1
|
Targeting Local Recurrence After Surgery With MRI Imaging for Prostate Cancer in the Setting of Salvage Radiation Therapy. Front Oncol 2022; 12:775387. [PMID: 35242702 PMCID: PMC8887697 DOI: 10.3389/fonc.2022.775387] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Accepted: 01/05/2022] [Indexed: 11/18/2022] Open
Abstract
Magnetic resonance imaging (MRI) is being increasingly used for imaging suspected recurrence in prostate cancer therapy. Functional MRI with diffusion and perfusion imaging has the potential to demonstrate local recurrence even at low PSA value. Detection of recurrence can modify the management of postprostatectomy biochemical recurrence. MRI scan acquired before salvage radiotherapy is useful for the localization of recurrent tumors and also in the delineation of the target volume. The objective of this review is to assess the role and potential impact of MRI in targeting local recurrence after surgery for prostate cancer in the setting of salvage radiation therapy.
Collapse
|
2
|
Use of a Biodegradable, Contrast-Filled Rectal Spacer Balloon in Intensity-Modulated Radiotherapy for Intermediate-Risk Prostate Cancer Patients: Dosimetric Gains in the BioPro-RCMI-1505 Study. Front Oncol 2021; 11:701998. [PMID: 34513681 PMCID: PMC8427159 DOI: 10.3389/fonc.2021.701998] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Accepted: 07/21/2021] [Indexed: 01/12/2023] Open
Abstract
Background/purpose Dose-escalated external beam radiotherapy (RT) is effective in the control of prostate cancer but is associated with a greater incidence of rectal adverse events. We assessed the dosimetric gain and safety profile associated with implantation of a new biodegradable rectal spacer balloon. Materials/methods Patients scheduled for image-guided, intensity-modulated RT for intermediate-risk prostate cancer were prospectively included in the French multicenter BioPro-RCMI-1505 study (NCT02478112). We evaluated the dosimetric gain, implantation feasibility, adverse events (AEs), and prostate-cancer-specific quality of life associated with use of the balloon spacer. Results After a scheduled review of the initial recruitment target of 50 patients by the study's independent data monitoring committee (IDMC), a total of 24 patients (including 22 with dosimetry data) were included by a single center between November 2016 and May 2018. The interventional radiologist who implanted the balloons considered that 86% of the procedures were easy. 20 of the 24 patients (83.3%) received IMRT and 4 (16.7%) received volumetric modulated arc therapy (78-80 Gy delivered in 39 fractions). The dosimetric gains associated with spacer implantation were highly significant (p<0.001) for most variables. For the rectum, the median (range) relative gain ranged from 15.4% (-9.2-47.5) for D20cc to 91.4% (36.8-100.0) for V70 Gy (%). 15 patients (62%) experienced an acute grade 1 AE, 8 (33%) experienced a late grade 1 AE, 1 (4.2%) experienced an acute grade 2 AE, and 3 experienced a late grade 2 AE. No grade 3 AEs were reported. Quality of life was good at baseline (except for sexual activity) and did not markedly worsen during RT and up to 24 months afterwards. Conclusion The use of a biodegradable rectal spacer balloon is safe, effective and associated with dosimetric gains in modern RT for intermediate-risk prostate cancer.
