1
|
Imageless navigation system (Naviswiss) provides accurate component position in total hip arthroplasty with lateral decubitus position for end-stage hip osteoarthritis: a prospective cohort study with CT-validation. ARTHROPLASTY 2024; 6:3. [PMID: 38191491 PMCID: PMC10773062 DOI: 10.1186/s42836-023-00224-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Accepted: 12/12/2023] [Indexed: 01/10/2024] Open
Abstract
AIMS The Naviswiss system (Naviswiss AG, Brugg, Switzerland) is a handheld imageless navigation device used to improve the accuracy of implant positioning in total hip arthroplasty (THA). However, clinical data for leg length discrepancy and femoral offset is lacking, and the validity of the system has not been reported for patients undergoing THA in the lateral decubitus position. This study aimed to report the accuracy of the device in this patient population. METHODS Patients underwent THA in the lateral decubitus position performed by a single surgeon. Component position measured by the device intraoperatively was compared to postoperative measurements on computed tomography (CT) scans. Agreement between the navigation system and postoperative measurements was reported for acetabular cup inclination, acetabular cup version, femoral offset, and leg length discrepancy. RESULTS Thirty-three patients were included in the analysis. The mean difference between intraoperative and postoperative CT measurements was within 2° for angular measurements and 2 mm for leg length. Absolute differences in the two indices were up to 4° and 3 mm. The mean bias was 1°-2° overestimation for cup orientation and up to 2 mm overestimation for leg length change. However, 95% limits of agreement did not exceed absolute thresholds of 10° and 10 mm, especially after correction for bias. One case (3%) was declared intraoperatively for issues with fixation on the greater trochanter. CONCLUSIONS The accuracy of the Naviswiss system falls within clinically acceptable recommendations for acetabular cup placement, femoral offset, and leg length for total hip arthroplasty with a anterolateral approach in lateral decubitus position. The system could be further improved with regression-based bias correction.
Collapse
|
2
|
Patient-reported outcomes of a short hospital stay after total knee replacement in a regional public hospital: a prospective cohort treated 2018-2019. ANZ J Surg 2022; 92:837-842. [PMID: 35187772 DOI: 10.1111/ans.17531] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 11/16/2021] [Accepted: 01/17/2022] [Indexed: 11/28/2022]
Abstract
BACKGROUND Patient-reported outcomes and satisfaction following short length of stay (LoS) after total knee arthroplasty (TKA) in the Australian regional context remain unexplored. This study reports complications, outcomes and satisfaction of patients discharged from an enhanced recovery protocol (ERP), 6 weeks after TKA in a regional hospital. METHODS Prospective recruitment occurred between 2018 and 2019. Demographics, intraoperative data, complications and emergency department (ED) presentations were retrieved from hospital records. Complications were graded for severity using a published scale. Knee range of motion (ROM), timed up-and-go (TUG), 6-min walk test (6MWT) and Oxford Knee Scores (OKS) were assessed preoperatively and 6 weeks postoperatively. Patient satisfaction was assessed via questionnaire at the postoperative follow-up. RESULTS One hundred patients/117 primary TKAs were prospectively included. Median LoS was 2 days (interquartile range 1-3 days) with 74.4% and 88.4% of patients satisfied with their knee and LoS, at 6 weeks respectively. Twenty-seven patients presented to the ED a total of 37 times with complication severity of Grade III or less, and 10 patients were readmitted. Significant improvements in objective and subjective outcomes were observed, however only change in median OKS exceeded the minimal clinically important difference (MCID) threshold. CONCLUSION An enhanced recovery protocol after TKA in a regional hospital can achieve a median LoS of 2 days without compromising patient-reported outcomes and objective functional measures, whilst maintaining a high level of patient satisfaction with both the surgery and LoS. Further work is required to better optimize management of largely low-grade complications in this patient population.
