1
|
Hmaied F, Keskes S, Jebri S, Amri I, Yahya M, Loisy-Hamon F, Lebeau B, Hamdi M. Removal of Rotavirus and Bacteriophages by Membrane Bioreactor Technology from Sewage. Curr Microbiol 2015. [PMID: 26210901 DOI: 10.1007/s00284-015-0882-y] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Human enteric viruses constitute a public health concern due to their low infectious dose and their resistance to environmental factors and to inactivation processes. We aimed at assessing the performance of a laboratory scale Submerged membrane bioreactor (SMBR) treating abattoir wastewaters for Rotavirus (RV) and total coliphages removal. We also aimed at evaluating removal efficiency of enteric viruses through conventional activated sludge treatment by measuring concentrations of total coliphages, considered as fecal and viral contamination indicators, with double-layer agar technique. The Log10 reduction values of bacteriophages ranged from 1.06 to 1.47. Effluents were analyzed to investigate and quantify RV, hepatitis A virus (HAV), Hepatitis E virus (HEV), Noroviruses genogroup I (NoV GI) and genogroup II (NoVGII), and Enterovirus (EV) by real-time PCR, using standardized detection kits (ceeramTools detection kits(®)). All effluent samples were positive for RV; concentrations ranged from 5.2 × 10(5) to 1.3 × 10(7) genome copies/L. These results highlight the inefficiency of conventional biological process for viral removal. A complete removal of RV during Membrane Bioreactor treatment was obtained. To the best of our knowledge, this is the first study providing an evidence of removal of RV simultaneously with total coliphages by SMBR.
Collapse
|
Journal Article |
10 |
15 |
2
|
Ravichandran R, Binukumar JP, Al Amri I, Davis CA. Diamond detector in absorbed dose measurements in high-energy linear accelerator photon and electron beams. J Appl Clin Med Phys 2016; 17:291-303. [PMID: 27074452 PMCID: PMC5875569 DOI: 10.1120/jacmp.v17i2.5690] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2015] [Revised: 10/22/2015] [Accepted: 11/16/2015] [Indexed: 11/30/2022] Open
Abstract
Diamond detectors (DD) are preferred in small field dosimetry of radiation beams because of small dose profile penumbras, better spatial resolution, and tissue‐equivalent properties. We investigated a commercially available ‘microdiamond’ detector in realizing absorbed dose from first principles. A microdiamond detector, type TM 60019 with tandem electrometer is used to measure absorbed doses in water, nylon, and PMMA phantoms. With sensitive volume 0.004 mm3, radius 1.1 mm, thickness 1×10−3mm, the nominal response is 1 nC/Gy. It is assumed that the diamond detector could collect total electric charge (nC) developed during irradiation at 0 V bias. We found that dose rate effect is less than 0.7% for changing dose rate by 500 MU/min. The reproducibility in obtaining readings with diamond detector is found to be ±0.17% (1 SD) (n=11). The measured absorbed doses for 6 MV and 15 MV photons arrived at using mass energy absorption coefficients and stopping power ratios compared well with Nd, water calibrated ion chamber measured absorbed doses within 3% in water, PMMA, and nylon media. The calibration factor obtained for diamond detector confirmed response variation is due to sensitivity due to difference in manufacturing process. For electron beams, we had to apply ratio of electron densities of water to carbon. Our results qualify diamond dosimeter as a transfer standard, based on long‐term stability and reproducibility. Based on micro‐dimensions, we recommend these detectors for pretreatment dose verifications in small field irradiations like stereotactic treatments with image guidance. PACS number(s): 87.56.Da
