1
|
Signal-correction errors in the EasyOne Pro LAB multiple-breath washout device significantly impact outcomes in children and adults. J Appl Physiol (1985) 2024; 136:460-471. [PMID: 38269412 DOI: 10.1152/japplphysiol.00096.2022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Accepted: 01/16/2024] [Indexed: 01/26/2024] Open
Abstract
Multiple-breath washout (MBW) is an established technique to assess functional residual capacity (FRC) and ventilation inhomogeneity in the lung. Indirect calculation of nitrogen concentration requires accurate measurement of gas concentrations. To investigate the accuracy of the CO2 concentration and molar mass (MM) values used for the indirect calculation of nitrogen concentration in a commercial MBW device [EasyOne Pro LAB (EOPL), ndd Medizintechnik AG, Switzerland] and its impact on outcomes. We used high-precision gas mixtures to evaluate CO2 and MM sensor output in vivo and in vitro. We developed updated algorithms to correct observed errors and assessed the impact on MBW outcomes and FRC measurement accuracy compared with body plethysmography. The respiratory exchange ratio (RER)-based adjustment of the measured CO2 signal used in the EOPL led to an overestimated CO2 signal (range -0.1% to 1.0%). In addition, an uncorrected dependence on humidity was identified. These combined effects resulted in an overestimation of expired nitrogen concentrations (range -0.7% to 2.6%), and consequently MBW outcomes. Corrected algorithms reduced the mean (SD) cumulative expired volume by 15.8% (9.7%), FRC by 6.6% (3.0%), and lung clearance index by 9.9% (7.6%). Differences in FRC between the EOPL and body plethysmography further increased. Inadequate signal correction causes RER- and humidity-dependent expired nitrogen concentration errors and overestimation of test outcomes. Updated algorithms reduce average signal error, however, RER values far from the population average still cause measurement errors. Despite improved signal accuracy, the updated algorithm increased the difference in FRC between the EOPL and body plethysmography.NEW & NOTEWORTHY We investigated the accuracy of the molar mass (MM) and CO2 sensors of a commercial multiple-breath washout device (ndd Medizintechnik AG, Switzerland). We identified humidity and respiratory exchange ratio-dependent errors that in most measurements resulted in an overestimation of expired nitrogen concentrations, and consequently, MBW results. Functional residual capacity and lung clearance index decreased by 6.6% and 9.9%, respectively. Despite improved signal accuracy, the difference in FRC between the EOPL and body plethysmography increased.
Collapse
|
2
|
Comparison of functional residual capacity between updated infant SF 6 multiple-breath washout setups. Pediatr Pulmonol 2024; 59:518-520. [PMID: 38010843 DOI: 10.1002/ppul.26770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Revised: 11/07/2023] [Accepted: 11/10/2023] [Indexed: 11/29/2023]
|
3
|
European Respiratory Society/American Thoracic Society technical statement: standardisation of the measurement of lung volumes, 2023 update. Eur Respir J 2023; 62:2201519. [PMID: 37500112 DOI: 10.1183/13993003.01519-2022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2022] [Accepted: 05/16/2023] [Indexed: 07/29/2023]
Abstract
This document updates the 2005 European Respiratory Society (ERS) and American Thoracic Society (ATS) technical standard for the measurement of lung volumes. The 2005 document integrated the recommendations of an ATS/ERS task force with those from an earlier National Heart, Lung, and Blood Institute workshop that led to the publication of background papers between 1995 and 1999 and a consensus workshop report with more in-depth descriptions and discussion. Advancements in hardware and software, new research and emerging approaches have necessitated an update to the 2005 technical standard to guide laboratory directors, physiologists, operators, pulmonologists and manufacturers. Key updates include standardisation of linked spirometry, new equipment quality control and validation recommendations, generalisation of the multiple breath washout concept beyond nitrogen, a new acceptability and grading system with addition of example tracings, and a brief review of imaging and other new techniques to measure lung volumes. Future directions and key research questions are also noted.
Collapse
|
4
|
SIMULTANEOUS MULTIPLE BREATH WASHOUT AND OXYGEN-ENHANCED MAGNETIC RESONANCE IMAGING IN HEALTHY ADULTS. Respir Med Res 2023; 83:100993. [PMID: 37058881 DOI: 10.1016/j.resmer.2023.100993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 09/23/2022] [Accepted: 12/26/2022] [Indexed: 01/11/2023]
Abstract
Lung function testing and lung imaging are commonly used techniques to monitor respiratory diseases, such as cystic fibrosis (CF). The nitrogen (N2) multiple-breath washout technique (MBW) has been shown to detect ventilation inhomogeneity in CF, but the underlying pathophysiological processes that are altered are often unclear. Dynamic oxygen-enhanced magnetic resonance imaging (OE-MRI) could potentially be performed simultaneously with MBW because both techniques require breathing of 100% oxygen (O2) and may allow for visualisation of alterations underlying impaired MBW outcomes. However, simultaneous MBW and OE-MRI has never been assessed, potentially as it requires a magnetic resonance (MR) compatible MBW equipment. In this pilot study, we assessed whether MBW and OE-MRI can be performed simultaneously using a commercial MBW device that has been modified to be MR-compatible. We performed simultaneous measurements in five healthy volunteers aged 25-35 years. We obtained O2 and N2 concentrations from both techniques, and generated O2 wash-in time constant and N2 washout maps from OE-MRI data. We obtained good quality simultaneous measurements in two healthy volunteers due to technical challenges related to the MBW equipment and poor tolerance. Oxygen and N2 concentrations from both techniques, as well as O2 wash-in time constant maps and N2 washout maps could be obtained, suggesting that simultaneous measurements may have the potential to allow for comparison and visualization of regional differences in ventilation underlying impaired MBW outcomes. Simultaneous MBW and OE-MRI measurements can be performed with a modified MBW device and may help to understand MBW outcomes, but the measurements are challenging and have poor feasibility.
Collapse
|
5
|
Variability of clinically measured lung clearance index in children with cystic fibrosis. Pediatr Pulmonol 2023; 58:197-205. [PMID: 36251441 DOI: 10.1002/ppul.26180] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Revised: 08/29/2022] [Accepted: 09/28/2022] [Indexed: 01/11/2023]
Abstract
RATIONALE The lung clearance index (LCI) is increasingly being used in the clinical surveillance of patients with cystic fibrosis (CF). However, there are limited data on long-term variability and physiologically relevant changes in LCI during routine clinical surveillance. OBJECTIVES To evaluate the long-term variability of LCI and propose a threshold for a physiologically relevant change. METHODS In children aged 4-18 years with CF, LCI was measured every 3 months as part of routine clinical surveillance during 2011-2020 in two centers. The variability of LCI during periods of clinical stability was assessed using mixed-effects models and was used to identify thresholds for physiologically relevant changes. RESULTS Repeated LCI measurements of acceptable quality (N = 858) were available in 100 patients with CF; for 74 patients, 399 visits at clinical stability were available. The variability of repeated LCI measurements over time expressed as the coefficient of variation (CV%) was 7.4%. The upper limit of normal (ULN) for relative changes in LCI between visits was 19%. CONCLUSION We report the variability of LCI in children and adolescents with CF during routine clinical surveillance. According to our data, a change in LCI beyond 19% may be considered physiologically relevant. These findings will help guide clinical decisions according to LCI changes.
