1
|
Nicolanti F, Caccia B, Cartoni A, Emfietzoglou D, Faccini R, Incerti S, Kyriakou I, Satta M, Tran HN, Mancini-Terracciano C. Calculation of electron interaction models in N 2 and O 2. Phys Med 2023; 114:102661. [PMID: 37703804 DOI: 10.1016/j.ejmp.2023.102661] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 06/19/2023] [Accepted: 08/05/2023] [Indexed: 09/15/2023] Open
Abstract
Cosmic rays have the potential to significantly affect the atmospheric composition by increasing the rate and changing the types of chemical reactions through ion production. The amount and states of ionization, and the spatial distribution of ions produced are still open questions for atmospheric models. To precisely estimate these quantities, it is necessary to simulate particle-molecule interactions, down to very low energies. Models enabling such simulations require interaction probabilities over a broad energy range and for all energetically allowed scattering processes. In this paper, we focus on electron interaction with the two most abundant molecules in the atmosphere, i.e., N2 and O2, as an initial step. A set of elastic and inelastic cross section models for electron transportation in oxygen and nitrogen molecules valid in the energy range 10 eV - 1 MeV, is presented. Comparison is made with available theoretical and experimental data and a reasonable good agreement is observed. Stopping power is calculated and compared with published data to assess the general consistency and reliability of our results. Good overall agreement is observed, with relative differences lower than 6% with the ESTAR database.
Collapse
Affiliation(s)
- F Nicolanti
- Physics Dep., Sapienza U. of Rome, p.le Aldo Moro, 5, 00185, Rome, Italy; INFN, Sec. of Rome, p.le Aldo Moro, 2, 00185, Rome, Italy.
| | - B Caccia
- ISS(Italian National Institute of Health), V. Regina Elena, 299, 00161, Rome, Italy
| | - A Cartoni
- Chemistry Dep., Sapienza U. of Rome, p.le Aldo Moro, 5, 00185, Rome, Italy
| | - D Emfietzoglou
- Med. Phys. Lab., Dept of Medicine, University of Ioannina, 45110, Ioannina, Greece
| | - R Faccini
- Physics Dep., Sapienza U. of Rome, p.le Aldo Moro, 5, 00185, Rome, Italy; INFN, Sec. of Rome, p.le Aldo Moro, 2, 00185, Rome, Italy
| | - S Incerti
- Université de Bordeaux, CNRS, LP2I Bordeaux, UMR 5797, Chemin du Solarium, 19, 33170, Gradignan, France
| | - I Kyriakou
- Med. Phys. Lab., Dept of Medicine, University of Ioannina, 45110, Ioannina, Greece
| | - M Satta
- Chemistry Dep., Sapienza U. of Rome, p.le Aldo Moro, 5, 00185, Rome, Italy; ISMN-CNR, p. Aldo Moro, 7, 00185, Rome, Italy
| | - H N Tran
- Université de Bordeaux, CNRS, LP2I Bordeaux, UMR 5797, Chemin du Solarium, 19, 33170, Gradignan, France
| | - C Mancini-Terracciano
- Physics Dep., Sapienza U. of Rome, p.le Aldo Moro, 5, 00185, Rome, Italy; INFN, Sec. of Rome, p.le Aldo Moro, 2, 00185, Rome, Italy
| |
Collapse
|
2
|
Mancini-Terracciano C, Ambrosino A, Campana L, Cassano B, Collamati F, Faccini R, Iaccarino G, Mirabelli R, Morganti S, Nicolanti F, Pacilio M, Soriani A, Solfaroli Camillocci E. Experimental validation of an innovative approach in biokinetics study for personalised dosimetry of molecular radiation therapy treatments. Phys Med Biol 2023; 68:19NT02. [PMID: 37747087 DOI: 10.1088/1361-6560/acf910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Accepted: 09/12/2023] [Indexed: 09/26/2023]
Abstract
One of today's main challenges in molecular radiation therapy is to assess an individual dosimetry that allows treatment to be tailored to the specific patient, in accordance with the current paradigm of 'personalized medicine'. The evaluation of the absorbed doses for tumor and organs at risk in molecular radiotherapy is typically based on MIRD schema acquiring few experimental points for the assessement of biokinetic parameters. WIDMApp, the wearable individual dose monitoring apparatus, is an innovative approach for internal dosimetry based on a wearable radiation detecting system for individual biokinetics sampling, a Monte Carlo simulation for particle interaction, and an unfolding algorithm for data analysis and integrated activity determination at organ level. A prototype of a WIDMApp detector element was used to record the photon emissions in a body phantom containing 3 spheres with liquid sources (18F,64Cu and99mTc) to simulate organs having different washout. Modelling the phantom geometry on the basis of a CT scan imaging, the Monte Carlo simulation computed the contribution of each emitting sphere to the signal detected in 3 positions on the phantoms surface. Combining the simulated results with the data acquired for 120 h, the unfolding algorithm deconvolved the detected signal and assessed the decay half-life (T1/2) and initial activity values (A(0)) that best reproduces the observed exponential decays. A 3%-18% level of agreement is found between the actualA(0) andT1/2values and those obtained by means of the minimization procedure based on the Monte Carlo simulation. That resulted in an estimation of the cumulated activity <15%. Moreover, WIDMApp data redundancy has been used to mitigate some experimental occurrences that happened during data taking. A first experimental test of the WIDMApp approach to internal radiation dosimetry is presented. Studies with patients are foreseen to validate the technique in a real environment.
