1
|
Comparison of Clinical and Biomechanical Outcomes of Small Incision Lenticule Extraction With 120- and 140-µm Cap Thickness. Transl Vis Sci Technol 2021; 10:15. [PMID: 34259803 PMCID: PMC8288062 DOI: 10.1167/tvst.10.8.15] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose The purpose of this study was to compare the clinical outcomes and corneal biomechanical changes between 120-µm and 140-µm cap thickness after small incision lenticule extraction (SMILE). Methods This prospective study included 150 eyes (150 patients: 91 eyes in the 120-µm group, and 59 eyes in the 140-µm group) who underwent SMILE. Enhanced correction nomograms were applied for patients according to cap thickness. Clinical outcomes, including visual acuity, refraction, and corneal wavefront aberrations, were compared between the two groups. Corneal biomechanics were evaluated using the Corvis ST (Oculus, Wetzlar, Germany). Results The mean uncorrected-distance visual acuity, safety and efficacy indices, and refractive predictability were comparable in the 120-µm and 140-µm groups after SMILE. The postoperative total corneal root mean square higher-order aberrations (HOAs) and spherical aberrations was 0.48 ± 0.31 and 0.26 ± 0.10 in the 120-µm group, and 0.53 ± 0.16 and 0.34 ± 0.13 in the 140-µm group, which showed significant differences between the two groups (P = 0.027, and <0.001, respectively). Although corneal stiffness decreased after SMILE in both groups, the changes in the deformation amplitude ratio were significantly higher in the 140-µm group than in the 120-µm group (P = 0.022). Conclusions SMILE with 120-µm and 140-µm cap thickness provided excellent predictable outcomes according to our enhanced correction nomogram. The amount of tissue removal required to achieve the same amount of refractive correction was greater in the thicker cap group. The induction of corneal HOAs and weakening of corneal biomechanics were less pronounced in the thin-cap group, which may be associated with the thinner cap, lesser lenticule thickness, or thicker residual stromal bed. Translational Relevance Although SMILE with different cap thickness was effective, thicker lenticule thickness in the thick-cap group may be associated with induction of HOAs, and corneal stiffness changes.
Collapse
|
2
|
Comparison of clinical outcomes between vector planning and manifest refraction planning in SMILE for myopic astigmatism. J Cataract Refract Surg 2021; 46:1149-1158. [PMID: 32347695 DOI: 10.1097/j.jcrs.0000000000000100] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To compare clinical outcomes of small-incision lenticule extraction (SMILE) between manifest refraction (MR) and vector planning for myopic astigmatism with high ocular residual astigmatism (ORA). SETTING Yonsei University College of Medicine and Eyereum Eye Clinic, Seoul, South Korea. DESIGN Prospective, randomized, comparative case series. METHODS Patients with myopic astigmatism and ORA of 0.75 diopters (D) or greater were randomized into the MR or vector planning group and underwent SMILE without applying any nomogram for cylinder correction. Visual acuity, MR, corneal topography, and corneal aberration were measured preoperatively and postoperatively. Outcomes at 6 months postoperatively were compared between the groups. RESULTS The study comprised 114 patients (114 eyes): 58 eyes in MR planning and 56 eyes in vector planning. The mean uncorrected and corrected distance visual acuity, safety and efficacy indices were comparable between the 2 groups. Postoperative refractive cylinder reached statistically significant differences between the groups (-0.22 ± 0.18 D and -0.14 ± 0.16 D in the MR and vector planning groups, respectively, P = .02). Postoperative corneal toricity and ORA reached statistically significant lower in the vector planning group. CONCLUSIONS In myopic astigmatism with high ORA, MR and vector planning in SMILE were effective with comparable visual outcomes; vector planning showed statistically significant lower postoperative refractive and corneal astigmatism and ORA. Use of vector planning may improve refractive outcomes in SMILE cases with high ORA. However, the results may have been different had a nomogram adjustment been applied, as is often used for cylinder corrections with SMILE.
