Willers SM, Brunekreef B, Oldenwening M, Smit HA, Kerkhof M, Vries H. Gas cooking, kitchen ventilation, and exposure to combustion products. INDOOR AIR 2006; 16:65-73. [PMID: 16420499 DOI: 10.1111/j.1600-0668.2005.00404.x] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
We evaluated a questionnaire-based system for classifying homes into groups with distinctly different chances of accumulating combustion products from cooking appliances. The system was based on questions about type of cooking appliance, type and use of ventilation provisions, and kitchen size. Real-time measurements were made of CO, CO(2), temperature, and water vapor, and passive sampling was performed of nitrogen oxides, over a week-long period in 74 kitchens. During the measurements, inhabitants kept a diary to record appliance use time and use of ventilation provisions. The questionnaire-based and diary-based home classifications for the 'Chance of Accumulation of Combustion Products' (CACP) turned out to agree fairly well. For CO(2) as well as for CO a significant difference between the 'high' and 'low' CACP groups was found for the mean accumulation in the kitchen during cooking of the combustion generated concentrations. These facts are considered to be important experimental evidence of the CACP stratification being valid for our study population. In the homes studied, NO(2) as well as CO concentrations were found to be lower compared with previous studies in The Netherlands. Practical Implications Previous studies on indoor combustion product dispersal conducted in the early- to mid-1980s in the Netherlands showed much higher NO(2) and CO concentrations than the present study. Apparently, the removal of combustion products formed during cooking is more efficient in the (mostly newer) homes that we studied than in the homes studied in the early- to mid-1980s. More detailed knowledge of kitchen situations is needed to improve the CACP model. Future studies can achieve this by using questionnaires on the kitchen situation, diaries and real-time measurements of the combustion products under consideration.
Collapse
|
|
19 |
20 |
2
|
Heijnen L, de Vries HJ, van Pelt G, Stroobach E, Atsma A, Vranken J, De Maeyer K, Vissers L, Medema G. Qualitative detection of E. coli in distributed drinking water using real-time reverse transcription PCR targeting 16S rRNA: Validation and practical experiences. WATER RESEARCH 2024; 259:121843. [PMID: 38824794 DOI: 10.1016/j.watres.2024.121843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Revised: 05/17/2024] [Accepted: 05/27/2024] [Indexed: 06/04/2024]
Abstract
Escherichia coli (E. coli) plays a central role as an indicator for fecal contamination to predict the possible presence of microbial pathogens in drinking water. Current detection methods for E. coli are based on time-consuming culture-based techniques. There is a strong need for methods to detect fecal contamination rapidly in distributed drinking water to prevent outbreaks of waterborne disease and support water utilities to efficiently manage their operations like actions to repair or maintain distribution pipes, to minimize impact on consumers. This study describes the validation and application of a qualitative real time reverse transcription PCR (RT-PCR) method targeting 16S ribosomal RNA (rRNA) for rapid detection of E. coli in distributed drinking water. The RT-PCR assay targets 16S rRNA, a highly abundant RNA in viable cells, enabling robust detection at the required sensitivity of 1 CFU/100 ml. The validation was performed by comparing the RT-PCR method with the culture-based chromogenic reference method (CCA) using the protocol and criteria described in ISO 16,140-2:2016. The validation demonstrated that this RT-PCR method can be used to specifically detect E. coli in a broad range of drinking water samples with at least the same limit of detection as the culture method (Relative Limit Of Detection = 0.75, range 0.43-1.43). The inclusivity study showed that the RT-PCR method was able to detect a broad range of E. coli strains derived from different sources and geographic areas, including pathogenic serotype O157 strains that are not detected with the culture method. The exclusivity study determined that other bacterial genera are not detected with this RT-PCR. However, Escherichia fergusonii was detected and, based on "in silico" analysis, it is expected that also E. albertii and E. marmotae and Shigella species will be detectable using this RT-PCR. An