1
|
Benchmarking glycoform-resolved affinity separation - mass spectrometry assays for studying FcγRIIIa binding. Front Immunol 2024; 15:1347871. [PMID: 38469305 PMCID: PMC10925690 DOI: 10.3389/fimmu.2024.1347871] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Accepted: 02/05/2024] [Indexed: 03/13/2024] Open
Abstract
The antibody- FcγRIIIa interaction triggers key immunological responses such as antibody dependent cellular cytotoxicity (ADCC), making it highly important for therapeutic mAbs. Due to the direct glycan-glycan interaction with FcγRIIIa receptor, differences in antibody glycosylation can drastically influence the binding affinity. Understanding the differential binding of mAb glycoforms is a very important, yet challenging task due to the co-existence of multiple glycoforms in a sample. Affinity liquid chromatography (AC) and affinity capillary electrophoresis (ACE) hyphenated with mass spectrometry (MS) can provide glycoform-resolved affinity profiles of proteins based on their differences in either dissociation (AC) or equilibrium (ACE) constants. To cross-validate the affinity ranking provided by these complementary novel approaches, both techniques were benchmarked using the same FcγRIIIa constructs. Both approaches were able to assess the mAb - FcγRIIIa interaction in a glycoform selective manner and showed a clear increase in binding for fully versus hemi-fucosylated mAbs. Also, other features, such as increasing affinity with elevated galactosylation or the binding affinity for high mannose glycoforms were consistent. We further applied these approaches to assess the binding towards the F158 allotype of FcγRIIIa, which was not reported before. The FcγRIIIa F158 allotype showed a very similar profile compared to the V158 receptor with the strongest increase in binding due to afucosylation and only a slight increase in binding with additional galactosylation. Both techniques showed a decrease of the binding affinity for high mannose glycoforms for FcγRIIIa F158 compared to the V158 variant. Overall, both approaches provided very comparable results in line with orthogonal methods proving the capabilities of separation-based affinity approaches to study FcγR binding of antibody glycoforms.
Collapse
|
2
|
A robust nanoscale RP HPLC-MS approach for sensitive Fc proteoform profiling of IgG allotypes. Anal Chim Acta 2023; 1279:341795. [PMID: 37827688 DOI: 10.1016/j.aca.2023.341795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 08/30/2023] [Accepted: 09/06/2023] [Indexed: 10/14/2023]
Abstract
The conserved region (Fc) of IgG antibodies dictates the interactions with designated receptors thus defining the immunological effector functions of IgG. Amino acid sequence variations in the Fc, recognized as subclasses and allotypes, as well as post-translational modifications (PTMs) modulate these interactions. Yet, the high similarity of Fc sequences hinders allotype-specific PTM analysis by state-of-the-art bottom-up methods and current subunit approaches lack sensitivity and face co-elution of near-isobaric allotypes. To circumvent these shortcomings, we present a nanoscale reversed-phase (RP) HPLC-MS workflow of intact Fc subunits for comprehensive characterization of Fc proteoforms in an allotype- and subclass-specific manner. Polyclonal IgGs were purified from individuals followed by enzymatic digestion releasing single chain Fc subunits (Fc/2) that were directly subjected to analysis. Chromatographic conditions were optimized to separate Fc/2 subunits of near-isobaric allotypes and subclasses allowing allotype and proteoform identification and quantification across all four IgG subclasses. The workflow was complemented by a semi-automated data analysis pipeline based on the open-source software Skyline followed by post-processing in R. The approach revealed pronounced differences in Fc glycosylation between donors, besides inter-subclass and inter-allotype variability within donors. Notably, partial occupancy of the N-glycosylation site in the CH3 domain of IgG3 was observed that is generally neglected by established approaches. The described method was benchmarked across several hundred runs and showed good precision and robustness. This methodology represents a first mature Fc subunit profiling approach allowing truly subclass- and allotype-specific Fc proteoform characterization beyond established approaches. The comprehensive information obtained paired with the high sensitivity provided by the miniaturization of the approach guarantees applicability to a broad range of research questions including clinically relevant (auto)antibody characterization or pharmacokinetics assessment of therapeutic IgGs.
Collapse
|
3
|
Dopant-enriched nitrogen gas to boost ionization of glycoproteins analyzed with native liquid chromatography coupled to nano-electrospray ionization. Anal Chim Acta 2023; 1265:341271. [PMID: 37230565 DOI: 10.1016/j.aca.2023.341271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Revised: 03/27/2023] [Accepted: 04/23/2023] [Indexed: 05/27/2023]
Abstract
Proteins carry a plethora of post-translational modifications (PTMs), such as glycosylation or phosphorylation, which may affect stability and activity. Analytical strategies are needed to investigate these PTMs in their native state to determine the link between structure and function. The coupling of native separation techniques with mass spectrometry (MS) has emerged as a powerful tool for in-depth protein characterization. Yet obtaining high ionization efficiency still can be challenging. Here, we explored the potential of dopant-enriched nitrogen (DEN) gas to improve nano-electrospray ionization (nano-ESI)-MS of native proteins after anion exchange chromatography. The dopant gas was enriched with different dopants (acetonitrile, methanol, and isopropanol) and the effects were compared with the use of solely nitrogen gas for six proteins covering a wide range of physicochemical properties. The use of DEN gas resulted generally in lower charge states, independent of the selected dopant. Moreover, less adduct formation was observed, particularly for the acetonitrile-enriched nitrogen gas. Importantly, striking differences in MS signal intensity and spectral quality were observed for extensively glycosylated proteins, where isopropanol- and methanol-enriched nitrogen appeared to be most beneficial. Altogether, the use of DEN gas improved nano-ESI of native glycoproteins and increased spectral quality for highly glycosylated proteins that normally suffer from low ionization efficiency.
Collapse
|
4
|
Reversed Phase-Liquid Chromatography for Recombinant AAV Genome Integrity Assessment. Anal Chem 2023. [PMID: 37219094 DOI: 10.1021/acs.analchem.3c00222] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
After decades of research, gene therapy products have reached market maturity in recent years. Recombinant adeno-associated viruses (rAAVs) are one of the most promising gene delivery vehicles and are currently under intense scientific investigation. These next-generation medicines remain very challenging when it comes to designing appropriate analytical techniques for quality control. One critical quality attribute is the integrity of ssDNA incorporated in these vectors. The genome is the active compound driving rAAV therapy and therefore requires proper assessment and quality control. Current techniques for rAAV genome characterization include next-generation sequencing, quantitative polymerase chain reaction, analytical ultracentrifugation (AUC), and capillary gel electrophoresis (CGE), yet each of them presents their limitations or lack of user-friendliness. In this work, we demonstrate for the first time the potential of ion pairing-reverse phase-liquid chromatography (IP-RP-LC) to characterize the integrity of rAAV genomes. The obtained results were supported by two orthogonal techniques, AUC and CGE. IP-RP-LC can be performed above DNA melting temperatures, avoiding the detection of secondary DNA isoforms, and does not require the use of dyes due to UV detection. We demonstrate that this technique is suitable for batch comparability, different rAAV serotypes (AAV2 and AAV8), internal vs external (inside vs outside the capsid) DNA analysis, and contaminated samples. Overall, it is exceptionally user-friendly, needs limited sample preparation, has high reproducibility, and permits fractionation for further peak characterization. All of these factors add significant value of IP-RP-LC to the analytical toolbox of rAAV genome assessment.
