1
|
PO-0605: Factors associated with late dysphagia and xerostomia in (chemo)radiation for head and neck cancer. Radiother Oncol 2017. [DOI: 10.1016/s0167-8140(17)31041-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
2
|
Abstract
Abstract
The Thetis research pool reactor (with a nominal power of 150 kW) of the Ghent University was operational from 1967 till December 2003. The first phase of the decommissioning of the reactor, the removal of the spent fuel from the site, took place in 2010. The cumulative dose received was only 404 man · μSv. During the second phase, the transition period between the removal of the spent fuel in 2010 and the start of the decommissioning phase in March 2013, 3-monthly internal inspections and inspections by Bel V, were performed. The third and final decommissioning phase started on March 18, 2013. The total dose received between March 2013 and August 2013 was 1561 man · μSv. The declassification from a Class I installation to a Class II installation was possible by the end of 2015. The activated concrete in the reactor pool will remain under regulatory control until the activation levels are lower than the limits for free release.
Collapse
|
3
|
O39. In vitro cellular radiosensitivity assays as predictor of radiotherapy related late toxicity in breast cancer patients. Phys Med 2016. [DOI: 10.1016/j.ejmp.2016.07.047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
4
|
O42. Realizing the European Network of Biological Dosimetry ‘RENEB’: Results of 2 intercomparison exercises for the micronucleus assay. Phys Med 2016. [DOI: 10.1016/j.ejmp.2016.07.050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
5
|
O38. Radiosensitivity of CD34+ hematopoietic stem and progenitor cells: A target for radiation-induced leukemia. Phys Med 2016. [DOI: 10.1016/j.ejmp.2016.07.046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
|
6
|
O40. The cytogenetic response of human T-lymphocytes to low doses of p(66)/Be neutrons and heterogeneous exposures to 60Co γ-rays. Phys Med 2016. [DOI: 10.1016/j.ejmp.2016.07.048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
|
7
|
O44. The differences in induction and repair of DNA DSB induced by 30 kV X-rays, fast neutrons and γ-rays. Phys Med 2016. [DOI: 10.1016/j.ejmp.2016.07.052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
|
8
|
Radiation Sensitivity of Human CD34+Cells Versus Peripheral Blood T Lymphocytes of Newborns and Adults: DNA Repair and Mutagenic Effects. Radiat Res 2016; 185:580-90. [DOI: 10.1667/rr14109.1] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
9
|
A comparative study of the cytogenetic responses for homo- and heterogeneous exposures of human T-lymphocytes. Phys Med 2015. [DOI: 10.1016/j.ejmp.2015.07.089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
|
10
|
SP-0169: Validating predictive models and biomarkers for radiotherapy toxicity: the REQUITE project. Radiother Oncol 2015. [DOI: 10.1016/s0167-8140(15)40167-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
11
|
The first gamma-H2AX biodosimetry intercomparison exercise of the developing European biodosimetry network RENEB. RADIATION PROTECTION DOSIMETRY 2015; 164:265-270. [PMID: 25118318 DOI: 10.1093/rpd/ncu259] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2013] [Accepted: 07/18/2014] [Indexed: 06/03/2023]
Abstract
In the event of a mass casualty radiation incident, the gamma-H2AX foci assay could be a useful tool to estimate radiation doses received by individuals. The rapid processing time of blood samples of just a few hours and the potential for batch processing, enabling high throughput, make the assay ideal for early triage categorisation to separate the 'worried well' from the low and critically exposed by quantifying radiation-induced foci in peripheral blood lymphocytes. Within the RENEB framework, 8 European laboratories have taken part in the first European gamma-H2AX biodosimetry exercise, which consisted of a telescoring comparison of 200 circulated foci images taken from 8 samples, and a comparison of 10 fresh blood lymphocyte samples that were shipped overnight to participating labs 4 or 24 h post-exposure. Despite large variations between laboratories in the dose-response relationship for foci induction, the obtained results indicate that the network should be able to use the gamma-H2AX assay for rapidly identifying the most severely exposed individuals within a cohort who could then be prioritised for accurate chromosome dosimetry.
Collapse
|
12
|
Realising the European network of biodosimetry: RENEB-status quo. RADIATION PROTECTION DOSIMETRY 2015; 164:42-5. [PMID: 25205835 PMCID: PMC4401036 DOI: 10.1093/rpd/ncu266] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Creating a sustainable network in biological and retrospective dosimetry that involves a large number of experienced laboratories throughout the European Union (EU) will significantly improve the accident and emergency response capabilities in case of a large-scale radiological emergency. A well-organised cooperative action involving EU laboratories will offer the best chance for fast and trustworthy dose assessments that are urgently needed in an emergency situation. To this end, the EC supports the establishment of a European network in biological dosimetry (RENEB). The RENEB project started in January 2012 involving cooperation of 23 organisations from 16 European countries. The purpose of RENEB is to increase the biodosimetry capacities in case of large-scale radiological emergency scenarios. The progress of the project since its inception is presented, comprising the consolidation process of the network with its operational platform, intercomparison exercises, training activities, proceedings in quality assurance and horizon scanning for new methods and partners. Additionally, the benefit of the network for the radiation research community as a whole is addressed.
