1
|
Brosseau CL, Gambardella A, Casadio F, Grzywacz CM, Wouters J, Van Duyne RP. Ad-hoc Surface-Enhanced Raman Spectroscopy Methodologies for the Detection of Artist Dyestuffs: Thin Layer Chromatography-Surface Enhanced Raman Spectroscopy and in Situ On the Fiber Analysis. Anal Chem 2009; 81:3056-62. [DOI: 10.1021/ac802761v] [Citation(s) in RCA: 131] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
|
16 |
131 |
2
|
Wustholz KL, Brosseau CL, Casadio F, Van Duyne RP. Surface-enhanced Raman spectroscopy of dyes: from single molecules to the artists' canvas. Phys Chem Chem Phys 2009; 11:7350-9. [PMID: 19690705 DOI: 10.1039/b904733f] [Citation(s) in RCA: 125] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
This perspective presents recent surface-enhanced Raman spectroscopy (SERS) studies of dyes, with applications to the fields of single-molecule spectroscopy and art conservation. First we describe the development and outlook of single-molecule SERS (SMSERS). Rather than providing an exhaustive review of the literature, SMSERS experiments that we consider essential for its future development are emphasized. Shifting from single-molecule to ensemble-averaged experiments, we describe recent efforts toward SERS analysis of colorants in precious artworks. Our intention is to illustrate through these examples that the forward development of SERS is dependent upon both fundamental (e.g., SMSERS) and applied (e.g., on-the-specimen SERS of historical art objects) investigations and that the future of SERS is very bright indeed.
Collapse
|
Review |
16 |
125 |
3
|
Bicout D, Brosseau C, Martinez AS, Schmitt JM. Depolarization of multiply scattered waves by spherical diffusers: Influence of the size parameter. PHYSICAL REVIEW. E, STATISTICAL PHYSICS, PLASMAS, FLUIDS, AND RELATED INTERDISCIPLINARY TOPICS 1994; 49:1767-1770. [PMID: 9961398 DOI: 10.1103/physreve.49.1767] [Citation(s) in RCA: 120] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
|
|
31 |
120 |
4
|
Brosseau CL, Rayner KS, Casadio F, Grzywacz CM, Van Duyne RP. Surface-Enhanced Raman Spectroscopy: A Direct Method to Identify Colorants in Various Artist Media. Anal Chem 2009; 81:7443-7. [DOI: 10.1021/ac901219m] [Citation(s) in RCA: 101] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
|
16 |
101 |
5
|
Zhao L, Blackburn J, Brosseau CL. Quantitative Detection of Uric Acid by Electrochemical-Surface Enhanced Raman Spectroscopy Using a Multilayered Au/Ag Substrate. Anal Chem 2014; 87:441-7. [DOI: 10.1021/ac503967s] [Citation(s) in RCA: 76] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
|
11 |
76 |
6
|
Clarke OJR, Goodall BL, Hui HP, Vats N, Brosseau CL. Development of a SERS-Based Rapid Vertical Flow Assay for Point-of-Care Diagnostics. Anal Chem 2017; 89:1405-1410. [PMID: 28208248 DOI: 10.1021/acs.analchem.6b04710] [Citation(s) in RCA: 57] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Point-of-care (POC) diagnostic testing platforms are a growing sector of the healthcare industry as they offer the advantages of rapid provision of results, ease of use, reduced cost, and the ability to link patients to care. While many POC tests are based on chromatographic flow assay technology, this technology suffers from a lack of sensitivity along with limited capacity for multiplexing and quantitative analysis. Several recent reports have begun to investigate the feasibility of coupling chromatographic flow platforms to more advanced read-out technologies which in turn enable on-site acquisition, storage, and transmission of important healthcare metrics. One such technology being explored is surface-enhanced Raman spectroscopy or SERS. In this work, SERS is coupled for the first time to a rapid vertical flow (RVF) immunotechnology for detection of anti-HCV antibodies in an effort to extend the capabilities of this commercially available diagnostic platform. High-quality and reproducible SERS spectra were obtained using reporter-modified gold nanoparticles (AuNPs). Serial dilution studies indicate that the coupling of SERS with RVF technology shows enormous potential for next-generation POC diagnostics.