Collapse
|
3
|
Five-year Change in Corneal Endothelial Cell Density after Foldable Iris-fixed Lens Insertion. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2021. [DOI: 10.3341/jkos.2021.62.4.479] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
4
|
Reply to comment on: Comparison of clinical outcomes between vector planning and manifest refraction planning in small-incision lenticule extraction for myopic astigmatism. J Cataract Refract Surg 2021; 47:142-143. [PMID: 33901097 DOI: 10.1097/j.jcrs.0000000000000512] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
5
|
Effect of Corneal Cross-linking on Epithelial Hyperplasia and Myopia Regression After Transepithelial Photorefractive Keratectomy. J Refract Surg 2019; 35:354-361. [PMID: 31185100 DOI: 10.3928/1081597x-20190422-01] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2018] [Accepted: 04/22/2019] [Indexed: 11/20/2022]
Abstract
PURPOSE To investigate the effect of accelerated corneal cross-linking (CXL) on epithelial thickness change and refractive outcome after myopic transepithelial photorefractive keratectomy (TPRK). METHODS This study compared epithelial thickness changes in 49 patients undergoing TPRK-CXL with 49 patients undergoing TPRK who were matched for age and refractive error. Corneal epithelial thickness, obtained using spectral-domain optical coherence tomography preoperatively and 12 months postoperatively, was compared between the groups. Regression analysis was performed to investigate the association between changes in epithelial thickness and keratometric power. Factors affecting myopic regression (> 0.50 diopters] were evaluated using logistic regression analysis. RESULTS For TPRK, the mean epithelial thickness of the center (2-mm diameter), paracenter (2- to 5-mm diameter), and pericenter (5- to 6-mm diameter) increased by 6.5 ± 3.1, 7.0 ± 2.9, and 4.9 ± 2.9 µm, respectively; increases of 4.8 ± 3.0, 5.9 ± 2.8, and 4.8 ± 2.7 µm were observed following TPRK-CXL, indicating a significant difference in the center (P = .013). Epithelial thickness increased linearly to the magnitude of myopic correction and was negatively correlated with the optical zone diameter of ablation. Change in epithelial thickness showed a linear correlation with the change in keratometric power between 1 and 12 months postoperatively, indicating regression in eyes following TPRK. Corneal epithelial thickening was significantly associated with myopic regression and simultaneous CXL tended to reduce the risk of regression. CONCLUSIONS TPRK-CXL induces less epithelial hyperplasia than does TPRK, presumably owing to the effect of CXL, and the magnitude of epithelial thickening seemed to be associated with myopic regression. [J Refract Surg. 2019;35(6):354-361.].
Collapse
|
6
|
Effect of accelerated corneal crosslinking combined with transepithelial photorefractive keratectomy on dynamic corneal response parameters and biomechanically corrected intraocular pressure measured with a dynamic Scheimpflug analyzer in healthy myopic patients. J Cataract Refract Surg 2019; 43:937-945. [PMID: 28823441 DOI: 10.1016/j.jcrs.2017.04.036] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2017] [Revised: 04/12/2017] [Accepted: 04/12/2017] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the effect of accelerated corneal crosslinking (CXL) combined with transepithelial photorefractive keratectomy (PRK) on changes in new dynamic corneal response parameters and the biomechanically corrected intraocular pressure (IOP) measured using a dynamic Scheimpflug analyzer (Corvis ST). SETTING Yonsei University College of Medicine and Eyereum Eye Clinic, Seoul, South Korea. DESIGN Retrospective case series. METHODS Medical records of eyes of healthy myopic patients having transepithelial PRK or transepithelial PRK with CXL were examined. Main outcome variables were the biomechanically corrected IOP and new dynamic corneal response parameters including the deformation amplitude ratio at 1.0 mm (DAR1) and at 2.0 mm (DAR2), stiffness at first applanation and at highest concavity, and the integrated inverse radius preoperatively and 6 months postoperatively. RESULTS The study comprised 69 eyes (69 patients); 35 had transepithelial PRK and 34, transepithelial PRK with CXL. The DAR1, DAR2, and integrated inverse radius significantly increased, while stiffness at first applanation and at highest concavity decreased postoperatively in both groups. Changes in the DAR2 and integrated inverse radius in the transepithelial PRK group were significantly larger than in the transepithelial PRK with CXL group without and with analysis of covariance with the spherical equivalent change or corneal thickness change as a covariate. No significant differences in the biomechanically corrected IOP occurred preoperatively or postoperatively in either group. CONCLUSIONS Results indicate that prophylactic CXL combined with transepithelial PRK has a role in reducing the change in corneal biomechanical properties. The dynamic Scheimpflug analyzer showed stable biomechanically corrected IOP measurements preoperatively and postoperatively.