Collapse
Affiliation(s)
- C Mancini-Terracciano
- Department of Physics, Sapienza University of Rome, Italy
- National Institute of Nuclear Physics, INFN Rome, Italy
| | - A Ambrosino
- Department of Physics, Sapienza University of Rome, Italy
- National Institute of Nuclear Physics, INFN Rome, Italy
| | - L Campana
- Department of Physics, Sapienza University of Rome, Italy
- National Institute of Nuclear Physics, INFN Rome, Italy
- Specialty School of Medical Physics, Sapienza University of Rome, Italy
| | - B Cassano
- Medical Physics Division, IRCCS Regina Elena National Cancer Institute, Rome, Italy
| | - F Collamati
- National Institute of Nuclear Physics, INFN Rome, Italy
| | - R Faccini
- Department of Physics, Sapienza University of Rome, Italy
- National Institute of Nuclear Physics, INFN Rome, Italy
| | - G Iaccarino
- Medical Physics Division, IRCCS Regina Elena National Cancer Institute, Rome, Italy
| | - R Mirabelli
- National Institute of Nuclear Physics, INFN Rome, Italy
- Department of Scienze di Base e Applicate per l'Ingegneria (SBAI), Sapienza University of Rome, Italy
| | - S Morganti
- National Institute of Nuclear Physics, INFN Rome, Italy
| | - F Nicolanti
- Department of Physics, Sapienza University of Rome, Italy
- National Institute of Nuclear Physics, INFN Rome, Italy
| | - M Pacilio
- Medical Physics Division, Azienda Ospedaliera-Universitaria Policlinico Umberto I, Rome, Italy
| | - A Soriani
- Medical Physics Division, IRCCS Regina Elena National Cancer Institute, Rome, Italy
| | - E Solfaroli Camillocci
- National Center for Radiation Protection and Computational Physics, Italian National Institute of Health, Rome, Italy
| |
Collapse
|
3
|
Arce P, Bolst D, Bordage MC, Brown JMC, Cirrone P, Cortés-Giraldo MA, Cutajar D, Cuttone G, Desorgher L, Dondero P, Dotti A, Faddegon B, Fedon C, Guatelli S, Incerti S, Ivanchenko V, Konstantinov D, Kyriakou I, Latyshev G, Le A, Mancini-Terracciano C, Maire M, Mantero A, Novak M, Omachi C, Pandola L, Perales A, Perrot Y, Petringa G, Quesada JM, Ramos-Méndez J, Romano F, Rosenfeld AB, Sarmiento LG, Sakata D, Sasaki T, Sechopoulos I, Simpson EC, Toshito T, Wright DH. Report on G4-Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group. Med Phys 2021; 48:19-56. [PMID: 32392626 PMCID: PMC8054528 DOI: 10.1002/mp.14226] [Citation(s) in RCA: 63] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2019] [Revised: 04/26/2020] [Accepted: 04/30/2020] [Indexed: 11/05/2022] Open
Abstract
BACKGROUND Geant4 is a Monte Carlo code extensively used in medical physics for a wide range of applications, such as dosimetry, micro- and nanodosimetry, imaging, radiation protection, and nuclear medicine. Geant4 is continuously evolving, so it is crucial to have a system that benchmarks this Monte Carlo code for medical physics against reference data and to perform regression testing. AIMS To respond to these needs, we developed G4-Med, a benchmarking and regression testing system of Geant4 for medical physics. MATERIALS AND METHODS G4-Med currently includes 18 tests. They range from the benchmarking of fundamental physics quantities to the testing of Monte Carlo simulation setups typical of medical physics applications. Both electromagnetic and hadronic physics processes and models within the prebuilt Geant4 physics lists are tested. The tests included in G4-Med are executed on the CERN computing infrastructure via the use of the geant-val web application, developed at CERN for Geant4 testing. The physical observables can be compared to reference data for benchmarking and to results of previous Geant4 versions for regression testing purposes. RESULTS This paper describes the tests included in G4-Med and shows the results derived from the benchmarking of Geant4 10.5 against reference data. DISCUSSION Our results indicate that the Geant4 electromagnetic physics constructor G4EmStandardPhysics_option4 gives a good agreement with the reference data for all the tests. The QGSP_BIC_HP physics list provided an overall adequate description of the physics involved in hadron therapy, including proton and carbon ion therapy. New tests should be included in the next stage of the project to extend the benchmarking to other physical quantities and application scenarios of interest for medical physics. CONCLUSION The results presented and discussed in this paper will aid users in tailoring physics lists to their particular application.
Collapse
Affiliation(s)
| | - D Bolst
- Centre For Medical Radiation Physics, University of Wollongong, Wollongong, Australia
| | - M-C Bordage
- CRCT (INSERM and Paul Sabatier University), Toulouse, France
| | - J M C Brown
- Department of Radiation Science and Technology, Delft University of Technology, Delft, The Netherlands
| | | | | | - D Cutajar
- Centre For Medical Radiation Physics, University of Wollongong, Wollongong, Australia
| | | | - L Desorgher
- Institute of Radiation Physics (IRA), Lausanne University Hospital, Lausanne, Switzerland
| | | | - A Dotti
- SLAC National Accelerator Laboratory, Stanford, CA, USA
| | - B Faddegon
- University of California, San Francisco, CA, USA
| | - C Fedon
- Radboud University Medical Center, Nijmegen, The Netherlands
| | - S Guatelli
- Centre For Medical Radiation Physics, University of Wollongong, Wollongong, Australia
| | - S Incerti
- Université de Bordeaux, CNRS/IN2P3, UMR5797, Centre d'Études Nucléaires de Bordeaux Gradignan, Gradignan, France
| | - V Ivanchenko
- Tomsk State University, Tomsk, Russian Federation
- CERN, Geneva, Switzerland
| | - D Konstantinov
- NRC "Kurchatov Institute" - IHEP, Protvino, Russian Federation
| | - I Kyriakou
- Medical Physics Laboratory, University of Ioannina, Ioannina, Greece
| | - G Latyshev
- NRC "Kurchatov Institute" - IHEP, Protvino, Russian Federation
| | - A Le
- Centre For Medical Radiation Physics, University of Wollongong, Wollongong, Australia
| | | | | | | | | | - C Omachi
- Nagoya Proton Therapy Center, Nagoya, Japan
| | | | - A Perales
- Medical Physics Department of Clínica Universidad de Navarra, Pamplona, Spain
| | - Y Perrot
- IRSN, Fontenay-aux-Roses, France
| | | | | | | | - F Romano
- INFN Catania Section, Catania, Italy
- Medical Physics Department, National Physical Laboratory, Teddington, UK
| | - A B Rosenfeld
- Centre For Medical Radiation Physics, University of Wollongong, Wollongong, Australia
| | | | - D Sakata
- Centre For Medical Radiation Physics, University of Wollongong, Wollongong, Australia
| | | | - I Sechopoulos
- Radboud University Medical Center, Nijmegen, The Netherlands
- Dutch Expert Center for Screening (LRCB), Nijmegen, The Netherlands
| | - E C Simpson
- Department of Nuclear Physics, Research School of Physics, Australian National University, Canberra, Australia
| | - T Toshito
- Nagoya Proton Therapy Center, Nagoya, Japan
| | - D H Wright
- SLAC National Accelerator Laboratory, Stanford, CA, USA
| |
Collapse
|
4
|
Fischetti M, Baroni G, Battistoni G, Bisogni G, Cerello P, Ciocca M, De Maria P, De Simoni M, Di Lullo B, Donetti M, Dong Y, Embriaco A, Ferrero V, Fiorina E, Franciosini G, Galante F, Kraan A, Luongo C, Magi M, Mancini-Terracciano C, Marafini M, Malekzadeh E, Mattei I, Mazzoni E, Mirabelli R, Mirandola A, Morrocchi M, Muraro S, Patera V, Pennazio F, Schiavi A, Sciubba A, Solfaroli Camillocci E, Sportelli G, Tampellini S, Toppi M, Traini G, Valle SM, Vischioni B, Vitolo V, Sarti A. Inter-fractional monitoring of [Formula: see text]C ions treatments: results from a clinical trial at the CNAO facility. Sci Rep 2020; 10:20735. [PMID: 33244102 PMCID: PMC7693236 DOI: 10.1038/s41598-020-77843-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Accepted: 11/13/2020] [Indexed: 12/26/2022] Open
Abstract
The high dose conformity and healthy tissue sparing achievable in Particle Therapy when using C ions calls for safety factors in treatment planning, to prevent the tumor under-dosage related to the possible occurrence of inter-fractional morphological changes during a treatment. This limitation could be overcome by a range monitor, still missing in clinical routine, capable of providing on-line feedback. The Dose Profiler (DP) is a detector developed within the INnovative Solution for In-beam Dosimetry in hadronthErapy (INSIDE) collaboration for the monitoring of carbon ion treatments at the CNAO facility (Centro Nazionale di Adroterapia Oncologica) exploiting the detection of charged secondary fragments that escape from the patient. The DP capability to detect inter-fractional changes is demonstrated by comparing the obtained fragment emission maps in different fractions of the treatments enrolled in the first ever clinical trial of such a monitoring system, performed at CNAO. The case of a CNAO patient that underwent a significant morphological change is presented in detail, focusing on the implications that can be drawn for the achievable inter-fractional monitoring DP sensitivity in real clinical conditions. The results have been cross-checked against a simulation study.
