1
|
Histological evaluation of osseointegration between conventional and novel bone-level tapered implants in healed bone-A preclinical study. J Periodontal Res 2024. [PMID: 38764144 DOI: 10.1111/jre.13285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Revised: 04/10/2024] [Accepted: 04/24/2024] [Indexed: 05/21/2024]
Abstract
AIMS To histologically compare osseointegration and crestal bone healing between newly introduced tapered, self-cutting bone-level test implants and tapered bone-level control implants in sites with fully healed sites. METHODS Sixty-six implants (33 test, 33 control) were placed 1 mm subcrestally in a minipig model and underwent qualitative histologic and quantitative histometric analyses after 3, 6 and 12 weeks of submerged healing. The primary and secondary outcomes were the bone-to-implant contact (BIC) and first bone-to-implant contact (fBIC). Outcomes between the test and control implants were statistically compared. RESULTS The BIC values of the test implants were comparable and non-inferior over the time points studied, except for the 12 weeks time point which showed statistically significantly higher BIC values of the test (88.07 ± 5.35%) compared to the control implants (80.88 ± 7.51%) (p = .010). Similarly comparable and non-inferior were the fBIC values, except for the 6-week outcome, which showed statistically higher values for the test (-546.5 ± 450.80 μm) compared to the control implants (-75.7 ± 100.59 μm). fBIC results for the test implants were qualitatively more stable and consistent between test time points. CONCLUSION Novel self-cutting bone-level test implants demonstrated superior osseointegration and similar bone levels compared to conventional bone-level implants after a healing period of 12 weeks in healed ridges.
Collapse
|
2
|
Determining primary stability for adhesively stabilized dental implants. Clin Oral Investig 2023:10.1007/s00784-023-04990-8. [PMID: 37269339 DOI: 10.1007/s00784-023-04990-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Accepted: 03/28/2023] [Indexed: 06/05/2023]
Abstract
OBJECTIVES To examine factors influencing the primary stability of dental implants when stabilized in over-sized osteotomies using a calcium phosphate-based adhesive cement was the objective. METHODS Using implant removal torque measurements as a surrogate for primary stability, we examined the influence of implant design features (diameter, surface area, and thread design), along with cement gap size and curing time, on the resulting primary implant stability. RESULTS Removal torque values scaled with implant surface area and increasing implant diameters. Cement gap size did not alter the median removal torque values; however, larger gaps were associated with an increased spread of the measured values. Among the removal torque values measured, all were found to be above 32 Ncm which is an insertion torque threshold value commonly recommended for immediate loading protocols. CONCLUSION The adhesive cement show potential for offering primary implant stability for different dental implant designs. In this study, the primary parameters influencing the measured removal torque values were the implant surface area and diameter. As the liquid cement prevents the use of insertion torque, considering the relationship between insertion and removal torque, removal torque can be considered a reliable surrogate for primary implant stability for bench and pre-clinical settings. CLINICAL RELEVANCE At present, the primary stability of dental implants is linked to the quality of the host bone, the drill protocol, and the specific implant design. The adhesive cement might find applications in future clinical settings for enhancing primary stability of implants under circumstances where this cannot be achieved conventionally.
Collapse
|
3
|
Immediate Loading of a Fully Tapered Implant with Deep Apical Threads Placed in Healed Alveolar Ridges vs. Immediate Extraction Sockets. Clin Oral Implants Res 2022; 33:501-510. [PMID: 35213758 DOI: 10.1111/clr.13910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Revised: 01/09/2022] [Accepted: 02/09/2022] [Indexed: 11/30/2022]
Abstract
OBJECTIVES Immediate implant placement and loading is a practice that continues to gain traction in implant dentistry because it reduces treatment time and improves satisfaction. Novel implant designs that facilitate increased primary stability, while not compromising osseointegration and long-term survival are important to offer immediate solutions for missing teeth. Here, we hypothesize that fully tapered implants can obtain successful osseointegration with high survival rates after immediate loading in fresh extraction sockets and healed sites. MATERIALS AND METHODS 13 swine with 73 implants were evaluated. Fully tapered or apically tapered implants were placed in extraction sockets and healed sites. Insertion torque and resonance frequency analysis were determined at placement and euthanasia. Animals were evaluated at: placement, and 1-week and 12-weeks after placement. Bone to Implant Contact (BIC), Bone Area / Total Area (BA/TA), and first BIC (fBIC) analyses was conducted. RESULTS The fully tapered implant achieved similar primary stability with lower insertion torque at placement (Fig. 2). Apically and fully tapered implants had comparable BIC (50.1% vs 59.4%) and ISQ (82.5 vs 80.3) values by 12 weeks in healed sites. In extraction sockets, BIC and ISQ for the apically tapered implant was 35.8% and 73.2 and 37.8% and 79.2 for the fully tapered implants, respectively (Fig. 2, 5). CONCLUSIONS In this short-term study, immediately loaded fully tapered implants obtained high survival with similar osseointegration ability as apically tapered implants when placed in healed sites and fresh extraction sockets. Fully tapered implants show promise for use in immediate loading and immediate placement.
