1
|
Knight BP, Goyal R, Pelosi F, Flemming M, Horwood L, Morady F, Strickberger SA. Outcome of patients with nonischemic dilated cardiomyopathy and unexplained syncope treated with an implantable defibrillator. J Am Coll Cardiol 1999; 33:1964-70. [PMID: 10362200 DOI: 10.1016/s0735-1097(99)00148-5] [Citation(s) in RCA: 136] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
OBJECTIVES The purpose of this study was to determine the outcome of patients with nonischemic dilated cardiomyopathy, unexplained syncope and a negative electrophysiology test who are treated with an implantable defibrillator. BACKGROUND Patients with nonischemic cardiomyopathy and unexplained syncope may be at high risk for sudden cardiac death, and they are sometimes treated with an implantable defibrillator. METHODS This study prospectively determined the outcome of 14 consecutive patients who had a nonischemic cardiomyopathy, unexplained syncope and a negative electrophysiology test and who underwent defibrillator implantation (Syncope Group). Nineteen consecutive patients with a nonischemic cardiomyopathy and a cardiac arrest who were treated with a defibrillator (Arrest Group) served as a control group. RESULTS Seven of 14 patients (50%) in the Syncope Group received appropriate shocks for ventricular arrhythmias during a mean follow-up of 24+/-13 months, compared with 8 of 19 patients (42%) in the Arrest Group during a mean follow-up of 45+/-40 months (p = 0.1). The mean duration from device implantation until the first appropriate shock was 32+/-7 months (95% confidence interval [CI], 18 to 45 months) in the Syncope Group compared to 72+/-12 months (95% CI, 48 to 96 months) in the Arrest Group (p = 0.1). Among patients who received appropriate shocks, the mean time from defibrillator implantation to the first appropriate shock was 10+/-14 months in the Syncope Group, compared with 48+/-47 months in the Arrest Group (p = 0.06). Recurrent syncope was always associated with ventricular tachyarrhythmias. CONCLUSIONS The high incidence of appropriate defibrillator shocks and the association of recurrent syncope with ventricular arrhythmias support the treatment of patients with nonischemic cardiomyopathy, unexplained syncope and a negative electrophysiology test with an implantable defibrillator.
Collapse
|
Comparative Study |
26 |
136 |
2
|
Sticherling C, Chough SP, Baker RL, Wasmer K, Oral H, Tada H, Horwood L, Kim MH, Pelosi F, Michaud GF, Strickberger SA, Morady F, Knight BP. Prevalence of central venous occlusion in patients with chronic defibrillator leads. Am Heart J 2001; 141:813-6. [PMID: 11320371 DOI: 10.1067/mhj.2001.114195] [Citation(s) in RCA: 79] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
BACKGROUND Many patients with previously implanted ventricular defibrillators are candidates for an upgrade to a device capable of atrial-ventricular sequential or multisite pacing. The prevalence of venous occlusion after placement of transvenous defibrillator leads is unknown. The purpose of this study was to determine the prevalence of central venous occlusion in asymptomatic patients with chronic transvenous defibrillator leads. METHODS Thirty consecutive patients with a transvenous defibrillator lead underwent bilateral contrast venography of the cephalic, axillary, subclavian, and brachiocephalic veins as well as the superior vena cava before an elective defibrillator battery replacement. The mean time between transvenous defibrillator lead implantation and venography was 45 +/- 21 months. Sixteen patients had more than 1 lead in the same subclavian vein. No patient had clinical signs of venous occlusion. RESULTS One (3%) patient had a complete occlusion of the subclavian vein, 1 (3%) patient had a 90% subclavian vein stenosis, 2 (7%) patients had a 75% to 89% subclavian stenosis, 11 (37%) patients had a 50% to 74% subclavian stenosis, and 15 (50%) patients had no subclavian stenosis. CONCLUSIONS The low prevalence of subclavian vein occlusion or severe stenosis among defibrillator recipients found in this study suggests that the placement of additional transvenous leads in a patient who already has a ventricular defibrillator is feasible in a high percentage of patients (93%).