Collapse
Affiliation(s)
- M. Fischetti
- Dipartimento di Scienze di Base e Applicate per l’Ingegneria, Sapienza Università di Roma, Rome, Italy
- INFN Sezione di Roma I, Rome, Italy
| | - G. Baroni
- Dipartimento di Elettronica Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | | | - G. Bisogni
- INFN Sezione di Pisa, Pisa, Italy
- Dipartimento di Fisica “E. Fermi”, Università di Pisa, Pisa, Italy
| | | | - M. Ciocca
- CNAO Centro Nazionale di Adroterapia Oncologica, Pavia, Italy
| | - P. De Maria
- Scuola di Specializzazione di Fisica Medica, Sapienza Università di Roma, Rome, Italy
| | - M. De Simoni
- Dipartimento di Fisica, Sapienza Università di Roma, Rome, Italy
- INFN Sezione di Roma I, Rome, Italy
| | - B. Di Lullo
- Dipartimento di Scienze di Base e Applicate per l’Ingegneria, Sapienza Università di Roma, Rome, Italy
| | - M. Donetti
- CNAO Centro Nazionale di Adroterapia Oncologica, Pavia, Italy
| | - Y. Dong
- INFN Sezione di Milano, Milan, Italy
- Dipartimento di Fisica, Università degli Studi di Milano, Milan, Italy
| | | | | | - E. Fiorina
- INFN Sezione di Torino, Turin, Italy
- CNAO Centro Nazionale di Adroterapia Oncologica, Pavia, Italy
| | - G. Franciosini
- Dipartimento di Fisica, Sapienza Università di Roma, Rome, Italy
- INFN Sezione di Roma I, Rome, Italy
| | - F. Galante
- Dipartimento di Scienze di Base e Applicate per l’Ingegneria, Sapienza Università di Roma, Rome, Italy
| | - A. Kraan
- INFN Sezione di Pisa, Pisa, Italy
| | - C. Luongo
- INFN Sezione di Pisa, Pisa, Italy
- Dipartimento di Chimica e Chimica Industriale, Università di Pisa, Pisa, Italy
| | - M. Magi
- Dipartimento di Scienze di Base e Applicate per l’Ingegneria, Sapienza Università di Roma, Rome, Italy
| | - C. Mancini-Terracciano
- Dipartimento di Fisica, Sapienza Università di Roma, Rome, Italy
- INFN Sezione di Roma I, Rome, Italy
| | - M. Marafini
- INFN Sezione di Roma I, Rome, Italy
- Museo Storico della Fisica e Centro Studi e Ricerche “E. Fermi”, Rome, Italy
| | - E. Malekzadeh
- CNAO Centro Nazionale di Adroterapia Oncologica, Pavia, Italy
| | - I. Mattei
- INFN Sezione di Milano, Milan, Italy
| | | | - R. Mirabelli
- Dipartimento di Fisica, Sapienza Università di Roma, Rome, Italy
- INFN Sezione di Roma I, Rome, Italy
- Museo Storico della Fisica e Centro Studi e Ricerche “E. Fermi”, Rome, Italy
| | - A. Mirandola
- CNAO Centro Nazionale di Adroterapia Oncologica, Pavia, Italy
| | - M. Morrocchi
- INFN Sezione di Pisa, Pisa, Italy
- Dipartimento di Fisica “E. Fermi”, Università di Pisa, Pisa, Italy
| | - S. Muraro
- INFN Sezione di Milano, Milan, Italy
| | - V. Patera
- Dipartimento di Scienze di Base e Applicate per l’Ingegneria, Sapienza Università di Roma, Rome, Italy
- INFN Sezione di Roma I, Rome, Italy
- Museo Storico della Fisica e Centro Studi e Ricerche “E. Fermi”, Rome, Italy
| | | | - A. Schiavi
- Dipartimento di Scienze di Base e Applicate per l’Ingegneria, Sapienza Università di Roma, Rome, Italy
- INFN Sezione di Roma I, Rome, Italy
| | - A. Sciubba
- Dipartimento di Scienze di Base e Applicate per l’Ingegneria, Sapienza Università di Roma, Rome, Italy
- INFN Sezione dei Laboratori di Frascati, Rome, Italy
- Museo Storico della Fisica e Centro Studi e Ricerche “E. Fermi”, Rome, Italy
| | - E. Solfaroli Camillocci
- Dipartimento di Fisica, Sapienza Università di Roma, Rome, Italy
- INFN Sezione di Roma I, Rome, Italy
- Scuola di Specializzazione in Fisica Medica, Sapienza Università di Roma, Rome, Italy
| | - G. Sportelli
- INFN Sezione di Pisa, Pisa, Italy
- Dipartimento di Fisica “E. Fermi”, Università di Pisa, Pisa, Italy
| | - S. Tampellini
- CNAO Centro Nazionale di Adroterapia Oncologica, Pavia, Italy
| | - M. Toppi
- Dipartimento di Scienze di Base e Applicate per l’Ingegneria, Sapienza Università di Roma, Rome, Italy
- INFN Sezione dei Laboratori di Frascati, Rome, Italy
| | - G. Traini
- INFN Sezione di Roma I, Rome, Italy
- Museo Storico della Fisica e Centro Studi e Ricerche “E. Fermi”, Rome, Italy
| | | | - B. Vischioni
- CNAO Centro Nazionale di Adroterapia Oncologica, Pavia, Italy
| | - V. Vitolo
- CNAO Centro Nazionale di Adroterapia Oncologica, Pavia, Italy
| | - A. Sarti
- Dipartimento di Scienze di Base e Applicate per l’Ingegneria, Sapienza Università di Roma, Rome, Italy
- INFN Sezione di Roma I, Rome, Italy
- Museo Storico della Fisica e Centro Studi e Ricerche “E. Fermi”, Rome, Italy
| |
Collapse
|
5
|
Ciardiello A, Asai M, Caccia B, Cirrone GAP, Colonna M, Dotti A, Faccini R, Giagu S, Messina A, Napolitani P, Pandola L, Wright DH, Mancini-Terracciano C. Preliminary results in using Deep Learning to emulate BLOB, a nuclear interaction model. Phys Med 2020; 73:65-72. [PMID: 32330813 DOI: 10.1016/j.ejmp.2020.04.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Revised: 03/17/2020] [Accepted: 04/03/2020] [Indexed: 11/27/2022] Open
Abstract
PURPOSE A reliable model to simulate nuclear interactions is fundamental for Ion-therapy. We already showed how BLOB ("Boltzmann-Langevin One Body"), a model developed to simulate heavy ion interactions up to few hundreds of MeV/u, could simulate also 12C reactions in the same energy domain. However, its computation time is too long for any medical application. For this reason we present the possibility of emulating it with a Deep Learning algorithm. METHODS The BLOB final state is a Probability Density Function (PDF) of finding a nucleon in a position of the phase space. We discretised this PDF and trained a Variational Auto-Encoder (VAE) to reproduce such a discrete PDF. As a proof of concept, we developed and trained a VAE to emulate BLOB in simulating the interactions of 12C with 12C at 62 MeV/u. To have more control on the generation, we forced the VAE latent space to be organised with respect to the impact parameter (b) training a classifier of b jointly with the VAE. RESULTS The distributions obtained from the VAE are similar to the input ones and the computation time needed to use the VAE as a generator is negligible. CONCLUSIONS We show that it is possible to use a Deep Learning approach to emulate a model developed to simulate nuclear reactions in the energy range of interest for Ion-therapy. We foresee the implementation of the generation part in C++ and to interface it with the most used Monte Carlo toolkit: Geant4.