Collapse
|
4
|
Peri-implant bone preservation of a novel, self-cutting, and fully tapered implant in the healed crestal ridge of minipigs: submerged vs. transgingival healing. Clin Oral Investig 2021; 25:6821-6832. [PMID: 33950374 PMCID: PMC8602133 DOI: 10.1007/s00784-021-03970-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2020] [Accepted: 04/26/2021] [Indexed: 12/03/2022]
Abstract
OBJECTIVES The aim of this study was to assess the influence of transgingival compared with submerged healing on peri-implant bone maintenance around a novel, fully tapered implant in a healed crestal ridge in minipigs. MATERIALS AND METHODS In each of 12 minipigs, two implants (Straumann® BLX, Roxolid® SLActive®, Ø 3.75 × 8 mm) were placed. Implants were either left for submerged or for transgingival healing for 12 weeks. Measurements performed were bone-to-implant contact (BIC), first bone-to-implant contact (fBIC), bone area to total area (BATA), perpendicular bone crest to implant shoulder (pCIS), bone height change from placement, and bone overgrowth (for submerged implants). RESULTS No significant differences were found between transgingival and submerged healing in any of the measured parameters, except for BATA on the buccal aspect in which significantly more bone formation was found for the transgingival healing group. For both groups, there was a gain in crestal bone height during the 12-week healing period. CONCLUSIONS Loaded compared with unloaded implants displayed comparable levels of osseointegration and equivalent marginal bone levels. This qualifies the implant placement protocol with respect to the osteotomy dimensions and subcrestal placement protocol for immediate loading. CLINICAL RELEVANCE The here presented results related to osseointegration and crestal bone maintenance after submerged or transgingival healing have demonstrated a high level of consistency in the used in vivo translational model. The obtained results support the translation of the novel implant type in conjunction with the developed surgical workflow and placement protocol into further clinical investigation and use.
Collapse
|
5
|
Comparative barrier membrane degradation over time: Pericardium versus dermal membranes. Clin Exp Dent Res 2021; 7:711-718. [PMID: 33949796 PMCID: PMC8543466 DOI: 10.1002/cre2.414] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Revised: 02/01/2021] [Accepted: 02/03/2021] [Indexed: 11/25/2022] Open
Abstract
Objective The effectiveness of GBR procedures for the reconstruction of periodontal defects has been well documented. The objective of this investigation was to evaluate the degradation kinetics and biocompatibility of two resorbable collagen membranes in conjunction with a bovine xenograft material. Materials and Methods Lower premolars and first molars were extracted from 18 male Yucatan minipigs. After 4 months of healing, standardized semi‐saddle defects were created (12 mm × 8 mm × 8 mm [l˙̇ × W˙ × d]), with 10 mm between adjacent defects. The defects were filled with a bovine xenograft and covered with a either the bilayer collagen membrane (control) or the porcine pericardium‐derived collagen membrane (test). Histological analysis was performed after 4, 8, and 12 weeks of healing and the amount of residual membrane evaluated. Non‐inferiority was calculated using the Brunner‐Langer mixed regression model. Results Histological analysis indicated the presence of residual membrane in both groups at all time points, with significant degradation noted in both groups at 12 weeks compared to 4 weeks (p = .017). No significant difference in ranked residual membrane scores between the control and test membranes was detected at any time point. Conclusions The pericardium‐derived membrane was shown to be statistically non‐inferior to the control membrane with respect to resorption kinetics and barrier function when utilized for guided bone regeneration in semi‐saddle defects in minipigs. Further evaluation is necessary in the clinical setting.
Collapse
|
6
|
A novel fully tapered, self-cutting tissue-level implant: non-inferiority study in minipigs. Clin Oral Investig 2021; 25:6127-6137. [PMID: 33861379 PMCID: PMC8531107 DOI: 10.1007/s00784-021-03912-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Accepted: 03/23/2021] [Indexed: 11/29/2022]
Abstract
Objectives To assess the osseointegration and crestal bone level maintenance of a novel fully tapered self-cutting tissue-level implant for immediate placement (test) compared to a clinically established tissue-level implant (control) in moderate bone quality. Materials and methods Test and control implants were compared in 3 groups, i.e., small-, medium-, and large-diameter implants in an edentulous mandibular minipig model with moderate bone quality after 12 weeks of healing. Histometrically derived bone-to-implant contact (BIC) and first bone-to-implant contact (fBIC) were subjected to statistical non-inferiority testing. Maximum insertion torque values in artificial bone were assessed for comparison. Results BIC values for the tests and control implants for all 3 diameters were comparable and non-inferior: small diameter (61.30 ± 10.63% vs. 54.46 ± 18.31%) (p=0.99), medium diameter (60.91 ± 14.42 vs. 54.68 ± 9.16) (p=0.55), and large diameter (45.60 ± 14.67 vs. 52.52 ± 14.76) (p=0.31). fBIC values for test implants were higher and non-inferior compared to control implants in all three groups. Test implants further showed distinctly higher maximum insertion torque values compared to control implants. Conclusion The investigated novel tissue-level implant is able to achieve high levels of primary and secondary implant stability under simultaneous preservation of crestal bone levels. This qualifies the studied implant as an attractive candidate for immediate placement in bone of limited quality. Clinical relevance This pilot pre-clinical study investigated a novel tissue-level implant for immediate placement. With the aim of translating the studied prototype into clinical application pre-clinical models, procedures and controls have been chosen with the aim of reflecting its future clinical indication and use. Supplementary Information The online version contains supplementary material available at 10.1007/s00784-021-03912-w.
