1
|
Yu J, Javier D, Yaseen MA, Nitin N, Richards-Kortum R, Anvari B, Wong MS. Self-assembly synthesis, tumor cell targeting, and photothermal capabilities of antibody-coated indocyanine green nanocapsules. J Am Chem Soc 2010; 132:1929-38. [PMID: 20092330 PMCID: PMC2834762 DOI: 10.1021/ja908139y] [Citation(s) in RCA: 241] [Impact Index Per Article: 16.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
New colloidal materials that can generate heat upon irradiation are being explored for photothermal therapy as a minimally invasive approach to cancer treatment. The near-infrared dye indocyanine green (ICG) could serve as a basis for such a material, but its encapsulation and subsequent use are difficult to carry out. We report the three-step room-temperature synthesis of approximately 120-nm capsules loaded with ICG within salt-cross-linked polyallylamine aggregates, and coated with antiepidermal growth factor receptor (anti-EGFR) antibodies for tumor cell targeting capability. We studied the synthesis conditions such as temperature and water dilution to control the capsule size and characterized the size distribution via dynamic light scattering and scanning electron microscopy. We further studied the specificity of tumor cell targeting using three carcinoma cell lines with different levels of EGFR expression and investigated the photothermal effects of ICG containing nanocapsules on EGFR-rich tumor cells. Significant thermal toxicity was observed for encapsulated ICG as compared to free ICG at 808 nm laser irradiation with radiant exposure of 6 W/cm(2). These results illustrate the ability to design a colloidal material with cell targeting and heat generating capabilities using noncovalent chemistry.
Collapse
|
Research Support, N.I.H., Extramural |
15 |
241 |
2
|
Arya M, Anvari B, Romo GM, Cruz MA, Dong JF, McIntire LV, Moake JL, López JA. Ultralarge multimers of von Willebrand factor form spontaneous high-strength bonds with the platelet glycoprotein Ib-IX complex: studies using optical tweezers. Blood 2002; 99:3971-7. [PMID: 12010796 DOI: 10.1182/blood-2001-11-0060] [Citation(s) in RCA: 224] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Ultralarge von Willebrand factor (ULVWF) multimers have been implicated in the pathogenesis of the catastrophic microangiopathic disorder, thrombotic thrombocytopenic purpura. Spontaneous ULVWF binding to platelets has been ascribed to increased avidity due to the greatly increased number of binding sites for platelets (the A1 domain) per molecule. To address the mechanism of enhanced ULVWF binding to platelets, we used optical tweezers to study the unbinding forces from the glycoprotein Ib-IX (GP Ib-IX) complex of plasma VWF, ULVWF, and isolated A1 domain. The unbinding force was defined as the minimum force required to pull ligand-coated beads away from their attachment with GP Ib-IX-expressing cells. Beads coated with plasma VWF did not bind to the cells spontaneously, requiring the modulators ristocetin or botrocetin. The force required to break the ristocetin- and botrocetin-induced plasma VWF-GP Ib-IX bonds occurred in integer multiples of 6.5 pN and 8.8 pN, respectively, depending on the number of bonds formed. In contrast, beads coated with either ULVWF or A1 domain bound the cells in the absence of modulators, with bond strengths in integer multiples of approximately 11.4 pN for both. Thus, in the absence of shear stress, ULVWF multimers form spontaneous high-strength bonds with GP Ib-IX, while plasma VWF requires exogenous modulators. The strength of individual bonds formed with GP Ib-IX was similar for both ULVWF and the isolated A1 domain and greater than those of plasma VWF induced by either modulator. Therefore, we suggest that the conformational state of ULVWF multimers is more critical than their size for interaction with platelets.
Collapse
|
|
23 |
224 |
3
|
Padilla A, Moake JL, Bernardo A, Ball C, Wang Y, Arya M, Nolasco L, Turner N, Berndt MC, Anvari B, López JA, Dong JF. P-selectin anchors newly released ultralarge von Willebrand factor multimers to the endothelial cell surface. Blood 2003; 103:2150-6. [PMID: 14630802 DOI: 10.1182/blood-2003-08-2956] [Citation(s) in RCA: 162] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
von Willebrand factor (VWF) released from endothelium is ultralarge (UL) and hyperreactive. If released directly into plasma, it can spontaneously aggregate platelets, resulting in systemic thrombosis. This disastrous consequence is prevented by the ADAMTS13 (ADisintegrin and Metalloprotease with ThromboSpondin motif) cleavage of ULVWF into smaller, less active forms. We previously showed that ULVWF, on release, forms extremely long stringlike structures. ADAMTS13 cleaves these strings under flow significantly faster than it does under static conditions. As ULVWF tethering to endothelium is important for its rapid proteolysis, we investigated 2 molecules for their potential to anchor the ULVWF strings: P-selectin and integrin alpha v beta 3. We demonstrated that P-selectin anchors ULVWF to endothelium by several means. First, Chinese hamster ovary (CHO) cells expressing P-selectin specifically adhered to immobilized ULVWF and ULVWF-coated beads to immobilized P-selectin. Second, an anti-VWF antibody coimmunoprecipitates P-selectin from the histamine-activated endothelial cells. Third, P-selectin antibody or soluble P-selectin, but not a alpha v beta 3 antibody, RGDS peptide, or heparin, blocked the formation of ULVWF strings. Fourth, P-selectin expression was in clusters predominantly along the ULVWF strings. Finally, the strength of the minimal ULVWF-P-selectin bond was measured to be 7.2 pN. We, therefore, conclude that P-selectin may anchor ULVWF strings to endothelial cells and facilitate their cleavage by ADAMTS13.
