1
|
Clifton LA, Skoda MWA, Daulton EL, Hughes AV, Le Brun AP, Lakey JH, Holt SA. Asymmetric phospholipid: lipopolysaccharide bilayers; a Gram-negative bacterial outer membrane mimic. J R Soc Interface 2013; 10:20130810. [PMID: 24132206 PMCID: PMC3808558 DOI: 10.1098/rsif.2013.0810] [Citation(s) in RCA: 92] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2013] [Accepted: 09/25/2013] [Indexed: 01/02/2023] Open
Abstract
The Gram-negative bacterial outer membrane (OM) is a complex and highly asymmetric biological barrier but the small size of bacteria has hindered advances in in vivo examination of membrane dynamics. Thus, model OMs, amenable to physical study, are important sources of data. Here, we present data from asymmetric bilayers which emulate the OM and are formed by a simple two-step approach. The bilayers were deposited on an SiO2 surface by Langmuir-Blodgett deposition of phosphatidylcholine as the inner leaflet and, via Langmuir-Schaefer deposition, an outer leaflet of either Lipid A or Escherichia coli rough lipopolysaccharides (LPS). The membranes were examined using neutron reflectometry (NR) to examine the coverage and mixing of lipids between the bilayer leaflets. NR data showed that in all cases, the initial deposition asymmetry was mostly maintained for more than 16 h. This stability enabled the sizes of the headgroups and bilayer roughness of 1,2-dipalmitoyl-sn-glycero-3-phosphocholine and Lipid A, Rc-LPS and Ra-LPS to be clearly resolved. The results show that rough LPS can be manipulated like phospholipids and used to fabricate advanced asymmetric bacterial membrane models using well-known bilayer deposition techniques. Such models will enable OM dynamics and interactions to be studied under in vivo-like conditions.
Collapse
|
research-article |
12 |
92 |
2
|
Clifton LA, Holt SA, Hughes AV, Daulton EL, Arunmanee W, Heinrich F, Khalid S, Jefferies D, Charlton TR, Webster JRP, Kinane CJ, Lakey JH. An accurate in vitro model of the E. coli envelope. Angew Chem Int Ed Engl 2015; 54:11952-5. [PMID: 26331292 PMCID: PMC4600229 DOI: 10.1002/anie.201504287] [Citation(s) in RCA: 81] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2015] [Revised: 08/07/2015] [Indexed: 11/05/2022]
Abstract
Gram-negative bacteria are an increasingly serious source of antibiotic-resistant infections, partly owing to their characteristic protective envelope. This complex, 20 nm thick barrier includes a highly impermeable, asymmetric bilayer outer membrane (OM), which plays a pivotal role in resisting antibacterial chemotherapy. Nevertheless, the OM molecular structure and its dynamics are poorly understood because the structure is difficult to recreate or study in vitro. The successful formation and characterization of a fully asymmetric model envelope using Langmuir-Blodgett and Langmuir-Schaefer methods is now reported. Neutron reflectivity and isotopic labeling confirmed the expected structure and asymmetry and showed that experiments with antibacterial proteins reproduced published in vivo behavior. By closely recreating natural OM behavior, this model provides a much needed robust system for antibiotic development.
Collapse
|
Research Support, Non-U.S. Gov't |
10 |
81 |
3
|
Widlak MM, Neal M, Daulton E, Thomas CL, Tomkins C, Singh B, Harmston C, Wicaksono A, Evans C, Smith S, Savage RS, Covington JA, Arasaradnam RP. Risk stratification of symptomatic patients suspected of colorectal cancer using faecal and urinary markers. Colorectal Dis 2018; 20:O335-O342. [PMID: 30248228 DOI: 10.1111/codi.14431] [Citation(s) in RCA: 55] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2018] [Accepted: 09/17/2018] [Indexed: 12/15/2022]
Abstract
AIM Faecal markers, such as the faecal immunochemical test for haemoglobin (FIT) and faecal calprotectin (FCP), have been increasingly used to exclude colorectal cancer (CRC) and colonic inflammation. However, in those with lower gastrointestinal symptoms there are considerable numbers who have cancer but have a negative FIT test (i.e. false negative), which has impeded its use in clinical practice. We undertook a study of diagnostic accuracy CRC using FIT, FCP and urinary volatile organic compounds (VOCs) in patients with lower gastrointestinal symptoms. METHOD One thousand and sixteen symptomatic patients with suspected CRC referred by family physicians were recruited prospectively in accordance with national referring protocol. A total of 562 patients who completed colonic investigations, in addition to providing stool for FIT and FCP as well as urine samples for urinary VOC measurements, were included in the final outcome measures. RESULTS The sensitivity and specificity for CRC using FIT was 0.80 [95% confidence interval (CI) 0.66-0.93] and 0.93 (CI 0.91-0.95), respectively. For urinary VOCs, the sensitivity and specificity for CRC was 0.63 (CI 0.46-0.79) and 0.63 (CI 0.59-0.67), respectively. However, for those who were FIT-negative CRC (i.e. false negatives), the addition of urinary VOCs resulted in a sensitivity of 0.97 (CI 0.90-1.0) and specificity of 0.72 (CI 0.68-0.76). CONCLUSIONS When applied to the FIT-negative group, urinary VOCs improve CRC detection (sensitivity rises from 0.80 to 0.97), thus showing promise as a second-stage test to complement FIT in the detection of CRC.