Collapse
|
Research Support, Non-U.S. Gov't |
8 |
57 |
7
|
Goodall BL, Robinson AM, Brosseau CL. Electrochemical-surface enhanced Raman spectroscopy (E-SERS) of uric acid: a potential rapid diagnostic method for early preeclampsia detection. Phys Chem Chem Phys 2013. [DOI: 10.1039/c2cp42596c] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
|
12 |
54 |
8
|
Dubreuil M, Delrot P, Leonard I, Alfalou A, Brosseau C, Dogariu A. Exploring underwater target detection by imaging polarimetry and correlation techniques. APPLIED OPTICS 2013; 52:997-1005. [PMID: 23400061 DOI: 10.1364/ao.52.000997] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2012] [Accepted: 12/21/2012] [Indexed: 06/01/2023]
Abstract
Underwater target detection is investigated by combining active polarization imaging and optical correlation-based approaches. Experiments were conducted in a glass tank filled with tap water with diluted milk or seawater and containing targets of arbitrary polarimetric responses. We found that target estimation obtained by imaging with two orthogonal polarization states always improves detection performances when correlation is used as detection criterion. This experimental study illustrates the potential of polarization imaging for underwater target detection and opens interesting perspectives for the development of underwater imaging systems.
Collapse
|
|
12 |
53 |
9
|
Li M, Chen M, Sheepwash E, Brosseau CL, Li H, Pettinger B, Gruler H, Lipkowski J. AFM studies of solid-supported lipid bilayers formed at a Au(111) electrode surface using vesicle fusion and a combination of Langmuir-Blodgett and Langmuir-Schaefer techniques. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2008; 24:10313-23. [PMID: 18712889 DOI: 10.1021/la800800m] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Atomic force microscopy (AFM) has been used to characterize the formation of a phospholipid bilayer composed of 1,2-dimyristyl-sn-glycero-3-phosphocholine (DMPC) at a Au(111) electrode surface. The bilayer was formed by one of two methods: fusion of lamellar vesicles or by the combination of Langmuir-Blodgett (LB) and Langmuir-Schaefer (LS) deposition. Results indicate that phospholipid vesicles rapidly adsorb and fuse to form a film at the electrode surface. The resulting film undergoes a very slow structural transformation until a characteristic corrugated phase is formed. Force-distance curve measurements reveal that the thickness of the corrugated phase is consistent with the thickness of a bilayer lipid membrane. The formation of the corrugated phase may be explained by considering the elastic properties of the film and taking into account spontaneous curvature induced by the asymmetric environment of the bilayer, in which one side faces the gold substrate and the other side faces the solution. The effect of temperature and electrode potential on the stability of the corrugated phase has also been described.
Collapse
|
|
17 |
45 |
10
|
Karaballi RA, Nel A, Krishnan S, Blackburn J, Brosseau CL. Development of an electrochemical surface-enhanced Raman spectroscopy (EC-SERS) aptasensor for direct detection of DNA hybridization. Phys Chem Chem Phys 2016; 17:21356-63. [PMID: 25780805 DOI: 10.1039/c4cp05077k] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Rapid detection of disease biomarkers at the patient point-of-care is essential to timely and effective treatment. The research described herein focuses on the development of an electrochemical surface-enhanced Raman spectroscopy (EC-SERS) DNA aptasensor capable of direct detection of tuberculosis (TB) DNA. Specifically, a plausible DNA biomarker present in TB patient urine was chosen as the model target for detection. Cost-effective screen printed electrodes (SPEs) modified with silver nanoparticles (AgNP) were used as the aptasensor platform, onto which the aptamer specific for the target DNA was immobilized. Direct detection of the target DNA was demonstrated through the appearance of SERS peaks characteristic for adenine, present only in the target strand. Modulation of the applied potential allowed for a sizeable increase in the observed SERS response and the use of thiol back-filling prevented non-specific adsorption of non-target DNA. To our knowledge, this work represents the first EC-SERS study of an aptasensor for the direct, label-free detection of DNA hybridization. Such a technology paves the way for rapid detection of disease biomarkers at the patient point-of-care.