Collapse
Affiliation(s)
- A Ciardiello
- Dip. Fisica, Sapienza Univ. di Roma, Rome, Italy; INFN Sezione di Roma, Rome, Italy
| | - M Asai
- SLAC National Accelerator Laboratory, Menlo Park, United States
| | - B Caccia
- National Center for Radiation Protection and Computational Physics, Istituto Superiore di Sanitá, Italy
| | | | - M Colonna
- INFN, Laboratori Nazionali del Sud, Catania, Italy
| | - A Dotti
- SLAC National Accelerator Laboratory, Menlo Park, United States
| | - R Faccini
- Dip. Fisica, Sapienza Univ. di Roma, Rome, Italy; INFN Sezione di Roma, Rome, Italy
| | - S Giagu
- Dip. Fisica, Sapienza Univ. di Roma, Rome, Italy; INFN Sezione di Roma, Rome, Italy
| | - A Messina
- Dip. Fisica, Sapienza Univ. di Roma, Rome, Italy; INFN Sezione di Roma, Rome, Italy
| | - P Napolitani
- Université Paris-Saclay, CNRS/IN2P3, IJCLab, 91405 Orsay, France
| | - L Pandola
- INFN, Laboratori Nazionali del Sud, Catania, Italy
| | - D H Wright
- SLAC National Accelerator Laboratory, Menlo Park, United States
| | - C Mancini-Terracciano
- Dip. Fisica, Sapienza Univ. di Roma, Rome, Italy; INFN Sezione di Roma, Rome, Italy.
| |
Collapse
|
6
|
Morganti S, Bertani E, Bocci V, Colandrea M, Collamati F, Cremonesi M, De Simoni M, Ferrari E, Fischetti M, Funicelli L, Grana CM, Mancini-Terracciano C, Mirabelli R, Papi S, Pisa E, Solfaroli-Camillocci E, Traini G, Faccini R. Tumor-non-tumor discrimination by a β - detector for Radio Guided Surgery on ex-vivo neuroendocrine tumors samples. Phys Med 2020; 72:96-102. [PMID: 32247965 DOI: 10.1016/j.ejmp.2020.03.021] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2019] [Revised: 03/20/2020] [Accepted: 03/23/2020] [Indexed: 01/06/2023] Open
Abstract
This paper provides a first insight of the potential of the β- Radio Guided Surgery (β--RGS) in a complex surgical environment like the abdomen, where multiple sources of background concur to the signal at the tumor site. This case is well reproduced by ex-vivo samples of 90Y-marked Gastro-Entero-Pancreatic Neuroendocrine Tumors (GEP NET) in the bowel. These specimens indeed include at least three wide independent sources of background associated to three anatomical districts (mesentery, intestine, mucose). The study is based on the analysis of 37 lesions found on 5 samples belonging to 5 different patients. We show that the use of electrons, a short range particle, instead of γ particles, allows to limit counts read on a lesion to the sum of the tumor signal plus the background generated by the sole hosting district.The background on adjacent districts in the same specimen/patient is found to differ up to a factor 4, showing how the specificity and sensitivity of the β--RGS technique can be fully exploited only upon a correct measurement of the contributing background. This locality has been used to set a site-specific cut-off algorithm to discriminate tumor and healthy tissue with a specificity of 100% and a sensitivity, on this test data sample, close to 100%. Factors influencing the sensitivity are also discussed. One of the specimens set allowed us evaluate the volume of the lesions, thus concluding that the probe was able to detect lesions as small as 0.04 mL in that particular case.
Collapse
Affiliation(s)
- S Morganti
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Rome, Italy
| | - E Bertani
- Division of Digestive Surgery, IEO, European Institute of Oncology IRCCS, Milan, Italy
| | - V Bocci
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Rome, Italy
| | - M Colandrea
- Division of Nuclear Medicine, IEO, European Institute of Oncology IRCCS, Milan, Italy
| | - F Collamati
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Rome, Italy.
| | - M Cremonesi
- Radiation Research Unit, IEO, European Institute of Oncology IRCCS, Milan, Italy
| | - M De Simoni
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Rome, Italy; Dipartimento di Fisica, Sapienza Università di Roma, Rome, Italy
| | - E Ferrari
- Division of Medical Physics, IEO, European Institute of Oncology IRCCS, Milan, Italy
| | - M Fischetti
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Rome, Italy; Dipartimento Scienze di Base e Applicate per l'Ingegneria, Sapienza Università di Roma, Rome, Italy
| | - L Funicelli
- Division of Radiology, IEO, European Institute of Oncology IRCCS, Milan, Italy
| | - C M Grana
- Division of Nuclear Medicine, IEO, European Institute of Oncology IRCCS, Milan, Italy
| | - C Mancini-Terracciano
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Rome, Italy; Dipartimento di Fisica, Sapienza Università di Roma, Rome, Italy
| | - R Mirabelli
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Rome, Italy; Dipartimento di Fisica, Sapienza Università di Roma, Rome, Italy; Dipartimento Scienze di Base e Applicate per l'Ingegneria, Sapienza Università di Roma, Rome, Italy; Museo Storico della Fisica e Centro Studi e Ricerche E. Fermi, Rome, Italy
| | - S Papi
- Division of Nuclear Medicine, IEO, European Institute of Oncology IRCCS, Milan, Italy
| | - E Pisa
- Division of Pathology, IEO, European Institute of Oncology IRCCS, Milan, Italy
| | - E Solfaroli-Camillocci
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Rome, Italy; Scuola di Specializzazione in Fisica Medica, Sapienza Università di Roma, Rome, Italy
| | - G Traini
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Rome, Italy; Dipartimento di Fisica, Sapienza Università di Roma, Rome, Italy; Dipartimento Scienze di Base e Applicate per l'Ingegneria, Sapienza Università di Roma, Rome, Italy; Museo Storico della Fisica e Centro Studi e Ricerche E. Fermi, Rome, Italy
| | - R Faccini
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Rome, Italy; Dipartimento di Fisica, Sapienza Università di Roma, Rome, Italy
| |
Collapse
|
7
|
Mancini-Terracciano C, Asai M, Caccia B, Cirrone GAP, Dotti A, Faccini R, Napolitani P, Pandola L, Wright DH, Colonna M. Preliminary results coupling "Stochastic Mean Field" and "Boltzmann-Langevin One Body" models with Geant4. Phys Med 2019; 67:116-122. [PMID: 31706147 DOI: 10.1016/j.ejmp.2019.10.026] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2019] [Revised: 10/02/2019] [Accepted: 10/13/2019] [Indexed: 11/15/2022] Open
Abstract
PURPOSE Monte Carlo (MC) simulations are widely used for medical applications and nuclear reaction models are fundamental for the simulation of the particle interactions with patients in ion therapy. Therefore, it is of utmost importance to have reliable models in MC simulations for such interactions. Geant4 is one of the most used toolkits for MC simulation. However, its models showed severe limitations in reproducing the yields measured in the interaction of ion beams below 100 MeV/u with thin targets. For this reason, we interfaced two models, SMF ("Stochastic Mean Field") and BLOB ("Boltzmann-Langevin One Body"), dedicated to simulate such reactions, with Geant4. METHODS Both SMF and BLOB are semi-classical, one-body approaches to solve the Boltzmann-Langevin equation. They include an identical treatment of the mean-field propagation, on the basis of the same effective interaction, but they differ in the way fluctuations are included. Furthermore, we tested a correction to the excitation energy calculated for the light fragments emerging from the simulations and a simple coalescence model. RESULTS While both SMF and BLOB have been developed to simulate heavy ion interactions, they show very good results in reproducing the experimental yields of light fragments, up to alpha particles, obtained in the interaction of 12C with a thin carbon target at 62 MeV/u. CONCLUSIONS BLOB in particular gives promising results and this stresses the importance of integrating it into the Geant4 toolkit.