Collapse
|
Clinical Trial |
7 |
55 |
4
|
Daulton E, Wicaksono AN, Tiele A, Kocher HM, Debernardi S, Crnogorac-Jurcevic T, Covington JA. Volatile organic compounds (VOCs) for the non-invasive detection of pancreatic cancer from urine. Talanta 2020; 221:121604. [PMID: 33076134 DOI: 10.1016/j.talanta.2020.121604] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 08/25/2020] [Accepted: 08/27/2020] [Indexed: 02/07/2023]
Abstract
Pancreatic ductal adenocarcinoma (PDAC) is a particularly challenging cancer, with very low 5-year survival rates. This low survival rate is linked to late stage diagnosis, associated with the lack of approved biomarkers. One approach that is receiving considerable attention is the use of volatile organic compounds (VOCs) that emanate from biological waste as biomarkers for disease. In this study, we used urine as our biological matrix and two VOC analysis platforms: gas chromatography - ion mobility spectrometry (GC-IMS) and GC time-of-flight mass spectrometry (GC-TOF-MS). We measured the urinary headspace of samples from patients with PDAC, chronic pancreatitis (CP) and healthy controls. In total, 123 samples were tested from these groups. Results indicate that both GC-IMS and GC-TOF-MS were able to discriminate PDAC from healthy controls with high confidence and an AUC (area under the curve) in excess of 0.85. However, both methods struggled to separate CP from PDAC, with the best result of AUC 0.58. This indicates that both conditions produce similar biomarkers in the urinary headspace. Chemical identification suggests that 2,6-dimethyl-octane, nonanal, 4-ethyl-1,2-dimethyl-benzene and 2-pentanone play an important role in separating these groups. Therefore, both techniques validate this approach in identifying subjects for further investigation in a clinical setting.
Collapse
|
Journal Article |
5 |
51 |
5
|
Bannaga AS, Tyagi H, Daulton E, Covington JA, Arasaradnam RP. Exploratory Study Using Urinary Volatile Organic Compounds for the Detection of Hepatocellular Carcinoma. Molecules 2021; 26:2447. [PMID: 33922256 PMCID: PMC8122735 DOI: 10.3390/molecules26092447] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 04/17/2021] [Accepted: 04/20/2021] [Indexed: 02/07/2023] Open
Abstract
Hepatocellular carcinoma (HCC) biomarkers are lacking in clinical practice. We therefore explored the pattern and composition of urinary volatile organic compounds (VOCs) in HCC patients. This was done in order to assess the feasibility of a potential non-invasive test for HCC, and to enhance our understanding of the disease. This pilot study recruited 58 participants, of whom 20 were HCC cases and 38 were non-HCC cases. The non-HCC cases included healthy individuals and patients with various stages of non-alcoholic fatty liver disease (NAFLD), including those with and without fibrosis. Urine was analysed using gas chromatography-ion mobility spectrometry (GC-IMS) and gas chromatography-time-of-flight mass spectrometry (GC-TOF-MS). GC-IMS was able to separate HCC from fibrotic cases with an area under the curve (AUC) of 0.97 (0.91-1.00), and from non-fibrotic cases with an AUC of 0.62 (0.48-0.76). For GC-TOF-MS, a subset of samples was analysed in which seven chemicals were identified and tentatively linked with HCC. These include 4-methyl-2,4-bis(p-hydroxyphenyl)pent-1-ene (2TMS derivative), 2-butanone, 2-hexanone, benzene, 1-ethyl-2-methyl-, 3-butene-1,2-diol, 1-(2-furanyl)-, bicyclo(4.1.0)heptane, 3,7,7-trimethyl-, [1S-(1a,3β,6a)]-, and sulpiride. Urinary VOC analysis using both GC-IMS and GC-TOF-MS proved to be a feasible method of identifying HCC cases, and was also able to enhance our understanding of HCC pathogenesis.
Collapse
|
research-article |
4 |
26 |
6
|
Tyagi H, Daulton E, Bannaga AS, Arasaradnam RP, Covington JA. Non-Invasive Detection and Staging of Colorectal Cancer Using a Portable Electronic Nose. SENSORS (BASEL, SWITZERLAND) 2021; 21:5440. [PMID: 34450881 PMCID: PMC8398649 DOI: 10.3390/s21165440] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 07/30/2021] [Accepted: 07/30/2021] [Indexed: 12/24/2022]
Abstract
Electronic noses (e-nose) offer potential for the detection of cancer in its early stages. The ability to analyse samples in real time, at a low cost, applying easy-to-use and portable equipment, gives e-noses advantages over other technologies, such as Gas Chromatography-Mass Spectrometry (GC-MS). For diseases such as cancer with a high mortality, a technology that can provide fast results for use in routine clinical applications is important. Colorectal cancer (CRC) is among the highest occurring cancers and has high mortality rates, if diagnosed late. In our study, we investigated the use of portable electronic nose (PEN3), with further analysis using GC-TOF-MS, for the analysis of gases and volatile organic compounds (VOCs) to profile the urinary metabolome of colorectal cancer. We also compared the different cancer stages with non-cancers using the PEN3 and GC-TOF-MS. Results obtained from PEN3, and GC-TOF-MS demonstrated high accuracy for the separation of CRC and non-cancer. PEN3 separated CRC from non-cancerous group with 0.81 AUC (Area Under the Curve). We used data from GC-TOF-MS to obtain a VOC profile for CRC, which identified 23 potential biomarker VOCs for CRC. Thus, the PEN3 and GC-TOF-MS were found to successfully separate the cancer group from the non-cancer group.