Collapse
|
13
|
OC-0085: Mitochondrial DNA variation as a biomarker for the development of radiation-induced lung toxicity. Radiother Oncol 2015. [DOI: 10.1016/s0167-8140(15)40085-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
14
|
The REQUITE project: validating predictive models and biomarkers of radiotherapy toxicity to reduce side-effects and improve quality of life in cancer survivors. Clin Oncol (R Coll Radiol) 2014; 26:739-42. [PMID: 25267305 DOI: 10.1016/j.clon.2014.09.008] [Citation(s) in RCA: 63] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2014] [Accepted: 09/04/2014] [Indexed: 12/25/2022]
|
15
|
γ-H2AX foci as in vivo effect biomarker in children emphasize the importance to minimize x-ray doses in paediatric CT imaging. Eur Radiol 2014; 25:800-11. [PMID: 25354556 PMCID: PMC4328121 DOI: 10.1007/s00330-014-3463-8] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2014] [Revised: 09/16/2014] [Accepted: 10/01/2014] [Indexed: 11/26/2022]
Abstract
Objectives Investigation of DNA damage induced by CT x-rays in paediatric patients versus patient dose in a multicentre setting. Methods From 51 paediatric patients (median age, 3.8 years) who underwent an abdomen or chest CT examination in one of the five participating radiology departments, blood samples were taken before and shortly after the examination. DNA damage was estimated by scoring γ-H2AX foci in peripheral blood T lymphocytes. Patient-specific organ and tissue doses were calculated with a validated Monte Carlo program. Individual lifetime attributable risks (LAR) for cancer incidence and mortality were estimated according to the BEIR VII risk models. Results Despite the low CT doses, a median increase of 0.13 γ-H2AX foci/cell was observed. Plotting the induced γ-H2AX foci versus blood dose indicated a low-dose hypersensitivity, supported also by an in vitro dose–response study. Differences in dose levels between radiology centres were reflected in differences in DNA damage. LAR of cancer mortality for the paediatric chest CT and abdomen CT cohort was 0.08 and 0.13 ‰ respectively. Conclusion CT x-rays induce DNA damage in paediatric patients even at low doses and the level of DNA damage is reduced by application of more effective CT dose reduction techniques and paediatric protocols. Key Points • CT induces a small, significant number of double-strand DNA breaks in children. • More effective CT dose reduction results in less DNA damage. • Risk estimates based on the LNT hypothesis may represent underestimates.
Collapse
|
16
|
Is a semi-automated approach indicated in the application of the automated micronucleus assay for triage purposes? RADIATION PROTECTION DOSIMETRY 2014; 159:87-94. [PMID: 24743767 DOI: 10.1093/rpd/ncu130] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Within the EU MULTIBIODOSE project, the automated micronucleus (MN) assay was optimised for population triage in large-scale radiological emergencies. For MN scoring, two approaches were applied using the Metafer4 platform (MetaSystems, Germany): fully automated scoring and semi-automated scoring with visual inspection of the gallery of MN-positive objects. Dose-response curves were established for acute and protracted whole-body and partial-body exposures. A database of background MN yields was set up, allowing determination of the dose detection threshold in both scoring modes. An analysis of the overdispersion of the MN frequency distribution σ(2)/µ obtained by semi-automated scoring showed that the value of this parameter represents a reliability check of the calculated equivalent total body dose in case the accident overexposure is a partial-body exposure. The elaborated methodology was validated in an accident training exercise. Overall, the semi-automated scoring procedure represents important added value to the automated MN assay.
Collapse
|
17
|
Validation of semi-automatic scoring of dicentric chromosomes after simulation of three different irradiation scenarios. HEALTH PHYSICS 2014; 106:764-771. [PMID: 24776911 DOI: 10.1097/hp.0000000000000077] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Large scale radiological emergencies require high throughput techniques of biological dosimetry for population triage in order to identify individuals indicated for medical treatment. The dicentric assay is the "gold standard" technique for the performance of biological dosimetry, but it is very time consuming and needs well trained scorers. To increase the throughput of blood samples, semi-automation of dicentric scoring was investigated in the framework of the MULTIBIODOSE EU FP7 project, and dose effect curves were established in six biodosimetry laboratories. To validate these dose effect curves, blood samples from 33 healthy donors (>10 donors/scenario) were irradiated in vitro with ⁶⁰Co gamma rays simulating three different exposure scenarios: acute whole body, partial body, and protracted exposure, with three different doses for each scenario. All the blood samples were irradiated at Ghent University, Belgium, and then shipped blind coded to the participating laboratories. The blood samples were set up by each lab using their own standard protocols, and metaphase slides were prepared to validate the calibration curves established by semi-automatic dicentric scoring. In order to achieve this, 300 metaphases per sample were captured, and the doses were estimated using the newly formed dose effect curves. After acute uniform exposure, all laboratories were able to distinguish between 0 Gy, 0.5 Gy, 2.0, and 4.0 Gy (p < 0.001), and, in most cases, the dose estimates were within a range of ± 0.5 Gy of the given dose. After protracted exposure, all laboratories were able to distinguish between 1.0 Gy, 2.0 Gy, and 4.0 Gy (p < 0.001), and here also a large number of the dose estimates were within ± 0.5 Gy of the irradiation dose. After simulated partial body exposure, all laboratories were able to distinguish between 2.0 Gy, 4.0 Gy, and 6.0 Gy (p < 0.001). Overdispersion of the dicentric distribution enabled the detection of the partial body samples; however, this result was clearly dose-dependent. For partial body exposures, only a few dose estimates were in the range of ± 0.5 Gy of the given dose, but an improvement could be achieved with higher cell numbers. The new method of semi-automation of the dicentric assay was introduced successfully in a network of six laboratories. It is therefore concluded that this method can be used as a high-throughput screening tool in a large-scale radiation accident.
Collapse
|
18
|
Web-based scoring of the dicentric assay, a collaborative biodosimetric scoring strategy for population triage in large scale radiation accidents. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2014; 53:241-254. [PMID: 24557539 DOI: 10.1007/s00411-014-0519-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2013] [Accepted: 01/28/2014] [Indexed: 06/03/2023]
Abstract
In the case of a large scale radiation accident high throughput methods of biological dosimetry for population triage are needed to identify individuals requiring clinical treatment. The dicentric assay performed in web-based scoring mode may be a very suitable technique. Within the MULTIBIODOSE EU FP7 project a network is being established of 8 laboratories with expertise in dose estimations based on the dicentric assay. Here, the manual dicentric assay was tested in a web-based scoring mode. More than 23,000 high resolution images of metaphase spreads (only first mitosis) were captured by four laboratories and established as image galleries on the internet (cloud). The galleries included images of a complete dose effect curve (0-5.0 Gy) and three types of irradiation scenarios simulating acute whole body, partial body and protracted exposure. The blood samples had been irradiated in vitro with gamma rays at the University of Ghent, Belgium. Two laboratories provided image galleries from Fluorescence plus Giemsa stained slides (3 h colcemid) and the image galleries from the other two laboratories contained images from Giemsa stained preparations (24 h colcemid). Each of the 8 participating laboratories analysed 3 dose points of the dose effect curve (scoring 100 cells for each point) and 3 unknown dose points (50 cells) for each of the 3 simulated irradiation scenarios. At first all analyses were performed in a QuickScan Mode without scoring individual chromosomes, followed by conventional scoring (only complete cells, 46 centromeres). The calibration curves obtained using these two scoring methods were very similar, with no significant difference in the linear-quadratic curve coefficients. Analysis of variance showed a significant effect of dose on the yield of dicentrics, but no significant effect of the laboratories, different methods of slide preparation or different incubation times used for colcemid. The results obtained to date within the MULTIBIODOSE project by a network of 8 collaborating laboratories throughout Europe are very promising. The dicentric assay in the web based scoring mode as a high throughput scoring strategy is a useful application for biodosimetry in the case of a large scale radiation accident.