Collapse
Affiliation(s)
- C Mancini-Terracciano
- Dip. Fisica, Sapienza Univ. di Roma, Rome, Italy; INFN Sezione di Roma, Rome, Italy.
| | - M Asai
- SLAC National Accelerator Laboratory, Menlo Park, United States
| | - B Caccia
- National Center for Radiation Protection and Computational Physics, Istituto Superiore di Sanit, Italy
| | | | - A Dotti
- SLAC National Accelerator Laboratory, Menlo Park, United States
| | - R Faccini
- Dip. Fisica, Sapienza Univ. di Roma, Rome, Italy; INFN Sezione di Roma, Rome, Italy
| | - P Napolitani
- IPN, CNRS/IN2P3, Université Paris-Sud 11, UniversitéParis-Saclay, 91406 Orsay Cedex, France
| | - L Pandola
- INFN, Laboratori Nazionali del Sud, Catania, Italy
| | - D H Wright
- SLAC National Accelerator Laboratory, Menlo Park, United States
| | - M Colonna
- INFN, Laboratori Nazionali del Sud, Catania, Italy
| |
Collapse
|
8
|
Collamati F, Moretti R, Alunni-Solestizi L, Bocci V, Cartoni A, Collarino A, De Simoni M, Faccini R, Fischetti M, Giordano A, Maccora D, Mancini-Terracciano C, Mirabelli R, Scotognella T, Solfaroli-Camillocci E, Traini G, Morganti S. Characterisation of a β detector on positron emitters for medical applications. Phys Med 2019; 67:85-90. [PMID: 31704391 DOI: 10.1016/j.ejmp.2019.10.025] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2019] [Revised: 10/02/2019] [Accepted: 10/09/2019] [Indexed: 12/21/2022] Open
Abstract
PURPOSE Radio Guided Surgery (RGS) is a technique that helps the surgeon to achieve an as complete as possible tumor resection, thanks to the intraoperative detection of particles emitted by a radio tracer that bounds to tumoral cells. In the last years, a novel approach to this technique has been proposed that, exploiting β- emitting radio tracers, overtakes some limitations of established γ-RGS. In this context, a first prototype of an intraoperative β particle detector, based on a high light yield and low density organic scintillator, has been developed and characterised on pure β- emitters, like 90Y. The demonstrated very high efficiency to β- particles, together with the remarkable transparency to photons, suggested the possibility to use this detector also with β+ emitting sources, that have plenty of applications in nuclear medicine. In this paper, we present upgrades and optimisations performed to the detector to reveal such particles. METHODS Laboratory measurement have been performed on liquid Ga68 source, and were used to validate and tune a Monte Carlo simulation. RESULTS The upgraded detector has an ~80% efficiency to electrons above ~110keV, reaching a plateau value of ~95%. At the same time, the probe is substantially transparent to photons below ~200keV, reaching a plateau value of ~3%. CONCLUSIONS The new prototype seems to have promising characteristics to perform RGS also with β+ emitting isotopes.
Collapse
Affiliation(s)
- F Collamati
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Roma, Italy
| | - R Moretti
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Roma, Italy; Dipartimento di Fisica, Sapienza Università di Roma, Roma, Italy
| | - L Alunni-Solestizi
- Istituto Nazionale di Fisica Nucleare, Sezione di Perugia, Perugia, Italy
| | - V Bocci
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Roma, Italy
| | - A Cartoni
- Dipartimento di Chimica, Sapienza Università di Roma, Roma, Italy
| | - A Collarino
- Unità di Medicina Nucleare, Fondazione Policlinico Gemelli IRCCS, L.go A. Gemelli 8, Roma, Italy
| | - M De Simoni
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Roma, Italy; Dipartimento di Fisica, Sapienza Università di Roma, Roma, Italy
| | - R Faccini
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Roma, Italy; Dipartimento di Fisica, Sapienza Università di Roma, Roma, Italy
| | - M Fischetti
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Roma, Italy; Dipartimento Scienze di Base e Applicate per l'Ingegneria, Sapienza Università di Roma, Roma, Italy
| | - A Giordano
- Unità di Medicina Nucleare, Fondazione Policlinico Gemelli IRCCS, L.go A. Gemelli 8, Roma, Italy; Università Cattolica del Sacro Cuore, L.go F. Vito 1, 00168 Roma, Italy
| | - D Maccora
- Unità di Medicina Nucleare, Fondazione Policlinico Gemelli IRCCS, L.go A. Gemelli 8, Roma, Italy; Università Cattolica del Sacro Cuore, L.go F. Vito 1, 00168 Roma, Italy
| | | | - R Mirabelli
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Roma, Italy; Dipartimento di Fisica, Sapienza Università di Roma, Roma, Italy; Museo Storico della Fisica e Centro Studi e Ricerche E. Fermi, Rome, Italy
| | - T Scotognella
- Unità di Medicina Nucleare, Fondazione Policlinico Gemelli IRCCS, L.go A. Gemelli 8, Roma, Italy
| | - E Solfaroli-Camillocci
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Roma, Italy; Dipartimento di Fisica, Sapienza Università di Roma, Roma, Italy; Scuola di Specializzazione in Fisica Medica, Sapienza Università di Roma, Roma, Italy.
