1
|
Finite element analysis of the interaction between high-compliant balloon catheters and non-cylindrical vessel structures: towards tactile sensing balloon catheters. Biomech Model Mechanobiol 2023; 22:2033-2061. [PMID: 37573552 PMCID: PMC10613175 DOI: 10.1007/s10237-023-01749-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Accepted: 07/06/2023] [Indexed: 08/15/2023]
Abstract
Aiming for sensing balloon catheters which are able to provide intraoperative information of the vessel stiffness and shape, the present study uses finite element analysis (FEA) to evaluate the interaction between high-compliant elastomer balloon catheters with the inner wall of a non-cylindrical-shaped lumen structure. The contact simulations are based on 3D models with varying balloon thicknesses and varying tissue geometries to analyse the resulting balloon and tissue deformation as well as the inflation pressure dependent contact area. The wrinkled tissue structure is modelled by utilizing a two-layer fibre-based Holzapfel-Gasser-Ogden constitutive model and the model parameters are adapted based on available biomechanical data for human urethral vessel samples. The balloon catheter structure is implemented as a high-compliant hyper-elastic silicone material (based on polydimethylsiloxane (PDMS)) with a varying catheter wall thickness between 0.5 and 2.5 µm. Two control parameters are introduced to describe the balloon shape adaption in reaction to a wrinkled vessel wall during the inflation process. Basic semi-quantitative relations are revealed depending on the evolving balloon deformation and contact surface. Based on these relations some general design guidelines for balloon-based sensor catheters are presented. The results of the conducted in-silico study reveal some general interdependencies with respect to the compliance ratio between balloon and tissue and also in respect of the tissue aspect ratio. Further they support the proposed concept of high-compliant balloon catheters equipped for tactile sensing as diagnosis approach in urology and angioplasty.
Collapse
|
2
|
Advanced electrochemical potential monitoring for improved understanding of electrical neurostimulation protocols. J Neural Eng 2023. [PMID: 37307808 DOI: 10.1088/1741-2552/acdd9d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
OBJECTIVE 
Current-controlled neurostimulation is increasingly used in the clinical treatment of neurological disorders and widely applied in neural prostheses such as cochlear implants. Despite its importance, time-dependent potential traces of electrodes during microsecond-scale current pulses, especially with respect to an electrochemical reference scale, are not precisely understood. However, this knowledge is critical to predict contributions of chemical reactions at the electrodes, and ultimately electrode stability, biocompatibility, and stimulation safety and efficacy.
Approach.
We assessed the electrochemistry of neurostimulation protocols with Pt microelectrodes from millisecond (classical electroanalysis) to microsecond (neurostimulation) timescales. We developed a dual-channel instrumentation amplifier to include a reference electrode in neurostimulation setups. Uniquely, we combined potential measurements with potentiostatic prepolarization to control and investigate the surface status, which is not possible in typical stimulation setups.
Main results.
We thoroughly validated the instrumentation and highlighted the importance of monitoring individual electrochemical electrode potentials in different configurations of neurostimulation. We investigated electrode processes such as oxide formation and oxygen reduction by chronopotentiometry, bridging the gap between milli- and microsecond timescales. Our results demonstrate how much impact on potential traces the electrode's initial surface state and electrochemical surface processes have, even on a microsecond scale.
Significance.
Our unique use of preconditioning in combination with stimulation reveals that interpreting potential traces with respect to electrode processes is misleading without rigorous control of the electrode's surface state. Especially in vivo, where the microenvironment is unknown, simply measuring the voltage between two electrodes cannot accurately reflect the electrode's state and processes. Potential boundaries determine charge transfer, corrosion, and alterations of the electrode/tissue interface such as pH and oxygenation, particularly in long-term in vivo use. Our findings are relevant for all use-cases of constant-current stimulation, strongly advocating for electrochemical in situ investigations in many applications like the development of new electrode materials and stimulation methods.
.
Collapse
|
3
|
Electrochemical microelectrode degradation monitoring: in situ investigation of platinum corrosion at neutral pH. J Neural Eng 2022; 19. [PMID: 34983028 DOI: 10.1088/1741-2552/ac47da] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Accepted: 01/04/2022] [Indexed: 11/11/2022]
Abstract
OBJECTIVE The stability of platinum and other noble metal electrodes is critical for neural implants, electrochemical sensors, and energy sources. Beyond the acidic or alkaline environment found in most electrochemical studies, the investigation of electrode corrosion in neutral pH and chloride containing electrolytes is essential, particularly regarding the long-term stability of neural interfaces, such as brain stimulation electrodes or cochlear implants. In addition, the increased use of microfabricated devices demands the investigation of thin-film electrode stability. APPROACH We developed a procedure of electrochemical methods for continuous tracking of electrode degradation in situ over the complete life cycle of platinum thin-film microelectrodes in a unique combination with simultaneous chemical sensing. We used chronoamperometry and cyclic voltammetry to measure electrode surface and analyte redox processes, together with accelerated electrochemical degradation. MAIN RESULTS We compared degradation between thin-film microelectrodes and bulk electrodes, neutral to acidic pH, different pulsing schemes, and the presence of the redox active species oxygen and hydrogen peroxide. Results were confirmed by mechanical profilometry and microscopy to determine material changes on a nanometer scale. We found that electrode degradation is mainly driven by repeated formation and removal of the platinum surface oxide, also within the electrochemical stability window of water. There was no considerable difference between thin-film micro- and macroscopic bulk electrodes or in the presence of reactive species, whereas acidic pH or extending the potential window led to increased degradation. SIGNIFICANCE Our results provide valuable fundamental information on platinum microelectrode degradation under conditions found in biomedical applications. For the first time, we deployed a unified method to report quantitative data on electrode degradation up to a defined endpoint. Our method is a widely applicable framework for comparative long-term studies of sensor and neural interface stability.
