1
|
Effect of fructooligosaccharide on endothelial function in CKD patients: a randomized controlled trial. Nephrol Dial Transplant 2021; 37:85-91. [PMID: 33411910 DOI: 10.1093/ndt/gfaa335] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND Microbiota-derived uremic toxins have been associated with inflammation that could corroborate with endothelial dysfunction (ED) and increase cardiovascular risk in patients with chronic kidney disease (CKD). This trial aimed to evaluate the effect of the prebiotic fructooligosaccharide (FOS) on endothelial function and arterial stiffness in nondialysis CKD patients. METHODS In a double-blind controlled trial, 46 nondiabetic CKD patients were randomized to receive 12 g/day of FOS or placebo (maltodextrin) for 3 months. Total p-cresyl sulfate (PCS) and indoxyl sulfate by high-performance liquid chromatography, urinary trimethylamine N-oxide by mass spectrometry, C-reactive protein, interleukin-6 (IL-6), serum nitric oxide and stroma-derived factor-1 alfa were measured at baseline and at the end of follow-up; endothelial function was assessed through flow-mediated dilatation (FMD) and arterial stiffness by pulse wave velocity (PWV). RESULTS The mean (± standard deviation) age of the study participants was 57.6 ± 14.4 years, with an estimated glomerular filtration rate of 21.3 ± 7.3 mL/min/1.73 m2. During the follow-up, regarding the inflammatory markers and uremic toxins, there was a significant decrease in IL-6 levels (3.4 ± 2.1 pg/mL versus 2.6 ± 1.4 pg/mL; P = 0.04) and a trend toward PCS reduction (55.4 ± 38.1 mg/L versus 43.1 ± 32.4 mg/L, P = 0.07) only in the prebiotic group. Comparing both groups, there was no difference in FMD and PWV. In an exploratory analysis, including a less severe ED group of patients (FMD ≥2.2% at baseline), FMD remained stable in the prebiotic group, while it decreased in the placebo group (group effect P = 0.135; time effect P = 0.012; interaction P = 0.002). CONCLUSIONS The prebiotic FOS lowered circulating levels of IL-6 in CKD patients and preserved endothelial function only in those with less damaged endothelium. No effect of FOS in arterial stiffness was observed.
Collapse
|
2
|
Separation of carbohydrates on electrophoresis microchips with controlled electrolysis. Electrophoresis 2019; 40:693-698. [DOI: 10.1002/elps.201800354] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Revised: 12/17/2018] [Accepted: 12/18/2018] [Indexed: 01/05/2023]
|
3
|
Phytochemical characterization of the Vochysia rufa (Vochysiaceae) extract and its effects on oxidative stress in the pancreata of streptozotocin-induced diabetic rats. PLoS One 2017; 12:e0184807. [PMID: 28981518 PMCID: PMC5628804 DOI: 10.1371/journal.pone.0184807] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2016] [Accepted: 08/31/2017] [Indexed: 11/18/2022] Open
Abstract
Aqueous extract of macerated Vochysia rufa stem bark has been commonly used in the treatment of diabetes. Therefore, we evaluated the antihyperglycemic and antioxidant effects of an extract of V. rufa on the pancreata of streptozotocin (STZ)-induced diabetic rats. Animals received one of the following treatments daily by oral gavage: water (diabetic-control), V. rufa extract (diabetic-V. rufa), or glibenclamide (diabetic-GBD). Total antioxidant capacity; levels of thiobarbituric acid reactive substances, reduced glutathione, and sulfhydryls; and superoxide dismutase, catalase, and glutathione peroxidase (GPx) activities were measured in the pancreas. Biochemical analysis of serum total cholesterol and fractions, triglycerides, creatinine, urea, acid uric, ALP, γ-GT, AST, and ALT was performed, and pancreatic β-cells positive for insulin were evaluated by immunohistochemistry. Rats treated with extract exhibited a decrease in fasting blood glucose compared with levels in diabetic control rats. GPx activity and sulfhydryl levels were significantly lower in diabetic-V. rufa rats compared with those of diabetic-control rats. V. rufa extract acted to normalize the biochemical alterations found in diabetic rats (diabetic-controls), as demonstrated by increases in urea, HDL, ALP, AST, and ALT. Reduction in blood glucose was independent of an increase in insulin. The V. rufa extract was found to be composed of free sugars (inositol, galactose, glucose, mannose, sucrose, arabinose, and ribose) as the main metabolites. Thus, aqueous extract of the stem bark of V. rufa is capable of reducing blood glucose, resulting in an antioxidant effect on the pancreatic tissue of STZ-diabetic rats.
