1
|
Stereotactic body radiotherapy with CyberKnife ® System for low- and intermediate-risk prostate cancer: clinical outcomes and toxicities of CyPro Trial. Front Oncol 2023; 13:1270498. [PMID: 38023175 PMCID: PMC10660677 DOI: 10.3389/fonc.2023.1270498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Accepted: 09/11/2023] [Indexed: 12/01/2023] Open
Abstract
Simple summary Stereotactic body radiotherapy (SBRT) of 35-36.25 Gy in five fractions with the CyberKnife System yields excellent control with low toxicity in low-intermediate-risk prostate cancer patients. We found no differences in biochemical control and overall survival in relation to dose. There were no significant differences in toxicity or quality of life between the two groups. Aims Stereotactic body radiotherapy (SBRT) is an emerging therapeutic approach for low- and intermediate-risk prostate cancer. We present retrospective data on biochemical control, toxicity, and quality of life of CyPro Trial. Materials and methods A total of 122 patients with low- and intermediate-risk prostate cancer were treated with the CyberKnife System at a dose of 35 Gy or 36.25 Gy in five fractions. Biochemical failure (BF)/biochemical disease-free survival (bDFS) was defined using the Phoenix method (nadir + 2 ng/ml). Acute/late rectal and urinary toxicities were assessed by the Radiation Therapy Oncology Group (RTOG) toxicity scale. Quality of life (QoL) was assessed by the European Organisation for Research and Treatment of Cancer (EORTC) QLQ C30 and PR25. International Erectile Function Index-5 (IIEF5) and International Prostate Symptom Score (IPSS) questionnaires were administered at baseline, every 3 months after treatment during the first years, and then at 24 months and 36 months. Results The 1-, 2-, and 5-year DFS rates were 92.9%, 92.9%, and 92.3%, respectively, while the 1-, 2-, and 5-year bDFS rates were 100%, 100%, and 95.7%, respectively. With regard to risk groups or doses, no statistically significant differences were found in terms of DFS or bDFS. Grade 2 urinary toxicity was acute in 10% and delayed in 2% of patients. No Grade 3 acute and late urinary toxicity was observed. Grade 2 rectal toxicity was acute in 8% and late in 1% of patients. No Grade 3-4 acute and late rectal toxicity was observed. Grade 2 acute toxicity appeared higher in the high-dose group (20% in the 36.25-Gy group versus 3% in the 35-Gy group) but was not statistically significant. Conclusion Our study confirms that SBRT of 35-36.25 Gy in five fractions with the CyberKnife System produces excellent control with low toxicity in patients with low-intermediate-risk prostate cancer. We found no dose-related differences in biochemical control and overall survival. Further confirmation of these results is awaited through the prospective phase of this study, which is still ongoing.
Collapse
|
2
|
Reirradiation of Locally Recurrent Prostate Cancer with Cyberknife® System or Volumetric Modulated Arc Therapy (VMAT) and IGRT-Clarity®: Outcomes, Toxicities and Dosimetric Evaluation. Cancers (Basel) 2022; 14:cancers14133187. [PMID: 35804958 PMCID: PMC9264827 DOI: 10.3390/cancers14133187] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2022] [Revised: 06/23/2022] [Accepted: 06/27/2022] [Indexed: 02/06/2023] Open
Abstract
The management of prostate cancer recurrence following external beam radiotherapy is not defined yet. Stereotaxic body reirradiation therapy showed encouraging results for local and biochemical control. From April 2017 to December 2020, 29 patients with prostate cancer recurrence were collected, joining the retrospective studies CyPro (prot. 46/19 OSS) and CLARO (Prot. 19/20 OSS) trials. Patients received Cyberknife® treatment (17 pts) or alternatively VMAT (Volumetric Modulated Arc Technique) therapy by IGRT (Image-Guided Radiation Therapy)/Clarity® (12 pts). By comparing the reirradiation of two groups, urinary (GU), rectal (GI) toxicities, and biochemical control were investigated. Further, the two techniques were dosimetrically compared by rival plans. The VMAT-IGRT Clarity® treatments were replanned with an optimized template developed for prostate VMAT-SBRT in FFF mode keeping the same dose and fractionation scheduled for Cyberknife Group (30 Gy in 5 fx, at 80% isodose). In the CK group, 23% of patients experienced grade 2 acute GU, while 6% grade 2 acute GI. In the VMAT-Clarity® group, acute GU toxicity was recorded in 17%, while for 8% grade 2 late toxicity was recorded. The dosimetric analysis shows that the VMAT-FFF allows to deliver a biological equivalent dose to CK, with the advantage of reducing the likelihood of toxicities arising.