Collapse
|
6
|
Breath detection algorithms affect multiple-breath washout outcomes in pre-school and school age children. PLoS One 2022; 17:e0275866. [PMID: 36240198 PMCID: PMC9565421 DOI: 10.1371/journal.pone.0275866] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Accepted: 09/23/2022] [Indexed: 11/07/2022] Open
Abstract
Background Accurate breath detection is essential for the computation of outcomes in the multiple-breath washout (MBW) technique. This is particularly important in young children, where irregular breathing is common, and the designation of inspirations and expirations can be challenging. Aim To investigate differences between a commercial and a novel breath-detection algorithm and to characterize effects on MBW outcomes in children. Methods We replicated the signal processing and algorithms used in Spiroware software (v3.3.1, Eco Medics AG). We developed a novel breath detection algorithm (custom) and compared it to Spiroware using 2,455 nitrogen (N2) and 325 sulfur hexafluoride (SF6) trials collected in infants, children, and adolescents. Results In 83% of N2 and 32% of SF6 trials, the Spiroware breath detection algorithm rejected breaths and did not use them for the calculation of MBW outcomes. Our custom breath detection algorithm determines inspirations and expirations based on flow reversal and corresponding CO2 elevations, and uses all breaths for data analysis. In trials with regular tidal breathing, there were no differences in outcomes between algorithms. However, in 10% of pre-school children tests the number of breaths detected differed by more than 10% and the commercial algorithm underestimated the lung clearance index by up to 21%. Conclusion Accurate breath detection is challenging in young children. As the MBW technique relies on the cumulative analysis of all washout breaths, the rejection of breaths should be limited. We provide an improved algorithm that accurately detects breaths based on both flow reversal and CO2 concentration.
Collapse
|
7
|
Feasibility of unsedated lung MRI in young children with cystic fibrosis. Eur Respir J 2022; 60:13993003.03112-2021. [PMID: 36137591 DOI: 10.1183/13993003.03112-2021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Accepted: 08/30/2022] [Indexed: 11/05/2022]
|
8
|
Normative multiple breath washout data in school-aged children corrected for sensor error. Eur Respir J 2022; 60:13993003.02398-2021. [PMID: 35710262 DOI: 10.1183/13993003.02398-2021] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Accepted: 06/07/2022] [Indexed: 11/05/2022]
|
9
|
Impact of Spiroware re-analysis method on multiple-breath washout outcomes in children with cystic fibrosis. J Cyst Fibros 2022; 21:e208-e209. [DOI: 10.1016/j.jcf.2022.02.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Accepted: 02/22/2022] [Indexed: 11/24/2022]
|
10
|
Monitoring disease progression in childhood bronchiectasis. Front Pediatr 2022; 10:1010016. [PMID: 36186641 PMCID: PMC9523123 DOI: 10.3389/fped.2022.1010016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Accepted: 08/29/2022] [Indexed: 11/24/2022] Open
Abstract
Bronchiectasis (not related to cystic fibrosis) is a chronic lung disease caused by a range of etiologies but characterized by abnormal airway dilatation, recurrent respiratory symptoms, impaired quality of life and reduced life expectancy. Patients typically experience episodes of chronic wet cough and recurrent pulmonary exacerbations requiring hospitalization. Early diagnosis and management of childhood bronchiectasis are essential to prevent respiratory decline, optimize quality of life, minimize pulmonary exacerbations, and potentially reverse bronchial disease. Disease monitoring potentially allows for (1) the early detection of acute exacerbations, facilitating timely intervention, (2) tracking the rate of disease progression for prognostic purposes, and (3) quantifying the response to therapies. This narrative review article will discuss methods for monitoring disease progression in children with bronchiectasis, including lung imaging, respiratory function, patient-reported outcomes, respiratory exacerbations, sputum biomarkers, and nutritional outcomes.
Collapse
|
11
|
Correction of sensor crosstalk error in Exhalyzer D multiple-breath washout device significantly impacts outcomes in children with cystic fibrosis. J Appl Physiol (1985) 2021; 131:1148-1156. [PMID: 34351818 DOI: 10.1152/japplphysiol.00338.2021] [Citation(s) in RCA: 45] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
RATIONALE Nitrogen multiple-breath washout is an established technique to assess functional residual capacity and ventilation inhomogeneity in the lung. Accurate measurement of gas concentrations is essential for the appropriate calculation of clinical outcomes. OBJECTIVES We investigated the accuracy of oxygen and carbon dioxide gas sensor measurements used for the indirect calculation of nitrogen concentration in a commercial multiple-breath washout device (Exhalyzer D, Eco Medics AG, Duernten, Switzerland) and its impact on functional residual capacity and lung clearance index. METHODS High precision calibration gas mixtures and mass spectrometry were used to evaluate sensor output. We assessed the impact of corrected signal processing on multiple-breath washout outcomes in a dataset of healthy children and children with cystic fibrosis using custom analysis software. RESULTS We found inadequate correction for the cross sensitivity of the oxygen and carbon dioxide sensors in the Exhalyzer D device. This results in an overestimation of expired nitrogen concentration, and consequently multiple-breath washout outcomes. Breath-by-breath correction of this error reduced the mean (SD) cumulative expired volume by 19.6 (5.0)%, functional residual capacity by 8.9 (2.2)%, and lung clearance index by 11.9 (4.0)%. It also substantially reduced the level of the tissue nitrogen signal at the end of measurements. CONCLUSIONS Inadequate correction for cross sensitivity in the oxygen and carbon dioxide gas sensors of the Exhalyzer D device leads to an overestimation of functional residual capacity and lung clearance index. Correction of this error is possible and could be applied by re-analyzing the measurements in an updated software version.
Collapse
|
12
|
Shedding light into the black box of infant multiple-breath washout. Pediatr Pulmonol 2021; 56:2642-2653. [PMID: 33991038 DOI: 10.1002/ppul.25464] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Revised: 04/22/2021] [Accepted: 05/08/2021] [Indexed: 11/10/2022]
Abstract
BACKGROUND Multiple-breath inert gas washout (MBW) is a sensitive technique to assess lung volumes and ventilation inhomogeneity in infancy. Poor agreement amongst commercially available setups and a lack of transparency in the underlying algorithms for the computation of infant MBW outcomes currently limit the widespread application of MBW as a surveillance tool in early lung disease. METHODS We determined all computational steps in signal processing and the calculation of MBW outcomes in the current infant WBreath/Exhalyzer D setup (Exhalyzer D device, Eco Medics AG; WBreath software version 3.28.0, ndd Medizintechnik AG; Switzerland). We developed a revised WBreath version based on current consensus guidelines and compared outcomes between the current (3.28.0) and revised (3.52.3) WBreath version. We analyzed 60 visits from 40 infants with cystic fibrosis (CF) and 20 healthy controls at 6 weeks and 1 year of age. RESULTS Investigation into the algorithms in WBreath 3.28.0 revealed discrepancies from current consensus guidelines, which resulted in a potential overestimation of functional residual capacity (FRC) and underestimation of lung clearance index (LCI). We developed a revised WBreath version (3.52.3), which overall resulted in 6.7% lower FRC (mean (SD) -1.78 (0.99) mL/kg) and 14.1% higher LCI (1.11 (0.57) TO) than WBreath version 3.28.0. CONCLUSION Comprehensive investigation into the signal processing and algorithms used for analysis of MBW measurements improves the transparency and robustness of infant MBW data. The revised software version calculates outcomes according to consensus guidelines. Future work is needed to validate and compare outcomes between infant MBW setups.