Collapse
|
5
|
Software-Assisted Data Processing Workflow for Intact Glycoprotein Mass Spectrometry. J Proteome Res 2023; 22:1367-1376. [PMID: 36857466 PMCID: PMC10088042 DOI: 10.1021/acs.jproteome.2c00762] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/03/2023]
Abstract
Intact protein analysis by mass spectrometry is important for several applications such as assessing post-translational modifications and biotransformation. In particular, intact protein analysis allows the detection of proteoforms that are commonly missed by other approaches such as proteolytic digestion followed by bottom-up analysis. Two quantification methods are mainly used for intact protein data quantification, namely the extracted ion and deconvolution approaches. However, a consensus with regard to a single best practice for intact protein data processing is lacking. Furthermore, many data processing tools are not fit-for-purpose and, as a result, the analysis of intact proteins is laborious and lacks the throughput required to be implemented for the analysis of clinical cohorts. Therefore, in this study, we investigated the application of a software-assisted data analysis and processing workflow in order to streamline intact protein integration, annotation, and quantification via deconvolution. In addition, the assessment of orthogonal data sets generated via middle-up and bottom-up analysis enabled the cross-validation of cleavage proteoform assignments present in seminal prostate-specific antigen (PSA). Furthermore, deconvolution quantification of PSA from patients' urine revealed results that were comparable with manually performed quantification based on extracted ion electropherograms. Overall, the presented workflow allows fast and efficient processing of intact protein data. The raw data is available on MassIVE using the identifier MSV000086699.
Collapse
|
6
|
Online Collision-Induced Unfolding of Therapeutic Monoclonal Antibody Glyco-Variants through Direct Hyphenation of Cation Exchange Chromatography with Native Ion Mobility-Mass Spectrometry. Anal Chem 2023; 95:3932-3939. [PMID: 36791123 PMCID: PMC9979139 DOI: 10.1021/acs.analchem.2c03163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023]
Abstract
Post-translational modifications (PTMs) not only substantially increase structural heterogeneity of proteins but can also alter the conformation or even biological functions. Monitoring of these PTMs is particularly important for therapeutic products, including monoclonal antibodies (mAbs), since their efficacy and safety may depend on the PTM profile. Innovative analytical strategies should be developed to map these PTMs as well as explore possible induced conformational changes. Cation-exchange chromatography (CEX) coupled with native mass spectrometry has already emerged as a valuable asset for the characterization of mAb charge variants. Nevertheless, questions regarding protein conformation cannot be explored using this approach. Thus, we have combined CEX separation with collision-induced unfolding (CIU) experiments to monitor the unfolding pattern of separated mAbs and thereby pick up subtle conformational differences without impairing the CEX resolution. Using this novel strategy, only four CEX-CIU runs had to be recorded for a complete CIU fingerprint either at the intact mAb level or after enzymatic digestion at the mAb subunit level. As a proof of concept, CEX-CIU was first used for an isobaric mAb mixture to highlight the possibility to acquire individual CIU fingerprints of CEX-separated species without compromising CEX separation performances. CEX-CIU was next successfully applied to conformational characterization of mAb glyco-variants, in order to derive glycoform-specific information on the gas-phase unfolding, and CIU patterns of Fc fragments, revealing increased resistance of sialylated glycoforms against gas-phase unfolding. Altogether, we demonstrated the possibilities and benefits of combining CEX with CIU for in-depth characterization of mAb glycoforms, paving the way for linking conformational changes and resistance to gas-phase unfolding charge variants.
Collapse
|
7
|
Affinity capillary electrophoresis – mass spectrometry permits direct binding assessment of IgG and FcγRIIa in a glycoform-resolved manner. Front Immunol 2022; 13:980291. [PMID: 36159782 PMCID: PMC9494200 DOI: 10.3389/fimmu.2022.980291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Accepted: 08/12/2022] [Indexed: 11/13/2022] Open
Abstract
The impact of antibody glycoforms on FcγRIIa activation and immune responses is poorly understood. Yet, glycoform binding assessment remains one of the major analytical challenges requiring long enrichment or glycoengineering steps. Here, we developed and applied an affinity capillary electrophoresis-mass spectrometry approach to selectively assess the binding of different antibody glycoforms to the FcγIIa receptor without the need of glycoengineering. The approach required only low microgram amounts of antibody and receptor and enables assessing the binding of high and low-abundance glycoforms. The approach indicated clear differences in binging between doubly-, hemi-glycosylated and non-glycosylated antibodies as well as for mutated (Leu234Ala, Leu235Ala – Pro329-Gly (LALA-PG)) IgG1 antibodies silenced for Fcγ binding. The LALA-PG mutated antibody showed no binding to the FcγIIa receptor (excluding potential non-specific binding effects) while the non-glycosylated IgG1 showed a strongly reduced, but still minor binding. The highest binding affinity was for the antibody carrying two complex-type glycans. Man5 glycans resulted in decreased binding compared to complex-type glycans, with the lowest binding for the IgG containing two Man5. For complex-type glycans, galactosylation showed a subtle increase in binding to the FcγIIa receptor, and sialylation showed an increase in binding for lower sialylated species. Fucosylation did not influence binding to the FcγIIa receptor. Finally, the assay was evaluated for the two variants of the FcγRIIa receptor (allotypes H131 and R131) showing highly comparable glycoform selectivity. Overall, the proposed approach allows the direct comparison of binding affinities of different antibody species in mixtures promising a fast establishment of their structure-function relationships.
Collapse
|
8
|
Glycan and Protein Analysis of Glycoengineered Bacterial E. coli Vaccines by MALDI-in-Source Decay FT-ICR Mass Spectrometry. Anal Chem 2022; 94:4979-4987. [PMID: 35293727 PMCID: PMC8969423 DOI: 10.1021/acs.analchem.1c04690] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
![]()
Bacterial glycoconjugate
vaccines have a major role in preventing
microbial infections. Immunogenic bacterial glycans, such as O-antigen
polysaccharides, can be recombinantly expressed and combined with
specific carrier proteins to produce effective vaccines. O-Antigen
polysaccharides are typically polydisperse, and carrier proteins can
have multiple glycosylation sites. Consequently, recombinant glycoconjugate
vaccines have a high structural heterogeneity, making their characterization
challenging. Since development and quality control processes rely
on such characterization, novel strategies are needed for faster and
informative analysis. Here, we present a novel approach employing
minimal sample preparation and ultrahigh-resolution mass spectrometry
analysis for protein terminal sequencing and characterization of the
oligosaccharide repeat units of bacterial glycoconjugate vaccines.