Collapse
|
3
|
PD-0563 QA primary program for a skin surface brachytherapy plan. Radiother Oncol 2022. [DOI: 10.1016/s0167-8140(22)02878-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
4
|
Setting up an Italian end-to-end dosimetric audit for IMRT and VMAT: the experience of the OPRORA project. Phys Med 2021. [DOI: 10.1016/s1120-1797(22)00508-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
5
|
Acute Toxicity in Hypofractionated/Stereotactic Prostate Radiotherapy of Elderly Patients: Use of the Image-guided Radio Therapy (IGRT) Clarity System. In Vivo 2021; 35:1849-1856. [PMID: 33910872 DOI: 10.21873/invivo.12447] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Revised: 03/17/2021] [Accepted: 03/25/2021] [Indexed: 11/10/2022]
Abstract
BACKGROUND The use of intra-fractional monitoring and correction of prostate position with the Image Guided Radio Therapy (IGRT) system can increase the spatial accuracy of dose delivery. Clarity is a system used for intrafraction prostate-motion management, it provides a real-time visualization of prostate with a transperineal ultrasound. The aim of this study was to evaluate the use of Clarity-IGRT on proper intrafraction alignment and monitoring, its impact on Planning Tumor Volume margin and on urinary and rectal toxicity in elderly patients not eligible for surgery. PATIENTS AND METHODS Twenty-five elderly prostate cancer patients, median age=75 years (range=75-90 years) were treated with Volumetric Radiotherapy and Clarity-IGRT using 3 different schemes: A) 64.5/72 Gray (Gy) in 30 fractions on prostate and seminal vesicles (6 patients); B) 35 Gy in 5 fractions on prostate and seminal vesicles (12 patients); C): 35 Gy in 5 fractions on prostate (7 patients). Ultrasound identification of the overlapped structures to the detected ones during simulation has been used in each session. A specific software calculates direction and entity of necessary shift to obtain the perfect match. The average misalignment in the three-dimensional space has been determined and shown in a box-plot. RESULTS All patients completed treatment with mild-moderate toxicity. During treatment, genitourinary toxicity was 32% Grade 1; 4% Grade 2, rectal was 4% Grade 1. At follow-up of 3 months, genitourinary toxicity was 20% Grade 1; 4% Grade 2, rectal toxicity was 4% Grade 2. At follow-up of 6 months, genitourinary toxicity was 4% Grade 1; 4% Grade 2. Rectal toxicity was 4% Grade 2. CONCLUSION Radiotherapy with the Clarity System allows a reduction of PTV margins, the amount of fractions can be reduced increasing the total dose, not exacerbating urinary and rectal toxicity with greater patient's compliance.
Collapse
|
6
|
Dosimetric comparison among cyberknife, helical tomotherapy and VMAT for hypofractionated treatment in localized prostate cancer. Medicine (Baltimore) 2020; 99:e23574. [PMID: 33327317 PMCID: PMC7738085 DOI: 10.1097/md.0000000000023574] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Hypofractionation for localized prostate cancer treatment is rapidly spreading in the medical community and it is supported by radiobiological evidences (lower α/β ratio compared with surrounding tissues). Stereotactic body radiation therapy (SBRT) is a technique to administer high doses with great precision, which is commonly performed with CyberKnife (CK) in prostate cancer treatment. Since the CyberKnife (CK) is not available at all radiotherapy center, alternative SBRT techniques are available such as Volumetric Modulated Arc Therapy (VMAT) and Helical Tomotherapy (HT). The aim of the present study was to compare the dosimetric differences between the CK, VMAT, and HT plans for localized prostate cancer treatment.Seventeenpatients have been recruited and replanned using VMAT and HT to this purpose: they received the treatment using the CK with a prescription of 36.25 Gy in 5 fractions; bladder, rectum and penis bulb were considered as organs at risk (OAR). In order to compare the techniques, we considered DVHs, PTV coverage, Conformity Index and new Conformity Index, Homogeneity Index, beam-on time and OARs received dose.The 3 treatments methods showed a comparable coverage of the lesion (PTV 95%: 99.8 ± 0.4% CK; 98.5 ± 0.8% VMAT; 99.4 ± 0.5% HT. P < .05) and good sparing of OARs. Nevertheless, the beam-on time showed a significant difference (37 ± 9 m CK; 7.1 ± 0.3 m VMAT; 17 ± 2 m HT. P < .05).Our results showed that, although CK is the best SBRT technique for prostate cancer treatment, in case this technology is not available, it can be replaced by a similar treatment delivered by VMAT technique. VMAT can be administrated only if it has an appropriate Image Guided Radiation Therapy (IGRT) tracking system.