Collapse
|
7
|
Greater Osseointegration Potential with Nanostructured Surfaces on TiZr: Accelerated vs. Real-Time Ageing. MATERIALS 2021; 14:ma14071678. [PMID: 33805477 PMCID: PMC8036800 DOI: 10.3390/ma14071678] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Revised: 03/16/2021] [Accepted: 03/22/2021] [Indexed: 11/16/2022]
Abstract
Surface chemistry and nanotopography of dental implants can have a substantial impact on osseointegration. The aim of this investigation was to evaluate the effects of surface chemistry and nanotopography on the osseointegration of titanium-zirconium (TiZr; Roxolid®) discs, using a biomechanical pull-out model in rabbits. Two discs each were placed in both the right and left tibiae of 16 rabbits. Five groups of sandblasted acid etched (SLA) discs were tested: (1) hydrophobic without nanostructures (dry/micro) (n = 13); (2) hydrophobic with nanostructures, accelerated aged (dry/nano/AA) (n = 12); (3) hydrophilic without nanostructures (wet/micro) (n = 13); (4) hydrophilic with nanostructures, accelerated aged (wet/nano/AA; SLActive®) (n = 13); (5) hydrophilic with nanostructures, real-time aged (wet/nano/RTA). The animals were sacrificed after four weeks and the biomechanical pull-out force required to remove the discs was evaluated. Adjusted mean pull-out force was greatest for group wet/nano/RTA (64.5 ± 17.7 N) and lowest for group dry/micro (33.8 ± 10.7 N). Multivariate mixed model analysis showed that the pull-out force was significantly greater for all other disc types compared to the dry/micro group. Surface chemistry and topography both had a significant effect on pull-out force (p < 0.0001 for both), but the effect of the interaction between chemistry and topography was not significant (p = 0.1056). The introduction of nanostructures on the TiZr surface significantly increases osseointegration. The introduction of hydrophilicity to the TiZr implant surface significantly increases the capacity for osseointegration, irrespective of the presence or absence of nanotopography.
Collapse
|
8
|
Thermal exposure of implant osteotomies and its impact on osseointegration-A preclinical in vivo study. Clin Oral Implants Res 2021; 32:672-683. [PMID: 33629437 DOI: 10.1111/clr.13729] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Revised: 02/10/2021] [Accepted: 02/17/2021] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Thermal and mechanical stresses during osteotomy preparation can impair implant osseointegration. This study investigated implant osseointegration following the measurement of temperature exposure during osteotomy drilling, varying drill design, sequence, and drill wear. MATERIALS AND METHODS 36 tapered implants were placed in a mandibular minipig model after guided drilling of implant osteotomies using 4 different groups: (1) control drills with a conservative, sequential drilling sequence, (2) control drills using a shortened drill sequence (PF), (3) novel test drill displaying an optimized drill design and surface treatment, PF, and (4) aged test drill, PF. Intraosseous temperatures during drilling were measured using a temperature probe. BIC, fBIC, and tissue reactions were histomorphometrically derived after 2 and 8 weeks of healing. RESULTS Compared to control drills (1) or (2), test drills (3) resulted in significantly lower maximum temperatures ((35.4 (CI 30.2-40.5)°C vs. (46.5 (CI 41.0-52.0)°C, p = .0021)) and shorter drill times ((4.5 (CI 1.6-7.3)sec vs. 10.3 (7.3-13.4)sec). Lower osteotomy temperature values and shorter drill times corroborated with significantly higher BIC after 2 and 8 weeks healing for the test (3) compared to control groups (2) (2 weeks: (44.9 (CI 34.1-55. 7)% vs. (31.3 (CI 20.5-42.2)%, p = <.0001 and 8 weeks: (73.7 ( CI 64.2-83.2)% vs. (66.2 (CI 57.0-75.4)%, p = <.0455). CONCLUSION The improved osseointegration of implants placed after osteotomy preparation with novel test drills using a shortened drill sequence compared to standard drills and conventional drill protocols might be attributed to more favorable thermal profiles and less mechanical stress exerted on the bone surrounding the implant osteotomy.
