed: 01/16/2023]
Abstract
BACKGROUND rVIII-SingleChain, a novel recombinant factor VIII (rFVIII), has been designed as a B-domain truncated construct with covalently bonded heavy and light chains, aiming to increase binding affinity to von Willebrand factor (VWF). Preclinical studies confirmed greater affinity for VWF, giving improved pharmacokinetic and pharmacodynamic properties compared with full-length rFVIII. AIM To investigate the pharmacokinetics of rVIII-SingleChain and compare them against those of full-length rFVIII. METHODS This study enrolled 27 patients with severe haemophilia A in the AFFINITY clinical trial programme. After a 4-day washout period, all patients received a single infusion of 50 IU kg(-1) octocog alfa (Advate(®) ); after a ≥4-day postinfusion washout period, they received a single infusion of 50 IU kg(-1) rVIII-SingleChain. Blood samples for pharmacokinetic assessments of each product were collected before infusion (predose) and at 0.5, 1, 4, 8, 10, 24, 32, 48 and 72 h postinfusion for both products. RESULTS rVIII-SingleChain had a longer mean half-life (t1/2 ) (14.5 vs. 13.3 h), lower mean clearance (CL) (2.64 vs. 3.68 mL h(-1) kg(-1) ), higher mean residence time (20.4 vs. 17.1 h) and larger mean AUCinf (2090 vs. 1550 IU?h dL(-1) ) than octocog alfa, respectively. The mean AUCinf after rVIII-SingleChain infusion was ~35% larger than after octocog alfa. A similar pattern was observed for AUC0-last . No serious adverse events or inhibitors were reported. CONCLUSIONS rVIII-SingleChain has a favourable pharmacokinetic profile compared with octocog alfa and was well tolerated. The prolonged t1/2 , larger AUC and reduced CL of rVIII-SingleChain may permit longer dosing intervals, thereby improving patient adherence to prophylactic treatment.
Collapse
|
10
|
Abstract
BACKGROUND The oral factor Xa inhibitor edoxaban has demonstrated safety and efficacy in stroke prevention in patients with atrial fibrillation and in the treatment and secondary prevention of venous thromboembolism. This study investigated the reversal of edoxaban's effects on bleeding measures and biomarkers by using a 4-factor prothrombin complex concentrate (4F-PCC). METHODS AND RESULTS This was a phase 1 study conducted at a single site. This was a double-blind, randomized, placebo-controlled, 2-way crossover study to determine the reversal effect of descending doses of 4F-PCC on bleeding duration and bleeding volume following edoxaban treatment. A total of 110 subjects (17 in part 1, 93 in part 2) were treated. Intravenous administration of 4F-PCC 50, 25, or 10 IU/kg following administration of edoxaban (60 mg) dose-dependently reversed edoxaban's effects on bleeding duration and endogenous thrombin potential, with complete reversal at 50 IU/kg. Effects on prothrombin time were partially reversed at 50 IU/kg. A similar trend was seen for bleeding volume. CONCLUSIONS The 4F-PCC dose-dependently reversed the effects of edoxaban (60 mg), with complete reversal of bleeding duration and endogenous thrombin potential and partial reversal of prothrombin time following 50 IU/kg. Edoxaban alone and in combination with 4F-PCC was safe and well tolerated in these healthy subjects. A dose of 50 IU/kg 4F-PCC may be suitable for reversing edoxaban anticoagulation. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT02047565.
Collapse
|
11
|
Biochemical comparison of four commercially available C1 esterase inhibitor concentrates for treatment of hereditary angioedema. Transfusion 2014; 54:2566-73. [PMID: 24805006 PMCID: PMC4285325 DOI: 10.1111/trf.12678] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2013] [Revised: 02/25/2014] [Accepted: 02/25/2014] [Indexed: 12/28/2022]
Abstract
Background For safe and efficacious treatment of hereditary angioedema, C1 esterase inhibitor (C1-INH) concentrates should have high purity and high amounts of functional protein. As no pharmacopoeia requirements exist for C1-INH concentrate lot release, biochemical characteristics as declared by the manufacturers may not be compared directly. This study compared the characteristics and purity profiles of four commercially available C1-INH concentrates. Study Design and Methods The analysis included one transgenic (Ruconest) and three plasma-derived (Berinert, Cetor, Cinryze) C1-INH concentrates. C1-INH antigen concentration was determined by nephelometry, total protein (specific activity) with a Bradford assay, purity by size-exclusion chromatography and gel electrophoresis, and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was performed. Results Functionality (inversely proportional to antigen-to-activity ratio) was lowest for Ruconest (1.67), followed by Cetor (1.42), Berinert (1.24), and Cinryze (1.22). Specific activity (U/mg) and purity (%) were highest in Ruconest (12.13; 98.6) and Berinert (11.57; 97.0), followed by Cinryze (10.41; 89.5) and Cetor (9.01; 88.6). Main protein bands were found for all plasma-derived products at approximately 105 kDa, and for Ruconest, at approximately 98 kDa. Additional bands in the plasma-derived products were α1-antichymotrypsin, ceruloplasmin, Factor C3 (Cinryze/Cetor), and immunoglobulin heavy constant mu (Berinert). Conclusion Ruconest has a very high purity profile but is not identical to the human C1-INH protein. Of the plasma-derived products, Berinert has the highest purity profile. The impact of the nontherapeutic proteins identified has not yet been evaluated. For harmonization of the analysis for drug release, we recommend the establishment of regulatory requirements for purity determination and the implementation of threshold levels in C1-INH concentrates.