Collapse
|
Research Support, Non-U.S. Gov't |
9 |
41 |
11
|
Murphy LJ, Robertson KN, Harroun SG, Brosseau CL, Werner-Zwanziger U, Moilanen J, Tuononen HM, Clyburne JAC. A simple complex on the verge of breakdown: isolation of the elusive cyanoformate ion. Science 2014; 344:75-8. [PMID: 24700853 DOI: 10.1126/science.1250808] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
Why does cyanide not react destructively with the proximal iron center at the active site of 1-aminocyclopropane-1-carboxylic acid (ACC) oxidase, an enzyme central to the biosynthesis of ethylene in plants? It has long been postulated that the cyanoformate anion, [NCCO2](-), forms and then decomposes to carbon dioxide and cyanide during this process. We have now isolated and crystallographically characterized this elusive anion as its tetraphenylphosphonium salt. Theoretical calculations show that cyanoformate has a very weak C-C bond and that it is thermodynamically stable only in low dielectric media. Solution stability studies have substantiated the latter result. We propose that cyanoformate shuttles the potentially toxic cyanide away from the low dielectric active site of ACC oxidase before breaking down in the higher dielectric medium of the cell.
Collapse
|
Research Support, Non-U.S. Gov't |
11 |
39 |
12
|
Lynk TP, Sit CS, Brosseau CL. Electrochemical Surface-Enhanced Raman Spectroscopy as a Platform for Bacterial Detection and Identification. Anal Chem 2018; 90:12639-12646. [DOI: 10.1021/acs.analchem.8b02806] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
|
7 |
38 |
13
|
Bindesri SD, Alhatab DS, Brosseau CL. Development of an electrochemical surface-enhanced Raman spectroscopy (EC-SERS) fabric-based plasmonic sensor for point-of-care diagnostics. Analyst 2018; 143:4128-4135. [DOI: 10.1039/c8an01117f] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
A plasmonic fabric-based electrode has been developed for wearable EC-SERS sensing for point-of-care applications.
Collapse
|
|
7 |
38 |
14
|
Garcia-Araez N, Brosseau CL, Rodriguez P, Lipkowski J. Layer-by-layer PMIRRAS characterization of DMPC bilayers deposited on a Au111 electrode surface. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2006; 22:10365-71. [PMID: 17129004 DOI: 10.1021/la061217v] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
A combination of Langmuir-Blodgett and Langmuir-Schaefer techniques was employed to deposit 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC) bilayers at a gold electrode surface. One leaflet consisted of hydrogen-substituted acyl chains, and the second leaflet was composed of molecules with deuterium-substituted acyl chains. This architecture allowed for layer-by-layer analysis of the structure of the bilayer. Photon polarization modulation infrared reflection absorption spectroscopy (PM-IRRAS) was used to determine the conformation and orientation of the acyl chains of DMPC molecules in the individual leaflets as a function of the potential applied to the gold electrode. The bilayer is adsorbed onto the metal surface when the field applied to the membrane does not exceed approximately 108 V/m. When adsorbed, the bottom leaflet is in contact with a hydrophobic metal surface, and the top leaflet is interacting with the aqueous solution. The asymmetry of the environment has an effect on the orientation of the DMPC molecules in each leaflet. The tilt angle of the acyl chains of the DMPC molecules in the bottom leaflet that is in contact with the gold is approximately 10 degrees smaller than that observed for the top leaflet that is exposed to the solution. These studies provide direct evidence that the structure of a phospholipid bilayer deposited at an electrode surface is affected by interaction with the metal.