Collapse
|
9
|
A Novel Xenograft Bone Substitute Supports Stable Bone Formation in Circumferential Defects Around Dental Implants in Minipigs. Int J Oral Maxillofac Implants 2020; 35:1122-1131. [PMID: 33270052 DOI: 10.11607/jomi.8265] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
PURPOSE The aim of this study was to evaluate and compare bone growth and implant integration in circumferential defects with two commercially available bone substitutes (demineralized bovine bone mineral [DBBM]). MATERIALS AND METHODS Circumferential defects were created in the mandibles of minipigs (n = 10), and Bone Level Tapered implants (Straumann Roxolid with SLActive surface) were placed. The defects (4-mm-deep circumferential defect, 2 mm around each implant) were augmented with either sintered bovine bone mineral (test, cerabone) or natural bovine bone mineral (control, Bio-Oss). Bone formation and tissue composition in augmented sites were histomorphometrically assessed after 8 and 12 weeks of healing time (n = 5 each), respectively, in terms of the percentage of area of newly formed bone to total area, bone-to-implant contact (BIC), and crestal bone height relative to the implant shoulder (first bone-to-implant contact [fBIC]). RESULTS Bone formation in all defect sites was adequate and equivalent for both groups at individual healing time points. The amount of residual graft material was comparable in both groups after 8 and 12 weeks, with no significant resorption in either group. The mean newly formed bone area in the test group amounted to 46.7% ± 5.1% and 48.7% ± 4.0% after 8 and 12 weeks vs 47.0% ± 4.8% and 47.8% ± 7.3% in the control group, respectively. BIC and fBIC as individually assessed for the lingual and buccal aspects were comparable at both healing time points without any statistically significant differences between the groups. A slightly greater variability of fBIC was observed within the test group. CONCLUSION The results of this study indicate that test and control materials both represent viable bovine bone graft material that equivalently support the formation of new and stable bone volume specifically when used for simultaneous augmentation around implants.
Collapse
|
10
|
Evaluation of air polishing with a sterile powder and mechanical debridement during regenerative surgical periimplantitis treatment: a study in dogs. Clin Oral Investig 2020; 25:2609-2618. [PMID: 32914269 PMCID: PMC8060171 DOI: 10.1007/s00784-020-03572-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2020] [Accepted: 09/03/2020] [Indexed: 11/28/2022]
Abstract
Objectives To evaluate the effectiveness of mechanical debridement and/or air polishing on the healing of ligature-induced buccal periimplantitis dehiscence defects in dogs. Material and methods Forty-eight implants were placed in the mandibles of twelve beagle dogs, and periimplantitis was induced for 2 months using ligatures. The resulting buccal dehiscence-type defects were surgically cleaned and augmented (xenogenic filler and resorbable membrane) according to one of the following treatments: (1) Cleaning with carbon curette (debridement - D) and guided bone regeneration (GBR/G): DG, (2) air polishing cleaning (A) and GBR: AG, (3) a combination of D/A/G: DAG, and (4) D/A without GBR: DA. After 2 months, histomorphometric and inflammatory evaluations were conducted. Results The median bone gain after therapy ranged between 1.2 mm (DG) and 2.7 mm (AG). Relative bone gain was between 39% (DG) and 59% (AG). The lowest inflammation scores were obtained in DA without GBR (5.84), whereas significantly higher values between 8.2 and 9.4 were found in the groups with augmentation. At lingual sites without defects, scores ranged from 4.1 to 5.9. According to ISO, differences above 2.9 were considered representative for irritative properties. Conclusions All treatments resulted in partial regeneration of the defects. No treatment group showed a significantly (p < 0.05) better outcome. However, pretreatment with air polishing showed a tendency for less inflammation. Noteworthy, inflammation assessment showed an overall irritative potential after GBR in the evaluated early healing phase. Clinical relevance Periimplantitis treatment still represents a big issue in daily practice and requires additional preclinical research in order to improve treatment concepts.
Collapse
|
11
|
Osseointegration of a novel injection molded 2-piece ceramic dental implant: a study in minipigs. Clin Oral Investig 2020; 25:603-615. [PMID: 32914271 DOI: 10.1007/s00784-020-03513-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 08/06/2020] [Indexed: 10/23/2022]
Abstract
OBJECTIVES This study compared the osseointegrative potential of a novel injection molded zirconia dental implant (Neodent Zi ceramic implant, test) and a commercially available titanium implant (Neodent Alvim implant, control) in terms of histomorphometrically derived bone-to-implant contact (BIC), first bone-to-implant contact (fBIC), and the ratio of bone area to total area (BATA) around the implant. MATERIALS AND METHODS A total of 36 implants, 18 per individual test device, were implanted in a split-mouth arrangement in either side of the edentulous and fully healed mandible of 6 minipigs. Histomorphometric analysis of BIC, fBIC, and BATA were performed 8 weeks post implantation and subjected to statistical non-inferiority testing. Surface characteristics of both implant types were compared in terms of contact angle, surface topography, and elemental composition. RESULTS BIC, fBIC, and coronal BATA values of test and control implants were statistically comparable and non-inferior. BIC values of 77.8 ± 6.9% vs. 80.7 ± 6.9% (p = 0.095) were measured for the test and control groups. fBIC lingual values were - 238 ± 328 μm compared with - 414 ± 511 μm (p = 0.121) while buccal values were - 429 ± 648 μm and - 588 ± 550 μm (p = 0.230) for the test and control devices, respectively. BATA in the apical segment was significantly higher in the test group compared with the control group (67.2 ± 11.8% vs. 59.1 ± 11.4%) (p = 0.0103). Surface topographies of both implant types were comparable. Surface chemical analysis indicated the presence of carbonaceous adsorbates which correlated with a comparable and predominantly hydrophobic character of the implants. CONCLUSION The results demonstrate that the investigated zirconia implants, when compared with a commercially available titanium implant, show equivalent and non-inferior bone integration, bone formation, and alveolar bone level maintenance. This qualifies the investigated zirconia implant as a potential candidate for clinical development. CLINICAL RELEVANCE This study investigated the osseointegration of a novel zirconia 2-piece dental implant prototype intended for clinical development. With the aim of translating this prototype into clinical development preclinical models, procedures and materials within this study have been selected as close to clinical practice and human physiological conditions as possible.
