1
|
Impact of Vaccination Status on Outcome of Patients With COVID-19 and Acute Ischemic Stroke Undergoing Mechanical Thrombectomy. J Am Heart Assoc 2024; 13:e031816. [PMID: 38639365 DOI: 10.1161/jaha.123.031816] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Accepted: 03/18/2024] [Indexed: 04/20/2024]
Abstract
BACKGROUND Data on impact of COVID-19 vaccination and outcomes of patients with COVID-19 and acute ischemic stroke undergoing mechanical thrombectomy are scarce. Addressing this subject, we report our multicenter experience. METHODS AND RESULTS This was a retrospective analysis of patients with COVID-19 and known vaccination status treated with mechanical thrombectomy for acute ischemic stroke at 20 tertiary care centers between January 2020 and January 2023. Baseline demographics, angiographic outcome, and clinical outcome evaluated by the modified Rankin Scale score at discharge were noted. A multivariate analysis was conducted to test whether these variables were associated with an unfavorable outcome, defined as modified Rankin Scale score >3. A total of 137 patients with acute ischemic stroke (48 vaccinated and 89 unvaccinated) with acute or subsided COVID-19 infection who underwent mechanical thrombectomy attributable to vessel occlusion were included in the study. Angiographic outcomes between vaccinated and unvaccinated patients were similar (modified Thrombolysis in Cerebral Infarction ≥2b: 85.4% in vaccinated patients versus 86.5% in unvaccinated patients; P=0.859). The rate of functional independence (modified Rankin Scale score, ≤2) was 23.3% in the vaccinated group and 20.9% in the unvaccinated group (P=0.763). The mortality rate was 30% in both groups. In the multivariable analysis, vaccination status was not a significant predictor for an unfavorable outcome (P=0.957). However, acute COVID-19 infection remained significant (odds ratio, 1.197 [95% CI, 1.007-1.417]; P=0.041). CONCLUSIONS Our study demonstrated no impact of COVID-19 vaccination on angiographic or clinical outcome of COVID-19-positive patients with acute ischemic stroke undergoing mechanical thrombectomy, whereas worsening attributable to COVID-19 was confirmed.
Collapse
|
2
|
Myocardial tissue changes detected by cardiac MRI in a patient with suspected systemic sarcoidosis. BMC Cardiovasc Disord 2023; 23:131. [PMID: 36906545 PMCID: PMC10007775 DOI: 10.1186/s12872-023-03133-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Accepted: 02/19/2023] [Indexed: 03/13/2023] Open
Abstract
BACKGROUND The role of cardiac magnetic resonance imaging in the early management of chronic cardiac inflammatory conditions is growing. Our case enlightens the benefit of quantitative mapping in the monitoring and treatment guidance in systemic sarcoidosis. CASE PRESENTATION We report about a 29-year-old man with an ongoing dyspnea and bihilar lymphadenopathy, suggesting sarcoidosis. Cardiac magnetic resonance showed high mapping values, but no scarring. In follow-ups, cardiac remodeling was noted; cardioprotective treatment normalized cardiac function and mapping markers. Definitive diagnosis was achieved in extracardiac lymphatic tissue during a relapse. CONCLUSION This case shows the role that mapping markers can play in the detection and treatment at early stage of systemic sarcoidosis.
Collapse
|
3
|
Human prion diseases and the prion protein - what is the current state of knowledge? Transl Neurosci 2023; 14:20220315. [PMID: 37854584 PMCID: PMC10579786 DOI: 10.1515/tnsci-2022-0315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Revised: 09/07/2023] [Accepted: 09/15/2023] [Indexed: 10/20/2023] Open
Abstract
Prion diseases and the prion protein are only partially understood so far in many aspects. This explains the continued research on this topic, calling for an overview on the current state of knowledge. The main objective of the present review article is to provide a comprehensive up-to-date presentation of all major features of human prion diseases bridging the gap between basic research and clinical aspects. Starting with the prion protein, current insights concerning its physiological functions and the process of pathological conversion will be highlighted. Diagnostic, molecular, and clinical aspects of all human prion diseases will be discussed, including information concerning rare diseases like prion-associated amyloidoses and Huntington disease-like 1, as well as the question about a potential human threat due to the transmission of prions from prion diseases of other species such as chronic wasting disease. Finally, recent attempts to develop future therapeutic strategies will be addressed.