Collapse
|
Journal Article |
9 |
13 |
3
|
Rosenthal E, Fougerou-Leurent C, Renault A, Carrieri MP, Marcellin F, Garraffo R, Teicher E, Aumaitre H, Lacombe K, Bailly F, Billaud E, Chevaliez S, Dominguez S, Valantin MA, Reynes J, Naqvi A, Cotte L, Metivier S, Leroy V, Dupon M, Allegre T, De Truchis P, Jeantils V, Chas J, Salmon-Ceron D, Morlat P, Neau D, Perré P, Piroth L, Pol S, Bourlière M, Pageaux GP, Alric L, Zucman D, Girard PM, Poizot-Martin I, Yazdanpanah Y, Raffi F, Pabic EL, Tual C, Pailhé A, Amri I, Bellissant E, Molina JM. Efficacy, safety and patient-reported outcomes of ledipasvir/sofosbuvir in NS3/4A protease inhibitor-experienced individuals with hepatitis C virus genotype 1 and HIV coinfection with and without cirrhosis (ANRS HC31 SOFTRIH study). HIV Med 2017; 19:227-237. [PMID: 29214737 DOI: 10.1111/hiv.12571] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/19/2017] [Indexed: 12/26/2022]
Abstract
OBJECTIVES Studies evaluating the efficacy and safety of the fixed-dose combination ledipasvir (LDV)/sofosbuvir (SOF) in patients coinfected with HIV-1 and hepatitis C virus (HCV) have mainly included treatment-naïve patients without cirrhosis. We aimed to evaluate the efficacy and safety of this combination in treatment-experienced patients with and without cirrhosis. METHODS We conducted a multicentre, open-label, double-arm, nonrandomized study in patients coinfected with HIV-1 and HCV genotype 1 with and without cirrhosis, who had good viral suppression on their antiretroviral regimens. All patients were pretreated with a first-generation NS3/4A protease inhibitor (PI) plus pegylated interferon/ribavirin. Patients received a fixed-dose combination of LDV/SOF for 12 weeks, or for 24 weeks if cirrhosis was present. The primary endpoint was a sustained virological response (SVR) 12 weeks after the end of therapy. Secondary endpoints included safety, pharmacokinetics and patient-reported outcomes. RESULTS Of the 68 patients enrolled, 39.7% had cirrhosis. Sixty-five patients [95.6%; 95% confidence interval (CI): 87.6-99.1%; P < 0.0001] achieved an SVR, with similar rates of SVR in those with and without cirrhosis. Tolerance was satisfactory, with mainly grade 1 or 2 adverse events. Among patient-reported outcomes, only fatigue significantly decreased at the end of treatment compared with baseline [odds ratio (OR): 0.36; 95% CI: 0.14-0.96; P = 0.04]. Mean tenofovir area under the plasma concentration-time curve (AUC) at week 4 was high, with mean ± SD AUC variation between baseline and week 4 higher in cirrhotic than in noncirrhotic patients (3261.57 ± 1920.47 ng/mL vs. 1576.15 ± 911.97 ng/mL, respectively; P = 0.03). Mild proteinuria (54.4%), hypophosphataemia (50.0%), blood bicarbonate decrease (29.4%) and hypokalaemia (13.2%) were reported. The serum creatinine level was not modified. CONCLUSIONS LDV/SOF provided a high SVR rate in PI-experienced subjects coinfected with HCV genotype 1 and HIV-1, including patients with cirrhosis.
