1
|
Lichtwark GA, Bougoulias K, Wilson AM. Muscle fascicle and series elastic element length changes along the length of the human gastrocnemius during walking and running. J Biomech 2007; 40:157-64. [PMID: 16364330 DOI: 10.1016/j.jbiomech.2005.10.035] [Citation(s) in RCA: 299] [Impact Index Per Article: 16.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2005] [Accepted: 10/27/2005] [Indexed: 11/27/2022]
Abstract
Ultrasound imaging has recently been used to distinguish the length changes of muscle fascicles from those of the whole muscle tendon complex during real life movements. The complicated three-dimensional architecture of pennate muscles can however cause heterogeneity in the length changes along the length of a muscle. Here we use ultrasonography to examine muscle fascicle length and pennation angle changes at proximal, distal and midbelly sites of the human gastrocnemius medialis (GM) muscle during walking (4.5 km/h) and running (7.5 km/h) on a treadmill. The results of this study have shown that muscle fascicles perform the same actions along the length of the human GM muscle during locomotion. However the distal fascicles tend to shorten more and act at greater pennation angles than the more proximal fascicles. Muscle fascicles acted relatively isometrically during the stance phase during walking, however during running the fascicles shortened throughout the stance phase, which corresponded to an increase in the strain of the series elastic elements (SEEs) (consisting of the Achilles tendon and aponeurosis). Measurement of the fascicle length changes at the midbelly level provided a good approximation of the average fascicle length changes across the length of the muscle. The compliance of the SEE allows the muscle fascicles to shorten at a much slower speed, more concomitant with their optimal speed for maximal power output and efficiency, with high velocity shortening during take off in both walking and running achieved by recoil of the SEE.
Collapse
|
|
18 |
299 |
2
|
Lichtwark GA, Wilson AM. In vivo mechanical properties of the human Achilles tendon during one-legged hopping. J Exp Biol 2005; 208:4715-25. [PMID: 16326953 DOI: 10.1242/jeb.01950] [Citation(s) in RCA: 259] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
SUMMARY
Compliant tendons act as energy stores, which benefit the energetics and power output of a muscle–tendon unit. However the compliance of tendon and the material properties may vary between individuals and hence alter the energy storing capacity of the tendon. We aimed to determine the in vivo Achilles tendon (AT) stress and strain during one-legged hopping and hence the contribution of elastic recoil to mechanical energy changes. We simultaneously measured the length of the Achilles tendon from the muscle–tendon junction to the insertion on the calcaneous and the approximate AT force in ten male participants. The position of the muscle–tendon junction was determined using ultrasound images that were projected into three-dimensional space. Achilles tendon force was measured using inverse dynamics. The results demonstrated that one-legged hopping elicited high tendon strains and that the force–length relationship of the whole tendon is relatively linear, particularly at high strains. The stiffness, elastic modulus and hysteresis varied across the population(inter-quartile range of 145–231 N mm–1,0.67–1.07 GPa and 17–35%, respectively). These values are within the reported biological range. An average of 38 J of energy was recovered from the elastic recoil of the tendon, which contributes 16% of the total average mechanical work of the hop (254 J). The high strains measured here (average peak strain was 8.3%) and in other studies may be possible due to the complex architecture of the Achilles tendon; however, prolonged hopping may well cause tendon damage. In conclusion, the properties of the elastic Achilles tendon can contribute significantly to the total mechanical work of the body during one-legged hopping; however, individual variation in the properties of the tendon vary the energy storing capacity of this structure.
Collapse
|
|
20 |
259 |
3
|
Lichtwark GA, Wilson AM. Interactions between the human gastrocnemius muscle and the Achilles tendon during incline, level and decline locomotion. J Exp Biol 2006; 209:4379-88. [PMID: 17050853 DOI: 10.1242/jeb.02434] [Citation(s) in RCA: 242] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
SUMMARY
Muscles are required to perform or absorb mechanical work under different conditions. However the ability of a muscle to do this depends on the interaction between its contractile components and its elastic components. In the present study we have used ultrasound to examine the length changes of the gastrocnemius medialis muscle fascicle along with those of the elastic Achilles tendon during locomotion under different incline conditions. Six male participants walked (at 5 km h-1) on a treadmill at grades of -10%,0% and 10% and ran (at 10 km h-1) at grades of 0% and 10%, whilst simultaneous ultrasound, electromyography and kinematics were recorded. In both walking and running, force was developed isometrically; however,increases in incline increased the muscle fascicle length at which force was developed. Force was developed at shorter muscle lengths for running when compared to walking. Substantial levels of Achilles tendon strain were recorded in both walking and running conditions, which allowed the muscle fascicles to act at speeds more favourable for power production. In all conditions, positive work was performed by the muscle. The measurements suggest that there is very little change in the function of the muscle fascicles at different slopes or speeds, despite changes in the required external work. This may be a consequence of the role of this biarticular muscle or of the load sharing between the other muscles of the triceps surae.
