1
|
Abstract
Background: Osteoid osteoma is a benign bone tumor typically inducing night pain. It has traditionally been treated with operative excision. An accurate localization and complete removal of the small lesion is difficult resulting in high recurrence rate and reoperations. Aims: The purpose of the present study was to examine the applicability of a handheld gamma probe in the intraoperative localization of an osteoid osteoma. Material and Methods: Five patients were examined and operated for osteoid osteoma. Dose of 740 MBq Technetium 99m was injected 3 hours before operation, and handheld gamma probe was used for the intraoperative detection of the lesion. Results: All patients were relieved their symptoms. A histologically confirmed, complete removal of the lesion was achieved in 4 of 5 patients. No recurrences has been seen in the follow-up of 6 years. Conclusions: The gamma probe is an useful tool in the surgical treatment of osteoid osteoma. The technique is rapid and simple resulting in more accurate excision of the small lesion.
Collapse
Affiliation(s)
- J S Kettunen
- Department of Orthopaedics and Traumatology, Kuopio University Hospital, Kuopio, Finland.
| | | | | |
Collapse
|
2
|
Mäkelä EA. [Bone tumors]. Duodecim 2002; 117:2205-14. [PMID: 12184208] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/26/2023]
Affiliation(s)
- E A Mäkelä
- Kuopion yliopistollinen sairaala Kirurgian klinikka 70210 Kuopio
| |
Collapse
|
3
|
Abstract
The classic method of open bone grafting in the treatment of un-united tibial fractures has been associated with some complications. A novel, minimally invasive, percutaneous technique of bone grafting is described. Forty-one consecutive patients with delayed union or non-union of a tibial fracture was treated with percutaneous bone grafting from 1993 to 1999. The mean age of the patients was 41 (15-86) years. Twenty-seven patients had grade I-III open fractures. The fractures had initially been treated in a cast (n=26), external fixator (n=14) or intramedullary nail (n=1). Two patients had an earlier unsuccessful Phemister-Charnley-type bone-grafting procedure for delayed union. The mean interval from injury to percutaneous bone grafting was 21 (13-66) weeks. Thirty-seven of the 41 un-united fractures healed in 13 (10-48) weeks after the percutaneous bone grafting. The mean hospital stay was 1 day. No infections, bleeding or neural complications existed. Percutaneous bone grafting appeared to be as effective as open techniques, and possessed considerable advantages. It is safe, time saving and economical, it involves minimal trauma at the fracture site and it avoids major donor site problems.
Collapse
Affiliation(s)
- J Kettunen
- Department of Orthopaedics and Traumatology, Kuopio University Hospital, 70211, Kuopio, Finland.
| | | | | | | | | |
Collapse
|
4
|
Joukainen A, Pihlajamäki H, Mäkelä EA, Ashammakhi N, Viljanen J, Pätiälä H, Kellomäki M, Törmälä P, Rokkanen P. Strength retention of self-reinforced drawn poly-L/DL-lactide 70/30 (SR-PLA70) rods and fixation properties of distal femoral osteotomies with these rods. An experimental study on rats. J Biomater Sci Polym Ed 2001; 11:1411-28. [PMID: 11261881 DOI: 10.1163/156856200744318] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Self-reinforced polylevo-dextro-lactic acid (SR-PLA) 70 composite rods, (2 mm x 26 mm) were implanted in the dorsal subcutaneus tissue of sixteen rats. Osteotomies of the distal femur were fixed with SR-PLA70 composite rods (2 mm x 15 mm) in 39 rats. The follow-up times varied from 1 week to 1 year. After sacrifice three-point bending and shear tests were performed for subcutaneously placed rods, and radiological, histological, histomorphometrical, microradiographic, and oxytetracycline-fluorescence studies of osteotomized and intact control femora were performed. At 52 weeks the shear strength and flexural modulus of the rods were 41% of the initial value, and the flexural strength was 43% of the initial value. In the osteotomies seven specimens had to be excluded due to postoperative infection or dislocation of the fragment. Six of the thirty-two evaluated osteotomies showed signs of postoperative infection. Twenty-six osteotomies healed uneventfully. No signs of inflammatory or foreign-body reaction were observed. The present investigation demonstrated that the mechanical strength and fixation properties of the SR-PLA70 rods are suitable for fixation of cancellous bone osteotomies in rats. The present article is the first report on successful application of SR-PLA70 rods for fixation of cancellous bone osteotomies studied.