Collapse
|
3
|
Left atrial appendage occlusion simulation based on three-dimensional printing: new insights into outcome and technique. EUROINTERVENTION 2019. [PMID: 29537376 DOI: 10.4244/eij-d-17-00970] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
AIMS The aim of this study was to assess the predictive value of simulation based on 3D-printed models before left atrial appendage occlusion (LAAO) for peri-device leaks (PDL) and the impact on procedural outcomes compared to conventional imaging. METHODS AND RESULTS Seventy-six patients referred for LAAO with double disc device underwent construction of a 3D-printed LA model using flexible photopolymer resin. An implant simulation was performed retrospectively in Group 1 (55 patients), blinded to implanted device size, and prospectively in Group 2 (21 patients). In Group 1, an off-axis device position occurred in 14 patients (25%) and the incidence of PDL was 27% (15 patients); mismatch between model and device size was the best predictor (area under the curve 0.88, CI: 0.77-0.99). When using 3D simulation prospectively, mean prosthesis number per patient (1.05±0.21 vs. 1.20±0.52, p=0.04) and incidence of leaks (5% vs. 27%, p<0.01) were reduced compared to conventional imaging alone, as well as fluoroscopy time (19 mins [13.4-23] vs. 13.5 mins [11.1-15], p=0.012) and total fluoroscopy dose (7,291 [1,811-12,734] vs. 1,978 (1,548-4,800) mGy·cm2, p=0.029). CONCLUSIONS 3D-printed patient-specific adaptive and flexible LA models improve LAAO double disc device sizing. This can potentially reduce procedure time and the number of prostheses employed per patient.
Collapse
|
4
|
Accuracy of the preoperative PSA level for predicting clinically significant incidental transitional zone-prostate cancer before endoscopic enucleation of very large adenoma. World J Urol 2019; 38:993-1000. [PMID: 31139906 DOI: 10.1007/s00345-019-02823-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2019] [Accepted: 05/24/2019] [Indexed: 12/25/2022] Open
Abstract
OBJECTIVE To analyse the accuracy of high preoperative PSA levels for predicting transitional zone incidental PCa (TZ-PCa) in men with very large prostates. MATERIALS AND METHODS Perioperative data from 375 consecutive patients who underwent endoscopic enucleation of the prostate (EEP) for benign prostatic obstruction between July 2013 and December 2018 were retrospectively reviewed. Patients were stratified into three groups according to the preoperative PSA level: low-PSA (< 4 ng/mL), intermediate-PSA (4 ≤ PSA < 10 ng/mL) and high-PSA (≥ 10 ng/mL). Men in each group were propensity score matched by age, 5α-reductase inhibitor (5-ARI) use, prostate volume and mpMRI. The TZ-PCa incidence rate was retrospectively compared by preoperative PSA level in a propensity score model including all predetermined variables. RESULTS Age, prostate volume, 5-ARI use were similar between patient groups. The median PSA levels in the low-, intermediate- and high-PSA groups were 3 [2.3; 3.4], 6.6 [5.3; 8.1] and 12.7 [11; 16.7] ng/mL, respectively. The median prostate volume was > 100 grams in all groups (108, 105 and 120 cc, respectively). The T1a-Gleason 6 incidental TZ-PCa rate was statistically comparable between the three groups (3.4, 5.1 and 8.6% in the low-, intermediate- and high-PSA groups, respectively). The detection rate of clinically significant TZ-PCa was low for preoperative PSA levels > 4 ng/mL (1.7%); with no difference between the intermediate- and high-PSA groups. CONCLUSION In men with large glands, the clinically significant incidental TZ-PCa detection rate was similar regardless of the preoperative PSA level stratum. Such details may help with patient counselling during BPH surgical management.