Collapse
|
Research Support, U.S. Gov't, P.H.S. |
22 |
162 |
4
|
Nelson JS, Milner TE, Anvari B, Tanenbaum BS, Svaasand LO, Kimel S. Dynamic epidermal cooling in conjunction with laser-induced photothermolysis of port wine stain blood vessels. Lasers Surg Med 1996; 19:224-9. [PMID: 8887927 DOI: 10.1002/(sici)1096-9101(1996)19:2<224::aid-lsm15>3.0.co;2-6] [Citation(s) in RCA: 119] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
When a cryogen spurt is applied to the skin surface for an appropriately short period of time (on the order of tens of milliseconds), the spatial distribution of cooling remains localized in the normal overlying epidermis, while leaving the temperature of the deeper port wine stain (PWS) blood vessels unchanged. Furthermore, cooling continues after pulsed laser exposure as cryogen remaining on the surface evaporates and removes heat deposited by light absorption in epidermal melanin. An additional advantage of dynamic cooling is a reduction in the level of pain and discomfort associated with flashlamp-pumped pulsed dye laser therapy of PWS. Preliminary clinical studies and supporting theoretical calculations demonstrate the feasibility of selective epidermal cooling while achieving photothermolysis of blood vessels during pulsed laser treatment of PWS.
Collapse
|
|
29 |
119 |
5
|
Li Z, Anvari B, Takashima M, Brecht P, Torres JH, Brownell WE. Membrane tether formation from outer hair cells with optical tweezers. Biophys J 2002; 82:1386-95. [PMID: 11867454 PMCID: PMC1301940 DOI: 10.1016/s0006-3495(02)75493-3] [Citation(s) in RCA: 111] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
Optical tweezers were used to characterize the mechanical properties of the outer hair cell (OHC) plasma membrane by pulling tethers with 4.5-microm polystyrene beads. Tether formation force and tether force were measured in static and dynamic conditions. A greater force was required for tether formations from OHC lateral wall (499 +/- 152 pN) than from OHC basal end (142 +/- 49 pN). The difference in the force required to pull tethers is consistent with an extensive cytoskeletal framework associated with the lateral wall known as the cortical lattice. The apparent plasma membrane stiffness, estimated under the static conditions by measuring tether force at different tether length, was 3.71 pN/microm for OHC lateral wall and 4.57 pN/microm for OHC basal end. The effective membrane viscosity was measured by pulling tethers at different rates while continuously recording the tether force, and estimated in the range of 2.39 to 5.25 pN x s/microm. The viscous force most likely results from the viscous interactions between plasma membrane lipids and the OHC cortical lattice and/or integral membrane proteins. The information these studies provide on the mechanical properties of the OHC lateral wall is important for understanding the mechanism of OHC electromotility.
Collapse
|
research-article |
23 |
111 |
6
|
Anvari B, Milner TE, Tanenbaum BS, Kimel S, Svaasand LO, Nelson JS. Selective cooling of biological tissues: application for thermally mediated therapeutic procedures. Phys Med Biol 1995; 40:241-52. [PMID: 7708851 DOI: 10.1088/0031-9155/40/2/003] [Citation(s) in RCA: 73] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
The ability to control the degree and spatial distribution of cooling in biological tissues during a thermally mediated therapeutic procedure would be useful for several biomedical applications of lasers. We present a theory based on the solution of the heat conduction equation that demonstrates the feasibility of selectively cooling biological tissues. Model predictions are compared with infrared thermal measurements of in vivo human skin in response to cooling by a cryogen spurt. The presence of a boundary layer, undergoing a liquid-vapour phase transition, is associated with a relatively large thermal convection coefficient (approximately 40 kW m-2 K-1), which gives rise to the observed surface temperature reductions (30-40 degrees C). The degree and the spatial-temporal distribution of cooling are shown to be directly related to the cryogen spurt duration.