Collapse
Affiliation(s)
- A Joukainen
- Department of Orthopaedics and Traumatology, Helsinki University Central Hospital, Finland
| | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Ashammakhi N, Mäkelä EA, Törmälä P, Waris T, Rokkanen P. Effect of self-reinforced polyglycolide membrane on osteogenesis: an experimental study in rats. European Journal of Plastic Surgery 2000. [DOI: 10.1007/s002380000200] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
6
|
Rokkanen PU, Böstman O, Hirvensalo E, Mäkelä EA, Partio EK, Pätiälä H, Vainionpää SI, Vihtonen K, Törmälä P. Bioabsorbable fixation in orthopaedic surgery and traumatology. Biomaterials 2000; 21:2607-13. [PMID: 11071610 DOI: 10.1016/s0142-9612(00)00128-9] [Citation(s) in RCA: 236] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Bioabsorbable internal fixation devices were introduced clinically in the treatment of fractures and osteotomies of the extremities at the Department of Orthopaedics and Traumatology, Helsinki University, in 1984. Since November 5, 1984, a total of 3200 patients were managed using bone or ligament fixation devices made of self-reinforced (matrix and fibres of the same polymer) bioabsorbable alpha-hydroxy polyesters. The devices used included cylindrical rods, screws, tacks, plugs, arrows, and wires. The most common indication for the use of bioabsorbable implants was the displaced malleolar fracture of the ankle. Transphyseal fixation with small-diameter, mainly polyglycolide pins was used in children. The postoperative clinical course was uneventful in more than 90% of the patients. The complications included bacterial wound infection in 4% and failure of fixation in 4%. In one-fifth of the latter cases, however, re-operation was not necessary. The occurrence of non-infectious foreign-body reactions two to three months postoperatively has been observed in 2% of the patients operated in the last few years with polyglycolide implants but none of the patients managed with polylactide implants. This inflammatory tissue response often required aspiration with a needle but did not influence the functional or radiologic result of the treatment. Owing to the biodegradability of these internal fixation devices, implant removal procedures were avoided. This results in financial benefits and psychological advantages. Bioabsorbable implants can also be used in open fractures and infection operations.
Collapse
Affiliation(s)
- P U Rokkanen
- Department of Orthopaedics and Traumatology, Helsinki University, Central Hospital, Finland
| | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Heino A, Naukkarinen A, Pietiläinen T, Merasto ME, Törmälä P, Pohjonen T, Mäkelä EA. Application of a self-reinforced polyglycolic acid (SR-PGA) membrane to the closure of an abdominal fascial defect in rats. J Biomed Mater Res 1999; 48:596-601. [PMID: 10490672 DOI: 10.1002/(sici)1097-4636(1999)48:5<596::aid-jbm2>3.0.co;2-s] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The suitability of a polyglycolic acid (PGA) membrane to fascial closure was tested in 40 rats. To induce collagen synthesis, a fascial strip from the vastus lateralis muscle was applied to the peritoneal side of the PGA membrane. A midline laparotomy was performed, and the incision was covered with the membrane fixed at the edges. The animals were sacrificed at 3, 6, 12, and 28 weeks, at which time macroscopical, histological, and electron microscopical findings, as well as the results of breaking force tests were evaluated. Fascial augmentation had no effect on the results. Ventral hernias were observed in 37.5% of the cases, half of which were observed after 6 weeks postoperatively. In one case, intestinal adhesions to the membrane were found. Inflammatory reaction during the follow-up was moderate and lasted up to 12 weeks. Breaking force decreased up to 6 weeks, after which it slightly increased without reaching the breaking force level of the control animals.