Collapse
|
|
19 |
242 |
4
|
Lichtwark GA, Wilson AM. Is Achilles tendon compliance optimised for maximum muscle efficiency during locomotion? J Biomech 2007; 40:1768-75. [PMID: 17101140 DOI: 10.1016/j.jbiomech.2006.07.025] [Citation(s) in RCA: 160] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2006] [Accepted: 07/31/2006] [Indexed: 11/25/2022]
Abstract
Tendon elasticity is important for economical locomotion; however it is unknown whether tendon stiffness is appropriate to achieve an optimal efficiency in various muscles. Here we test the hypothesis that the Achilles tendon is of an appropriate stiffness to maximise medial gastrocnemius muscle efficiency during locomotion with different power requirements. To test this hypothesis we used a three element Hill muscle model to determine how muscle fascicles would be required to change length if the series elastic element stiffness is varied, whilst the limb kinematics and muscle properties are held constant. We applied a model of muscle energetics to these data to predict muscle efficiency for a range of stiffness values in both walking and running conditions. We also compared the model results to in vivo data collected using ultrasonography. The muscle model predicted that optimal series elastic element stiffness for maximising efficiency is equal or slightly higher than that of the average Achilles tendon in running and walking, respectively. Although the peak efficiency values for running (26%) and walking (27%) are similar, the range of stiffness values achieving high efficiency in running is much smaller than that during walking. These results suggest that a compliant tendon, such as the Achilles tendon, is required for efficient running. Such a finding is important, because it describes how the stiffness of a tendon may be adapted to achieve optimal efficiency for particular athletic pursuits. The influence of varying tendon stiffness on kinematic performance may, however, play an important role in determining the efficiency of the muscle.
Collapse
|
|
18 |
160 |
5
|
Rees JD, Lichtwark GA, Wolman RL, Wilson AM. The mechanism for efficacy of eccentric loading in Achilles tendon injury; an in vivo study in humans. Rheumatology (Oxford) 2008; 47:1493-7. [PMID: 18647799 DOI: 10.1093/rheumatology/ken262] [Citation(s) in RCA: 80] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
OBJECTIVE Degenerative disorders of tendons present an enormous clinical challenge. They are extremely common, prone to recur and existing medical and surgical treatments are generally unsatisfactory. Recently eccentric, but not concentric, exercises have been shown to be highly effective in managing tendinopathy of the Achilles (and other) tendons. The mechanism for the efficacy of these exercises is unknown although it has been speculated that forces generated during eccentric loading are of a greater magnitude. Our objective was to determine the mechanism for the beneficial effect of eccentric exercise in Achilles tendinopathy. METHODS Seven healthy volunteers performed eccentric and concentric loading exercises for the Achilles tendon. Tendon force and length changes were determined using a combination of motion analysis, force plate data and real-time ultrasound. RESULTS There was no significant difference in peak tendon force or tendon length change when comparing eccentric with concentric exercises. However, high-frequency oscillations in tendon force occurred in all subjects during eccentric exercises but were rare in concentric exercises (P < 0.0001). CONCLUSION These oscillations provide a mechanism to explain the therapeutic benefit of eccentric loading in Achilles tendinopathy and parallels recent evidence from bone remodelling, where the frequency of the loading cycles is of more significance than the absolute magnitude of the force.