Collapse
|
3
|
Computer navigation re-creates planned glenoid placement and reduces correction variability in total shoulder arthroplasty: an in vivo case-control study. J Shoulder Elbow Surg 2019; 28:e398-e409. [PMID: 31353300 DOI: 10.1016/j.jse.2019.04.037] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2018] [Revised: 04/03/2019] [Accepted: 04/15/2019] [Indexed: 02/01/2023]
Abstract
BACKGROUND Accurate glenoid component placement is important to prevent glenoid component failure in total shoulder arthroplasty (TSA). Navigation may reduce the variability of glenoid component version and inclination; therefore, the aims of this study were to determine, in patients undergoing TSA, whether computer navigation improved the ability to achieve neutral postoperative version and inclination, as well as achieve the individualized preoperative plan. METHODS Patients undergoing TSA using navigation (computer-assisted surgery [CAS], n = 33) or the conventional technique (n = 27) from January 2014 to July 2017 were recruited and compared. Preoperative and postoperative version and inclination, as well as postoperative inferior overhang, were measured using computed tomography scans. RESULTS The CAS group had more than twice as many augmented glenoid components as the conventional group (45.5% vs. 19.2%). CAS significantly reduced the between-patient variability in postoperative version and led to a greater proportion of components positioned in "neutral" alignment for both inclination and version (P < .015). The incidence of neutral inclination or version postoperatively was significantly higher in the CAS group, and the glenoid was implanted within 5° of the surgical plan in more than 70% of cases, with more than 40% displaying no detectable difference. CONCLUSION An integrated system of 3-dimensional surgical planning, augmented glenoid components, and intraoperative navigation may reduce the risk of glenoid placement outside of a neutral position in patients undergoing TSA compared with conventional methods. This study demonstrated the capacity for CAS to replicate the surgical plan in a majority of cases.
Collapse
|
4
|
Letter to the Editor on "Mortality and Implant Survival With Simultaneous and Staged Bilateral Total Knee Arthroplasty Experience From the Australian Orthopedic Association National Joint Replacement Registry". J Arthroplasty 2019; 34:2192-2193. [PMID: 31204224 DOI: 10.1016/j.arth.2019.05.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Accepted: 05/14/2019] [Indexed: 02/01/2023] Open
|
5
|
Role of intraoperative navigation in the fixation of the glenoid component in reverse total shoulder arthroplasty: a clinical case-control study. J Shoulder Elbow Surg 2019; 28:1685-1691. [PMID: 31262637 DOI: 10.1016/j.jse.2019.03.013] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2018] [Revised: 02/28/2019] [Accepted: 03/07/2019] [Indexed: 02/01/2023]
Abstract
BACKGROUND Fixation of the glenoid baseplate in reverse total shoulder arthroplasty (rTSA) is an important factor in the success of the procedure. There is limited information available regarding the effect of navigation on fixation characteristics. Therefore, the aims of this study were to determine whether computed tomography-based computer navigation improved the glenoid base plate fixation by (1) increasing the length of screw purchase, (2) altering screw angulation, and (3) decreasing central cage perforation in patients undergoing rTSA. METHODS Patients undergoing rTSAs using navigation (NAV, N = 27) and manual technique (MAN, N = 23) from January 2014 to July 2017 were analyzed in a case-control design. Screw purchase length and central cage perforation were assessed using multiplanar computed tomography. RESULTS Median screw purchase length was significantly longer in the NAV group for both anterior (20 mm vs. 15 mm, P < .01) and posterior screws (20 mm vs. 13 mm, P < .01). In addition, the NAV group displayed significantly lower incidences of inadequate screw purchase (<22 mm) for the anterior (64.7% vs. 95.2%, P = .03) and posterior (70.6% vs. 100%, P = .01) screws. Significant differences in axial and coronal screw angulation were observed between groups. Similarly, the NAV group displayed significantly reduced incidence of central cage perforation (17.7% vs. 52.4%, P = .04). CONCLUSION The use of computer-assisted navigated rTSA contributes to significant alterations in screw purchase length, screw angulation, and central cage perforation of the glenoid baseplate compared with non-navigated methods.