Collapse
|
|
30 |
73 |
7
|
Yaseen MA, Yu J, Jung B, Wong MS, Anvari B. Biodistribution of encapsulated indocyanine green in healthy mice. Mol Pharm 2009; 6:1321-32. [PMID: 19799463 DOI: 10.1021/mp800270t] [Citation(s) in RCA: 70] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
Indocyanine green (ICG) is a fluorescent probe used in various optically mediated diagnostic and therapeutic applications. However, utility of ICG remains limited by its unstable optical properties and nonspecific localization. We have encapsulated ICG within electrostatically assembled mesocapsules (MCs) to explore its potential for targeted optical imaging and therapy. In this study, we investigate how the surface coating and size of the MCs influences ICG's biodistribution in vivo. ICG was administered intravenously to Swiss Webster mice as a free solution or encapsulated within either 100 nm diameter MCs coated with dextran; 500 nm diameter MCs coated with dextran; or 100 nm diameter MCs coated with 10 nm ferromagnetic iron oxide nanoparticles, themselves coated with polyethylene glycol. ICG was extracted from harvested blood and organs at various times and its amount quantified with fluorescence measurements. MCs containing ICG accumulated in organs of the reticuloendothelial system, namely, the liver and spleen, as well as the lungs. The circulation kinetics of ICG appeared unaffected by encapsulation; however, the deposition within organs other than the liver suggests a different biodistribution mechanism. Results suggest that the capsules' coating influences their biodistribution to a greater extent than their size. The MC encapsulation system allows for delivery of ICG to organs other than the liver, enabling the potential development of new optical imaging and therapeutic strategies.
Collapse
|
Research Support, U.S. Gov't, Non-P.H.S. |
16 |
70 |
8
|
Anvari B, Tanenbaum BS, Milner TE, Kimel S, Svaasand LO, Nelson JS. A theoretical study of the thermal response of skin to cryogen spray cooling and pulsed laser irradiation: implications for treatment of port wine stain birthmarks. Phys Med Biol 1995; 40:1451-65. [PMID: 8532758 DOI: 10.1088/0031-9155/40/9/005] [Citation(s) in RCA: 65] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
The successful treatment of port wine stain (PWS) patients undergoing laser therapy is based on selective thermal coagulation of blood vessels without damaging the normal overlying epidermis. Cryogen spray cooling of skin may offer an effective method for minimizing epidermal thermal injury. Inasmuch as the density of melanosomes and depth of PWS blood vessels can vary considerably, an optimum cooling strategy is required on an individual patient basis. We present a theoretical study of the thermal response of various pigmented PWS lesions to spray cooling in conjunction with flashlamp-pumped pulsed dye laser irradiation (585 nm). Results of our model indicate that precooling of skin using tetrafluoroethane as the cryogen spray is sufficient to eliminate epidermal thermal injury when using incident fluences less than 10 J cm-2 and 8 J cm-2 on patients with intermediate and high epidermal melanin content, respectively. Cryogens that have lower boiling points than tetrafluoroethane may allow successful treatment when using fluences equal to or greater than those indicated.
Collapse
|
|
30 |
65 |
9
|
Huang W, Anvari B, Torres JH, LeBaron RG, Athanasiou KA. Temporal effects of cell adhesion on mechanical characteristics of the single chondrocyte. J Orthop Res 2003; 21:88-95. [PMID: 12507584 DOI: 10.1016/s0736-0266(02)00130-4] [Citation(s) in RCA: 60] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Cell adhesion to material surfaces is a fundamental phenomenon in tissue response to implanted devices, and an important consideration in tissue engineering. For example, elucidation of phenomena associated with adhesion of chondrocytes to biomaterials is critical in addressing the difficult problem of articular cartilage regeneration. The first objective of this study was to measure the mechanical adhesiveness characteristics of individual rabbit articular chondrocytes as a function of seeding time to provide further understanding of the cell adhesion process. The second objective was to quantify the force required to separate the plasma membrane from the underlying cytoskeleton as a function of seeding time. After culturing chondrocytes on glass coverslips for 1, 2, 4, 6 h, two biomechanical tests were performed on single chondrocytes: (i) mechanical adhesiveness measurement by the cytodetacher; and (ii) plasma membrane tether formation force measurement by optical tweezers. Cell mechanical adhesiveness increased from 231+/-149 Pa at 1 h to 1085+/-211 Pa at 6 h. The cell contact area with the substrata increased from 161+/-52 microm(2) at 1 h to 369+/-105 microm(2) at 6 h. The tether formation force increased from 232+/-23 pN at 1 h to 591+/-17 pN at 6 h. Moreover, fluorescence staining by rhodamine-phalloidin demonstrated the process of actin spreading within the cytoskeleton from 0.5 to 6 h and allowed for measurement of cell height which was found to decrease from 12.3+/-2.9 microm at 0.5 h to 6.2+/-0.9 microm at 6 h.