Collapse
|
19
|
|
20
|
Automatic scoring of dicentric chromosomes as a tool in large scale radiation accidents. MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS 2013; 756:174-83. [DOI: 10.1016/j.mrgentox.2013.05.013] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2013] [Accepted: 05/07/2013] [Indexed: 11/27/2022]
|
21
|
Abstract
Rapid biodosimetry tools are required to assist with triage in the case of a large-scale radiation incident. Here, we aimed to determine the dose-assessment accuracy of the well-established dicentric chromosome assay (DCA) and cytokinesis-block micronucleus assay (CBMN) in comparison to the emerging γ-H2AX foci and gene expression assays for triage mode biodosimetry and radiation injury assessment. Coded blood samples exposed to 10 X-ray doses (240 kVp, 1 Gy/min) of up to 6.4 Gy were sent to participants for dose estimation. Report times were documented for each laboratory and assay. The mean absolute difference (MAD) of estimated doses relative to the true doses was calculated. We also merged doses into binary dose categories of clinical relevance and examined accuracy, sensitivity and specificity of the assays. Dose estimates were reported by the first laboratories within 0.3-0.4 days of receipt of samples for the γ-H2AX and gene expression assays compared to 2.4 and 4 days for the DCA and CBMN assays, respectively. Irrespective of the assay we found a 2.5-4-fold variation of interlaboratory accuracy per assay and lowest MAD values for the DCA assay (0.16 Gy) followed by CBMN (0.34 Gy), gene expression (0.34 Gy) and γ-H2AX (0.45 Gy) foci assay. Binary categories of dose estimates could be discriminated with equal efficiency for all assays, but at doses ≥1.5 Gy a 10% decrease in efficiency was observed for the foci assay, which was still comparable to the CBMN assay. In conclusion, the DCA has been confirmed as the gold standard biodosimetry method, but in situations where speed and throughput are more important than ultimate accuracy, the emerging rapid molecular assays have the potential to become useful triage tools.
Collapse
|
22
|
PO-0903: Prediction of radiation-induced toxicity in prostate cancer patients: biomarker models for nocturia and hematuria. Radiother Oncol 2013. [DOI: 10.1016/s0167-8140(15)33209-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
23
|
Realising the European Network of Biodosimetry (RENEB). RADIATION PROTECTION DOSIMETRY 2012; 151:621-625. [PMID: 22923244 DOI: 10.1093/rpd/ncs157] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
In Europe, a network for biological dosimetry has been created to strengthen the emergency preparedness and response capabilities in case of a large-scale nuclear accident or radiological emergency. Through the RENEB (Realising the European Network of Biodosimetry) project, 23 experienced laboratories from 16 European countries will establish a sustainable network for rapid, comprehensive and standardised biodosimetry provision that would be urgently required in an emergency situation on European ground. The foundation of the network is formed by five main pillars: (1) the ad hoc operational basis, (2) a basis of future developments, (3) an effective quality-management system, (4) arrangements to guarantee long-term sustainability and (5) awareness of the existence of RENEB. RENEB will thus provide a mechanism for quick, efficient and reliable support within the European radiation emergency management. The scientific basis of RENEB will concurrently contribute to increased safety in the field of radiation protection.
Collapse
|
24
|
Platelet gel supernatant as a potential tool to repopulate acellular heart valves. Cell Prolif 2012; 45:378-85. [PMID: 22691137 DOI: 10.1111/j.1365-2184.2012.00830.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2012] [Accepted: 04/03/2012] [Indexed: 11/28/2022] Open
Abstract
OBJECTIVE The aim of this study was to repopulate decellularized heart valve matrices with ovine mesenchymal stem cells (oMSCs) by the use of platelet gel (PG) supernatant, a storage vehicle for growth factors. METHODS oMSCs were exposed to different concentrations of PG-released supernatant and cell proliferation was evaluated using the MTS assay. oMSC motility and invasiveness were assayed using a Boyden chamber. A quantitative sandwich enzyme immunoassay was used to examine amounts of bFGF and TGF-β1 in the PG supernatant. Repopulation of acellular heart valve matrices was stimulated by seeding matrices with oMSCs supplemented with the PG supernatant. RESULTS The most significant increase in proliferation induced by PG supernatant appeared at 1 × 10(5) plts/ml concentration. Higher concentrations evoked reduction of the stimulatory process. oMSC motility was most significantly stimulated at 1 × 10(6) plts/ml. Stimulating invasiveness of oMSCs needed the much higher concentration of 2 × 10(6) plts/ml. Immunoassays revealed that sheep PG supernatant contains 184.8 pg/ml bFGF and 60.5 ng/ml TGF-β1. Moreover, repopulation of acellular heart valve matrices was significantly enhanced by PG supernatant addition and resulted in upregulation of the myofibroblast marker alpha-smooth muscle actin. CONCLUSIONS Growth factors released from platelets had the potential to induce cell repopulation in a heart valve tissue engineering procedure, through stimulation of mesenchymal stem-cell migration and invasion.