Collapse
|
6
|
Towards a Dynamic Model of the Kangaroo Knee for Clinical Insights into Human Knee Pathology and Treatment: Establishing a Static Biomechanical Profile. Biomimetics (Basel) 2019; 4:biomimetics4030052. [PMID: 31349696 PMCID: PMC6784414 DOI: 10.3390/biomimetics4030052] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Revised: 07/19/2019] [Accepted: 07/23/2019] [Indexed: 12/23/2022] Open
Abstract
There is limited understanding of how patella realignment or patellectomy to surgically manage patellofemoral pain (PFP) affects knee biomechanics. By analysing marsupials like kangaroos that lack an ossified patella, actionable biomimetic insight for the management of end-stage PFP could be gained. This study aimed to provide the foundation of a multi-stage approach, by establishing a static biomechanical profile of the kangaroo stifle that informs the inputs and factors requiring consideration for future dynamic analyses. Volumetric CT and MRI sequences were obtained for four hindlimbs from two Macropus giganteus specimens, from which three-dimensional models of the stifles were created. Two limbs were dissected to visualise the insertion points, origins and lines of action of the quadriceps muscles and the knee extensor mechanism. Static measurements were obtained from the three-dimensional models to establish the biomechanical profile. The results confirmed structural differences in the kangaroo stifle with lack of an ossified patella, a prominent tuberosity and a shorter femur, which functionally affect the mechanical advantage and the torque-generating capability of the joint. The data reported in this study can be used to inform the inputs and constraints of future comparative analyses from which important lessons can be learned for the human knee.
Collapse
|
7
|
Factors affecting the incidence and management of fixed flexion deformity in total knee arthroplasty: A systematic review. Knee 2018; 25:352-359. [PMID: 29681527 DOI: 10.1016/j.knee.2018.03.008] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2017] [Revised: 12/11/2017] [Accepted: 03/11/2018] [Indexed: 02/02/2023]
Abstract
PURPOSE This study aimed to systematically review the literature and identify factors which would contribute to the intraoperative correction of FFD to frame a potential surgical algorithm or predictive model to guide intraoperative decision-making. METHODS Electronic searches of six databases were undertaken in April 2016 according to the PRISMA guidelines, and the reference lists of studies searched. Quality of studies was assessed using the STROBE checklist, and the Downs and Black Scores. RESULTS Twenty-five studies investigating 10, 679 knees were found to satisfy the inclusion and exclusion criteria. These studies described a variety of pre-operative and intra-operative factors which contribute to the development or correction of post-operative FFD. The only patient predictor of post-operative FFD was pre-operative FFD. The intra-operative steps described to correct FFD were: distal femoral resection, soft-tissue balancing (in the posterior and medial compartments), sagittal component flexion and posterior condylar offset. However, no studies investigated these in an integrated model. CONCLUSION This review has identified various pre-, intra- and post-operative factors predictive of post-operative FFD. In practice, these factors are likely to interact, and therefore further investigation in an integrated model is crucial to developing a statistically sound and reliable intraoperative algorithm for surgeons to follow when correcting fixed flexion deformity.
Collapse
|
8
|
Multiobjective optimization of cartilage stress for non-invasive, patient-specific recommendations of high tibial osteotomy correction angle - a novel method to investigate alignment correction. Med Eng Phys 2017; 42:26-34. [PMID: 28209345 DOI: 10.1016/j.medengphy.2016.11.013] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2016] [Revised: 10/13/2016] [Accepted: 11/09/2016] [Indexed: 10/20/2022]
Abstract
Medial opening wedge high tibial osteotomy (MOWHTO) is a surgical procedure to treat knee osteoarthritis associated with varus deformity. However, the ideal final alignment of the Hip-Knee-Ankle (HKA) angle in the frontal plane, that maximizes procedural success and post-operative knee function, remains controversial. Therefore, the purpose of this study was to introduce a subject-specific modeling procedure in determining the biomechanical effects of MOWHTO alignment on tibiofemoral cartilage stress distribution. A 3D finite element knee model derived from magnetic resonance imaging of a healthy participant was manipulated in-silico to simulate a range of final HKA angles (i.e. 0.2°, 2.7°, 3.9° and 6.6° valgus). Loading and boundary conditions were assigned based on subject-specific kinematic and kinetic data from gait analysis. Multiobjective optimization was used to identify the final alignment that balanced compressive and shear forces between medial and lateral knee compartments. Peak stresses decreased in the medial and increased in the lateral compartment as the HKA was shifted into valgus, with balanced loading occurring at angles of 4.3° and 2.9° valgus for the femoral and tibial cartilage respectively. The concept introduced here provides a platform for non-invasive, patient-specific preoperative planning of the osteotomy for medial compartment knee osteoarthritis.