Collapse
|
|
22 |
60 |
10
|
Dai T, Pikkula BM, Wang LV, Anvari B. Comparison of human skin opto-thermal response to near-infrared and visible laser irradiations: a theoretical investigation. Phys Med Biol 2004; 49:4861-77. [PMID: 15584524 DOI: 10.1088/0031-9155/49/21/002] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Near-infrared wavelengths are absorbed less by epidermal melanin, and penetrate deeper into human skin dermis and blood than visible wavelengths. Therefore, laser irradiation using near-infrared wavelengths may improve the therapeutic outcome of cutaneous hyper-vascular malformations in moderately to heavily pigmented skin patients and those with large-sized blood vessels or blood vessels extending deeply into the skin. A mathematical model composed of a Monte Carlo algorithm to estimate the distribution of absorbed light, numerical solution of a bio-heat diffusion equation to calculate the transient temperature distribution, and a damage integral based on an empirical Arrhenius relationship to quantify the tissue damage was utilized to investigate the optothermal response of human skin to near-infrared and visible laser irradiations in conjunction with cryogen spray cooling. In addition, the thermal effects of a single continuous laser pulse and micropulse-composed laser pulse profiles were compared. Simulation results indicated that a 940 nm wavelength induces improved therapeutic outcome compared with a 585 and 595 nm wavelengths for the treatment of patients with large-sized blood vessels and moderately to heavily pigmented skin. On the other hand, a 585 nm wavelength shows the best efficacy in treating small-sized blood vessels, as characterized by the largest laser-induced blood vessel damage depth compared with 595 and 940 nm wavelengths. Dermal blood content has a considerable effect on the threshold incident dosage for epidermal damage, while the effect of blood vessel size is minimal. For the same macropulse duration and incident dosage, a micropulse-composed pulse profile results in higher peak temperature at the basal layer of skin epidermis than an ideal single continuous pulse profile.
Collapse
|
|
21 |
53 |
11
|
Pikkula BM, Torres JH, Tunnell JW, Anvari B. Cryogen spray cooling: Effects of droplet size and spray density on heat removal. Lasers Surg Med 2001; 28:103-12. [PMID: 11241515 DOI: 10.1002/lsm.1024] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND AND OBJECTIVE Cryogen spray cooling (CSC) is an effective method to reduce or eliminate non-specific injury to the epidermis during laser treatment of various dermatological disorders. In previous CSC investigations, fuel injectors have been used to deliver the cryogen onto the skin surface. The objective of this study was to examine cryogen atomization and heat removal characteristics of various cryogen delivery devices. STUDY DESIGN/MATERIALS AND METHODS Various cryogen delivery device types including fuel injectors, atomizers, and a device currently used in clinical settings were investigated. Cryogen mass was measured at the delivery device output orifice. Cryogen droplet size profiling for various cryogen delivery devices was estimated by optically imaging the droplets in flight. Heat removal for various cryogen delivery devices was estimated over a range of spraying distances by temperature measurements in an skin phantom used in conjunction with an inverse heat conduction model. RESULTS A substantial range of mass outputs were measured for the cryogen delivery devices while heat removal varied by less than a factor of two. Droplet profiling demonstrated differences in droplet size and spray density. CONCLUSIONS Results of this study show that variation in heat removal by different cryogen delivery devices is modest despite the relatively large difference in cryogen mass output and droplet size. A non-linear relationship between heat removal by various devices and droplet size and spray density was observed.
Collapse
|
|
24 |
51 |
12
|
Anvari B, Milner TE, Tanenbaum BS, Nelson JS. A comparative study of human skin thermal response to sapphire contact and cryogen spray cooling. IEEE Trans Biomed Eng 1998; 45:934-41. [PMID: 9644903 DOI: 10.1109/10.686802] [Citation(s) in RCA: 50] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Surface cooling, in conjunction with various thermally mediated therapeutic procedures, can provide a means to protect superficial tissues from injury while achieving destruction of deeper targeted structures. We have investigated the thermal response of in-vivo human skin to: 1) contact cooling with a sapphire window (6-12 degrees C); and 2) spray cooling with a freon substitute cryogen [tetrafluoroethane; boiling point approximately -26 degrees C at 1 atmospheric pressure (atm)]. Measurements utilizing infrared radiometry show surface temperature reductions from 30 degrees C to 14-19 degrees C are obtained within approximately 1 s in response to sapphire contact cooling. Surface temperature reductions to values between 5 degrees C and -9 degrees C are obtained in response to 20-100-ms cryogen spurts. Computational results, based on fitting the measured radiometric surface temperature to estimate heat transfer parameters, show: 1) temperature reductions remain localized to approximately 200 microns of superficial tissue; and 2) values of heat flux and total energy removed per unit skin surface area at least doubled when using cryogen spray cooling.