interlaboratory study confirmed that the RT-PCR and culture method have comparable sensitivities when tested by different participants at different laboratories. The application of RT-PCR to confirm the hygienic quality of distributed drinking water after actions to repair or maintain distribution pipes was compared with the culture method on 8076 routine samples, analyzed by the drinking water laboratories in the Netherlands. This comparison study showed a 96.4 % agreement between RT-PCR and culture. In 3.3 % of the samples E. coli was detected with RT-PCR and not with the culture method and in 0.1 % of the samples E. coli was only detected by culture confirming either a higher sensitivity for RT-PCR or the detection of RNA from uncultivable cells. Finally, the application of RT-PCR was highlighted during a contamination event in Belgium where we demonstrate the potency of RT-PCR as a tool to rapidly monitor the spread of microbial contamination and to monitor the effect of measures to remove the contamination This is the first fully validated rapid nucleic based method for detection of E. coli in distributed drinking water. These results demonstrate that this RT-PCR method can be used as a rapid alternative to the culture method to monitor E. coli in distributed drinking water. However, it should be emphasized that nucleic acid based detection methods rely on highly different detection principles (detection of captured nucleic acids present in a sample) than culture base methods (presence of cells cultivable on a selective medium) resulting in occasional different analysis results. Varying treatment and disinfection steps (UV, chlorine, monochloramine, Ozone) or environmental factors (decay) can influence the results and cause differences between RT-PCR and culture methods.
Collapse
|
Validation Study |
1 |
|
3
|
Gómez L, Brandão J, Navarro A, Martines A, Sanseverino I, Porcel-Rodríguez E, Marinov D, Ableitner O, Allerberger F, Atsma A, Briancesco R, Cenov A, Cíchová M, Coccia AM, Della Libera S, De Maeyer K, Jan de Vries H, Elsinga G, Heijnen L, Hokajärvi AM, Janská V, Hrabar J, Huse-Kutowska M, Jozić S, Klatovsky S, Kornschober C, Kohls K, Krom A, Luden K, Mikula-Pratschke C, Pitkänen T, Poje M, Prokšová M, Retelj M, Rozwadowska B, Rytkönen A, Sarekoski A, Schlager S, Springer B, Stojan I, Stroobach E, Sučić N, Valério E, van Pelt G, Vranken J, Tomaš AV, Lušić DV, Włos E, Wubbels G, Ziombska M, Zelenik K, Ziuziakowski M, Lettieri T. Application of a real-time reverse transcription polymerase chain reaction for rapid detection of Escherichia coli in drinking water: an EU representative study. ENVIRONMENTAL RESEARCH 2025; 279:121786. [PMID: 40355062 DOI: 10.1016/j.envres.2025.121786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2025] [Revised: 04/30/2025] [Accepted: 05/04/2025] [Indexed: 05/14/2025]
Abstract
The microbiological quality of water intended for human consumption in the EU is regulated by the recast Drinking Water Directive 2020/2184 (DWD), which sets strict parametric values for intestinal enterococci and Escherichia coli (E. coli), allowing no more than zero colony-forming units per 100 mL. Detection and enumeration of E. coli typically rely on culture-based reference methods or the most probable number approach, which require 1-2 days to produce results-potentially delaying timely action during contamination events. In contrast, molecular techniques can deliver results within hours. The DWD permits the use of alternative methods if they are as reliable as the reference method and developing and validating such methods requires multiple laboratory trials in line with ISO standard 16140-2. Following this, we conducted a representative EU study to validate a molecular method based on real-time reverse transcription polymerase chain reaction for rapid E. coli detection in drinking water. In a concerted action, the first of its kind for drinking water, nineteen laboratories across ten Member States participated. To ensure consistency, drinking water was artificially contaminated with E. coli. The alternative method showed slightly lower sensitivity than the reference method (91.1 % vs. 97.2 %) but delivered much faster results, making it a valuable screening tool. It can support rapid decision-making during contamination events, reducing the risk of waterborne outbreaks and protecting public health. For reliable routine performance, appropriate training in this alternative method is strongly recommended.
Collapse
|
|
1 |
|