Collapse
|
9
|
Lack of agreement between computer navigation and post-operative 2-dimensional computed tomography (CT) measurements for component and limb alignment in total knee arthroplasty (TKA). Knee 2016; 23:137-43. [PMID: 26282326 DOI: 10.1016/j.knee.2015.07.009] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/21/2014] [Revised: 07/01/2015] [Accepted: 07/15/2015] [Indexed: 02/02/2023]
Abstract
BACKGROUND The purpose of this study was to assess the degree of mismatch between intraoperative navigation data using imageless computer navigation and post-operative CT scan measurements with respect to bone cuts, component and limb alignment during TKA. METHODS Intraoperative navigation data including bone cut verification and overall limb alignment during TKA was compared to postoperative CT measurements of component and limb alignment according to the Perth protocol. The proportion of cases with mismatch between navigation and CT measurements at two and three degree thresholds was identified. RESULTS In a total sample of 50 primary TKAs, 20% of cases showed a mismatch of more than two degrees between navigation and CT obtained measurements for coronal femoral alignment, 42% for femoral rotation, 16% for tibial component coronal alignment and 32% for overall limb alignment. CONCLUSION Mismatch between intraoperative navigation data and postoperative CT measurements suggests that postoperative CT scan alignment data should be interpreted with caution. A surgeon should consider a multitude of factors when analysing component and limb alignment postoperatively.
Collapse
|
10
|
Unsatisfactory accuracy with VISIONAIRE patient-specific cutting jigs for total knee arthroplasty. J Arthroplasty 2014; 29:249-50. [PMID: 23891059 DOI: 10.1016/j.arth.2013.05.020] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2013] [Accepted: 05/15/2013] [Indexed: 02/01/2023] Open
|
11
|
Young men utilise limited neuromuscular preparation to regulate post-impact knee mechanics during step landing. Gait Posture 2014; 39:284-90. [PMID: 23978695 DOI: 10.1016/j.gaitpost.2013.07.127] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/19/2012] [Revised: 06/20/2013] [Accepted: 07/26/2013] [Indexed: 02/02/2023]
Abstract
PURPOSE The neuromuscular mechanisms determining the mechanical behaviour of the knee during landing impact remain poorly understood. It was hypothesised that neuromuscular preparation is subject-specific and ranges along a continuum from passive to active. METHODS A group of healthy men (N=12) stepped-down from a knee-high platform for 60 consecutive trials. Surface EMG of the quadriceps and hamstrings was used to determine pre-impact onset timing, activation amplitude and cocontraction for each trial. Partial least squares regression was used to associate pre-impact preparation with post-impact knee stiffness and coordination. RESULTS The group analysis revealed few significant changes in pre-impact preparation across trial blocks. Single-subject analyses revealed changes in muscle activity that varied in size and direction between individuals. Further, the association between pre-impact preparation and post-impact knee mechanics was subject-specific and ranged along a continuum of strategies. CONCLUSION The findings suggest that neuromuscular preparation during step landing is subject-specific and its association to post-impact knee mechanics occurs along a continuum, ranging from passive to active control strategies. Further work should examine the implications of these strategies on the distribution of knee forces in vivo.
