1
|
Linking connectivity of deep brain stimulation of nucleus accumbens area with clinical depression improvements: a retrospective longitudinal case series. Eur Arch Psychiatry Clin Neurosci 2024; 274:685-696. [PMID: 37668723 PMCID: PMC10994999 DOI: 10.1007/s00406-023-01683-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Accepted: 08/14/2023] [Indexed: 09/06/2023]
Abstract
Treatment-resistant depression is a severe form of major depressive disorder and deep brain stimulation is currently an investigational treatment. The stimulation's therapeutic effect may be explained through the functional and structural connectivities between the stimulated area and other brain regions, or to depression-associated networks. In this longitudinal, retrospective study, four female patients with treatment-resistant depression were implanted for stimulation in the nucleus accumbens area at our center. We analyzed the structural and functional connectivity of the stimulation area: the structural connectivity was investigated with probabilistic tractography; the functional connectivity was estimated by combining patient-specific stimulation volumes and a normative functional connectome. These structural and functional connectivity profiles were then related to four clinical outcome scores. At 1-year follow-up, the remission rate was 66%. We observed a consistent structural connectivity to Brodmann area 25 in the patient with the longest remission phase. The functional connectivity analysis resulted in patient-specific R-maps describing brain areas significantly correlated with symptom improvement in this patient, notably the prefrontal cortex. But the connectivity analysis was mixed across patients, calling for confirmation in a larger cohort and over longer time periods.
Collapse
|
2
|
Subthalamic stimulation has acute psychotropic effects and improves neuropsychiatric fluctuations in Parkinson's disease. BMJ Neurol Open 2024; 6:e000524. [PMID: 38196982 PMCID: PMC10773312 DOI: 10.1136/bmjno-2023-000524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/24/2023] [Indexed: 01/11/2024] Open
Abstract
Background Subthalamic nucleus deep brain stimulation (STN-DBS) is a well-established treatment for motor complications in Parkinson's disease (PD). However, its effects on neuropsychiatric symptoms remain disputed. The aim of this study was to evaluate the effects of STN-DBS on neuropsychiatric symptoms in PD. Methods We retrospectively assessed 26 patients with PD who underwent a preoperative levodopa challenge and postoperative levodopa and stimulation challenges 1 year after STN-DBS. Based on the Neuropsychiatric Fluctuations Scale, Neuropsychiatric State Scores and Neuropsychiatric Fluctuation Indices (NFIs) were calculated. Mixed-effects models with random effects for intercept were used to examine the association of Neuropsychiatric State Score and NFI with the different assessment conditions. Results In acute challenge conditions, there was an estimated increase of 15.9 points in the Neuropsychiatric State Score in stimulation ON conditions (95% CI 11.4 to 20.6, p<0.001) and 7.6 points in medication ON conditions (95% CI 3.3 to 11.9, p<0.001). Neuropsychiatric fluctuations induced by levodopa, quantified with NFI, decreased by 35.54% (95% CI 49.3 to 21.8, p<0.001) 1 year after STN-DBS. Conclusions Bilateral STN-DBS at therapeutic parameters has acute psychotropic effects similar to levodopa and can modulate and decrease levodopa-induced neuropsychiatric fluctuations.
Collapse
|
3
|
Programming of subthalamic nucleus deep brain stimulation with hyperdirect pathway and corticospinal tract-guided parameter suggestions. Hum Brain Mapp 2023. [PMID: 37318767 PMCID: PMC10365233 DOI: 10.1002/hbm.26390] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 05/22/2023] [Accepted: 05/24/2023] [Indexed: 06/16/2023] Open
Abstract
Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is an effective treatment for advanced Parkinson's disease. Stimulation of the hyperdirect pathway (HDP) may mediate the beneficial effects, whereas stimulation of the corticospinal tract (CST) mediates capsular side effects. The study's objective was to suggest stimulation parameters based on the activation of the HDP and CST. This retrospective study included 20 Parkinson's disease patients with bilateral STN DBS. Patient-specific whole-brain probabilistic tractography was performed to extract the HDP and CST. Stimulation parameters from monopolar reviews were used to estimate volumes of tissue activated and to determine the streamlines of the pathways inside these volumes. The activated streamlines were related to the clinical observations. Two models were computed, one for the HDP to estimate effect thresholds and one for the CST to estimate capsular side effect thresholds. In a leave-one-subject-out cross-validation, the models were used to suggest stimulation parameters. The models indicated an activation of 50% of the HDP at effect threshold, and 4% of the CST at capsular side effect threshold. The suggestions for best and worst levels were significantly better than random suggestions. Finally, we compared the suggested stimulation thresholds with those from the monopolar reviews. The median suggestion errors for the effect threshold and side effect threshold were 1 and 1.5 mA, respectively. Our stimulation models of the HDP and CST suggested STN DBS settings. Prospective clinical studies are warranted to optimize tract-guided DBS programming. Together with other modalities, these may allow for assisted STN DBS programming.