Collapse
|
4
|
Determination of Inorganic Ion Profiles of Illicit Drugs by Capillary Electrophoresis. J Forensic Sci 2016; 61:1610-1614. [PMID: 27569250 DOI: 10.1111/1556-4029.13175] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2015] [Revised: 08/30/2015] [Accepted: 01/17/2016] [Indexed: 11/30/2022]
Abstract
A portable capillary electrophoresis instrument with dual capacitively coupled contactless conductivity detection (C4 D) was used to determine the inorganic ionic profiles of three pharmaceutical samples and precursors of two illicit drugs (contemporary samples of methylone and para-methoxymethamphetamine). The LODs ranged from 0.10 μmol/L to 1.25 μmol/L for the 10 selected cations, and from 0.13 μmol/L to 1.03 μmol/L for the eight selected anions. All separations were performed in less than 6 min with migration times and peak area RSD values ranging from 2 to 7%. The results demonstrate the potential of the analysis of inorganic ionic species to aid in the identification and/or differentiation of unknown tablets, and real samples found in illicit drug manufacture scenarios. From the resulting ionic fingerprint, the unknown tablets and samples can be further classified.
Collapse
|
5
|
Formation of isomers of anionic hemiesters of sugars and carbonic acid in aqueous medium. Carbohydr Res 2016; 428:18-22. [DOI: 10.1016/j.carres.2016.04.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2016] [Revised: 04/06/2016] [Accepted: 04/07/2016] [Indexed: 11/17/2022]
|
6
|
Fast production of microfluidic devices by CO2laser engraving of wax-coated glass slides. Electrophoresis 2016; 37:1691-5. [DOI: 10.1002/elps.201600065] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2016] [Revised: 03/04/2016] [Accepted: 03/16/2016] [Indexed: 12/11/2022]
|
7
|
Analysis ofEcstasyTablets Using Capillary Electrophoresis with Capacitively Coupled Contactless Conductivity Detection. J Forensic Sci 2014; 59:1622-6. [DOI: 10.1111/1556-4029.12573] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2013] [Revised: 11/15/2013] [Accepted: 12/01/2013] [Indexed: 12/30/2022]
|
8
|
Getting started with open-hardware: development and control of microfluidic devices. Electrophoresis 2014; 35:2370-7. [PMID: 24823494 DOI: 10.1002/elps.201400128] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2014] [Revised: 05/07/2014] [Accepted: 05/07/2014] [Indexed: 12/20/2022]
Abstract
Understanding basic concepts of electronics and computer programming allows researchers to get the most out of the equipment found in their laboratories. Although a number of platforms have been specifically designed for the general public and are supported by a vast array of on-line tutorials, this subject is not normally included in university chemistry curricula. Aiming to provide the basic concepts of hardware and software, this article is focused on the design and use of a simple module to control a series of PDMS-based valves. The module is based on a low-cost microprocessor (Teensy) and open-source software (Arduino). The microvalves were fabricated using thin sheets of PDMS and patterned using CO2 laser engraving, providing a simple and efficient way to fabricate devices without the traditional photolithographic process or facilities. Synchronization of valve control enabled the development of two simple devices to perform injection (1.6 ± 0.4 μL/stroke) and mixing of different solutions. Furthermore, a practical demonstration of the utility of this system for microscale chemical sample handling and analysis was achieved performing an on-chip acid-base titration, followed by conductivity detection with an open-source low-cost detection system. Overall, the system provided a very reproducible (98%) platform to perform fluid delivery at the microfluidic scale.