Collapse
|
12
|
In vivo assessment of weight-bearing knee flexion reveals compartment-specific alterations in meniscal slope. Arthroscopy 2013; 29:1653-60. [PMID: 23993055 DOI: 10.1016/j.arthro.2013.07.260] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/11/2012] [Revised: 07/09/2013] [Accepted: 07/10/2013] [Indexed: 02/02/2023]
Abstract
PURPOSE The purpose of this study was to determine the effects of flexion angle on meniscal slope during partial weight-bearing knee flexion. METHODS Forty-eight sagittal sequences were performed on 12 patients (6 male patients, 6 female patients; 25.7 ± 10.5 years) during partial weight bearing in an open magnetic resonance imaging (MRI) scanner at full extension, 60°, 90°, and maximum knee flexion. A previously published method was used to measure the meniscal slope for each compartment using manual digitalization. A general linear model was used to test for effects of compartment and flexion angle on meniscal slope. RESULTS The mean maximum flexion angle achieved was 125° ± 10.5°. A significant main effect of compartment (P < .01) and flexion angle (P < .01) on meniscal slope was observed. A significant interaction between compartment and angle was also detected (P < .01). Specifically, the lateral meniscal slope was significantly more horizontal than the medial meniscus slope at full extension (P = .017) but significantly more posterior at all other angles. In addition, the lateral meniscus displayed a greater change in posterior slope across the range of motion compared with the medial meniscus. Significant correlations were found in medial meniscal slope at full extension and at maximum knee flexion (P = .031). CONCLUSIONS The results showed that meniscal slope in healthy knees increased significantly with knee flexion for both menisci, with significantly greater changes in the lateral meniscus. Furthermore, a lack of correlation was observed between the meniscal slope in extension and the meniscal slope at increasing flexion angles, questioning the efficacy of measuring the meniscal slope only in extension as commonly described. Overall, this study has provided valuable insight into how meniscal slope changes with knee motion.
Collapse
|
13
|
A Comparison of the Temperature Rise Generated in Bone by the Use of a Standard Oscillating Saw Blade and the “Precision” Saw Blade. J Med Device 2013. [DOI: 10.1115/1.4024159] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Introduction. Osteonecrosis may be triggered by bone temperatures above 47 °C during routine orthopaedic bone cuts using power-driven saws with potentially negative impacts on bone healing. A new oscillating-tip saw blade design (Precision®; Stryker, Kalamazoo, USA) has been recently developed with a saw blade design that may influence the amount of heat generated. We have, therefore, sought to compare the bone temperature achieved using this new blade design with a standard oscillating saw during a standardized cutting task. Method. Six human cadaveric femora were obtained. Each femur was clamped and a distal femoral cutting jig was applied. An initial cut was performed to visualize the distal metaphyseal bone. The cutting block was then moved 2 mm proximal and a further cut performed, measuring the temperature of the bone with an infrared camera. This was repeated, moving the block 2 mm proximal with each cut, alternating between a standard oscillating saw blade (12 cuts) and the Precision® saw blade (12 cuts). The bone density at the level of each slice was established from a CT scan of each specimen which had been performed prior to the experiment. Results. The two blades did not differ with respect to the integrated mean temperature calculated for each cut (p = 0.89). The average peak temperatures were not significantly different between blades (p = 0.14). There was no significant difference between blades for peak heating rate (p = 0.7), although the area of bone heated above the 47 deg osteonecrotic threshold was significantly (p = 0.04) less for the standard saw blade. Conclusions. The Precision® blade may have advantages over standard oscillating blade, but reduced heat generation was not observed in this study. Indeed, the Precision® blade generated heat that exceeded the bony osteonecrosis threshold in a greater proportion of bone than the standard blade, questioning its use for osteotomy or uncemented knee arthroplasty. Further work should examine modifications to the blade design to better optimize the requirements of speed, accuracy and heat generation.