Collapse
|
4
|
Head and neck single- and dual-energy CT: differences in radiation dose and image quality of 2nd and 3rd generation dual-source CT. Br J Radiol 2021; 94:20210069. [PMID: 33914613 PMCID: PMC8173672 DOI: 10.1259/bjr.20210069] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
OBJECTIVES To compare radiation dose and image quality of single-energy (SECT) and dual-energy (DECT) head and neck CT examinations performed with second- and third-generation dual-source CT (DSCT) in matched patient cohorts. METHODS 200 patients (mean age 55.1 ± 16.9 years) who underwent venous phase head and neck CT with a vendor-preset protocol were retrospectively divided into four equal groups (n = 50) matched by gender and BMI: second (Group A, SECT, 100-kV; Group B, DECT, 80/Sn140-kV), and third-generation DSCT (Group C, SECT, 100-kV; Group D, DECT, 90/Sn150-kV). Assessment of radiation dose was performed for an average scan length of 27 cm. Contrast-to-noise ratio measurements and dose-independent figure-of-merit calculations of the submandibular gland, thyroid, internal jugular vein, and common carotid artery were analyzed quantitatively. Qualitative image parameters were evaluated regarding overall image quality, artifacts and reader confidence using 5-point Likert scales. RESULTS Effective radiation dose (ED) was not significantly different between SECT and DECT acquisition for each scanner generation (p = 0.10). Significantly lower effective radiation dose (p < 0.01) values were observed for third-generation DSCT groups C (1.1 ± 0.2 mSv) and D (1.0 ± 0.3 mSv) compared to second-generation DSCT groups A (1.8 ± 0.1 mSv) and B (1.6 ± 0.2 mSv). Figure-of-merit/contrast-to-noise ratio analysis revealed superior results for third-generation DECT Group D compared to all other groups. Qualitative image parameters showed non-significant differences between all groups (p > 0.06). CONCLUSION Contrast-enhanced head and neck DECT can be performed with second- and third-generation DSCT systems without radiation penalty or impaired image quality compared with SECT, while third-generation DSCT is the most dose efficient acquisition method. ADVANCES IN KNOWLEDGE Differences in radiation dose between SECT and DECT of the dose-vulnerable head and neck region using DSCT systems have not been evaluated so far. Therefore, this study directly compares radiation dose and image quality of standard SECT and DECT protocols of second- and third-generation DSCT platforms.