Collapse
|
7
|
Automatic genetic planning for volumetric modulated arc therapy: A large multi-centre validation for prostate cancer. Radiother Oncol 2020; 148:126-132. [PMID: 32361572 DOI: 10.1016/j.radonc.2020.04.020] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2020] [Revised: 04/15/2020] [Accepted: 04/16/2020] [Indexed: 11/25/2022]
Abstract
PURPOSE The first clinical genetic autoplanning algorithm (Genetic Planning Solution, GPS) was validated in ten radiotherapy centres for prostate cancer VMAT by comparison with manual planning (Manual). METHODS Although there were large differences among centres in planning protocol, GPS was tuned with the data of a single centre and then applied everywhere without any centre-specific fine-tuning. For each centre, ten Manual plans were compared with autoGPS plans, considering dosimetric plan parameters and the Clinical Blind Score (CBS) resulting from blind clinician plan comparisons. AutoGPS plans were used as is, i.e. there was no patient-specific fine-tuning. RESULTS For nine centres, all ten plans were clinically acceptable. In the remaining centre, only one plan was acceptable. For the 91% acceptable plans, differences between Manual and AutoGPS in target coverage were negligible. OAR doses were significantly lower in AutoGPS plans (p < 0.05); rectum D15% and Dmean were reduced by 8.1% and 17.9%, bladder D25% and Dmean by 5.9% and 10.3%. According to clinicians, 69% of the acceptable AutoGPS plans were superior to the corresponding Manual plan. In case of preferred Manual plans (31%), perceived advantages compared to autoGPS were minor. QA measurements demonstrated that autoGPS plans were deliverable. A quick configuration adjustment in the centre with unacceptable plans rendered 100% of plans acceptable. CONCLUSION A novel, clinically applied genetic autoplanning algorithm was validated in 10 centres for in total 100 prostate cancer patients. High quality plans could be generated at different centres without centre-specific algorithm tuning.
Collapse
|
8
|
Lithium chloride increases sensitivity to photon irradiation treatment in primary mesenchymal colon cancer cells. Mol Med Rep 2020; 21:1501-1508. [PMID: 32016459 PMCID: PMC7002976 DOI: 10.3892/mmr.2020.10956] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Accepted: 11/26/2019] [Indexed: 12/27/2022] Open
Abstract
Colorectal cancer (CRC) is the third most prevalent type of cancer worldwide. It is also the second most common cause of cancer-associated mortality; it accounted for about 9.2% of all cancer deaths in 2018, most of which were due to resistance to therapy. The main treatment for CRC is surgery, generally associated with chemotherapy, radiation therapy and combination therapy. However, while chemo-radiotherapy kills differentiated cancer cells, mesenchymal stem-like cells are resistant to this treatment, and this can give rise to therapy-resistant tumors. Our previous study isolated T88 primary colon cancer cells from a patient with sporadic colon cancer. These cells exhibited mesenchymal and epithelial features, high levels of epithelial-to-mesenchymal transition transcription factors, and stemness markers. In addition, it was revealed that lithium chloride (LiCl), a specific glycogen synthase kinase (GSK)-3β inhibitor, induced both the mesenchymal-to-epithelial transition and differentiation, and also reduced cell migration, stemness features and cell plasticity in these primary colon cancer cells. The aim of the present study was to investigate the effect of LiCl treatment on the viability of primary colon cancer cells exposed to 7 Gy delivered by high-energy photon beams, which corresponds to 6 megavolts of energy. To achieve this aim, the viability of irradiated T88 cells was compared with that of irradiated T88 cells pre-treated with LiCl. As expected, it was observed that LiCl sensitized primary colon cancer cells to high-energy photon irradiation treatment. Notably, the decrease in cell viability was greater with combined therapy than with irradiation alone. To explore the molecular basis of this response, the effect of LiCl on the expression of Bax, p53 and Survivin, which are proteins involved in the apoptotic mechanism and in death escape, was analyzed. The present study revealed that LiCl upregulated the expression of pro-apoptotic proteins and downregulated the expression of proteins involved in survival. These effects were enhanced by high-energy photon irradiation, suggesting that LiCl could be used to sensitize colon cancer cells to radiation therapy.
Collapse
|
9
|
Abstract
Prostate cancer is the second highest cause of cancer mortality after lung tumours. In USA it affects about 2.8 million men and the incidence increases with age in many countries. Therefore, early diagnosis is a very important step for patient clinical evaluation and for a selective and efficient therapy. The study of miRNAs' functions and molecular mechanisms has brought new knowledge in biological processes of cancer. In prostate cancer there is a deregulation of several miRNAs that may function as tumour suppressors or oncogenes. The aim of this review is to analyze the progress made to our understanding of the role of miRNA dysregulation in prostate cancer tumourigenesis.
Collapse
|
10
|
Metabolic syndrome, endocrine disruptors and prostate cancer associations: biochemical and pathophysiological evidences. Oncotarget 2018; 8:30606-30616. [PMID: 28389628 PMCID: PMC5444769 DOI: 10.18632/oncotarget.16725] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2016] [Accepted: 02/06/2017] [Indexed: 01/18/2023] Open
Abstract
This review summarizes the main pathophysiological basis of the relationship between metabolic syndrome, endocrine disruptor exposure and prostate cancer that is the most common cancer among men in industrialized countries. Metabolic syndrome is a cluster of metabolic and hormonal factors having a central role in the initiation and recurrence of many western chronic diseases including hormonal-related cancers and it is considered as the worlds leading health problem in the coming years. Many biological factors correlate metabolic syndrome to prostate cancer and this review is aimed to focus, principally, on growth factors, cytokines, adipokines, central obesity, endocrine abnormalities and exposure to specific endocrine disruptors, a cluster of chemicals, to which we are daily exposed, with a hormone-like structure influencing oncogenes, tumor suppressors and proteins with a key role in metabolism, cell survival and chemo-resistance of prostate cancer cells. Finally, this review will analyze, from a molecular point of view, how specific foods could reduce the relative risk of incidence and recurrence of prostate cancer or inhibit the biological effects of endocrine disruptors on prostate cancer cells. On the basis of these considerations, prostate cancer remains a great health problem in terms of incidence and prevalence and interventional studies based on the treatment of metabolic syndrome in cancer patients, minimizing exposure to endocrine disruptors, could be a key point in the overall management of this disease.