Collapse
|
9
|
Characterization of microchip electrophoresis devices fabricated by direct-printing process with colored toner. Electrophoresis 2013; 34:2169-76. [DOI: 10.1002/elps.201300024] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2013] [Revised: 03/04/2013] [Accepted: 04/02/2013] [Indexed: 11/12/2022]
|
10
|
Capillary electrophoresis with capacitively coupled contactless conductivity detection applied to the quantitation and to the determination of physical-chemical properties of peroxycarboxylates in aqueous medium. Electrophoresis 2013; 34:2065-71. [DOI: 10.1002/elps.201300059] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2013] [Revised: 02/25/2013] [Accepted: 03/09/2013] [Indexed: 11/07/2022]
|
11
|
Simultaneous determination of diclofenac and its common counter-ions in less than 1 minute using capillary electrophoresis with contactless conductivity detection. Electrophoresis 2013; 34:1423-8. [DOI: 10.1002/elps.201300008] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2012] [Revised: 02/06/2013] [Accepted: 02/20/2013] [Indexed: 11/07/2022]
|
12
|
On the formation of carbonate adducts of fatty alcohols, sterols, and sugars in biological conditions. Electrophoresis 2012; 33:2102-11. [DOI: 10.1002/elps.201200080] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
13
|
Environmental formaldehyde analysis by active diffusive sampling with a bundle of polypropylene porous capillaries followed by capillary zone electrophoretic separation and contactless conductivity detection. Talanta 2008; 76:271-5. [PMID: 18585276 DOI: 10.1016/j.talanta.2008.02.037] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2007] [Revised: 02/22/2008] [Accepted: 02/25/2008] [Indexed: 10/22/2022]
Abstract
Compared to other volatile carbonylic compounds present in outdoor air, formaldehyde (CH(2)O) is the most toxic, deserving more attention in terms of indoor and outdoor air quality legislation and control. The analytical determination of CH(2)O in air still presents challenges due to the low-level concentration (in the sub-ppb range) and its variation with sampling site and time. Of the many available analytical methods for carbonylic compounds, the most widespread one is the time consuming collection in cartridges impregnated with 2,4-dinitrophenylhydrazine followed by the analysis of the formed hydrazones by HPLC. The present work proposes the use of polypropylene hollow porous capillary fibers to achieve efficient CH(2)O collection. The Oxyphan fiber (designed for blood oxygenation) was chosen for this purpose because it presents good mechanical resistance, high density of very fine pores and high ratio of collection area to volume of the acceptor fluid in the tube, all favorable for the development of air sampling apparatus. The collector device consists of a Teflon pipe inside of which a bundle of polypropylene microporous capillary membranes was introduced. While the acceptor passes at a low flow rate through the capillaries, the sampled air circulates around the fibers, impelled by a low flow membrane pump (of the type used for aquariums ventilation). The coupling of this sampling technique with the selective and quantitative determination of CH(2)O, in the form of hydroxymethanesulfonate (HMS) after derivatization with HSO(3)(-), by capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C(4)D) enabled the development of a complete analytical protocol for the CH(2)O evaluation in air.
Collapse
|
14
|
Avaliação da composição química de águas do Sistema Guarapiranga: estudo de caso nos anos de 2002 e 2003. QUIM NOVA 2007. [DOI: 10.1590/s0100-40422007000500018] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
15
|
Retention of copper(II) metal ions in a silicon-glass microfluidic device. J BRAZIL CHEM SOC 2007. [DOI: 10.1590/s0103-50532007000800013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
16
|
Purification, characterization and molecular cloning of the major chitinase from Tenebrio molitor larval midgut. INSECT BIOCHEMISTRY AND MOLECULAR BIOLOGY 2006; 36:789-800. [PMID: 17027845 DOI: 10.1016/j.ibmb.2006.07.007] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2006] [Revised: 07/19/2006] [Accepted: 07/25/2006] [Indexed: 05/12/2023]
Abstract
Insect chitinases are involved in degradation of chitin from the exoskeleton cuticle or from midgut peritrophic membrane during molts. cDNAs coding for insect cuticular and gut chitinases were cloned, but only chitinases from moulting fluid were purified and characterized. In this study the major digestive chitinase from T. molitor midgut (TmChi) was purified to homogeneity, characterized and sequenced after cDNA cloning. TmChi is secreted by midgut epithelial cells, has a molecular weight of 44 kDa and is unstable in the presence of midgut proteinases. TmChi shows strong substrate inhibition when acting on umbelliferyl-derivatives of chitobio- and chitotriosaccharides, but has normal Michaelis kinetics with the N-acetylglucosamine derivative as substrate. TmChi has very low activity against colloidal chitin, but effectively converts oligosaccharides to shorter fragments. The best substrate for TmChi is chitopentaose, with highest k(cat)/K(M) value. Sequence analysis and chemical modification experiments showed that the TmChi active site contains carboxylic groups and a tryptophane, which are known to be important for catalysis in family 18 chitinases. Modification with p-hidroximercuribenzoate of a cysteine residue, which is exposed after substrate binding, leads to complete inactivation of the enzyme. TmChi mRNA encodes a signal peptide plus a protein with 37 kDa and high similarity with other insect chitinases from family 18. Surprisingly, this gene does not encode the C-terminal Ser-Thr-rich connector and chitin-binding domain normally present in chitinases. The special features of TmChi probably result from its adaptation to digest chitin-rich food without damaging the peritrophic membrane.