Collapse
|
12
|
Surface modification of ultrafine-grained titanium: Influence on mechanical properties, cytocompatibility, and osseointegration potential. Clin Oral Implants Res 2019; 30:99-110. [PMID: 30521101 DOI: 10.1111/clr.13396] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2017] [Revised: 11/19/2018] [Accepted: 11/21/2018] [Indexed: 01/08/2023]
Abstract
OBJECTIVE The main objective of this study was to demonstrate that dental implants made from ultrafine-grain titanium (UFG-Ti) can be created that replicate state of the art surfaces of standard coarse-grain titanium (Ti), showing excellent cytocompatibility and osseointegration potential while also providing improved mechanical properties. MATERIAL AND METHODS UFG-Ti was prepared by continuous equal channel angular processing (ECAP), and surfaces were treated by sandblasting and acid etching. Mechanical properties (tensile and fatigue strength), wettability, and roughness parameters were evaluated. Human trabecular bone-derived osteoblast precursor cells (HBCs) were cultured on all samples to examine cytocompatibility and mineralization after 4 and 28 days, respectively. Biomechanical pull-out measurements were performed in a rabbit in vivo model 4 weeks after implantation. RESULTS Both yield and tensile strength as well as fatigue endurance were higher for UFG-Ti compared to Ti by 40%, 45%, and 34%, respectively. Fatigue endurance was slightly reduced following surface treatment. Existing surface treatment protocols could be applied to UFG-Ti and resulted in similar roughness and wettability as for standard Ti. Cell attachment and spreading were comparable on all samples, but mineralization was higher for the surfaces with hydrophilic treatment with no significant difference between UFG-Ti and Ti. Pull-out tests revealed that osseointegration of surface-treated UFG-Ti was found to be similar to that of surface-treated Ti. CONCLUSION It could be demonstrated that existing surface treatments for Ti can be translated to UFG-Ti and, furthermore, that dental implants made from surface-treated UFG-Ti exhibit superior mechanical properties while maintaining cytocompatibility and osseointegration potential.
Collapse
|
13
|
Ascorbic Acid Attenuates Senescence of Human Osteoarthritic Osteoblasts. Int J Mol Sci 2017; 18:ijms18122517. [PMID: 29186811 PMCID: PMC5751120 DOI: 10.3390/ijms18122517] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2017] [Revised: 11/08/2017] [Accepted: 11/20/2017] [Indexed: 12/28/2022] Open
Abstract
The accumulation of senescent cells is implicated in the pathology of several age-related diseases. While the clearance of senescent cells has been suggested as a therapeutic target for patients with osteoarthritis (OA), cellular senescence of bone-resident osteoblasts (OB) remains poorly explored. Since oxidative stress is a well-known inducer of cellular senescence, we here investigated the effect of antioxidant supplementation on the isolation efficiency, expansion, differentiation potential, and transcriptomic profile of OB from osteoarthritic subchondral bone. Bone chips were harvested from sclerotic and non-sclerotic regions of the subchondral bone of human OA joints. The application of 0.1 mM ascorbic acid-2-phosphate (AA) significantly increased the number of outgrowing cells and their proliferation capacity. This enhanced proliferative capacity showed a negative correlation with the amount of senescent cells and was accompanied by decreased expression of reactive oxygen species (ROS) in cultured OB. Expanded cells continued to express differentiated OB markers independently of AA supplementation and demonstrated no changes in their capacity to osteogenically differentiate. Transcriptomic analyses revealed that apoptotic, cell cycle–proliferation, and catabolic pathways were the main pathways affected in the presence of AA during OB expansion. Supplementation with AA can thus help to expand subchondral bone OB in vitro while maintaining their special cellular characteristics. The clearance of such senescent OB could be envisioned as a potential therapeutic target for the treatment of OA.
Collapse
|
14
|
In vitro evaluation of an injectable biphasic calcium phosphate (BCP) carrier system combined with recombinant human bone morphogenetic protein (rhBMP)-9. Biomed Mater Eng 2017; 28:293-304. [PMID: 28527192 DOI: 10.3233/bme-171675] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Bone morphogenetic protein 9 (BMP9) has previously been characterized as the strongest osteoinductive growth factor among the BMP family. The aim of the present study was to evaluate the possibility of combining rhBMP9 with an injectable biphasic calcium phosphate (I-BCP, maxresorb inject®), since I-BCP is an easy to handle biomaterial with ideal properties for bone augmentation procedures. The adsorption potential of rhBMP9 as well as the cell behavior of bone stromal ST2 cells were investigated on cell viability, adhesion, proliferation and osteogenic differentiation for I-BCP combined with/without rhBMP9 in vitro. I-BCP demonstrated excellent adsorption/retention potential of rhBMP9 with a slow and steady release over a 10 day period by ELISA. Cell attachment at 8 hours and cell proliferation at 1, 3 and 5 days was decreased on I-BCP with/without rhBMP9 when compared to control tissue-culture plastic. While I-BCP had little influence on osteoblast differentiation, its combination with rhBMP9 significantly increased ALP activity at 7 days and mRNA levels of osteoblast differentiation markers including ALP and osteocalcin at 14 days. I-BCP served as an excellent carrier for rhBMP9 clearly demonstrating its osteoinductive potential. We therefore confirm the great potential of rhBMP9 to serve as a future regenerative growth factor for bone applications.