Three glycoconjugate vaccine candidates, obtained from the bioconjugation
of the O-antigen polysaccharides from E. coli serotypes
O2, O6A, and O25B with the genetically detoxified exotoxin A from Pseudomonas aeruginosa, were analyzed by MALDI-in-source
decay (ISD) FT-ICR MS. Protein and glycan ISD fragment ions were selectively
detected using 1,5-diaminonaphtalene and a 2,5-dihydroxybenzoic acid/2-hydroxy-5-methoxybenzoic
acid mixture (super-DHB) as a MALDI matrix, respectively. The analysis
of protein fragments required the absence of salts in the samples,
while the presence of salt was key for the detection of sodiated glycan
fragments. MS/MS analysis of O-antigen ISD fragments allowed for the
detection of specific repeat unit signatures. The developed strategy
requires minute sample amounts, avoids the use of chemical derivatizations,
and comes with minimal hands-on time allowing for fast corroboration
of key structural features of bacterial glycoconjugate vaccines during
early- and late-stage development.
Collapse
|
9
|
Native Liquid Chromatography and Mass Spectrometry to Structurally and Functionally Characterize Endo-Xylanase Proteoforms. Int J Mol Sci 2022; 23:ijms23031307. [PMID: 35163230 PMCID: PMC8835838 DOI: 10.3390/ijms23031307] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Revised: 01/17/2022] [Accepted: 01/21/2022] [Indexed: 12/16/2022] Open
Abstract
Xylanases are of great value in various industries, including paper, food, and biorefinery. Due to their biotechnological production, these enzymes can contain a variety of post-translational modifications, which may have a profound effect on protein function. Understanding the structure–function relationship can guide the development of products with optimal performance. We have developed a workflow for the structural and functional characterization of an endo-1,4-β-xylanase (ENDO-I) produced by Aspergillus niger with and without applying thermal stress. This workflow relies on orthogonal native separation techniques to resolve proteoforms. Mass spectrometry and activity assays of separated proteoforms permitted the establishment of structure–function relationships. The separation conditions were focus on balancing efficient separation and protein functionality. We employed size exclusion chromatography (SEC) to separate ENDO-I from other co-expressed proteins. Charge variants were investigated with ion exchange chromatography (IEX) and revealed the presence of low abundant glycated variants in the temperature-stressed material. To obtain better insights into the effect on glycation on function, we enriched for these species using boronate affinity chromatography (BAC). The activity measurements showed lower activity of glycated species compared to the non-modified enzyme. Altogether, this workflow allowed in-depth structural and functional characterization of ENDO-I proteoforms.
Collapse
|
10
|
Assessment of Macro- and Microheterogeneity of Monoclonal Antibodies Using Capillary Zone Electrophoresis Hyphenated with Mass Spectrometry. Methods Mol Biol 2022; 2531:125-142. [PMID: 35941483 DOI: 10.1007/978-1-0716-2493-7_9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
This chapter focuses on the application of capillary zone electrophoresis hyphenated with mass spectrometry (CZE-MS) for the characterization of monoclonal antibodies (mAbs). mAbs are complex molecules comprising different glycoforms and many other posttranslational modifications. In addition to this inherent microheterogeneity, misassembling of antibodies can take place during production contributing to their macroheterogeneity. CZE-MS is a versatile and powerful technique which has demonstrated high potential for the assessment of both micro- and macroheterogeneity of mAbs. In this chapter, technical and practical considerations for the characterization of mAbs by CZE-MS are described. CE-MS interfacing, capillary coatings for the prevention of mAb adsorption, and sample preparation considerations are covered in detail. The assessment of the macro- and microheterogeneity is discussed and exemplified through three different approaches involving analysis of intact, enzymatically digested, and reduced antibodies. The examples also illustrate the use of two commercially available interfacing techniques (i.e., sheath liquid and sheathless) as well as different types of capillary coatings (positively charged and neutral coatings).
Collapse
|
11
|
Affinity Capillary Electrophoresis-Mass Spectrometry as a Tool to Unravel Proteoform-Specific Antibody-Receptor Interactions. Anal Chem 2021; 93:15133-15141. [PMID: 34739220 PMCID: PMC8600502 DOI: 10.1021/acs.analchem.1c03560] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Monoclonal antibody (mAb) pharmaceuticals consist of a plethora of different proteoforms with different functional characteristics, including pharmacokinetics and pharmacodynamics, requiring their individual assessment. Current binding techniques do not distinguish between coexisting proteoforms requiring tedious production of enriched proteoforms. Here, we have developed an approach based on mobility shift-affinity capillary electrophoresis-mass spectrometry (ACE-MS), which permitted us to determine the binding of coexisting mAb proteoforms to Fc receptors (FcRs). For high-sensitivity MS analysis, we used a sheathless interface providing adequate mAb sensitivity allowing functional characterization of mAbs with a high sensitivity and dynamic range. As a model system, we focused on the interaction with the neonatal FcR (FcRn), which determines the half-life of mAbs. Depending on the oxidation status, proteoforms exhibited different electrophoretic mobility shifts in the presence of FcRn, which could be used to determine their affinity. We confirmed the decrease of the FcRn affinity with antibody oxidation and observed a minor glycosylation effect, with higher affinities for galactosylated glycoforms. Next to relative binding, the approach permits the determination of individual KD values in solution resulting in values of 422 and 139 nM for double-oxidized and non-oxidized variants. Hyphenation with native MS provides unique capabilities for simultaneous heterogeneity assessment for mAbs, FcRn, and complexes formed. The latter provides information on binding stoichiometry revealing 1:1 and 1:2 for antibody/FcRn complexes. The use of differently engineered Fc-only constructs allowed distinguishing between symmetric and asymmetric binding. The approach opens up unique possibilities for proteoform-resolved antibody binding studies to FcRn and can be extended to other FcRs and protein interactions.