Collapse
|
17
|
Uso de frascos de polipropileno descartáveis no pré-tratamento de amostras de água para determinação de chumbo, cobre e mercúrio por voltametria de onda quadrada. QUIM NOVA 2006. [DOI: 10.1590/s0100-40422006000400039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
18
|
Determination of salbutamol in syrups by capillary electrophoresis with contactless conductivity detection (CE-C4D). J Pharm Biomed Anal 2006; 40:1288-92. [PMID: 16303274 DOI: 10.1016/j.jpba.2005.09.027] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2005] [Revised: 09/21/2005] [Accepted: 09/29/2005] [Indexed: 10/25/2022]
Abstract
This paper describes the separation and quantification of salbutamol in pharmaceutical products (salbutamol syrups) by capillary electrophoresis (CE) with contactless conductivity detection (C(4)D). The system was studied by micellar electrokinetic capillary chromatography (MEKC) and free solution capillary electrophoresis (FSCE), being the latter chosen in function of best resolution and sensitivity in comparison with the MEKC method. CE-C(4)D was applied to analysis of salbutamol in syrups utilizing 1.0 x 10(-2) molL(-1) acetic acid/sodium acetate buffer (pH 4.9) as running electrolyte. Tetraethylammonium (TEA) solution was used as internal standard. The results obtained include a linear dynamic range from 7. x 10(-5) to 3.0 x 10(-4) molL(-1) and good repeatability (R.S.D.=4.7% for n=10 for a 7.0 x 10(-5) molL(-1) salbutamol solution). The detection limit was calculated as 1.0 x 10(-5) molL(-1) and the limit of quantification was estimated as 3.3 x 10(-5) molL(-1). For syrups analysis the reproducibility presented deviations between 1.5% and 2.5% (three different days) obtained for measurements in triplicate.
Collapse
|
19
|
Determination of anions, cations, and sugars in coconut water by capillary electrophoresis. J BRAZIL CHEM SOC 2005. [DOI: 10.1590/s0103-50532005000700008] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
20
|
Abstract
We describe a simple and easy way to construct gold microelectrodes for amperometric detection in capillary electrophoresis (CE). The gold microelectrodes, in single or twin sets, were obtained from recordable compact discs (gold-sputtered type), which present highly reproducible surface characteristics. The performance of these electrodes was evaluated by using a home-made CE equipment. The basic steps for the electrode construction are: drawing on a microcomputer; laser printing of the design on wax paper; heat-transfer of the toner onto the gold surface of a peeled recordable compact disc (CD-R); etching of the gold layer from unprinted regions; removal of the toner with a solvent; sealing of unused electrode areas with varnish. One electrode at a time was connected to a potentiostat (or two, to a bipotentiostat) and operated in a wall jet configuration relative to the CE capillary outlet. The amperometric signals were integrated for quantification purposes. Repetitive injections (n = 10) of a mixture containing iodide, ascorbic acid, dipyrone, and acetaminophen (20, 200, 500, and 100 microM), presented relative standard deviations of 2.9, 4.5, 6.1, and 4.0%, respectively. For these analytes, the detection limits (S/N = 3, 30 s of 100 mm hydrodynamic injection) were 0.1, 0.5, 3.1, and 1.1 microM, respectively.
Collapse
|
21
|
Electrophoresis microchip fabricated by a direct-printing process with end-channel amperometric detection. Electrophoresis 2004; 25:3832-9. [PMID: 15565680 DOI: 10.1002/elps.200406091] [Citation(s) in RCA: 54] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
We describe the development of an electrophoresis microchip fabricated by a direct-printing process, based on lamination of printed polyester films with end-channel amperometric detection. The channel structures are defined by polyester (base and cover) and by a toner layer (walls). The polyester-toner devices presented an electroosmotic flow (EOF) magnitude of approximately 10(-5) cm2 V(-1) s(-1), which is generated by a polymeric mixture of the toner and polyester composition. The microelectrodes used for detection were produced combining this laser-printer technology to compact discs. The performance of this device was evaluated by amperometric detection of iodide and ascorbate. The detection limits found were 500 nmol.L(-1) (135 amol) and 1.8 micromol.L(-1) (486 amol) for iodide and ascorbate, respectively.