Collapse
|
4
|
Deep Brain Stimulation: When to Test Directional? Mov Disord Clin Pract 2023; 10:434-439. [PMID: 36949800 PMCID: PMC10026308 DOI: 10.1002/mdc3.13667] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Revised: 12/09/2022] [Accepted: 01/08/2023] [Indexed: 01/26/2023] Open
Abstract
Background Directional deep brain stimulation (DBS) allows for steering of the stimulation field, but extensive and time-consuming testing of all segmented contacts is necessary to identify the possible benefit of steering. It is therefore important to determine under which circumstances directional current steering is advantageous. Methods Fifty two Parkinson's disease patients implanted in the STN with a directional DBS system underwent a standardized monopolar programming session 5 to 9 months after implantation. Individual contacts were tested for a potential advantage of directional stimulation. Results were used to build a prediction model for the selection of ring levels that would benefit from directional stimulation. Results On average, there was no significant difference in therapeutic window between ring-level contact and best directional contact. However, according to our standardized protocol, 35% of the contacts and 66% of patients had a larger therapeutic window under directional stimulation compared to ring-mode. The segmented contacts warranting directional current steering could be predicted with a sensitivity of 79% and a specificity of 57%. Conclusion To reduce time required for DBS programming, we recommend additional directional contact testing initially only on ring-level contacts with a therapeutic window of less than 2.0 mA.
Collapse
|
5
|
Deep transformation models for functional outcome prediction after acute ischemic stroke. Biom J 2022. [PMID: 36494091 DOI: 10.1002/bimj.202100379] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 09/13/2022] [Accepted: 10/20/2022] [Indexed: 12/14/2022]
Abstract
In many medical applications, interpretable models with high prediction performance are sought. Often, those models are required to handle semistructured data like tabular and image data. We show how to apply deep transformation models (DTMs) for distributional regression that fulfill these requirements. DTMs allow the data analyst to specify (deep) neural networks for different input modalities making them applicable to various research questions. Like statistical models, DTMs can provide interpretable effect estimates while achieving the state-of-the-art prediction performance of deep neural networks. In addition, the construction of ensembles of DTMs that retain model structure and interpretability allows quantifying epistemic and aleatoric uncertainty. In this study, we compare several DTMs, including baseline-adjusted models, trained on a semistructured data set of 407 stroke patients with the aim to predict ordinal functional outcome three months after stroke. We follow statistical principles of model-building to achieve an adequate trade-off between interpretability and flexibility while assessing the relative importance of the involved data modalities. We evaluate the models for an ordinal and dichotomized version of the outcome as used in clinical practice. We show that both tabular clinical and brain imaging data are useful for functional outcome prediction, whereas models based on tabular data only outperform those based on imaging data only. There is no substantial evidence for improved prediction when combining both data modalities. Overall, we highlight that DTMs provide a powerful, interpretable approach to analyzing semistructured data and that they have the potential to support clinical decision-making.