Collapse
|
12
|
Fast analysis of antibody-derived therapeutics by automated multidimensional liquid chromatography - Mass spectrometry. Anal Chim Acta 2021; 1184:339015. [PMID: 34625261 DOI: 10.1016/j.aca.2021.339015] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 08/23/2021] [Accepted: 08/30/2021] [Indexed: 12/01/2022]
Abstract
Characterization of post-translational modifications (PTMs) of therapeutic antibodies is commonly performed by bottom-up approaches, involving sample preparation and peptide analysis by liquid chromatography-mass spectrometry (LC-MS). Conventional sample preparation requires extensive hands-on time and can increase the risk of inducing artificial modifications as many off-line steps - denaturation, disulfide-reduction, alkylation and tryptic digestion - are performed. In this study, we developed an on-line multidimensional (mD)-LC-MS bottom-up approach for fast sample preparation and analysis of (formulated) monoclonal antibodies and antibody-derived therapeutics. This approach allows on-column reduction, tryptic digestion and subsequent peptide analysis by RP-MS. Optimization of the 1D -and 2D flow and temperature improved the trapping of small polar peptides during on-line peptide mapping analysis. These adaptations increased the sequence coverage (95-98% versus 86-94% for off-line approaches) and allowed identification of various PTMs (i.e. deamidation of asparagine, methionine oxidation and lysine glycation) within a single analysis. This workflow enables a fast (<2 h) characterization of antibody heterogeneities within a single run and a low amount of protein (10 μg). Importantly, the new mD-LC-MS bottom-up method was able to detect the polar, fast-eluting peptides: Fc oxidation at Hc-Met-252 and the Fc N-glycosylation at Hc-Asn-297, which can be challenging using mD-LC-MS. Moreover, the method showed good comparability across the different measurements (RSD of retention time in the range of 0.2-1.8% for polar peptides). The LC system was controlled by only a standard commercial software package which makes implementation for fast characterization of quality attributes relatively easy.
Collapse
|
13
|
Native Structural and Functional Proteoform Characterization of the Prolyl-Alanyl-Specific Endoprotease EndoPro from Aspergillus niger. J Proteome Res 2021; 20:4875-4885. [PMID: 34515489 PMCID: PMC8491274 DOI: 10.1021/acs.jproteome.1c00663] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
![]()
The prolyl-alanyl-specific
endoprotease (EndoPro) is an industrial
enzyme produced in Aspergillus niger. EndoPro is
mainly used for food applications but also as a protease in proteomics.
In-depth characterization of this enzyme is essential to understand
its structural features and functionality. However, there is a lack
of analytical methods capable of maintaining both the structural and
functional integrity of separated proteoforms. In this study, we developed
an anion exchange (AEX) method coupled to native mass spectrometry
(MS) for profiling EndoPro proteoforms. Moreover, we investigated
purified EndoPro proteoforms with complementary MS-based approaches,
including released N-glycan and glycopeptide analysis, to obtain a
comprehensive overview of the structural heterogeneity. We showed
that EndoPro has at least three sequence variants and seven N-glycosylation
sites occupied by high-mannose glycans that can be phosphorylated.
Each glycosylation site showed high microheterogeneity with ∼20
glycans per site. The functional characterization of fractionated
proteoforms revealed that EndoPro proteoforms remained active after
AEX-separation and the specificity of these proteoforms did not depend
on N-glycan phosphorylation. Nevertheless, our data confirmed a strong
pH dependence of EndoPro cleavage activity. Altogether, our study
demonstrates that AEX-MS is an excellent tool to characterize complex
industrial enzymes under native conditions.
Collapse
|
14
|
Abstract
As the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic is still ongoing and dramatically influences our life, the need for recombinant viral proteins for diagnostics, vaccine development, and research is very high. The spike (S) protein, and particularly its receptor-binding domain (RBD), mediates the interaction with the angiotensin-converting enzyme 2 (ACE2) receptor on host cells and may be modulated by its structural features. Therefore, well-characterized recombinant RBDs are essential. We have performed an in-depth structural and functional characterization of RBDs expressed in Chinese hamster ovary (CHO) and human embryonic kidney 293 (HEK293) cells. To structurally characterize the native RBDs (comprising N- and O-glycans and additional post translational modifications), a multilevel mass spectrometric approach was employed. Released glycan and glycopeptide analysis were integrated with intact mass analysis, glycan-enzymatic dissection, and top-down sequencing for comprehensive annotation of RBD proteoforms. The data showed distinct glycosylation for CHO- and HEK293-RBD with the latter exhibiting antenna fucosylation, a higher level of sialylation, and a combination of core 1 and core 2 type O-glycans. Additionally, using an alternative approach based on N-terminal cleavage of the O-glycosylation, the previously unknown O-glycosylation site was localized at T323. For both RBDs, the binding to SARS-CoV-2 antibodies of positive patients and affinity to the ACE2 receptor was addressed showing comparable results. This work not only offers insights into RBD structural and functional features but also provides an analytical workflow for characterization of new RBDs and batch-to-batch comparison.
Collapse
|
15
|
Profiling the proteoforms of urinary prostate-specific antigen by capillary electrophoresis - mass spectrometry. J Proteomics 2021; 238:104148. [PMID: 33618028 DOI: 10.1016/j.jprot.2021.104148] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Revised: 01/26/2021] [Accepted: 01/31/2021] [Indexed: 01/07/2023]
Abstract
Early detection of prostate cancer may lead to the overdiagnosis and overtreatment of patients as well as missing significant cancers. The current diagnostic approach uses elevated serum concentrations of prostate-specific antigen (PSA) as an indicator of risk. However, this test has been widely criticized as it shows poor specificity and sensitivity. In order to improve early detection and diagnosis, several studies have investigated whether different PSA proteoforms are correlated to prostate cancer. Until now, studies and methodologies for the comprehensive characterization of PSA proteoforms from biofluids are scarce. For this purpose, we developed an intact protein assay to analyze PSA by capillary electrophoresis-electrospray ionization-mass spectrometry after affinity purification from patients' urine. Here, we determined six proteolytic cleavage variants. In regard to glycosylation, tri-, di-, mono- and non-sialylated complex-type N-glycans were found on non-cleaved PSA, as well as the non-glycosylated variant. The performance of the intact protein assay was assessed using a pooled sample, obtaining an inter-day variability of 15%. Furthermore, urinary patient samples were analyzed by intact protein analysis and a bottom-up approach (glycopeptide analysis). This combined approach revealed complimentary information on both levels, demonstrating the benefit of using two orthogonal techniques to provide a thorough profile of urinary PSA. SIGNIFICANCE: The detection of clinically relevant prostate cancer requires a more specific and sensitive biomarker and, in this case, several PSA proteoforms may be able to aid or improve the current PSA test. However, a comprehensive analysis of the intact PSA proteoform profile is still lacking. This study investigated the PSA proteoforms present in urine and, in particular, determined the relative contribution of cleaved PSA and non-cleaved PSA forms to the total glycosylation profile. Importantly, intact protein analysis did not require further sample treatment before being measured by CE-ESI-MS. Furthermore, its glycosylation was also assessed in a bottom-up approach to provide complementary information. Overall, these results represent an important basis for future characterization and biomarker studies.