Collapse
|
4
|
Electromagnetic stimulation of the phrenic nerve preserves diaphragm muscle strength during mechanical ventilation in a rat model. Eur J Anaesthesiol 2022; 39:81-82. [PMID: 34857687 DOI: 10.1097/eja.0000000000001590] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
5
|
Ion Mobility in Thick and Thin Poly-3,4 Ethylenedioxythiophene Films-From EQCM to Actuation. Polymers (Basel) 2021; 13:polym13152448. [PMID: 34372051 PMCID: PMC8348298 DOI: 10.3390/polym13152448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2021] [Revised: 07/10/2021] [Accepted: 07/14/2021] [Indexed: 11/16/2022] Open
Abstract
Conductive polymer actuators and sensors rely on controlled ion transport coupled to a potential/charge change. In order to understand and control such devices, it is of paramount importance to understand the factors that determine ion flux at various conditions, including the synthesis potential. In this work, the ion transport in thinner poly-3,4-ethylenedioxythiophene (PEDOT) films during charge/discharge driven by cyclic voltammetry is studied by consideration of the electrochemical quartz crystal microbalance (EQCM) and the results are compared to the actuation responses of thicker films that have been synthesized with the same conditions in the bending and linear expansion modes. The effects of polymerization potentials of 1.0 V, 1.2 V, and 1.5 V are studied to elucidate how polymerization potential contributes to actuation, as well the involvement of the EQCM. In this work, it is revealed that there is a shift from anion-dominated to mixed to cation-dominated activity with increased synthesis potential. Scanning electron microscopy shows a decrease in porosity for the PEDOT structure with increasing synthesis potential. EQCM analysis of processes taking place at various potentials allows the determination of appropriate potential windows for increased control over devices.
Collapse
|
6
|
Long-term in vivomonitoring of gliotic sheathing of ultrathin entropic coated brain microprobes with fiber-based optical coherence tomography. J Neural Eng 2021; 18. [PMID: 33657543 DOI: 10.1088/1741-2552/abebc2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Accepted: 03/03/2021] [Indexed: 11/11/2022]
Abstract
Objective.Microfabricated neuroprosthetic devices have made possible important observations on neuron activity; however, long-term high-fidelity recording performance of these devices has yet to be realized. Tissue-device interactions appear to be a primary source of lost recording performance. The current state of the art for visualizing the tissue response surrounding brain implants in animals is immunohistochemistry + confocal microscopy, which is mainly performed after sacrificing the animal. Monitoring the tissue response as it develops could reveal important features of the response which may inform improvements in electrode design.Approach.Optical coherence tomography (OCT), an imaging technique commonly used in ophthalmology, has already been adapted for imaging of brain tissue. Here, we use OCT to achieve real-time,in vivomonitoring of the tissue response surrounding chronically implanted neural devices. The employed tissue-response-provoking implants are coated with a plasma-deposited nanofilm, which has been demonstrated as a biocompatible and anti-inflammatory interface for indwelling devices. We evaluate the method by comparing the OCT results to traditional histology qualitatively and quantitatively.Main results.The differences in OCT signal across the implantation period between the plasma group and the control reveal that the plasma-type coating of otherwise rigid brain probes (glass) only slightly improve the glial encapsulation in the brain parenchyma indicating that geometrical or mechanical influences are dominating the encapsulation process.Significance.Our approach can long-term monitor and compare the tissue-response to chronically-implanted neural probes with and withour plasma coating in living animal models. Our findings provide valuable insigh to the well acknowledged yet not solved challenge.
Collapse
|
7
|
Efficacy of Retreatment After Failed Direct-acting Antiviral Therapy in Patients With HCV Genotype 1-3 Infections. Clin Gastroenterol Hepatol 2021; 19:195-198.e2. [PMID: 31706062 DOI: 10.1016/j.cgh.2019.10.051] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Revised: 09/19/2019] [Accepted: 10/25/2019] [Indexed: 02/07/2023]
Abstract
Hepatitis C virus infection is causing chronic liver disease, cirrhosis, and hepatocellular carcinoma. By combining direct-acting antivirals (DAAs), high sustained virologic response rates (SVRs) can be achieved. Resistance-associated substitutions (RASs) are commonly observed after DAA failure, and especially nonstructural protein 5A (NS5A) RASs may impact retreatment options.1-3 Data on retreatment of DAA failure patients using first-generation DAAs are limited.4-7 Recently, a second-generation protease- and NS5A-inhibitor plus sofosbuvir (voxilaprevir/velpatasvir/sofosbuvir [VOX/VEL/SOF]) was approved for retreatment after DAA failure.8 However, this and other second-generation regimens are not available in many resource-limited countries or are not reimbursed by regular insurance, and recommendations regarding the selection of retreatment regimens using first-generation DAAs are very important. This study aimed to analyze patients who were re-treated with first-generation DAAs after failure of a DAA combination therapy.