Collapse
|
research-article |
4 |
26 |
7
|
Sahota AS, Gowda R, Arasaradnam RP, Daulton E, Savage RS, Skinner JR, Adams E, Ward SA, Covington JA. A simple breath test for tuberculosis using ion mobility: A pilot study. Tuberculosis (Edinb) 2016; 99:143-146. [PMID: 27450016 DOI: 10.1016/j.tube.2016.05.005] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2016] [Revised: 05/18/2016] [Accepted: 05/22/2016] [Indexed: 11/26/2022]
Abstract
Tuberculosis (TB) remains one of the world's major health burdens with 9.6 million new infections globally. Though considerable progress has been made in reduction of TB incidence and mortality, there is a continuous need for lower cost, simpler and more robust means of diagnosis. One method that may fulfil these requirements is in the area of breath analysis. In this study we analysed the breath of 21 patients with pulmonary or extra-pulmonary TB, recruited from a UK teaching hospital (University Hospital Coventry and Warwickshire) before or within 1 week of commencing treatment for TB. TB diagnosis was confirmed by reference tests (mycobacterial culture), histology or radiology. 19 controls were recruited to calculate specificity; these patients were all interferon-gamma release assay negative (T.SPOT(®).TB, Oxford Immunotec Ltd.). Whole breath samples were collected with subsequent chemical analysis undertaken by Ion Mobility Spectrometry. Our results produced a sensitivity of 81% and a specificity of 79% for all cases of TB (pulmonary and extra-pulmonary). Though lower than other studies analysing pulmonary TB alone, we believe that this technique shows promise, and a higher sensitivity could be achieved by further improving our sample capture methodology.
Collapse
|
Research Support, Non-U.S. Gov't |
9 |
25 |
8
|
Hughes AV, Holt SA, Daulton E, Soliakov A, Charlton TR, Roser SJ, Lakey JH. High coverage fluid-phase floating lipid bilayers supported by ω-thiolipid self-assembled monolayers. J R Soc Interface 2015; 11:20140245. [PMID: 25030385 PMCID: PMC4233693 DOI: 10.1098/rsif.2014.0447] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
Large area lipid bilayers, on solid surfaces, are useful in physical studies of biological membranes. It is advantageous to minimize the interactions of these bilayers with the substrate and this can be achieved via the formation of a floating supported bilayer (FSB) upon either a surface bound phospholipid bilayer or monolayer. The FSB's independence is enabled by the continuous water layer (greater than 15 Å) that remains between the two. However, previous FSBs have had limited stability and low density. Here, we demonstrate by surface plasmon resonance and neutron reflectivity, the formation of a complete self-assembled monolayer (SAM) on gold surfaces by a synthetic phosphatidylcholine bearing a thiol group at the end of one fatty acyl chain. Furthermore, a very dense FSB (more than 96%) of saturated phosphatidylcholine can be formed on this SAM by sequential Langmuir–Blodgett and Langmuir–Schaefer procedures. Neutron reflectivity used both isotopic and magnetic contrast to enhance the accuracy of the data fits. This system offers the means to study transmembrane proteins, membrane potential effects (using the gold as an electrode) and even model bacterial outer membranes. Using unsaturated phosphatidylcholines, which have previously failed to form stable FSBs, we achieved a coverage of 73%.
Collapse
|
Research Support, Non-U.S. Gov't |
10 |
22 |
9
|
Tiele A, Wicaksono A, Daulton E, Ifeachor E, Eyre V, Clarke S, Timings L, Pearson S, Covington JA, Li X. Breath-based non-invasive diagnosis of Alzheimer's disease: a pilot study. J Breath Res 2020; 14:026003. [PMID: 31816609 DOI: 10.1088/1752-7163/ab6016] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Early detection of Alzheimer's disease (AD) will help researchers to better understand the disease and develop improved treatments. Recent developments have thus focused on identifying biomarkers for mild cognitive impairment due to AD (MCI) and AD during the preclinical phase. The aim of this pilot study is to determine whether exhaled volatile organic compounds (VOCs) can be used as a non-invasive method to distinguish controls from MCI, controls from AD and to determine whether there are differences between MCI and AD. The study used gas chromatography-ion mobility spectrometry (GC-IMS) techniques. Confounding factors, such as age, smoking habits, gender and alcohol consumption are investigated to demonstrate the efficacy of results. One hundred subjects were recruited including 50 controls, 25 AD and 25 MCI patients. The subject cohort was age- and gender-matched to minimise bias. Breath samples were analysed using a commercial GC-IMS instrument (G.A.S. BreathSpec, Dortmund, Germany). Data analysis indicates that the GC-IMS signal was consistently able to separate between diagnostic groups [AUC ± 95%, sensitivity, specificity], controls versus MCI: [0.77 (0.64-0.90), 0.68, 0.80], controls versus AD: [0.83 (0.72-0.94), 0.60, 0.96], and MCI versus AD: [0.70 (0.55-0.85), 0.60, 0.84]. VOC analysis indicates that six compounds play a crucial role in distinguishing between diagnostic groups. Analysis of possible confounding factors indicate that gender, age, smoking habits and alcohol consumption have insignificant influence on breath content. This pilot study confirms the utility of exhaled breath analysis to distinguish between AD, MCI and control subjects. Thus, GC-IMS offers great potential as a non-invasive, high-throughput, diagnostic technique for diagnosing and potentially monitoring AD in a clinical setting.
Collapse
|
Research Support, Non-U.S. Gov't |
5 |
21 |
10
|
Tyagi H, Daulton E, Bannaga AS, Arasaradnam RP, Covington JA. Urinary Volatiles and Chemical Characterisation for the Non-Invasive Detection of Prostate and Bladder Cancers. BIOSENSORS 2021; 11:bios11110437. [PMID: 34821653 PMCID: PMC8615657 DOI: 10.3390/bios11110437] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 10/27/2021] [Accepted: 10/29/2021] [Indexed: 05/08/2023]
Abstract
Bladder cancer (BCa) and prostate cancer (PCa) are some of the most common cancers in the world. In both BCa and PCa, the diagnosis is often confirmed with an invasive technique that carries a risk to the patient. Consequently, a non-invasive diagnostic approach would be medically desirable and beneficial to the patient. The use of volatile organic compounds (VOCs) for disease diagnosis, including cancer, is a promising research area that could support the diagnosis process. In this study, we investigated the urinary VOC profiles in BCa, PCa patients and non-cancerous controls by using gas chromatography-ion mobility spectrometry (GC-IMS) and gas chromatography time-of-flight mass spectrometry (GC-TOF-MS) to analyse patient samples. GC-IMS separated BCa from PCa (area under the curve: AUC: 0.97 (0.93-1.00)), BCa vs. non-cancerous (AUC: 0.95 (0.90-0.99)) and PCa vs. non-cancerous (AUC: 0.89 (0.83-0.94)) whereas GC-TOF-MS differentiated BCa from PCa (AUC: 0.84 (0.73-0.93)), BCa vs. non-cancerous (AUC: 0.81 (0.70-0.90)) and PCa vs. non-cancerous (AUC: 0.94 (0.90-0.97)). According to our study, a total of 34 biomarkers were found using GC-TOF-MS data, of which 13 VOCs were associated with BCa, seven were associated with PCa, and 14 VOCs were found in the comparison of BCa and PCa.