Collapse
|
16
|
Anion exchange chromatography – Mass spectrometry for monitoring multiple quality attributes of erythropoietin biopharmaceuticals. Anal Chim Acta 2021; 1143:166-172. [DOI: 10.1016/j.aca.2020.11.027] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 11/16/2020] [Accepted: 11/18/2020] [Indexed: 10/22/2022]
|
17
|
Intact and subunit-specific analysis of bispecific antibodies by sheathless CE-MS. Anal Chim Acta 2020; 1134:18-27. [DOI: 10.1016/j.aca.2020.07.069] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Revised: 07/18/2020] [Accepted: 07/27/2020] [Indexed: 01/15/2023]
|
18
|
Sheathless CE-MS as a tool for monitoring exchange efficiency and stability of bispecific antibodies. Electrophoresis 2020; 42:171-176. [PMID: 32901958 DOI: 10.1002/elps.202000166] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 07/23/2020] [Accepted: 08/14/2020] [Indexed: 01/17/2023]
Abstract
Bispecific monoclonal antibodies (BsAbs) are receiving great attention due to their extensive benefits as biopharmaceuticals and their involvement in IgG4 mediated autoimmune diseases. While the production of BsAbs is getting more accessible, their analytical characterization remains challenging. We explored the potential of sheathless CE-MS for monitoring exchange efficiency and stability of in-house produced bispecific antibodies. Two IgG4 bispecific antibodies with different molecular characteristics were prepared using controlled Fragment antigen binding (Fab)-arm exchange. Separation of BsAbs from their parent monospecific antibodies was achieved using a polyethyleniimine (PEI)-coated capillary and acidic background electrolytes permitting reliable assessment of the exchange efficiency. This was especially valuable for a Fab-glycosylated BsAb where the high glycan heterogeneity resulted in an overlap of masses with the monospecific parent antibody, hindering their discrimination by MS only. The method showed also good capabilities to monitor the stability of the generated BsAbs under different storage conditions. The levels of degradation products were different for the studied antibodies indicating pronounced differences in stability. Overall, the proposed method represents a useful analytical tool for exchange efficiency and stability studies of bispecific antibodies.
Collapse
|
19
|
MS-Based Allotype-Specific Analysis of Polyclonal IgG-Fc N-Glycosylation. Front Immunol 2020; 11:2049. [PMID: 32973813 PMCID: PMC7472933 DOI: 10.3389/fimmu.2020.02049] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Accepted: 07/28/2020] [Indexed: 12/18/2022] Open
Abstract
Current approaches to study glycosylation of polyclonal human immunoglobulins G (IgG) usually imply protein digestion or glycan release. While these approaches allow in-depth characterization, they also result in a loss of valuable information regarding certain subclasses, allotypes and co-occuring post-translational modifications (PTMs). Unfortunately, the high variability of polyclonal IgGs makes their intact mass spectrometry (MS) analysis extremely challenging. We propose here a middle-up strategy for the analysis of the intact fragment crystallizable (Fc) region of human plasma IgGs, with the aim of acquiring integrated information of the N-glycosylation and other PTMs of subclasses and allotypes. Human plasma IgG was isolated using Fc-specific beads followed by an on-bead C H 2 domain digestion with the enzyme IdeS. The obtained mixture of Fc subunits was analyzed by capillary electrophoresis (CE) and hydrophilic interaction liquid chromatography (HILIC) hyphenated with MS. CE-MS provided separation of different IgG-subclasses and allotypes, while HILIC-MS allowed resolution of the different glycoforms and their oxidized variants. The orthogonality of these techniques was key to reliably assign Fc allotypes. Five individual donors were analyzed using this approach. Heterozygosis was observed in all the analyzed donors resulting in a total of 12 allotypes identified. The assignments were further confirmed using recombinant monoclonal IgG allotypes as standards. While the glycosylation patterns were similar within allotypes of the same subclass, clear differences were observed between IgG subclasses and donors, highlighting the relevance of the proposed approach. In a single analysis, glycosylation levels specific for each allotype, relative abundances of subclasses and information on co-occurring modifications are obtained. This middle-up method represents an important step toward a comprehensive analysis of immunoglobulin G-Fc variants.
Collapse
|
20
|
Abstract
Determination of the impact of individual antibody glycoforms on FcɣRIIIa affinity, and consequently antibody-dependent cell-mediated cytotoxicity (ADCC) previously required high purity glycoengineering. We hyphenated FcɣRIIIa affinity chromatography to mass spectrometry, which allowed direct affinity comparison of glycoforms of intact monoclonal antibodies. The approach enabled reproduction and refinement of known glycosylation effects, and insights on afucosylation pairing as well as on low-abundant, unstudied glycoforms. Our method greatly improves the understanding of individual glycoform structure-function relationships. Thus, it is highly relevant for assessing Fc-glycosylation critical quality attributes related to ADCC.
Collapse
|
21
|
Chiral Discrimination of DL-Amino Acids by Trapped Ion Mobility Spectrometry after Derivatization with (+)-1-(9-Fluorenyl)ethyl Chloroformate. Anal Chem 2019; 91:3277-3285. [PMID: 30682252 PMCID: PMC6404107 DOI: 10.1021/acs.analchem.8b03661] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
![]()
A novel analytical
method based on hybrid trapped ion mobility
spectrometry-time-of-flight mass spectrometry (TIMS-TOFMS) has been
developed to achieve fast enantiomeric separation of amino acids (AAs).
Resolution of chiral AAs was achieved by forming diastereomers through
derivatization with the chiral agent (+)-1-(9-fluorenyl)ethyl chloroformate
(FLEC), avoiding the use of reference compounds. Electrospray ionization
(ESI) in positive mode yielded sodiated FLEC-AAs ions of which the
diastereomers could be separated by TIMS. The effect of other alkali
metal ions (such as Li and K) on the enantioselectivity was studied,
but chiral discrimination was only observed for Na. TIMS conditions,
including voltage ramp, ramp time, and accumulation time were optimized
for each AA, and collision cross sections (CCSs) were determined for
all diastereomers. The migration order of the DL enantiomers was found
to be dependent on the structure of the AA. The resulting TIMS resolution
(K0/ΔK0) for the FLEC-AA diastereomers on average was 115, requiring
a mobility (K0) difference of about 0.009 cm2/(V s) to
achieve 50%-valley separation. From the 21 AAs studied, enantiomer
separation was achieved for 17 AAs with mobility differences ranging
from 0.009 for lysine up to 0.061 cm2/(V s) for asparagine.
Moreover, the presented methodology provided mutual separation of
various AAs, allowing chiral analysis of multiple AAs simultaneously
which may be challenging with previous enantioselective IMS approaches.
It appeared possible to fully resolve all studied DL-AAs using three
distinct TIMS methods, resulting in a total MS run time of about 3
min (1 min per method) and a total analysis time (including derivatization)
of less than 15 min. The method demonstrated capable to determine
enantiomeric ratios down to 2.5% with detection limits for the D enantiomers
in the nanomolar range. This new TIMS-based methodology opens up possibilities
for easy and fast analysis of AA enantiomers.