Collapse
|
Journal Article |
17 |
80 |
6
|
Lichtwark GA, Barclay CJ. The influence of tendon compliance on muscle power output and efficiency during cyclic contractions. ACTA ACUST UNITED AC 2010; 213:707-14. [PMID: 20154185 DOI: 10.1242/jeb.038026] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Muscle power output and efficiency during cyclical contractions are influenced by the timing and duration of stimulation of the muscle and the interaction of the muscle with its mechanical environment. It has been suggested that tendon compliance may reduce the energy required for power production from the muscle by reducing the required shortening of the muscle fibres. Theoretically this may allow the muscle to maintain both high power output and efficiency during cyclical contraction; however, this has yet to be demonstrated experimentally. To investigate how tendon compliance might act to increase muscle power output and/or efficiency, we attached artificial tendons of varying compliance to muscle fibre bundles in vitro and measured power output and mechanical efficiency during stretch-shorten cycles (2 Hz) with a range of stretch amplitudes and stimulation patterns. The results showed that peak power, average power output and efficiency (none of which can have direct contributions from the compliant tendon) all increased with increasing tendon compliance, presumably due to the tendon acting to minimise muscle energy use by allowing the muscle fibres to shorten at optimal speeds. Matching highly compliant tendons with a sufficiently large amplitude length change and appropriate stimulation pattern significantly increased the net muscle efficiency compared with stiff tendons acting at the same frequency. The maximum efficiency for compliant tendons was also similar to the highest value measured under constant velocity and force conditions, which suggests that tendon compliance can maximise muscle efficiency in the conditions tested here. These results provide experimental evidence that during constrained cyclical contractions, muscle power and efficiency can be enhanced with compliant tendons.
Collapse
|
Research Support, Non-U.S. Gov't |
15 |
57 |
7
|
Carty CP, Barrett RS, Cronin NJ, Lichtwark GA, Mills PM. Lower Limb Muscle Weakness Predicts Use of a Multiple- Versus Single-Step Strategy to Recover From Forward Loss of Balance in Older Adults. J Gerontol A Biol Sci Med Sci 2012; 67:1246-52. [DOI: 10.1093/gerona/gls149] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
|
13 |
55 |
8
|
Lichtwark GA, Wilson AM. A modified Hill muscle model that predicts muscle power output and efficiency during sinusoidal length changes. ACTA ACUST UNITED AC 2006; 208:2831-43. [PMID: 16043588 DOI: 10.1242/jeb.01709] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
The power output of a muscle and its efficiency vary widely under different activation conditions. This is partially due to the complex interaction between the contractile component of a muscle and the serial elasticity. We investigated the relationship between power output and efficiency of muscle by developing a model to predict the power output and efficiency of muscles under varying activation conditions during cyclical length changes. A comparison to experimental data from two different muscle types suggests that the model can effectively predict the time course of force and mechanical energetic output of muscle for a wide range of contraction conditions, particularly during activation of the muscle. With fixed activation properties, discrepancies in the work output between the model and the experimental results were greatest at the faster and slower cycle frequencies than that for which the model was optimised. Further optimisation of the activation properties across each individual cycle frequency examined demonstrated that a change in the relationship between the concentration of the activator (Ca2+) and the activation level could account for these discrepancies. The variation in activation properties with speed provides evidence for the phenomenon of shortening deactivation, whereby at higher speeds of contraction the muscle deactivates at a faster rate. The results of this study demonstrate that predictions about the mechanics and energetics of muscle are possible when sufficient information is known about the specific muscle.
Collapse
|
Research Support, Non-U.S. Gov't |
19 |
52 |
9
|
Lichtwark GA, Wilson AM. Effects of series elasticity and activation conditions on muscle power output and efficiency. J Exp Biol 2005; 208:2845-53. [PMID: 16043589 DOI: 10.1242/jeb.01710] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
SUMMARYThe activation of a muscle depends on the function that it is performing and on the architectural properties of that muscle; the two are inextricably linked. Activation conditions such as activation timing, duration and amplitude can be varied throughout a cyclical movement (such as locomotion)and the length change of the whole muscle tendon unit (MTU) can also be varied. Architecturally, muscles have a range of fibre lengths, maximum force-producing capabilities and stiffness of the series elastic element(SEE). In the present work we use a model to explore the relationship between power output and efficiency of a muscle across a range of contraction conditions. We have also examined the mechanical and energetic effects of changing muscle architecture within the model. Our results indicate that whilst there are clear optimal conditions for achieving maximum power output and maximum efficiency, the design of the muscle allows high levels of both to be achieved over a range of activation conditions. This range changes with both SEE compliance and the amplitude of the cyclical length change. The results suggest that a compliant SEE allows a muscle to function closer to the maximum of both power output and efficiency. In addition, by varying the amplitude of the activation level, the efficiency can theoretically remain unchanged, whilst the power output can be modulated.