Collapse
|
8
|
Mechanical ventilation restores blood gas homeostasis and diaphragm muscle strength in ketamine/medetomidine-anaesthetized rats. Exp Physiol 2020; 106:396-400. [PMID: 33200855 DOI: 10.1113/ep089141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2020] [Accepted: 11/11/2020] [Indexed: 11/08/2022]
Abstract
NEW FINDINGS What is the central question of the study? Does respiratory support ensure blood gas homeostasis and the relevance of experimental outcomes? What is the main finding and its importance? Spontaneous breathing during surgical intervention under anaesthesia results in impaired gas exchange and loss of diaphragm muscle strength in rats. Subsequent short-term mechanical ventilation restored blood gas homeostasis and diaphragm muscle strength. Blood gas homeostasis interferes substantially with experimental conditions and may alter study results. Monitoring and maintenance of blood gas balance is required to ensure quality and relevance of physiological animal experiments. ABSTRACT In pre-clinical small animal studies with surgical interventions under general anaesthesia, animals are often left to breathe spontaneously. However, anaesthesia may impair respiratory functions and result in disturbed blood gas homeostasis. In turn, the disturbed blood gas homeostasis can affect physiological functions and thus unintentionally impact the experimental results. We hypothesized that short-term mechanical ventilation restores blood gas balance and physiological functions despite anaesthesia and surgical interventions. Therefore, we investigated variables of blood gas analyses and diaphragm muscle strength in rats anaesthetized with ketamine/medetomidine after tracheotomy and catheterization of the carotid artery under spontaneous breathing and after 20 min of mechanical ventilation following the same surgical intervention. Spontaneous breathing during general anaesthesia and surgical intervention resulted in unphysiological blood oxygen partial pressure (<65 mmHg) and carbon dioxide partial pressure (>55 mmHg). After subsequent short-term mechanical ventilation, blood gas partial pressures were restored to their physiological ranges. Additionally, diaphragm muscle strength of animals breathing spontaneously was lower compared to animals that received subsequent mechanical ventilation (P = 0.0063). We conclude that spontaneous breathing of rats under ketamine/medetomidine anaesthesia is not sufficient to maintain a physiological blood gas balance. Disturbed blood gas balance is related to reduced diaphragm muscle strength. Mechanical ventilation for only 20 min restores blood gas homeostasis and muscle strength. Therefore, monitoring and maintenance of blood gas balance should be conducted to ensure quality and relevance of small animal experiments.
Collapse
|
9
|
A linearized expiration flow homogenizes the compartmental pressure distribution in a physical model of the inhomogeneous respiratory system. Physiol Meas 2020; 41:045005. [DOI: 10.1088/1361-6579/ab83e6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
10
|
Direct EPR detection of atomic nitrogen in an atmospheric nitrogen plasma jet. Phys Chem Chem Phys 2020; 22:3875-3882. [PMID: 32043098 DOI: 10.1039/c9cp05799d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
In this study, an atmospheric nitrogen plasma jet generated by a custom-built micro-plasma device was analyzed at room temperature by continuous wave and pulse EPR spectroscopy in real time. Transiently formed nitrogen atoms were detected without the necessity to use spin-traps or other reagents for their stabilization. In contrast to results from optical emission spectroscopy, only signals from the 4S ground state of 14N and 15N could be detected. EPR data analysis revealed an isotropic g value of 1.9971 and isotropic hyperfine coupling constants of a(14N) = (10.47 ± 0.02) MHz and a(15N) = (14.69 ± 0.02) MHz. Moreover, lifetime and relaxation data could be determined; both are discussed in terms of spectral widths and actual concentrations of the transiently formed nitrogen species within the plasma jet. The data show that the lifetimes of atomic nitrogen and charged particles such as N+ must be different, and for the latter below the observation time window of EPR spectroscopy. We demonstrate that the real-time (pulsed) EPR technique is a fast and reliable alternative to detect atomic nitrogen in atmospheric pressure plasma jets. The method may be used for a continuous monitoring of the quality of plasma jets.
Collapse
|
11
|
Multichannel Cell Detection in Microcompartments by Means of True Parallel Measurements using the Solartron S-1260. JOURNAL OF ELECTRICAL BIOIMPEDANCE 2020; 11:49-56. [PMID: 33584903 PMCID: PMC7531105 DOI: 10.2478/joeb-2020-0008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Indexed: 05/27/2023]
Abstract
Designing proper frontend electronics is critical in the development of highly sophisticated electrode systems. Multielectrode arrays for measuring electrical signals or impedance require multichannel readout systems. Even more challenging is the differential or ratiometric configuration with simultaneous assessment of measurement and reference channels. In this work, an eight-channel frontend was developed for contacting a 2×8 electrode array (8 measurement and 8 reference electrodes) with a large common electrode to the impedance gain-phase analyzer Solartron 1260 (S-1260). Using the three independent and truly parallel monitor channels of the S-1260, impedance of trapped cells and reference material was measured at the same time, thereby considerably increasing the performance of the device. The frontend electronics buffers the generator output and applies a potentiostatic signal to the common electrode of the chip. The applied voltage is monitored using the current monitor of the S-1260 via voltage/current conversion. The frontend monitors the current through the electrodes and converts it to a voltage fed into the voltage monitors of the S-1260. For assessment of the 8 electrode pairs featured by the chip, a relay-based multiplexer was implemented. Extensive characterization and calibration of the frontend were carried out in a frequency range between 100 Hz and 1 MHz. Investigating the influence of the multiplexer and the frontend electronics, direct measurement with and without frontend was compared. Although differences were evident, they have been negligible below one per cent. The significance of measurement using the complex S-1260-frontend-electrode was tested using Kohlrausch's law. The impedance of an electrolytic dilution series was measured and compared to the theoretical values. The coincidence of measured values and theoretical prediction serves as an indicator for electrode sensitivity to cell behavior. Monitoring of cell behavior on the microelectrode surface will be shown as an example.