| | - G Traini
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Roma, Italy; Dipartimento di Fisica, Sapienza Università di Roma, Roma, Italy; Museo Storico della Fisica e Centro Studi e Ricerche E. Fermi, Rome, Italy
| | - S Morganti
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Roma, Italy
| |
Collapse
|
9
|
Rucinski A, Traini G, Roldan AB, Battistoni G, De Simoni M, Dong Y, Fischetti M, Frallicciardi PM, Gioscio E, Mancini-Terracciano C, Marafini M, Mattei I, Mirabelli R, Muraro S, Sarti A, Schiavi A, Sciubba A, Solfaroli Camillocci E, Valle SM, Patera V. Secondary radiation measurements for particle therapy applications: Charged secondaries produced by 16O ion beams in a PMMA target at large angles. Phys Med 2019; 64:45-53. [PMID: 31515035 DOI: 10.1016/j.ejmp.2019.06.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/24/2018] [Revised: 05/23/2019] [Accepted: 06/07/2019] [Indexed: 11/27/2022] Open
Abstract
Particle therapy is a therapy technique that exploits protons or light ions to irradiate tumor targets with high accuracy. Protons and 12C ions are already used for irradiation in clinical routine, while new ions like 4He and 16O are currently being considered. Despite the indisputable physical and biological advantages of such ion beams, the planning of charged particle therapy treatments is challenged by range uncertainties, i.e. the uncertainty on the position of the maximal dose release (Bragg Peak - BP), during the treatment. To ensure correct 'in-treatment' dose deposition, range monitoring techniques, currently missing in light ion treatment techniques, are eagerly needed. The results presented in this manuscript indicate that charged secondary particles, mainly protons, produced by an 16O beam during target irradiation can be considered as candidates for 16O beam range monitoring. Hereafter, we report on the first yield measurements of protons, deuterons and tritons produced in the interaction of an 16O beam impinging on a PMMA target, as a function of detected energy and particle production position. Charged particles were detected at 90° and 60° with respect to incoming beam direction, and homogeneous and heterogeneous PMMA targets were used to probe the sensitivity of the technique to target inhomogeneities. The reported secondary particle yields provide essential information needed to assess the accuracy and resolution achievable in clinical conditions by range monitoring techniques based on secondary charged radiation.
Collapse
Affiliation(s)
- A Rucinski
- INFN - Sezione di Roma 1, Italy; Institute of Nuclear Physics PAN, Krakow, Poland
| | - G Traini
- Dipartimento di Fisica, Sapienza Università di Roma, Roma, Italy; INFN - Sezione di Roma 1, Italy; Museo Storico della Fisica e Centro Studi e Ricerche "E. Fermi", Roma, Italy.
| | | | | | - M De Simoni
- Dipartimento di Fisica, Sapienza Università di Roma, Roma, Italy; INFN - Sezione di Roma 1, Italy
| | - Y Dong
- INFN - Sezione di Milano, Italy; Dipartimento di Fisica, Università di Milano, Milano, Italy
| | - M Fischetti
- Dipartimento di Scienze di Base e Applicate per Ingegneria, Sapienza Università di Roma, Roma, Italy; INFN - Sezione di Roma 1, Italy
| | - P M Frallicciardi
- Azienda Ospedaliero-Universitaria 'Ospedali Riuniti di Foggia', Foggia, Italy; Museo Storico della Fisica e Centro Studi e Ricerche "E. Fermi", Roma, Italy
| | - E Gioscio
- Museo Storico della Fisica e Centro Studi e Ricerche "E. Fermi", Roma, Italy
| | - C Mancini-Terracciano
- INFN - Sezione di Roma 1, Italy; Dipartimento di Fisica, Sapienza Università di Roma, Roma, Italy
| | - M Marafini
- Museo Storico della Fisica e Centro Studi e Ricerche "E. Fermi", Roma, Italy; INFN - Sezione di Roma 1, Italy
| | | | - R Mirabelli
- Dipartimento di Fisica, Sapienza Università di Roma, Roma, Italy; INFN - Sezione di Roma 1, Italy; Museo Storico della Fisica e Centro Studi e Ricerche "E. Fermi", Roma, Italy
| | | | - A Sarti
- Dipartimento di Scienze di Base e Applicate per Ingegneria, Sapienza Università di Roma, Roma, Italy; Laboratori Nazionali di Frascati dell'INFN, Frascati, Italy; Museo Storico della Fisica e Centro Studi e Ricerche "E. Fermi", Roma, Italy
| | - A Schiavi
- Dipartimento di Scienze di Base e Applicate per Ingegneria, Sapienza Università di Roma, Roma, Italy; INFN - Sezione di Roma 1, Italy
| | - A Sciubba
- Dipartimento di Scienze di Base e Applicate per Ingegneria, Sapienza Università di Roma, Roma, Italy; INFN - Sezione di Roma 1, Italy; Museo Storico della Fisica e Centro Studi e Ricerche "E. Fermi", Roma, Italy
| | - E Solfaroli Camillocci
- INFN - Sezione di Roma 1, Italy; Dipartimento di Fisica, Sapienza Università di Roma, Roma, Italy; Scuola di Specializzazione in Fisica Medica, Sapienza Università di Roma, Roma, Italy
| | - S M Valle
- INFN - Sezione di Milano, Italy; Dipartimento di Fisica, Università di Milano, Milano, Italy
| | - V Patera
- Dipartimento di Scienze di Base e Applicate per Ingegneria, Sapienza Università di Roma, Roma, Italy; INFN - Sezione di Roma 1, Italy; Museo Storico della Fisica e Centro Studi e Ricerche "E. Fermi", Roma, Italy
| |
Collapse
|
10
|
Traini G, Mattei I, Battistoni G, Bisogni MG, De Simoni M, Dong Y, Embriaco A, Fischetti M, Magi M, Mancini-Terracciano C, Marafini M, Mirabelli R, Muraro S, Patera V, Schiavi A, Sciubba A, Solfaroli Camillocci E, Valle SM, Sarti A. Review and performance of the Dose Profiler, a particle therapy treatments online monitor. Phys Med 2019; 65:84-93. [PMID: 31437603 DOI: 10.1016/j.ejmp.2019.07.010] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/06/2019] [Revised: 06/24/2019] [Accepted: 07/14/2019] [Indexed: 11/27/2022] Open
Abstract
Particle therapy (PT) can exploit heavy ions (such as He, C or O) to enhance the treatment efficacy, profiting from the increased Relative Biological Effectiveness and Oxygen Enhancement Ratio of these projectiles with respect to proton beams. To maximise the gain in tumor control probability a precise online monitoring of the dose release is needed, avoiding unnecessary large safety margins surroundings the tumor volume accounting for possible patient mispositioning or morphological changes with respect to the initial CT scan. The Dose Profiler (DP) detector, presented in this manuscript, is a scintillating fibres tracker of charged secondary particles (mainly protons) that will be operating during the treatment, allowing for an online range monitoring. Such monitoring technique is particularly promising in the context of heavy ions PT, in which the precision achievable by other techniques based on secondary photons detection is limited by the environmental background during the beam delivery. Developed and built at the SBAI department of "La Sapienza", within the INSIDE collaboration and as part of a Centro Fermi flagship project, the DP is a tracker detector specifically designed and planned for clinical applications inside a PT treatment room. The DP operation in clinical like conditions has been tested with the proton and carbon ions beams of Trento proton-therapy center and of the CNAO facility. In this contribution the detector performances are presented, in the context of the carbon ions monitoring clinical trial that is about to start at the CNAO centre.