Collapse
|
12
|
Pharmacokinetics of plasma-derived C1-esterase inhibitor after subcutaneous versus intravenous administration in subjects with mild or moderate hereditary angioedema: the PASSION study. Transfusion 2013; 54:1552-61. [PMID: 24266596 PMCID: PMC4215596 DOI: 10.1111/trf.12501] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2013] [Revised: 10/23/2013] [Accepted: 10/23/2013] [Indexed: 12/11/2022]
Abstract
Background Hereditary angioedema (HAE) is a rare disease caused by C1-esterase inhibitor (C1-INH) deficiency, characterized by periodic attacks of acute edema affecting subcutaneous (SC) tissues and mucous membranes. Human C1-INH concentrate given intravenously (IV) is effective and safe, but venous access may be difficult. We compared SC and IV administration of human pasteurized C1-INH concentrate with respect to pharmacokinetics, pharmacodynamics, and safety. Study Design and Methods This was a prospective, randomized, open-label, crossover study. Twenty-four subjects with mild or moderate HAE were randomly assigned during an attack-free interval to receive 1000 units of human pasteurized C1-INH concentrate IV or SC. Plasma levels of C1-INH activity and antigen, C4 antigen, cleaved high-molecular-weight kininogen (clHK), and C1-INH antibodies were measured. Results The mean relative bioavailability of functional C1-INH after SC administration was 39.7%. Maximum C1-INH activity after SC administration occurred within 48 hours and persisted longer than after IV administration. C4 antigen levels increased and clHK levels decreased after IV and SC administration, indicating the pharmacodynamic action of C1-INH. The mean half-life of functional C1-INH was 62 hours after IV administration and 120 hours after SC administration (p = 0.0595). C1-INH concentrate was safe and well tolerated when administered via both routes. As expected, SC administration resulted in a higher incidence of injection site reactions, all of which were mild. Conclusion With a relative bioavailability of 39.7%, SC administration of human pasteurized C1-INH yields potentially clinically relevant and sustained plasma levels of C1-INH and is safe and well tolerated.
Collapse
|
13
|
Clinical hyperthermia of prostate cancer using magnetic nanoparticles: Presentation of a new interstitial technique. Int J Hyperthermia 2009; 21:637-47. [PMID: 16304715 DOI: 10.1080/02656730500158360] [Citation(s) in RCA: 385] [Impact Index Per Article: 25.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
Abstract
The aim of this pilot study was to evaluate whether the technique of magnetic fluid hyperthermia can be used for minimally invasive treatment of prostate cancer. This paper presents the first clinical application of interstitial hyperthermia using magnetic nanoparticles in locally recurrent prostate cancer. Treatment planning was carried out using computerized tomography (CT) of the prostate. Based on the individual anatomy of the prostate and the estimated specific absorption rate (SAR) of magnetic fluids in prostatic tissue, the number and position of magnetic fluid depots required for sufficient heat deposition was calculated while rectum and urethra were spared. Nanoparticle suspensions were injected transperineally into the prostate under transrectal ultrasound and flouroscopy guidance. Treatments were delivered in the first magnetic field applicator for use in humans, using an alternating current magnetic field with a frequency of 100 kHz and variable field strength (0-18 kA m(-1)). Invasive thermometry of the prostate was carried out in the first and last of six weekly hyperthermia sessions of 60 min duration. CT-scans of the prostate were repeated following the first and last hyperthermia treatment to document magnetic nanoparticle distribution and the position of the thermometry probes in the prostate. Nanoparticles were retained in the prostate during the treatment interval of 6 weeks. Using appropriate software (AMIRA), a non-invasive estimation of temperature values in the prostate, based on intra-tumoural distribution of magnetic nanoparticles, can be performed and correlated with invasively measured intra-prostatic temperatures. Using a specially designed cooling device, treatment was well tolerated without anaesthesia. In the first patient treated, maximum and minimum intra-prostatic temperatures measured at a field strength of 4.0-5.0 kA m(-1) were 48.5 degrees C and 40.0 degrees C during the 1st treatment and 42.5 degrees C and 39.4 degrees C during the 6th treatment, respectively. These first clinical experiences prompted us to initiate a phase I study to evaluate feasibility, toxicity and quality of life during hyperthermia using magnetic nanoparticles in patients with biopsy-proven local recurrence of prostate cancer following radiotherapy with curative intent. To the authors' knowledge, this is the first report on clinical application of interstitial hyperthermia using magnetic nanoparticles in the treatment of human cancer.