Collapse
Affiliation(s)
- A Heino
- Department of Surgery, Kuopio University Hospital, Kuopio, Finland.
| | | | | | | | | | | | | |
Collapse
|
8
|
Kettunen J, Mäkelä EA, Miettinen H, Nevalainen T, Heikkilä M, Pohjonen T, Törmälä P, Rokkanen P. Mechanical properties and strength retention of carbon fibre-reinforced liquid crystalline polymer (LCP/CF) composite: an experimental study on rabbits. Biomaterials 1998; 19:1219-28. [PMID: 9720885 DOI: 10.1016/s0142-9612(98)00027-1] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
A novel composite material with ultra-high flexural strength and cortical-bone-matched elastic modulus made of liquid crystalline polymer reinforced with carbon fibres (LCP/CF) is described. Cylindrical rods of 3.2 mm diameter and 50 mm length were fabricated by a preimpregnation/pultrusion method. The initial mechanical properties of the LCP/CF rods were as follows: flexural strength 448 MPa, flexural modulus 43 GPa, shear strength 164 MPa, and interlaminar shear strength 15.3 MPa. In the in vitro study the LCP/CF rods were immersed in phosphate-buffered saline of 37 degrees C for 12, 24, and 52 weeks. In the in vivo study the LCP/CF rods were implanted into the medullary cavity of both femora and subcutaneous tissue of the New Zealand White rabbits for 12, 24, and 52 weeks. The flexural strength of the LCP/CF rods at 52 weeks was 463 MPa in saline, 467 MPa in the subcutaneous tissue and 466 MPa in the medullary cavity of the femur. The flexural modulus was 44.6, 48.9 and 46.2 GPa, respectively. The corresponding shear strength values were 160, 178 and 181 MPa. We conclude that the LCP/CF is a promising material for high-load applications and the LCP/CF rods retain their initial mechanical properties in one-year follow-up in vivo and in vitro.
Collapse
Affiliation(s)
- J Kettunen
- Department of Surgery, Kuopio University Hospital, Finland
| | | | | | | | | | | | | | | |
Collapse
|
9
|
Blasier RD, Bucholz R, Cole W, Johnson LL, Mäkelä EA. Bioresorbable implants: applications in orthopaedic surgery. Instr Course Lect 1997; 46:531-46. [PMID: 9143997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
There are several new and potential uses for absorbable implants. Some will provide exciting options in the future. Ongoing animal and clinical studies will help focus future areas of development.
Collapse
Affiliation(s)
- R D Blasier
- Division of Pediatric Orthopaedics, Arkansas Children's Hospital, University of Arkansas for Medical Sciences, Little Rock, USA
| | | | | | | | | |
Collapse
|
10
|
Abstract
A new poly(L-)lactic acid (PLLA) thread was tested by applying it in fascial closures of male Wistar rats. The tissue reactions around the thread and in the fascial union, and the changes on the surface and the mechanical properties of the thread were evaluated at 1, 3, 6, 12, 28, and 52 weeks following surgery. Histologically, the extension of the general inflammatory reaction and the number of the different cell types did not markedly change during the 52-week follow-up period. The surface of the thread was intact up to 28 weeks when examined with the scanning electron microscope. At 52 weeks no thread was found. The breaking force and the stretching of the incubated PLLA thread was reduced about 20% during the first 2 weeks and it remained constant up to 6 weeks. The in vivo testing of the fascial strips closed with the PLLA thread retained their resistance against the breaking force, nearly comparable to that of the intact control fascial strips. It can be concluded that the PLLA thread is a suitable suture for wounds that require healing time of up to 28 weeks and thus need good support from the suture.
Collapse
Affiliation(s)
- A Heino
- Department of Surgery, Kuopio University Hospital, Finland
| | | | | | | | | | | |
Collapse
|
11
|
Sinisaari I, Pätiälä H, Böstman O, Mäkelä EA, Hirvensalo E, Partio EK, Törmälä P, Rokkanen P. Metallic or absorbable implants for ankle fractures: a comparative study of infections in 3,111 cases. Acta Orthop Scand 1996; 67:16-8. [PMID: 8615095 DOI: 10.3109/17453679608995602] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Absorbable fracture fixation has been in clinical use since 1984. Our study compares the infection rates and some infection parameters between metallic (2073 patients) and absorbable fracture fixation devices (1012 patients) in displaced ankle fractures. The infection rate associated with metallic fixation was 4.1%, compared with 3.2% absorbable fixation (p 0.3). The patients who had a wound infection were older when metallic fixation was used (p 0.01). They also had a bi- or trimalleolar fracture more often than did patients treated with absorbable fracture fixation, but this difference did not have a significant effect on the wound infection rate (p 0.2). The infections were mostly caused by microorganisms of the Staphylococcus species. Deep infections were equally common with both fixation methods (0.4%), but there was some variation in the bacterial spectrum.