Collapse
|
11
|
Role of DNA repair machinery and p53 in the testicular germ cell cancer: a review. Oncotarget 2018; 7:85641-85649. [PMID: 27821802 PMCID: PMC5356765 DOI: 10.18632/oncotarget.13063] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2016] [Accepted: 10/19/2016] [Indexed: 12/21/2022] Open
Abstract
Notwithstanding the peculiar sensitivity to cisplatin-based treatment, resulting in a very high percentage of cures even in advanced stages of the disease, still we do not know the biological mechanisms that make Testicular Germ Cell Tumor (TGCT) “unique” in the oncology scene. p53 and MDM2 seem to play a pivotal role, according to several in vitro observations, but no correlation has been found between their mutational or expression status in tissue samples and patients clinical outcome. Furthermore, other players seem to be on stage: DNA Damage Repair Machinery (DDR) , especially Homologous Recombination (HR) proteins, above all Ataxia Telangiectasia Mutated (ATM), cooperates with p53 in response to DNA damage, activating apoptotic cascade and contributing to cell “fate”. Homologous Recombination deficiency has been assumed to be a Germ Cell Tumor characteristic underlying platinum-sensitivity, whereby Poly(ADP-ribose) polymerase (PARP), an enzyme involved in HR DNA repair, is an intriguing target: PARP inhibitors have already entered in clinical practice of other malignancies and trials are recruiting TGCT patients in order to validate their role in this disease. This paper aims to summarize evidence, trying to outline an overview of DDR implications not only in TGCT curability, but also in resistance to chemotherapy.
Collapse
|
12
|
Radiosurgery and stereotactic radiotherapy with cyberknife system for meningioma treatment. Neuroradiol J 2017; 31:18-26. [PMID: 29206077 DOI: 10.1177/1971400917744885] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Objective The aim of this work was to evaluate the impact of stereotactic radiosurgery/fractionated stereotactic radiotherapy with the Cyberknife system on local disease control, clinical outcome and toxicity in patients with meningioma, according to the site and histological grade of lesion. From January 2013 to April 2017, 52 patients with intracranial meningiomas were treated with the Cyberknife system. Twenty-four patients had undergone previous surgery: 38% gross total resection, 10% subtotal resection; 27 patients underwent no surgery; 22 patients had a recurrence of meningioma. Methods Radiosurgery was used for lesions smaller than 2 cm, stereotactic radiotherapy for lesions larger than 2 cm, or smaller but close to a critical site such as the optical chiasm, optic pathway or brainstem. Results Local control and clinical outcomes were analysed. Median follow-up was 20 months: six patients died, one after re-surgery died from post-surgical sepsis, three from heart disease. Progression-free survival had a mean value of 38.3 months and overall survival of 41.6 months. We evaluated at 12 months 28 patients (100% local control); at 24 months 19 patients (89% local control); at 36 months nine patients (89% local control). At baseline, 44/52 patients (85%) were symptomatic: 19 visual disorders, 17 motor disorders, six hearing disorders, 10 headache and six epilepsy. Visual symptoms remained unchanged in 52%, improved in 32%, resolved in 16%. Headache was improved in 40%, resolved in 10%, unchanged in 50%. Epilepsy was resolved in 17%, unchanged in 33%, worsened in 33%. Conclusions Stereotactic radiosurgery/fractionated stereotactic radiotherapy with Cyberknife provides a good local disease control, improving visual, hearing and motor symptoms.
Collapse
|
13
|
Correction: Metabolic syndrome, endocrine disruptors and prostate cancer associations: biochemical and pathophysiological evidences. Oncotarget 2017; 8:62816. [PMID: 28977991 PMCID: PMC5617551 DOI: 10.18632/oncotarget.20631] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
[This corrects the article DOI: 10.18632/oncotarget.16725.].