Collapse
|
14
|
123I-IMT SPECT for evaluation of the response to radiation therapy in high grade gliomas: a feasibility study. Br J Radiol 2007; 80:274-8. [PMID: 17121760 DOI: 10.1259/bjr/28164599] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Assessing response to radiation therapy in patients with high grade gliomas is needed upon making decisions toward further therapy strategies. Currently used standard imaging tools such as CT and MRI are not sensitive enough to detect early therapy effects. We prospectively investigated if single photon emission computed tomography (SPECT) using radiolabelled amino acid derivate (123)I-methyltyrosine (IMT) would be useful for this aim. 10 patients with histologically proven high grade gliomas, who were candidates for radiation therapy, were enrolled in this investigation. All patients were examined by IMT SPECT before radiation therapy and 4 weeks after the initiation of the hypofractionated application of 40 Gy. Patients were followed up for 39 months; the tumours to background ratios (T/B) for IMT under/before radiation therapy were correlated to survival times. Initially, SPECT depicted an abnormal intratumoural IMT uptake in all patients (mean T/B ratios 1.37-1.87). In four out of 10 patients, the mean T/B ratios decreased by more than 10% under radiation therapy. In six other patients, the BQ decreased by less than 10% or increased. There were no significant correlations between the degree of changes in T/B and survival (r = -0.1, p = 0.973). Serial IMT SPECT measurements allow detection of changes in amino acid accumulation in high-grade gliomas under radiation therapy. However, these changes seem to possess no prognostic value in respect to survival prediction.
Collapse
|
15
|
Methods and potentials of magnetic resonance imaging for monitoring radiofrequency hyperthermia in a hybrid system. Int J Hyperthermia 2005; 21:497-513. [PMID: 16147436 DOI: 10.1080/02656730500070102] [Citation(s) in RCA: 73] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
Abstract
INTRODUCTION Non-invasive thermometry (NIT) is a valuable and probably indispensable tool for further development of radiofrequency (RF) hyperthermia. A hybridization of an MRI scanner with a hyperthermia system is necessary for a real-time NIT. The selection of the best thermographic method is difficult, because many parameters and attributes have to be considered. METHODS In the hybrid system (Siemens Symphony/BSD-2000-3D) the standard methods for NIT were tested such as T1, diffusion (ADC: apparent diffusion coefficient) and proton-resonance-frequency shift (PFS) method. A series of three-dimensional datasets was acquired with different gradient-echo sequences, diffusion-weighted EPI spin-echo sequences and calculated MR-temperatures in the software platform AMIRA-HyperPlan. In particular for the PFS-method, corrective methods were developed and tested with respect to drift and other disturbances. Experiments were performed in phantoms and the results compared with direct temperature measurements. Then the procedures were transferred to clinical applications in patients with larger tumours of the lower extremity or the pelvis. RESULTS Heating experiments and MR-thermography in a homogeneous cylindrical phantom give an excellent survey over the potentials of the methods. Under clinical conditions all these methods have difficulties due to motion, physiological changes, inhomogeneous composition and susceptibility variations in human tissues. The PFS-method is most stable in patients yielding reasonable MR temperature distributions and time curves for pelvic and lower extremity tumours over realistic treatment times of 60-90 min. Pooled data exist for rectal tumour recurrencies and soft tissue sarcomas. The fat tissue can be used for drift correction in these patients. T1 and diffusion-dependent methods appear less suitable for these patients. The standard methods have different sensitivities with respect to the various error sources. The advantages and pitfalls of every method are discussed with respect to the literature and illustrated by the phantom and patient measurements. CONCLUSIONS MR-controlled RF hyperthermia in a hybrid system is well established in phantoms and already feasible for patients in the pelvic and lower extremity region. Under optimal conditions the temperature accuracy might be in the range of 0.5 degrees C. However a variety of developments, especially sequences and post-processing modules, are still required for the clinical routine.