Collapse
|
5
|
Is mean heart dose a relevant surrogate parameter of left ventricle and coronary arteries exposure during breast cancer radiotherapy: a dosimetric evaluation based on individually-determined radiation dose (BACCARAT study). Radiat Oncol 2019; 14:29. [PMID: 30732640 PMCID: PMC6367844 DOI: 10.1186/s13014-019-1234-z] [Citation(s) in RCA: 92] [Impact Index Per Article: 18.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2018] [Accepted: 01/28/2019] [Indexed: 12/25/2022] Open
Abstract
Background Intra-individual heterogeneity of cardiac exposure is an issue in breast cancer (BC) radiotherapy that was poorly considered in previous cardiotoxicity studies mainly based on mean heart dose (MHD). This dosimetric study analyzes the distribution of individually-determined radiation doses to the heart and its substructures including coronary arteries and evaluate whether MHD is a relevant surrogate parameter of dose for these substructures. Methods Data were collected from the BACCARAT prospective study that included left or right unilateral BC patients treated with 3D-Conformal Radiotherapy (RT) between 2015 and 2017 and followed-up for 2 years with repeated cardiac imaging examinations. A coronary computed tomography angiography (CCTA) was performed before RT for all patients. Registration of the planning CT and CCTA images allowed delineation of the coronary arteries on the planning CT images. Using the 3D dose matrix generated during treatment planning and the added coronary contours, dose distributions were generated for whole heart and the following substructures: left ventricle (LV), left main coronary artery (LMCA), left anterior descending artery (LAD), left circumflex artery (LCX) and right coronary artery (RCA). A descriptive analysis of the physical doses in Gray (Gy) was performed, Dmean was the volume-weighted mean dose. Results Dose distributions were generated for 89 left-sided BC patients (MHD = 2.9 ± 1.5 Gy, Dmean_LAD = 15.7 ± 3.1 Gy) and 15 right-sided BC patients (MHD = 0.5 ± 0.1 Gy; Dmean_RCA = 1.2 ± 0.4 Gy). For left-sided BC patients, the ratio Dmean_LAD/MHD was around 5. Pearson correlation coefficients between MHD and Dmean for delineated substructures were all statistically significant. However, for all substructures, the coefficient of determination R2 indicated that the proportion of the variance in Dmean of the substructure predictable from MHD was moderate to low (in particular R2 = 0.45 for LAD). Among left-sided BC patients with MHD < 3Gy, 56% of patients could nevertheless receive LAD doses above 40Gy (V40 > 0). Conclusion Our study illustrates that MHD is not enough to predict with confidence individual patient dose to the LV and coronary arteries, in particular the LAD. For precise radiotherapy-induced cardiotoxicity studies it would be necessary to consider the distribution of doses within these cardiac substructures rather than just the MHD. Trial registration ClinicalTrials.gov: NCT02605512, Registered 6 November 2015 - Retrospectively registered.
Collapse
|
6
|
Cardiac radiation exposure associated with breast cancer radiotherapy: Dose distribution to the heart substructures and coronary arteries (BACCARAT study). ARCHIVES OF CARDIOVASCULAR DISEASES SUPPLEMENTS 2019. [DOI: 10.1016/j.acvdsp.2018.10.344] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
7
|
Precision Matters in MR Imaging–targeted Prostate Biopsies: Evidence from a Prospective Study of Cognitive and Elastic Fusion Registration Transrectal Biopsies. Radiology 2018; 287:534-542. [DOI: 10.1148/radiol.2017162916] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
8
|
Escalade de dose lors d’une radiothérapie de rattrapage des récidives locales de cancer prostatique détectées par IRM après prostatectomie radicale. Cancer Radiother 2017. [DOI: 10.1016/j.canrad.2017.08.072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
9
|
Utilisations des espaceurs pour la radiothérapie de la prostate dans une série de 46 patients. Cancer Radiother 2017. [DOI: 10.1016/j.canrad.2017.08.074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
10
|