Collapse
|
14
|
Incidence and severity of complications due to femoral nerve blocks performed for knee surgery. Knee 2013; 20:181-5. [PMID: 23276419 DOI: 10.1016/j.knee.2012.11.002] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2012] [Revised: 11/01/2012] [Accepted: 11/12/2012] [Indexed: 02/02/2023]
Abstract
BACKGROUND While single shot femoral nerve blocks and indwelling femoral nerve catheters provide significant peri-operative analgesia, there are small but serious risks of neurovascular complications. We aimed to determine the incidence and characterise the nature of neural complications arising from femoral nerve blocks performed for knee surgery. METHODS One thousand eight hundred and two patients receiving a femoral nerve block for knee surgery during the study period were screened. Patients with possible neurological symptoms were evaluated with a detailed physical examination and self-report questionnaires. Also measures of depression, anxiety and tension/stress were collected. RESULTS In the patients screened, an incidence of 1.94% was found. Of the 24 patients available for testing, 4 had bilateral symptoms following bilateral nerve blocks. All had sensory abnormalities in the distribution of the femoral nerve. The incidence was significantly higher in females (females=2.5%, males=0.83% p=0.01) and in patients receiving a single shot block (single shot=2.66%, femoral catheter=0.93, p=0.01). CONCLUSIONS The incidence of neurological complication after FNB was higher in this series than typically reported and the symptoms significantly influenced the quality of life in the affected cases. The decision to include a femoral nerve block in the peri-operative analgesic regimen should be made on an individual basis considering the risks and benefits.
Collapse
|
15
|
Can tibial coverage in total knee replacement be reliably evaluated with three-dimensional image-based digital templating? Bone Joint Res 2013; 2:1-8. [PMID: 23610696 PMCID: PMC3626184 DOI: 10.1302/2046-3758.21.2000130] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2012] [Accepted: 10/29/2012] [Indexed: 11/26/2022] Open
Abstract
Objectives There remains a lack of data on the reliability of methods to
estimate tibial coverage achieved during total knee replacement.
In order to address this gap, the intra- and interobserver reliability
of a three-dimensional (3D) digital templating method was assessed
with one symmetric and one asymmetric prosthesis design. Methods A total of 120 template procedures were performed according to
specific rotational and over-hang criteria by three observers at
time zero and again two weeks later. Total and sub-region coverage
were calculated and the reliability of the templating and measurement
method was evaluated. Results Excellent intra- and interobserver reliability was observed for
total coverage, when minimal component overhang (intraclass correlation
coefficient (ICC) = 0.87) or no component overhang (ICC = 0.92)
was permitted, regardless of rotational restrictions. Conclusions Measurement of tibial coverage can be reliable using the templating
method described even if the rotational axis selected still has
a minor influence.
Collapse
|
16
|
Unsatisfactory accuracy as determined by computer navigation of VISIONAIRE patient-specific instrumentation for total knee arthroplasty. J Arthroplasty 2013; 28:469-73. [PMID: 23151366 DOI: 10.1016/j.arth.2012.07.012] [Citation(s) in RCA: 82] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2012] [Revised: 06/15/2012] [Accepted: 07/02/2012] [Indexed: 02/01/2023] Open
Abstract
This investigation evaluated the Smith and Nephew VISIONAIRE patient-specific cutting block (PSCB) system for total knee arthroplasty. A consecutive series of 60 patients was recruited. Intraoperative computer navigation was used to evaluate the accuracy of the cutting blocks in the coronal and sagittal planes for the tibia, as well as rotational plane for the femur. The PSCB would have placed 79.3% of the sample within ±3° of the preoperative plan in the coronal plane, while the rotational and sagittal alignment results within ±3° were 77.2% and 54.5% respectively. The VISIONAIRE PSCB system achieved unacceptable accuracy when assessed by computer navigation. There might be many sources of error, but caution is recommended before using this system routinely without objective verification of alignment.