Collapse
|
6
|
Programming of subthalamic nucleus deep brain stimulation for Parkinson's disease with sweet spot-guided parameter suggestions. Front Hum Neurosci 2022; 16:925283. [PMID: 36393984 PMCID: PMC9663652 DOI: 10.3389/fnhum.2022.925283] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Accepted: 09/30/2022] [Indexed: 10/24/2023] Open
Abstract
Deep Brain Stimulation (DBS) is an effective treatment for advanced Parkinson's disease. However, identifying stimulation parameters, such as contact and current amplitudes, is time-consuming based on trial and error. Directional leads add more stimulation options and render this process more challenging with a higher workload for neurologists and more discomfort for patients. In this study, a sweet spot-guided algorithm was developed that automatically suggested stimulation parameters. These suggestions were retrospectively compared to clinical monopolar reviews. A cohort of 24 Parkinson's disease patients underwent bilateral DBS implantation in the subthalamic nucleus at our center. First, the DBS' leads were reconstructed with the open-source toolbox Lead-DBS. Second, a sweet spot for rigidity reduction was set as the desired stimulation target for programming. This sweet spot and estimations of the volume of tissue activated were used to suggest (i) the best lead level, (ii) the best contact, and (iii) the effect thresholds for full therapeutic effect for each contact. To assess these sweet spot-guided suggestions, the clinical monopolar reviews were considered as ground truth. In addition, the sweet spot-guided suggestions for best lead level and best contact were compared against reconstruction-guided suggestions, which considered the lead location with respect to the subthalamic nucleus. Finally, a graphical user interface was developed as an add-on to Lead-DBS and is publicly available. With the interface, suggestions for all contacts of a lead can be generated in a few seconds. The accuracy for suggesting the best out of four lead levels was 56%. These sweet spot-guided suggestions were not significantly better than reconstruction-guided suggestions (p = 0.3). The accuracy for suggesting the best out of eight contacts was 41%. These sweet spot-guided suggestions were significantly better than reconstruction-guided suggestions (p < 0.001). The sweet spot-guided suggestions of each contact's effect threshold had a mean error of 1.2 mA. On an individual lead level, the suggestions can vary more with mean errors ranging from 0.3 to 4.8 mA. Further analysis is warranted to improve the sweet spot-guided suggestions and to account for more symptoms and stimulation-induced side effects.
Collapse
|
7
|
Dynamics of recent thymic emigrants in pediatric recipients of allogeneic hematopoetic stem cell transplantation. Bone Marrow Transplant 2022; 57:620-626. [PMID: 35140350 DOI: 10.1038/s41409-022-01594-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 01/11/2022] [Accepted: 01/19/2022] [Indexed: 11/09/2022]
Abstract
After allogeneic hematopoietic stem cell transplantation (allo-HSCT), the recurrence of recent thymic emigrants (RTE) and self-tolerant T cells indicate normalized thymic function. From 2008 to 2019, we retrospectively analyzed the RTE-reconstitution rate and the minimal time to reach normal age-specific first percentiles for CD31+CD45RA+CD4+T cells in 199 pediatric patients after allo-HSCT for various malignant and non-malignant diseases. The impact of clinically significant graft-versus-host disease (GvHD), age at transplantation, underlying disease and cumulative area under the curve of busulfan on RTE-reemergence was assessed in multivariable longitudinal analysis. RTE-reconstitution (coefficient -0.24, 95% CI -0.33 to -0.14, p < 0.001) was slowed down by GvHD and the time to reach P1 was significantly longer (Event Time Ratio 1.49, 95% CI 1.25 to 1.78, p < 0.001). Older age at transplantation was also associated with a slower RTE-reconstitution (coefficient -0.028, 95% CI -0.04 to -0.02, p < 0.001) and time to reach P1 was significantly longer (Event Time Ratio 1.03, 95% CI 1.02 to 1.05, p < 0.001). RTE-reconstitution velocity was not influenced by underlying disease or cumulative busulfan exposure. In summary, duration until thymic reactivation was independent of both conditioning intensity and underlying disease and was negatively influenced by older age and GvHD.