Collapse
Affiliation(s)
- I Sinisaari
- Department of Orthopedics and Traumatology, Helsinki University Central Hospital, Finland
| | | | | | | | | | | | | | | |
Collapse
|
12
|
Sinisaari I, Pätiälä H, Böstman O, Mäkelä EA, Hirvensalo E, Partio EK, Törmälä P, Rokkanen P. Wound infections associated with absorbable or metallic devices used in the fixation of fractures, arthrodeses and osteotomies. ACTA ACUST UNITED AC 1995; 5:41-3. [DOI: 10.1007/bf02716213] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/1994] [Accepted: 12/12/1994] [Indexed: 11/24/2022]
|
13
|
Ashammakhi N, Mäkelä EA, Vihtonen K, Rokkanen P, Törmälä P. Effect of self-reinforced polyglycolide membranes on cortical bone: an experimental study on rats. J Biomed Mater Res 1995; 29:687-94. [PMID: 7593004 DOI: 10.1002/jbm.820290603] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
A self-reinforced polyglycolide (SR-PGA) membrane has been developed recently by our research group and testing of it begun. To study the behavior of this membrane and its effect on cortical bone, 93 Wistar rats were operated on. SR-PGA membrane was applied around the rats' femoral diaphyses, either over the periosteum or directly over the bone, after periosteal stripping. In a control group no membrane was applied, but the femoral periosteum was stripped away. The rats were sacrificed 1, 3, 6, 12, 24, and 30 weeks postoperatively. Radiology, histology, oxytetracycline fluorescence labeling, microradiography, and planimetry were used to determine the outcome. A fibrous tissue capsule had formed around and replaced the membrane. SR-PGA membrane had a positive effect on new bone formation. Callus was frequently seen proximally and distally to the implant. Periosteal thickening occurred whether or not SR-PGA membrane was used. PGA fibers decreased in number and diameter continuously until they vanished by 30 weeks. No infections or adverse reactions were encountered. Accordingly, SR-PGA membrane is considered to be biocompatible and applicable in the treatment of cortical bone lesions such as comminuted fractures and defects.
Collapse
Affiliation(s)
- N Ashammakhi
- Department of Orthopedics and Traumatology, Helsinki University Central Hospital, Finland
| | | | | | | | | |
Collapse
|
14
|
Ashammakhi N, Mäkelä EA, Vihtonen K, Rokkanen P, Kuisma H, Törmälä P. Strength retention of self-reinforced polyglycolide membrane: an experimental study. Biomaterials 1995; 16:135-8. [PMID: 7734647 DOI: 10.1016/0142-9612(95)98276-k] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Self-reinforced polyglycolide (SR-PGA) devices are stronger than non-reinforced ones. To study the strength retention of SR-PGA membrane, in vitro and in vivo, membranes were either immersed in distilled water at 37 degrees C, or implanted in the subcutis or around the femoral bone of rats. The SR-PGA membranes lost their strength in vitro by 6 wk, while they retained it for 15 wk in vivo due to the fibrous tissue that formed around and inside the implant (biomembrane). This is an advantage when clinical application of the membrane is being considered.
Collapse
Affiliation(s)
- N Ashammakhi
- Department of Orthopaedics and Traumatology, Helsinki University Central Hospital, Finland
| | | | | | | | | | | |
Collapse
|
15
|
Abstract
A retrospective clinical and roentgenographic review was performed on 69 consecutive cementless total hip arthroplasties that had been in situ for an average of 64.4 months (range, 57-91 months). Four patients had bilateral operations. There were 23 men and 42 women. The Lord Madreporic prosthesis (Bacneux, France) was used in 49 cases, and the Link prosthesis (Waldemar Link, Hamburg, Germany) was used in 20 cases. Preoperative diagnoses were osteoarthritis (76.8%), rheumatoid arthritis (17.4%), and miscellaneous (5.8%). At the final follow-up examination, the median hip score, assessed according to a modification of the Mayo scoring system, was 86.7 points. Seventy-eight percent of the cases had a good result, 11% were fair, and 4.7% were poor. The overall revision rate was 6.3%. No significant correlation existed between the roentgenographic and clinical findings. Subsidence of the femoral component is not a definitive hallmark of loosening in the midrange interval, that is, between 2 and 5 years. The cementless hip arthroplasty is suitable for patients with rheumatoid arthritis.