Collapse
|
12
|
Electrochemical Stability of Thin-Film Platinum as Suitable Material for Neural Stimulation Electrodes. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2019; 2019:3762-3765. [PMID: 31946693 DOI: 10.1109/embc.2019.8856621] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Only thin-film technology can satisfy the requirements of high spatial selectivity at high-channel-count electrode array designs by simultaneously good conformability to the targeted tissue through mechanical flexibility enriching future applications of functional neural stimulation. However, caused by the high impact of the microstructure on the mechanical and electrochemical film properties, varying fabrication processes of the same thin-film makes the difference between acute and chronic long-term stable electrodes. The influence of standard clinical electrical pulsing on flexible polyimide-based thin-film platinum electrodes for neuroprostheses, either sputter deposited or evaporated, and different diameters was assessed and compared. The electrochemical and morphological analysis showed a higher corrosion susceptibility and electrochemical degradation for the sputter deposited platinum electrodes with even total failures of smaller diameters. In contrast, the evaporated thin-films provided itself as more stable and reliable metallization with also smaller electrodes keeping their film integrity intact over the experimental period, -appearing to be the preferable material for improving thin-film electrodes' longevity.
Collapse
|
13
|
|
14
|
Abstract
Abstract
The most common complication after implantation of foreign material is infection, leading to implant failure and severe patient discomfort. Smoldering-infections proceed inapparently and might not get verified by radiological diagnostics. Early identification of this type of infection might significantly reduce the rate of complications. Therefore, we manufactured a microsensor strip in a hybrid of thin-film and laminate technology in a wafer-level process. It comprises electrochemical, amperometric microsensors for glucose, oxygen and lactate as well as an integrated reference electrode. Microsensors have been implanted in the mouse dorsal skin fold chamber, which got inoculated with a human-pathogen bacterial strain. A selective signal could be measured for all parameters and time points. The infection led to measurable changes of the wound environment as given by a decrease of the oxygen- as well as the glucose-concentration while the lactate concentration increased markedly over time. The given results in this study are the first hints on a promising new tool and should therefore be interpreted as a proof of the principle to show the functionality of the microsensors in an in vivo setting. These microsensors could be used to monitor smoldering infections of implantable foreign materials reducing foreign implant associated complications.
Collapse
|
15
|
|
16
|
High electrocatalytic activity of metal-free and non-doped hierarchical carbon nanowalls towards oxygen reduction reaction. Electrochim Acta 2018. [DOI: 10.1016/j.electacta.2018.03.054] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
17
|
Interstitial Glucose and Lactate Levels Are Inversely Correlated With the Body Mass Index: Need for In Vivo Calibration of Glucose Sensor Results With Blood Values in Obese Patients. J Diabetes Sci Technol 2018; 12:341-348. [PMID: 28931321 PMCID: PMC5851218 DOI: 10.1177/1932296817730377] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
BACKGROUND Continuously measured glucose and lactate levels in interstitial fluid (ISF) may markedly differ from their respective blood levels. METHODS Combining microdialysis with a bioanalytical microsystem, the interstitial glucose and lactate concentrations of eight male volunteers with different body mass index (BMI) were monitored during a 2-fold glucose tolerance test over the period of three hours. RESULTS Significant correlations were found between abdominally measured sensor results and reference measurements ( R2 = .967 for glucose and R2 = .936 for lactate, P < .05). The physiological delay of the abdominally observed glucose appearance in the ISF correlated positively with the BMI ( R2 = .787, P < .05). The relative in vivo recovery of glucose and lactate was inversely proportional to the BMI of the volunteers ( R2 = .540 for glucose, R2 = .609 for lactate, P < .05). One subject with a BMI of > 34 kg/m2 showed abdominally as well as the antebrachially significantly reduced tissue glucose values compared to blood glucose values ( P < .001). CONCLUSIONS A very good correlation between abdominally measured sensor results and the results of the reference method verified the reliability of the BioMEMS. The abdominally measured glucose level in ISF decreased significantly with increasing BMI. Therefore, an in vivo calibration of glucose levels in ISF with blood levels seems to be necessary especially in markedly obese subjects.
Collapse
|
18
|
Capacity of rTth polymerase to detect RNA in the presence of various inhibitors. PLoS One 2018; 13:e0190041. [PMID: 29293599 PMCID: PMC5749758 DOI: 10.1371/journal.pone.0190041] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2017] [Accepted: 12/07/2017] [Indexed: 11/19/2022] Open
Abstract
The full potential of the real-time reverse transcription polymerase chain reaction (RT-PCR) as a rapid and accurate diagnostic method is limited by DNA polymerase inhibitors as well as reverse transcriptase inhibitors which are ubiquitous in clinical samples. rTth polymerase has proven to be more resistant to DNA polymerase inhibitors present in clinical samples for DNA detection and also exhibits reverse transcriptase activity in the presence of Mn2+ ions. However, the capacity of rTth polymerase, which acts as DNA polymerase and reverse transcriptase, to detect RNA in the presence of various inhibitors has not been investigated in detail. Herein, the inhibitors originating from various clinical samples such as blood, urine, feces, bodily fluids, tissues and reagents used during nucleic acid extraction were employed to evaluate the capacity of rTth polymerase to detect RNA. The results show that the inhibitors have different inhibitory effects on the real-time RT-PCR reactions by rTth polymerase, and the inhibitory effects are concentration dependent. Additionally, the capacity of rTth polymerase to detect RNA in the presence of various inhibitors is better or at least comparable with its capacity to detect DNA in the presence of various inhibitors. As a consequence, RNA may be directly detected in the presence of co-purified inhibitors or even directly from crude clinical samples by rTth polymerase.