Collapse
|
22
|
Heterogeneity assessment of antibody-derived therapeutics at the intact and middle-up level by low-flow sheathless capillary electrophoresis-mass spectrometry. Anal Chim Acta 2018; 1044:181-190. [DOI: 10.1016/j.aca.2018.08.024] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2018] [Revised: 08/09/2018] [Accepted: 08/12/2018] [Indexed: 01/18/2023]
|
23
|
Linking the concentrations of itraconazole and 2-hydroxypropyl-β-cyclodextrin in human intestinal fluids after oral intake of Sporanox®. Eur J Pharm Biopharm 2018; 132:231-236. [DOI: 10.1016/j.ejpb.2018.06.025] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2018] [Revised: 04/19/2018] [Accepted: 06/22/2018] [Indexed: 12/18/2022]
|
24
|
Abstract
![]()
Recent
progress in top-down proteomics has driven the demand for
chromatographic methods compatible with mass spectrometry (MS) that
can separate intact proteins. Hydrophilic interaction liquid chromatography
(HILIC) has recently shown good potential for the characterization
of glycoforms of intact proteins. In the present study, we demonstrate
that HILIC can separate a wide range of proteins exhibiting orthogonal
selectivity with respect to reversed-phase LC (RPLC). However, the
application of HILIC to the analysis of low abundance proteins (e.g.,
in proteomics analysis) is hampered by low volume loadability, hindering
down-scaling of the method to column diameters below 2.1 mm. Moreover,
HILIC-MS sensitivity is decreased due to ion suppression from the
trifluoroacetic acid (TFA) often used as the ion-pair agent to improve
the selectivity and efficiency in the analysis of glycoproteins. Here,
we introduce a capillary-based HILIC-MS method that overcomes these
problems. Our method uses RPLC trap-columns to load and inject the
sample, circumventing issues of protein solubility and volume loadability
in capillary columns (200 μm ID). The low flow rates and use
of a dopant gas in the electrospray interface improve protein-ionization
efficiencies and reduce suppression by TFA. Overall, this allows the
separation and detection of small protein quantities (down to 5 ng
injected on column) as indicated by the analysis of a mixture of model
proteins. The potential of the new capillary HILIC-MS is demonstrated
by the analysis of a complex cell lysate.
Collapse
|
25
|
High-resolution glycoform profiling of intact therapeutic proteins by hydrophilic interaction chromatography-mass spectrometry. Talanta 2018; 184:375-381. [PMID: 29674057 DOI: 10.1016/j.talanta.2018.03.015] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2018] [Revised: 03/05/2018] [Accepted: 03/07/2018] [Indexed: 11/18/2022]
Abstract
Glycosylation is considered a critical quality attribute of therapeutic proteins. Protein heterogeneity introduced by glycosylation includes differences in the nature, number and position of the glycans. Whereas analysis of released glycans and glycopeptides provides information about the composition and/or position of the glycan, intact glycoprotein analysis allows assignment of individual proteoforms and co-occurring modifications. Yet, resolving protein glycoforms at the intact level is challenging. We have explored the capacity of hydrophilic liquid chromatography-mass spectrometry (HILIC-MS) for assessing glycosylation patterns of intact pharmaceutical proteins by analyzing the complex glycoproteins interferon-beta-1a (rhIFN-β - 1a) and recombinant human erythropoietin (rhEPO). Efficient glycoform separation was achieved using a superficially-porous amide HILIC stationary phase and trifluoroacetic acid (TFA) as eluent additive. In-source collision-induced dissociation proved to be very useful to minimize protein-signal suppression effects by TFA. Direct injection of therapeutic proteins in aqueous formulation was possible without causing extra band dispersion, provided that the sample injection volume was not larger than 2 μL. HILIC-MS of rhIFN-β - 1a and rhEPO allowed the assignment of, respectively, 15 and 51 glycoform compositions, next to a variety of posttranslational modifications, such as succinimide, oxidation and N-terminal methionine-loss products. MS-based assignments showed that neutral glycan units significantly contributed to glycoform separation, whereas terminal sialic acids only had a marginal effect on HILIC retention. Comparisons of HILIC-MS with the selectivity provided by capillary electrophoresis-MS for the same glycoproteins, revealed a remarkable complementarity of the techniques. Finally it was demonstrated that by replacing TFA for difluoroacetic acid, peak resolution somewhat decreased, but rhEPO glycoforms with relative abundances below 1% could be detected by HILIC-MS, increasing the overall rhEPO glycoform coverage to 72.
Collapse
|
26
|
Hydrophilic interaction liquid chromatography-mass spectrometry as a new tool for the characterization of intact semi-synthetic glycoproteins. Anal Chim Acta 2017; 981:94-105. [PMID: 28693734 DOI: 10.1016/j.aca.2017.05.020] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2017] [Revised: 05/08/2017] [Accepted: 05/14/2017] [Indexed: 12/25/2022]
Abstract
Improved methods for detailed characterization of complex glycoproteins are required in the growing sector of biopharmaceuticals. Hydrophilic interaction liquid chromatography (HILIC) coupled to high resolution (HR) time-of-flight mass spectrometric (TOF-MS) detection was examined for the characterization of intact neo-glycoproteins prepared by chemical conjugation of synthetic saccharides to the lysine residues of selected recombinant proteins. The separation performances of three different amide HILIC columns (TSKgel Amide-80, XBridge BEH and AdvanceBio Glycan Mapping) were tested. Water-acetonitrile gradients and volatile eluent additives have been explored. Addition of 0.05% (v/v) trifluoroacetic acid to the mobile phase appeared to be essential for achieving optimum resolution of intact glycoforms and minimal ion suppression effects. Gradient elution conditions were optimized for each protein on every column. HILIC stationary phases were evaluated for the analysis of highly heterogeneous semi-synthetic derivatives of the same protein (ribonuclease A), and in the enhanced characterization of TB10.4 and Ag85B glycoconjugates, selected antigens from Mycobacterium tuberculosis (MTB). HILIC-MS results indicated that the HILIC selectivity is predominantly governed by size of the conjugated glycans and number of glycans attached, providing efficient glycoform separation. Moreover, HILIC separation prior to HRMS detection allowed assignment of several product impurities. Additional top-down MS/MS experiments confirmed conjugation at the N-terminus of TB10.4 next to its lysine residue. Overall, the obtained results demonstrate that amide-stationary-phase based HILIC coupled to MS is highly useful for the characterization of intact neo-glycoproteins allowing assessment of the number, identity and relative abundance of glycoforms present in the semi-synthetic products.