Collapse
|
16
|
Clinical hyperthermia of prostate cancer using magnetic nanoparticles: presentation of a new interstitial technique. Int J Hyperthermia 2005. [PMID: 16304715 DOI: 10.1080/02656730500158] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/30/2022] Open
Abstract
The aim of this pilot study was to evaluate whether the technique of magnetic fluid hyperthermia can be used for minimally invasive treatment of prostate cancer. This paper presents the first clinical application of interstitial hyperthermia using magnetic nanoparticles in locally recurrent prostate cancer. Treatment planning was carried out using computerized tomography (CT) of the prostate. Based on the individual anatomy of the prostate and the estimated specific absorption rate (SAR) of magnetic fluids in prostatic tissue, the number and position of magnetic fluid depots required for sufficient heat deposition was calculated while rectum and urethra were spared. Nanoparticle suspensions were injected transperineally into the prostate under transrectal ultrasound and flouroscopy guidance. Treatments were delivered in the first magnetic field applicator for use in humans, using an alternating current magnetic field with a frequency of 100 kHz and variable field strength (0-18 kA m(-1)). Invasive thermometry of the prostate was carried out in the first and last of six weekly hyperthermia sessions of 60 min duration. CT-scans of the prostate were repeated following the first and last hyperthermia treatment to document magnetic nanoparticle distribution and the position of the thermometry probes in the prostate. Nanoparticles were retained in the prostate during the treatment interval of 6 weeks. Using appropriate software (AMIRA), a non-invasive estimation of temperature values in the prostate, based on intra-tumoural distribution of magnetic nanoparticles, can be performed and correlated with invasively measured intra-prostatic temperatures. Using a specially designed cooling device, treatment was well tolerated without anaesthesia. In the first patient treated, maximum and minimum intra-prostatic temperatures measured at a field strength of 4.0-5.0 kA m(-1) were 48.5 degrees C and 40.0 degrees C during the 1st treatment and 42.5 degrees C and 39.4 degrees C during the 6th treatment, respectively. These first clinical experiences prompted us to initiate a phase I study to evaluate feasibility, toxicity and quality of life during hyperthermia using magnetic nanoparticles in patients with biopsy-proven local recurrence of prostate cancer following radiotherapy with curative intent. To the authors' knowledge, this is the first report on clinical application of interstitial hyperthermia using magnetic nanoparticles in the treatment of human cancer.
Collapse
|
17
|
Magnetic Fluid Hyperthemia (MFH) as an adjuvant therapy in the treatment of malignant gliomas. AKTUELLE NEUROLOGIE 2004. [DOI: 10.1055/s-2004-833341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
18
|
The frequent Marburg I polymorphism impairs the pro-urokinase activating potency of the factor VII activating protease (FSAP). Blood Coagul Fibrinolysis 2002; 13:433-41. [PMID: 12138371 DOI: 10.1097/00001721-200207000-00008] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
The recently reported plasmatic, Factor Seven Activating Protease (FSAP), has also been found to be a potent activator of pro-urokinase [single-chain plasminogen activator, urinary type (scuPA)]. An initial epidemiological study surprisingly showed that plasmas of 5-10% of healthy blood donors had an impaired potential to activate scuPA. Analysis of the respective genomic DNAs revealed one particular single nucleotide polymorphism of FSAP resulting in an identical amino acid exchange (G511E), which correlates with the reduced activities. The corresponding mutation was named FSAP Marburg I. Thrombelastographies of wild-type and mutant plasmas were performed, facilitating the auto-activation of the intrinsic FSAP pro-enzymes by addition of dextran sulfate (DXS) and accelerated clot lysis by addition of scuPA. On these conditions, tissue-factor-induced coagulation revealed that clot lysis was significantly delayed in the Marburg I mutant plasmas as compared with wild-type plasmas. Furthermore, in the presence of DXS and scuPA, a FSAP-deficient plasma revealed significantly prolonged plasma clot lysis times, whereas the addition of purified FSAP pro-enzyme plus scuPA reversed this effect. These results support the hypothesis that FSAP contributes to the scuPA-dependent plasma fibrinolytic potential, which can be impaired in plasmas containing the FSAP Marburg I polymorphism, for instance.
