[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/03/2023] [Indexed: 08/06/2023]
Abstract
INTRODUCTION AND AIMS
Sodium can be measured with direct or indirect methods; abnormal plasma total protein concentration can impact on sodium measured by indirect ion-selective electrodes (ISE). Serum sodium is an important item to determine the Model for End Stage Liver Disease Sodium (MELD-Na) score, commonly used for liver graft allocation. Patients with cirrhosis usually have hypoproteinemia. The aim of this study was to determine if there was a significant difference between the MELD-Na scores calculated based on the results of two different serum sodium ISE: indirect and direct.
METHODS
This was a retrospective study; we included 166 patients that underwent liver transplant assessment, and that had paired (i.e. same date and time) direct and indirect sodium determinations. We calculated the MELD-Na scores with both sodium determinations, and we compared them.
RESULTS
There was a significant difference between MELD-Na scores; the mean difference was 0.4±1.3. If MELD-Na score had been determined by the sodium measured by the direct ISE, 69 patients (42%) would have stayed in the same place on the waiting list, 67 patients (40%) would have moved up, and 30 patients (18%) would have moved down.
CONCLUSIONS
There was a statistically significant difference between the MELD-Na scores calculated based on the two different sodium concentrations, which would theoretically result in changes in the order of the waiting list. This finding should prompt studies to assess if MELD-Na calculated based on direct methods has a better performance to predict clinically relevant outcomes.