Collapse
|
|
20 |
52 |
10
|
Herbert RD, Héroux ME, Diong J, Bilston LE, Gandevia SC, Lichtwark GA. Changes in the length and three-dimensional orientation of muscle fascicles and aponeuroses with passive length changes in human gastrocnemius muscles. J Physiol 2014; 593:441-55. [PMID: 25630264 DOI: 10.1113/jphysiol.2014.279166] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2014] [Accepted: 10/23/2014] [Indexed: 01/12/2023] Open
Abstract
The mechanisms by which skeletal muscles lengthen and shorten are potentially complex. When the relaxed human gastrocnemius muscle is at its shortest in vivo lengths it falls slack (i.e. it does not exert any passive tension). It has been hypothesised that when the muscle is passively lengthened, slack is progressively taken up, first in some muscle fascicles then in others. Two-dimensional imaging methods suggest that, once the slack is taken up, changes in muscle length are mediated primarily by changes in the lengths of the tendinous components of the muscle. The aims of this study were to test the hypothesis that there is progressive engagement of relaxed muscle fascicles, and to quantify changes in the length and three-dimensional orientation of muscle fascicles and tendinous structures during passive changes in muscle length. Ultrasound imaging was used to determine the location, in an ultrasound image plane, of the proximal and distal ends of muscle fascicles at 14 sites in the human gastrocnemius muscle as the ankle was rotated passively through its full range. A three-dimensional motion analysis system recorded the location and orientation of the ultrasound image plane and the leg. These data were used to generate dynamic three-dimensional reconstructions of the architecture of the muscle fascicles and aponeuroses. There was considerable variability in the measured muscle lengths at which the slack was taken up in individual muscle fascicles. However, that variability was not much greater than the error associated with the measurement procedure. An analysis of these data which took into account the possible correlations between errors showed that, contrary to our earlier hypothesis, muscle fascicles are not progressively engaged during passive lengthening of the human gastrocnemius. Instead, the slack is taken up nearly simultaneously in all muscle fascicles. Once the muscle is lengthened sufficiently to take up the slack, about half of the subsequent increase in muscle length is due to elongation of the tendinous structures and half is due to elongation of muscle fascicles, at least over the range of muscle-tendon lengths that was investigated (up to ∼60 or 70% of the range of in vivo lengths). Changes in the alignment of muscle fascicles and flattening of aponeuroses contribute little to the total change in muscle length.
Collapse
|
Research Support, Non-U.S. Gov't |
11 |
48 |
11
|
Finni T, Cronin NJ, Mayfield D, Lichtwark GA, Cresswell AG. Effects of muscle activation on shear between human soleus and gastrocnemius muscles. Scand J Med Sci Sports 2015; 27:26-34. [PMID: 26643762 DOI: 10.1111/sms.12615] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/09/2015] [Indexed: 11/30/2022]
Abstract
Lateral connections between muscles provide pathways for myofascial force transmission. To elucidate whether these pathways have functional roles in vivo, we examined whether activation could alter the shear between the soleus (SOL) and lateral gastrocnemius (LG) muscles. We hypothesized that selective activation of LG would decrease the stretch-induced shear between LG and SOL. Eleven volunteers underwent a series of knee joint manipulations where plantar flexion force, LG, and SOL muscle fascicle lengths and relative displacement of aponeuroses between the muscles were obtained. Data during a passive full range of motion were recorded, followed by 20° knee extension stretches in both passive conditions and with selective electrical stimulation of LG. During active stretch, plantar flexion force was 22% greater (P < 0.05) and relative displacement of aponeuroses was smaller than during passive stretch (P < 0.05). Soleus fascicle length changes did not differ between passive and active stretches but LG fascicles stretched less in the active than passive condition when the stretch began at angles of 70° and 90° of knee flexion (P < 0.05). The activity-induced decrease in the relative displacement of SOL and LG suggests stronger (stiffer) connectivity between the two muscles, at least at flexed knee joint angles, which may serve to facilitate myofascial force transmission.