Collapse
|
5
|
Can Dual-energy CT-based Virtual Monoenergetic Imaging Improve the Assessment of Hypodense Liver Metastases in Patients With Hepatic Steatosis? Acad Radiol 2021; 28:769-777. [PMID: 32446765 DOI: 10.1016/j.acra.2020.03.044] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Revised: 03/14/2020] [Accepted: 03/24/2020] [Indexed: 02/06/2023]
Abstract
RATIONALE AND OBJECTIVES To evaluate the impact of noise-optimized virtual monoenergetic imaging (VMI) on lesion demarcation and measuring accuracy of hypoattenuating liver metastases in patients with fatty liver disease compared to standard reconstructions. MATERIALS AND METHODS Twenty-eight patients (mean age 62.2 ± 7.7 years) with fatty liver disease and hypoattenuating liver metastases who underwent unenhanced and contrast-enhanced portal-venous dual-energy CT (DECT) were enrolled. Standard linearly blended and VMI series were reconstructed in 10-keV intervals. Lesion-to-parenchyma contrast-to-noise ratio (CNR) was calculated and the best VMI series was further investigated in a subjective evaluation of overall image quality and lesion demarcation. Size measurements were performed independently by measuring all hypodense lesions (n = 58) twice in a predefined sequence. Inter- and intra-rater agreement was assessed using intra-class correlation coefficient (ICC) statistics. RESULTS The calculated CNR was greatest at 40-keV VMI (4.3 ± 2.6), significantly higher compared to standard reconstructions (2.9 ± 1.9; p < 0.001). Subjective ratings for overall image quality showed no significant difference between the 2 reconstruction techniques (both medians 4; p = 0.147), while lesion margin demarcation was found to be superior for 40-keV VMI (median 5; p ≤ 0.001). Inter- (ICC, 0.98 for 40-keV VMI; ICC, 0.93 for standard reconstruction) and intra-rater (ICC, 0.99 for 40-keV VMI; ICC, 0.94 for standard image series) analysis showed an excellent agreement for lesion measurements in both reconstruction techniques. CONCLUSION Noise-optimized VMI reconstructions significantly improve contrast and lesion demarcation of hypoattenuating liver metastases in patients with the fatty liver disease compared to standard reconstruction.
Collapse
|
6
|
Prevalence and prognostic impact of nonischemic late gadolinium enhancement in stress cardiac magnetic resonance. J Cardiovasc Med (Hagerstown) 2021; 21:980-985. [PMID: 33156590 DOI: 10.2459/jcm.0000000000001016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
AIM To assess the prevalence and prognostic significance of NI-LGE in patients undergoing stress-CMR. METHODS Stress-CMR with either dipyridamole or adenosine was performed in 283 patients (228 men, 81%) including perfusion imaging, wall motion evaluation and LGE. Follow-up was completed in all enrolled patients (median time: 1850 days; interquartile range: 1225-2705 days). Composite endpoint included cardiac death, ventricular tachycardia, myocardial infarction, stroke, hospitalization for cardiac cause and coronary revascularization performed beyond 90 days from stress-CMR scans. RESULTS One hundred and twelve patients (40%) had negative LGE (no-LGE), 140 patients (49%) I-LGE and 31 patients (11%) NI-LGE. Twenty-five events occurred in the no-LGE group, 68 in I-LGE and 11 in the NI-LGE group. On survival curves, patients with NI-LGE had worse prognosis than patients with no-LGE regardless of the presence of inducible perfusion defects. No significant prognostic differences were found between I-LGE and NI-LGE. CONCLUSION NI-LGE can be detected in 11% of patients during stress-CMR providing a diagnosis of nonischemic cardiac disease. Patients with NI-LGE have worse prognosis than those with no-LGE.
Collapse
|
7
|
Myocardial Fibrosis and Inflammation by CMR Predict Cardiovascular Outcome in People Living With HIV. JACC Cardiovasc Imaging 2021; 14:1548-1557. [PMID: 33865770 DOI: 10.1016/j.jcmg.2021.01.042] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Revised: 12/30/2020] [Accepted: 01/28/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVES The goal of this study was to examine prognostic relationships between cardiac imaging measures and cardiovascular outcome in people living with human immunodeficiency virus (HIV) (PLWH) on highly active antiretroviral therapy (HAART). BACKGROUND PLWH have a higher prevalence of cardiovascular disease and heart failure (HF) compared with the noninfected population. The pathophysiological drivers of myocardial dysfunction and worse cardiovascular