Évaluation et comparaison de la pose dans la cloison recto-prostatique des trois espaceurs disponibles en France pour la radiothérapie du cancer de la prostate. Cancer Radiother 2016. [DOI: 10.1016/j.canrad.2016.08.060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
11
|
Are Magnetic Resonance Imaging-Transrectal Ultrasound Guided Targeted Biopsies Noninferior to Transrectal Ultrasound Guided Systematic Biopsies for the Detection of Prostate Cancer? J Urol 2016; 196:1069-75. [DOI: 10.1016/j.juro.2016.04.003] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/03/2016] [Indexed: 11/28/2022]
|
12
|
Trois biopsies ciblées par fusion d’image IRM – échographie sont-elles suffisantes pour diagnostiquer un cancer de la prostate en présence d’une image IRM prostatique suspecte et isolée ? Résultats de l’étude prospective multicentrique MURIELLE. Prog Urol 2015; 25:831. [DOI: 10.1016/j.purol.2015.08.229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
13
|
Évaluation par IRM de la pose d’un espaceur dans la cloison rectoprostatique (ballon biodégradable BioProtect™) pour la radiothérapie du cancer de la prostate. Cancer Radiother 2015. [DOI: 10.1016/j.canrad.2015.07.130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
14
|
Prostate Imaging Reporting and Data System and Likert Scoring System: Multiparametric MR Imaging Validation Study to Screen Patients for Initial Biopsy. Radiology 2015; 275:458-68. [PMID: 25599415 DOI: 10.1148/radiol.14140184] [Citation(s) in RCA: 87] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
PURPOSE To compare the diagnostic performance of the magnetic resonance (MR) imaging-based Prostate Imaging Reporting and Data System (PI-RADS) and a Likert scale in the detection of prostate cancer in a cohort of patients undergoing initial prostate biopsy. MATERIALS AND METHODS This institutional review board-approved two-center prospective study included 118 patients with normal digital rectal examination (DRE) results but elevated prostate-specific antigen (PSA) levels (4-20 ng/mL) who were referred for initial prostate biopsies and had one suspicious (Likert scale score, ≥3) focus at prebiopsy 1.5-T multiparametric MR imaging performed with T2-weighted, diffusion-weighted [DW], and dynamic contrast material-enhanced imaging. Targeted core biopsies and random systematic core biopsies were performed. The elementary unit for analysis was the core. Relationships were assessed by using the Mann-Whitney U test. Yates corrected and Pearson χ(2) tests were used to evaluate categoric variables. A training set was randomly drawn to construct the receiver operating characteristic curves for the summed PI-RADS scores and for the Likert scale scores. The thresholds to recommend biopsy were obtained from the Youden J statistics and were tested in the remaining validation set in terms of predictive characteristics. Interobserver variability was analyzed by using weighed κ statistics in a random set of 50 patients. RESULTS Higher T2-weighted, DW, and dynamic contrast-enhanced imaging PI-RADS scores were observed in areas that yielded cancer-positive cores. The percentage of positive cores increased with the sum of scores aggregated in five classes as follows: For summed PI-RADS scores of 3-5, the percentage of positive cores was 2.3%; for scores of 6-8, it was 5.8%; for scores of 9 or 10, it was 24.7%; for scores of 11 or 12, it was 51.8%; and for scores of 13-15, it was 72.1% (P for trend, <.0001). For the threshold of summed PI-RADS scores of 9 or greater, sensitivity was 86.6%, specificity was 82.4%, the positive predictive value was 52.4%, the negative predictive value was 96.5%, and accuracy was 83.2%. The respective data for Likert scale scores of 3 or greater were 93.8%, 73.6%, 44.3%, 98.1%, and 73.3%. Good interobserver agreement was observed for the Likert scale (κ = 0.80) and the summed PI-RADS (κ = 0.73) scoring systems. CONCLUSION PI-RADS provided the site-specific stratified risk of cancer-positive cores in biopsy-naive men with normal DRE results and elevated PSA levels. There was no significant difference between summed PI-RADS scores of 9 or greater and Likert scale scores of 3 or greater in the detection of cancer in the peripheral zone.