Collapse
|
7
|
Comparison of clinical outcomes between wavefront-optimized versus corneal wavefront-guided transepithelial photorefractive keratectomy for myopic astigmatism. J Cataract Refract Surg 2019; 43:174-182. [PMID: 28366363 DOI: 10.1016/j.jcrs.2016.11.045] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2016] [Revised: 11/21/2016] [Accepted: 11/22/2016] [Indexed: 10/19/2022]
Abstract
PURPOSE To evaluate and compare the clinical outcomes, including visual acuity, refractive errors, and aberrations, between aberration-free transepithelial photorefractive keratectomy (PRK) and corneal wavefront-guided transepithelial PRK in eyes with myopic astigmatism. SETTING Yonsei University College of Medicine and Eyereum Eye Clinic, Seoul, South Korea. DESIGN Retrospective comparative case series. METHODS Patients with myopic astigmatism were treated with aberration-free transepithelial PRK or corneal wavefront-guided transepithelial PRK using a 1050 Hz high-repetition excimer laser. The safety, efficacy, predictability, and corneal aberrations were compared preoperatively and 1, 2, 3, and 6 months postoperatively. RESULTS The study comprised 188 patients (188 eyes); 91 eyes had aberration-free transepithelial PRK and 97 eyes corneal wavefront-guided transepithelial PRK. Six month after surgery, the mean uncorrected distance visual acuity was comparable (-0.06 logMAR ± 0.07 [SD] aberration-free group; -0.06 ± 0.06 logMAR wavefront-guided group). The safety, efficacy, and predictability of refractive and visual outcomes were also comparable between groups. Corneal total root-mean-square (RMS) higher-order aberrations (HOAs) increased after treatment in both groups, although fewer RMS HOAs were induced in the corneal wavefront-guided group than in the aberration-free group. Spherical aberration increased similarly after treatment in both groups. However, coma and trefoil increased only in the aberration-free group. CONCLUSIONS Aberration-free transepithelial PRK and corneal wavefront-guided transepithelial PRK were safe and effective for correction of myopic astigmatism without difference in visual acuity and refractive outcomes. However, the corneal wavefront-guided profile induced fewer corneal aberrations than the aberration-free profile.
Collapse
|
8
|
Changes in biomechanically corrected intraocular pressure and dynamic corneal response parameters before and after transepithelial photorefractive keratectomy and femtosecond laser-assisted laser in situ keratomileusis. J Cataract Refract Surg 2019; 43:1495-1503. [PMID: 29335093 DOI: 10.1016/j.jcrs.2017.08.019] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2017] [Revised: 08/25/2017] [Accepted: 08/28/2017] [Indexed: 11/16/2022]
Abstract
PURPOSE To evaluate the changes in biomechanically corrected intraocular pressure (IOP) and new dynamic corneal response parameters measured by a dynamic Scheimpflug analyzer before and after transepithelial photorefractive keratectomy (PRK) and femtosecond laser-assisted laser in situ keratomileusis (LASIK). SETTING Yonsei University College of Medicine and Eyereum Eye Clinic, Seoul, South Korea. DESIGN Retrospective case series. METHODS Medical records of patients having transepithelial PRK or femtosecond-assisted LASIK were examined. The primary outcome variables were biomechanically corrected IOP and dynamic corneal response parameters, including deformation amplitude ratio 2.0 mm, stiffness parameter at first applanation, Ambrósio relational thickness through the horizontal meridian, and integrated inverse radius before the procedure and 6 months postoperatively. RESULTS Of the 129 patients (129 eyes) in the study, 65 had transepithelial PRK and 64 had femtosecond-assisted LASIK. No significant differences in biomechanically corrected IOP were noted before and after surgery. The deformation amplitude ratio 2.0 mm and integrated inverse radius increased, whereas the stiffness parameter at first applanation and the Ambrósio relational thickness through the horizontal meridian decreased after surgery (P < .001). The changes in deformation amplitude ratio 2.0 mm and integrated inverse radius were smaller in transepithelial PRK than femtosecond-assisted LASIK (P < .001). Using analysis of covariance, with refractive error change or corneal thickness change as a covariate, the changes in deformation amplitude ratio 2.0 mm and integrated inverse radius were smaller in transepithelial PRK than femtosecond-assisted LASIK (P < .001). CONCLUSIONS The dynamic Scheimpflug analyzer showed stable biomechanically corrected IOP measurement before and after surgery. The changes in dynamic corneal response parameters were smaller with transepithelial PRK than with femtosecond-assisted LASIK, indicating less of a biomechanical effect with transepithelial PRK.