outcome in HIV remain poorly understood. METHODS This prospective observational longitudinal study included consecutive PLWH on long-term HAART undergoing cardiac magnetic resonance (CMR) examination for assessment of myocardial volumes and function, T1 and T2 mapping, perfusion, and scar. Time-to-event analysis was performed from the index CMR examination to the first single event per patient. The primary endpoint was an adjudicated adverse cardiovascular event (cardiovascular mortality, nonfatal acute coronary syndrome, an appropriate device discharge, or a documented HF hospitalization). RESULTS A total of 156 participants (62% male; age [median, interquartile range]: 50 years [42 to 57 years]) were included. During a median follow-up of 13 months (9 to 19 months), 24 events were observed (4 HF deaths, 1 sudden cardiac death, 2 nonfatal acute myocardial infarction, 1 appropriate device discharge, and 16 HF hospitalizations). Patients with events had higher native T1 (median [interquartile range]: 1,149 ms [1,115 to 1,163 ms] vs. 1,110 ms [1,075 to 1,138 ms]); native T2 (40 ms [38 to 41 ms] vs. 37 ms [36 to 39 ms]); left ventricular (LV) mass index (65 g/m2 [49 to 77 g/m2] vs. 57 g/m2 [49 to 64 g/m2]), and N-terminal pro-B-type natriuretic peptide (109 pg/l [25 to 337 pg/l] vs. 48 pg/l [23 to 82 pg/l]) (all p < 0.05). In multivariable analyses, native T1 was independently predictive of adverse events (chi-square test, 15.9; p < 0.001; native T1 [10 ms] hazard ratio [95% confidence interval]: 1.20 [1.08 to 1.33]; p = 0.001), followed by a model that also included LV mass (chi-square test, 17.1; p < 0.001). Traditional cardiovascular risk scores were not predictive of the adverse events. CONCLUSIONS Our findings reveal important prognostic associations of diffuse myocardial fibrosis and LV remodeling in PLWH. These results may support development of personalized approaches to screening and early intervention to reduce the burden of HF in PLWH (International T1 Multicenter Outcome Study; NCT03749343).
Collapse
|
8
|
Comparison of contrast-enhanced videofluoroscopy to unenhanced dynamic MRI in minor patients following surgical correction of velopharyngeal dysfunction. Eur Radiol 2020; 31:76-84. [PMID: 32740819 DOI: 10.1007/s00330-020-07098-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Revised: 06/02/2020] [Accepted: 07/21/2020] [Indexed: 11/26/2022]
Abstract
OBJECTIVES To compare dynamic magnetic resonance imaging (MRI) with videofluoroscopy (VFS) regarding image quality and assessment of gap size between soft palate (SP) and posterior pharyngeal wall (PPW) in children and adolescents following surgical correction of velopharyngeal dysfunction (VPD). METHODS Twenty-one patients undergoing unenhanced 3-T MRI and contrast-enhanced VFS were included in this IRB-approved prospective study. The MRI scan protocol comprised refocused gradient-echo sequences in transverse and sagittal planes during speech, with TE 1.97 ms, TR 3.95 ms, flip angle 8°, matrix size 128 × 128, and 5-mm slice thickness. Radial k-space sampling and sliding window reconstruction were used to achieve an image acquisition rate of 28 frames per second (fps). VFS with 30 fps was similarly performed in both planes. Closure of the velopharyngeal port during phonation was evaluated by two experienced radiologists. RESULTS Eleven (52.4%) patients displayed a complete closure, whereas ten (47.6%) patients showed a post-operative gap during speech. VFS and MRI equally identified the cases with persistent or recurrent VPD. Differences in SP-PPW distance between VFS (3.9 ± 1.6 mm) and MRI (4.1 ± 1.5 mm) were not statistically significant (p = 0.5). The subjective overall image quality of MRI was rated inferior (p < 0.001) compared with VFS, with almost perfect inter-rater agreement (κ = 0.90). The presence of susceptibility artifacts did not limit anatomical measurements. CONCLUSION Dynamic MRI is equally reliable as VFS to assess persistent or recurrent inadequate velum closure in patients following surgical treatment of VPD. KEY POINTS • Unenhanced 3-T dynamic MRI and contrast-enhanced videofluoroscopy are equally useful for the identification of patients with incomplete velopharyngeal closure during speech. • MRI using refocused gradient-echo acquisition with radial k-space sampling and sliding window reconstruction generates diagnostic images with 28 frames per second. • MRI can offer a radiation-free alternative to currently established videofluoroscopy for young patients.