Collapse
|
14
|
Rectal/urinary toxicity after hypofractionated vs conventional radiotherapy in low/intermediate risk localized prostate cancer: systematic review and meta analysis. Oncotarget 2017; 8:17383-17395. [PMID: 28129649 PMCID: PMC5370048 DOI: 10.18632/oncotarget.14798] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2016] [Accepted: 12/07/2016] [Indexed: 12/18/2022] Open
Abstract
Purpose The aim of this review was to compare radiation toxicity in Localized Prostate Cancer (LPC) patients who underwent conventional fractionation (CV), hypofractionated (HYPO) or extreme hypofractionated (eHYPO) radiotherapy. We analyzed the impact of technological innovation on the management of prostate cancer, attempting to make a meta-analysis of randomized trials. Methods PubMed database has been explored for studies concerning acute and late urinary/gastrointestinal toxicity in low/intermediate risk LPC patients after receiving radiotherapy. Studies were then gathered into 5 groups: detected acute and chronic toxicity data from phase II non randomized trials were analyzed and Odds Ratio (OR) was calculated by comparing the number of patients with G0-1 toxicity and those with toxicity > G2 in the studied groups. A meta-analysis of prospective randomized trials was also carried out. Results The initial search yielded 575 results, but only 32 manuscripts met all eligibility requirements: in terms of radiation-induced side effects, such as gastrointestinal and genitourinary acute and late toxicity, hypofractionated 3DCRT seemed to be more advantageous than 3DCRT with conventional fractionation as well as IMRT with conventional fractionation compared to 3DCRT with conventional fractionation; furthermore, IMRT hypofractionated technique appeared more advantageous than IMRT with conventional fractionation in late toxicities. Randomized trials meta-analysis disclosed an advantage in terms of acute gastrointestinal and late genitourinary toxicity for Hypofractionated schemes. Conclusions Although our analysis pointed out a more favorable toxicity profile in terms of gastrointestinal acute side effects of conventional radiotherapy schemes compared to hypofractionated ones, prospective randomized trials are needed to better understand the real incidence of rectal and urinary toxicity in patients receiving radiotherapy for localized prostate cancer.
Collapse
|
15
|
Rectal/urinary toxicity after hypofractionated vs. conventional radiotherapy in high risk prostate cancer: systematic review and meta analysis. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES 2017; 21:3563-3575. [PMID: 28925488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
OBJECTIVE The aim of our report was to review the literature concerning the toxicity of radiation therapy in patients treated for high-risk prostate cancer, and to evaluate the differences in toxicity between conventional fractionation and hypofractionated treatments, in view of different techniques used in high-risk prostate cancer patients. MATERIALS AND METHODS PubMed database has been explored for studies concerning acute and late urinary/gastrointestinal toxicity in high-risk prostate cancer patients treated with radiotherapy. Prospective studies, concerning potential relationship between acute/late genitourinary (GU)/gastrointestinal (GI) toxicity and prostate radiotherapy in patients with high-risk prostate cancer, were included in the final analysis. Data collected from single arm, phase II non-randomized and randomized studies have been evaluated to perform odds ratio for toxicity risk. Furthermore, meta-analysis randomized prospective trials were considered suitable because they had recruited high-risk prostate cancer patients who didn't undergo surgery, with available data on ≥ G2 toxicity frequency. RESULTS The initial search provided 606 results, but only 35 manuscripts met all eligibility requirements and were included in this report. In order to perform odds ratio we observed a decrease in late gastrointestinal toxicity for patients treated with hypofractionated schemes compared to CV treated ones. Among patients who underwent conventional treatment, SIB seemed to decrease acute genitourinary side effects; SIB-Hypo treated patients suffered less toxicity than patients treated with hypofractionated- sequential boost schemes. Hypo-SIB schemes would seem less toxic in terms of acute gastrointestinal and late genitourinary side effects than CV-SIB. Therefore, our focus shifted to 6 clinical trials evaluating genitourinary and gastrointestinal toxicity in patients who had been randomized to receive conventional fractionation or hypofractionated treatment, in both cases with IMRT technology. Our meta-analysis of these randomized trials involving patients with high-risk prostate cancer showed a statistically significant increase in late genitourinary toxicity for hypo-treated patients; no difference was observed in acute genitourinary/gastrointestinal toxicity, and in late gastrointestinal toxicity. CONCLUSIONS Our analysis doesn't want to establish a definitive truth; very few trials assessed only high risk-class patients. Our purpose is to stimulate further randomized prospective trials focusing both on the effectiveness and toxicity profile (toxicity/effectiveness ratio), taking into account the use of different technologies and doses.
Collapse
|
16
|
Abstract
The gold standard for the detection of urothelial carcinoma is represented by urethro-cystoscopy and biopsy. Both procedures are invasive and expensive and therefore cytology is often used as first approach to investigate on a possible neoplasia, being a safe and cost-effective diagnostic modality of evaluation. Because cytology alone is not highly sensitive for detection of low grade urothelial carcinoma and recurrence of the disease, several adjunct markers and urine based tests for urothelial carcinoma have been developed, which can help in the final diagnosis. In particular, ProEx C is an immunohistochemical cocktail containing antibodies direct against topoisomerase IIα (TOP2A) and minichromosome maintenance 2 (MCM2) proteins. It proved to be a valid biomarker especially in detecting squamous intraepithelial lesions in cervical liquid-based samples and in discerning these lesions from their mimickers, as well as in ovarian, endometrial, vulvar, primary and metastatic melanomas, breast, pancreatic and renal cell carcinomas. This brief review covers the effective utility of ProEx C as adjunct tool in assessing the urothelial lesions in urine cytology, also providing prognostic and therapeutic information to help in clinical decisions.