Collapse
|
15
|
Assessment of the learning curves for photoselective vaporization of the prostate using GreenLight™ 180-Watt-XPS laser therapy: defining the intra-operative parameters within a prospective cohort. World J Urol 2013; 32:539-44. [PMID: 24072009 DOI: 10.1007/s00345-013-1163-7] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2013] [Accepted: 08/27/2013] [Indexed: 02/02/2023] Open
Abstract
PURPOSE To assess the learning curves for the intra-operative parameters of the GreenLight™ 180-W XPS for photoselective vaporization of the prostate (PVP). METHODS A prospective study was conducted on 200 men who underwent PVP using the GreenLight™ 180-W XPS over 20 months. The population was divided into four consecutive equal groups. Evolution of lasing parameters was the main endpoint to reach an average energy of 5 kJ per prostate volume and to reach a lasing time/operative time (LT/OT) ratio of 66-80 %. Changes in the IPSS and prostate volume were also evaluated 12 weeks later. RESULTS Total energy delivered (energy/ml of prostate) and the LT/OT ratio significantly increased over time (p < 0.05). Urinary function significantly improved from baseline in all groups. The first lasing parameter endpoint was reached after the 75th patient (group 1) and the second endpoint (LT/OT ratio) after the 125th patient (group 3). Only the PSA level (p = 0.04) and prostate volume (p < 0.0001) decreased significantly in the 3rd and the 4th group. Post-operative complications occurred in 20 % of patients, which were primarily Clavien-Dindo grades 1 and 2, though there were no statistical differences between the four groups (p = 0.62). In-hospital stay and time to catheter removal were significantly shorter in the 3rd and 4th group. CONCLUSIONS The current study assessed the PVP learning curves within multiple intra-operative parameters. The PVP learning curves required at least 120 procedures until it met all intra-operative parameters of experts in this field.
Collapse
|
16
|
Inverted stress (Takotsubo) cardiomyopathy following Caesarean section: Insights from cardiac magnetic resonance. Int J Cardiol 2013. [DOI: 10.1016/j.ijcard.2012.10.087] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
17
|
Assessment of diastolic function from velocity-encoded cardiac magnetic resonance data in patients with hypertrophic cardiomyopathy. J Cardiovasc Magn Reson 2013. [PMCID: PMC3559735 DOI: 10.1186/1532-429x-15-s1-p170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
|
18
|
071: Assessment of diastolic function from velocity-encoded cardiac magnetic resonance data in patients with hypertrophic cardiomyopathy. ARCHIVES OF CARDIOVASCULAR DISEASES SUPPLEMENTS 2013. [DOI: 10.1016/s1878-6480(13)71001-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
19
|
Age-related variations in left ventricular diastolic parameters assessed automatically from phase-contrast cardiovascular magnetic resonance data: comparison against doppler echocardiography. J Cardiovasc Magn Reson 2012. [PMCID: PMC3305009 DOI: 10.1186/1532-429x-14-s1-p155] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
20
|
Evaluation of aortic valve stenosis using cardiovascular magnetic resonance: comparison of an original semiautomated analysis of phase-contrast cardiovascular magnetic resonance with Doppler echocardiography. Circ Cardiovasc Imaging 2012; 5:604-12. [PMID: 22798520 DOI: 10.1161/circimaging.111.971218] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Accurate quantification of aortic valve stenosis (AVS) is needed for relevant management decisions. However, transthoracic Doppler echocardiography (TTE) remains inconclusive in a significant number of patients. Previous studies demonstrated the usefulness of phase-contrast cardiovascular magnetic resonance (PC-CMR) in noninvasive AVS evaluation. We hypothesized that semiautomated analysis of aortic hemodynamics from PC-CMR might provide reproducible and accurate evaluation of aortic valve area (AVA), aortic velocities, and gradients in agreement with TTE. METHODS AND RESULTS We studied 53 AVS patients (AVA(TTE)=0.87±0.44 cm(2)) and 21 controls (AVA(TTE)=2.96±0.59 cm(2)) who had TTE and PC-CMR of aortic valve and left ventricular outflow tract on the same day. PC-CMR data analysis included left ventricular outflow tract and aortic valve segmentation, and extraction of velocities, gradients, and flow rates. Three AVA measures were performed: AVA(CMR1) based on Hakki formula, AVA(CMR2) based on continuity equation, AVA(CMR3) simplified continuity equation=left ventricular outflow tract peak flow rate/aortic peak velocity. Our analysis was reproducible, as reflected by low interoperator variability (<4.56±4.40%). Comparison of PC-CMR and TTE aortic peak velocities and mean gradients resulted in good agreement (r=0.92 with mean bias=-29±62 cm/s and r=0.86 with mean bias=-12±15 mm Hg, respectively). Although good agreement was found between TTE and continuity equation-based CMR-AVA (r>0.94 and mean bias=-0.01±0.38 cm(2) for AVA(CMR2), -0.09±0.28 cm(2) for AVA(CMR3)), AVA(CMR1) values were lower than AVA(TTE) especially for higher AVA (mean bias=-0.45±0.52 cm(2)). Besides, ability of PC-CMR to detect severe AVS, defined by TTE, provided the best results for continuity equation-based methods (accuracy >94%). CONCLUSIONS Our PC-CMR semiautomated AVS evaluation provided reproducible measurements that accurately detected severe AVS and were in good agreement with TTE.