Collapse
|
9
|
Carotid and cerebrovascular dual-energy computed tomography angiography: Optimization of window settings for virtual monoenergetic imaging reconstruction. Eur J Radiol 2020; 130:109166. [PMID: 32693314 DOI: 10.1016/j.ejrad.2020.109166] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2019] [Revised: 04/25/2020] [Accepted: 07/05/2020] [Indexed: 02/08/2023]
Abstract
PURPOSE Dedicated post-processing of dual-energy computed tomography angiography (DE-CTA) datasets has been shown to allow for increased vascular contrast. The goal of our study was to define optimal window settings for displaying virtual monoenergetic images (VMI) reconstructed from dual-energy carotid and cerebrovascular DE-CTA. METHODS Fifty-seven patients who underwent clinically-indicated carotid and cerebrovascular third-generation dual-source DE-CTA were retrospectively evaluated. Standard linearly-blended (M_0.6), 70-keV traditional VMI (M70), and 40-keV noise-optimized VMI (M40+) reconstructions were analyzed. For M70 and M40+ datasets, the subjectively best window setting (width and level, B-W/L) was independently determined by two observers and subsequently related with aortic arch attenuation to calculate optimized values (O-W/L) using linear regression. Subjective evaluation of image quality (IQ) between W/L settings were assessed by two additional readers. Repeated measures analysis of variance were performed to compare W/L settings and IQ indices between M_0.6, M70, and M40 + . RESULTS B-W/L and O-W/L for M70 were 580/210 and 560/200, and for M40+ were 1630/570 and 1560/550, respectively, higher than standard DE-CTA W/L settings (450/100). Highest subjective scores were observed for M40+ regarding overall IQ (all p < 0.001). CONCLUSION Application of O-W/L settings is mandatory to optimize subjective IQ of VMI reconstructions of DE-CTA.
Collapse
|
10
|
Erratum to: After ISCHEMIA: Is cardiac MRI a reliable gatekeeper for invasive angiography and myocardial revascularization? Herz 2020; 45:505. [PMID: 32613316 DOI: 10.1007/s00059-020-04963-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
In the above mentioned article, the family name of the second author was not given correctly: it is Carerj instead of Careri.The authors apologize for this mistake.The original article has been ….
Collapse
|
11
|
Measurement Reliability and Diagnostic Accuracy of Virtual Monoenergetic Dual-Energy CT in Patients with Colorectal Liver Metastases. Acad Radiol 2020; 27:e168-e175. [PMID: 31727567 DOI: 10.1016/j.acra.2019.09.020] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2019] [Revised: 09/04/2019] [Accepted: 09/12/2019] [Indexed: 12/12/2022]
Abstract
RATIONALE AND OBJECTIVES To compare dual-energy CT virtual monoenergetic images (VMI) and standard reconstructions for reliability of quantitative size measurements and diagnostic accuracy for the detection of colorectal liver metastases (CRLM). MATERIALS AND METHODS We retrospectively included 98 patients (mean age, 61.1±11.5 years) with colorectal cancer, of whom 49 subjects had CRLM. All patients underwent a portal-venous phase dual-energy CT examination. Standard linearly-blended reformats and 40-keV VMI were reconstructed. For both reconstruction techniques, two blinded readers performed measurements of CRLM twice in a preset sequence. Three additional radiologists independently assessed all liver lesions in terms of dignity (benign vs. malignant). Sensitivity, specificity and diagnostic accuracy were calculated on a per-patient basis using MRI as reference standard. Readers scored the suitability for metric measurements and their diagnostic confidence using 5-point Likert scales. Inter-rater agreement was evaluated using intraclass correlation coefficient (ICC). RESULTS Inter-rater agreement for lesion size measurements was higher for 40-keV VMI (ICC, 0.88) compared to standard linearly-blended series (ICC, 0.80). Sensitivity and diagnostic accuracy for the detection of CRLM were significantly higher for VMI at 40-keV compared to standard reconstructions (90.6% vs. 80.6%, and 89.1% vs. 81.3%; p < 0.001). Reader scores indicated that 40-keV VMI were more suitable for metric lesion measurements and provided greater diagnostic confidence compared to standard reformats (median, 5 vs. 3, and 5 vs. 4; both p < 0.001). CONCLUSION Low-keV VMI reconstructions improve reliability of quantitative size measurements and diagnostic accuracy for the assessment of CRLM compared to standard linearly-blended images.