Collapse
|
Journal Article |
10 |
35 |
12
|
Lai AKM, Lichtwark GA, Schache AG, Pandy MG. Differences in in vivo muscle fascicle and tendinous tissue behavior between the ankle plantarflexors during running. Scand J Med Sci Sports 2018; 28:1828-1836. [DOI: 10.1111/sms.13089] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/15/2018] [Indexed: 01/09/2023]
|
|
7 |
34 |
13
|
Barclay CJ, Lichtwark GA, Curtin NA. The energetic cost of activation in mouse fast-twitch muscle is the same whether measured using reduced filament overlap or N-benzyl-p-toluenesulphonamide. Acta Physiol (Oxf) 2008; 193:381-91. [PMID: 18373742 DOI: 10.1111/j.1748-1716.2008.01855.x] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
AIM Force generation and transmembrane ion pumping account for the majority of energy expended by contracting skeletal muscles. Energy turnover for ion pumping, activation energy turnover (E(A)), can be determined by measuring the energy turnover when force generation has been inhibited. Most measurements show that activation accounts for 25-40% of isometric energy turnover. It was recently reported that when force generation in mouse fast-twitch muscle was inhibited using N-benzyl-p-toluenesulphonamide (BTS), activation accounted for as much as 80% of total energy turnover during submaximal contractions. The purpose of this study was to compare E(A) measured by inhibiting force generation by: (1) the conventional method of reducing contractile filament overlap; and (2) pharmacological inhibition using BTS. METHODS Experiments were performed in vitro using bundles of fibres from mouse fast-twitch extensor digitorum longus (EDL) muscle. Energy turnover was quantified by measuring the heat produced during 1-s maximal and submaximal tetanic contractions at 20 and 30 degrees C. RESULTS E(A) measured using reduced filament overlap was 0.36 +/- 0.04 (n = 8) at 20 degrees C and 0.31 +/- 0.05 (n = 6) at 30 degrees C. The corresponding values measured using BTS in maximal contractions were 0.46 +/- 0.06 and 0.38 +/- 0.06 (n = 6 in both cases). There were no significant differences among these values. E(A) was also no different when measured using BTS in submaximal contractions. CONCLUSION Activation energy turnover is the same whether measured using BTS or reduced filament overlap and accounts for slightly more than one-third of isometric energy turnover in mouse EDL muscle.
Collapse
|
|
17 |
29 |
14
|
Hoffman BW, Cresswell AG, Carroll TJ, Lichtwark GA. Muscle fascicle strains in human gastrocnemius during backward downhill walking. J Appl Physiol (1985) 2014; 116:1455-62. [DOI: 10.1152/japplphysiol.01431.2012] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Extensive muscle damage can be induced in isolated muscle preparations by performing a small number of stretches during muscle activation. While typically these fiber strains are large and occur over long lengths, the extent of exercise-induced muscle damage (EIMD) observed in humans is normally less even when multiple high-force lengthening actions are performed. This apparent discrepancy may be due to differences in muscle fiber and tendon dynamics in vivo; however, muscle and tendon strains have not been quantified during muscle-damaging exercise in humans. Ultrasound and an infrared motion analysis system were used to measure medial gastrocnemius fascicle length and lower limb kinematics while humans walked backward, downhill for 1 h (inducing muscle damage), and while they walked briefly forward on the flat (inducing no damage). Supramaximal tibial nerve stimulation, ultrasound, and an isokinetic dynamometer were used to quantify the fascicle length-torque relationship pre- and 2 h postexercise. Torque decreased ∼23%, and optimal fascicle length shifted rightward ∼10%, indicating that EIMD occurred during the damage protocol even though medial gastrocnemius fascicle stretch amplitude was relatively small (∼18% of optimal fascicle length) and occurred predominantly within the ascending limb and plateau region of the length-torque curve. Furthermore, tendon contribution to overall muscle-tendon unit stretch was ∼91%. The data suggest the compliant tendon plays a role in attenuating muscle fascicle strain during backward walking in humans, thus minimizing the extent of EIMD. As such, in situ or in vitro mechanisms of muscle damage may not be applicable to EIMD of the human gastrocnemius muscle.