Collapse
|
25
|
PD-0533 PRE-TREATMENT NOCTURIA, RADICAL PROSTATECTOMY AND TGFp1 SNPS ARE ASSOCIATED WITH RADIATION-INDUCED NOCTURIA. Radiother Oncol 2012. [DOI: 10.1016/s0167-8140(12)70872-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
26
|
OC-0505 A PREDICTIVE MODEL FOR DYSPHAGIA DURING IMRT IN HEAD AND NECK CANCER : INTRODUCTION OF THE EMLASSO TECHNIQUE. Radiother Oncol 2012. [DOI: 10.1016/s0167-8140(12)70844-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
27
|
Combined effect of polymorphisms in Rad51 and Xrcc3 on breast cancer risk and chromosomal radiosensitivity. Mol Med Rep 2011; 4:901-12. [PMID: 21725594 DOI: 10.3892/mmr.2011.523] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2011] [Accepted: 06/02/2011] [Indexed: 11/06/2022] Open
Abstract
Enhanced in vitro chromosomal radiosensitivity (CRS) has been proposed as a marker for low-penetrance gene mutations predisposing to breast cancer (BC). Since the double strand break (DSB) is the most detrimental form of DNA damage induced by ionizing radiation, it is possible that mutations in genes encoding proteins involved in DSB repair affect breast cancer risk. The purpose of the present study was to examine whether five single nucleotide polymorphisms (SNPs) in Rad51 and Xrcc3 (rs1801320, rs1801321, rs1799796, rs861539 and rs1799794) exhibited an association with breast cancer susceptibility in a Belgian population of BC patients with a known or putative genetic predisposition. We also ascertained whether a relationship exists between the occurrence of the variant alleles of these variations and in vitro CRS. Blood samples were obtained from BC patients and from the control population that included healthy female individuals. Variations in the 5' UTR of Rad51 and Xrcc3 were genotyped, and statistical analysis was performed. The results showed that low-penetrant variations in Rad51 and Xrcc3, two proteins belonging to the homologous recombination DSB repair pathway, may modify BC risk in patients already carrying a pathological mutation in the highly penetrant BC genes BRCA1 and BRCA2. Combined risk genotype analysis revealed that Rad51 SNPs enhance BC risk in BRCA2 patients, whereas Xrcc3 SNPs significantly enhance BC risk in carriers of BRCA1 mutations and in patients with hereditary BC. When four putative risk genotypes of Rad51 and Xrcc3 were combined, positive significant odds ratios were obtained in the entire patient population and in patients with a hereditary history of disease. Although obtained from a limited number of patients, our data are supportive of a polygenic model whereby combinations of weak variations are responsible for an enhanced BC risk by acting jointly with high-penetrant mutations in BRCA1 or BRCA2.
Collapse
|
28
|
OPTIMISATION OF A MULTI-COMPONENT PREDICTION MODEL FOR SEVERE ACUTE DYSPHAGIA FOR IMRT TREATED HEAD AND NECK CANCER PATIENTS. Radiother Oncol 2011. [DOI: 10.1016/s0167-8140(11)71780-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
29
|
Does digital flat detector technology tip the scale towards better image quality or reduced patient dose in interventional cardiology? Eur J Radiol 2009; 72:348-53. [DOI: 10.1016/j.ejrad.2008.07.028] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2008] [Accepted: 07/28/2008] [Indexed: 11/28/2022]
|
30
|
Genetic Susceptibility in Solvent Induced Neurobehavioral Effects. Neurotox Res 2009; 17:268-78. [DOI: 10.1007/s12640-009-9100-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2009] [Revised: 08/04/2009] [Accepted: 08/12/2009] [Indexed: 10/20/2022]
|
31
|
Dose response relationships for chromosome aberrations induced by low doses of alpha-particle radiation. RADIATION PROTECTION DOSIMETRY 2009; 135:268-271. [PMID: 19622542 DOI: 10.1093/rpd/ncp116] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Using a single colour fluorescence in situ hybridisation technique, dose-responses were derived for a range of chromosomally aberrant cell types and categories of aberrations induced in peripheral blood lymphocytes by alpha-particle radiation and analysed in their first in vitro division. For a range of doses that resulted predominantly in targeted cells receiving a single hit, i.e. 0-200 mGy, linear models fitted all the different categories of aberrant cells and aberration types but the profile of chromosome damage differed for 500 mGy, reflecting the effect of different track structure.
Collapse
|
32
|
Characterization of the c.190T>C missense mutation in BRCA1 codon 64 (Cys64Arg). Int J Oncol 2009; 34:1005-15. [PMID: 19287957 DOI: 10.3892/ijo_00000226] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
In the Milan area (Northern Italy), we identified a family characterized by a high prevalence of ovarian and breast cancer cases (5 out of 6 subjects, over 3 generations), and a predominant prevalence of ovarian lesions (4 out of 5 patients). Analysis of BRCA1 and BRCA2 genes allowed the identification of the missense c.190T>C mutation in codon 64 (Cys64Arg) of BRCA1. The aims of the present investigation were to characterize the functional implications of the c.190T>C mutation at the molecular level, and to search whether additional polymorphisms might be linked to the peculiar phenotypic features observed in the Italian pedigree. Molecular modelling studies suggested that substitution of the cysteine 64 with an arginine likely disrupts the architecture of the BRCA1 RING finger domain, responsible for the interaction with BARD1, essential for the tumor-suppressor activity of the BRCA1-BARD1 complex. By splicing site information analysis, exonic splicing enhancer site characterization, and analysis of transcript fragment length and sequence, we showed that the c.190T>C mutation was able to modulate the splicing of exon 5 in a fashion opposite to the c.190T>G transversion, responsible for the functionally-related Cys64Gly amino acid substitution. Genotyping of BRCA1 and BRCA2 in the Italian family revealed the presence of two significant polymorphisms: the cancer-associated c.2612C>T SNP in BRCA1, and the c.-26G>A SNP in the BRCA2 gene, acting as an ovarian cancer risk modifier in carriers of deleterious BRCA1 mutations. Analysis of these SNPs in a genotypically-unrelated Polish family, characterized by prevalent breast neoplasms in carriers of the c.190T>C mutation, revealed a genetic profile consistent with the hypothetic role of both polymorphisms.