Collapse
|
research-article |
4 |
20 |
11
|
Arasaradnam RP, McFarlane M, Daulton E, Westenbrink E, O’Connell N, Wurie S, Nwokolo CU, Bardhan KD, Savage RS, Covington JA. Non-Invasive Distinction of Non-Alcoholic Fatty Liver Disease using Urinary Volatile Organic Compound Analysis: Early Results. JOURNAL OF GASTROINTESTINAL AND LIVER DISEASES 2015; 24:197-201. [DOI: 10.15403/jgld.2014.1121.242.ury] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/30/2023]
Abstract
Background & Aims: Non-Alcoholic Fatty Liver Disease (NAFLD) is the commonest cause of chronic liver disease in the western world. Current diagnostic methods including Fibroscan have limitations, thus there is a need for more robust non-invasive screening methods. The gut microbiome is altered in several gastrointestinal and hepatic disorders resulting in altered, unique gut fermentation patterns, detectable by analysis of volatile organic compounds (VOCs) in urine, breath and faeces. We performed a proof of principle pilot study to determine if progressive fatty liver disease produced an altered urinary VOC pattern; specifically NAFLD and Non-Alcoholic Steatohepatitis (NASH).Methods: 34 patients were recruited: 8 NASH cirrhotics (NASH-C); 7 non-cirrhotic NASH; 4 NAFLD and 15 controls. Urine was collected and stored frozen. For assay, the samples were defrosted and aliquoted into vials, which were heated to 40±0.1°C and the headspace analyzed by FAIMS (Field Asymmetric Ion Mobility Spectroscopy). A previously used data processing pipeline employing a Random Forrest classification algorithm and using a 10 fold cross validation method was applied.Results: Urinary VOC results demonstrated sensitivity of 0.58 (0.33 - 0.88), but specificity of 0.93 (0.68 - 1.00) and an Area Under Curve (AUC) 0.73 (0.55 -0.90) to distinguish between liver disease and controls. However, NASH/NASH-C was separated from the NAFLD/controls with a sensitivity of 0.73 (0.45 - 0.92), specificity of 0.79 (0.54 - 0.94) and AUC of 0.79 (0.64 - 0.95), respectively.Conclusions: This pilot study suggests that urinary VOCs detection may offer the potential for early non-invasive characterisation of liver disease using 'smell prints' to distinguish between NASH and NAFLD.
Collapse
|
|
10 |
19 |
12
|
Bosch S, Bot R, Wicaksono A, Savelkoul E, van der Hulst R, Kuijvenhoven J, Stokkers P, Daulton E, Covington JA, de Meij TGJ, de Boer NKH. Early detection and follow-up of colorectal neoplasia based on faecal volatile organic compounds. Colorectal Dis 2020; 22:1119-1129. [PMID: 32040880 DOI: 10.1111/codi.15009] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2019] [Accepted: 02/03/2020] [Indexed: 12/22/2022]
Abstract
AIM Early detection and removal of colorectal cancer (CRC) and advanced adenomas (AAs) decreases the incidence of and mortality from the disease. We aimed to evaluate the potential of faecal volatile organic compounds (VOCs) for detection and follow-up of colorectal adenoma using advanced electronic nose technology. METHOD This was a prospective multi-centre case-control cohort including two district hospitals and one tertiary referral hospital. Patients undergoing colonoscopy were instructed to collect a faecal sample prior to bowel cleansing and were included in the study when CRC, AAs, large adenomas (LAs; 0.5-1.0 cm), small adenomas (SAs; 0.1-0.5 cm) or no endoscopic abnormalities (controls) were observed. Patients undergoing polypectomy and controls were asked for a second sample after 3 months. Faecal VOCs were measured with gas chromatography-ion mobility spectrometry. Random forest, support vector machine, Gaussian process and neural net classification were used to evaluate accuracy. RESULTS In total, 14 patients with CRC, 64 with AAs, 69 with LAs, 127 with SAs and 227 controls were included. A second sample was collected from 32 polypectomy patients and 32 controls. Faecal VOCs discriminated CRC and adenomas from control [AUC (95% CI): CRC vs control 0.96 (0.89-1); AA vs control 0.96 (0.93-1); LA vs control 0.96 (0.92-0.99); SA vs control 0.96 (0.94-0.99)]. There were no significant differences between CRC and adenoma groups. Patients with adenomas and controls were discriminated prior to polypectomy, whereas 3 months after polypectomy VOC profiles were similar [T0 adenoma vs control 0.98 (0.95-1); T1 adenoma vs control 0.55 (0.40-0.69)]. CONCLUSIONS Faecal VOC profiles may be useful for early detection of CRC and adenomas and the timing of polyp surveillance as polypectomy led to a normalization of the VOC profile.