Collapse
|
8
|
Targeting the posterior subthalamic area for essential tremor: proposal for MRI-based anatomical landmarks. J Neurosurg 2019; 131:820-827. [PMID: 30497206 DOI: 10.3171/2018.4.jns18373] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Accepted: 04/12/2018] [Indexed: 12/12/2022]
Abstract
OBJECTIVE Deep brain stimulation (DBS) of the posterior subthalamic area (PSA) is an alternative to thalamic DBS for the treatment of essential tremor (ET). The dentato-rubro-thalamic tract (DRTT) has recently been proposed as the anatomical substrate underlying effective stimulation. For clinical purposes, depiction of the DRTT mainly depends on diffusion tensor imaging (DTI)-based tractography, which has some drawbacks. The objective of this study was to present an accurate targeting strategy for DBS of the PSA based on anatomical landmarks visible on MRI and to evaluate clinical effectiveness. METHODS The authors performed a retrospective cohort study of a prospective series of 11 ET patients undergoing bilateral DBS of the PSA. The subthalamic nucleus and red nucleus served as anatomical landmarks to define the target point within the adjacent PSA on 3-T T2-weighted MRI. Stimulating contact (SC) positions with reference to the midcommissural point were analyzed and projected onto the stereotactic atlas of Morel. Postoperative outcome assessment after 6 and 12 months was based on change in Tremor Rating Scale (TRS) scores. RESULTS Actual target position corresponded to the intended target based on anatomical landmarks depicted on MRI. The total TRS score was reduced (improved) from 47.2 ± 15.7 to 21.3 ± 10.7 (p < 0.001). No severe complication occurred. The mean SC position projected onto the PSA at the margin of the cerebellothalamic fascicle and the zona incerta. CONCLUSIONS Targeting of the PSA based on anatomical landmarks representable on MRI is reliable and leads to accurate lead placement as well as good long-term clinical outcome.
Collapse
|
9
|
Stimulation of the globus pallidus internus in the treatment of Parkinson's disease: Long-term results of a monocentric cohort. Parkinsonism Relat Disord 2019; 64:118-123. [DOI: 10.1016/j.parkreldis.2019.03.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2018] [Revised: 03/06/2019] [Accepted: 03/14/2019] [Indexed: 10/27/2022]
|
10
|
Directional stimulation of subthalamic nucleus sweet spot predicts clinical efficacy: Proof of concept. Brain Stimul 2019; 12:1127-1134. [PMID: 31130498 DOI: 10.1016/j.brs.2019.05.001] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2018] [Revised: 03/30/2019] [Accepted: 05/02/2019] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND Directional deep brain stimulation (dDBS) of the subthalamic nucleus for Parkinson's disease (PD) increases the therapeutic window. However, empirical programming of the neurostimulator becomes more complex given the increasing number of stimulation parameters. A better understanding of dDBS is needed to improve therapy and help guide postoperative programming. OBJECTIVE To determine whether clinical effects of dDBS can be predicted in individual patients based on lead location and volume of tissue activated (VTA) modelling. METHODS We analysed a prospective series of 28 PD patients. Imaging analysis and systematic clinical testing performed 4-6 months postoperatively yielded location, clinical efficacy and corresponding therapeutic windows for 272 directional contacts. We calculated the corresponding VTAs to build a probabilistic stimulation map using voxel-wise statistical analysis. RESULTS We found a positive and statistically significant correlation between the overlap ratio of a patient's individual stimulation volume and the probabilistic map's sweet spot -defined as the 10% voxels with the highest clinical efficacy values (average Spearman's rho = 0.43, average p ≤ 0.036). Patients who had a larger therapeutic window with directional compared to omnidirectional stimulation had a larger distance between the electrode and the sweet spot centroid (average distances 2.3 vs. 1.5 mm, p = 0.0019). CONCLUSION Our analysis provides new insights into how the definition of a probabilistic sweet spot based on directional stimulation data and individual VTA modelling can be applied to predict clinically effective directional stimulation and help guide clinicians with the intricate postoperative DBS programming.