Collapse
|
22
|
Abstract
A new process for the manufacture of microfluidic devices based on deposition of laser-printing toner on glass substrates is described. It is an alternative method to the toner on polyester film (toner-polyester) one, previously introduced. Commercial laser printers cannot print directly on glass, thus the toner must first be printed on a special paper and then transferred by heating under pressure to the glass surface. Although this procedure is more complex than the toner-polyester one, it can be repeated several times, yielding multiple toner layers. Even without special alignment equipment, up to four layers could be satisfactorily piled up. Characterization tests revealed that the toner-glass devices have similar behavior as toner-polyester ones regarding the toner layer porosity. The main advantages of the toner-glass technology are improved mechanical stability, possibility of multiple toner layers, augmented electroosmotic flow (EOF), and improved heat transfer. On the other hand, toner adhesion to glass is weaker than to polyester, which limits the device lifetime and usable liquid media. The measured EOF mobility (3.5 x 10(-4) cm2.V(-1).s(-1) for pH 7) suggests that it is mainly determined by the glass surface, being little influenced by the toner walls. Microchip electrophoresis with contactless conductivity detection and photometric detection were implemented using toner-glass devices.
Collapse
|
23
|
Determination of boron in natural water and products derived from grape using an automated flow injection analysis system with piezoelectric detection. J BRAZIL CHEM SOC 2004. [DOI: 10.1590/s0103-50532004000500017] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
24
|
|
25
|
Análise de ácidos graxos por eletroforese capilar utilizando detecção condutométrica sem contato. QUIM NOVA 2003. [DOI: 10.1590/s0100-40422003000600007] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
26
|
|
27
|
Determination of mono- and disaccharides by capillary electrophoresis with contactless conductivity detection. Electrophoresis 2003; 24:2138-2143. [PMID: 12858386 DOI: 10.1002/elps.200305408] [Citation(s) in RCA: 75] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The separation and detection of common mono- and disaccharides by capillary electrophoresis (CE) with contactless conductivity detection (CCD) is presented. At high values of pH, the sugars are converted to anionic species that can be separated by CE and indirectly detected by CCD. The main anionic species present in the running electrolytes are hydroxide and phosphate, which have greater mobility than the ionized sugars, and, thus, the indirect detection is possible. The method was applied to analysis of glucose, fructose, and sucrose in soft drinks, isotonic beverages, fruit juice, and sugarcane spirits. Galactose was used as internal standard in all cases. Plate numbers range from ca. 70,700 to 168,200 and the limits of detection from 13 to 31 microM.
Collapse
|
28
|
Improved separation of IA and IIA metal cations in matrices with high sodium concentration by capillary electrophoresis with contactless conductometric detection. J BRAZIL CHEM SOC 2003. [DOI: 10.1590/s0103-50532003000200013] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
29
|
Contactless conductivity detection for capillary electrophoresis. Hardware improvements and optimization of the input-signal amplitude and frequency. J Chromatogr A 2002; 942:249-58. [PMID: 11826873 DOI: 10.1016/s0021-9673(01)01380-2] [Citation(s) in RCA: 115] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
A new prototype of contactless conductivity detector, smaller and easier to operate than the former version, is described. For a fused-silica capillary with 142-microm wall thickness and voltages up to 25 kV, it can be placed at the low- or high-voltage end of the column. This feature allowed implementation of an apparatus with sample introduction at the grounded end of the column. The input signal is an important parameter for determining the signal-to-noise ratio (S/N) of the detection system. An optimization procedure of its amplitude and frequency is proposed. Although the SIN must be determined by introduction of actual samples, the operating conditions can be optimized merely by changing the signal parameters and by using a mathematical procedure. Thus, an easy and fast optimization routine can be carried out. Mathematical and instrumental backgrounds are discussed, and experimental support of the technique's effectiveness is presented.
Collapse
|
30
|
Improving the sensitivity of electrode-separated piezoelectric quartz crystal sensor for copper(II) ions by immobilization of the N-2-aminoethyl-3-aminopropylsilane group. J BRAZIL CHEM SOC 2001. [DOI: 10.1590/s0103-50532001000100017] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
31
|
Desenvolvimento de um detector piezelétrico para cromatógrafo a gás interfaceado a microcomputador. QUIM NOVA 1999. [DOI: 10.1590/s0100-40421999000100020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
32
|
Automatização de um destilador d'água. QUIM NOVA 1998. [DOI: 10.1590/s0100-40421998000500020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
33
|
|
34
|
An equilibrium simulator for multiphase equilibria based on the extent of reaction and Newton-Raphson method with globally convergent strategy (SEQEx2). Anal Chim Acta 1996. [DOI: 10.1016/s0003-2670(96)00342-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
35
|
Fast Multidimensional (3D and 4D) MS2 and MS3 Scans in a High-Transmission Pentaquadrupole Mass Spectrometer. Anal Chem 1996. [DOI: 10.1021/ac9508659] [Citation(s) in RCA: 83] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|