Collapse
|
12
|
Improved coronary artery contrast enhancement using noise-optimised virtual monoenergetic imaging from dual-source dual-energy computed tomography. Eur J Radiol 2019; 122:108666. [PMID: 31786506 DOI: 10.1016/j.ejrad.2019.108666] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2019] [Revised: 09/04/2019] [Accepted: 09/12/2019] [Indexed: 01/15/2023]
Abstract
PURPOSE To define optimal kiloelectron volt (keV) settings for virtual monoenergetic imaging (VMI) reconstruction at dual-energy coronary computed tomography angiography (DE-CCTA). METHOD Fifty-one DE-CCTA data sets (33 men; mean age, 63.9 ± 13.2 years) were reconstructed as standard linearly-blended images (F_0.6; 60% of 90 kVp, 40% of 150 kVpSn), and with traditional (VMI) and noise-optimised (VMI+) algorithms from 40 to 100 keV in 10-keV intervals. Objective image quality was assessed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements. Three observers subjectively evaluated vascular contrast, image sharpness, noise and delineation of coronary plaques. RESULTS Median values for objective image analysis were highest in VMI + series at 40 keV (SNR, 44.5; CNR: 33.5), significantly superior (allp < 0.001) to the best VMI series at 70 keV (SNR, 28.1; CNR, 18.4) and standard F_0.6 images (SNR, 23.2; CNR, 15.6). Overall subjective metrics achieved higher scores at 40-keV VMI+ series in comparison to 70-keV VMI series and F_0.6 images (all p < 0.001), with optimal vascular contrast (5; ICC, 0.90), good image sharpness (4; 0.88), low noise (4; 0.82), and optimal plaque delineation (5; 0.89). CONCLUSIONS DE-CCTA image reconstruction with 40-keV VMI + allows for significant improvement of both objective and subjective image quality.
Collapse
|
13
|
Gadolinium-enhanced imaging of pediatric thoracic lymphoma: is intravenous contrast really necessary? Eur Radiol 2018; 29:2553-2559. [PMID: 30547199 DOI: 10.1007/s00330-018-5859-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Revised: 09/27/2018] [Accepted: 10/25/2018] [Indexed: 01/15/2023]
Abstract
OBJECTIVES Increasing awareness of potential side effects from gadolinium-based contrast agents has underlined the need for contrast-free magnetic resonance imaging (MRI). Numerous recent articles evaluated the risk of potential brain deposits, with the result that research is putting the focus more on alternative unenhanced imaging techniques. The aim of this study was to determine the need for contrast media for chest MRI in primary staging and follow-up care of lymphoma. METHODS This monocentric, retrospective study encompassed patients under 25 years of age who had undergone histopathological examination of thoracic lymph nodes and at least one chest MRI examination with unenhanced and contrast-enhanced sequences. Seven different thoracic lymph node stations including mediastinal, hilar, periclavicular, and axillary regions were evaluated by two readers regarding lesion diameter, number, shape, necrosis, and infiltration of surrounding structures. Findings were categorized into suspicious (> 1 cm; round; necrosis; infiltration) or non-suspicious. RESULTS Fifty-one patients (mean age, 16.0 ± 3.7 yrs) with thoracic Hodgkin (70.6%) and non-Hodgkin lymphoma (25.5%) and lymphadenopathy (3.9%) were retrospectively included. Most lymph nodes categorized as suspicious were located in the mediastinal station (86.4%). High agreement (κ = 0.81) between unenhanced and contrast-enhanced sequences was found for both suspicious and non-suspicious lymph nodes. Significant (p < 0.001), but small difference (1 mm) was observed only in sizing mediastinal lymph nodes (all other p > 0.05). No significant difference (smallest p = 0.08) was shown for the use of five different types of contrast media. CONCLUSION MRI in young patients with thoracic lymphoma can safely be done without the use of contrast agent. KEY POINT • Thoracic magnetic resonance imaging in young lymphoma patients can safely be done without gadolinium-based contrast agents.