Collapse
|
|
5 |
12 |
13
|
Daulton E, Wicaksono A, Bechar J, Covington JA, Hardwicke J. The Detection of Wound Infection by Ion Mobility Chemical Analysis. BIOSENSORS-BASEL 2020; 10:bios10030019. [PMID: 32121452 PMCID: PMC7146168 DOI: 10.3390/bios10030019] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/06/2020] [Revised: 02/24/2020] [Accepted: 02/26/2020] [Indexed: 12/31/2022]
Abstract
Surgical site infection represents a large burden of care in the National Health Service. Current methods for diagnosis include a subjective clinical assessment and wound swab culture that may take several days to return a result. Both techniques are potentially unreliable and result in delays in using targeted antibiotics. Volatile organic compounds (VOCs) are produced by micro-organisms such as those present in an infected wound. This study describes the use of a device to differentiate VOCs produced by an infected wound vs. colonised wound. Malodourous wound dressings were collected from patients, these were a mix of post-operative wounds and vascular leg ulcers. Wound microbiology swabs were taken and antibiotics commenced as clinically appropriate. A control group of soiled, but not malodorous wound dressings were collected from patients who had a split skin graft (SSG) donor site. The analyser used was a G.A.S. GC-IMS. The results from the samples had a sensitivity of 100% and a specificity of 88%, with a positive predictive value of 90%. An area under the curve (AUC) of 91% demonstrates an excellent ability to discriminate those with an infected wound from those without. VOC detection using GC-IMS has the potential to serve as a diagnostic tool for the differentiation of infected and non-infected wounds and facilitate the treatment of wound infections that is cost effective, non-invasive, acceptable to patients, portable, and reliable.
Collapse
|
Journal Article |
5 |
10 |
14
|
Lacey L, Daulton E, Wicaksono A, Covington JA, Quenby S. Volatile organic compound analysis, a new tool in the quest for preterm birth prediction-an observational cohort study. Sci Rep 2020; 10:12153. [PMID: 32699319 PMCID: PMC7376243 DOI: 10.1038/s41598-020-69142-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Accepted: 07/01/2020] [Indexed: 01/26/2023] Open
Abstract
Preterm birth is the leading cause of death worldwide in children under five years. Due to its complex multifactorial nature, prediction is a challenge. Current research is aiming to develop accurate predictive models using patient history, ultrasound and biochemical markers. Volatile organic compound (VOC) analysis is an approach, which has good diagnostic potential to predict many disease states. Analysis of VOCs can reflect both the microbiome and host response to a condition. We aimed to ascertain if VOC analysis of vaginal swabs, taken throughout pregnancy, could predict which women go on to deliver preterm. Our prospective observational cohort study demonstrates that VOC analysis of vaginal swabs, taken in the midtrimester, is a fair test (AUC 0.79) for preterm prediction, with a sensitivity of 0.66 (95%CI 0.56–0.75) and specificity 0.89 (95%CI 0.82–0.94). Using vaginal swabs taken closest to delivery, VOC analysis is a good test (AUC 0.84) for the prediction of preterm birth with a sensitivity of 0.73 (95%CI 0.64–0.81) and specificity of 0.90 (95%CI 0.82–0.95). Consequently, VOC analysis of vaginal swabs has potential to be used as a predictive tool. With further work it could be considered as an additional component in models for predicting preterm birth.
Collapse
|
Research Support, Non-U.S. Gov't |
5 |
8 |
15
|
McFarlanE M, MozdiaK E, Daulton E, Arasaradnam R, Covington J, Nwokolo C. Pre-analytical and analytical variables that influence urinary volatile organic compound measurements. PLoS One 2020; 15:e0236591. [PMID: 32735600 PMCID: PMC7394370 DOI: 10.1371/journal.pone.0236591] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Accepted: 07/08/2020] [Indexed: 01/25/2023] Open
Abstract
There has been rapidly accelerating interest in the utilization of volatile organic compounds (VOCs) as non-invasive methods for rapid point-of-care medical diagnostics. There is widespread variation in analytical methods and protocols, with little understanding of the effects of sample storage on VOC profiles. This study aimed to determine the effects on VOC profiles of different storage times, at room temperature, prior to freezing, of sealed urine samples from healthy individuals. Analysis using Field Asymmetric Ion Motility Spectrometry (FAIMS) determined the alterations in VOC and total ion count profiles as a result of increasing room temperature storage times. Results indicated that increasing exposure time to room temperature prior to freezing had a threefold effect. Firstly, increased urinary VOC profile variability, with a plateau phase between 12 and 48 hours, before further degradation. Secondly, an increase in total ion count with time exposed to room temperature. Finally, a deterioration in VOCs with each sample run during the analysis process. This provides new insight into the effect of storage of urine samples for VOC analysis using FAIMS technology. Results of this study provide a recommendation for a 12-hour maximum duration at room temperature prior to storage.
Collapse
|
Journal Article |
5 |
8 |
16
|
Lacey L, Daulton E, Wicaksono A, Covington JA, Quenby S. Detection of Group B Streptococcus in pregnancy by vaginal volatile organic compound analysis: a prospective exploratory study. Transl Res 2020; 216:23-29. [PMID: 31585066 DOI: 10.1016/j.trsl.2019.09.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/08/2019] [Revised: 09/05/2019] [Accepted: 09/09/2019] [Indexed: 12/19/2022]
Abstract
Our objective was to assess whether volatile organic compound (VOC) analysis of vaginal swabs can detect maternal Group B Streptococcus (GBS) during pregnancy in a prospective exploratory study. Around 243 women attending a high-risk antenatal clinic at one university teaching hospital in the UK consented to take part and provide vaginal swabs throughout pregnancy. VOC analysis of vaginal swabs was undertaken and compared with the reference standard of GBS detected using enrichment culture method. The chemical components that emanated from the vaginal swabs were measured by gas chromatograph ion mobility spectrometry. This platform has both high sensitivity and good specificity to a range of chemical compounds. Our main outcome was to determine the sensitivity and specificity of VOC analysis for the detection of maternal GBS in vaginal swabs during pregnancy. Our study has demonstrated that the sensitivity and specificity of the VOC analysis by GC-IMS for the detection of GBS from vaginal swabs was 0.81 (95% confidence interval [CI], 0.71-0.89) and 0.97 (95% CI, 0.91-1) respectively. We conclude that the use of VOCs as biomarkers for the detection of maternal GBS in the vagina is a novel tool. As this test produces results within minutes and is of low unit test cost, it has the potential to be used in clinical settings, where fast diagnosis is important, for example, a patient in early labour.