Collapse
Affiliation(s)
- I A Lautiainen
- Department of Orthopaedic Surgery, Kuopio University Hospital, Finland
| | | | | |
Collapse
|
16
|
Ashammakhi N, Mäkelä EA, Vihtonen K, Rokkanen P, Törmälä P. The effect of absorbable self-reinforced polyglycolide membrane on metaphyseal bone. An experimental study on rats. Ann Chir Gynaecol 1994; 83:328-334. [PMID: 7733617] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
The effect of self-reinforced polyglycolide (SR-PGA) absorbable membranes on metaphyseal bone was studied in eighty-seven rats. SR-PGA membranes, 0.15 mm thick, were implanted on the femoral metaphyseal bone: on the periosteum, and directly on bone after periosteal stripping. In a control group, only periosteal stripping was performed. The rats were killed after 1, 3, 6, 12 and 24 weeks. Fibrous tissue formation around the implant, periosteal thickening and new bone formation occurred more extensively when SR-PGA membranes were implanted directly on bone after periosteal stripping. Fibrous tissue invaded the membranes. At twenty-four weeks, few fibre remnants were found embedded in a rim of fibrous tissue. No locally adverse reactions were recorded. Polyglycolide (PGA) appeared to have a positive inductive effect on new bone formation.
Collapse
Affiliation(s)
- N Ashammakhi
- Department of Orthopaedics and Traumatology, Helsinki University Central Hospital, Finland
| | | | | | | | | |
Collapse
|
17
|
Böstman O, Mäkelä EA, Södergård J, Hirvensalo E, Törmälä P, Rokkanen P. Absorbable polyglycolide pins in internal fixation of fractures in children. J Pediatr Orthop 1993; 13:242-5. [PMID: 8384640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Absorbable implants made of synthetic biodegradable polymers were recently introduced clinically in internal fixation of fractures. In this prospective study of 71 pediatric patients with a variety of displaced physeal or nonphyseal fractures, self-reinforced polyglycolide pins 1.5 or 2.0 mm in diameter were used instead of Kirschner wires to fix the fragments. The majority of patients (45 children) had a fracture affecting the distal humerus. Mean age of the patients was 9.8 years (range 2-15 years). Follow-up averaged 15.8 months. In 62 patients (87%), an exact reduction of the fracture could be maintained until union. Among the remaining patients, six had minor inaccuracies or redisplacements of the fracture position, but in three patients with supracondylar fractures of the humerus breakage of the pins resulted in a severe redisplacement that necessitated a change in treatment method. With the exception of supracondylar fractures of the humerus, these preliminary results of polyglycolide pin fixation were deemed satisfactory. The fundamental advantage of this method is that no hardware removal procedures are required.
Collapse
Affiliation(s)
- O Böstman
- Department of Orthopaedics and Traumatology, University Central Hospital, Helsinki, Finland
| | | | | | | | | | | |
Collapse
|
18
|
Mäkelä EA, Böstman O, Kekomäki M, Södergård J, Vainio J, Törmälä P, Rokkanen P. Biodegradable fixation of distal humeral physeal fractures. Clin Orthop Relat Res 1992:237-43. [PMID: 1327604] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Polyglycolic acid (PGA) has been used worldwide as a biodegradable suture material since 1970. Biodegradable polyglycolide implants were introduced in osteofixation of cancellous bone fractures in 1985. From September 1987 to September 1989, 19 consecutive children with physeal fractures of the distal humerus necessitating open reduction and internal fixation were treated by transphyseal biodegradable fixation using 1.5 x 60-mm2 self-reinforced polyglycolide (SR-PGA) pins. Included were nine displaced fractures of the lateral humeral condyle, five severe avulsions of the medial epicondyle of the humerus, four displaced fractures of the humeral capitellum, and one intraarticular fracture of the medial condyle of the humerus. After accurate reduction, two smooth Kirschner pins 1.5 mm in diameter were introduced across the growth plate for temporary fixation. The metallic pins then were removed one by one and subsequently replaced with the cylindrical SR-PGA pins 1.5 mm in diameter. After operation, a padded plaster splint was worn for four weeks. Neither secondary displacement nor signs of growth disturbance were seen during the 26-month follow-up time (mean, 17.2 months). Not only the reduction of the costs but also the psychological aspects should be considered when dealing with biodegradable fixation of physeal fractures in children. Transphyseal biodegradable fixation has established itself as a procedure of choice for handling simple physeal fractures.