Collapse
|
14
|
Multi-observer comparison study between unenhanced quiescent-interval single-shot magnetic resonance angiography and invasive carbon dioxide angiography in patients with peripheral arterial disease and chronic renal insufficiency. Eur J Radiol 2018; 108:140-146. [DOI: 10.1016/j.ejrad.2018.09.029] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2018] [Revised: 08/06/2018] [Accepted: 09/25/2018] [Indexed: 11/29/2022]
|
15
|
Dual-energy CT in patients with abdominal malignant lymphoma: impact of noise-optimised virtual monoenergetic imaging on objective and subjective image quality. Clin Radiol 2018; 73:833.e19-833.e27. [PMID: 29884524 DOI: 10.1016/j.crad.2018.04.015] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2017] [Accepted: 04/25/2018] [Indexed: 12/12/2022]
Abstract
AIM To investigate the impact of noise-optimised virtual monoenergetic imaging (VMI+) reconstructions on quantitative and qualitative image parameters in patients with malignant lymphoma at dual-energy computed tomography (DECT) examinations of the abdomen. MATERIALS AND METHODS Thirty-five consecutive patients (mean age, 53.8±18.6 years; range, 21-82 years) with histologically proven malignant lymphoma of the abdomen were included retrospectively. Images were post-processed with standard linear blending (M_0.6), traditional VMI, and VMI+ technique at energy levels ranging from 40 to 100 keV in 10 keV increments. Signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were objectively measured in lymphoma lesions. Image quality, lesion delineation, and image noise were rated subjectively by three blinded observers using five-point Likert scales. RESULTS Quantitative image quality parameters peaked at 40-keV VMI+ (SNR, 15.77±7.74; CNR, 18.27±8.04) with significant differences compared to standard linearly blended M_0.6 (SNR, 7.96±3.26; CNR, 13.55±3.47) and all traditional VMI series (p<0.001). Qualitative image quality assessment revealed significantly superior ratings for image quality at 60-keV VMI+ (median, 5) in comparison with all other image series (p<0.001). Assessment of lesion delineation showed the highest rating scores for 40-keV VMI+ series (median, 5), while lowest subjective image noise was found for 100-keV VMI+ reconstructions (median, 5). CONCLUSION Low-keV VMI+ reconstructions led to improved image quality and lesion delineation of malignant lymphoma lesions compared to standard image reconstruction and traditional VMI at abdominal DECT examinations.