Collapse
|
|
5 |
7 |
17
|
Clifton LA, Holt SA, Hughes AV, Daulton EL, Arunmanee W, Heinrich F, Khalid S, Jefferies D, Charlton TR, Webster JRP, Kinane CJ, Lakey JH. An Accurate In Vitro Model of the E. coli Envelope. ACTA ACUST UNITED AC 2015; 127:12120-12123. [PMID: 27346898 PMCID: PMC4871320 DOI: 10.1002/ange.201504287] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2015] [Revised: 08/07/2015] [Indexed: 11/12/2022]
Abstract
Gram‐negative bacteria are an increasingly serious source of antibiotic‐resistant infections, partly owing to their characteristic protective envelope. This complex, 20 nm thick barrier includes a highly impermeable, asymmetric bilayer outer membrane (OM), which plays a pivotal role in resisting antibacterial chemotherapy. Nevertheless, the OM molecular structure and its dynamics are poorly understood because the structure is difficult to recreate or study in vitro. The successful formation and characterization of a fully asymmetric model envelope using Langmuir–Blodgett and Langmuir–Schaefer methods is now reported. Neutron reflectivity and isotopic labeling confirmed the expected structure and asymmetry and showed that experiments with antibacterial proteins reproduced published in vivo behavior. By closely recreating natural OM behavior, this model provides a much needed robust system for antibiotic development.
Collapse
|
Journal Article |
10 |
6 |
18
|
Bosch S, Wintjens DSJ, Wicaksono A, Kuijvenhoven J, van der Hulst R, Stokkers P, Daulton E, Pierik MJ, Covington JA, de Meij TGJ, de Boer NKH. The faecal scent of inflammatory bowel disease: Detection and monitoring based on volatile organic compound analysis. Dig Liver Dis 2020; 52:745-752. [PMID: 32402741 DOI: 10.1016/j.dld.2020.03.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2019] [Revised: 03/07/2020] [Accepted: 03/10/2020] [Indexed: 12/11/2022]
Abstract
BACKGROUND Inflammatory bowel disease (IBD) is diagnosed and monitored using endoscopic assessment, which is invasive and costly. In this study, potential of faecal volatile organic compounds (VOC) analysis for IBD detection and identification of disease activity was evaluated. METHODS IBD patients visiting outpatient clinics of participating tertiary hospitals were included. Active disease was defined as FCP ≥250 mg/g, remission as FCP <100 mg/g with Harvey Bradshaw Index <4 for Crohn's disease (CD) or Simple Clinical Colitis Activity Index <3 for ulcerative colitis (UC). Healthy controls (HC) were patients without mucosal abnormalities during colonoscopy. Faecal samples were measured using gas chromatography-ion mobility spectrometry. RESULTS A total of 280 IBD patients collected 107 CDa, 84 CDr, 80 UCa and 63 UCr samples. Additionally, 227 HC provided one faecal sample. UC and CD were discriminated from HC with high accuracy (AUC (95%CI): UCa vs HC 0.96(0.94-0.99); UCr vs HC 0.95(0.93-0.98); CDa vs HC 0.96(0.94-0.99); CDr vs HC 0.95(0.93-0.98)). There were small differences between UC and CD (0.55(0.50-0.6)) and no differences between active disease and remission (UCa vs UCr 0.63(0.44-0.82); CDa vs CDr 0.52(0.39-0.65)). CONCLUSION Our study outcomes imply that faecal VOC analysis holds potential for identifying biomarkers for IBD detection but not for monitoring disease activity.
Collapse
|
Multicenter Study |
5 |
4 |
19
|
Chandrapalan S, Bosch S, Tyagi H, Daulton E, Cubiella J, Guardiola J, Kimani P, Mulder C, Covington J, Persaud K, de Meij TGJ, Altomare DF, Brenner H, de Boer NKH, Ricciardiello L, Arasaradnam RP. Editorial: volatile organic compound analysis to improve faecal immunochemical testing in the detection of colorectal cancer-Authors' reply. Aliment Pharmacol Ther 2021; 54:506-507. [PMID: 34331793 DOI: 10.1111/apt.16511] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Accepted: 06/16/2021] [Indexed: 12/17/2022]
|
Editorial |
4 |
1 |
20
|
Laird S, Debenham L, Chandla D, Chan C, Daulton E, Taylor J, Bhat P, Berry L, Munthali P, Covington JA. Breath Analysis of COVID-19 Patients in a Tertiary UK Hospital by Optical Spectrometry: The E-Nose CoVal Study. BIOSENSORS 2023; 13:bios13020165. [PMID: 36831932 PMCID: PMC9953365 DOI: 10.3390/bios13020165] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Revised: 01/06/2023] [Accepted: 01/11/2023] [Indexed: 05/31/2023]
Abstract
Throughout the SARS-CoV-2 pandemic, diagnostic technology played a crucial role in managing outbreaks on a national and global level. One diagnostic modality that has shown promise is breath analysis, due to its non-invasive nature and ability to give a rapid result. In this study, a portable FTIR (Fourier Transform Infra-Red) spectrometer was used to detect chemical components in the breath from Covid positive symptomatic and asymptomatic patients versus a control cohort of Covid negative patients. Eighty-five patients who had a nasopharyngeal polymerase chain reaction (PCR) test for the detection of SARS-CoV-2 within the last 5 days were recruited to the study (36 symptomatic PCR positive, 23 asymptomatic PCR positive and 26 asymptomatic PCR negative). Data analysis indicated significant difference between the groups, with SARS-CoV-2 present on PCR versus the negative PCR control group producing an area under the curve (AUC) of 0.87. Similar results were obtained comparing symptomatic versus control and asymptomatic versus control. The asymptomatic results were higher than the symptomatic (0.88 vs. 0.80 AUC). When analysing individual chemicals, we found ethanol, methanol and acetaldehyde were the most important, with higher concentrations in the COVID-19 group, with symptomatic patients being higher than asymptomatic patients. This study has shown that breath analysis can provide significant results that distinguish patients with or without COVID-19 disease/carriage.