Collapse
|
19
|
Direct enrichment of pathogens from physiological samples of high conductivity and viscosity using H-filter and positive dielectrophoresis. BIOMICROFLUIDICS 2018; 12:014109. [PMID: 29430274 PMCID: PMC5780277 DOI: 10.1063/1.5016413] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2017] [Accepted: 01/09/2018] [Indexed: 06/08/2023]
Abstract
The full potential of microfluidic techniques as rapid and accurate methods for the detection of disease-causing agents and foodborne pathogens is critically limited by the complex sample preparation process, which commonly comprises the enrichment of bacterial cells to detectable levels. In this manuscript, we describe a microfluidic device which integrates H-filter desalination with positive dielectrophoresis (pDEP) for direct enrichment of bacterial cells from physiological samples of high conductivity and viscosity, such as cow's milk and whole human blood. The device contained a winding channel in which electrolytes in the samples continuously diffused into deionized (DI) water (desalination), while the bacterial cells remained in the samples. The length of the main channel was optimized by numerical simulation and experimentally evaluated by the diffusion of fluorescein into DI water. The effects of another three factors on H-filter desalination were also investigated, including (a) the flow rate ratio between the sample and DI water, (b) sample viscosity, and (c) non-Newtonian fluids. After H-filter desalination, the samples were withdrawn into the dielectrophoresis chamber in which the bacterial cells were captured by pDEP. The feasibility of the device was demonstrated by the direct capture of the bacterial cells in 1× PBS buffer, cow's milk, and whole human blood after H-filter desalination, with the capture efficiencies of 70.7%, 90.0%, and 80.2%, respectively. We believe that this simple method can be easily integrated into portable microfluidic diagnosis devices for rapid and accurate detection of disease-causing agents and foodborne pathogens.
Collapse
|
20
|
Clinical on-site monitoring of ß-lactam antibiotics for a personalized antibiotherapy. Sci Rep 2017; 7:3127. [PMID: 28600499 PMCID: PMC5466632 DOI: 10.1038/s41598-017-03338-z] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2017] [Accepted: 04/26/2017] [Indexed: 01/07/2023] Open
Abstract
An appropriate antibiotherapy is crucial for the safety and recovery of patients. Depending on the clinical conditions of patients, the required dose to effectively eradicate an infection may vary. An inadequate dosing not only reduces the efficacy of the antibiotic, but also promotes the emergence of antimicrobial resistances. Therefore, a personalized therapy is of great interest for improved patients' outcome and will reduce in long-term the prevalence of multidrug-resistances. In this context, on-site monitoring of the antibiotic blood concentration is fundamental to facilitate an individual adjustment of the antibiotherapy. Herein, we present a bioinspired approach for the bedside monitoring of free accessible ß-lactam antibiotics, including penicillins (piperacillin) and cephalosporins (cefuroxime and cefazolin) in untreated plasma samples. The introduced system combines a disposable microfluidic chip with a naturally occurring penicillin-binding protein, resulting in a high-performance platform, capable of gauging very low antibiotic concentrations (less than 6 ng ml-1) from only 1 µl of serum. The system's applicability to a personalized antibiotherapy was successfully demonstrated by monitoring the pharmacokinetics of patients, treated with ß-lactam antibiotics, undergoing surgery.
Collapse
|
21
|
Platinum nanowires anchored on graphene-supported platinum nanoparticles as a highly active electrocatalyst towards glucose oxidation for fuel cell applications. NANOSCALE 2017; 9:6436-6447. [PMID: 28463371 DOI: 10.1039/c7nr01391d] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
The limited performance of platinum-based electrocatalysts for glucose electrooxidation is a major concern for glucose fuel cells, since glucose electrooxidation is characterized by slow reaction kinetics and low diffusion coefficient. Here, the presented graphene-supported platinum-based hierarchical nanostructures attain highly enhanced electrocatalytic activity towards glucose oxidation. Platinum nanoparticles electrodeposited on graphene support retain mechanical stability and act as junctions allowing a reliable, smooth and dense growth of platinum nanowires with extremely small diameters (>10 nm) on graphene. The electrode's surface roughness was increased by factors up to 4000 to the geometrical surface area enabling maximized exploitation of the electrocatalytic activity of platinum and efficient electron transfer between nanowires and the substrate. The unique three-dimensional geometry of these hierarchical nanostructures has a significant impact on their catalytic performance offering short diffusional paths for slow glucose species, thus, mass transport limitations are optimized leading to lower polarization losses. This was examined by galvanostatic measurements of the operation as anodes in glucose half-cells under conditions corresponding to implantable glucose fuel cells. The presented hierarchical nanostructures show remarkably enhanced catalytic performance for glucose electrooxidation, i.e. a negatively shifted open circuit potential of -580 mV vs. Ag/AgCl, hence, representing appropriate electrocatalysts for use as anodes in glucose fuel cells. In combination with a non-metal N-doped graphene cathode, a cell potential of 0.65 V was achieved at a galvanostatic load of 17.5 μA cm-2 which noticeably surpasses the performance of state of the art catalysts for the aforementioned operation conditions.