Collapse
|
19
|
Quantitation of the factor VII- and single-chain plasminogen activator-activating protease in plasmas of healthy subjects. Blood Coagul Fibrinolysis 2001; 12:375-83. [PMID: 11505081 DOI: 10.1097/00001721-200107000-00007] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Plasma samples of 189 healthy subjects were investigated for antigen levels of the recently reported factor VII- and single-chain plasminogen activator-activating protease (FSAP) and the corresponding pro-urokinase activating potencies. While the age of donors had no significant effect on the investigated parameters, female plasmas revealed a trend to higher antigen contents and activity levels. Surprisingly, as much as 9% of all samples contained significantly reduced single-chain urinary plasminogen activator activating potential, whereas antigen concentrations were normal. Additionally, 1% of the plasmas was found to decrease in both FSAP antigen and activity contents. FSAP of three subjects displaying reduced activities throughout a follow-up period of 6 months were purified from plasmas and were characterized. As compared with pool plasma derived FSAP, investigation of the individual preparations confirmed their reduced potency to activate pro-urokinase. However, factor VII activation was not affected. It is speculated that the FSAP binding site for single-chain plasminogen activators is affected, potentially by as yet unknown polymorphism(s) or mutation(s).
Collapse
|
20
|
Factor VII and single-chain plasminogen activator-activating protease: activation and autoactivation of the proenzyme. EUROPEAN JOURNAL OF BIOCHEMISTRY 2001; 268:3789-96. [PMID: 11432747 DOI: 10.1046/j.1432-1327.2001.02285.x] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Structural and biological characteristics of a recently described plasma serine protease, which displayed factor VII as well as pro-urokinase-activating properties in vitro, indicated a dual role for this factor VII-activating protease (FSAP) in hemostasis. Only the active protease (two-chain FSAP) has been isolated from plasma and from a prothrombin complex concentrate, whereas activators of the proenzyme have not been identified so far. After purification of the FSAP proenzyme from cryo-poor plasma by adsorption to an immobilized mAb and subsequent ion-exchange chromatography, activation to generate two-chain FSAP was followed by a direct chromogenic assay as well as by the ability of two-chain FSAP to activate pro-urokinase. Purified single-chain FSAP underwent autoactivation leading to the typical protease two-chain pattern and subsequent degradation products, as demonstrated by Western-blotting analysis using a site-specific mAb. This autoactivation was significantly enhanced in the presence of heparin, whereas Ca2+ ions stabilized single-chain FSAP (the proenzyme) resulting in slower autoactivation kinetics. Correspondingly, the heparin-augmented reaction, which was associated with autodegradation particularly of the protease domain, was slowed down by co-incubation with Ca2+. Of the other proteases and cofactors tested, only urokinase (uPA) was able to generate the typical two-chain FSAP pattern. Studies with different forms of uPA suggest that the catalytic activity of pro-urokinase/uPA is needed to activate single-chain FSAP, indicating that it is the only hemostatic protease that can act as a physiological activator of FSAP.
Collapse
|
21
|
Abstract
A serine protease isolated from plasma sharing structural characteristics with a hepatocyte growth factor activator-like protease has been demonstrated recently to activate FVII. Accordingly, it was named 'FVII activator'. Until now an impact of this protease on the fibrinolytic system has not been reported. We islolated the protease from cryo-poor plasma by subsequent ion exchange chromatography and adsorption to immobilized heparin and/or aprotinin. Incubation of single-chain plasminogen activators (sc-PAs) with the FVII activator revealed significant activation of urokinase sc-PA (scu-PA) and tissue sc-PA (sct-PA) in vitro. It was enhanced in the presence of calcium and heparin. Compared to kallikrein, a more efficient activation of scu-PA was observed, whereas sct-PA appeared to be a poorer substrate for the FVI activator. At low protease concentrations and in the presence of heparin the scu-PA activation was comparable to plasmin. Employing recalcified whole blood thrombelastography, the lysis of initially formed fibrin was observed after addition of a combination of scu-PA and the FVII activator, whereas the scu-PA alone had a negligible effect at the concentration used. The study results as presented demonstrate that the FVII activator is a potent activator of sc-PAs in vitro. Whether it plays a physiological role in fibrinolysis deserves further investigation. Its comparatively high affinity to heparin assumes a function in cell surface or matrix events.