Collapse
Affiliation(s)
- G Traini
- Dipartimento di Fisica, Sapienza Università di Roma, Italy; INFN Sezione di Roma, Italy; Museo Storico della Fisica e Centro Studi e Ricerche "E. Fermi", Roma, Italy
| | | | | | - M G Bisogni
- INFN Sezione di Pisa, Italy; Dipartimento di Fisica "E. Fermi", Università di Pisa, Pisa, Italy.
| | - M De Simoni
- Dipartimento di Fisica, Sapienza Università di Roma, Italy; INFN Sezione di Roma, Italy
| | - Y Dong
- INFN Sezione di Milano, Italy; Dipartimento di Fisica, Università degli Studi di Milano, Italy
| | | | - M Fischetti
- Dipartimento di Scienze di Base e Applicate per l'Ingegneria, Sapienza Università di Roma, Italy; INFN Sezione di Roma, Italy
| | - M Magi
- Dipartimento di Scienze di Base e Applicate per l'Ingegneria, Sapienza Università di Roma, Italy; INFN Sezione di Roma, Italy
| | - C Mancini-Terracciano
- Dipartimento di Fisica, Sapienza Università di Roma, Italy; INFN Sezione di Roma, Italy
| | - M Marafini
- Museo Storico della Fisica e Centro Studi e Ricerche "E. Fermi", Roma, Italy; INFN Sezione di Roma, Italy
| | - R Mirabelli
- Dipartimento di Fisica, Sapienza Università di Roma, Italy; INFN Sezione di Roma, Italy
| | | | - V Patera
- Dipartimento di Scienze di Base e Applicate per l'Ingegneria, Sapienza Università di Roma, Italy; INFN Sezione di Roma, Italy; Museo Storico della Fisica e Centro Studi e Ricerche "E. Fermi", Roma, Italy
| | - A Schiavi
- Dipartimento di Scienze di Base e Applicate per l'Ingegneria, Sapienza Università di Roma, Italy; INFN Sezione di Roma, Italy
| | - A Sciubba
- Dipartimento di Scienze di Base e Applicate per l'Ingegneria, Sapienza Università di Roma, Italy; INFN Sezione di Roma, Italy; Museo Storico della Fisica e Centro Studi e Ricerche "E. Fermi", Roma, Italy
| | - E Solfaroli Camillocci
- Dipartimento di Fisica, Sapienza Università di Roma, Italy; INFN Sezione di Roma, Italy; Scuola di Specializzazione in Fisica Medica, Sapienza Università di Roma, Roma, Italy
| | | | - A Sarti
- Dipartimento di Scienze di Base e Applicate per l'Ingegneria, Sapienza Università di Roma, Italy; INFN Sezione dei Laboratori di Frascati, Roma, Italy; Museo Storico della Fisica e Centro Studi e Ricerche "E. Fermi", Roma, Italy
| |
Collapse
|
11
|
Ferrari R, Mancini-Terracciano C, Voena C, Rengo M, Zerunian M, Ciardiello A, Grasso S, Mare' V, Paramatti R, Russomando A, Santacesaria R, Satta A, Solfaroli Camillocci E, Faccini R, Laghi A. MR-based artificial intelligence model to assess response to therapy in locally advanced rectal cancer. Eur J Radiol 2019; 118:1-9. [PMID: 31439226 DOI: 10.1016/j.ejrad.2019.06.013] [Citation(s) in RCA: 47] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2019] [Revised: 05/31/2019] [Accepted: 06/11/2019] [Indexed: 02/08/2023]
Abstract
PURPOSE To develop and validate an Artificial Intelligence (AI) model based on texture analysis of high-resolution T2 weighted MR images able 1) to predict pathologic Complete Response (CR) and 2) to identify non-responders (NR) among patients with locally-advanced rectal cancer (LARC) after receiving neoadjuvant chemoradiotherapy (CRT). METHOD Fifty-five consecutive patients with LARC were retrospectively enrolled in this study. Patients underwent 3 T Magnetic Resonance Imaging (MRI) acquiring T2-weighted images before, during and after CRT. All patients underwent complete surgical resection and histopathology was the gold standard. Textural features were automatically extracted using an open-source software. A sub-set of statistically significant textural features was selected and two AI models were built by training a Random Forest (RF) classifier on 28 patients (training cohort). Model performances were estimated on 27 patients (validation cohort) using a ROC curve and a decision curve analysis. RESULTS Sixteen of 55 patients achieved CR. The AI model for CR classification showed good discrimination power with mean area under the receiver operating curve (AUC) of 0.86 (95% CI: 0.70, 0.94) in the validation cohort. The discriminatory power for the NR classification showed a mean AUC of 0.83 (95% CI: 0.71,0.92). Decision curve analysis confirmed higher net patient benefit when using AI models compared to standard-of-care. CONCLUSIONS AI models based on textural features of MR images of patients with LARC may help to identify patients who will show CR at the end of treatment and those who will not respond to therapy (NR) at an early stage of the treatment.
Collapse
Affiliation(s)
- R Ferrari
- Az. Osp. San Camillo Forlanini, Department of Emergency Radiology, Viale Gianicolense 87, 00152, Rome, Italy
| | - C Mancini-Terracciano
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Piazzale A. Moro 2, 00185, Rome, Italy
| | - C Voena
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Piazzale A. Moro 2, 00185, Rome, Italy.
| | - M Rengo
- "Sapienza", University of Rome, Department of Radiological Science, Oncology and Pathology, Polo Pontino, Icot Hospital, via Franco Faggiana 1680, 04100, Latina, Italy
| | - M Zerunian
- "Sapienza", University of Rome, Department of Radiological Science, Oncology and Pathology, Polo Pontino, Icot Hospital, via Franco Faggiana 1680, 04100, Latina, Italy
| | - A Ciardiello
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Piazzale A. Moro 2, 00185, Rome, Italy; "Sapienza", University of Rome, Department of Physics, Piazzale A. Moro 2, 00185, Rome, Italy
| | - S Grasso
- "Sapienza", University of Rome, Department of Physics, Piazzale A. Moro 2, 00185, Rome, Italy
| | - V Mare'
- "Sapienza", University of Rome, Department of Physics, Piazzale A. Moro 2, 00185, Rome, Italy; University "Cattolica del Sacro Cuore", Specialty School of Medical Physics, Largo Francesco Vito 1, 00198, Rome, Italy
| | - R Paramatti
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Piazzale A. Moro 2, 00185, Rome, Italy; "Sapienza", University of Rome, Department of Physics, Piazzale A. Moro 2, 00185, Rome, Italy
| | - A Russomando
- Centro Científico Tecnológico de Valparaíso-CCTVal, Universidad Técnica Federico Santa María, Avenida España 1680, Valparaiso, Chile
| | - R Santacesaria
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Piazzale A. Moro 2, 00185, Rome, Italy
| | - A Satta
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma Tor Vergata, Via della Ricerca Scientifica 1, 00133, Rome, Italy
| | - E Solfaroli Camillocci
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Piazzale A. Moro 2, 00185, Rome, Italy; "Sapienza", University of Rome, Department of Physics, Piazzale A. Moro 2, 00185, Rome, Italy; "Sapienza", University of Rome, Specialty School of Medical Physics, Piazzale Aldo Moro 2, 00185, Rome, Italy
| | - R Faccini
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Piazzale A. Moro 2, 00185, Rome, Italy; "Sapienza", University of Rome, Department of Physics, Piazzale A. Moro 2, 00185, Rome, Italy
| | - A Laghi
- "Sapienza", University of Rome, Department of Radiological Science, Oncology and Pathology, Sant'Andrea University hospital, via di Grottarossa 1035, 00189, Rome, Italy
| |
Collapse
|
12
|