Collapse
|
13
|
Longitudinal course of clinical lung clearance index in children with cystic fibrosis. Eur Respir J 2021; 58:13993003.02686-2020. [PMID: 33361098 DOI: 10.1183/13993003.02686-2020] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Accepted: 12/07/2020] [Indexed: 01/11/2023]
Abstract
BACKGROUND Although the lung clearance index (LCI) is a sensitive marker of small airway disease in individuals with cystic fibrosis (CF), less is known about longitudinal changes in LCI during routine clinical surveillance. Here, our objectives were to describe the longitudinal course of LCI in children with CF during routine clinical surveillance and assess influencing factors. METHODS Children with CF aged 3-18 years performed LCI measurements every 3 months as part of routine clinical care between 2011 and 2018. We recorded clinical data at every visit. We used a multilevel mixed effect model to determine changes in LCI over time and identify clinical factors that influence LCI course. RESULTS We collected LCI measurements from 1204 visits (3603 trials) in 78 participants, of which 907 visits had acceptable LCI data. The average unadjusted increase in LCI for the entire population was 0.29 (95% CI 0.20-0.38) LCI units·year-1. The increase in LCI was more pronounced in adolescence (0.41 (95% CI 0.27-0.54) LCI units·year-1). Colonisation with either Pseudomonas aeruginosa or Aspergillus fumigatus, pulmonary exacerbations, CF-related diabetes and bronchopulmonary aspergillosis were associated with a higher increase in LCI over time. Adjusting for clinical risk factors reduced the increase in LCI over time to 0.24 (95% CI 0.16-0.33) LCI units·year-1. CONCLUSIONS LCI measured during routine clinical surveillance is associated with underlying disease progression in children with CF. An increased change in LCI over time should prompt further diagnostic intervention.
Collapse
|
14
|
Multiple breath washout quality control in the clinical setting. Pediatr Pulmonol 2021; 56:105-112. [PMID: 33058570 DOI: 10.1002/ppul.25119] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 10/08/2020] [Accepted: 10/10/2020] [Indexed: 01/21/2023]
Abstract
BACKGROUND Multiple breath washout (MBW) is increasingly used in the clinical assessment of patients with cystic fibrosis (CF). Guidelines for MBW quality control (QC) were developed primarily for retrospective assessment and central overreading. We assessed whether real-time QC of MBW data during the measurement improves test acceptability in the clinical setting. METHODS We implemented standardized real-time QC and reporting of MBW data at the time of the measurement in the clinical pediatric lung function laboratory in Bern, Switzerland, in children with CF aged 4-18 years. We assessed MBW test acceptability before (31 tests; 89 trials) and after (32 tests; 96 trials) implementation of real-time QC and compared agreement between reviewers. Further, we assessed the implementation of real-time QC at a secondary center in Zurich, Switzerland. RESULTS Before the implementation of real-time QC in Bern, only 58% of clinical MBW tests were deemed acceptable following retrospective QC by an experienced reviewer. After the implementation of real-time QC, MBW test acceptability improved to 75% in Bern. In Zurich, after the implementation of real-time QC, test acceptability improved from 38% to 70%. Further, the agreement between MBW operators and an experienced reviewer for test acceptability was 84% in Bern and 93% in Zurich. CONCLUSION Real-time QC of MBW data at the time of measurement is feasible in the clinical setting and results in improved test acceptability.
Collapse
|
15
|
The impact of segmentation on whole-lung functional MRI quantification: Repeatability and reproducibility from multiple human observers and an artificial neural network. Magn Reson Med 2020; 85:1079-1092. [PMID: 32892445 DOI: 10.1002/mrm.28476] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Revised: 07/16/2020] [Accepted: 07/21/2020] [Indexed: 12/11/2022]
Abstract
PURPOSE To investigate the repeatability and reproducibility of lung segmentation and their impact on the quantitative outcomes from functional pulmonary MRI. Additionally, to validate an artificial neural network (ANN) to accelerate whole-lung quantification. METHOD Ten healthy children and 25 children with cystic fibrosis underwent matrix pencil decomposition MRI (MP-MRI). Impaired relative fractional ventilation (RFV ) and relative perfusion (RQ ) from MP-MRI were compared using whole-lung segmentation performed by a physician at two time-points (At1 and At2 ), by an MRI technician (B), and by an ANN (C). Repeatability and reproducibility were assess with Dice similarity coefficient (DSC), paired t-test and Intraclass-correlation coefficient (ICC). RESULTS The repeatability within an observer (At1 vs At2 ) resulted in a DSC of 0.94 ± 0.01 (mean ± SD) and an unsystematic difference of -0.01% for RFV (P = .92) and +0.1% for RQ (P = .21). The reproducibility between human observers (At1 vs B) resulted in a DSC of 0.88 ± 0.02, and a systematic absolute difference of -0.81% (P < .001) for RFV and -0.38% (P = .037) for RQ . The reproducibility between human and the ANN (At1 vs C) resulted in a DSC of 0.89 ± 0.03 and a systematic absolute difference of -0.36% for RFV (P = .017) and -0.35% for RQ (P = .002). The ICC was >0.98 for all variables and comparisons. CONCLUSIONS Despite high overall agreement, there were systematic differences in lung segmentation between observers. This needs to be considered for longitudinal studies and could be overcome by using an ANN, which performs as good as human observers and fully automatizes MP-MRI post-processing.
Collapse
|
16
|
Airway Mucus Hyperconcentration in Non-Cystic Fibrosis Bronchiectasis. Am J Respir Crit Care Med 2020; 201:661-670. [PMID: 31765597 DOI: 10.1164/rccm.201906-1219oc] [Citation(s) in RCA: 50] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Rationale: Non-cystic fibrosis bronchiectasis is characterized by airway mucus accumulation and sputum production, but the role of mucus concentration in the pathogenesis of these abnormalities has not been characterized.Objectives: This study was designed to: 1) measure mucus concentration and biophysical properties of bronchiectasis mucus; 2) identify the secreted mucins contained in bronchiectasis mucus; 3) relate mucus properties to airway epithelial mucin RNA/protein expression; and 4) explore relationships between mucus hyperconcentration and disease severity.Methods: Sputum samples were collected from subjects with bronchiectasis, with and without chronic erythromycin administration, and healthy control subjects. Sputum percent solid concentrations, total and individual mucin concentrations, osmotic pressures, rheological properties, and inflammatory mediators were measured. Intracellular mucins were measured in endobronchial biopsies by immunohistochemistry and gene expression. MUC5B (mucin 5B) polymorphisms were identified by quantitative PCR. In a replication bronchiectasis cohort, spontaneously expectorated and hypertonic saline-induced sputa were collected, and mucus/mucin concentrations were measured.Measurements and Main Results: Bronchiectasis sputum exhibited increased percent solids, total and individual (MUC5B and MUC5AC) mucin concentrations, osmotic pressure, and elastic and viscous moduli compared with healthy sputum. Within subjects with bronchiectasis, sputum percent solids correlated inversely with FEV1 and positively with bronchiectasis extent, as measured by high-resolution computed tomography, and inflammatory mediators. No difference was detected in MUC5B rs35705950 SNP allele frequency between bronchiectasis and healthy individuals. Hypertonic saline inhalation acutely reduced non-cystic fibrosis bronchiectasis mucus concentration by 5%.Conclusions: Hyperconcentrated airway mucus is characteristic of subjects with bronchiectasis, likely contributes to disease pathophysiology, and may be a target for pharmacotherapy.