Collapse
|
Comparative Study |
27 |
50 |
13
|
Khatibzadeh N, Gupta S, Farrell B, Brownell WE, Anvari B. Effects of cholesterol on nano-mechanical properties of the living cell plasma membrane. SOFT MATTER 2012; 8:8350-8360. [PMID: 23227105 PMCID: PMC3515074 DOI: 10.1039/c2sm25263e] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
In this study, we investigated the effects of membrane cholesterol content on the mechanical properties of cell membranes by using optical tweezers. We pulled membrane tethers from human embryonic kidney cells using single and multi-speed protocols, and obtained time-resolved tether forces. We quantified various mechanical characteristics including the tether equilibrium force, bending modulus, effective membrane viscosity, and plasma membrane-cytoskeleton adhesion energy, and correlated them to the membrane cholesterol level. Decreases in cholesterol concentration were associated with increases in the tether equilibrium force, tether stiffness, and adhesion energy. Tether diameter and effective viscosity increased with increasing cholesterol levels. Disruption of cytoskeletal F-actin significantly changed the tether diameters in both non-cholesterol and cholesterol-manipulated cells, while the effective membrane viscosity was unaffected by F-actin disruption. The findings are relevant to inner ear function where cochlear amplification is altered by changes in membrane cholesterol content.
Collapse
|
research-article |
13 |
48 |
14
|
Brownell WE, Qian F, Anvari B. Cell membrane tethers generate mechanical force in response to electrical stimulation. Biophys J 2010; 99:845-52. [PMID: 20682262 PMCID: PMC3297770 DOI: 10.1016/j.bpj.2010.05.025] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2009] [Revised: 03/25/2010] [Accepted: 05/10/2010] [Indexed: 11/22/2022] Open
Abstract
Living cells maintain a huge transmembrane electric field across their membranes. This electric field exerts a force on the membrane because the membrane surfaces are highly charged. We have measured electromechanical force generation by cell membranes using optically trapped beads to detach the plasma membrane from the cytoskeleton and form long thin cylinders (tethers). Hyperpolarizing potentials increased and depolarizing potentials decreased the force required to pull a tether. The membrane tether force in response to sinusoidal voltage signals was a function of holding potential, tether diameter, and tether length. Membrane electromechanical force production can occur at speeds exceeding those of ATP-based protein motors. By harnessing the energy in the transmembrane electric field, cell membranes may contribute to processes as diverse as outer hair cell electromotility, ion channel gating, and transport.
Collapse
|
Research Support, N.I.H., Extramural |
15 |
47 |
15
|
Yaseen MA, Yu J, Wong MS, Anvari B. Laser-Induced Heating of Dextran-Coated Mesocapsules Containing Indocyanine Green. Biotechnol Prog 2007; 23:1431-40. [PMID: 17914861 DOI: 10.1021/bp0701618] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Indocyanine green (ICG) is a photosensitive reagent with clinically relevant diagnostic and therapeutic applications. Recently, ICG has been investigated for its utility as an exogenous chromophore during laser-induced heating. However, ICG's effectiveness remains hindered by its molecular instability, rapid circulation kinetics, and nonspecific systemic distribution. To overcome these limitations, we have encapsulated ICG within dextran-coated mesocapsules (MCs). Our objective in this study was to explore the ability of MCs to induce thermal damage in response to laser irradiation. To simulate tumorous tissue targeted with MCs, cylindrical phantoms were prepared consisting of gelatin, intralipid emulsion, and various concentrations of MCs. The phantoms were embedded within fresh chicken breast tissue representing surrounding normal tissue. The tissue models were irradiated at lambda = 808 nm for 10 min at constant power (P = 4.2 W). Five hypodermic thermocouples were used to record the temperature at various depths below the tissue surface and transverse distances from the laser beam central axis during irradiation. Temperature profiles were processed to remove the baseline temperature and influence of light absorption by the thermocouple and subsequently used to calculate a damage index based on the Arrhenius damage integral. Tissue models containing MCs experienced a maximum temperature change of 18.5 degrees C. Damage index calculations showed that the heat generation from MCs at these parameters is sufficient to induce thermal damage, while no damage was predicted in the absence of MCs. ICG maintains its heat-generating capabilities in response to NIR laser irradiation when encapsulated within MCs. Such encapsulation provides a potentially useful methodology for laser-induced therapeutic strategies.