Collapse
|
33
|
Study of Dose-rate and Split-dose Effects on thein VitroMicronucleus Yield in Human Lymphocytes Exposed to X-rays. Int J Radiat Biol 2009; 61:777-84. [PMID: 1351527 DOI: 10.1080/09553009214551641] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
This paper reports the effects of changes in dose-rate and dose-fractionation on the micronucleus (MN) yield in human lymphocytes exposed to 250 kV X-rays. For the investigation of dose-rate effects whole blood samples of four healthy donors were irradiated with doses ranging from 1 to 4 Gy given at various dose-rates between 0.2 and 40 Gy/h. For the higher doses (3 and 4 Gy) a decline in the MN yield became apparent when the dose-rate was reduced below 1.6 Gy/h. This effect was enhanced systematically by a further lowering of the dose-rate. For lower doses (1 and 2 Gy) the reduction in the MN yield was less pronounced: only a small effect was observed for two donors when a dose of 2 Gy was administered at a dose-rate of 0.2 Gy/h. In the split-dose experiment a dose of 4 Gy was delivered either as a single exposure or in two fractions of 2 Gy, separated by time intervals ranging from 30 min to 10 h. A continuous decrease of the MN yield with increasing interfraction time is observed: after an initial fast decline a further slight reduction in the MN yield occurs. The observed dose-rate and split-dose effects on the MN yield can be attributed to repair of sublethal damage.
Collapse
|
34
|
The influence of small field sizes, penumbra, spot size and measurement depth on perturbation factors for microionization chambers. Phys Med Biol 2009; 54:2951-69. [DOI: 10.1088/0031-9155/54/9/024] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
35
|
A large-scale multicentre study of patient skin doses in interventional cardiology: dose-area product action levels and dose reference levels. Br J Radiol 2009; 82:303-12. [PMID: 19124567 DOI: 10.1259/bjr/29449648] [Citation(s) in RCA: 66] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
For 318 patients in 8 different Belgian hospitals, the entire skin-dose distribution was mapped using a grid of 70 thermoluminescence dosimeters per patient, allowing an accurate determination of the maximum skin dose (MSD). Dose-area product (DAP) values, exposure parameters and geometry, together with procedure, patient and cardiologist characteristics, were also registered. Procedures were divided into two groups: diagnostic procedures (coronary angiography) and therapeutic procedures (dilatation, stent, combined procedures (e.g. coronary angiography + dilatation + stent)). The mean value of the MSD was 0.310 Gy for diagnostic and 0.699 Gy for therapeutic procedures. The most critical projection for receiving the MSD is the LAO90 (left anterior oblique) geometry. In 3% of cases, the MSD exceeded the 2 Gy dose threshold for deterministic effects. Action levels in terms of DAP values as the basis for a strategy for follow-up of patients for deterministic radiation skin effects were derived from measured MSD and cumulative DAP values. Two DAP action levels are proposed. A first DAP action level of 125 Gy cm(2) corresponding to the dose threshold of 2 Gy would imply an optional radiopathological follow-up depending on the cardiologist's decision. A second DAP action level of 250 Gy cm(2) corresponding to the 3 Gy skin dose would imply a systematic follow-up. Dose reference levels - 71.3 Gy cm(2) for diagnostic and 106.0 Gy cm(2) for therapeutic procedures - were derived from the 75 percentile of the DAP distributions. As a conclusion, we propose that total DAP is registered in patient's record file, as it can serve to improve the follow-up of patients for radiation-induced skin injuries.
Collapse
|
36
|
An organotypical in vitro model for vascular tissue remodelling and its application to study radiation effects. Cytotechnology 2008; 34:185-95. [PMID: 19003394 DOI: 10.1023/a:1008168930905] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
An organotypic in vitro model, to study vascular tissueremodeling, was evaluated as a function of culture period. Inorder to validate the model as a tool for studying vascularresponses to damage, a dose-response analysis to ionizingirradiation was included.Rat aortic rings were explanted in vitro after being irradiatedwith single doses of (60)Co gamma-rays, namely 0, 5, 10, 15, 20or 25 Gy. Irradiated and sham-irradiated aortic rings werecultured for 3 weeks. Explant outgrowth on an adhesivesubstrate was evaluated by macroscopical scoring, and ringsderived from each irradiation group together with theoutgrowths were fixed and embedded in paraffin after 2, 7, 14and 21 days. Bromodeoxyuridine incorporation, alpha smoothmuscle actin and collagen types I and III were scored onimmunohistochemically stained sections. For each studiedparameter, irradiated and sham-irradiated rings were compared.In cultures of sham-irradiated rings, alterations from acontractile towards a synthetic/migratory smooth muscle cellphenotype were confirmed. After 3 weeks, fullgrown cultures hadformed. Irradiation slowed down the phenotypical modifications.After 15 Gy, irradiation explant outgrowth was already retarded;after 25 Gy, the outgrowth was completely blocked. On the otherhand, a dose of 15 Gy or more induced an increased collagen Iproduction in the tunica media.In conclusion, the present organotypical in vitro model fits toanalyse dynamics in the original vascular tissues as well as inthe primary outgrowth. It enables to confirm features oftissular reorganization and effects of ionizing radiationdescribed in vivo.