Collapse
|
|
11 |
25 |
15
|
Farris DJ, Lichtwark GA, Brown NAT, Cresswell AG. Deconstructing the power resistance relationship for squats: A joint-level analysis. Scand J Med Sci Sports 2015; 26:774-81. [PMID: 26103786 DOI: 10.1111/sms.12508] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/18/2015] [Indexed: 11/27/2022]
Abstract
Generating high leg power outputs is important for executing rapid movements. Squats are commonly used to increase leg strength and power. Therefore, it is useful to understand factors affecting power output in squatting. We aimed to deconstruct the mechanisms behind why power is maximized at certain resistances in squatting. Ten male rowers (age = 20 ± 2.2 years; height = 1.82 ± 0.03 m; mass = 86 ± 11 kg) performed maximal power squats with resistances ranging from body weight to 80% of their one repetition maximum (1RM). Three-dimensional kinematics was combined with ground reaction force (GRF) data in an inverse dynamics analysis to calculate leg joint moments and powers. System center of mass (COM) velocity and power were computed from GRF data. COM power was maximized across a range of resistances from 40% to 60% 1RM. This range was identified because a trade-off in hip and knee joint powers existed across this range, with maximal knee joint power occurring at 40% 1RM and maximal hip joint power at 60% 1RM. A non-linear system force-velocity relationship was observed that dictated large reductions in COM power below 20% 1RM and above 60% 1RM. These reductions were due to constraints on the control of the movement.
Collapse
|
Journal Article |
10 |
23 |
16
|
Hoffman BW, Lichtwark GA, Carroll TJ, Cresswell AG. A comparison of two Hill-type skeletal muscle models on the construction of medial gastrocnemius length-tension curves in humans in vivo. J Appl Physiol (1985) 2012; 113:90-6. [DOI: 10.1152/japplphysiol.00070.2012] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Human length-tension curves are traditionally constructed using a model that assumes passive tension does not change during contraction ( model A) even though the animal literature suggests that passive tension can decrease ( model B). The study's aims were threefold: 1) measure differences in human medial gastrocnemius length-tension curves using model A vs. model B, 2) test the reliability of ultrasound constructed length-tension curves, and 3) test the robustness of fascicle length-generated length-tension curves to variations between the angle and fascicle length relationship. An isokinetic dynamometer manipulated and measured ankle angle while ultrasound was used to measure medial gastrocnemius fascicle length. Supramaximal tibial nerve stimulation was used to evoke resting muscle twitches. Length-tension curves were constructed using model A {angle-torque [A-T(A)], length-torque [L-T(A)]} or model B {length-torque [L-T(B)]} in three conditions: baseline, heel-lift (where the muscle was shortened at each angle), and baseline repeated 2 h later (+2 h). Length-tension curves constructed from model B differed from those produced via model A, indicated by a significant increase in maximum torque (≈23%) when using L-T(B) vs. L-T(A). No parameter measured was different between baseline and +2 h for any method, indicating good reliability when using ultrasound. Length-tension curves were unaffected by the heel-lift condition when using L-T(A) or L-T(B) but were affected when using A-T(A). Since the muscle model used significantly alters human length-tension curves, and given animal data indicate model B to be more accurate when passive tension is present, we recommend that model B should be used when constructing medial gastrocnemius length-tension curves in humans in vivo.
Collapse
|
|
13 |
22 |
17
|
Barclay CJ, Lichtwark GA. The mechanics of mouse skeletal muscle when shortening during relaxation. J Biomech 2007; 40:3121-9. [PMID: 17499255 DOI: 10.1016/j.jbiomech.2007.03.024] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2006] [Revised: 03/21/2007] [Accepted: 03/22/2007] [Indexed: 11/20/2022]
Abstract
The dynamic properties of relaxing skeletal muscle have not been well characterised but are important for understanding muscle function during terrestrial locomotion, during which a considerable fraction of muscle work output can be produced during relaxation. The purpose of this study was to characterise the force-velocity properties of mouse skeletal muscle during relaxation. Experiments were performed in vitro (21 degrees C) using bundles of fibres from mouse soleus and EDL muscles. Isovelocity shortening was applied to muscles during relaxation following short tetanic contractions. Using data from different contractions with different shortening velocities, curves relating force output to shortening velocity were constructed at intervals during relaxation. The velocity component included contributions from shortening of both series elastic component (SEC) and contractile component (CC) because force output was not constant. Early in relaxation force-velocity relationships were linear but became progressively more curved as relaxation progressed. Force-velocity curves late in relaxation had the same curvature as those for the CC in fully activated muscles but V(max) was reduced to approximately 50% of the value in fully activated muscles. These results were the same for slow- and fast-twitch muscles and for relaxation following maximal tetani and brief, sub-maximal tetani. The measured series elastic compliance was used to partition shortening velocity between SEC and CC. The curvature of the CC force-velocity relationship was constant during relaxation. The SEC accounted for most of the shortening and work output during relaxation and its power output during relaxation exceeded the maximum CC power output. It is proposed that unloading the CC, without any change in its overall length, accelerated cross-bridge detachment when shortening was applied during relaxation.