Collapse
|
|
18 |
45 |
16
|
Sarshar M, Wong WT, Anvari B. Comparative study of methods to calibrate the stiffness of a single-beam gradient-force optical tweezers over various laser trapping powers. JOURNAL OF BIOMEDICAL OPTICS 2014; 19:115001. [PMID: 25375348 PMCID: PMC4221290 DOI: 10.1117/1.jbo.19.11.115001] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2014] [Revised: 09/16/2014] [Accepted: 09/29/2014] [Indexed: 05/13/2023]
Abstract
Optical tweezers have become an important instrument in force measurements associated with various physical, biological, and biophysical phenomena. Quantitative use of optical tweezers relies on accurate calibration of the stiffness of the optical trap. Using the same optical tweezers platform operating at 1064 nm and beads with two different diameters, we present a comparative study of viscous drag force, equipartition theorem, Boltzmann statistics, and power spectral density (PSD) as methods in calibrating the stiffness of a single beam gradient force optical trap at trapping laser powers in the range of 0.05 to 1.38 W at the focal plane. The equipartition theorem and Boltzmann statistic methods demonstrate a linear stiffness with trapping laser powers up to 355 mW, when used in conjunction with video position sensing means. The PSD of a trapped particle's Brownian motion or measurements of the particle displacement against known viscous drag forces can be reliably used for stiffness calibration of an optical trap over a greater range of trapping laser powers. Viscous drag stiffness calibration method produces results relevant to applications where trapped particle undergoes large displacements, and at a given position sensing resolution, can be used for stiffness calibration at higher trapping laser powers than the PSD method.
Collapse
|
Comparative Study |
11 |
41 |
17
|
Bahmani B, Guerrero Y, Bacon D, Kundra V, Vullev VI, Anvari B. Functionalized polymeric nanoparticles loaded with indocyanine green as theranostic materials for targeted molecular near infrared fluorescence imaging and photothermal destruction of ovarian cancer cells. Lasers Surg Med 2014; 46:582-92. [DOI: 10.1002/lsm.22269] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/26/2014] [Indexed: 01/15/2023]
|
|
11 |
41 |
18
|
Chang CJ, Anvari B, Nelson JS. Cryogen spray cooling for spatially selective photocoagulation of hemangiomas: a new methodology with preliminary clinical reports. Plast Reconstr Surg 1998; 102:459-63. [PMID: 9703086 DOI: 10.1097/00006534-199808000-00029] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
Spatially selective photocoagulation of subsurface-targeted blood vessels by repetitive application of a short cryogen spurt during continuous Nd:YAG laser irradiation has been demonstrated in two human cases. This procedure may be effective for the treatment of thick hemangiomas that require photocoagulation of subsurface blood vessels while protecting the epidermis.
Collapse
|
Case Reports |
27 |
40 |
19
|
Tunnell JW, Torres JH, Anvari B. Methodology for estimation of time-dependent surface heat flux due to cryogen spray cooling. Ann Biomed Eng 2002; 30:19-33. [PMID: 11874138 DOI: 10.1114/1.1432691] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Cryogen spray cooling (CSC) is an effective technique to protect the epidermis during cutaneous laser therapies. Spraying a cryogen onto the skin surface creates a time-varying heat flux, effectively cooling the skin during and following the cryogen spurt. In previous studies mathematical models were developed to predict the human skin temperature profiles during the cryogen spraying time. However, no studies have accounted for the additional cooling due to residual cryogen left on the skin surface following the spurt termination. We formulate and solve an inverse heat conduction (IHC) problem to predict the time-varying surface heat flux both during and following a cryogen spurt. The IHC formulation uses measured temperature profiles from within a medium to estimate the surface heat flux. We implement a one-dimensional sequential function specification method (SFSM) to estimate the surface heat flux from internal temperatures measured within an in vitro model in response to a cryogen spurt. Solution accuracy and experimental errors are examined using simulated temperature data. Heat flux following spurt termination appears substantial; however, it is less than that during the spraying time. The estimated time-varying heat flux can subsequently be used in forward heat conduction models to estimate temperature profiles in skin during and following a cryogen spurt and predict appropriate timing for onset of the laser pulse.
Collapse
|
|
23 |
40 |
20
|
Jung B, Rao ALN, Anvari B. Optical nano-constructs composed of genome-depleted brome mosaic virus doped with a near infrared chromophore for potential biomedical applications. ACS NANO 2011; 5:1243-52. [PMID: 21210643 DOI: 10.1021/nn1028696] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
We have engineered an optical nanoconstruct composed of genome-depleted brome mosaic virus doped with indocyanine green (ICG), an FDA-approved near-infrared (NIR) chromophore. Constructs are highly monodispersed with standard deviation of ±3.8 nm from a mean diameter of 24.3 nm. They are physically stable and exhibit a high degree of optical stability at physiological temperature (37 °C). Using human bronchial epithelial cells, we demonstrate the effectiveness of the constructs for intracellular optical imaging in vitro, with greater than 90% cell viability after 3 h of incubation. These constructs may serve as a potentially nontoxic and multifunctional nanoplatform for site-specific deep-tissue optical imaging, and therapy of disease.