Collapse
|
Research Support, Non-U.S. Gov't |
8 |
9 |
4
|
Amri I, Millier A, Toumi M. Minimum Clinically Important Difference in the Global Assessment Functioning in Patients with Schizophrenia. VALUE IN HEALTH : THE JOURNAL OF THE INTERNATIONAL SOCIETY FOR PHARMACOECONOMICS AND OUTCOMES RESEARCH 2014; 17:A765-A766. [PMID: 27202809 DOI: 10.1016/j.jval.2014.08.285] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
|
|
11 |
9 |
5
|
Abstract
OBJECTIVE Most of the existing studies investigating the impact of schizophrenia on utility have focused on the different stages of the disease. The objective of this study was to describe and quantify the impact of treatment-related side-effects on utility in patients with schizophrenia, using data from an observational study. METHODS This study used data from the European Schizophrenia Cohort (EuroSC), a multi-center 2-year cohort study conducted in France, England, and Germany. The EQ-5D questionnaire was completed every 6 months, as well as the Subjective Side Effect Rating Scale, assessing patient distress over extrapyramidal symptoms (EPS), weight gain, sedation, and sexual dysfunction, used to assess whether or not the patient experienced the side-effect. At first a bivariate analysis was conducted to describe utility values with and without side-effects. Then, a random effects regression analysis was performed on utility, where random effects were controlled for repeated measures on the same subjects, with potential confounding factors. Finally, findings were compared with those of previous publications. RESULTS This sample consisted of 1208 patients with schizophrenia. At the baseline visit, the most reported side-effect was EPS (almost 60% of patients), followed by sedation and weight gain (∼50% of patients for each), and sexual dysfunction (almost 30% of patients). Significant association with severity of symptoms, functioning abilities, and utility were found. Patients reporting none of the studied side-effects had an average EQ-5D index score of 0.81, found to be higher than scores of patients reporting EPS (0.70), sexual dysfunction (0.67), sedation (0.70), or weight gain (0.72). The random effects model reported a utility decrement of 0.042 for EPS, 0.022 for weight gain, 0.022 for sexual dysfunction, and 0.019 for sedation. Although the external validation was difficult due to the different methods or definitions of the side-effects, as well as the paucity of data for weight gain, sedation and sexual dysfunction, the results were generally consistent with previous studies. CONCLUSION This study aimed at quantifying the direct impact of main side-effects associated with antipsychotics on patients' utility. RESULTS suggested a significant direct impact of side-effects, with EPS being the most impactful.
Collapse
|
|
11 |
7 |
6
|
Hmaïed F, Jebri S, Saavedra MER, Yahya M, Amri I, Lucena F, Hamdi M. Comparison of Two Concentration Methods for the Molecular Detection of Enteroviruses in Raw and Treated Sewage. Curr Microbiol 2015; 72:12-8. [PMID: 26362161 DOI: 10.1007/s00284-015-0909-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2015] [Accepted: 08/03/2015] [Indexed: 02/05/2023]
Abstract
Human enteric viruses are a major causative agent of emerging waterborne diseases and constitute a serious public health concern. Environmental contamination occurs through discharge of waste materials from infected persons. Methods for viral detection should be developed to detect low infective dose of enteric viruses in environment. In this study, we aimed at comparing two concentration methods for the detection of naturally occurring enteroviruses in raw and treated sewage. In the first method, polyethylene glycol is used to concentrate viral particles from the collected samples. The second method is based on ultracentrifugation of viral particles at high speed (110,000×g). Genomes of enteroviruses were quantified by the quantitative real-time PCR method in raw and treated sewage samples. PEG-based method yielded higher genomic copies of enteric viruses (with an average of 5.9 log10 genomic copies/100 mL) when applied to raw sewage samples. While the ultracentrifugation assay in the second method decreases genomic copies number (with an average of 5.4 log10 genomic copies/100 mL). The recovery differences between the two methods were not significant when applied to clean samples (treated sewage). This could be explained by the presence of inhibitors, which interfere with qRT-PCR, in less quantity comparatively to raw sewage. PEG-based method would be more accurate for samples with high-organic matter load. This report emphasizes the importance of matrices nature on the recovery of enteroviruses from sewage samples. This should be taken into consideration for establishing standardized virological assays to ensure the virological quality control of discharged water in environment.