Collapse
Affiliation(s)
- E A Mäkelä
- Department of Orthopaedics, Kuopio University Hospital, Finland
| | | | | | | | | | | | | |
Collapse
|
19
|
Partio EK, Merikanto J, Heikkilä JT, Ylinen P, Mäkelä EA, Vainio J, Törmälä P, Rokkanen P. Totally absorbable screws in fixation of subtalar extra articular arthrodesis in children with spastic neuromuscular disease: preliminary report of a randomized prospective study of fourteen arthrodeses fixed with absorbable or metallic screws. J Pediatr Orthop 1992; 12:646-50. [PMID: 1517428] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Seven patients with spastic neuromuscular disease and severe hindfoot valgus deformity were treated by subtalar arthrodesis. Arthrodesis was performed in both feet at the same operation and fixed on one side with a self-reinforced poly-L-lactide (SR-PLLA) screw, and with a standard AO screw on the other side. The functional status state was improved, and radiographic union of the arthrodesis occurred in all feet. The radiograph showed better solid fusion in five feet treated with PLLA screws, similar fusion in both sides in one patient, and one slower fusion in the side treated initially with a PLLA screw. Totally absorbable SR-PLLA screws appear to be firm enough for fixation of subtalar extraarticular arthrodesis in children.
Collapse
Affiliation(s)
- E K Partio
- Department of Surgery and Orthopaedics, Children's Hospital, Helsinki University Central Hospital, Finland
| | | | | | | | | | | | | | | |
Collapse
|
20
|
Rokkanen P, Böstman O, Hirvensalo E, Mäkelä EA, Partio E, Pätiälä H, Vainionpää S, Vihtonen K, Törmälä P. Utilisation des implants biodégradables dans le traitement chirurgical des fractures et au cours des ostéotomies. ACTA ACUST UNITED AC 1992. [DOI: 10.1007/bf01742423] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
21
|
Abstract
Electrical stimulation has been used as treatment for nonunions of fractures since the early 1950s, with a reported success rate of 80-85%. We report a case of nonunion of a tibial fracture below a revised total knee prosthesis treated with a capacitively coupled electrical field. After 3 months of treatment, consolidation of this difficult fracture was evident with abundant callus formation.
Collapse
Affiliation(s)
- E A Mäkelä
- Department of Orthopaedics and Traumatology, Kuopio University Central Hospital, Finland
| |
Collapse
|
22
|
Miettinen H, Mäkelä EA, Vainio J, Rokkanen P, Törmälä P. The effect of an intramedullary biodegradable self-reinforced polyglycolic acid implant on tubular bone. An experimental study on growing dogs. J Biomater Sci Polym Ed 1992; 3:435-42. [PMID: 1329935 DOI: 10.1163/156856292x00411] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
The purpose of this study was to examine the effects of intramedullary self-reinforced polyglycolic acid (SR-PGA) implant to the femoral bone growth in a growing dog by using radiographic, microradiographic, oxytetracycline-fluorescence, histological, polariscopical and histomorphometric studies. Intramedullary reaming and SR-PGA implant did not cause any longitudinal overgrowth phenomenon, but resulted in a slight increase in femoral neck-angle. The bone histology showed normal features and blood cell counts were within normal limits.