Collapse
|
17
|
Different changes in slope between the medial and lateral tibial plateau after open-wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 2013; 21:32-8. [PMID: 23052121 DOI: 10.1007/s00167-012-2229-6] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/17/2012] [Accepted: 09/20/2012] [Indexed: 01/22/2023]
Abstract
PURPOSE In contrast to radiographic measurements, MRI provides multiple slices of the knee joint in the sagittal plane, making it possible to assess the medial and lateral tibial slope separately. The purpose of this study is to investigate the effect of medial open-wedge high tibial osteotomy (MOWHTO) on bony and meniscal slope in the medial and lateral tibiofemoral compartments. It was hypothesised that greater changes on the medial tibial plateau would be observed compared with the lateral one. METHODS A retrospective analysis of prospectively collected data was performed on pre- and post-operative MRIs from 21 patients (17 men and 4 women; age 52 ± 9 years). Inclusion criteria were varus alignment, medial compartment osteoarthritis and election for a primary MOWHTO. Each patient had a preoperative and a post-operative high-resolution MRI (3Tesla, Magnetom Trio, Siemens AG) at an average follow-up of 2.1 years. A previously published method was used to measure bony and meniscal slope for each compartment. The difference between pre- and post-operative tibial slope for both compartments was calculated and associated with the amount of frontal correction. RESULTS There was a significant increase in bony tibial slope in both compartments following MOWHTO. When a change in bony tibial slope was detected in an individual patient, the change was larger in the medial compartment, with the average change also significantly greater (p < 0.01) in the medial compartment (2.4° ± 1.3°) compared with the lateral compartment (0.9° ± 1.1°). There was also a significant increase (p < 0.01) in the lateral tibial meniscal slope of 0.9° ± 1.4°, which was equivalent to the change in the bony lateral slope. The amount of frontal correction was not significantly associated with the amount of change in slope. CONCLUSIONS The results suggest that the modification of the bony slope is larger in the medial compartment after MOWHTO, which is likely related to the location of the hinge on the lateral tibial cortex. These findings suggest that consideration of the medial and lateral tibial slope intra-operatively could be important to identify the optimal location of the hinge. However, further studies are required before recommending any modification to the surgical technique, as the potential clinical consequences of tibial slope alterations remain unknown. LEVEL OF EVIDENCE IV.
Collapse
|
18
|
Is femoral nerve block necessary during total knee arthroplasty?: a randomized controlled trial. J Arthroplasty 2012; 27:1800-5. [PMID: 22658231 DOI: 10.1016/j.arth.2012.03.052] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2011] [Accepted: 03/28/2012] [Indexed: 02/01/2023] Open
Abstract
There remains a lack of randomized controlled trials comparing methods of perioperative analgesia for total knee arthroplasty. To address this deficiency, a blinded, randomized controlled trial was conducted to compare the use of femoral nerve block (group F) and local anesthetic (group L). A sample of 55 patients who met the inclusion criteria were randomized to either group. No significant differences in the most severe pain score or 36-Item Short Form Health Survey, The Western Ontario and McMaster Universities Arthritis Index (WOMAC), or Oxford scores were observed between groups. However, the Knee Society score was significantly higher in group F. In addition, group F used significantly fewer micrograms of intravenous fentanyl in the first 24 hours. Balancing the risks of femoral nerve block with those of increased systemic narcotic delivery should be performed on a case-by-case basis.
Collapse
|
19
|
Single-subject analysis reveals variation in knee mechanics during step landing. J Biomech 2012; 45:2074-8. [DOI: 10.1016/j.jbiomech.2012.05.046] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2012] [Revised: 05/28/2012] [Accepted: 05/28/2012] [Indexed: 10/28/2022]
|
20
|
Sagittal placement of the femoral component in total knee arthroplasty predicts knee flexion contracture at one-year follow-up. INTERNATIONAL ORTHOPAEDICS 2012; 36:1835-9. [PMID: 22638608 DOI: 10.1007/s00264-012-1580-z] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2012] [Accepted: 05/09/2012] [Indexed: 11/25/2022]
Abstract
PURPOSE Flexion contracture has been shown to impair function and reduce satisfaction following total knee arthroplasty (TKA). The aim of this study was to identify modifiable intra-operative variables that predict post-TKA knee extension. METHODS Data was collected prospectively on 95 patients undergoing total knee arthroplasty, including pre-operative assessment, intra-operative computer assisted surgery (CAS) measurements and functional outcome including range of motion at one year. Patients were divided into two groups: those with mild flexion contracture (> 5°) at the one-year follow-up and those achieving full extension. RESULTS The sagittal orientation of the distal femoral cut differed significantly between groups at the one-year follow-up (p = 0.014). Sagittal alignment of greater than 3.5° from the mechanical axis was shown to increase the relative risk of a mild flexion contracture at one-year follow-up by 2.9 times, independent of other variables. CONCLUSION Increasing the sagittal alignment of the distal femoral cut more than 3.5° from the mechanical axis is an independent risk factor for clinically detectable flexion contracture one year from index procedure.