Collapse
|
22
|
Potentiometrische Untersuchungen zur Komplexbildung von Cera, CeIII, ThIV, UIV und Citrat in wäßriger Lösung. Z PHYS CHEM 2017. [DOI: 10.1515/zpch-1966-23310] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
23
|
Rational Design of Morphological Characteristics to Determine the Optimal Hierarchical Nanostructures in Heterogeneous Catalysis. ChemCatChem 2016. [DOI: 10.1002/cctc.201600914] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
24
|
Nanomolar detection of methylparaben by a cost-effective hemoglobin-based biosensor. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016; 69:122-7. [DOI: 10.1016/j.msec.2016.06.061] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2016] [Revised: 05/28/2016] [Accepted: 06/20/2016] [Indexed: 10/21/2022]
|
25
|
Control over fuel cell performance through modulation of pore accessibility: investigation and modeling of carbon nanotubes effects on oxygen reduction at N-graphene-based nanocomposite. NANOTECHNOLOGY 2016; 27:475401. [PMID: 27767018 DOI: 10.1088/0957-4484/27/47/475401] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The lack of performance of graphene-based electrocatalysts for oxygen reduction (ORR) is a major concern for fuel cells which can be mastered using nanocomposites. This work is highlighted by the optimization of nitrogen(N)-doped graphene/carbon nanotubes (CNTs) nanocomposite's ORR performance examined by galvanostatic measurements in realistically approached glucose half-cells. Obtained results mark an essential step for the development of nanocarbon-based cathodes, as we specifically evaluate the electrode performance under real fuel cell conditions. The 2D simulations exclusively represent an important approach for understanding the catalytic efficiency of the nanocomposite with unique structure. The kinetics features extracted from simulations are consistent with the experimentally determined kinetics. The morphology analysis reveals a 3D porous structure. The results demonstrate that the incorporation of CNTs implements mesoscale channels for improved mass transport and leads to efficient 4-electron transfer and enhanced overall catalytic activity in pH-neutral media. The nanocomposite shows increased specific surface area of 142 m2 g-1, positively shifted ORR onset potential of 67 mV and higher open circuit potential of 268 mV versus Ag/AgCl compared to N-graphene (11 m2 g-1, -17, 220 mV). The findings are supported by 2D simulations giving qualitative evidence to the significant role of CNTs for achieving better accessibility of pores, i.e. enabling improved transfer of oxygen and OH-, and providing more reaction sites in the nanocomposite. The nanocomposite demonstrates better ORR performance than constituent components regarding potential application in miniaturized single-compartment glucose-based fuel cells.
Collapse
|
26
|
|
27
|
Low-Volume Label-Free Detection of Molecule-Protein Interactions on Microarrays by Imaging Reflectometric Interferometry. SLAS Technol 2016; 22:437-446. [PMID: 27418371 DOI: 10.1177/2211068216657512] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
This system allows the high-throughput protein interaction analysis on microarrays. We apply the interference technology 1λ-imaging reflectometric interferometry (iRIf) as a label-free detection method and create microfluidic flow cells in microscope slide format for low reagent consumption and lab work compatibility. By now, most prominent for imaging label-free interaction analyses on microarrays are imaging surface plasmon resonance (SPR) methods, quartz crystal microbalance, or biolayer interferometry. SPR is sensitive against temperature drifts and suffers from plasmon crosstalk, and all systems lack array size (maximum 96 spots). Our detection system is robust against temperature drifts. Microarrays are analyzed with a spatial resolution of 7 µm and time resolution of ≤50 fps. System sensitivity is competitive, with random noise of <5 × 10-5 and baseline drift of <3 × 10-6. Currently available spotting technologies limit array sizes to ~4 spots/mm2 (1080 spots/array); our detection system would allow ~40 spots/mm2 (10,800 spots/array). The microfluidic flow cells consist of structured PDMS inlays sealed by versatilely coated glass slides immobilizing the microarray. The injection protocol determines reagent volumes, priming rates, and flow cell temperatures for up to 44 reagents; volumes of ≤300 µL are validated. The system is validated physically by the biotinylated bovine serum albumin streptavidin assay and biochemically by thrombin aptamer interaction analysis, resulting in a KD of ~100 nM.
Collapse
|
28
|
Lift-Off Free Fabrication Approach for Periodic Structures with Tunable Nano Gaps for Interdigitated Electrode Arrays. ACS NANO 2016; 10:1086-1092. [PMID: 26625012 DOI: 10.1021/acsnano.5b06405] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
We report a simple, low-cost and lift-off free fabrication approach for periodic structures with adjustable nanometer gaps for interdigitated electrode arrays (IDAs). It combines an initial structure and two deposition process steps; first a dielectric layer is deposited, followed by a metal evaporation. The initial structure can be realized by lithography or any other structuring technique (e.g., nano imprint, hot embossing or injection molding). This method allows the fabrication of nanometer sized gaps and completely eliminates the need for a lift-off process. Different substrate materials like silicon, Pyrex or polymers can be used. The electrode gap is controlled primarily by sputter deposition of the initial structure, and thus, adjustable gaps in the nanometer range can be realized independently of the mask or stamp pattern. Electrochemical characterizations using redox cycling in ferrocenemethanol (FcMeOH) demonstrate signal amplification factors of more than 110 together with collection factors higher than 99%. Furthermore, the correlation between the gap width and the amplification factor was studied to obtain an electrochemical performance assessment of the nano gap electrodes. The results demonstrate an exponential relationship between amplification factor and gap width.