Collapse
|
15
|
Effect of Osteotomy Preparation on Osseointegration of Immediately Loaded, Tapered Dental Implants. Adv Dent Res 2017; 28:34-41. [PMID: 26927486 DOI: 10.1177/0022034515624446] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The aim of the present preclinical in vivo study was to evaluate whether a modified "drill-only" protocol, involving slight underpreparation of the implant site, may have an effect on aspects of osseointegration of a novel bone-level tapered implant, compared with the "standard drilling" protocol involving taping and profiling of the marginal aspect of the implant socket. In each side of the edentulated and completely healed mandible of 11 minipigs, 2 tapered implants (8 mm long × 4.1 mm Ø, BLT; Institut Straumann AG, Basel, Switzerland) were installed either with the drill-only or the standard drilling protocol. Significantly lower average insertion torque values were recorded for the standard drilling protocol group (52 ± 29 Ncm) compared with the drill-only group (70 ± 27 Ncm) (t test, P ≤ 0.05); no significant difference was observed between the 2 groups regarding implant stability, by means of resonance frequency analysis (75 ± 8 vs. 75 ± 6, respectively). Half of the implants were immediately loaded and the rest were submerged, providing observation times of 8 or 4 wk, respectively. Non-decalcified histological and histomorphometric analysis of the implants with surrounding tissues showed no significant differences between the 2 drilling protocols regarding the distance from the implant platform to the first coronal bone-to-implant contact (f-BIC), the total bone-to-implant contact (BIC) as a percentage of the total implant perimeter, and the bone density in an area extending 1 mm laterally from the implant (BATA) within 2 rectangular regions of interest (ROIs) 4 mm in height, representing the coronal (parallel-walled) and apical (tapered) aspect of the implant (ROI 1 and ROI 2, respectively) in non-submerged implants. In general, marginal peri-implant bone levels were at or slightly apical to the implant platform, and large amounts of bone-to-implant contact were observed. In contrast, immediately loaded implants placed with the drill-only protocol showed statistically significantly lower BIC values (66% ± 13.7%) compared with those installed with the standard drilling protocol (74.8% ± 11.2%) (P = 0.018). In addition, although marginal bone levels were in most of the immediately loaded implants at or slightly apical to the implant platform, some of the implants installed with the drill-only protocol showed marginal bone loss and crater formation. Thus, in this model system, even slight underpreparation of the implant socket appeared to compromise osseointegration of immediately loaded bone-level tapered implants.
Collapse
|
16
|
Absorbable collagen sponges loaded with recombinant bone morphogenetic protein 9 induces greater osteoblast differentiation when compared to bone morphogenetic protein 2. Clin Exp Dent Res 2017; 3:32-40. [PMID: 29744176 PMCID: PMC5839213 DOI: 10.1002/cre2.55] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2016] [Revised: 11/27/2016] [Accepted: 12/07/2016] [Indexed: 12/29/2022] Open
Abstract
The use of growth factors for the regeneration of soft and hard tissues has been utilized extensively in dental medicine over the past decade. Recently our group found that recombinant human bone morphogenetic protein 9 (rhBMP9) was more osteopromotive than recombinant human bone morphogenetic protein 2 (rhBMP2) when combined with a deprotenized bovine bone mineral bone grafting material. The aim of the present in vitro study was to evaluate the regenerative potential of an absorbable collagen sponge(ACS) specifically designed for extraction socket healing loaded with rhBMP9 when compared to rhBMP2. The adsorption and release kinetics of rhBMP2 and rhBMP9 were first investigated by enzyme-linked immunosorbent assay quantification. Then, the cellular effects of stromal cell line (ST2) preosteoblasts were investigated utilizing four groups including rhBMP2 and rhBMP9 at both low(10 ng/ml) and high(100 ng/ml) concentrations loaded onto ACS. Cellular attachment(8 hours) and proliferation(1, 3, and 5 days) as well as osteoblast differentiation were investigated by real-time polymerase chain reaction (PCR) at 3 and 14 days, alkaline phosphatase (ALP) activity at 7 days, and alizarin red staining at 14 days. ACS fully adsorbed both rhBMP2 and rhBMP9 that were slowly released up to 10 days. Although neither rhBMP2 nor rhBMP9 had any effects on cell attachment or proliferation, pronounced effects were observed on osteoblast differentiation. ALP activity was increased seven-fold with rhBMP2-high, whereas a marked 10-fold and 20-fold increase was observed with rhBMP9-low and high loaded to ACS, respectively. Furthermore, mRNA levels of collagen1, ALP, bone sialoprotein, and osteocalcin were all significantly higher for rhBMP9 when compared to control or rhBMP2 groups. Alizarin red staining further confirmed that rhBMP9-low and high demonstrated marked increases in mineralization potential when compared to rhBMP2-high. The results demonstrate the marked effect of rhBMP9 on osteoblast differentiation when combined with ACS in comparison to rhBMP2 at doses as much as 10 times lower. Further in vivo studies are necessary to investigate whether the regenerative potential is equally as potent.