Collapse
|
9
|
Adjustment of Spherical Equivalent Correction According to Cap Thickness for Myopic Small Incision Lenticule Extraction. J Refract Surg 2019; 35:153-160. [PMID: 30855092 DOI: 10.3928/1081597x-20190205-01] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2018] [Accepted: 02/05/2019] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the amount of spherical equivalent correction for three different cap thicknesses (120, 130, and 140 µm) during myopic small incision lenticule extraction (SMILE) and determine the association between the amount of spherical equivalent correction and several variables in each cap thickness group. METHODS In this retrospective, comparative, observational case series study, the authors compared refractive errors, keratometric values, laser setting (sphere correction, cylinder correction, spherical equivalent correction, optical zone, and cap diameter), and spherical aberration measured preoperatively and at 3 months postoperatively between three different cap thickness groups: 120 µm (n = 554), 130 µm (n = 377), and 140 µm (n = 90). Multiple linear regression analyses were used to determine the associations between the amount of spherical equivalent correction and several variables, including age, preoperative spherical equivalent, optical zone diameter, central corneal thickness, preoperative mean keratometric values, and preoperative corneal asphericity. RESULTS According to cap thickness, attempted correction is adjusted to achieve the same refractive outcomes for different cap thicknesses. There were significant differences in the amount of sphere correction and spherical equivalent correction, as well as lenticule thickness, among subgroups. Changes in keratometric values, corneal asphericity, and spherical aberration were also significantly different among subgroups (all P < .001). Changes in keratometric values, corneal asphericity, and spherical aberration significantly increased as cap thickness increased. Preoperative spherical equivalent mainly influenced the amount of spherical equivalent correction in each group. CONCLUSIONS Dioptric adjustment of spherical equivalent correction according to cap thickness is essential to obtain similar refractive outcomes in myopic SMILE procedures. [J Refract Surg. 2019;35(3):153-160.].
Collapse
|
10
|
Relationship Between Decentration and Induced Corneal Higher-Order Aberrations Following Small-Incision Lenticule Extraction Procedure. Invest Ophthalmol Vis Sci 2019; 59:2316-2324. [PMID: 29847636 DOI: 10.1167/iovs.17-23451] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To investigate the amount of lenticule decentration following small-incision lenticule extraction (SMILE) by using the Keratron Scout tangential topography difference map, and the relationship between the magnitudes of total decentration and induced corneal higher-order aberrations (HOAs). Methods This retrospective observational case series study analyzed decentration values obtained from the Keratron Scout tangential topography difference map of 360 eyes (360 patients) that underwent SMILE. Root mean square total HOAs, third order coma aberration, fourth order spherical aberration, as well as individual coefficients for vertical and horizontal coma were measured preoperatively and 3-months postoperatively. Simple linear regression analysis and piecewise regression models were used to determine the relationship between the magnitudes of total decentration and induced corneal HOAs. Results The mean total decentration distance from the corneal vertex was 0.36 ± 0.22 mm (range, 0.02-1.27 mm). There were significant differences in total HOAs, coma, vertical and horizontal comas, and spherical aberration between preoperative and 3-month postoperative assessments. Significant relationships between the magnitudes of total decentration and induced corneal HOAs were noted. Subgroup analysis according to the degree of total decentration (group I, total decentered displacement ≤0.335 mm; and group II, total decentered displacement >0.335 mm) revealed that induced changes in total HOAs, coma, vertical coma, and spherical aberration were significantly larger in group II than in group I. Conclusions A minimal degree of decentration was closely related to a smaller induction of corneal HOAs. Efforts to optimize centration are critical for achieving better surgical outcomes in SMILE.