Collapse
|
22
|
A protease isolated from human plasma activating factor VII independent of tissue factor. Blood Coagul Fibrinolysis 1999; 10:471-9. [PMID: 10636458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/15/2023]
Abstract
An activity detected in a prothrombin complex concentrate, termed 'thrombin-like' due to its amidolytic properties, was recently reported by another working group. This serine-protease revealed partial structural homology with a 'hepatocyte growth factor activator'. An impact of this protease on coagulation has not yet been described. The protease was isolated from plasma fractions by ion exchange chromatography and adsorption to immobilized heparin and/or aprotinin. Clotting tests including the FVIIa-rTF assay were performed employing coagulometry. A monoclonal antibody-derived F(ab')2 to FVIII was used to investigate the FVIII bypassing activity (FEIBA). The identity of the-protease with the so-called 'thrombin-like' protease was supported by sequencing of the amino-termini. Its amidolytic activity was significantly enhanced in the presence of calcium and/or heparin. Incubation with purified FVII revealed the generation of FVIIa, but was prevented by pre-incubation of the protease with aprotinin. In contrast, purified FV and FVIII were inactivated. Studying coagulation parameters, clotting times like plasma recalcification times and the prothrombin times were found to be shortened by addition of the protease. Employing a FVIII-inhibitory F(ab')2 and enhancing clotting times significantly, FEIBA of the protease was found. We demonstrated that the isolated protease activates FVII independent of tissue factor. Net acceleration of coagulation was found in several global clotting assays resulting in an in vitro FEIBA. The physiological relevance of these findings deserves further investigation.
Collapse
|
23
|
Influence of folic acid, pyridoxal phosphate and cobalamin on plasma homocyst(e)ine levels and the susceptibility of low-density lipoprotein to ex-vivo oxidation. Eur J Med Res 1999; 4:425-32. [PMID: 10527956] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/14/2023] Open
Abstract
Mild hyperhomocyst(e)inaemia is a risk factor for atherosclerotic vascular disease. In-vitro studies have shown that autooxidation of homocyst(e)ine is accompanied by the generation of oxygen radicals. This may lead to oxidative modification of low-density lipoproteins (LDL) and promote atherosclerotic vascular lesions. In male patients with peripheral arterial occlusive disease we determined fasting and post methionine load homocyst(e)ine levels by high performance liquid chromatography and the susceptibility of their LDL particles to ex-vivo oxidation by continously measuring the conjugated diene production induced by incubation with copper ions. Oxidation resistance (expressed as lag time), maximal oxidation rate, and extent of oxidation (expressed of total diene production) of LDL from patients with normal or mildly elevated homocyst(e)ine levels did not differ significantly. Folic acid, pyridoxal phosphate and cobalamin supplementation significantly decreased plasma homocyst(e)ine levels in hyperhomocyst(e)inaemic patients. This went along with a significant decrease in the extent of LDL oxidation and additionally increased HDL-cholesterol levels. The clinical relevance of these findings for the long-term course of atherosclerotic vascular disorders has to be determined by intervention studies.
Collapse
|
24
|
Determination of total homocysteine in human plasma by isocratic high-performance liquid chromatography. EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY : JOURNAL OF THE FORUM OF EUROPEAN CLINICAL CHEMISTRY SOCIETIES 1997; 35:687-91. [PMID: 9352231 DOI: 10.1515/cclm.1997.35.9.687] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
A simple, sensitive and precise isocratic HPLC method for the determination of total homocysteine in human plasma is described. The thiol compounds were liberated from plasma proteins by reduction with tri-n-butylphosphine and derivatized with a thiol-specific fluorogenic marker, 7-fluoro-benzo-2-oxa-1,3-diazole-4-sulphonate. The derivatives were separated isocratically within 7 min by reversed-phase HPLC using a Superspher 100 RP-18 column as stationary phase. By using this approach more than 200 samples a day can be assayed for total homocysteine. The method was linear up to 100 mumol/l and proved to be sensitive with a detection limit of 0.1 mumol/l and the lowest limit of reliable quantification of 0.5 mumol/l for homocysteine in buffer. Intra- and inter-assay coefficients of variation were both < 4% at a concentration of 10 mumol/l homocysteine. Similar results were obtained for homocysteine concentrations between 0.5 and 100 mumol/l. The analytical recovery for these concentrations ranged from 94.9 to 117.0%. As compared to other protocols published so far, this modified method is less complicated but equally sensitive and reproducible and allows a rapid determination of total homocysteine and cysteine in human plasma under routine conditions.
Collapse
|