Collapse
|
11
|
Accuracy of different three-dimensional subcortical human brain atlases for DBS -lead localisation. Neuroimage Clin 2018; 20:868-874. [PMID: 30282063 PMCID: PMC6169097 DOI: 10.1016/j.nicl.2018.09.030] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2018] [Revised: 08/17/2018] [Accepted: 09/25/2018] [Indexed: 11/05/2022]
Abstract
BACKGROUND Accurate interindividual comparability of deep brain stimulation (DBS) lead locations in relation to the surrounding anatomical structures is of eminent importance to define and understand effective stimulation areas. The objective of the current work is to compare the accuracy of the DBS lead localisation relative to the STN in native space with four recently developed three-dimensional subcortical brain atlases in the MNI template space. Accuracy is reviewed by anatomical and volumetric analysis as well as intraoperative electrophysiological data. METHODS Postoperative lead localisations of 10 patients (19 hemispheres) were analysed in each individual patient based on Brainlab software (native space) and after normalization into the MNI space and application of 4 different human brain atlases using Lead-DBS toolbox within Matlab (template space). Each patient's STN was manually segmented and the relation between the reconstructed lead and the STN was compared to the 4 atlas-based STN models by applying the Dice coefficient. The length of intraoperative electrophysiological STN activity along different microelectrode recording tracks was measured and compared to reconstructions in native and template space. Descriptive non-parametric statistical tests were used to calculate differences between the 4 different atlases. RESULTS The mean STN volume of the study cohort was 153.3 ± 40.3 mm3 (n = 19). This is similar to the STN volume of the DISTAL atlas (166 mm3; p = .22), but significantly larger compared to the other atlases tested in this study. The anatomical overlap of the lead-STN-reconstruction was highest for the DISTAL atlas (0.56 ± 0.18) and lowest for the PD25 atlas (0.34 ± 0.17). A total number of 47 MER trajectories through the STN were analysed. There was a statistically significant discrepancy of the electrophysiogical STN activity compared to the reconstructed STN of all four atlases (p < .0001). CONCLUSION Lead reconstruction after normalization into the MNI template space and application of four different atlases led to different results in terms of the DBS lead position relative to the STN. Based on electrophysiological and imaging data, the DISTAL atlas led to the most accurate display of the reconstructed DBS lead relative to the DISTAL-based STN.
Collapse
|
12
|
TDM-controlled ring resonator arrays for fast, fixed-wavelength optical biosensing. OPTICS EXPRESS 2018; 26:22356-22365. [PMID: 30130930 DOI: 10.1364/oe.26.022356] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Accepted: 07/19/2018] [Indexed: 06/08/2023]
Abstract
A novel control concept for serial ring resonator arrays based on a time-division multiplex (TDM) approach is presented. It allows fast sampling rates in terms of biological kinetics. The novelty consists of using both thermal tuning of the effective refractive index and thermo-optical multiplexing for the silicon-on-insulator (SOI) ring resonator arrays, without the need for a tunable laser source. Using a fixed wavelength, fast read-out rates of 100 Hz are demonstrated for each ring.
Collapse
|
13
|
Directional local field potentials: A tool to optimize deep brain stimulation. Mov Disord 2018; 33:159-164. [PMID: 29150884 PMCID: PMC5768242 DOI: 10.1002/mds.27215] [Citation(s) in RCA: 103] [Impact Index Per Article: 17.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2017] [Revised: 08/21/2017] [Accepted: 10/03/2017] [Indexed: 12/01/2022] Open
Abstract
BACKGROUND Although recently introduced directional DBS leads provide control of the stimulation field, programing is time-consuming. OBJECTIVES Here, we validate local field potentials recorded from directional contacts as a predictor of the most efficient contacts for stimulation in patients with PD. METHODS Intraoperative local field potentials were recorded from directional contacts in the STN of 12 patients and beta activity compared with the results of the clinical contact review performed after 4 to 7 months. RESULTS Normalized beta activity was positively correlated with the contact's clinical efficacy. The two contacts with the highest beta activity included the most efficient stimulation contact in up to 92% and that with the widest therapeutic window in 74% of cases. CONCLUSION Local field potentials predict the most efficient stimulation contacts and may provide a useful tool to expedite the selection of the optimal contact for directional DBS. © 2017 The Authors. Movement Disorders published by Wiley Periodicals, Inc. on behalf of International Parkinson and Movement Disorder Society.
Collapse
|
14
|
|
15
|
Photoluminescence of (YGd)2O3:Eu phosphors produced by nanoparticle-seeded flame-assisted spray pyrolysis. ACTA ACUST UNITED AC 2011. [DOI: 10.1088/1757-899x/18/10/102018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
16
|
Design rules for p-i-n diode carriers sweeping in nano-rib waveguides on SOI. OPTICS EXPRESS 2011; 19:9915-9922. [PMID: 21643248 DOI: 10.1364/oe.19.009915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
In this paper we present a detailed analysis of the carrier lifetime for a p-i-n junction on silicon nano-rib waveguides. Several factors determining efficiency of carriers removal from the waveguiding region will be discussed. We compare different structure geometries and spacings between p and n doped regions to show the way to optimize electrons and holes sweeping for CW nonlinear optical devices.