Collapse
Affiliation(s)
- H Miettinen
- Department of Surgery, Kuopio University Hospital, Finland
| | | | | | | | | |
Collapse
|
23
|
Miettinen H, Mäkelä EA, Vainio J, Rokkanen P, Törmälä P. The effect of an intramedullary self-reinforced poly-L-lactide (SR-PLLA) implant on growing bone with special reference to fixation properties. An experimental study on growing rabbits. J Biomater Sci Polym Ed 1992; 3:443-50. [PMID: 1419973 DOI: 10.1163/156856292x00420] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Polylactic acid (PLA) is a synthetic biodegradable material. The self-reinforced implants made of poly-L-lactic acid (SR-PLLA) were manufactured of biodegradable polymeric matrix reinforced with fibres of the same material. The purpose of this study was to find out the effect of an intramedullary SR-PLLA implant on growing bone and its applicability to the fixation of a femoral shaft osteotomy in a growing rabbit. In seven rabbits 6 weeks of age a SR-PLLA implant 2.0 mm in diameter and 50 mm in length was introduced into the intramedullary cavity of the right femur. A proximal femoral shaft osteotomy of the right femur was made in another ten 6-weeks-old rabbits. After accurate reduction, fixation of the osteotomy was achieved with an intramedullary 2.0 mm by 50 mm SR-PLLA-rod. The follow-up times were 6 and 28 weeks. An intramedullary SR-PLLA-rod neither caused any disturbance of the bone growth nor abnormalities of the peripheral blood cell counts. Solid union of the osteotomy was seen in six weeks after fixation with SR-PLLA implant.
Collapse
Affiliation(s)
- H Miettinen
- Department of Surgery, Kuopio University Hospital, Finland
| | | | | | | | | |
Collapse
|
24
|
Abstract
220 operations in 211 hands in 160 consecutive patients suffering from Dupuytren's contracture were performed from 1976 through 1984 at the Kuopio University Central Hospital in Finland. 179 operations were carried out as day cases. The mean follow-up was 3.2 years. Sub-total fasciectomy resulted in good immediate and long-term improvement in 86% of patients. The recurrence rate was 27%. Surgical treatment of Dupuytren's contracture was well-suited to day surgery. A properly planned follow-up programme is suggested because of the relatively high rate of recurrence, which usually appeared within two years after operation.
Collapse
Affiliation(s)
- E A Mäkelä
- Department of Surgery, Kuopio University Central Hospital, Finland
| | | | | | | | | |
Collapse
|
25
|
Mäkelä EA, Miettinen H, Vainio J. [Intramedullary nailing of tubular bones with resorbable implants. An animal experiment study with growing dogs]. Aktuelle Traumatol 1990; 20:34-6. [PMID: 1969693] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Subtrochanteric osteotomy of the right femur was made in 8 Beagle-dogs 12 weeks of age. After accurate reduction the fixation of the osteotomy was achieved with an intramedullary self-reinforced polyglycolic acid rod. At the follow-up interval of 12 weeks an uncomplicated healing of osteotomy was seen without any growth disturbance. The SR-biodegradable PGA rods provided sufficient stability for rapid healing of subtrochanteric femoral osteotomy in growing dogs.
Collapse
Affiliation(s)
- E A Mäkelä
- Abteilung für Chirurgie des Universitätskrankenhauses Kuopio, Finnland
| | | | | |
Collapse
|
26
|
Mäkelä EA, Vainionpää S, Vihtonen K, Mero M, Laiho J, Törmälä P, Rokkanen P. Healing of physeal fracture after fixation with biodegradable self-reinforced polyglycolic acid pins. An experimental study on growing rabbits. Clin Mater 1989; 5:1-12. [PMID: 10149949 DOI: 10.1016/0267-6605(90)90067-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Physeal fractures occur at a frequency of 15% of all long bone fractures in children. Undisturbed continued bone growth is the main goal of the treatment of these fractures. After the operative reduction and fixation, whenever needed, a second operation for the removal of the pins is inevitable. The purpose of this study was to develop a biodegradable fixation device for transphyseal fracture fixation, abolishing the need of removal operation. Epiphyseal separation of the distal femoral physis was made on the right side in 18 five-week-old rabbits. The fixation of the physeal fracture was made with two self-reinforced polyglycolic acid (SR-PGA) pins 1mm in nominal diameter and 25mm in length. The follow-up times were 3, 6, 12, 24, and 28 weeks. The distal femoral growth-plate of both femurs was analyzed by radiographic, microradiographic, oxytetracycline-fluorescence, histological and histomorphometric studies. Histomorphometric studies showed normal features of growth. Two growth-plate-penetrating transcondylar SR-PGA implants, of 1mm in diameter, provided sufficient stability for the fixation of a distal femoral physeal fracture in a growing rabbit, and did not cause any growth disturbance.