Collapse
|
11
|
Biomechanical Properties of the Cornea Using a Dynamic Scheimpflug Analyzer in Healthy Eyes. Yonsei Med J 2018; 59:1115-1122. [PMID: 30328327 PMCID: PMC6192879 DOI: 10.3349/ymj.2018.59.9.1115] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2018] [Revised: 08/18/2018] [Accepted: 08/20/2018] [Indexed: 11/27/2022] Open
Abstract
PURPOSE To investigate biomechanical properties of the cornea using a dynamic Scheimpflug analyzer according to age. MATERIALS AND METHODS In this prospective, cross-sectional, observational study, participants underwent ophthalmic investigations including corneal biomechanical properties, keratometric values, intraocular pressure (IOP), and manifest refraction spherical equivalent (MRSE). We determined the relationship of biomechanical parameters and ocular/systemic variables (participant's age, MRSE, IOP, and mean keratometric values) by piecewise regression analysis, association of biomechanical parameters with variables by Spearman's correlation and stepwise multiple regression analyses, and reference intervals (RI) by the bootstrap method. RESULTS This study included 217 eyes of 118 participants (20-81 years of age). Piecewise regression analysis between Corvis-central corneal thickness (CCT) and participant's age revealed that the optimal cut-off value of age was 45 years. No clear breakpoints were detected between the corneal biomechanical parameters and MRSE, IOP, and mean keratometric values. Corneal velocity, deformation amplitude, radius, maximal concave power, Corvis-CCT, and Corvis-IOP exhibited correlations with IOP, regardless of age (all ages, 20-44 years, and over 44 years). With smaller deformation amplitude and corneal velocity as well as increased Corvis-IOP and Corvis-CCT, IOP became significantly increased. We provided the results of determination of confidence interval from RI data using bootstrap method in three separate age groups (all ages, 20-44 years, and over 44 years). CONCLUSION We demonstrated multiple corneal biomechanical parameters according to age, and reported that the corneal biomechanical parameters are influenced by IOP.
Collapse
|
12
|
Rotational Stability and Visual Outcomes of V4c Toric Phakic Intraocular Lenses. J Refract Surg 2018; 34:489-496. [PMID: 30001453 DOI: 10.3928/1081597x-20180521-01] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2018] [Accepted: 05/07/2018] [Indexed: 11/20/2022]
Abstract
PURPOSE To investigate the clinical outcomes and rotational stability following implantation of V4c toric implantable collamer lenses (ICLs) (STAAR Surgical Company, Monrovia, CA) and to analyze the factors that influence rotational stability. METHODS In this prospective observational case series, the authors analyzed the visual outcomes and rotational stability in 52 eyes of 52 patients immediately and 3 and 6 months after implantation. Postoperative rotation was defined as the angle between the adjusted axis and alignment axis. Central vaulting of the ICL was measured in a non-accommodative state using Visante optical coherence tomography (Carl Zeiss Meditec, Jena, Germany). Vector analysis of refractive astigmatism was performed. Regression analysis was used to investigate the association between the degree of rotation 6 months postoperatively and the associated variables. RESULTS The mean efficacy index and safety index 6 months postoperatively were 1.35 ± 0.19 and 1.38 ± 0.22, respectively. In vector analysis, the magnitude of error was -0.20 diopters (D), indicating slight undercorrection. Absolute degree of rotation was 2.81° ± 1.87° immediately after the operation and 3.75° ± 2.92° and 3.87° ± 3.07° at 3 and 6 months postoperatively, respectively (P = .009). Bonferroni-adjusted post-hoc comparison showed that the absolute degree of rotation immediately after the operation was significantly smaller than that after 3 (P = .043) and 6 (P = .023) months, with barely any change after 3 months. No explanatory variable relevant to the absolute degree of rotation was discovered. CONCLUSIONS The V4c toric ICL is predictable, safe, and effective in correcting low and high levels of astigmatism, showing relatively good postoperative rotational stability. [J Refract Surg. 2018;34(7):489-496.].