Collapse
|
17
|
Ultrashort pulse generation from diode pumped mode-locked Yb3+:sesquioxide single crystal lasers. OPTICS EXPRESS 2011; 19:2904-2909. [PMID: 21369112 DOI: 10.1364/oe.19.002904] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
We present diode pumped SESAM supported Kerr-lens mode locked laser operation based on Yb3+:Sc2O3 and Yb3+:Lu2O3 single crystals. Pulses as short as 71 fs with an average power of 1.09 W were obtained from an Yb3+:Lu2O3 single crystal. Yb3+:Sc2O3 delivered pulses as short as 81 fs with an average power of 840 mW. The mode locked laser operation was stable for longer than 2 hours.
Collapse
|
18
|
Continuous-wave and modelocked Yb:YCOB thin disk laser: first demonstration and future prospects. OPTICS EXPRESS 2010; 18:19201-19208. [PMID: 20940816 DOI: 10.1364/oe.18.019201] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Yb:YCOB is a very attractive material for femtosecond pulse generation given its broad emission bandwidth. We demonstrate continuous-wave power scaling in the thin disk geometry to the 100-W level with a 40% optical-to-optical efficiency in multi-mode operation. Furthermore, we present initial modelocking results in the thin disk geometry, achieving pulse durations as short as 270 fs. The modelocked average power is, however, limited to less than 5 W because of transverse mode degradation. This is caused by anisotropic thermal aberrations in the 15% Yb-doped thin disks which were 300 to 400 µm thick. This result confirms the potential of Yb:YCOB to generate short femtosecond pulses in the thin disk geometry but also makes clear that significantly thinner disks are required to overcome the thermal limitations for high power operation.
Collapse
|
19
|
Nonlinear spectroscopic properties of Yb3+-doped sesquioxides Lu2O3 and Sc2O3. OPTICS EXPRESS 2010; 18:11173-11180. [PMID: 20588976 DOI: 10.1364/oe.18.011173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
We report on the measurements of near-UV excited-state absorption (ESA) spectra and refractive index changes (RICs) in the two ytterbium doped laser crystals Yb:Lu2O3 and Yb:Sc2O3. ESA is assigned to ligand-to-metal charge transfer (LMCT) absorption transitions and RICs to the polarizability changes experienced by the Yb3+ ions due to these strong electric-dipole allowed absorption bands.
Collapse
|
20
|
Femtosecond Yb:Lu(2)O(3) thin disk laser with 63 W of average power. OPTICS LETTERS 2009; 34:2823-2825. [PMID: 19756117 DOI: 10.1364/ol.34.002823] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
We present successful power-scaling of an Yb:Lu(2)O(3) thin disk laser to record high-power levels both in cw and mode-locked operation. In a simple multimode resonator we achieved 149 W of output power in cw operation with 73% optical-to-optical efficiency (eta(opt)). Building an 81 MHz fundamental transverse mode resonator with dispersion compensation and a semiconductor saturable absorber mirror (SESAM) for passive mode locking we achieved 63 W of average power in 535 fs pulses (eta(opt)=35%). The output beam is nearly diffraction limited (M(2)<1.2). The 0.78 microJ pulses with a peak power of 1.28 MW had a central wavelength of 1034 nm and were close to the Fourier transform limit. With an SESAM with a larger modulation depth we obtained pulses as short as 329 fs at 40 W average power corresponding to a pulse energy of 0.49 microJ and a peak power of 1.32 MW.
Collapse
|
21
|
Efficient femtosecond high power Yb:Lu(2)O(3) thin disk laser. OPTICS EXPRESS 2007; 15:16966-16971. [PMID: 19550987 DOI: 10.1364/oe.15.016966] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
We demonstrate the first passively mode-locked thin disk laser based on Yb:Lu(2)O(3). The laser generates 370-fs pulses with 20.5 W of average power in a diffraction-limited beam (M(2) < 1.1). The nearly transform-limited pulses have a spectral bandwidth of 3.4 nm centered near 1034 nm. With slightly longer pulses (523 fs) we obtained 24 W of average power at a pump power of 56 W, resulting in an optical-to-optical efficiency of 43%, which is higher than for any previously mode-locked thin disk laser.