Collapse
|
37
|
On the calibration process of film dosimetry: OLS inverse regression versus WLS inverse prediction. Phys Med Biol 2008; 53:3971-84. [DOI: 10.1088/0031-9155/53/14/015] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
38
|
Chromosomal radiosensitivity in head and neck cancer patients: evidence for genetic predisposition? Br J Cancer 2008; 98:1723-38. [PMID: 18414410 PMCID: PMC2391130 DOI: 10.1038/sj.bjc.6604345] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
The association between chromosomal radiosensitivity and genetic predisposition to head and neck cancer was investigated in this study. In all, 101 head and neck cancer patients and 75 healthy control individuals were included in the study. The G(2) assay was used to measure chromosomal radiosensitivity. The results demonstrated that head and neck cancer patients had a statistically higher number of radiation-induced chromatid breaks than controls, with mean values of 1.23 and 1.10 breaks per cell, respectively (P<0.001). Using the 90th percentile of the G(2) scores of the healthy individuals as a cutoff value for chromosomal radiosensitivity, 26% of the cancer patients were radiosensitive compared with 9% of the healthy controls (P=0.008). The mean number of radiation-induced chromatid breaks and the proportion of radiosensitive individuals were highest for oral cavity cancer patients (1.26 breaks per cell, 38%) and pharynx cancer patients (1.27 breaks per cell, 35%). The difference between patients and controls was most pronounced in the lower age group (<or=50 years, 1.32 breaks per cell, 38%) and in the non- and light smoking patient group (<or=10 pack-years, 1.28 breaks per cell, 46%). In conclusion, enhanced chromosomal radiosensitivity is a marker of genetic predisposition to head and neck cancer, and the genetic contribution is highest for oral cavity and pharynx cancer patients and for early onset and non- and light smoking patients.
Collapse
|
39
|
Interventional cardiovascular procedures in Belgium: effective dose and conversion factors. RADIATION PROTECTION DOSIMETRY 2008; 129:77-82. [PMID: 18385181 DOI: 10.1093/rpd/ncn021] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Effective dose (E), representing the risk of late radiation-induced effects, can be estimated by the use of conversion factors (CF), converting direct measurable quantities such as dose-area-product into E. Eight Belgian hospitals participated in the study with a total number of 318 procedures. E-values, calculated with PCXMC, were compared for the different hospitals for diagnostic and therapeutic procedures separately. E-values varied significantly depending on the hospital where the procedure was performed (P < 0.001), on filtration insertion (P < 0.001), on whether a centre is a training centre or not, the dose conscious action of the cardiologists and the complexity of the procedure (P < 0.001). Hospital-specific CF were calculated. An average CF of 0.185 mSv Gycm(-2) was obtained with a satisfactory correlation (r = 0.966, P < 0.001). The differences in CF between hospitals were due to, a large extent, the availability of additional filtration in cinegraphy mode (P < 0.001) and not to the differences in irradiation geometries in the clinical protocol of the interventional procedures.
Collapse
|
40
|
A large-scale multicentre study in Belgium of dose area product values and effective doses in interventional cardiology using contemporary X-ray equipment. RADIATION PROTECTION DOSIMETRY 2008; 128:312-23. [PMID: 17681964 DOI: 10.1093/rpd/ncm379] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
In this paper, a large-scale multicentre patient dose study performed in eight Belgian interventional cardiology departments is presented. Effective dose (E) was calculated based on a detailed dose-area product (DAP)-registration during each procedure and by using conversion coefficients generated by the Monte Carlo-based computer program PCXMC. Conversion coefficients were found to be 0.177 mSv Gycm(-2) for systems that do not use any additional copper filtration in cineradiography and 0.207 mSv Gycm(-2) for systems that use additional copper filtration in cineradiography. Mean E values of 9.6 and 15.3 mSv for diagnostic and therapeutic procedures, respectively, were obtained. DAP distributions were investigated in order to derive dose reference levels: 71 and 106 Gycm2 for diagnostic and therapeutic procedures, respectively, are proposed. Significant differences were observed in DAP distributions taking into account whether additional copper filtration was used in the cineradiography mode. Apart from the skin, the organs most at risk are lungs and heart. The probability of fatal cancer for the studied population amounted to 1.1x10(-4) and 2.1x10(-4) for diagnostic and therapeutic procedures, respectively, for the age distribution of the patients considered in this multicentre study.
Collapse
|
41
|
Monte Carlo modeling of the ModuLeaf miniature MLC for small field dosimetry and quality assurance of the clinical treatment planning system. Phys Med Biol 2007; 52:3275-90. [PMID: 17505102 DOI: 10.1088/0031-9155/52/11/022] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The purpose of this investigation was the verification of both the measured data and quality of the implementation of the add-on ModuLeaf miniature multileaf collimator (ML mMLC) into the clinical treatment planning system for conformal stereotactic radiosurgery treatment. To this end the treatment head with ML mMLC was modeled in the BEAMnrc Monte Carlo (MC) code. The 6 MV photon beams used in the setup were first benchmarked with a set of measurements. A total ML mMLC transmission of 1.13% of the 10 x 10 cm2 open field dose was measured and reproduced with the BEAMnrc/DOSXYZnrc code. Correspondence between calculated and measured output factors (OFs) was within 2%. Correspondence between MC and measured profiles was within 2% dose and 2 mm distance, only for the smallest 0.5 x 0.5 cm2 field the results were within 3% dose. In the next step, the MC model was compared with Gafchromic film measurements and Pinnacle(3) 7.4 f (convolution superposition algorithm) calculated dose distributions, using a gamma evaluation comparison, for a multi-beam patient setup delivered to a Lucytrade mark phantom. The gamma evaluation of the MC versus Gafchromic film resulted in 3.4% of points not fulfilling gamma <or= 1 for a 2%/2 mm criterion, the Pinnacle(3) 7.4 f versus Gafchromic results 3.8% and Pinnacle versus MC less than 1%. For specific patients with lesions of 8 cc and 0.2 cc, Monte Carlo and Pinnacle simulations of the plans were performed and compared using DVH evaluation. DVHs corresponded within 2% dose and 2% volume.