Collapse
|
16
|
Impact of T-cell-mediated immune response on xenogeneic heart valve transplantation: short-term success and mid-term failure. Eur J Cardiothorac Surg 2018; 53:784-792. [PMID: 29186380 DOI: 10.1093/ejcts/ezx396] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2017] [Accepted: 10/23/2017] [Indexed: 11/12/2022] Open
Abstract
OBJECTIVES Allogeneic frozen cryopreserved heart valves (allografts or homografts) are commonly used in clinical practice. A major obstacle for their application is the limited availability in particular for paediatrics. Allogeneic large animal studies revealed that alternative ice-free cryopreservation (IFC) results in better matrix preservation and reduced immunogenicity. The objective of this study was to evaluate xenogeneic (porcine) compared with allogeneic (ovine) IFC heart valves in a large animal study. METHODS IFC xenografts and allografts were transplanted in 12 juvenile merino sheep for 1-12 weeks. Immunohistochemistry, ex vivo computed tomography scans and transforming growth factor-β release profiles were analysed to evaluate postimplantation immunopathology. In addition, near-infrared multiphoton imaging and Raman spectroscopy were employed to evaluate matrix integrity of the leaflets. RESULTS Acellular leaflets were observed in both groups 1 week after implantation. Allogeneic leaflets remained acellular throughout the entire study. In contrast, xenogeneic valves were infiltrated with abundant T-cells and severely thickened over time. No collagen or elastin changes could be detected in either group using multiphoton imaging. Raman spectroscopy with principal component analysis focusing on matrix-specific peaks confirmed no significant differences for explanted allografts. However, xenografts demonstrated clear matrix changes, enabling detection of distinct inflammatory-driven changes but without variations in the level of transforming growth factor-β. CONCLUSIONS Despite short-term success, mid-term failure of xenogeneic IFC grafts due to a T-cell-mediated extracellular matrix-triggered immune response was shown.
Collapse
|
17
|
Using coronary CT angiography for guiding invasive coronary angiography: potential role to reduce intraprocedural radiation exposure. Eur Radiol 2018; 28:2756-2762. [PMID: 29417250 DOI: 10.1007/s00330-018-5317-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2017] [Revised: 12/29/2017] [Accepted: 01/09/2018] [Indexed: 10/18/2022]
Abstract
OBJECTIVES We investigated the potential reduction of patient exposure during invasive coronary angiography (ICA) if the procedure had only been directed to the vessel with at least one ≥ 50% stenosis as described in the CT report. METHODS Dose reports of 61 patients referred to ICA because of at least one ≥ 50% stenosis on coronary CT angiography (CCTA) were included. Dose-area product (DAP) was documented separately for left (LCA) and right coronary arteries (RCA) by summing up the single DAP for each angiographic projection. The study population was subdivided as follows: coronary intervention of LCA (group 1) or RCA (group 2) only, or of both vessels (group 3), or further bypass grafting (group 4), or no further intervention (group 5). RESULTS 57.4% of the study population could have benefitted from reduced exposure if catheterization had been directly guided to the vessel of interest as described on CCTA. Mean relative DAP reductions were as follows: group 1 (n = 18), 11.2%; group 2 (n = 2), 40.3%; group 3 (n = 10), 0%; group 4 (n = 3), 0%; group 5 (n = 28), 28.8%. CONCLUSIONS Directing ICA to the vessel with stenosis as described on CCTA would reduce intraprocedural patient exposure substantially, especially for patients with single-vessel stenosis. KEY POINTS • Patients with CAD can benefit from decreased radiation exposure during coronary angiography. • ICA should be directed solely to significant stenoses as described on CCTA. • Severely calcified plaques remain a limitation of CCTA leading to unnecessary ICA referrals.
Collapse
|
18
|
Evaluation of virtual monoenergetic imaging algorithms for dual-energy carotid and intracerebral CT angiography: Effects on image quality, artefacts and diagnostic performance for the detection of stenosis. Eur J Radiol 2018; 99:111-117. [DOI: 10.1016/j.ejrad.2017.12.024] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2017] [Revised: 12/01/2017] [Accepted: 12/29/2017] [Indexed: 10/18/2022]
|
19
|
Optimisation of window settings for traditional and noise-optimised virtual monoenergetic imaging in dual-energy computed tomography pulmonary angiography. Eur Radiol 2017; 28:1393-1401. [DOI: 10.1007/s00330-017-5059-6] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2017] [Revised: 08/16/2017] [Accepted: 09/05/2017] [Indexed: 12/30/2022]
|