Collapse
|
17
|
Effect of breastfeeding duration on lung function, respiratory symptoms and allergic diseases in school-age children. Pediatr Pulmonol 2020; 55:1448-1455. [PMID: 32181595 DOI: 10.1002/ppul.24733] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2019] [Accepted: 03/06/2020] [Indexed: 12/25/2022]
Abstract
BACKGROUND A positive effect of breastfeeding on lung function has been demonstrated in cohorts of children with asthma or risk for asthma. We assessed the impact of breastfeeding on lung function and symptoms at the age of 6 years in an unselected, healthy birth cohort. METHODS We prospectively studied healthy term infants from the Bern-Basel Infant Lung Development (BILD) cohort from birth up to 6 years. Any breastfeeding was assessed by weekly phone calls during the first year of life. Risk factors (eg, smoking exposure, parental history of allergic conditions, and education) were obtained using standardized questionnaires. The primary outcomes were lung function parameters measured at 6 years of age by spirometry forced expiratory volume in 1 second, body plethysmography (functional residual capacity [FRCpleth ], the total lung capacity [TLCpleth ], and the effective respiratory airway resistance [Reff ]) and fractional exhaled nitric oxide (FeNO). Secondary outcomes included ever wheeze (between birth and 6 years), wheeze in the past 12 months, asthma, presence of allergic conditions, atopic dermatitis, rhinitis, and positive skin prick test at the age of 6 years. RESULTS In 377 children the mean breastfeeding duration was 36 weeks (SD 14.4). We found no association of breastfeeding duration with obstructive or restrictive lung function and FeNO. After adjustment for confounders, we found no associations of breastfeeding duration with respiratory symptoms or the presence of allergic conditions. CONCLUSION This study found no evidence of an association between breastfeeding and comprehensive lung function in unselected healthy children with long-term breastfeeding. Our findings do not support the hypothesis that the duration of breastfeeding has a direct impact on lung function in a healthy population with low asthmatic risk.
Collapse
|
18
|
Mucus accumulation in the lungs precedes structural changes and infection in children with cystic fibrosis. Sci Transl Med 2020; 11:11/486/eaav3488. [PMID: 30944166 DOI: 10.1126/scitranslmed.aav3488] [Citation(s) in RCA: 128] [Impact Index Per Article: 32.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2018] [Accepted: 03/10/2019] [Indexed: 12/12/2022]
Abstract
Although destructive airway disease is evident in young children with cystic fibrosis (CF), little is known about the nature of the early CF lung environment triggering the disease. To elucidate early CF pulmonary pathophysiology, we performed mucus, inflammation, metabolomic, and microbiome analyses on bronchoalveolar lavage fluid (BALF) from 46 preschool children with CF enrolled in the Australian Respiratory Early Surveillance Team for Cystic Fibrosis (AREST CF) program and 16 non-CF disease controls. Total airway mucins were elevated in CF compared to non-CF BALF irrespective of infection, and higher densities of mucus flakes containing mucin 5B and mucin 5AC were observed in samples from CF patients. Total mucins and mucus flakes correlated with inflammation, hypoxia, and oxidative stress. Many CF BALFs appeared sterile by culture and molecular analyses, whereas other samples exhibiting bacterial taxa associated with the oral cavity. Children without computed tomography-defined structural lung disease exhibited elevated BALF mucus flakes and neutrophils, but little/no bacterial infection. Although CF mucus flakes appeared "permanent" because they did not dissolve in dilute BALF matrix, they could be solubilized by a previously unidentified reducing agent (P2062), but not N-acetylcysteine or deoxyribonuclease. These findings indicate that early CF lung disease is characterized by an increased mucus burden and inflammatory markers without infection or structural lung disease and suggest that mucolytic and anti-inflammatory agents should be explored as preventive therapy.
Collapse
|
19
|
Normative data for multiple breath washout outcomes in school-aged Caucasian children. Eur Respir J 2019; 55:13993003.01302-2019. [DOI: 10.1183/13993003.01302-2019] [Citation(s) in RCA: 59] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2019] [Accepted: 12/10/2019] [Indexed: 12/19/2022]
Abstract
BackgroundThe multiple breath nitrogen washout (N2MBW) technique is increasingly used to assess the degree of ventilation inhomogeneity in school-aged children with lung disease. However, reference values for healthy children are currently not available. The aim of this study was to generate reference values for N2MBW outcomes in a cohort of healthy Caucasian school-aged children.MethodsN2MBW data from healthy Caucasian school-age children between 6 and 18 years old were collected from four experienced centres. Measurements were performed using an ultrasonic flowmeter (Exhalyzer D, Eco Medics AG, Duernten, Switzerland) and were analysed with commercial software (Spiroware version 3.2.1, Eco Medics AG). Normative values and upper limits of normal (ULN) were generated for lung clearance index (LCI) at 2.5% (LCI2.5%) and at 5% (LCI5%) of the initial nitrogen concentration and for moment ratios (M1/M0 and M2/M0). A prediction equation was generated for functional residual capacity (FRC).ResultsAnalysis used 485 trials from 180 healthy Caucasian children aged from 6 to 18 years old. While LCI increased with age, this increase was negligible (0.04 units·year–1 for LCI2.5%) and therefore fixed ULN were defined for this age group. These limits were 7.91 for LCI2.5%, 5.73 for LCI5%, 1.75 for M1/M0 and 6.15 for M2/M0, respectively. Height and weight were found to be independent predictors of FRC.ConclusionWe report reference values for N2MBW outcomes measured on a commercially available ultrasonic flowmeter device (Exhalyzer D, Eco Medics AG) in healthy school-aged children to allow accurate interpretation of ventilation distribution outcomes and FRC in children with lung disease.
Collapse
|
20
|
Endotracheal tube mucus as a source of airway mucus for rheological study. Am J Physiol Lung Cell Mol Physiol 2019; 317:L498-L509. [PMID: 31389736 DOI: 10.1152/ajplung.00238] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/26/2023] Open
Abstract
Muco-obstructive lung diseases (MOLDs), like cystic fibrosis and chronic obstructive pulmonary disease, affect a spectrum of subjects globally. In MOLDs, the airway mucus becomes hyperconcentrated, increasing osmotic and viscoelastic moduli and impairing mucus clearance. MOLD research requires relevant sources of healthy airway mucus for experimental manipulation and analysis. Mucus collected from endotracheal tubes (ETT) may represent such a source with benefits, e.g., in vivo production, over canonical sample types such as sputum or human bronchial epithelial (HBE) mucus. Ionic and biochemical compositions of ETT mucus from healthy human subjects were characterized and a stock of pooled ETT samples generated. Pooled ETT mucus exhibited concentration-dependent rheologic properties that agreed across spatial scales with reported individual ETT samples and HBE mucus. We suggest that the practical benefits compared with other sample types make ETT mucus potentially useful for MOLD research.