Collapse
|
|
19 |
36 |
15
|
Robinson AM, Zhao L, Shah Alam MY, Bhandari P, Harroun SG, Dendukuri D, Blackburn J, Brosseau CL. The development of “fab-chips” as low-cost, sensitive surface-enhanced Raman spectroscopy (SERS) substrates for analytical applications. Analyst 2015; 140:779-85. [DOI: 10.1039/c4an01633e] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Modification of metal-coated zari fabric chips with silver nanoparticles results in sensitive, affordable SERS substrates which are useful for a wide range of chemical sensing applications.
Collapse
|
|
10 |
32 |
16
|
Lamsal R, Harroun SG, Brosseau CL, Gagnon GA. Use of surface enhanced Raman spectroscopy for studying fouling on nanofiltration membrane. Sep Purif Technol 2012. [DOI: 10.1016/j.seppur.2012.05.019] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
|
13 |
27 |
17
|
Chen M, Li M, Brosseau CL, Lipkowski J. AFM studies of the effect of temperature and electric field on the structure of a DMPC-cholesterol bilayer supported on a Au(111) electrode surface. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2009; 25:1028-1037. [PMID: 19113809 DOI: 10.1021/la802839f] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Atomic force microscopy (AFM) was used to characterize a phospholipid bilayer composed of 70 mol % 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC) and 30 mol % cholesterol, at a Au(111) electrode surface. Results indicate that addition of cholesterol relaxes membrane elastic stress, increases membrane thickness, and reduces defect density. The thickness and thermotropic properties of the mixed DMPC-cholesterol bilayer supported at the gold electrode surface are quite similar to the properties of the mixed membrane in unilamellar vesicles. The stability of the supported membrane at potentials negative to the potential of zero charge E(pzc) was investigated. This study demonstrates that the bilayer supported at the gold electrode surface is stable provided the applied potential (E - E(pzc)) is less than -0.3 V. At larger polarizations, swelling of the membrane is observed. Polarizations larger than -1 V cause electrodewetting of the bilayer from the gold surface. At these negative potentials, the bilayer remains in close proximity to the metal surface, separated from it by a approximately 2 nm thick layer of electrolyte.
Collapse
|
|
16 |
26 |
18
|
Brosseau CL, Leitch J, Bin X, Chen M, Roscoe SG, Lipkowski J. Electrochemical and PM-IRRAS a glycolipid-containing biomimetic membrane prepared using Langmuir-Blodgett/Langmuir-Schaefer deposition. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2008; 24:13058-13067. [PMID: 18925767 DOI: 10.1021/la802201h] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Differential capacitance, chronocoulometry, and polarization modulation infrared reflection absorption spectroscopy (PM-IRRAS) measurements were used to characterize the structure and orientation of a DMPC + cholesterol + GM 1 (60:30:10 mol %) bilayer supported at a Au(111) electrode surface prepared using combined Langmuir-Blodgett/Langmuir-Schaefer (LB/LS) deposition. The electrochemical measurements indicate that the incorporation of ganglioside GM 1 into the membrane significantly improves the quality of the bilayer, reflected in the very low capacitance value of approximately 0.8 microF cm (-2). An analysis of the infrared data suggests that the incorporation of the glycolipid into the membrane changes both the orientation of the lipid acyl chains in the membrane and the hydration of the membrane, particularly with respect to the interfacial region of the lipids.