Collapse
|
research-article |
2 |
1 |
21
|
Wesoly M, Daulton E, Jenkins S, van Amsterdam S, Clarkson J, Covington JA. Early Detection of Fusarium Basal Rot Infection in Onions and Shallots Based on VOC Profiles Analysis. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2024; 72:3664-3672. [PMID: 38320984 PMCID: PMC10885136 DOI: 10.1021/acs.jafc.3c06569] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/08/2024]
Abstract
Gas chromatography ion-mobility spectrometry (GC-IMS) technology is drawing increasing attention due to its high sensitivity, low drift, and capability for the identification of compounds. The noninvasive detection of plant pests and pathogens is an application area well suited to this technology. In this work, we employed GC-IMS technology for early detection of Fusarium basal rot in brown onion, red onion, and shallot bulbs and for tracking disease progression during storage. The volatile profiles of the infected and healthy control bulbs were characterized using GC-IMS and gas chromatography-time-of-flight mass spectrometry (GC-TOF-MS). GC-IMS data combined with principal component analysis and supervised methods provided discrimination between infected and healthy control bulbs as early as 1 day after incubation with the pathogen, classification regarding the proportion of infected to healthy bulbs in a sample, and prediction of the infection's duration with an average R2 = 0.92. Furthermore, GC-TOF-MS revealed several compounds, mostly sulfides and disulfides, that could be uniquely related to Fusarium basal rot infection.
Collapse
|
|
1 |
|
22
|
Nazareth J, Pan D, Kim JW, Leach J, Brosnan JG, Ahmed A, Brodrick E, Bird P, Wicaksono A, Daulton E, Tang JW, Williams C, Haldar P, Covington JA, Pareek M, Sahota A. Discriminatory ability of gas chromatography-ion mobility spectrometry to identify patients hospitalised with COVID-19 and predict prognosis. Open Forum Infect Dis 2022; 9:ofac509. [PMID: 36345428 PMCID: PMC9619573 DOI: 10.1093/ofid/ofac509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Accepted: 09/30/2022] [Indexed: 11/22/2022] Open
Abstract
Background Rapid diagnostic and prognostic tests for coronavirus disease (COVID-19) are urgently required. We aimed to evaluate the diagnostic and prognostic ability of breath analysis using gas chromatography–ion mobility spectrometry (GC-IMS) in hospitalized patients with COVID-19. Methods Between February and May 2021, we took 1 breath sample for analysis using GC-IMS from participants who were admitted to the hospital for COVID-19, participants who were admitted to the hospital for other respiratory infections, and symptom-free controls, at the University Hospitals of Leicester NHS Trust, United Kingdom. Demographic, clinical, and radiological data, including requirement for continuous positive airway pressure (CPAP) ventilation as a marker for severe disease in the COVID-19 group, were collected. Results A total of 113 participants were recruited into the study. Seventy-two (64%) were diagnosed with COVID-19, 20 (18%) were diagnosed with another respiratory infection, and 21 (19%) were healthy controls. Differentiation between participants with COVID-19 and those with other respiratory tract infections with GC-IMS was highly accurate (sensitivity/specificity, 0.80/0.88; area under the receiver operating characteristics curve [AUROC], 0.85; 95% CI, 0.74–0.96). GC-IMS was also moderately accurate at identifying those who subsequently required CPAP (sensitivity/specificity, 0.62/0.80; AUROC, 0.70; 95% CI, 0.53–0.87). Conclusions GC-IMS shows promise as both a diagnostic tool and a predictor of prognosis in hospitalized patients with COVID-19 and should be assessed further in larger studies.