Collapse
|
21
|
Endotracheal tube mucus as a source of airway mucus for rheological study. Am J Physiol Lung Cell Mol Physiol 2019; 317:L498-L509. [PMID: 31389736 DOI: 10.1152/ajplung.00238.2019] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
Muco-obstructive lung diseases (MOLDs), like cystic fibrosis and chronic obstructive pulmonary disease, affect a spectrum of subjects globally. In MOLDs, the airway mucus becomes hyperconcentrated, increasing osmotic and viscoelastic moduli and impairing mucus clearance. MOLD research requires relevant sources of healthy airway mucus for experimental manipulation and analysis. Mucus collected from endotracheal tubes (ETT) may represent such a source with benefits, e.g., in vivo production, over canonical sample types such as sputum or human bronchial epithelial (HBE) mucus. Ionic and biochemical compositions of ETT mucus from healthy human subjects were characterized and a stock of pooled ETT samples generated. Pooled ETT mucus exhibited concentration-dependent rheologic properties that agreed across spatial scales with reported individual ETT samples and HBE mucus. We suggest that the practical benefits compared with other sample types make ETT mucus potentially useful for MOLD research.
Collapse
|
22
|
Preschool Multiple-Breath Washout Testing. An Official American Thoracic Society Technical Statement. Am J Respir Crit Care Med 2019; 197:e1-e19. [PMID: 29493315 DOI: 10.1164/rccm.201801-0074st] [Citation(s) in RCA: 73] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023] Open
Abstract
BACKGROUND Obstructive airway disease is nonuniformly distributed throughout the bronchial tree, although the extent to which this occurs can vary among conditions. The multiple-breath washout (MBW) test offers important insights into pediatric lung disease, not available through spirometry or resistance measurements. The European Respiratory Society/American Thoracic Society inert gas washout consensus statement led to the emergence of validated commercial equipment for the age group 6 years and above; specific recommendations for preschool children were beyond the scope of the document. Subsequently, the focus has shifted to MBW applications within preschool subjects (aged 2-6 yr), where a "window of opportunity" exists for early diagnosis of obstructive lung disease and intervention. METHODS This preschool-specific technical standards document was developed by an international group of experts, with expertise in both custom-built and commercial MBW equipment. A comprehensive review of published evidence was performed. RESULTS Recommendations were devised across areas that place specific age-related demands on MBW systems. Citing evidence where available in the literature, recommendations are made regarding procedures that should be used to achieve robust MBW results in the preschool age range. The present work also highlights the important unanswered questions that need to be addressed in future work. CONCLUSIONS Consensus recommendations are outlined to direct interested groups of manufacturers, researchers, and clinicians in preschool device design, test performance, and data analysis for the MBW technique.
Collapse
|
23
|
Within-breath changes in respiratory system impedance in children with cystic fibrosis. Pediatr Pulmonol 2019; 54:737-742. [PMID: 30828997 DOI: 10.1002/ppul.24281] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2018] [Accepted: 01/24/2019] [Indexed: 11/07/2022]
Abstract
BACKGROUND The aim of this study was to assess within-breath respiratory system impedance by the forced oscillation technique (FOT) in children with cystic fibrosis (CF) and relate it to the underlying lung disease. METHODS Thirty-three children with CF (median [range] age 12.0 [6-17] years) underwent FOT at 8 Hz during tidal breathing, multiple breath nitrogen washout (LCI), spirometry (FEV1), body plethysmography (RV/TLC), and magnetic resonance imaging (MRI). FOT outcomes included: mean inspiratory, expiratory, and whole breath resistance (R8INSP , R8EXP , R8TOT ) and reactance (X8INSP , X8EXP , X8TOT ), and the differences between X8INSP and X8EXP (ΔX8). Morphological changes were evaluated by MRI using CF-specific morphological scores. Spearman correlation was performed to examine the correlation between FOT indices and other parameters. RESULTS FEV1 was negatively correlated with R8EXP (r = -0.52, P = 0.002) and ΔX8 (r = -0.55, P = 0.001), and positively correlated with and X8EXP (r = 0.56, P < 0.001). RV/TLC was positively correlated with R8EXP (r = 0.43, P = 0.013), and ΔX8 (r = 0.54, P = 0.001) and negatively correlated with X8EXP (r = -0.54, P = 0.001). We found poor correlation between FOT parameters and LCI and no correlation between FOT parameters and MRI scores. CONCLUSION In children with CF, changes in within-breath FOT parameters are consistent with peripheral obstruction and dynamic airway compression, while they are not associated with ventilation heterogeneities and morphological alterations.
Collapse
|
24
|
Single-breath washout and association with structural lung disease in children with cystic fibrosis. Pediatr Pulmonol 2019; 54:587-594. [PMID: 30758143 DOI: 10.1002/ppul.24271] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Accepted: 01/16/2019] [Indexed: 11/09/2022]
Abstract
BACKGROUND In children with cystic fibrosis (CF) lung clearance index (LCI) from multiple-breath washout (MBW) correlates with structural lung disease. As a shorter test, single-breath washout (SBW) represents an attractive alternative to assess the ventilation distribution, however, data for the correlation with lung imaging are lacking. METHODS We assessed correlations between phase III slope (SIII) of double-tracer gas SBW, nitrogen MBW indices (LCI and moment ratios for overall ventilation distribution, Scond, and Sacin for conductive and mainly acinar ventilation, respectively) and structural lung disease assessed by chest computed tomography (CT) in children with CF. RESULTS In a prospective cross-sectional study data from MBW, SBW, and chest CT were obtained in 32 children with CF with a median (range) age of 8.2 (5.2-16.3) years. Bronchiectasis was present in 24 (75%) children and air trapping was present in 29 (91%). Median (IQR) SIII of SBW was -138.4 (150.6) mg/mol. We found no association between SIII with either the MBW outcomes or CT scores (n = 23, association with bronchiectasis extent r = 0.10, P = 0.64). LCI and Scond were associated with bronchiectasis extent (n = 23, r = 0.57, P = 0.004; r = 0.60, P = 0.003, respectively). CONCLUSIONS Acinar ventilation inhomogeneity measured by SBW was not associated with structural lung disease on CT. Double-tracer SBW added no benefit to indices measured by MBW.