Collapse
|
13
|
Clinical Outcomes of Transepithelial Photorefractive Keratectomy According to Epithelial Thickness. J Refract Surg 2018; 34:533-540. [DOI: 10.3928/1081597x-20180618-02] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2018] [Accepted: 06/08/2018] [Indexed: 11/20/2022]
|
14
|
Comparison of the Distribution of Lenticule Decentration Following SMILE by Subjective Patient Fixation or Triple Marking Centration. J Refract Surg 2018; 34:446-452. [DOI: 10.3928/1081597x-20180517-02] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2017] [Accepted: 05/07/2018] [Indexed: 11/20/2022]
|
15
|
Clinical Outcomes of SMILE With a Triple Centration Technique and Corneal Wavefront-Guided Transepithelial PRK in High Astigmatism. J Refract Surg 2018. [PMID: 29522224 DOI: 10.3928/1081597x-20180104-03] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To comparatively investigate the clinical outcomes, vector parameters, and corneal aberrations of small incision lenticule extraction (SMILE) with a triple centration technique and corneal wavefront-guided transepithelial photorefractive keratectomy (PRK) for the correction of high astigmatism. METHODS This retrospective, comparative case series study included 89 eyes (89 patients) that received treatment for myopia with high astigmatism (≥ 2.50 diopters) using SMILE with a triple centration technique (SMILE group; 45 eyes) and corneal wavefront-guided transepithelial PRK (transepithelial PRK group; 44 eyes). Visual acuity measurement, manifest refraction, slit-lamp examination, autokeratometry, corneal topography, and evaluation of corneal wavefront aberration were performed preoperatively and at 1, 3, and 6 months after surgery. The safety, efficacy, vector parameters, and corneal aberrations at 6 months after surgery were compared between the two groups. RESULTS At 6 months after surgery, the transepithelial PRK and SMILE groups exhibited comparable mean uncorrected distance visual acuities (-0.06 ± 0.07 and -0.05 ± 0.07 logMAR, respectively), safety, efficacy, and predictability of refractive and visual outcomes. There was a slight but statistically significant difference in the correction index between the transepithelial PRK and SMILE groups (0.96 ± 0.11 and 0.91 ± 0.10, respectively). Whereas the transepithelial PRK group exhibited increased corneal spherical aberration and significantly reduced corneal coma and trefoil, no changes in aberrometric values were noted in the SMILE group. CONCLUSIONS Both SMILE with a triple centration technique and corneal wavefront-guided transepithelial PRK are effective and provide predictable outcomes for the correction of high myopic astigmatism, although slight undercorrection was observed in the SMILE group. The triple centration technique was helpful in astigmatism correction by SMILE. [J Refract Surg. 2018;34(3):156-163.].
Collapse
|
16
|
Visual rehabilitation in moderate keratoconus: combined corneal wavefront-guided transepithelial photorefractive keratectomy and high-fluence accelerated corneal collagen cross-linking after intracorneal ring segment implantation. BMC Ophthalmol 2017; 17:270. [PMID: 29284455 PMCID: PMC5746954 DOI: 10.1186/s12886-017-0666-1] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2017] [Accepted: 12/18/2017] [Indexed: 11/24/2022] Open
Abstract
Background To investigate the effects of combined corneal wavefront-guided transepithelial photorefractive keratectomy (tPRK) and accelerated corneal collagen cross-linking (CXL) after intracorneal ring segment (ICRS) implantation in patients with moderate keratoconus. Methods Medical records of 23 eyes of 23 patients undergoing combined tPRK and CXL after ICRS implantation were retrospectively analyzed. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction spherical equivalent (MRSE), corneal indices based on Scheimpflug tomography, higher-order aberrations (HOAs), and corneal biomechanical properties were evaluated before and after ICRS implantation, and at 1, 3, and 6 months after combined tPRK and CXL. Results There were significant improvements in final logMAR UDVA and logMAR CDVA, and reductions in sphere, MRSE, and all corneal indices from baseline. Significant improvements in logMAR UDVA and reductions in sphere, MRSE, maximal keratometry, keratometry at the apex, mean keratometry, and keratoconus index were noted after ICRS implantation. After tPRK and CXL, significant improvements in logMAR UDVA and logMAR CDVA, and reductions in cylinder and all corneal indices were observed. There were significant improvements in final root mean square HOAs and coma aberrations from baseline, but no changes from baseline after ICRS implantation. Significant reductions in final radius and deformation amplitude from baseline were noted. Conclusions Combined tPRK and accelerated CXL after ICRS implantation in moderate keratoconus appears to be a safe and effective treatment, providing an improvement in visual acuity, corneal indices, and HOAs. Trial registration retrospectively registered (identification no. NCT03355430). Date registered: 28/11/2017.