Collapse
|
Research Support, Non-U.S. Gov't |
10 |
7 |
7
|
Al Amri I, Ravichandran R, Sivakumar SS, Binukumar JP, Davis CA, Al Rahbi Z, Al Shukeili K, Al Kindi F. Radiotherapy pre-treatment dose validation: A second verification of monitor units (MU) with a commercial software. J Med Phys 2012; 37:235-9. [PMID: 23293456 PMCID: PMC3532753 DOI: 10.4103/0971-6203.103610] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2012] [Revised: 08/24/2012] [Accepted: 10/10/2012] [Indexed: 11/04/2022] Open
Abstract
Inversely planned intensity-modulated radiotherapy (IMRT) and stereotactic small field radiotherapy should be verified before treatment execution. A second verification is carried out for planned treatments in IMRT and 3D conformal radiotherapy (3D-CRT) using a monitor verification commercial dose calculation management software (DCMS). For the same reference point the ion-chamber measured doses are compared for IMRT plans. DCMS (Diamond) computes dose based on modified Clarkson integration, accounting for multi-leaf collimators (MLC) transmission and measured collimator scatter factors. DCMS was validated with treatment planning system (TPS) (Eclipse 6.5 Version, Varian, USA) separately. Treatment plans computed from TPS are exported to DCMS using DICOM interface. Doses are re-calculated at selected points for fields delivered to IMRT phantom (IBA Scanditronix Wellhofer) in high-energy linac (Clinac 2300 CD, Varian). Doses measured at central axis, for the same points using CC13 (0.13 cc) ion chamber with Dose 1 Electrometer (Scanditronix Wellhofer) are compared with calculated data on DCMS and TPS. The data of 53 IMRT patients with fields ranging from 5 to 9 are reported. The computed dose for selected monitor units (MU) by Diamond showed good agreement with planned doses by TPS. DCMS dose prediction matched well in 3D-CRT forward plans (0.8 ± 1.3%, n = 37) and in IMRT inverse plans (-0.1 ± 2.2%, n = 37). Ion chamber measurements agreed well with Eclipse planned doses (-2.1 ± 2.0%, n = 53) and re-calculated DCMS doses (-1.5 ± 2.6%, n = 37) in phantom. DCMS dose validation is in reasonable agreement with TPS. DCMS calculations corroborate well with ionometric measured doses in most of the treatment plans.
Collapse
|
other |
13 |
5 |
8
|
Millier A, Siegrist K, Amri I, Toumi M, Aballéa S. Social Contacts Reduce Negative Symptoms, Especially Emotional Withdrawal in Patients with Schizophrenia. VALUE IN HEALTH : THE JOURNAL OF THE INTERNATIONAL SOCIETY FOR PHARMACOECONOMICS AND OUTCOMES RESEARCH 2014; 17:A455. [PMID: 27201263 DOI: 10.1016/j.jval.2014.08.1244] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
|
|
11 |
2 |
9
|
Amri I, Millier A, Toumi M. Minimum Clinically Important Difference in the Calgary Depression Scale for Schizophrenia. VALUE IN HEALTH : THE JOURNAL OF THE INTERNATIONAL SOCIETY FOR PHARMACOECONOMICS AND OUTCOMES RESEARCH 2014; 17:A766. [PMID: 27202813 DOI: 10.1016/j.jval.2014.08.288] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
|
|
11 |
2 |
10
|
Zairi I, Mzoughi K, Mroua F, Ben Moussa F, Amri I, Kammoun S, Fennira S, Kraiem S. [Results of percutaneous mitral balloon commissurotomy in pregnant women about 12 cases]. Ann Cardiol Angeiol (Paris) 2016; 67:18-24. [PMID: 27817848 DOI: 10.1016/j.ancard.2016.10.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2015] [Accepted: 10/06/2016] [Indexed: 10/20/2022]
Abstract
INTRODUCTION Mitral stenosis (MS) is the most common valvular heart disease revealed or exacerbated by pregnancy. Percutaneous mitral balloon commissurotomy (PMC) is currently the treatment of choice when mitral valve morphology is favorable. AIM OF THE STUDY The purpose of this study is to evaluate the immediate, medium and long term results of percutaneous mitral balloon commissurotomy in pregnant women with a severe symptomatic mitral stenosis despite medical treatment. PATIENTS AND METHODS It is a retrospective study including 12 pregnant patients diagnosed with severe mitral stenosis and hospitalized in the cardiology department of Habib Thameur hospital between 1994 and 2014. A clinical and ultrasonographic monitoring was performed for over 15 years. RESULTS Mean patients age was 31.5±4.4 years. All patients were in NYHA class III or IV despite medical treatment. Mitral regurgitation was rated as moderate in four cases. Functional improvement was observed in all cases immediately after the procedure. Mitral valve area increased from 1.02±0.5cm2 averaged to 2±0.35cm2. Mitral regurgitation increased in three cases and appeared in two cases. All patients delivered at term. Newborns were all healthy. Two of them had a low birth weight. On the long term follow-up (95.58±64.1 months), five patients had mitral restenosis: two had a surgical valve replacement and three underwent a second percutaneous mitral balloon commissurotomy. CONCLUSION The effectiveness of the percutaneous mitral balloon commissurotomy is clearly documented by clinical and echocardiographic evaluation. In the case of pregnancy, the goal is not so much to obtain an optimal result but to cause hemodynamic improvement authorizing the continuation of pregnancy and childbirth.