Collapse
|
25
|
Leaks during multiple-breath washout: characterisation and influence on outcomes. ERJ Open Res 2018; 4:00012-2017. [PMID: 29497618 PMCID: PMC5827412 DOI: 10.1183/23120541.00012-2017] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2017] [Accepted: 12/13/2017] [Indexed: 11/19/2022] Open
Abstract
Nitrogen multiple-breath washout (N2MBW) is increasingly used in patients with cystic fibrosis. The current European Respiratory Society/American Thoracic Society consensus statement for MBW recommends the rejection of measurements with leaks. However, it is unclear whether this is necessary for all types of leaks. Here, our aim was to 1) model and 2) apply air leaks, and 3) to assess their influence on the primary MBW outcomes of lung clearance index and functional residual capacity. We investigated the influence of air leaks at various locations (pre-, intra- and post-capillary), sizes, durations and stages of the washout. Modelled leaks were applied to existing N2MBW data from 10 children by modifying breath tables. In addition, leaks were applied to the equipment during N2MBW measurements performed by one healthy adolescent. All modelled and applied leaks resulted in statistically significant but heterogeneous effects on lung clearance index and functional residual capacity. In all types of continuous inspiratory leaks exceeding a certain size, the end of the washout was not reached. For practical application, we illustrated six different “red flags”, i.e. signs that enable easy identification of leaks during measurements. Air leaks during measurement significantly influence N2MBW outcomes. The influence of leaks on MBW outcomes is dependent on the location, relation to breath cycle, duration, stage of washout and size of the leak. We identified a range of signs to help distinguish leaks from physiological noise. The influence of leaks on nitrogen MBW outcomes is complex, dynamic and dependent on the size, duration, location and position of leaks during the washout and breathing cyclehttp://ow.ly/PbHV30hB91H
Collapse
|
26
|
The clinical utility of lung clearance index in early cystic fibrosis lung disease is not impacted by the number of multiple-breath washout trials. ERJ Open Res 2018; 4:00094-2017. [PMID: 29707562 PMCID: PMC5912932 DOI: 10.1183/23120541.00094-2017] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2017] [Accepted: 11/24/2017] [Indexed: 11/05/2022] Open
Abstract
The lung clearance index (LCI) from the multiple-breath washout (MBW) test is a promising surveillance tool for pre-school children with cystic fibrosis (CF). Current guidelines for MBW testing recommend that three acceptable trials are required. However, success rates to achieve these criteria are low in children aged <7 years and feasibility may improve with modified pre-school criteria that accepts tests with two acceptable trials. This study aimed to determine if relationships between LCI and clinical outcomes of CF lung disease differ when only two acceptable MBW trials are assessed. Healthy children and children with CF aged 3-6 years were recruited for MBW testing. Children with CF also underwent bronchoalveolar lavage fluid collection and a chest computed tomography scan. MBW feasibility increased from 46% to 75% when tests with two trials were deemed acceptable compared with tests where three acceptable trials were required. Relationships between MBW outcomes and markers of pulmonary inflammation, infection and structural lung disease were not different between tests with three acceptable trials compared with tests with two acceptable trials. This study indicates that pre-school MBW data from two acceptable trials may provide sufficient information on ventilation distribution if three acceptable trials are not possible.
Collapse
|
27
|
The effect of 100% oxygen on tidal breathing parameters in preschool children. Eur Respir J 2017; 49:49/6/1601959. [DOI: 10.1183/13993003.01959-2016] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2016] [Accepted: 03/05/2017] [Indexed: 11/05/2022]
|
28
|
Effect of posture on lung ventilation distribution and associations with structure in children with cystic fibrosis. J Cyst Fibros 2017; 16:713-718. [PMID: 28188011 DOI: 10.1016/j.jcf.2017.01.013] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2016] [Revised: 01/23/2017] [Accepted: 01/24/2017] [Indexed: 11/30/2022]
Abstract
BACKGROUND We assessed the effect of posture on ventilation distribution and the impact on associations with structural lung disease. METHODS Multiple breath washout (MBW) was performed in seated and supine postures in 25 healthy children and 21 children with CF. Children with CF also underwent a chest CT scan. Functional residual capacity (FRC), lung clearance index (LCI) and moment ratios were calculated from the MBW test. CT scans were evaluated for CF-related structural lung disease. RESULTS FRC was lower in the supine than in the seated posture, whereas LCI was higher in the supine than in the seated posture. In children with CF, associations between LCI and the extent of structural lung disease were stronger when performed in the supine posture. CONCLUSIONS Body posture influences lung volumes and ventilation distribution in both healthy children and children with CF. MBW testing in the supine posture strengthened associations with structural lung damage.
Collapse
|
29
|
End-inspiratory molar mass step correction for analysis of infant multiple breath washout tests. Pediatr Pulmonol 2017; 52:10-13. [PMID: 27273874 DOI: 10.1002/ppul.23499] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2016] [Accepted: 05/26/2016] [Indexed: 11/11/2022]
Abstract
A refined software algorithm was recently proposed for the analysis of infant multiple breath washout (MBW) measurements. The proposed algorithm uses the change in end-inspiratory molar mass between the wash-in and wash-out curves (EIMM-step) to define the required step response correction of the MM signal and is assumed to provide an accurate evaluation of complete washout of the tracer gas, in comparison to the current software algorithm which applies the change in end-expiratory molar mass (EEMM)-step. We aimed to evaluate the use of the EIMM-step method in a broad range of infants. We performed retrospective analyses comparing the EIMM- and EEMM-step change methods in MBW data collected from infants with cystic fibrosis (CF), infants born preterm, and healthy infants using an ultrasonic flowmeter. We found that the EIMM-step correction significantly increased LCI and functional residual capacity (FRC) in infants with CF, preterm infants, and healthy infants compared with the EEMM-step method. In addition, more than half the measurements that were technically acceptable and repeatable using the EEMM-step correction in healthy infants were excluded after using the EIMM-step correction. We found a large difference between the EIMM- and EEMM-steps in healthy infants indicating incomplete washout, suggesting the need for a longer washout time with using the EIMM-step analysis method. The data indicates that the EIMM-step analysis method may have the potential to generate false abnormal LCI values in individuals without lung disease. Revised normative data may be required if this method is universally adopted. Pediatr Pulmonol. 2017;52:10-13. © 2016 Wiley Periodicals, Inc.
Collapse
|
30
|
Respiratory infection rates differ between geographically distant paediatric cystic fibrosis cohorts. ERJ Open Res 2016; 2:00014-2016. [PMID: 27957481 PMCID: PMC5140014 DOI: 10.1183/23120541.00014-2016] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2016] [Accepted: 07/26/2016] [Indexed: 11/10/2022] Open
Abstract
Respiratory infections are a major cause of pulmonary decline in children with cystic fibrosis (CF). We compared the prevalence of infection in early life at geographically distant CF treatment centres participating in the same surveillance programme in Australia. Lower airway microbiology, inflammation and structural lung disease at annual review were evaluated for 260 children 0–8 years old with CF at 1032 visits to CF treatment centres in Melbourne or Perth. Melbourne patients were more likely to be culture-positive for common respiratory pathogens at all age groups (odds ratio (OR) 1.85, 95% CI 1.33–2.58). Subjects <2 years old in Melbourne were also more likely to have neutrophil elastase present (OR 3.11, 95% CI 1.62–5.95). Bronchiectasis (OR 2.02, 95% CI 1.21–3.38) and air trapping (OR 2.53, 95% CI 1.42–4.51) in subjects 2–5 years old was more common in Melbourne subjects. The severity of structural lung disease was also worse in Melbourne patients >5 years old. Patients at both centres had a similar rate of hospitalisations and prescribed antibiotics. No procedural differences were identified that could explain the disparity between pathogen prevalence. Geographical differences in early acquisition of infection may contribute to variability in outcomes between CF centres. Infection rates different between two Australian paediatric cystic fibrosis patient cohortshttp://ow.ly/PAmG302IYL4
Collapse
|
31
|
Mucin Agarose Gel Electrophoresis: Western Blotting for High-molecular-weight Glycoproteins. J Vis Exp 2016. [PMID: 27341489 DOI: 10.3791/54153] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
Abstract
Mucins, the heavily-glycosylated proteins lining mucosal surfaces, have evolved as a key component of innate defense by protecting the epithelium against invading pathogens. The main role of these macromolecules is to facilitate particle trapping and clearance while promoting lubrication of the mucosa. During protein synthesis, mucins undergo intense O-glycosylation and multimerization, which dramatically increase the mass and size of these molecules. These post-translational modifications are critical for the viscoelastic properties of mucus. As a result of the complex biochemical and biophysical nature of these molecules, working with mucins provides many challenges that cannot be overcome by conventional protein analysis methods. For instance, their high-molecular-weight prevents electrophoretic migration via regular polyacrylamide gels and their sticky nature causes adhesion to experimental tubing. However, investigating the role of mucins in health (e.g., maintaining mucosal integrity) and disease (e.g., hyperconcentration, mucostasis, cancer) has recently gained interest and mucins are being investigated as a therapeutic target. A better understanding of the production and function of mucin macromolecules may lead to novel pharmaceutical approaches, e.g., inhibitors of mucin granule exocytosis and/or mucolytic agents. Therefore, consistent and reliable protocols to investigate mucin biology are critical for scientific advancement. Here, we describe conventional methods to separate mucin macromolecules by electrophoresis using an agarose gel, transfer protein into nitrocellulose membrane, and detect signal with mucin-specific antibodies as well as infrared fluorescent gel reader. These techniques are widely applicable to determine mucin quantitation, multimerization and to test the effects of pharmacological compounds on mucins.