Collapse
|
17
|
RETRACTED: Effect of Lowering Laser Energy on the Surface Roughness of Human Corneal Lenticules in SMILE. J Refract Surg 2017; 33:617-624. [DOI: 10.3928/1081597x-20170620-02] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2017] [Accepted: 05/26/2017] [Indexed: 11/20/2022]
|
18
|
Lower Laser Energy Levels Lead to Better Visual Recovery After Small-Incision Lenticule Extraction: Prospective Randomized Clinical Trial. Am J Ophthalmol 2017; 179:159-170. [PMID: 28499707 DOI: 10.1016/j.ajo.2017.05.005] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2017] [Revised: 04/27/2017] [Accepted: 05/01/2017] [Indexed: 11/24/2022]
Abstract
PURPOSE To determine the effect of lowering laser energy on clinical outcomes in small-incision lenticule extraction (SMILE). DESIGN Prospective randomized clinical trial. METHODS A total of 151 patients (151 eyes) with moderate myopia scheduled for SMILE were included: 58 eyes received SMILE with low energy (100, 105, and 110 nJ; L-SMILE group) and 93 with conventional energy (115-150 nJ; C-SMILE group). Patients received complete ophthalmic examinations preoperatively and over 3 months postoperatively. RESULTS Uncorrected distance visual acuity (logMAR UDVA) 1 day and 1 week postoperatively was significantly better in L-SMILE than in C-SMILE (P < .001 and P = .005, respectively). There was no significant difference between the groups at 1 and 3 months. L-SMILE induced significantly fewer corneal aberrations compared with C-SMILE at 1 week and 1 month postoperatively (both P < .01), but there were no significant differences at 3 months. Though there was no difference in logMAR UDVA over the postoperative period between the 100, 105, and 110 nJ subgroups, there was a significant difference in logMAR UDVA on postoperative day 1 between L-SMILE and each subgroup in which an energy level of 115 nJ or higher was used. Furthermore, logMAR UDVA on postoperative day 1 showed a significant correlation with laser energy (r = 0.451, P < .001) and multiple linear regression analysis revealed that energy level was the only independent factor associated with logMAR UDVA on postoperative day 1 (P < .001). CONCLUSIONS SMILE using femtosecond energy of less than 115 nJ facilitates better visual acuity with less induction of corneal aberrations in the early postoperative period.
Collapse
|
19
|
Influence of Pachymetry and Intraocular Pressure on Dynamic Corneal Response Parameters in Healthy Patients. J Refract Surg 2017; 32:550-61. [PMID: 27505316 DOI: 10.3928/1081597x-20160524-01] [Citation(s) in RCA: 139] [Impact Index Per Article: 19.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2016] [Accepted: 04/14/2016] [Indexed: 01/02/2023]
Abstract
PURPOSE To evaluate the influence of pachymetry, age, and intraocular pressure in normal patients and to provide normative values for all dynamic corneal response parameters (DCRs) provided by dynamic Scheimpflug analysis. METHODS Seven hundred five healthy patients were included in this multicenter retrospective study. The biomechanical response data were analyzed to obtain normative values with their dependence on corrected and clinically validated intraocular pressure estimates developed using the finite element method (bIOP), central corneal thickness (CCT), and age, and to evaluate the influence of bIOP, CCT, and age. RESULTS The results showed that all DCRs were correlated with bIOP except deflection amplitude (DefA) ratio, highest concavity (HC) radius, and inverse concave radius. The analysis of the relationship of DCRs with CCT indicated that HC radius, inverse concave radius, deformation amplitude (DA) ratio, and DefA ratio were correlated with CCT (rho values of 0.343, -0.407, -0.444, and -0.406, respectively). The age group subanalysis revealed that primarily whole eye movement followed by DA ratio and inverse concave radius were the parameters that were most influenced by age. Finally, custom software was created to compare normative values to imported examinations. CONCLUSIONS HC radius, inverse concave radius, DA ratio, and DefA ratio were shown to be suitable parameters to evaluate in vivo corneal biomechanics due to their independence from IOP and their correlation with pachymetry and age. The creation of normative values allows the interpretation of an abnormal examination without the need to match every case with another normal patient matched for CCT and IOP. [J Refract Surg. 2016;32(8):550-561.].