Collapse
|
22
|
Abstract
Given its specific thermal characteristics, the sesquioxide crystal Lu(2)O(3) is a particularly promising laser host material. We demonstrate mode locking of a Yb:Lu(2)O(3) laser by use of a semiconductor saturable-absorber mirror. The laser emits up to 470 mW in the picosecond regime, corresponding to a pump efficiency as high as 32%. With dispersion compensation, pulses as short as 220 fs at an average power of 266 mW are obtained at 1033.5 nm. To our knowledge, this is the first demonstration of a femtosecond oscillator based on Yb:Lu(2)O(3).
Collapse
|
23
|
Abstract
E-field measurements are an important task for the investigation of newly developed hyperthermia applicators as well as for online control of hyperthermia treatments. Compact and non-perturbing integrated optical E-field sensors based on LiNbO3 as well as optical E-field sensors based on infrared emitting diodes and light bulbs are suitable for nearfield measurements of hyperthermia antennas. In order to investigate their properties a calibration cell with transverse electromagnetic (TEM) waves has been constructed. By using this cell, calibration curves and directional patterns for all sensors have been measured. Due to the threshold behaviour of the IRED and light bulb sensor, only the LiNbO3 sensor is capable of measuring weak fields inside an applicator or a homogeneous phantom.
Collapse
|
24
|
|
25
|
Scanning E-field sensor device for online measurements in annular phased-array systems. Int J Radiat Oncol Biol Phys 1999; 43:927-37. [PMID: 10098449 DOI: 10.1016/s0360-3016(98)00490-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
PURPOSE A measurement device for noninvasive and simultaneous control of antennas during regional radiofrequency (rf) hyperthermia and, subsequently, the estimation of the power distribution in the interior of patients are essential preconditions for further technological progress. Aiming at this, the feasibility of an electro-optical electric field sensor was investigated during clinical rf hyperthermia. MATERIAL AND METHODS The electro-optical electric field (E-field) sensor is based on lithiumniobate crystals and the Mach-Zehnder interferometer structure, and was tested in an earlier phantom study. For this study, a mechanical scanning device was developed allowing the registration of the E-field during clinical application. Data were recorded along a curve in the water bolus of the SIGMA 60 applicator of the annular phased-array system BSD-2000 (BSD Medical Corp., Salt Lake City, UT) close to the base points of the flat biconical dipole antennas. The results were compared with modeling calculations using the finite-difference time-domain (FDTD) method. For the latter, different antenna models were assumed. For systematic registration of the E-field curves in amplitude and phase, we employed an elliptical lamp phantom with fat-equivalent ring (filled with saline solution) and an elliptical polyacrylamide phantom with acrylic glass wall. Further measurements were carried out during the treatment of 5 patients with 20 hyperthermia treatments. RESULTS Data of both phantom and patient measurements can be satisfactorily described by the FDTD method, if the antenna model is refined by taking into account the conical form of the dipoles and the special dielectric environment of the feeding point. Phase deviations can be entered ex posteriori for correction in the calculation algorithm. A comparison of amplifier power measurement (forward and backward power) and bolus E-field scans near the antenna base points demonstrates that E-field measurements between antennas and patient are a necessity for the appropriate characterization of antenna radiation properties. These measurements are sensitive to variations of the lossy medium in position and shape, and can be correctly predicted with current models. However, the differences between different patients are moderate and unspecific in both calculations and measurements, with fluctuations at maximum of 30 degrees in phases and 40% in amplitudes. CONCLUSIONS The measurement method presented here turned out to be a practical tool for online registration of E-fields in phases and amplitudes along arbitrary curves in a water bolus or phantom. It can be utilized to evaluate antenna design and modeling calculations and leads, thus, to a better understanding of complicated multiantenna systems. In clinical routine, it can be employed as input for patient-specific hyperthermia planning and, finally, for the realization of online control with subsequent optimization of the power distribution in the patient.