Collapse
|
17
|
Osteoinductive potential of 4 commonly employed bone grafts. Clin Oral Investig 2016; 20:2259-2265. [PMID: 26814714 DOI: 10.1007/s00784-016-1724-4] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2015] [Accepted: 01/12/2016] [Indexed: 02/07/2023]
Abstract
OBJECTIVES Guided bone regeneration (GBR) aims to predictably restore missing bone that has been lost due to trauma, periodontal disease or a variety of systemic conditions. Critical to this procedure is the ability of a bone grafting material to predictably serve as a 3-dimensional scaffold capable of inducing cell and bone tissue in-growth at the material surface. Although all bone grafts are osteoconductive to bone-forming osteoblasts, only a small number of commercially available bone grafts with FDA approval are osteoinductive including demineralized freeze-dried bone allographs (DFDBA) and scaffolds containing bone morphogenetic proteins (BMPs). Recently, a class of synthetic bone grafts fabricated from biphasic calcium phosphate (BCP) sintered at a low temperature have been shown to form ectopic bone formation in non-skeletal sites without the use of growth factors. Therefore, the present study aimed to compare the osteoinductive potential of this group of synthetic BCP alloplasts with autografts, allografts and xenografts. MATERIALS AND METHODS In the present study, 4 types of bone grafting materials including autogenous bone harvested with a bone mill, DFDBA (LifeNet, USA), a xenograft derived from bovine bone mineral (NBM, BioOss, Geistlich, Switzerland) and a novel synthetic biphasic calcium phosphate (BCP, Straumman, Switzerland) were implanted into intramuscular pouches of 24 rats and analysed histologically for their ability to form ectopic bone formation around grafting particles. A semi-quantitative osteoinductive score was used to quantify the osteoinductive ability of each bone graft. RESULTS The results from the present study reveal that (1) autogenous bone resorbed rapidly in vivo, (2) the xenograft showed no potential to form ectopic bone formation and (3) both DFDBA and BCP were able to stimulate ectopic bone formation. CONCLUSION These studies demonstrate that these newly developed synthetic bone grafts have potential for inducing ectopic bone formation similar to DFDBA. Future clinical testing is necessary to reveal their bone-inducing properties in clinical scenarios including GBR procedures and in combination with implant dentistry. CLINICAL RELEVANCE Novel BCP scaffolds are able to induce ectopic bone formation without the use of osteoinductive growth factors such as BMP2 and thus demonstrate a large clinical possibility to further enhance bone formation for a variety of clinical procedures.
Collapse
|
18
|
Multicolor flow cytometry-based cellular phenotyping identifies osteoprogenitors and inflammatory cells in the osteoarthritic subchondral bone marrow compartment. Osteoarthritis Cartilage 2015; 23:1865-9. [PMID: 26521732 DOI: 10.1016/j.joca.2015.07.021] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2014] [Revised: 07/10/2015] [Accepted: 07/20/2015] [Indexed: 02/02/2023]
Abstract
PURPOSE The cellular component of subchondral bone is thought to be responsible for aberrant bone remodeling in osteoarthritis (OA). Direct phenotypical analysis of the cellular compartment is critical to better understand the OA disease process. This study provides proof-of-principle for flow cytometry-based phenotyping of isolated subchondral trabecular bone (STB) marrow cells without prior use of cell culture techniques. METHODS Tibial plateaus were obtained from OA patients undergoing total knee arthroplasty. Subchondral bone chips were digested with collagenase IA and single cell suspensions were directly phenotyped using flow cytometry. Cells were analyzed for the expression of alkaline phosphatase (ALP) as osteoblast/osteoprogenitor marker and monocyte/macrophage markers (CD14, CD68, HLA-DR, CD115). RESULTS MTT staining revealed abundant viable cells in the bone marrow compartment of STB prior to digestion, which were efficiently released by collagenase. Within the CD45-negative cell fraction, approximately 20% of the cells were positive for the early osteoblast/osteoprogenitor marker ALP. Within the CD45+ hematopoietic cell fraction, the majority of cells were of monocytic origin (>80%) displaying strong surface expression of CD14. Discreet macrophage populations (CD14+/HLA-DR+/CD68+) and putative osteoclast progenitors (CD45+/HLA-DR-/CD115+) were unequivocally identified. Osteoblast, macrophage and osteoclast progenitor presence in the subchondral bone unit (SBU) was confirmed by (immuno)histochemical staining for osteocalcin, CD68 and tartrate-resistant acid phosphatase, respectively. CONCLUSIONS Flow cytometric analysis is a valuable methodology to study the cellular compartment of STB marrow. This method provides a proof of principle that the whole resident cell population can be directly phenotypically characterized without the prior use of cell culture techniques.