Collapse
|
27
|
Evaluation of capillary electrophoresis-mass spectrometry for the analysis of the conformational heterogeneity of intact proteins using beta 2-microglobulin as model compound. Anal Chim Acta 2016; 945:102-109. [PMID: 27968711 DOI: 10.1016/j.aca.2016.10.010] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2016] [Revised: 10/07/2016] [Accepted: 10/09/2016] [Indexed: 10/20/2022]
Abstract
In this work we explored the feasibility of different CE-ESI-MS set-ups for the analysis of conformational states of an intact protein. By using the same background electrolyte at quasi physiological conditions (50 mM ammonium bicarbonate, pH 7.4) a sequential optimization was carried out, initially by evaluating a sheath-liquid interface with both a single quadrupole (SQ) and a time-of-flight (TOF) mass spectrometer; then a sheathless interface coupled with high-resolution QTOF MS was considered. Beta2-microglobulin has been taken as a model, as it is an amyloidogenic protein and its conformational changes are strictly connected to the onset of a disease. The separation of two conformers at dynamic equilibrium is achieved all the way down to the MS detection. Notably, the equilibrium ratio of the protein conformers is maintained in the electrospray source after CE separation. Strengths and weaknesses of each optimized set-up are emphasized and their feasibility in unfolding studies is evaluated. In particular, ESI-TOF MS can assign protein forms that differ by 1 Da only and sheathless interfacing is best suited to preserve protein structure integrity. This demonstrates the CE-ESI-MS performance in terms of separation, detection and characterization of conformational species that co-populate a protein solution.
Collapse
|
28
|
Monitoring antigenic protein integrity during glycoconjugate vaccine synthesis using capillary electrophoresis-mass spectrometry. Anal Bioanal Chem 2016; 408:6123-32. [PMID: 27372716 PMCID: PMC4981626 DOI: 10.1007/s00216-016-9723-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2016] [Revised: 06/11/2016] [Accepted: 06/14/2016] [Indexed: 11/23/2022]
Abstract
A capillary electrophoresis-mass spectrometry (CE-MS) method was developed for the characterization and integrity assessment of the Mycobacterium tuberculosis (MTB) antigens TB10.4 and Ag85B and their chemically produced glycoconjugates, which are glycovaccine candidates against tuberculosis (TB). In order to prevent protein adsorption to the inner capillary wall and to achieve efficient separation of the antigen proteoforms, a polyionic multilayer coating of polybrene-dextran sulfate-polybrene (PB-DS-PB) was used in combination with 1.5 M acetic acid as background electrolyte (BGE). Coupling of CE to high-resolution time-of-flight MS was achieved by a coaxial interface employing a sheath liquid of isopropanol-water (50:50, v/v) containing 0.1 % formic acid. The MTB antigens were exposed to experimental conditions used for chemical glycosylation (but no activated saccharide was added) in order to investigate their stability during glycovaccine production. CE-MS analysis revealed the presence of several closely related degradation products, including truncated, oxidized and conformational variants, which were assigned by accurate mass. Analysis of synthesized mannose conjugates of TB10.4 and Ag85B allowed the determination of the glycoform composition of the neo-glycoproteins next to the characterization of degradation products which were shown to be partly glycoconjugated. Moreover, the selectivity of CE-MS allowed specific detection of deamidated species (protein mass change of 1.0 Da only), indicating that chemical glycosylation increased susceptibility to deamidation. Overall, the results show that CE-MS represents a useful analytical tool for the detailed characterization and optimization of neo-glycoconjugate products. Graphical Abstract Flowchart illustrating Mycobacterium tuberculosis (MTB) antigen glycosylation, glycoconjugate variant and degradation product separation by capillary electrophoresis (CE) and their characterization by intact mass spectrometry (MS).
Collapse
|
29
|
Abstract
Capillary electrophoresis (CE) coupled with mass spectrometry (MS) has proven to be a powerful analytical tool for the characterization of intact proteins. It combines the high separation efficiency, short analysis time, and versatility of CE with the mass selectivity and sensitivity offered by MS detection. This chapter focuses on important practical considerations when applying CE-MS for the analysis of intact proteins. Technological aspects with respect to the use of CE-MS interfaces and application of noncovalent capillary coatings preventing protein adsorption are treated. Critical factors for successful protein analysis are discussed and four typical CE-MS systems are described demonstrating the characterization of different types of intact proteins by CE-MS. These methodologies comprise the use of sheath-liquid and sheathless CE-MS interfaces, and various types of noncovalent capillary coatings allowing efficient and reproducible protein separations. The discussion includes the analysis of lysozyme-drug conjugates and the therapeutic proteins human growth hormone, human interferon-β-1a, and human erythropoietin.
Collapse
|
30
|
Analysis of antibiotics by CE and their use as chiral selectors: An update. Electrophoresis 2015; 37:189-211. [PMID: 26471773 DOI: 10.1002/elps.201500359] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2015] [Revised: 09/28/2015] [Accepted: 09/28/2015] [Indexed: 12/22/2022]
Abstract
The widespread use of antibiotics in medicine and as growth-promoting agents has increased the demand for suitable analytical techniques for their analysis. Analytical methods based on CE or miniaturized CE systems have proved over the years their ability for the analysis of antibiotics. Since our last review (Electrophoresis 2014, 35, 28-49) several new CE methodologies have been reported for antibiotic analysis. This review presents an update of the literature published from June 2013 to June 2015 for the analysis of antibiotics by CE. UV continues being the most used detection system for antibiotics analysis by CE. Strategies to improve sensitivity as the use of sensitive detection systems and the application of preconcentration techniques appear to be the major developments. Furthermore, the use of portable and miniaturized devices for antibiotic analysis is presented in detail. Applications of the developed methodologies to the determination of residues of antibiotics in biological, food, and environmental samples are carefully described. Finally, new developments and applications of antibiotics as chiral selectors in CE are also included.
Collapse
|
31
|
Simultaneous Assessment of Protein Heterogeneity and Affinity by Capillary Electrophoresis–Mass Spectrometry. Anal Chem 2015. [DOI: 10.1021/acs.analchem.5b01701] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
32
|
Recent advances in CE analysis of antibiotics and its use as chiral selectors. Electrophoresis 2014; 35:28-49. [PMID: 24395661 DOI: 10.1002/elps.201300347] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2013] [Revised: 10/06/2013] [Accepted: 10/06/2013] [Indexed: 12/24/2022]
Abstract
Antibiotics are a class of therapeutic molecules widely employed in both human and veterinary medicine. This article reviews the most recent advances in the analysis of antibiotics by CE in pharmaceutical, environmental, food, and biomedical fields. Emphasis is placed on the strategies to increase sensitivity as diverse off-line, in-line, and on-line preconcentration approaches and the use of different detection systems. The use of CE in the microchip format for the analysis of antibiotics is also reviewed in this article. Moreover, since the use of antibiotics as chiral selectors in CE has grown in the last years, a new section devoted to this aspect has been included. This review constitutes an update of previous published reviews and covers the literature published from June 2011 until June 2013.