Collapse
|
|
14 |
40 |
21
|
Anvari B, Rastegar S, Motamedi M. Modeling of intraluminal heating of biological tissue: implications for treatment of benign prostatic hyperplasia. IEEE Trans Biomed Eng 1994; 41:854-64. [PMID: 7525453 DOI: 10.1109/10.312093] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
A computer model for predicting the thermal response of a biological tissue to different intraluminal heating modalities is presented. A practical application of the model is to calculate the temperature distributions during thermal coagulation of prostate by contact heating and radiative heating. The model uses a two-dimensional axisymmetric diffusion approximation method to calculate the light distribution during radiative heating. The traditional Pennes' bio-heat equation is used to calculate the temperatures in the presence of blood flow. An implicit finite difference scheme with nonuniform grid spacings is used to solve the diffusion equation for light distribution and the bio-heat equation. Model results indicate that the radiative heating of prostate by Nd:YAG (1064 mm) and diode (810 mm) lasers can be a more effective and efficient means of coagulating a large volume of prostate, as compared to contact heating of the tissue. Blood perfusion is shown to provide a considerable heat sink as the laser exposure time is increased. Surface cooling by irrigation during the laser irradiation of tissue is shown to be an effective method for delaying tissue explosion and obtaining a large volume of coagulated tissue. The model also shows that the volume of the coagulated tissue is appreciably altered by a change in the rate of energy deposition.
Collapse
|
|
31 |
39 |
22
|
Arya M, López JA, Romo GM, Cruz MA, Kasirer-Friede A, Shattil SJ, Anvari B. Glycoprotein Ib-IX-mediated activation of integrin alpha(IIb)beta(3): effects of receptor clustering and von Willebrand factor adhesion. J Thromb Haemost 2003; 1:1150-7. [PMID: 12871313 DOI: 10.1046/j.1538-7836.2003.00295.x] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
The interaction between the platelet glycoprotein (GP) Ib-IX complex and von Willebrand factor (VWF) initiates both hemostasis and pathological thrombosis. This interaction is not only the first adhesive event of platelets at sites of vessel injury, but also facilitates fibrinogen binding to alpha(IIb)beta(3), which subsequently results in platelet aggregation. Since it has been suggested that GP Ib-IX clustering may promote platelet activation, we investigated the effect of such clustering on both VWF-GP Ib-IX and fibrinogen-alpha(IIb)beta(3) bonds using optical tweezers. In our system, fusion of tandem repeats of FK506-binding protein (FKBP) to the cytoplasmic tail of the GP IX subunit of the GP Ib-IX complex allowed subsequent receptor clustering within the plasma membrane by the bivalent, cell-permeant small molecule ligand AP20187. We measured binding forces between polystyrene beads coated with either plasma-derived VWF or the VWF A1 domain and GP Ib-IX(FKBP)2, and those between fibrinogen-coated beads and alpha(IIb)beta(3) expressed on Chinese hamster ovary cells. The minimal detachment force between GP Ib-IX(FKBP)(2) and A1 or plasma-derived VWF doubled after AP20187 was added. The binding force between immobilized fibrinogen and alpha(IIb)beta(3) was not changed by the clustering agent; however, the strength of single fibrinogen-alpha(IIb)beta(3) bonds increased significantly after ligation of GP Ib-IX(FKBP)(2) by A1. These results demonstrate that GP Ib-IX clustering increases the overall strength of its interaction with VWF. Furthermore, signals from GP Ib-IX can activate alpha(IIb)beta(3), thereby increasing the strength of its interaction with fibrinogen.