Collapse
|
21
|
Tibial fixation in anterior cruciate ligament reconstruction: a prospective randomized study comparing metal interference screw and staples with a centrally placed polyethylene screw and sheath. Am J Sports Med 2011; 39:1858-64. [PMID: 21622815 DOI: 10.1177/0363546511406234] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND The use of hamstring tendons for anterior cruciate ligament reconstruction has increased in popularity over recent years. However, concerns with the stability of graft fixation on the tibial side remain. Centrally placed interference screw/sheath implants have demonstrated promising results in biomechanical studies. HYPOTHESIS Centrally placed, polyethylene screw and sheath implants will provide clinically equivalent fixation to the standard metal interference screw and supplemental staple fixation. STUDY DESIGN Randomized controlled trial; Level of evidence, 1. METHODS A total of 113 consecutive patients undergoing isolated, unilateral, primary anterior cruciate ligament reconstruction with hamstring autografts were randomized to tibial fixation with metal interference screw and staples (RCI) or with a centrally placed polyethylene screw and sheath implant (INTRAFIX). Prospective assessment of subjective outcomes was performed using Lysholm, Mohtadi, and International Knee Documentation Committee (IKDC) scores. RESULTS At minimum 2-year follow-up, there were no significant differences between the 2 groups in terms of instrumented stability testing (KT-1000 arthrometer) or subjective assessment of knee outcomes (IKDC, Lysholm, Mohtadi). Both fixation methods demonstrated a significant, but not different, increase in outcomes scores from preoperative to postoperative evaluation. There were 7 failures (5 INTRAFIX, 2 RCI) caused by reinjury, but no statistically significant differences were observed between the 2 fixation methods. CONCLUSION The centrally placed polyethylene screw and sheath provided equivalent clinical outcomes at minimum 2-year follow-up to standard tibial fixation with metal interference screw and staples.
Collapse
|
22
|
Abstract
BACKGROUND High tibial osteotomy (HTO) is a method used to treat medial compartmental osteoarthritis in the knee. The realignment of the knee changes the loading patterns within the joint and may allow for regeneration of articular cartilage. Magnetic resonance imaging methods can be used to assess the quality of the regenerated cartilage. HYPOTHESIS Altering mechanical alignment through HTO will have predictable effects on articular cartilage, allowing cartilage preservation and possible regeneration. Quality of regenerated cartilage will be inferior to normal articular cartilage. STUDY DESIGN Case series; Level of evidence, 4. METHODS Ten patients undergoing medial opening wedge HTO were evaluated using dGEMRIC methods (ie, delayed gadolinium-enhanced magnetic resonance imaging of cartilage) preoperatively and at 6 months, 1 year, and 2 years after HTO. Magnetic resonance images were evaluated by hand segmentation, and T1(Gd) relaxation times reflective of glycosaminoglycan content were determined for these regions of interest using magnetic resonance imaging analysis software. RESULTS The lateral compartment displayed higher T1(Gd) values than the medial compartment at baseline. Initially, a decrease in T1(Gd) values on the medial side were observed for all patients at 6 months and remained reduced for all but 2 participants at 1 year and 2 years after HTO. However, on the medial side after 6 months, the rate of change for T1(Gd) values shifted from being negative (-9.6 milliseconds per month) to being positive (1.7 milliseconds per month). A positive change in the T1(Gd) of the medial tibial plateau was responsible for the positive overall change in the medial compartment. There was no significant difference in the rate of change on the lateral side (P = .141), with the average over the 2-year period being a decrease of 2.28 milliseconds per month. CONCLUSION Medial opening wedge HTO provides subjective improvements in pain and quality of life, but the potential benefit of allowing articular cartilage preservation and possible regeneration is not well established. Results showed that after a nonweightbearing period, the rate of change in the medial compartment changes from negative to positive, indicating the potential for articular cartilage recovery secondary to an improved mechanical environment.
Collapse
|