Collapse
|
33
|
Potential of vancomycin for the enantiomeric resolution of FMOC-amino acids by capillary electrophoresis-ion-trap-mass spectrometry. Electrophoresis 2014; 35:1244-50. [PMID: 24338646 DOI: 10.1002/elps.201300489] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2013] [Revised: 11/29/2013] [Accepted: 11/29/2013] [Indexed: 11/07/2022]
Abstract
The potential of the antibiotic vancomycin (VC) as chiral selector for the enantiomeric separation of amino acids by CE-ESI-MS/MS² was investigated for the first time in this work. Derivatization of amino acids with FMOC-Cl was carried out to enable their interaction with VC as well as the formation of precursor ions with larger m/z which were employed in MS² experiments. The partial filling of a coated capillary was employed to avoid the loss in MS sensitivity originated by the introduction of VC in the ionization source. Under optimized conditions, the simultaneous enantiomeric separation and unequivocal identification of 17 amino acids (two of them being nonprotein amino acids) took place in about 20 min with LODs in the micromolar range.
Collapse
|
34
|
Low-picomolar analysis of peptides by on-line coupling of fritless solid-phase extraction to sheathless capillary electrophoresis-mass spectrometry. J Chromatogr A 2013; 1328:1-6. [PMID: 24438833 DOI: 10.1016/j.chroma.2013.12.080] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2013] [Revised: 12/09/2013] [Accepted: 12/24/2013] [Indexed: 01/01/2023]
Abstract
A novel fritless solid-phase extraction (SPE) microcartridge was designed for combination with sheathless capillary electrophoresis-mass spectrometry (sheathless CE-MS) employing a prototype porous-tip capillary for nanoelectrospray ionization (nanoESI). The inlet of the separation capillary (30μm inner diameter (id), 150μm outer diameter (od)) was inserted in a 4mm long SPE microcartridge (150μm id, 365μm od) packed with a C18 sorbent of 55-105μm particle size. Performance of the SPE-CE-MS system was evaluated using diluted solutions of the three opioid peptides dynorphin A (1-7) (DynA), endomorphin 1 (End1) and met-enkephalin (Met). Sample volumes of 1.5μL were loaded on the SPE microcartridge and the retained peptides were eluted with 22nL of an acidic methanol/water (60:40, v/v) solution. Using a pressure of 50mbar during separation to speed up the analysis, good peptide resolution was obtained with acceptable plate numbers (between 53,000 and 92,000). Intraday relative standard deviations (% RSD) for peptide migration times and peak areas were below 4% and 9%, respectively. The SPE-CE-MS method showed good linearity in the 0.05-5ngmL(-1) range and limits of detection (LODs) were 10pgmL(-1). However, loading a larger volume of sample (8μL), LODs could be decreased down to 2pgmL(-1) (2.2-3.5pM). This represents an improvement of up to 5000-fold with respect to the LODs achieved by sheathless CE-MS without on-line preconcentration demonstrating the potential of on-line SPE for further enhancing sensitivity.
Collapse
|
35
|
Abstract
Capillary electrophoresis-mass spectrometry (CE-MS) is a powerful analytical tool, especially in the case of chiral separations, due to the fact that it combines the high efficiency, short analysis time, and versatility of the CE with the sensitivity, selectivity, and the capacity for the identification of unknown chiral compounds offered by MS detection. This chapter describes three methodologies enabling the chiral separation of cationic and anionic compounds using different strategies, illustrating the most employed approaches used in chiral CE-MS. The first methodology uses the partial filling technique for the enantioseparation of a cationic compound using a neutral cyclodextrin. Secondly, the enantioseparation of a cationic compound using low concentrations of a neutral cyclodextrin under acidic conditions is described. Finally, a methodology for the chiral separation of an anionic compound employing low concentrations of a native cyclodextrin under basic conditions is illustrated.
Collapse
|
36
|
Recent advances in the analysis of antibiotics by CE and CEC. Electrophoresis 2011; 33:127-46. [DOI: 10.1002/elps.201100409] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2011] [Revised: 09/17/2011] [Accepted: 09/19/2011] [Indexed: 11/09/2022]
|
37
|
Enantiomeric separation of FMOC-amino acids by nano-LC and CEC using a new chiral stationary phase, cellulose tris(3-chloro-4-methylphenylcarbamate). Electrophoresis 2011; 32:2700-7. [DOI: 10.1002/elps.201000701] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2010] [Revised: 02/16/2011] [Accepted: 02/16/2011] [Indexed: 11/05/2022]
|
38
|
Fast determination of the functional peptide soymetide in different soybean derived foods by capillary-high performance liquid chromatography. J Chromatogr A 2011; 1218:4928-33. [DOI: 10.1016/j.chroma.2011.05.055] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2010] [Revised: 05/12/2011] [Accepted: 05/14/2011] [Indexed: 10/18/2022]
|
39
|
First approach based on direct ultrasonic assisted enzymatic digestion and capillary-high performance liquid chromatography for the peptide mapping of soybean proteins. J Chromatogr A 2010; 1217:6443-8. [DOI: 10.1016/j.chroma.2010.08.027] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2010] [Revised: 07/30/2010] [Accepted: 08/09/2010] [Indexed: 11/25/2022]
|
40
|
CE-TOF MS analysis of complex protein hydrolyzates from genetically modified soybeans--a tool for foodomics. Electrophoresis 2010; 31:1175-1183. [PMID: 20209569 DOI: 10.1002/elps.200900448] [Citation(s) in RCA: 85] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2023]
Abstract
A CE-TOF MS proteomic approach was applied for the analysis of hydrolyzates from complex soybean protein mixtures. After CE-TOF MS method development, the new approach provided the simultaneous analysis of more than 150 peptides from the soybean protein fraction soluble in ACN-water (80/20 v/v). The method is fast (about 30 min of analysis per sample) and is characterized by a relatively low running cost. The approach was used to study the substantial equivalence between a genetically modified variety of soybean compared with its traditional counterpart. No significant differences were found between the two studied soybeans based on the protein fraction studied. The capacity of the CE-TOF MS method to analyze complex mixtures of peptides in short times opens interesting possibilities in the growing Foodomics area.
Collapse
|
41
|
Development of a CE-ESI-ITMS method for the enantiomeric determination of the non-protein amino acid ornithine. Electrophoresis 2009; 30:1724-33. [DOI: 10.1002/elps.200800679] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
42
|
Fast derivatization of the non-protein amino acid ornithine with FITC using an ultrasound probe prior to enantiomeric determination in food supplements by EKC. Electrophoresis 2009; 30:1037-45. [DOI: 10.1002/elps.200800358] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|