Collapse
|
|
22 |
38 |
23
|
Tunnell JW, Chang DW, Johnston C, Torres JH, Patrick CW, Miller MJ, Thomsen SL, Anvari B. Effects of cryogen spray cooling and high radiant exposures on selective vascular injury during laser irradiation of human skin. ARCHIVES OF DERMATOLOGY 2003; 139:743-50. [PMID: 12810505 DOI: 10.1001/archderm.139.6.743] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
BACKGROUND Increasing radiant exposure offers a means to increase treatment efficacy during laser-mediated treatment of vascular lesions, such as port-wine stains; however, excessive radiant exposure decreases selective vascular injury due to increased heat generation within the epidermis and collateral damage to perivascular collagen. OBJECTIVE To determine if cryogen spray cooling could be used to maintain selective vascular injury (ie, prevent epidermal and perivascular collagen damage) when using high radiant exposures (16-30 J/cm2). DESIGN Observational study. SETTING Academic hospital and research laboratory. PATIENTS Twenty women with normal abdominal skin (skin phototypes I-VI). INTERVENTIONS Skin was irradiated with a pulsed dye laser (wavelength = 585 nm; pulse duration = 1.5 milliseconds; 5-mm-diameter spot) using various radiant exposures (8-30 J/cm2) without and with cryogen spray cooling (50- to 300-millisecond cryogen spurts). MAIN OUTCOME MEASURE Hematoxylin-eosin-stained histologic sections from each irradiated site were examined for the degree of epidermal damage, maximum depth of red blood cell coagulation, and percentage of vessels containing perivascular collagen coagulation. RESULTS Long cryogen spurt durations (>200 milliseconds) protected the epidermis in light-skinned individuals (skin phototypes I-IV) at the highest radiant exposure (30 J/cm2); however, epidermal protection could not be achieved in dark-skinned individuals (skin phototypes V-VI) even at the lowest radiant exposure (8 J/cm2). The red blood cell coagulation depth increased with increasing radiant exposure (to >2.5 mm for skin phototypes I-IV and to approximately 1.2 mm for skin phototypes V-VI). In addition, long cryogen spurt durations (>200 milliseconds) prevented perivascular collagen coagulation in all skin types. CONCLUSIONS Cryogen spurt durations much longer than those currently used in therapy (>200 milliseconds) may be clinically useful for protecting the epidermis and perivascular tissues when using high radiant exposures during cutaneous laser therapies. Additional studies are necessary to prove clinical safety of these protocols.
Collapse
|
Evaluation Study |
22 |
37 |
24
|
Arya M, Kolomeisky AB, Romo GM, Cruz MA, López JA, Anvari B. Dynamic force spectroscopy of glycoprotein Ib-IX and von Willebrand factor. Biophys J 2005; 88:4391-401. [PMID: 15764659 PMCID: PMC1305666 DOI: 10.1529/biophysj.104.046318] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
The first stage in hemostasis is the binding of the platelet membrane receptor glycoprotein (GP) Ib-IX complex to the A1 domain of von Willebrand factor in the subendothelium. A bleeding disorder associated with this interaction is platelet-type von Willebrand disease, which results from gain-of-function (GOF) mutations in amino acid residues 233 or 239 of the GP Ibalpha subunit of GP Ib-IX. Using optical tweezers and a quadrant photodetector, we investigated the binding of A1 to GOF and loss-of-function mutants of GP Ibalpha with mutations in the region containing the two known naturally occurring mutations. By dynamically measuring unbinding force profiles at loading rates ranging from 200-20,000 pN/s, we found that the bond strengths between A1 and GP Ibalpha GOF mutants (233, 235, 237, and 239) were significantly greater than the A1/wild-type GP Ib-IX bond at all loading rates examined (p < 0.05). In addition, mutants 231 and 232 exhibited significantly lower bond strengths with A1 than the wild-type receptors (p < 0.05). We computed unloaded dissociation rate constant (k(off)(0)) values for interactions involving mutant and wild-type GP Ib-IX receptors with A1 and found the A1/wild-type GP Ib-IX k(off)(0) value of 5.47 +/- 0.25 s(-1) to be significantly greater than the GOF k(off)(0) values and significantly less than the loss-of-function k(off)(0) values. Our data illustrate the importance of the bond kinetics associated with the VWF/GP Ib-IX interaction in hemostasis and also demonstrate the drastic changes in binding that can occur when only a single amino acid of GP Ibalpha is altered.
Collapse
|
Journal Article |
20 |
36 |
25
|
Upadhyayula S, Nuñez V, Espinoza EM, Larsen JM, Bao D, Shi D, Mac JT, Anvari B, Vullev VI. Photoinduced dynamics of a cyanine dye: parallel pathways of non-radiative deactivation involving multiple excited-state twisted transients. Chem Sci 2015; 6:2237-2251. [PMID: 29449923 PMCID: PMC5701728 DOI: 10.1039/c4sc02881c] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2014] [Accepted: 02/09/2015] [Indexed: 12/11/2022] Open
Abstract
Cyanine dyes are broadly used for fluorescence imaging and other photonic applications. 3,3'-Diethylthiacyanine (THIA) is a cyanine dye composed of two identical aromatic heterocyclic moieties linked with a single methine, -CH[double bond, length as m-dash]. The torsional degrees of freedom around the methine bonds provide routes for non-radiative decay, responsible for the inherently low fluorescence quantum yields. Using transient absorption spectroscopy, we determined that upon photoexcitation, the excited state relaxes along two parallel pathways producing three excited-state transients that undergo internal conversion to the ground state. The media viscosity impedes the molecular modes of ring rotation and preferentially affects one of the pathways of non-radiative decay, exerting a dominant effect on the emission properties of THIA. Concurrently, the polarity affects the energy of the transients involved in the decay pathways and further modulates the kinetics of non-radiative deactivation.
Collapse
|
research-article |
10 |
34 |