Collapse
Affiliation(s)
- E A Mäkelä
- Department of Orthopaedics and Traumatology, Helsinki University Central Hospital, Finland
| | | | | | | | | | | | | |
Collapse
|
27
|
Affiliation(s)
- O Böstman
- Department of Orthopaedics and Traumatology, Helsinki University Central Hospital, Finland
| | | | | | | |
Collapse
|
28
|
Mäkelä EA, Vainionpää S, Vihtonen K, Mero M, Helevirta P, Törmälä P, Rokkanen P. The effect of a penetrating biodegradable implant on the growth plate. An experimental study on growing rabbits with special reference to polydioxanone. Clin Orthop Relat Res 1989:300-8. [PMID: 2494011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
This study examined the fate of a biodegradable polydioxanone (PDS) implant in growing bone in rabbits. In 20 immature rabbits, a PDS rod 2.0 mm in diameter and 25 mm in length was driven into a drill hole of equal bore in the intercondylar portion of the right femur across the central portion of the growth plate. In another 25 immature rabbits, a PDS rod 3.2 mm in diameter and 25 mm in length was driven into a corresponding drill hole using the same technique. The follow-up intervals were three, six, 12, 24, and 36 weeks. The distal femoral growth plates of both femora were analyzed by roentgenographic, microroentgenographic, oxytetracycline-fluorescence, histologic, and histomorphometric studies. Histomorphometric studies showed clear changes at the site of injury and appeared to be an excellent means of providing an exact numerical description of the different cellular areas of the growth plate in experimental studies. A transphyseal PDS implant 2.0 mm in diameter did not cause any permanent growth disturbance of the femur in a growing rabbit. An implant 3.2 mm in diameter caused a growth disturbance similar to a drill hole of equal bore.
Collapse
Affiliation(s)
- E A Mäkelä
- Department of Orthopaedics and Traumatology, Helsinki University Central Hospital, Finland
| | | | | | | | | | | | | |
Collapse
|
29
|
Mäkelä EA, Vainionpää S, Vihtonen K, Mero M, Rokkanen P. The effect of trauma to the lower femoral epiphyseal plate. An experimental study in rabbits. J Bone Joint Surg Br 1988; 70:187-91. [PMID: 3346285 DOI: 10.1302/0301-620x.70b2.3346285] [Citation(s) in RCA: 116] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Forty-four rabbits were operated on when five weeks old; in one group a 2 mm drill-hole was made in the intercondylar portion of the right femur across the central portion of the growth plate up to the diaphysis, while in the other group a similar drill-hole of 3.2 mm was made. At 3, 6, 12 and 24 weeks after operation, specimens from the growth plates of both femora were analysed using radiographic, microradiographic, histological and histomorphometric techniques. It was found that destruction of 7% of the cross-sectional area of the growth plate caused permanent growth disturbance and shortening of the femur.
Collapse
Affiliation(s)
- E A Mäkelä
- Department of Orthopaedics and Traumatology, Helsinki University Central Hospital, Finland
| | | | | | | | | |
Collapse
|
30
|
Mäkelä EA, Vainionpää S, Vihtonen K, Mero M, Laiho J, Törmälä P, Rokkanen P. The effect of a penetrating biodegradable implant on the epiphyseal plate: an experimental study on growing rabbits with special regard to polyglactin 910. J Pediatr Orthop 1987; 7:415-20. [PMID: 3611337 DOI: 10.1097/01241398-198707000-00007] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
A polyglactin 910 rod 3.2 mm in diameter and 25 mm in length was driven in a drill hole in the intercondylar portion of the right femur across the central portion of the growth plate in 20 5-week-old rabbits. The follow-up times were 3, 6, 12, and 24 weeks. The distal femoral growth plates of both femurs were analyzed by radiographic, microradiographic, and oxytetracycline fluorescence, histological, and histomorphometric studies. Histomorphometric studies showed clear changes at injury site and appeared to be an excellent means of exact numerical description of the different cellular areas of the growth plate. Six weeks after implantation, a polyglactin 910 implant resulted in a growth disturbance similar to that of a drill hole of equal bore.
Collapse
|