Collapse
|
32
|
Lung Clearance Index and Structural Lung Disease on Computed Tomography in Early Cystic Fibrosis. Am J Respir Crit Care Med 2016; 193:60-7. [PMID: 26359952 DOI: 10.1164/rccm.201507-1409oc] [Citation(s) in RCA: 132] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
RATIONALE The lung clearance index is a measure of ventilation distribution derived from the multiple-breath washout technique. It has been suggested as a surrogate for chest computed tomography to detect structural lung abnormalities in individuals with cystic fibrosis (CF); however, the associations between lung clearance index and early structural lung disease are unclear. OBJECTIVES We assessed the ability of the lung clearance index to reflect structural lung disease on the basis of chest computed tomography across the entire pediatric age range. METHODS Lung clearance index was assessed in 42 infants (ages 0-2 yr), 39 preschool children (ages 3-6 yr), and 38 school-age children (7-16 yr) with CF before chest computed tomography and in 72 healthy control subjects. Scans were evaluated for CF-related structural lung disease using the Perth-Rotterdam Annotated Grid Morphometric Analysis for Cystic Fibrosis quantitative outcome measure. MEASUREMENTS AND MAIN RESULTS In infants with CF, lung clearance index is insensitive to structural disease (κ = -0.03 [95% confidence interval, -0.05 to 0.16]). In preschool children with CF, lung clearance index correlates with total disease extent. In school-age children, lung clearance index correlates with extent of total disease, bronchiectasis, and air trapping. In preschool and school-age children, lung clearance index has a good positive predictive value (83-86%) but a poor negative predictive value (50-55%) to detect the presence of bronchiectasis. CONCLUSIONS These data suggest that lung clearance index may be a useful surveillance tool to monitor structural lung disease in preschool and school-age children with CF. However, lung clearance index cannot replace chest computed tomography to screen for bronchiectasis in this population.
Collapse
|
33
|
Impact of lung disease on respiratory impedance in young children with cystic fibrosis. Eur Respir J 2015; 46:1672-9. [PMID: 26405283 DOI: 10.1183/13993003.00156-2015] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2015] [Accepted: 07/14/2015] [Indexed: 11/05/2022]
Abstract
This study aimed to evaluate the ability of the forced oscillation technique (FOT) to detect underlying lung disease in preschool children with cystic fibrosis (CF) diagnosed following newborn screening.184 children (aged 3-6 years) with CF underwent lung function testing on 422 occasions using the FOT to assess respiratory resistance and reactance at the time of their annual bronchoalveolar lavage collection and chest computed tomography scan. We examined associations between FOT outcomes and the presence and progression of respiratory inflammation, infection and structural lung disease.Children with CF who had pronounced respiratory disease, including free neutrophil elastase activity, infection with pro-inflammatory pathogens and structural lung abnormalities had similar FOT outcomes to those children without detectable lung disease. In addition, the progression of lung disease over 1 year was not associated with worsening FOT outcomes.We conclude that the forced oscillation technique is relatively insensitive to detect underlying lung disease in preschool children with CF. However, FOT may still be of value in improving our understanding of the physiological changes associated with early CF lung disease.
Collapse
|
34
|
Progressive ventilation inhomogeneity in infants with cystic fibrosis after pulmonary infection. Eur Respir J 2015; 46:1680-90. [PMID: 26381521 DOI: 10.1183/13993003.00622-2015] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2014] [Accepted: 06/28/2015] [Indexed: 12/28/2022]
Abstract
Measures of ventilation distribution are promising for monitoring early lung disease in cystic fibrosis (CF). This study describes the cross-sectional and longitudinal impacts of pulmonary inflammation and infection on ventilation homogeneity in infants with CF.Infants diagnosed with CF underwent multiple breath washout (MBW) testing and bronchoalveolar lavage at three time points during the first 2 years of life.Measures were obtained for 108 infants on 156 occasions. Infants with a significant pulmonary infection at the time of MBW showed increases in lung clearance index (LCI) of 0.400 units (95% CI 0.150-0.648; p=0.002). The impact was long lasting, with previous pulmonary infection leading to increased ventilation inhomogeneity over time compared to those who remained free of infection (p<0.05). Infection with Haemophilus influenzae was particularly detrimental to the longitudinal lung function in young children with CF where LCI was increased by 1.069 units for each year of life (95% CI 0.484-1.612; p<0.001).Pulmonary infection during the first year of life is detrimental to later lung function. Therefore, strategies aimed at prevention, surveillance and eradication of pulmonary pathogens are paramount to preserve lung function in infants with CF.
Collapse
|
35
|
Abstract
Biomarkers in cystic fibrosis are used i. for the measurement of cystic fibrosis transmembrane regulator function in order to diagnose cystic fibrosis, and ii. to assess aspects of lung disease severity (e.g. inflammation, infection). Effective biomarkers can aid disease monitoring and contribute to the development of new therapies. The tests of cystic fibrosis transmembrane regulator function each have unique strengths and weaknesses, and biomarkers of inflammation, infection and tissue destruction have the potential to enhance the management of cystic fibrosis through the early detection of disease processes. The development of biomarkers of cystic fibrosis lung disease, in particular airway inflammation and infection, is influenced by the challenges of obtaining relevant samples from infants and children for whom early detection and treatment of disease might have the greatest long term benefits.