Collapse
|
|
9 |
|
11
|
Millier A, Amri I, Toumi M. Evolution of Depressive Status in Patients with Schizophrenia: An Analysis of Patient Trajectories. VALUE IN HEALTH : THE JOURNAL OF THE INTERNATIONAL SOCIETY FOR PHARMACOECONOMICS AND OUTCOMES RESEARCH 2014; 17:A766. [PMID: 27202814 DOI: 10.1016/j.jval.2014.08.289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
|
|
11 |
|
12
|
Millier A, Amri I, Toumi M. Burden Associated with Agitation in Schizophrenia. VALUE IN HEALTH : THE JOURNAL OF THE INTERNATIONAL SOCIETY FOR PHARMACOECONOMICS AND OUTCOMES RESEARCH 2014; 17:A766. [PMID: 27202811 DOI: 10.1016/j.jval.2014.08.286] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
|
|
11 |
|
13
|
Faria S, Al Amri I, Gluszko J, Patrocinio H. 153: Do we Really Need Customized Immobilization Devices for Modern SBRT in Lung Cancer? Radiother Oncol 2016. [DOI: 10.1016/s0167-8140(16)33552-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
|
9 |
|
14
|
Ziadi S, Trimèche M, Sriha B, Denguezli M, Amri I, Mestiri S, Belajouza C, Korbi S. Granuloma multiforme: first case report in Tunisia. Pathologica 2007; 99:443-445. [PMID: 18416339] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/26/2023] Open
Abstract
Granuloma multiforme is a rare granulomatous skin disease, usually reported in sub-Saharan African countries. The exact aetiology of granuloma multiforme is still unknown. We report the case of a patient who presented clinical and histopathological features of granuloma multiforme that can be considered the first described case in Tunisia.
Collapse
|
Case Reports |
18 |
|
15
|
Al Kharusi O, Al Mamari R, Al Hosni B, Al Amri I, Al Fishawy M, Boulassel MR, Bouchareb Y. Commissioning and performance assessment of diodes and MOSFETs in in-vivo dosimetry for external beam radiation therapy. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2025; 64:275-289. [PMID: 40035814 DOI: 10.1007/s00411-025-01117-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2024] [Accepted: 02/21/2025] [Indexed: 03/06/2025]
Abstract
The precision of radiation therapy treatment depends on several calibration and quality assurance processes. In-vivo dosimetry (IVD) is used in external beam radiotherapy to evaluate the delivered versus planned dose as a patient-specific quality assurance verification procedure. This study aimed at assessing the performance of diodes (EDP-103G and EDP-203G) and metal oxide semiconductor field-effect transistors (MOSFETs) and corresponding correction factors followed by IVD evaluation in different treatment configurations. Linearity, stability, gantry angle, field size, and source-to-subject distance (SSD) were assessed across various photon energies, with correction factors determined. To minimize patient movement uncertainty, the study utilized the Alderson Rando phantom to replicate clinical setups, comparing diode and MOSFET dose readings to treatment planning system (TPS) doses. Diodes and MOSFETs were evaluated across different photon energy levels for brain, chest, and pelvis planning sites. Diodes and MOSFETs demonstrated good stability and linearity at the different utilized photon beams. Data analysis showed that MOSFETs had a slightly higher sensitivity compared to diodes in gantry angle, field size and SSD corrections. Regarding the validation process after applying the correction factors, dose variations between diode readings and TPS doses were found to be 1.89%, 1.58%, and 6.72% for brain, breast, and pelvis, respectively. In contrast, MOSFET readings were 2.40% for brain, 2.03% for chest, and 2.03% for pelvis. It is concluded that, while diode and MOSFET dosimeters both allowed for accurate patient dose measurements, for different anatomical sites, MOSFETs demonstrated better performance for the pelvis compared to diodes.
Collapse
|
|
1 |
|