Rucinski A, Battistoni G, Collamati F, De Lucia E, Faccini R, Frallicciardi PM, Mancini-Terracciano C, Marafini M, Mattei I, Muraro S, Paramatti R, Piersanti L, Pinci D, Russomando A, Sarti A, Sciubba A, Solfaroli Camillocci E, Toppi M, Traini G, Voena C, Patera V. Secondary radiation measurements for particle therapy applications: charged particles produced by 4He and 12C ion beams in a PMMA target at large angle. Phys Med Biol 2018; 63:055018. [PMID: 29265011 DOI: 10.1088/1361-6560/aaa36a] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Proton and carbon ion beams are used in the clinical practice for external radiotherapy treatments achieving, for selected indications, promising and superior clinical results with respect to x-ray based radiotherapy. Other ions, like [Formula: see text] have recently been considered as projectiles in particle therapy centres and might represent a good compromise between the linear energy transfer and the radiobiological effectiveness of [Formula: see text] ion and proton beams, allowing improved tumour control probability and minimising normal tissue complication probability. All the currently used p, [Formula: see text] and [Formula: see text] ion beams allow achieving sharp dose gradients on the boundary of the target volume, however the accurate dose delivery is sensitive to the patient positioning and to anatomical variations with respect to photon therapy. This requires beam range and/or dose release measurement during patient irradiation and therefore the development of dedicated monitoring techniques. All the proposed methods make use of the secondary radiation created by the beam interaction with the patient and, in particular, in the case of [Formula: see text] ion beams are also able to exploit the significant charged radiation component. Measurements performed to characterise the charged secondary radiation created by [Formula: see text] and [Formula: see text] particle therapy beams are reported. Charged secondary yields, energy spectra and emission profiles produced in a poly-methyl methacrylate (PMMA) target by [Formula: see text] and [Formula: see text] beams of different therapeutic energies were measured at 60° and 90° with respect to the primary beam direction. The secondary yield of protons produced along the primary beam path in a PMMA target was obtained. The energy spectra of charged secondaries were obtained from time-of-flight information, whereas the emission profiles were reconstructed exploiting tracking detector information. The obtained measurements are in agreement with results reported in the literature and suggests the feasibility of range monitoring based on charged secondary particle detection: the implications for particle therapy monitoring applications are also discussed.
Collapse
Affiliation(s)
- A Rucinski
- INFN-Sezione di Roma, Italy. Dipartimento di Scienze di Base e Applicate per l'Ingegneria, Sapienza Università di Roma, Roma, Italy. Institute of Nuclear Physics Polish Academy of Sciences, PL-31342 Krakow, Poland
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Muraro S, Battistoni G, De Lucia E, Mancini-Terracciano C, Marafini M, Mattei I, Mirabelli R, Sarti A, Sciubba A, Solfaroli Camillocci E, Toppi M, Traini G, Valle S, Voena C, Patera V. Abstract ID: 67 MC codes and range monitoring in particle therapy: The case of secondary charged particles. Phys Med 2017. [DOI: 10.1016/j.ejmp.2017.09.143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|
14
|
Marafini M, Paramatti R, Pinci D, Battistoni G, Collamati F, De Lucia E, Faccini R, Frallicciardi PM, Mancini-Terracciano C, Mattei I, Muraro S, Piersanti L, Rovituso M, Rucinski A, Russomando A, Sarti A, Sciubba A, Solfaroli Camillocci E, Toppi M, Traini G, Voena C, Patera V. Secondary radiation measurements for particle therapy applications: nuclear fragmentation produced by4He ion beams in a PMMA target. Phys Med Biol 2017; 62:1291-1309. [DOI: 10.1088/1361-6560/aa5307] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
15
|
Mattei I, Bini F, Collamati F, De Lucia E, Frallicciardi PM, Iarocci E, Mancini-Terracciano C, Marafini M, Muraro S, Paramatti R, Patera V, Piersanti L, Pinci D, Rucinski A, Russomando A, Sarti A, Sciubba A, Solfaroli Camillocci E, Toppi M, Traini G, Voena C, Battistoni G. Secondary radiation measurements for particle therapy applications: prompt photons produced by 4He, 12C and 16O ion beams in a PMMA target. Phys Med Biol 2017; 62:1438-1455. [PMID: 28114112 DOI: 10.1088/1361-6560/62/4/1438] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
Charged particle beams are used in particle therapy (PT) to treat oncological patients due to their selective dose deposition in tissues with respect to the photons and electrons used in conventional radiotherapy. Heavy (Z > 1) PT beams can additionally be exploited for their high biological effectiveness in killing cancer cells. Nowadays, protons and carbon ions are used in PT clinical routines. Recently, interest in the potential application of helium and oxygen beams has been growing. With respect to protons, such beams are characterized by their reduced multiple scattering inside the body, increased linear energy transfer, relative biological effectiveness and oxygen enhancement ratio. The precision of PT demands online dose monitoring techniques, crucial to improving the quality assurance of any treatment: possible patient mis-positioning and biological tissue changes with respect to the planning CT scan could negatively affect the outcome of the therapy. The beam range confined in the irradiated target can be monitored thanks to the neutral or charged secondary radiation emitted by the interactions of hadron beams with matter. Among these secondary products, prompt photons are produced by nuclear de-excitation processes, and at present, different dose monitoring and beam range verification techniques based on prompt-γ detection are being proposed. It is hence of importance to perform γ yield measurement in therapeutic-like conditions. In this paper we report on the yields of prompt photons produced by the interaction of helium, carbon and oxygen ion beams with a poly-methyl methacrylate (PMMA) beam stopping target. The measurements were performed at the Heidelberg Ion-Beam Therapy Center (HIT) with beams of different energies. An LYSO scintillator, placed at [Formula: see text] and [Formula: see text] with respect to the beam direction, was used as the photon detector. The obtained γ yields for the carbon ion beams are compared with results from the literature, while no other results from helium and oxygen beams have been published yet. A discussion on the expected resolution of a slit camera detector is presented, demonstrating the feasibility of a prompt-γ-based monitoring technique for PT treatments using helium, carbon and oxygen ion beams.
Collapse
|
16
|
Rucinski A, Battistoni G, Collamati F, Collini F, De Lucia E, Faccini R, Frallicciardi P, Mancini-Terracciano C, Marafini M, Muraro S, Paramatti R, Patera V, Piersanti L, Pinci D, Russomando A, Sarti A, Sciubba A, Camillocci ES, Toppi M, Traini G, Voena C. SU-F-J-202: Secondary Radiation Measurements for Charged Particle Therapy Monitoring: Fragmentation of Therapeutic He, C and O Ion Beams Impinging On a PMMA Target. Med Phys 2016. [DOI: 10.1118/1.4956110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
17
|
Rucinski A, Battistoni G, Collamati F, Collini F, De Lucia E, Faccini R, Frallicciardi P, Mancini-Terracciano C, Marafini M, Muraro S, Paramatti R, Patera V, Piersanti L, Pinci D, Russomando A, Sarti A, Sciubba A, Camillocci ES, Toppi M, Traini G, Voena C, Rucinski A. SU-G-JeP1-13: Innovative Tracking Detector for Dose Monitoring in Hadron Therapy: Realization and Monte Carlo Simulations. Med Phys 2016. [DOI: 10.1118/1.4956988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|