Collapse
|
21
|
141 Age-related variations of diastolic parameters assessed by Doppler echocardiography and phase-contrast cardiovascular magnetic resonance in asymptomatic volunteers. ARCHIVES OF CARDIOVASCULAR DISEASES SUPPLEMENTS 2012. [DOI: 10.1016/s1878-6480(12)70537-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
22
|
Evaluation of aortic valve stenosis from Phase-Contrast Magnetic Resonance data using a new automated segmentation and analysis method: Comparison against Doppler Echocardiography. J Cardiovasc Magn Reson 2011. [PMCID: PMC3106824 DOI: 10.1186/1532-429x-13-s1-o30] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
23
|
Combined Retrograde Stent-Graft Placement and Surgical Repair for a Stanford Type A Aortic Dissection. J Endovasc Ther 2010; 17:755-8. [DOI: 10.1583/10-3194.1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
24
|
Recurrent liver abscess secondary to ingested fish bone migration: report of a case. Surg Today 2008; 38:572-5. [PMID: 18516543 DOI: 10.1007/s00595-007-3670-x] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2007] [Accepted: 07/29/2007] [Indexed: 12/28/2022]
Abstract
Pyogenic liver abscess is an unusual cause of fever and abdominal pain, but it is potentially fatal. It is rarely caused by a local event, but rather by hematogenous dissemination or biliary tract disease. We report an uncommon case of liver abscess caused by the migration of a fish bone through the gastrointestinal wall.
Collapse
|
25
|
Abstract
Churg-Strauss syndrome and Wegener granulomatosis are the two principal ANCA-associated vasculitides. Cardiac damage is frequent and prognosis poor. This damage is often subclinical initially and undetectable with standard cardiac imaging techniques (such as cardiac ultrasound or myocardial scintigraphy). Cardiac MRI permits early diagnosis of the different types of cardiac damage (myocarditis, pericarditis, and impaired myocardiac perfusion) that may occur during ANCA-associated vasculitis, even before the onset of symptoms. Early detection of this cardiac damage is crucial for it enables faster implementation of aggressive treatment, which may significantly improve disease prognosis. The widespread, even routine, practice of cardiac MRI in patients with ANCA-associated vasculitis thus seems justified, for this noninvasive examination provides essential diagnostic and prognostic information and helps guide therapeutic management.
Collapse
|
26
|
[Coronary artery implantation and course abnormalities: the contribution of multislice CT]. JOURNAL DE RADIOLOGIE 2007; 88:39-46. [PMID: 17299365 DOI: 10.1016/s0221-0363(07)89787-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Abnormalities in coronary artery origin and course are rare and often asymptomatic. However, visualizing them is of great interest because they can be responsible for iatrogenic trauma during cardiac surgery, and, for some of them, for myocardial infarction, which can lead to sudden death. We show the contribution of multislice CT in the positive diagnosis of these anatomic variations and in the differential diagnosis between benign and malignant forms, potentially responsible for myocardial ischemia.
Collapse
|