Collapse
|
20
|
Comparison of Toric Foldable Iris-Fixated Phakic Intraocular Lens Implantation and Limbal Relaxing Incisions for Moderate-to-High Myopic Astigmatism. Yonsei Med J 2016; 57:1475-81. [PMID: 27593877 PMCID: PMC5011281 DOI: 10.3349/ymj.2016.57.6.1475] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2015] [Revised: 04/15/2016] [Accepted: 04/26/2016] [Indexed: 11/30/2022] Open
Abstract
PURPOSE To compare the effectiveness of toric foldable iris-fixated phakic intraocular lens (pIOL) implantation and non-toric foldable iris-fixated pIOL implantation with limbal relaxing incisions (LRIs) for correcting moderate-to-high astigmatism in myopic eyes. MATERIALS AND METHODS The medical records of 146 patients (195 eyes) with myopic astigmatism who underwent toric foldable iris-fixated pIOL implantation (toric group; 94 eyes) or non-toric foldable iris-fixated pIOL implantation with concurrent LRIs (LRI group; 101 eyes) were retrospectively reviewed. For subgroup analysis, the two groups were subdivided according to preoperative astigmatic severity [moderate, 2.00 to <3.00 diopters (D); high, 3.00-4.00 D]. Visual and astigmatic outcomes were compared 6 months postoperatively. RESULTS The uncorrected distance visual acuity was at least 20/25 in 100% and 98% of the toric and LRI group eyes, respectively. The toric group had lower mean residual cylindrical error (-0.67±0.39 D vs. -1.14±0.56 D; p<0.001) and greater mean cylindrical error change (2.17±0.56 D vs. 1.63±0.72 D; p<0.001) than the LRI group, regardless of the preoperative astigmatic severity. The mean correction index (1.10±0.16 vs. 0.72±0.24; p<0.001) and success index (0.24±0.14 vs. 0.42±0.21; p<0.001) also differed significantly between the groups. CONCLUSION Both surgical techniques considerably reduced astigmatism and had comparable visual outcomes. However, toric foldable iris-fixated pIOL implantation was more reliable for correcting moderate-to-high astigmatism in myopic eyes.
Collapse
|
21
|
Effect of Accommodation on Vaulting and Movement of Posterior Chamber Phakic Lenses in Eyes With Implantable Collamer Lenses. Am J Ophthalmol 2015; 160:710-6.e1. [PMID: 26189089 DOI: 10.1016/j.ajo.2015.07.014] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2015] [Revised: 07/09/2015] [Accepted: 07/10/2015] [Indexed: 10/23/2022]
Abstract
PURPOSE To investigate and compare vaulting and movement changes during accommodation in eyes with the V4c and V4 implantable collamer lenses (ICL). DESIGN Comparative, observational case series. METHODS The medical records of 35 eyes (18 patients) with the V4 ICL and 51 eyes (26 patients) with the V4c ICL were retrospectively examined and included in analyses. Anterior chamber depth (ACD), posterior corneal surface-to-ICL distance (endo-ICL distance), pupil size, and postoperative vaulting were evaluated using the Visante anterior chamber optical coherence tomography system. Images were taken during the nonaccommodative and accommodative states 3 months after ICL implantation. Refractive error, keratometry values, axial length, intraocular pressure, and central corneal thickness were evaluated at 3 months postoperatively. RESULTS ICL vaulting did not significantly change during accommodation in eyes with either the V4 or V4c ICL (P = .532 for V4 ICL and P = .415 for V4c ICL). However, significant reductions in ACD, endo-ICL distance, and pupil size were observed during accommodation in both groups. In eyes with a V4 ICL, the change in [Δ] ACD was 0.2 ± 0.1 mm (P < .001), Δendo-ICL distance was 0.2 ± 0.1 mm (P < .001), and Δpupil size was 0.5 ± 0.9 mm (P = .021). For eyes with the V4c ICL, ΔACD was 0.2 ± 0.2 mm (P < .001), Δendo-ICL distance was 0.2 ± 0.2 mm (P < .001), and Δpupil size was 0.8 ± 1.2 mm (P < .001). The mean reductions of each parameter were not statistically different between eyes with the V4 ICL and the V4c ICL. CONCLUSIONS Contrary to the light stimulation response, accommodation does not significantly affect ICL vaulting differently in eyes with either the V4 or V4C ICLs.
Collapse
|