Collapse
|
26
|
|
27
|
Optical and photoelectrical studies of charge-transfer processes in YAlO3:Ti crystals. PHYSICAL REVIEW. B, CONDENSED MATTER 1996; 54:6141-6149. [PMID: 9986628 DOI: 10.1103/physrevb.54.6141] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/12/2023]
|
28
|
Multicenter German reference data base for peripheral quantitative computer tomography. Technol Health Care 1995; 3:69-73. [PMID: 8574764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
The wide spread use of bone densitometers in Germany and other European countries has required the establishment of a validated reference population data base. A semianthropomorphic forearm cross-calibration phantom (EFP), developed during a concerted research action of the European Union's programme in Biomedical Engineering (COMAC-BME), was used to cross-calibrate the peripheral quantitative computer tomography (pQCT) devices at four German centers participating in the multicenter study. In total, 723 women and 208 men were included in the normal data base. No significant regional differences were found between the data of the different centers. In addition to the manufacturers calibration standard, proper calibration of the pQCT devices could be monitored during collection of the normal female and male data base. As a merit of the COMAC-BME study the measurements obtained with all pQCT devices thus ensured an uniform reference data base for distal radius measurements in Germany.
Collapse
|
29
|
Near-infrared emission of Cr4+-doped garnets: Lifetimes, quantum efficiencies, and emission cross sections. PHYSICAL REVIEW. B, CONDENSED MATTER 1995; 51:17323-17331. [PMID: 9978759 DOI: 10.1103/physrevb.51.17323] [Citation(s) in RCA: 48] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/12/2023]
|
30
|
Multicenter German reference data base for peripheral quantitative computer tomography. Technol Health Care 1995. [DOI: 10.3233/thc-1995-3201] [Citation(s) in RCA: 25] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
31
|
Abstract
An integrated electro-optical (eo) E field sensor is developed on the basis of a Ti:LiNbO3 Mach-Zehnder interferometer. A measuring device based on the lock-in principle is introduced to register the E field in phase and amplitude using this E field probe. Segmented electrodes are used to minimize influences from the dielectric surroundings on the base point capacitance of the receiving dipole. The operating point is stabilized against drift phenomena resulting from optical damage and pyroelectric effect. Sensitivity, dynamic range, harmonic distortions and mechanical properties of a prototype of this electro-optical E field sensor are evaluated. A phantom setup in the SIGMA-60 applicator was developed to test this electro-optical sensor for hyperthermia applications. Power deposition patterns of various standard adjustments of the SIGMA ring are visualized in an elliptical lamp phantom. Simultaneously, E field in phase and amplitude is determined on a closed curve in 10 degrees steps around the phantom in a substitute bolus. The numbers are stored and utilized as boundary conditions in a two-dimensional finite elements code which calculates the SAR distribution on an appropriate triangular grid inside the closed curve. An excellent qualitative agreement is obtained between visualized and calculated SAR patterns. This novel measurement method is therefore suitable for noninvasive monitoring of SAR patterns during clinical application of regional radiofrequency hyperthermia.
Collapse
|
32
|
|
33
|
The influence of site symmetry on the spectroscopic properties of laser ions. Acta Crystallogr A 1984. [DOI: 10.1107/s0108767384095416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
34
|
Intensity-dependent nonreciprocal phase shift in fiber-optic gyroscopes for light sources with low coherence. OPTICS LETTERS 1982; 7:623-625. [PMID: 19714112 DOI: 10.1364/ol.7.000623] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
It is shown that light sources of low coherence will exhibit intensity fluctuations similar to those of thermal light, at least after traveling through a fiber with material dispersion. These fluctuation yield a vanishing intensity-dependent nonreciprocal phase shift for fiber gyroscopes.
Collapse
|
35
|
Sensitivity of a fiber-optic gyroscope to environmental magnetic fields. OPTICS LETTERS 1982; 7:180-182. [PMID: 19710864 DOI: 10.1364/ol.7.000180] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
It is shown that environmental magnetic fields may cause a considerable error for the detected rotation rate even though the line integral of the magnetic field along the fiber vanishes. Experimentally, it has been shown that the earth's magnetic field yields a bias uncertainty of about 10 degrees /h, which can be reduced by at least 1 order of magnitude if the fiber coil is protected against environmental magnetic fields.
Collapse
|
36
|
|