Collapse
|
36
|
Early Respiratory Infection Is Associated with Reduced Spirometry in Children with Cystic Fibrosis. Am J Respir Crit Care Med 2014; 190:1111-6. [DOI: 10.1164/rccm.201407-1277oc] [Citation(s) in RCA: 121] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
37
|
Interpretation of lung function in infants and young children with cystic fibrosis. Respirology 2014; 19:792-9. [PMID: 24948040 DOI: 10.1111/resp.12329] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2014] [Revised: 04/09/2014] [Accepted: 04/15/2014] [Indexed: 11/29/2022]
Abstract
The last decade has seen a significant advance in understanding about early lung disease in cystic fibrosis (CF). As studies that have measured lung function in preschool years are conducted in association with surveillance of infection, inflammation and early structural changes, and emerging longitudinal data become available, a better insight into the very early onset and nature of such lung disease is emerging. Interventions during the preschool years are increasingly viewed as being crucial to delaying and minimizing disease progression as this is the most important period of postnatal life in terms of lung development and airway remodelling. Lung function measurement in CF is potentially an important assessment tool and is used in routine clinical practice in several centres already. Results of studies from lung function tests that, on the basis of their underpinning physiology, are viewed as being best suited currently for the early detection of lung disease in CF are reviewed.
Collapse
|
38
|
Early life arsenic exposure and acute and long-term responses to influenza A infection in mice. ENVIRONMENTAL HEALTH PERSPECTIVES 2013; 121:1187-93. [PMID: 23968752 PMCID: PMC3801203 DOI: 10.1289/ehp.1306748] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2013] [Accepted: 07/23/2013] [Indexed: 05/04/2023]
Abstract
BACKGROUND Arsenic is a significant global environmental health problem. Exposure to arsenic in early life has been shown to increase the rate of respiratory infections during infancy, reduce childhood lung function, and increase the rates of bronchiectasis in early adulthood. OBJECTIVE We aimed to determine if early life exposure to arsenic exacerbates the response to early life influenza infection in mice. METHODS C57BL/6 mice were exposed to arsenic in utero and throughout postnatal life. At 1 week of age, a subgroup of mice were infected with influenza A. We then assessed the acute and long-term effects of arsenic exposure on viral clearance, inflammation, lung structure, and lung function. RESULTS Early life arsenic exposure reduced the clearance of and exacerbated the inflammatory response to influenza A, and resulted in acute and long-term changes in lung mechanics and airway structure. CONCLUSIONS Increased susceptibility to respiratory infections combined with exaggerated inflammatory responses throughout early life may contribute to the development of bronchiectasis in arsenic-exposed populations.
Collapse
|
39
|
In utero exposure to low dose arsenic via drinking water impairs early life lung mechanics in mice. BMC Pharmacol Toxicol 2013; 14:13. [PMID: 23419080 PMCID: PMC3584853 DOI: 10.1186/2050-6511-14-13] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2012] [Accepted: 01/31/2013] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Exposure to arsenic via drinking water is a significant environmental issue affecting millions of people around the world. Exposure to arsenic during foetal development has been shown to impair somatic growth and increase the risk of developing chronic respiratory diseases. The aim of this study was to determine if in utero exposure to low dose arsenic via drinking water is capable of altering lung growth and postnatal lung mechanics. METHODS Pregnant C57BL/6 mice were given drinking water containing 0, 10 (current World Health Organisation (WHO) maximum contaminant level) or 100 μg/L arsenic from gestational day 8 to birth. Birth outcomes and somatic growth were monitored. Plethysmography and the forced oscillation technique were used to collect measurements of lung volume, lung mechanics, pressure-volume curves and the volume dependence of lung mechanics in male and female offspring at two, four, six and eight weeks of age. RESULTS In utero exposure to low dose arsenic via drinking water resulted in low birth weight and impaired parenchymal lung mechanics during infancy. Male offspring were more susceptible to the effects of arsenic on growth and lung mechanics than females. All alterations to lung mechanics following in utero arsenic exposure were recovered by adulthood. CONCLUSIONS Exposure to arsenic at the current WHO maximum contaminant level in utero impaired somatic growth and the development of the lungs resulting in alterations to lung mechanics during infancy. Deficits in growth and lung development in early life may contribute to the increased susceptibility of developing chronic respiratory disease in arsenic exposed human populations.
Collapse
|
40
|
In utero exposure to arsenic alters lung development and genes related to immune and mucociliary function in mice. ENVIRONMENTAL HEALTH PERSPECTIVES 2013; 121:244-50. [PMID: 23221970 PMCID: PMC3569690 DOI: 10.1289/ehp.1205590] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/07/2012] [Accepted: 11/29/2012] [Indexed: 05/03/2023]
Abstract
BACKGROUND Exposure to arsenic via drinking water is a global environmental health problem. In utero exposure to arsenic via drinking water increases the risk of lower respiratory tract infections during infancy and mortality from bronchiectasis in early adulthood. OBJECTIVES We aimed to investigate how arsenic exposure in early life alters lung development and pathways involved in innate immunity. METHODS Pregnant BALB/c, C57BL/6, and C3H/HeARC mice were exposed to 0 (control) or 100 μg/L arsenic via drinking water from gestation day 8 until the birth of their offspring. We measured somatic growth, lung volume, and lung mechanics of mice at 2 weeks of age. We used fixed lungs for structural analysis and collected lung tissue for gene expression analysis by microarray. RESULTS The response to arsenic was genetically determined, and C57BL/6 mice were the most susceptible. Arsenic-exposed C57BL/6 mice were smaller in size, had smaller lungs, and had impaired lung mechanics compared with controls. Exposure to arsenic in utero up-regulated the expression of genes in the lung involved in mucus production (Clca3, Muc5b, Scgb3a1), innate immunity (Reg3γ, Tff2, Dynlrb2, Lplunc1), and lung morphogenesis (Sox2). Arsenic exposure also induced mucous cell metaplasia and increased expression of CLCA3 protein in the large airways. CONCLUSIONS Alterations in somatic growth, lung development, and the expression of genes involved in mucociliary clearance and innate immunity in the lung are potential mechanisms through which early life arsenic exposure impacts respiratory health.
Collapse
|
41
|
Fiber-type dependence of stretch-induced force enhancement in rat skeletal muscle. Muscle Nerve 2010; 42:769-77. [PMID: 20976780 DOI: 10.1002/mus.21744] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
When an active muscle is stretched, the force increases due to strain of contractile and noncontractile proteins. We examined this force enhancement in rat extensor digitorum longus (EDL) and soleus muscles, which differ in their composition of these proteins, and their susceptibility to damage. Small stretches were applied at different velocities during isometric contractions from which we quantified the velocity-dependent contractile and velocity-independent noncontractile contributions to force enhancement. Whereas the contractile contribution was significantly greater in soleus than EDL, the noncontractile force enhancement was significantly greater in EDL than soleus, and increased ≈6-fold after damaging eccentric contractions. The increased contractile stiffness may be functionally beneficial in slow muscle, as resistance to lengthening is fundamental to maintaining posture. Following stretch-induced muscle damage this capacity is compromised, leading to increased strain of noncontractile proteins that may facilitate the activation of signaling pathways involved in muscle adaptation to injury.
Collapse
|
42
|
Left ventricular mass and systolic function in human immunodeficiency virus-infected patients after weight loss. Am J Cardiol 2000; 86:1040-3, A11. [PMID: 11053726 DOI: 10.1016/s0002-9149(00)01148-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
Transthoracic echocardiography was performed on 27 patients with human immunodificiency virus after weight loss and in 20 lean controls. Left ventricular mass index was significantly higher and left ventricular fractional shortening was significantly lower in patients with human immunodificiency virus after weight loss than in lean, normal controls.
Collapse
|