Collapse
|
42
|
Typetesting of physical characteristics of digital mammography systems: first experiences within the Flemish breast cancer screening programme. JBR-BTR : ORGANE DE LA SOCIETE ROYALE BELGE DE RADIOLOGIE (SRBR) = ORGAAN VAN DE KONINKLIJKE BELGISCHE VERENIGING VOOR RADIOLOGIE (KBVR) 2007; 90:159-62. [PMID: 17696080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
To avoid the purchase of a digital mammography system by radiologists with intrinsic characteristics not able to fulfil the physical-technical quality requirements of the acceptance tests of the European guidance document, typetesting of digital equipment was introduced in the organisation and legislation of the Flemish breast cancer screening programme. Typetesting is performed for two types of instrumentation: systems for image capture and -processing and systems for image presentation. Typetesting is finalised or ongoing for eight DR systems and four CR systems. Eight workstations were or are submitted to the typetesting for image presentation. Experiences gained in typetesting of systems for image capture and -processing up to now show that the contrast-detail analysis of CDMAM phantom imaging and the homogeneity tests are most stringent. In general DR performs better than CR in imaging performance. Typetesting for image presentation has shown no difference in quality between CRT and LCD monitors. Furthermore, 3 MP monitors also pass the tests. However, to get the full resolution capabilities of the image capture system zooming in and scrolling over the image is necessary, which is time-consuming in clinical practice. Finally, we emphasize that typetesting involves also an evaluation of a set of clinical images by the working party of radiologists and that succeeding in typetesting does not mean that a particular system passes automatically the acceptance testing. A perfect tuning of the system and the coupling to a high quality X-ray system is necessary as well.
Collapse
|
43
|
Denoising of Monte Carlo dose calculations: smoothing capabilities versus introduction of systematic bias. Med Phys 2006; 33:1678-87. [PMID: 16872075 DOI: 10.1118/1.2198188] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
In order to evaluate the performance of denoising algorithms applied to Monte Carlo calculated dose distributions, conventional evaluation methods (rms difference, 1% and 2% difference) can be used. However, it is illustrated that these evaluation methods sometimes underestimate the introduction of bias, since possible bias effects are averaged out over the complete dose distribution. In the present work, a new evaluation method is introduced based on a sliding window superimposed on a difference dose distribution (reference dose-noisy/denoised dose). To illustrate its importance, a new denoising technique (ANRT) is presented based upon a combination of the principles of bilateral filtering and Savitzky-Golay filters. This technique is very conservative in order to limit the introduction of bias in high dose gradient regions. ANRT is compared with IRON for three challenging cases, namely an electron and photon beam impinging on heterogeneous phantoms and two IMRT treatment plans of head-and-neck cancer patients to determine the clinical relevance of the obtained results. For the electron beam case, IRON outperforms ANRT concerning the smoothing capabilities, while no differences in systematic bias are observed. However, for the photon beam case, although ANRT and IRON perform equally well on the conventional evaluation tests (rms difference, 1% and 2% difference), IRON clearly introduces much more bias in the penumbral regions while ANRT seems to introduce no bias at all. When applied to the IMRT patient cases, both denoising methods perform equally well regarding smoothing and bias introduction. This is probably caused by the summation of a large set of different beam segments, decreasing dose gradients compared to a single beam. A reduction in calculation time without introducing large systematic bias can shorten a Monte Carlo treatment planning process considerably and is therefore very useful for the initial trial and error phase of the treatment planning process.
Collapse
|
44
|
Decoupling initial electron beam parameters for Monte Carlo photon beam modelling by removing beam-modifying filters from the beam path. Phys Med Biol 2005; 50:5935-51. [PMID: 16333165 DOI: 10.1088/0031-9155/50/24/012] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A new method is presented to decouple the parameters of the incident e(-) beam hitting the target of the linear accelerator, which consists essentially in optimizing the agreement between measurements and calculations when the difference filter, which is an additional filter inserted in the linac head to obtain uniform lateral dose-profile curves for the high energy photon beam, and flattening filter are removed from the beam path. This leads to lateral dose-profile curves, which depend only on the mean energy of the incident electron beam, since the effect of the radial intensity distribution of the incident e- beam is negligible when both filters are absent. The location of the primary collimator and the thickness and density of the target are not considered as adjustable parameters, since a satisfactory working Monte Carlo model is obtained for the low energy photon beam (6 MV) of the linac using the same target and primary collimator. This method was applied to conclude that the mean energy of the incident e- beam for the high energy photon beam (18 MV) of our Elekta SLi Plus linac is equal to 14.9 MeV. After optimizing the mean energy, the modelling of the filters, in accordance with the information provided by the manufacturer, can be verified by positioning only one filter in the linac head while the other is removed. It is also demonstrated that the parameter setting for Bremsstrahlung angular sampling in BEAMnrc ('Simple' using the leading term of the Koch and Motz equation or 'KM' using the full equation) leads to different dose-profile curves for the same incident electron energy for the studied 18 MV beam. It is therefore important to perform the calculations in 'KM' mode. Note that both filters are not physically removed from the linac head. All filters remain present in the linac head and are only rotated out of the beam. This makes the described method applicable for practical usage since no recommissioning process is required.
Collapse
|
45
|
Microsatellite polymorphisms in DNA repair genes XRCC1, XRCC3 and XRCC5 in patients with gynecological tumors: association with late clinical radiosensitivity and cancer incidence. Radiat Res 2005; 164:237-44. [PMID: 16137195 DOI: 10.1667/rr3417.1] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
This study investigates the association of microsatellite polymorphisms in XRCC1, XRCC3 and XRCC5 with the development of late radiation-induced radiotherapy reactions and examines the correlation between these microsatellites and cancer incidence. Sixty-two women with cervical or endometrial cancer treated with radiotherapy were included in the study. According to the CTCAEv3.0 scale, 22 patients showed late adverse radiotherapy reactions (grade 2 or more). PCR on lymphocyte DNA followed by automated fragment analysis was performed to examine the number of tandem repeat units at each locus. No significant association was found between the repeat length at any of the microsatellites in XRCC1, XRCC3 or XRCC5 and the incidence of late radiotherapy complications. Since higher odds ratios (ORs) were found for the rare XRCC1 [AC]11 and [AC]21 repeats (OR = 2.65, P = 0.325 and OR = 8.67, P = 0.093, respectively), the possible involvement of these small and large repeats in clinical radiosensitivity cannot be completely ruled out. When specific numbers of repeats were examined, no significant correlation was found between the microsatellite repeat length in XRCC1 and XRCC5 and cancer incidence. A weak correlation between XRCC3 [AC]16 homozygotes and cancer incidence was found (OR = 2.56, P = 0.055). A large-scale multicenter study of cancer patients with a high number of radiosensitive individuals is needed to clarify the value of rare polymorphic microsatellite repeats in XRCC1 and XRCC3 as a biomarker of clinical radiosensitivity or increased cancer risk.