Collapse
|
29
|
Effect of the aromatic precursor flow rate on the morphology and properties of carbon nanostructures in plasma enhanced chemical vapor deposition. RSC Adv 2016. [DOI: 10.1039/c6ra02999j] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Understanding the effects of the synthesis parameters on the morphology and electrochemical properties of nanocarbon layers is a key step in the development of application-tailored nanostructures.
Collapse
|
30
|
Track A. Biomaterials and Biocompatibility. BIOMED ENG-BIOMED TE 2016; 61:1-15. [DOI: 10.1515/bmt-2016-5000] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
31
|
A nitrogen-doped graphene electrocatalyst for selective oxygen reduction in presence of glucose and D-gluconic acid in pH-neutral media. Electrochim Acta 2015. [DOI: 10.1016/j.electacta.2015.11.017] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
32
|
Self-assembled magnetic bead chains for sensitivity enhancement of microfluidic electrochemical biosensor platforms. LAB ON A CHIP 2015; 15:4314-4321. [PMID: 26394820 DOI: 10.1039/c5lc00796h] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
In this paper, we present a novel approach to enhance the sensitivity of microfluidic biosensor platforms with self-assembled magnetic bead chains. An adjustable, more than 5-fold sensitivity enhancement is achieved by introducing a magnetic field gradient along a microfluidic channel by means of a soft-magnetic lattice with a 350 μm spacing. The alternating magnetic field induces the self-assembly of the magnetic beads in chains or clusters and thus improves the perfusion and active contact between the analyte and the beads. The soft-magnetic lattices can be applied independent of the channel geometry or chip material to any microfluidic biosensing platform. At the same time, the bead-based approach achieves chip reusability and shortened measurement times. The bead chain properties and the maximum flow velocity for bead retention were validated by optical microscopy in a glass capillary. The magnetic actuation system was successfully validated with a biotin-streptavidin model assay on a low-cost electrochemical microfluidic chip, fabricated by dry-film photoresist technology (DFR). Labelling with glucose oxidase (GOx) permits rapid electrochemical detection of enzymatically produced H2O2.
Collapse
|
33
|
Photodynamic Therapy – In Vitro Investigation Using an Electrochemical Microsensor System. ACTA ACUST UNITED AC 2015. [DOI: 10.1016/j.proeng.2015.08.671] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
34
|
Optimization Study for Work Function Based CO 2 Sensing Using CuO-nanoparticles in Respect to Humidity and Temperature. ACTA ACUST UNITED AC 2015. [DOI: 10.1016/j.proeng.2015.08.706] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
35
|
|
36
|
Work Function Based CO2 Gas Sensing Using Metal Oxide Nanoparticles at Room Temperature. ACTA ACUST UNITED AC 2015. [DOI: 10.1016/j.matpr.2015.09.002] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
37
|
|
38
|
Integrated Electrochemical Pumping and Dosing System Using Phaseguide Techniques with Inherent Implemented Valving and Metering. ACTA ACUST UNITED AC 2014. [DOI: 10.2174/187640290602141127115111] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
39
|
Targeting tumour hypoxia to prevent cancer metastasis. From biology, biosensing and technology to drug development: the METOXIA consortium. J Enzyme Inhib Med Chem 2014; 30:689-721. [PMID: 25347767 DOI: 10.3109/14756366.2014.966704] [Citation(s) in RCA: 83] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2014] [Accepted: 09/15/2014] [Indexed: 01/06/2023] Open
Abstract
The hypoxic areas of solid cancers represent a negative prognostic factor irrespective of which treatment modality is chosen for the patient. Still, after almost 80 years of focus on the problems created by hypoxia in solid tumours, we still largely lack methods to deal efficiently with these treatment-resistant cells. The consequences of this lack may be serious for many patients: Not only is there a negative correlation between the hypoxic fraction in tumours and the outcome of radiotherapy as well as many types of chemotherapy, a correlation has been shown between the hypoxic fraction in tumours and cancer metastasis. Thus, on a fundamental basis the great variety of problems related to hypoxia in cancer treatment has to do with the broad range of functions oxygen (and lack of oxygen) have in cells and tissues. Therefore, activation-deactivation of oxygen-regulated cascades related to metabolism or external signalling are important areas for the identification of mechanisms as potential targets for hypoxia-specific treatment. Also the chemistry related to reactive oxygen radicals (ROS) and the biological handling of ROS are part of the problem complex. The problem is further complicated by the great variety in oxygen concentrations found in tissues. For tumour hypoxia to be used as a marker for individualisation of treatment there is a need for non-invasive methods to measure oxygen routinely in patient tumours. A large-scale collaborative EU-financed project 2009-2014 denoted METOXIA has studied all the mentioned aspects of hypoxia with the aim of selecting potential targets for new hypoxia-specific therapy and develop the first stage of tests for this therapy. A new non-invasive PET-imaging method based on the 2-nitroimidazole [(18)F]-HX4 was found to be promising in a clinical trial on NSCLC patients. New preclinical models for testing of the metastatic potential of cells were developed, both in vitro (2D as well as 3D models) and in mice (orthotopic grafting). Low density quantitative real-time polymerase chain reaction (qPCR)-based assays were developed measuring multiple hypoxia-responsive markers in parallel to identify tumour hypoxia-related patterns of gene expression. As possible targets for new therapy two main regulatory cascades were prioritised: The hypoxia-inducible-factor (HIF)-regulated cascades operating at moderate to weak hypoxia (<1% O(2)), and the unfolded protein response (UPR) activated by endoplasmatic reticulum (ER) stress and operating at more severe hypoxia (<0.2%). The prioritised targets were the HIF-regulated proteins carbonic anhydrase IX (CAIX), the lactate transporter MCT4 and the PERK/eIF2α/ATF4-arm of the UPR. The METOXIA project has developed patented compounds targeting CAIX with a preclinical documented effect. Since hypoxia-specific treatments alone are not curative they will have to be combined with traditional anti-cancer therapy to eradicate the aerobic cancer cell population as well.