Collapse
|
17
|
Marginal Leakage of Class V Composite Restorations Assessed Using Microcomputed Tomography and Scanning Electron Microscope. Oper Dent 2015; 40:440-8. [DOI: 10.2341/14-022-l] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objective
The aim of the study was to compare in Class V composite restorations marginal leakage measurements obtained with microcomputed tomography (micro-CT) and scanning electron microscopy (SEM) observations.
Methods
Class V cavities were prepared on 10 human molars and restored using Optibond FL (Kerr, Orange, CA, USA) and Premise Flowable (Kerr). Sealing ability was evaluated by assessing silver-nitrate penetration depth along enamel and dentin margins. Leakage was quantified using a scoring system. Micro-CT analysis provided 502 cross-sectional images for each tooth. Microleakage evaluation was performed first on three cross-sections corresponding to the sections examined by SEM, then on all 502 of the obtained micro-CT images. SEM observations were performed first at 20× magnification, then, if showing a zero score, at 80× magnification. Enamel and dentin microleakage scores assigned to corresponding sections through micro-CT and SEM (20×) were compared (Wilcoxon signed-rank test, α=0.05).
Results
No statistically significant difference in leakage scores emerged between micro-CT and 20×-magnification SEM. Eight tooth sections that were given a zero score under SEM at 20× magnification showed to be infiltrated at the higher magnification (80×). For five teeth a higher score was assigned following scanning of 502 cross-sections than based on the observation of three sections.
Conclusions
Micro-CT presents as a valid, nondestructive in vitro method to quantitatively evaluate marginal leakage of adhesive restorations.
Collapse
|
18
|
Temperature Profiles Along the Root with Gutta-percha Warmed through Different Heat Sources. Open Dent J 2015; 8:229-35. [PMID: 25614768 PMCID: PMC4298040 DOI: 10.2174/1874210601408010229] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2014] [Revised: 11/04/2014] [Accepted: 11/17/2014] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVES To evaluate temperature profiles developing in the root during warm compaction of gutta-percha with the heat sources System B and System MB Obtura (Analityc Technology, Redmond, WA, USA). Thirty extracted human incisor teeth were used. Root canals were cleaned and shaped by means of Protaper rotary files (Dentsply-Maillefer, Belgium), and imaging was performed by micro-CT (Skyscan 1072, Aartselaar, Belgium). METHODS Teeth were instrumented with K-type thermocouples, and the roots were filled with thermoplastic gutta-percha. Vertical compaction was achieved through the heat sources System B and System MB, and temperature profiles were detect-ed by means of NI Dac Interface controlled by the LabView System. With both heat sources, higher temperature levels were recorded in the region of the root far from the apex. When the warm plugger tip was positioned at a distance of 3 mm from the root apex, temperature levels of about 180°C were used to soften gutta-percha, and no statistically significant differences were observed between peak temperatures developed by the two heating sources at the root apex. However, a temperature level higher than 40°C was maintained for a longer time with System MB. RESULTS Statistically significant differences were observed in peak temperature levels recorded far from the root apex. Thus, with a temperature of about 180°C and the warm plugger positioned at 3 mm from the root apex, both heating sources led to a temperature slightly higher than 40°C at the apex of the root, suggesting that the gutta-percha was properly softened. SIGNIFICANCE A temperature level higher than 40°C was maintained for a longer time with System MB, thus providing an ad-equate time for warm compaction of the gutta-percha.
Collapse
|
19
|
[µCT analysis of mandibular molars before and after instrumentation by Reciproc files]. RECENTI PROGRESSI IN MEDICINA 2013; 104:420-4. [PMID: 24042421 DOI: 10.1701/1315.14589] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Cleaning and shaping are important section for the root canal treatment. A number of different methodologies have been developed to overcome these problems, including the introduction of rotary instruments nickel-titanium (NiTi). In endodontics NiTi have been shown to significantly reduce procedural errors compared to manual techniques of instrumentation. The efficiency of files is related to many factor. Although previous investigations that have used µCT analysis were hampered by insufficient resolution or projection incorrect. The new generation of μCT performance best offer, as micron resolution and accurate measurement software for evaluating the accurate anatomy of the root canal. The aim the paper was to evaluate the efficiency of Reciproc files in root canal treatment, evaluated before and after instrumentation by using μ-CT analysis.