Collapse
|
|
18 |
14 |
18
|
Lichtwark GA, Barclay CJ. A compliant tendon increases fatigue resistance and net efficiency during fatiguing cyclic contractions of mouse soleus muscle. Acta Physiol (Oxf) 2012; 204:533-43. [PMID: 21910835 DOI: 10.1111/j.1748-1716.2011.02361.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
AIM As muscles fatigue, their ability to generate mechanical work decreases as a result of decreased force generation and in cyclic activity, slower the relaxation. The purpose of this study was to determine whether a compliant tendon, connected in series with a muscle, would increase sustained work output during cyclic contractions. METHODS Experiments were performed in vitro (37 °C) using fibre bundles from mouse soleus muscles (n = 7). Each muscle performed two series of 40 brief contractions at a contraction frequency of 2 Hz and with a sinusoidal length change. One series was performed using the fibre bundle only and one with the fibre bundle and a compliant strip of latex connected between the muscle and the force recording apparatus. RESULTS When contracting with the latex strip, muscle work output was better maintained during the second half of the protocol than when performed without the latex, overall energy cost was reduced and mechanical efficiency was increased. CONCLUSION The provision of a compliant tendon analogue increased the level of work output that could be sustained during cyclic contractions and reduced energy expenditure. It is proposed that both metabolic and mechanical consequences of the compliant tendon contribute to the improved performance.
Collapse
|
|
13 |
14 |
19
|
Pincheira PA, Hoffman BW, Cresswell AG, Carroll TJ, Brown NAT, Lichtwark GA. The repeated bout effect can occur without mechanical and neuromuscular changes after a bout of eccentric exercise. Scand J Med Sci Sports 2018; 28:2123-2134. [PMID: 29790207 DOI: 10.1111/sms.13222] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/16/2018] [Indexed: 11/29/2022]
Abstract
Changes in muscle fascicle mechanics have been postulated to underpin the repeated bout effect (RBE) observed following exercise-induced muscle damage (EIMD). However, in the medial gastrocnemius (MG), mixed evidence exists on whether fascicle stretch amplitude influences the level of EIMD, thus questioning whether changes in fascicle mechanics underpin the RBE. An alternative hypothesis is that neural adaptations contribute to the RBE in this muscle. The aim of this study was to investigate the neuromechanical adaptations during and after repeated bouts of a highly controlled muscle lengthening exercise that aimed to maximize EIMD in MG. In all, 20 subjects performed two bouts of 500 active lengthening contractions (70% of maximal activation) of the triceps surae, separated by 7 days. Ultrasound constructed fascicle length-torque (L-T) curves of MG, surface electromyography (EMG), maximum torque production, and muscle soreness were assessed before, 2 hours and 2 days after each exercise bout. The drop in maximum torque (4%) and the increase in muscle soreness (24%) following the repeated bout were significantly less than following the initial bout (8% and 59%, respectively), indicating a RBE. However, neither shift in the L-T curve nor changes in EMG parameters were present. Furthermore, muscle properties during the exercise were not related to the EIMD or RBE. Our results show that there are no global changes in gastrocnemius mechanical behavior or neural activation that could explain the observed RBE in this muscle. We suggest that adaptations in the non-contractile elements of the muscle are likely to explain the RBE in the triceps surae.