Collapse
|
|
3 |
|
23
|
van Liere ELSA, Ramsoekh D, Daulton E, Dakkak M, van Lingen JM, Stewart TK, Bosch S, Carvalho B, Dekker E, Jacobs MAJM, Koornstra JJ, Kuijvenhoven JP, van Leerdam ME, de Meij TGJ, Meijer GA, Spaander MCW, Covington JA, de Boer NKH. Faecal Volatile Organic Compounds to Detect Colorectal Neoplasia in Lynch Syndrome-A Prospective Longitudinal Multicentre Study. Aliment Pharmacol Ther 2025; 61:145-158. [PMID: 39422092 PMCID: PMC11636173 DOI: 10.1111/apt.18328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/22/2024] [Revised: 08/26/2024] [Accepted: 09/25/2024] [Indexed: 10/19/2024]
Abstract
BACKGROUND Non-invasive biomarkers may reduce post-colonoscopy colorectal cancer (CRC) rates and colonoscopy overuse in Lynch syndrome. Unlike faecal immunochemical test (FIT), faecal volatile organic compounds (VOCs) may accurately detect both advanced and non-advanced colorectal neoplasia. AIM The aim of this study was to evaluate the potential of faecal VOCs-separately and with FIT-to guide optimal colonoscopy intervals in Lynch syndrome. METHODS Prospective longitudinal multicentre study in which individuals with Lynch syndrome collected faeces before and after high-quality surveillance colonoscopy. VOC-patterns were analysed using field asymmetric ion mobility spectrometry (FAIMS) and gas chromatography-ion mobility spectrometry (GC-IMS) followed by machine learning pipelines, and combined with FIT at 2.55 μg Hb/g faeces. Gas chromatography time-of-flight mass spectrometry analysed individual VOC abundance. RESULTS Among 200 included individuals (57% female, median 51 years), 62 had relevant neoplasia at colonoscopy: 3 CRC, 6 advanced adenoma (AA), 3 advanced serrated lesion (ASL), and 50 non-advanced adenoma (NAA). Respective sensitivity and negative predictive value for CRC and AA (and also ASL in case of FAIMS) were 100% and 100% using FAIMS (54% specificity), and 89% and 99% using GC-IMS (58% specificity). Respective sensitivity and specificity for any relevant neoplasia were 88% and 44% (FAIMS) and 84% and 28% (GC-IMS); accuracy did not significantly improve upon VOC-FIT. VOC-patterns differed before and after polypectomy (AUC 0.70). NAA showed decreased faecal abundance of butanal, 2-oxohexane, dimethyldisulphide and dimethyltrisulphide. CONCLUSIONS In Lynch syndrome, faecal VOCs may be a promising strategy for postponing colonoscopy and for follow-up after polypectomy. Our results serve as a stepping stone for large validation studies. TRIAL REGISTRATION NL8749.
Collapse
|
Multicenter Study |
1 |
|
24
|
Frerichs NM, Deianova N, El Manouni El Hassani S, Acharjee A, Quraishi MN, de Boode WP, Cossey V, Hulzebos CV, van Kaam AH, Kramer BW, d'Haens E, de Jonge WJ, Vijlbrief DC, van Weissenbruch MM, Daulton E, Wicaksono AN, Covington JA, Benninga MA, de Boer NKH, van Goudoever JB, Niemarkt HJ, de Meij TGJ. Fecal microbiota and volatile metabolome pattern alterations precede late-onset meningitis in preterm neonates. J Infect Dis 2024:jiae265. [PMID: 38781449 DOI: 10.1093/infdis/jiae265] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 03/12/2024] [Accepted: 05/16/2024] [Indexed: 05/25/2024] Open
Abstract
OBJECTIVE The fecal microbiota and metabolome are hypothesized to be altered before late-onset neonatal meningitis (LOM), in analogy to late-onset sepsis (LOS). The present study aimed to identify fecal microbiota composition and volatile metabolomics preceding LOM. METHODS Cases and gestational age-matched controls were selected from a prospective, longitudinal preterm cohort study (born <30 weeks' gestation) at nine neonatal intensive care units. The microbial composition (16S rRNA sequencing) and volatile metabolome (gas chromatography-ion mobility spectrometry (GC-IMS) and GC-time-of-flight-mass spectrometry (GC-TOF-MS)), were analyzed in fecal samples 1-10 days pre-LOM. RESULTS Of 1397 included infants, 21 were diagnosed with LOM (1.5%), and 19 with concomitant LOS (90%). Random Forest classification and MaAsLin2 analysis found similar microbiota features contribute to the discrimination of fecal pre-LOM samples versus controls. A Random Forest model based on six microbiota features accurately predicts LOM 1-3 days before diagnosis with an area under the curve (AUC) of 0.88 (n=147). Pattern recognition analysis by GC-IMS revealed an AUC of 0.70-0.76 (P<0.05) in the three days pre-LOM (n=92). No single discriminative metabolites were identified by GC-TOF-MS (n=66). CONCLUSION Infants with LOM could be accurately discriminated from controls based on preclinical microbiota composition, while alterations in the volatile metabolome were moderately associated with preclinical LOM.
Collapse
|
|
1 |
|
25
|
McFarlane M, Arasaradnam RP, Reed B, Daulton E, Wicaksono A, Tyagi H, Covington JA, Nwokolo C. Minimal Gluten Exposure Alters Urinary Volatile Organic Compounds in Stable Coeliac Disease. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22031290. [PMID: 35162037 PMCID: PMC8839331 DOI: 10.3390/s22031290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Revised: 02/01/2022] [Accepted: 02/03/2022] [Indexed: 05/04/2023]
Abstract
Coeliac disease (CD) patients are distinguishable from healthy individuals via urinary volatile organic compounds (VOCs) analysis. We exposed 20 stable CD patients on gluten-free diet (GFDs) to a 14-day, 3 g/day gluten challenge (GCh), and assessed urinary VOC changes. A control cohort of 20 patients continued on GFD. Urine samples from Days 0, 7, 14, 28 and 56 were analysed using Lonestar FAIMS and Markes Gas Chromatography-Time of Flight-Mass Spectrometer (GC-TOF-MS). VOC signatures on D (day) 7-56 were compared with D0. Statistical analysis was performed using R. In GCh patients, FAIMS revealed significant VOC differences for all time points compared to D0. GC-TOF-MS revealed significant changes at D7 and D14 only. In control samples, FAIMS revealed significant differences at D7 only. GC-TOF-MS detected no significant differences. Chemical analysis via GC-MS-TOF revealed 12 chemicals with significantly altered intensities at D7 vs. D0 for GCh patients. The alterations persisted for six chemicals at D14 and one (N-methyltaurine) remained altered after D14. This low-dose, short-duration challenge was well tolerated. FAIMS and GC-TOF-MS detected VOC signature changes in CD patients when undergoing a minimal GCh. These findings suggest urinary VOCs could have a role in monitoring dietary compliance in CD patients.
Collapse
|
research-article |
3 |
|