Collapse
|
20
|
Effects of intraoral aging on surface properties of coated nickel-titanium archwires. Angle Orthod 2013; 84:665-72. [PMID: 24308528 DOI: 10.2319/081213-593.1] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVE To evaluate the effects of intraoral aging on surface properties of esthetic and conventional nickel-titanium (NiTi) archwires. MATERIALS AND METHODS Five NiTi wires were considered for this study (Sentalloy, Sentalloy High Aesthetic, Superelastic Titanium Memory Wire, Esthetic Superelastic Titanium Memory Wire, and EverWhite). For each type of wire, four samples were analyzed as received and after 1 month of clinical use by an atomic force microscope (AFM) and a scanning electronic microscope (SEM). To evaluate sliding resistance, two stainless steel plates with three metallic or three monocrystalline brackets, bonded in passive configuration, were manufactured; four as-received and retrieved samples for every wire were pulled five times at 5 mm/min for 1 minute by means of an Instron 5566, recording the greatest friction value (N). Data were analyzed by one-way analysis of variance and by Student's t-test. RESULTS After clinical use, surface roughness increased considerably. The SEM images showed homogeneity for the as-received control wires; however, after clinical use esthetic wires exhibited a heterogeneous surface with craters and bumps. The lowest levels of friction were observed with the as-received Superelastic Titanium Memory Wire on metallic brackets. When tested on ceramic brackets, all the wires exhibited an increase in friction (t-test; P < .05). Furthermore, all the wires, except Sentalloy, showed a statistically significant increase in friction between the as-received and retrieved groups (t-test; P < .05). CONCLUSION Clinical use of the orthodontic wires increases their surface roughness and the level of friction.
Collapse
|
21
|
Micro-computerized tomographic analysis of premolars restored with oval and circular posts. Clin Oral Investig 2013; 18:571-8. [DOI: 10.1007/s00784-013-0982-7] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2012] [Accepted: 04/08/2013] [Indexed: 10/26/2022]
|
22
|
Evaluation of surface roughness of orthodontic wires by means of atomic force microscopy. Angle Orthod 2012; 82:922-928. [PMID: 22339276 PMCID: PMC8823114 DOI: 10.2319/100211-620.1] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2011] [Accepted: 12/01/2011] [Indexed: 09/01/2023] Open
Abstract
OBJECTIVE To compare the surface roughness of different orthodontic archwires. MATERIALS AND METHODS Four nickel-titanium wires (Sentalloy(®), Sentalloy(®) High Aesthetic, Titanium Memory ThermaTi Lite(®), and Titanium Memory Esthetic(®)), three β-titanium wires (TMA(®), Colored TMA(®), and Beta Titanium(®)), and one stainless-steel wire (Stainless Steel(®)) were considered for this study. Three samples for each wire were analyzed by atomic force microscopy (AFM). Three-dimensional images were processed using Gwiddion software, and the roughness average (Ra), the root mean square (Rms), and the maximum height (Mh) values of the scanned surface profile were recorded. Statistical analysis was performed by one-way analysis of variance (ANOVA) followed by Tukey's post hoc test (P < .05). RESULTS The Ra, Rms, and Mh values were expressed as the mean ± standard deviation. Among as-received archwires, the Stainless Steel (Ra = 36.6 ± 5.8; Rms = 48 ± 7.7; Mh = 328.1 ± 64) archwire was less rough than the others (ANOVA, P < .05). The Sentalloy High Aesthetic was the roughest (Ra = 133.5 ± 10.8; Rms = 165.8 ± 9.8; Mh = 949.6 ± 192.1) of the archwires. CONCLUSIONS The surface quality of the wires investigated differed significantly. Ion implantation effectively reduced the roughness of TMA. Moreover, Teflon(®)-coated Titanium Memory Esthetic was less rough than was ion-implanted Sentalloy High Aesthetic.
Collapse
|
23
|
Microcomputed tomography analysis of mesiobuccal orifices and major apical foramen in first maxillary molars. Open Dent J 2012; 6:118-25. [PMID: 22905069 PMCID: PMC3415628 DOI: 10.2174/1874210601206010118] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2012] [Revised: 05/20/2012] [Accepted: 05/21/2012] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVE Aim of the study was to determined by microcomputed tomography (µCT) the horizontal distance between the main (MB1) and the second mesiobuccal canal (MB2) orifices, the vertical distance between the MB1 and MB2 orifices planes, and the distance between the anatomic apex and major apical foramen (AF). Furthermore, we characterized the entire internal and external anatomy of the MB, distalbuccal (DB) and palatal (P) maxillary first molars roots. MATERIALS AND METHODS Twenty-two intact extracted first maxillary molars were scanned by X-ray computed transaxial µCT and then 2D and 3D images were processed and analyzed. RESULTS The results showed that 77.27% of the mesiobuccal (MB) roots presented a second MB canal, and 29.41% of the MB2 were independent from the MB1 canals. In 15 teeth, there were three root canal orifices on the chamber floor, and 10 of these teeth presented MB2 canals. The mean vertical distance between the MB1 and MB2 planes was 1.68 ± 0.83 mm. Seven teeth had four orifices. The mean horizontal interorificial distance between the MB1 and MB2 orifices was 1.21 ± 0.5 mm. Accessory canals were observed in 33.33% of the roots, loops in 6.06%, while isthmuses were found in 15 of the 22 MB roots. Of the total roots, 74.24% presented one foramen, while all of the roots showed a major apical foramen that was not coincident with the anatomic apex. CONCLUSIONS Our µCT analysis provided interesting features on the horizontal and vertical distance between the MB1 and MB2 orifices and on the distance of AF and anatomic apex. CLINICAL RELEVANCE These results have an important clinical value because might support the endodontist in the recruitment, negotiation and obturation of maxillary first molar canal system.