Collapse
|
Journal Article |
7 |
13 |
20
|
Brennan SF, Cresswell AG, Farris DJ, Lichtwark GA. The effect of cadence on the muscle-tendon mechanics of the gastrocnemius muscle during walking. Scand J Med Sci Sports 2016; 27:289-298. [DOI: 10.1111/sms.12656] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/19/2016] [Indexed: 11/29/2022]
|
|
9 |
9 |
21
|
Finni T, Lichtwark GA. Rise of the tendon research. Scand J Med Sci Sports 2016; 26:992-4. [DOI: 10.1111/sms.12731] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/16/2016] [Indexed: 01/06/2023]
|
|
9 |
3 |
22
|
Hutchinson LA, Lichtwark GA, Willy RW, Kelly LA. The Iliotibial Band: A Complex Structure with Versatile Functions. Sports Med 2022; 52:995-1008. [PMID: 35072941 PMCID: PMC9023415 DOI: 10.1007/s40279-021-01634-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/10/2021] [Indexed: 11/20/2022]
Abstract
The development of a pronounced iliotibial band (ITB) is an anatomically distinct evolution of humans. The mechanical behaviour of this “new” structure is still poorly understood and hotly debated in current literature. Iliotibial band syndrome (ITBS) is one of the leading causes of lateral knee pain injuries in runners. We currently lack a comprehensive understanding of the healthy behaviour of the ITB, and this is necessary prior to further investigating the aetiology of pathologies like ITBS. Therefore, the purpose of this narrative review was to collate the anatomical, biomechanical and clinical literature to understand how the mechanical function of the ITB is influenced by anatomical variation, posture and muscle activation. The complexity of understanding the mechanical function of the ITB is due, in part, to the presence of its two in-series muscles: gluteus maximus (GMAX) and tensor fascia latae (TFL). At present, we lack a fundamental understanding of how GMAX and TFL transmit force through the ITB and what mechanical role the ITB plays for movements like walking or running. While there is a range of proposed ITBS treatment strategies, robust evidence for effective treatments is still lacking. Interventions that directly target the running biomechanics suspected to increase either ITB strain or compression of lateral knee structures may have promise, but clinical randomised controlled trials are still required.
Collapse
|
Review |
3 |
|
23
|
Rees JD, Lichtwark GA, Wolman RL, Wilson AM. Comment on: The mechanism for efficacy of eccentric loading in Achilles tendon injury; an in vivo study in humans: reply. Rheumatology (Oxford) 2008. [DOI: 10.1093/rheumatology/ken423] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
|
17 |
|
24
|
Aeles J, Bellett M, Lichtwark GA, Cresswell AG. The effect of small changes in rate of force development on muscle fascicle velocity and motor unit discharge behaviour. Eur J Appl Physiol 2022; 122:1035-1044. [PMID: 35146568 PMCID: PMC8926959 DOI: 10.1007/s00421-022-04905-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Accepted: 01/28/2022] [Indexed: 11/14/2022]
Abstract
When rate of force development is increased, neural drive increases. There is presently no accepted explanation for this effect. We propose and experimentally test the theory that a small increase in rate of force development increases medial gastrocnemius fascicle shortening velocity, reducing the muscle's force-generating capacity, leading to active motor units being recruited at lower forces and with increased discharge frequencies. Participants produced plantar flexion torques at three different rates of force development (slow: 2% MVC/s, medium: 10% MVC/s, fast: 20% MVC/s). Ultrasound imaging showed that increased rate of force development was related to higher fascicle shortening velocity (0.4 ± 0.2 mm/s, 2.0 ± 0.9 mm/s, 4.1 ± 1.9 mm/s in slow, medium, fast, respectively). In separate experiments, medial gastrocnemius motor unit recruitment thresholds and discharge frequencies were measured using fine-wire electromyography (EMG), together with surface EMG. Recruitment thresholds were lower in the fast (12.8 ± 9.2% MVC) and medium (14.5 ± 9.9% MVC) conditions compared to the slow (18.2 ± 8.9% MVC) condition. The initial discharge frequency was lower in the slow (5.8 ± 3.1 Hz) than the fast (6.7 ± 1.4 Hz), but not than the medium (6.4 ± 2.4 Hz) condition. The surface EMG was greater in the fast (mean RMS: 0.029 ± 0.017 mV) compared to the slow condition (0.019 ± 0.013 mV). We propose that the increase in muscle fascicle shortening velocity reduces the force-generating capacity of the muscle, therefore requiring greater neural drive to generate the same forces.
Collapse
|
research-article |
3 |
|