Collapse
|
19
|
Pooled thrombin-activated platelet-rich plasma: a substitute for fetal bovine serum in the engineering of osteogenic/vasculogenic grafts. J Tissue Eng Regen Med 2015; 11:1542-1552. [DOI: 10.1002/term.2054] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2014] [Revised: 04/08/2015] [Accepted: 04/29/2015] [Indexed: 01/12/2023]
|
20
|
Bone-forming capacity of adult human nasal chondrocytes. J Cell Mol Med 2015; 19:1390-9. [PMID: 25689393 PMCID: PMC4459852 DOI: 10.1111/jcmm.12526] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2014] [Accepted: 11/27/2014] [Indexed: 12/26/2022] Open
Abstract
Nasal chondrocytes (NC) derive from the same multipotent embryological segment that gives rise to the majority of the maxillofacial bone and have been reported to differentiate into osteoblast-like cells in vitro. In this study, we assessed the capacity of adult human NC, appropriately primed towards hypertrophic or osteoblastic differentiation, to form bone tissue in vivo. Hypertrophic induction of NC-based micromass pellets formed mineralized cartilaginous tissues rich in type X collagen, but upon implantation into subcutaneous pockets of nude mice remained avascular and reverted to stable hyaline-cartilage. In the same ectopic environment, NC embedded into ceramic scaffolds and primed with osteogenic medium only sporadically formed intramembranous bone tissue. A clonal study could not demonstrate that the low bone formation efficiency was related to a possibly small proportion of cells competent to become fully functional osteoblasts. We next tested whether the cues present in an orthotopic environment could induce a more efficient direct osteoblastic transformation of NC. Using a nude rat calvarial defect model, we demonstrated that (i) NC directly participated in frank bone formation and (ii) the efficiency of survival and bone formation by NC was significantly higher than that of reference osteogenic cells, namely bone marrow-derived mesenchymal stromal cells. This study provides a proof-of-principle that NC have the plasticity to convert into bone cells and thereby represent an easily available cell source to be further investigated for craniofacial bone regeneration.
Collapse
|
21
|
TGF-β-induced differentiation into myofibroblasts involves specific regulation of two MKL1 isoforms. Development 2014. [DOI: 10.1242/dev.109546] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
22
|
TGF-β-induced differentiation into myofibroblasts involves specific regulation of two MKL1 isoforms. J Cell Sci 2014; 127:1079-91. [PMID: 24424023 DOI: 10.1242/jcs.142075] [Citation(s) in RCA: 75] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Cellular transformation into myofibroblasts is a central physiological process enabling tissue repair. Its deregulation promotes fibrosis and carcinogenesis. TGF-β is the main inducer of the contractile gene program that drives myofibroblast differentiation from various precursor cell types. Crucial regulators of this transcriptional program are serum response factor (SRF) and its cofactor MKL1 (also known as MRTF-A). However, the exact mechanism of the crosstalk between TGF-β signaling and MKL1 remains unclear. Here, we report the discovery of a novel MKL1 variant/isoform, MKL1_S, transcribed from an alternative promoter and uncover a novel translation start for the published human isoform, MKL1_L. Using a human adipose-derived mesenchymal stem cell differentiation model, we show that TGF-β specifically upregulates MKL1_S during the initial phase of myofibroblast differentiation. We identified a functional N-terminal motif in MKL1_S that allows specific induction of a group of genes including the extracellular matrix (ECM) modifiers MMP16 and SPOCK3/testican-3. We propose that TGF-β-mediated induction of MKL1_S initiates progression to later stages of differentiation towards a stationary myofibroblast.
Collapse
|
23
|
Tissue decellularization by activation of programmed cell death. Biomaterials 2013; 34:6099-108. [DOI: 10.1016/j.biomaterials.2013.04.058] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2013] [Accepted: 04/27/2013] [Indexed: 01/10/2023]
|
24
|
Enhancing the biological performance of synthetic polymeric materials by decoration with engineered, decellularized extracellular matrix. Biomaterials 2012; 33:5085-93. [PMID: 22510434 DOI: 10.1016/j.biomaterials.2012.03.082] [Citation(s) in RCA: 80] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2012] [Accepted: 03/27/2012] [Indexed: 12/21/2022]
Abstract
Materials based on synthetic polymers can be extensively tailored in their physical properties but often suffer from limited biological functionality. Here we tested the hypothesis that the biological performance of 3D synthetic polymer-based scaffolds can be enhanced by extracellular matrix (ECM) deposited by cells in vitro and subsequently decellularized. The hypothesis was tested in the context of bone graft substitutes, using polyesterurethane (PEU) foams and mineralized ECM laid by human mesenchymal stromal cells (hMSC). A perfusion-based bioreactor system was critically employed to uniformly seed and culture hMSC in the scaffolds and to efficiently decellularize (94% DNA reduction) the resulting ECM while preserving its main organic and inorganic components. As compared to plain PEU, the decellularized ECM-polymer hybrids supported the osteoblastic differentiation of newly seeded hMSC by up-regulating the mRNA expression of typical osteoblastic genes (6-fold higher bone sialoprotein; 4-fold higher osteocalcin and osteopontin) and increasing calcium deposition (6-fold higher), approaching the performance of ceramic-based materials. After ectopic implantation in nude mice, the decellularized hybrids induced the formation of a mineralized matrix positively immunostained for bone sialoprotein and resembling an immature osteoid tissue. Our findings consolidate the perspective of bioreactor-based production of ECM-decorated polymeric scaffolds as off-the-shelf materials combining tunable physical properties with the physiological presentation of instructive biological signals.
Collapse
|