Collapse
|
|
17 |
25 |
19
|
Leitch JJ, Brosseau CL, Roscoe SG, Bessonov K, Dutcher JR, Lipkowski J. Electrochemical and PM-IRRAS characterization of cholera toxin binding at a model biological membrane. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2013; 29:965-76. [PMID: 23256886 DOI: 10.1021/la304939k] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
A mixed phospholipid-cholestrol bilayer, with cholera toxin B (CTB) units attached to the monosialotetrahexosylganglioside (GM1) binding sites in the distal leaflet, was deposited on a Au(111) electrode surface. Polarization modulation infrared reflection absorption spectroscopy (PM-IRRAS) measurements were used to characterize structural and orientational changes in this model biological membrane upon binding CTB and the application of the electrode potential. The data presented in this article show that binding cholera toxin to the membrane leads to an overall increase in the tilt angle of the fatty acid chains; however, the conformation of the bilayer remains relatively constant as indicated by the small decrease in the total number of gauche conformers of acyl tails. In addition, the bound toxin caused a significant decrease in the hydration of the ester group contained within the lipid bilayer. Furthermore, changes in the applied potential had a minimal effect on the overall structure of the membrane. In contrast, our results showed significant voltage-dependent changes in the average orientation of the protein α-helices that may correspond to the voltage-gated opening and closing of the central pore that resides within the B subunit of cholera toxin.
Collapse
|
|
12 |
24 |
20
|
Karaballi RA, Merchant S, Power SR, Brosseau CL. Electrochemical surface-enhanced Raman spectroscopy (EC-SERS) study of the interaction between protein aggregates and biomimetic membranes. Phys Chem Chem Phys 2018; 20:4513-4526. [DOI: 10.1039/c7cp06838g] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
EC-SERS is used for the first time to characterize protein aggregate–biomembrane interactions.
Collapse
|
|
7 |
22 |
21
|
Vezvaie M, Brosseau CL, Lipkowski J. Electrochemical SERS study of a biomimetic membrane supported at a nanocavity patterned Ag electrode. Electrochim Acta 2013. [DOI: 10.1016/j.electacta.2013.03.139] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
|
12 |
22 |
22
|
Harroun SG, Abraham TJ, Prudhoe C, Zhang Y, Scammells PJ, Brosseau CL, Pye CC, Singer RD. Electrochemical surface-enhanced Raman spectroscopy (E-SERS) of novel biodegradable ionic liquids. Phys Chem Chem Phys 2013; 15:19205-12. [DOI: 10.1039/c3cp52916a] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
|
12 |
21 |
23
|
Alfalou A, Brosseau C, Abdallah N, Jridi M. Simultaneous fusion, compression, and encryption of multiple images. OPTICS EXPRESS 2011; 19:24023-24029. [PMID: 22109426 DOI: 10.1364/oe.19.024023] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
We report a new spectral multiple image fusion analysis based on the discrete cosine transform (DCT) and a specific spectral filtering method. In order to decrease the size of the multiplexed file, we suggest a procedure of compression which is based on an adapted spectral quantization. Each frequency is encoded with an optimized number of bits according its importance and its position in the DC domain. This fusion and compression scheme constitutes a first level of encryption. A supplementary level of encryption is realized by making use of biometric information. We consider several implementations of this analysis by experimenting with sequences of gray scale images. To quantify the performance of our method we calculate the MSE (mean squared error) and the PSNR (peak signal to noise ratio). Our results consistently improve performances compared to the well-known JPEG image compression standard and provide a viable solution for simultaneous compression and encryption of multiple images.
Collapse
|
|
14 |
21 |
24
|
Bindesri SD, Jebailey R, Albarghouthi N, Pye CC, Brosseau CL. Spectroelectrochemical and computational studies of tetrahydrocannabinol (THC) and carboxy-tetrahydrocannabinol (THC-COOH). Analyst 2020; 145:1849-1857. [DOI: 10.1039/c9an02173f] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Electrochemical SERS allows for the rapid detection of both THC and THC-COOH in bodily fluid matrices without interferences from matrix species, paving the way to a point-of-need tool for cannabinoid detection.
Collapse
|
|
5 |
19 |
25
|
Wright JE, Fatih K, Brosseau CL, Omanovic S, Roscoe SG. l-Phenylalanine adsorption on Pt: electrochemical impedance spectroscopy and quartz crystal nanobalance studies. J Electroanal Chem (Lausanne) 2003. [DOI: 10.1016/s0022-0728(03)00026-3] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
|
22 |
15 |