Collapse
|
46
|
Osteopontin and bone metabolism: a histology and scintigraphy study in rats. Int J Oral Maxillofac Surg 2005; 34:794-9. [PMID: 16157249 DOI: 10.1016/j.ijom.2005.04.013] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2003] [Revised: 02/23/2005] [Accepted: 04/13/2005] [Indexed: 11/25/2022]
Abstract
Osteopontin (OPN) is one of the major non-collagen proteins in extracellular bone matrix. To elucidate the function of OPN in bone metabolism, a cellular defect was created in parietal bone and tibia of 12 rats. In Group 1, the left defects were filled with OPN-coated hydroxyapatite (OPN-H). In Group 2, the right defects were filled with non-coated hydroxyapatite (N-H). In both groups, the contra lateral defects were used as control defects. In Group 3, OPN-H was inserted in the left defects and N-H in the right defects. Bone metabolism was measured by (45)Ca and technetium-99m methylene diphosphonate scintigraphy for 4 weeks. Scintigraphy did not show any significant differences in bone metabolism between the defects filled with OPN-H and N-H. A higher bone metabolism was measured between the parietal defects filled with OPN-H or N-H in comparison with the parietal control defects. This difference, however, was not significant and was less for tibia defects. Histological observation (7th week) shows less inflammatory cells at the tibia defects filled with OPN-H compared to the tibia defects filled with N-H. This study did not show any acceleration or inhibition of bone metabolism in parietal or tibia bone in rats, but there is some evidence that OPN might influence inflammatory cells in bone matrix.
Collapse
|
47
|
335 Optimization of the mean energy of the incident electron beam for MCTP by removing the beam-modifying filters from the linac head. Radiother Oncol 2005. [DOI: 10.1016/s0167-8140(05)81311-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
48
|
326 The effect of geometrical and scoring voxel dimensions on accuracy and efficacy of Monte Carlo dose calculations for IMRT. Radiother Oncol 2005. [DOI: 10.1016/s0167-8140(05)81302-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
49
|
Investigation of geometrical and scoring grid resolution for Monte Carlo dose calculations for IMRT. Phys Med Biol 2005; 50:4005-19. [PMID: 16177526 DOI: 10.1088/0031-9155/50/17/006] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Monte Carlo based treatment planning of two different patient groups treated with step-and-shoot IMRT (head-and-neck and lung treatments) with different CT resolutions and scoring methods is performed to determine the effect of geometrical and scoring voxel sizes on DVHs and calculation times. Dose scoring is performed in two different ways: directly into geometrical voxels (or in a number of grouped geometrical voxels) or into scoring voxels defined by a separate scoring grid superimposed on the geometrical grid. For the head-and-neck cancer patients, more than 2% difference is noted in the right optical nerve when using voxel dimensions of 4 x 4 x 4 mm3 compared to the reference calculation with 1 x 1 x 2 mm3 voxel dimensions. For the lung cancer patients, 2% difference is noted in the spinal cord when using voxel dimensions of 4 x 4 x 10 mm3 compared to the 1 x 1 x 5 mm3 calculation. An independent scoring grid introduces several advantages. In cases where a relatively high geometrical resolution is required and where the scoring resolution is less important, the number of scoring voxels can be limited while maintaining a high geometrical resolution. This can be achieved either by grouping several geometrical voxels together into scoring voxels or by superimposing a separate scoring grid of spherical voxels with a user-defined radius on the geometrical grid. For the studied lung cancer cases, both methods produce accurate results and introduce a speed increase by a factor of 10-36. In cases where a low geometrical resolution is allowed, but where a high scoring resolution is required, superimposing a separate scoring grid on the geometrical grid allows a reduction in geometrical voxels while maintaining a high scoring resolution. For the studied head-and-neck cancer cases, calculations performed with a geometrical resolution of 2 x 2 x 2 mm3 and a separate scoring grid containing spherical scoring voxels with a radius of 2 mm produce accurate results and introduce a speed increase by a factor of 13. The scoring grid provides an additional degree of freedom for limiting calculation time and memory requirements by selecting optimized scoring and geometrical voxel dimensions in an independent way.
Collapse
|
50
|
Abstract
PURPOSE The chromosomal radiosensitivity of a selected group of familial breast cancer patients carrying a mutation in BRCA1 (n=11) or BRCA2 (n=9) and a group of healthy mutation carriers (n=12) was investigated and compared to a reference group of breast cancer patients without a BRCA1/2 mutation (n=78) and a group of healthy women carrying no mutation (n=58). MATERIALS AND METHODS The chromosomal radiosensitivity was assessed with the G2 and the G0-micronucleus (MN)-assay on fresh blood samples and on Epstein-Barr virus (EBV)-transformed lymphoblastoid cell lines. For the MN-assay, lymphocytes were exposed in vitro to 3.5 Gy and 2 Gy 60Co gamma-rays at a high dose rate (HDR) or low dose rate (LDR). 70-h post-irradiation cultures were arrested and micronuclei were scored in 1000 binucleate cells. For the G2-assay lymphocytes were irradiated in vitro with a dose of 0.4 Gy 60Co gamma-rays after 71h incubation. Cultures were arrested 90 min after irradiation and chromatid breaks were scored in 50 metaphases. RESULTS The group of breast cancer patients with a BRCA1 or 2 mutation was on average more radiosensitive than the control group, but not different from breast cancer patients without a BRCA mutation. The radiation response of healthy BRCA1/2 carriers was not significantly different from the control group and also not different from relatives without a BRCA mutation. Comparing the radiation response in EBV cell lines derived from breast cancer patients with or without a BRCA1 mutation revealed no significant difference. CONCLUSIONS Our results reveal that chromosomal radiosensitivity observed in breast cancer patients heterozygous for BRCA1 or 2 mutations, could not be demonstrated in healthy BRCA1/2 mutation carriers. This suggests that mutations in BRCA1 or 2 genes are not playing a main role in chromosomal radiosensitivity, this although BRCA1 and 2 are both involved in DNA repair/signalling processes.
Collapse
|