Collapse
|
40
|
Sensitive, rapid and quantitative detection of substance P in serum samples using an integrated microfluidic immunochip. Biosens Bioelectron 2014; 58:186-92. [DOI: 10.1016/j.bios.2014.02.058] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2013] [Revised: 02/05/2014] [Accepted: 02/17/2014] [Indexed: 11/26/2022]
|
41
|
|
42
|
|
43
|
A micro-cantilever sensor chip based on contact angle analysis for a label-free troponin I immunoassay. LAB ON A CHIP 2013; 13:834-842. [PMID: 23282576 DOI: 10.1039/c2lc40767a] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Cantilever sensors have been extensively explored as a promising technique for real-time and label-free analyses in biological systems. A major sensing principle utilized by state-of-the-art cantilever sensors is based on analyte-induced surface stress changes, which result in static bending of a cantilever. The sensor performance, however, suffers from the intrinsically small change in surface stress induced by analytes, especially for molecular recognition such as antigen-antibody binding. Through the contact angle change on a tailored solid surface, it is possible to convert a tiny surface stress into a capillary force-a much larger physical quantity needed for a practical sensor application. In this work, a micro-cantilever sensor based on contact angle analysis (CAMCS) was proposed to effectively enhance the sensitivity of a sensor in proportion to the square of the length to thickness ratio of the cantilever structure. CAMCS chips were fabricated using a standard complementary-metal-oxide-semiconductor (CMOS) process to demonstrate a 1250-fold enhancement in the sensitivity of surface stress to bioanalyte adsorption using a piezoresistive sensing method. A real-time and label-free troponin I (cTnI) immunoassay, which is now widely used in clinics and considered a gold standard for the early diagnosis and prognosis of cardiovascular disease, was performed to demonstrate cTnI detection levels as low as 1 pg mL(-1). The short detection time of this assay was within several minutes, which matches the detection time of commercially available instruments that are based on fluorescence-labeling techniques.
Collapse
|
44
|
Monitored Water Vapour Barrier Coatings for Flexible Micro-Implants. BIOMED ENG-BIOMED TE 2013; 58 Suppl 1:/j/bmte.2013.58.issue-s1-C/bmt-2013-4087/bmt-2013-4087.xml. [DOI: 10.1515/bmt-2013-4087] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
45
|
Prolongation of electrode lifetime in biofuel cells by periodic enzyme renewal. Appl Microbiol Biotechnol 2012; 96:841-9. [DOI: 10.1007/s00253-012-4374-8] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2012] [Revised: 08/13/2012] [Accepted: 08/13/2012] [Indexed: 11/29/2022]
|
46
|
Production and Characterization of Encapsulation Layers for Micro-Implants. BIOMED ENG-BIOMED TE 2012. [DOI: 10.1515/bmt-2012-4122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
47
|
O21. Total vascular resistance and multigate spectral doppler analysis (MSDA) as a screening tool for preeclampsia: A pilot study. Pregnancy Hypertens 2011; 1:267. [DOI: 10.1016/j.preghy.2011.08.053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
48
|
A highly efficient buckypaper-based electrode material for mediatorless laccase-catalyzed dioxygen reduction. Biosens Bioelectron 2011; 26:4133-8. [DOI: 10.1016/j.bios.2011.04.008] [Citation(s) in RCA: 82] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2011] [Revised: 04/06/2011] [Accepted: 04/06/2011] [Indexed: 11/28/2022]
|
49
|
P7. An approach to distinguish and monitor NO from -levels in pericellular region. Nitric Oxide 2011. [DOI: 10.1016/j.niox.2011.03.238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
50
|
Immunohistochemical expression of Annexin A5 in preeclamptic placentas. Placenta 2011; 32:264-8. [PMID: 21216005 DOI: 10.1016/j.placenta.2010.12.015] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2010] [Revised: 12/10/2010] [Accepted: 12/10/2010] [Indexed: 11/19/2022]
Abstract
OBJECTIVE To study the expression of Annexin A5 (A5) in relation to preeclampsia using immunohistochemical Tissue Microarray (TMA) technique. STUDY DESIGN Case-control study of 66 singleton preeclamptic (PE) patients matched for gestational age (GA) at delivery with 63 normotensive controls with normally grown fetuses. Immunohistochemical expression of A5 and other population characteristics were compared between the two groups using Chi-square, One-way ANOVA, Spearman's Correlation, and Linear Regression. RESULTS The two groups were similar for maternal age and rate of corticosteroid administration, but differed for nulliparity, Body Mass Index (BMI), blood pressure, presence of placental histological lesions, and placental weight. Expression of A5 was similar in PE and controls (p = 0.10); however it was found to be lower in PE cases complicated by fetal growth restriction (FGR, n = 34) compared with matched controls (n = 55) (p = 0.04). An inverse correlation was found between A5 and GA in cases but not in controls (p = 0.04 vs p = 0.71). The association was even more significant in the subgroup of PE complicated by FGR (p = 0.02). A5 expression was not influenced by blood pressure, proteinuria, or placental weight. CONCLUSIONS Annexin A5 expression seems to be related only to FGR and not to PE or its clinical severity.
Collapse
|