Collapse
|
24
|
Effect of autoclaving on the surfaces of TiN-coated and conventional nickel-titanium rotary instruments. Int Endod J 2012; 45:1148-55. [DOI: 10.1111/j.1365-2591.2012.02088.x] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2012] [Accepted: 05/27/2012] [Indexed: 11/29/2022]
|
25
|
IG-File: un nuovo strumento per l’ottimizzazione della detersione canalare e per la misurazione del diametro apicale. GIORNALE ITALIANO DI ENDODONZIA 2011. [DOI: 10.1016/j.gien.2011.07.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022] Open
|
26
|
Effects of sodium hypochlorite and ethylenediaminetetraacetic acid on rotary nickel-titanium instruments evaluated using atomic force microscopy. Int Endod J 2010; 44:203-9. [DOI: 10.1111/j.1365-2591.2010.01799.x] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
27
|
Effect of mineral trioxide aggregate on mesenchymal stem cells. J Endod 2010; 36:1839-43. [PMID: 20951297 DOI: 10.1016/j.joen.2010.08.010] [Citation(s) in RCA: 61] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2010] [Revised: 07/07/2010] [Accepted: 08/06/2010] [Indexed: 11/25/2022]
Abstract
INTRODUCTION Mineral trioxide aggregate (MTA) is known to stimulate the hard tissue repair process. The purpose of this study was to evaluate the ability of MTA to support the adhesion, proliferation, and migration of human bone marrow-derived mesenchymal stem cells (hMSCs). METHODS White ProRoot MTA and white Portland cement were mixed and left to set 24 hours. MSCs were cultured on the samples and observed after 24 hours by confocal laser scanning microscopy (CLSM) by using the cytoskeleton marker CellTracker. Cell proliferation was evaluated by means of alamar blue assay in the presence and absence of differentiation medium during a period of 28 days, and cells seeded on polystyrene culture wells were the control. To assess the effect on migratory ability of hMSCs, a transwell migration assay was performed for 18 hours, positioning MTA and Portland cement in 6-well plates and the cells in 8-μm pore inserts. RESULTS hMSCs observed under CLSM showed attachment and spread activity on the upper surface of the MTA. Cell proliferation was significantly higher on MTA than on Portland cement. A rate proliferation increase of the MTA group compared with the control was observed after 14 days in presence of basic medium, whereas the same effect was reached after 21 days in presence of differentiation medium. Moreover, MTA was able to enhance cell migration significantly more than Portland cement. CONCLUSIONS Our findings suggest that MTA was able to assist hMSC adhesion, growth, and migration.
Collapse
|
28
|
Poly(ε-caprolactone) reinforced with sol-gel synthesized organic-inorganic hybrid fillers as composite substrates for tissue engineering. JOURNAL OF APPLIED BIOMATERIALS & BIOMECHANICS : JABB 2010; 8:146-152. [PMID: 21337305] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Accepted: 07/19/2010] [Indexed: 05/30/2023]
Abstract
PURPOSE The importance of polymer-based composite materials to make multifunctional substrates for tissue engineering and the strategies to improve their performances have been stressed in the literature. Bioactive features of sol-gel synthesized poly(ε-caprolactone)/TiO₂ or poly(ε-caprolactone)/ZrO₂ organic-inorganic hybrid materials are widely documented. Accordingly, the aim of this preliminary research was to develop advanced composite substrates consisting of a poly(ε-caprolactone) matrix reinforced with sol-gel synthesized PCL/TiO₂ or PCL/ZrO₂ hybrid fillers. METHODS Micro-computed tomography and atomic force microscopy analyses allowed to study surface topography and roughness. On the other hand, mechanical and biological performances were evaluated by small punch tests and Alamar Blue™ assay, respectively. RESULTS Micro-computed tomography and atomic force microscopy analyses highlighted the effect of the preparation technique. Results from small punch tests and Alamar Blue™ assay evidenced that PCL reinforced with Ti2 (PCL=12, TiO₂=88 wt%) and Zr2 (PCL=12, ZrO₂=88 wt%) hybrid fillers provided better mechanical and biological performances. CONCLUSIONS PCL reinforced with Ti2 (PCL=12, TiO₂=88 wt%) and Zr2 (PCL=12, ZrO₂=88 wt%) hybrid fillers could be considered as advanced composite substrates for hard tissue engineering.
Collapse
|