Collapse
|
Comparative Study |
24 |
79 |
3
|
Strickberger SA, Hummel JD, Daoud E, Niebauer M, Williamson BD, Man KC, Horwood L, Schmittou A, Kalbfleisch SJ, Langberg JJ. Implantation by electrophysiologists of 100 consecutive cardioverter defibrillators with nonthoracotomy lead systems. Circulation 1994; 90:868-72. [PMID: 8044958 DOI: 10.1161/01.cir.90.2.868] [Citation(s) in RCA: 56] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
BACKGROUND Traditional lead systems for implantable cardioverter defibrillators (ICDs) require a thoracotomy for placement. Nonthoracotomy lead systems are available and are usually implanted by an electrophysiologist and a surgeon. The purpose of this study was to prospectively evaluate the safety and efficacy of ICD implantation with a nonthoracotomy lead system by electrophysiologists. METHODS AND RESULTS A consecutive series of 100 patients (mean age, 61 +/- 13 years, +/- SD) underwent ICD implantation with a nonthoracotomy lead system while intubated and under general anesthesia. Seventy-seven patients had coronary artery disease, 15 had idiopathic cardiomyopathy, 6 had miscellaneous heart disease, and 2 had structurally normal hearts. The mean ejection fraction was 0.29 +/- 0.13. Sixty-eight patients had suffered a cardiac arrest, and 32 had had ventricular tachycardia or syncope. All patients except 9 underwent electrophysiological testing and had failed 1 +/- 1 drug trials before ICD implantation. Three types of nonthoracotomy lead systems were used. The nonthoracotomy lead with an ICD was successfully implanted in 96 patients (96%). Of the unsuccessful implants, 1 patient did not have venous access, the passive fixation lead in 1 would not remain lodged, 1 had elevated defibrillation thresholds, and 1 developed a hemopneumothorax while venous access was being obtained. The mean defibrillation threshold was 17 +/- 6 J. The mean procedure duration was 161 +/- 57 minutes. When a subcutaneous patch was used (n = 58), the procedure duration was 189 +/- 5 minutes, and when a subcutaneous patch was not required (n = 40), the procedure lasted 123 +/- 37 minutes (P < .0001). Patients remained in the hospital 4.5 +/- 4.1 days after implantation, with no procedure-related deaths. Acute complications occurred in 10 patients; 2 had lead dislodgments, 1 with previous abdominal surgery had his abdominal cavity entered (without other complications) while the ICD pocket was being made, 1 had postoperative heart failure, 1 developed a large hematoma when anticoagulation therapy was initiated, 3 required reintubation because of excessive anesthesia, 1 developed superficial cellulitis, and 1 developed a hemopneumothorax secondary to a lacerated subclavian vein. During 6 +/- 3 months of follow-up, 2 patients developed lead fractures. CONCLUSIONS (1) Electrophysiologists can implant an ICD with a nonthoracotomy lead system safely and with a high success rate; (2) use of a subcutaneous patch correlates with longer procedure durations; and (3) special precautions should be taken in patients with previous abdominal surgery.
Collapse
|
|
31 |
56 |
4
|
Horwood L, Brouillette RT, McGregor CD, Manoukian JJ, Constantin E. Testing for Pediatric Obstructive Sleep Apnea When Health Care Resources Are Rationed. JAMA Otolaryngol Head Neck Surg 2014; 140:616-23. [DOI: 10.1001/jamaoto.2014.778] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
|
|
11 |
39 |
5
|
Pelosi F, Oral H, Kim MH, Sticherling C, Horwood L, Knight BP, Michaud GF, Morady F, Strickberger SA. Effect of chronic amiodarone therapy on defibrillation energy requirements in humans. J Cardiovasc Electrophysiol 2000; 11:736-40. [PMID: 10921789 DOI: 10.1111/j.1540-8167.2000.tb00043.x] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
INTRODUCTION The effect of oral amiodarone therapy on defibrillation energy requirements in patients with an implantable defibrillator has not been established. METHODS AND RESULTS Twenty-one consecutive patients with implantable biphasic waveform defibrillators underwent a step-down determination of the defibrillation energy requirement 211 +/- 12 days before and 73 +/- 22 days after initiation of amiodarone therapy (mean total dose 26.7 +/- 11.1 g). Serum amiodarone and desethylamiodarone concentrations were measured at the time of defibrillation energy requirement determination. The mean defibrillation energy requirement before amiodarone therapy was 9.9 +/- 4.6 J. After initiation of amiodarone therapy, the mean defibrillation energy requirement increased to 13.7 +/- 5.6 J (P = 0.004). A linear relationship between the amiodarone (P = 0.02, r = 0.6), desethylamiodarone (P = 0.02, r = 0.6), and combined amiodarone-desethylamiodarone concentrations (P = 0.01, r = 0.6) and the defibrillation energy requirement was noted. Stepwise regression analysis demonstrated that the combined amiodarone-desethylamiodarone concentration was the only independent predictor of increase in the defibrillation energy requirement. CONCLUSION Chronic oral amiodarone therapy increases the defibrillation energy requirement by approximately 62% in patients with an implantable defibrillator. The combined amiodarone-desethylamiodarone concentration is directly related to the increase in the defibrillation energy requirement.
Collapse
|
|
25 |
38 |
6
|
Tokano T, Pelosi F, Flemming M, Horwood L, Souza JJ, Zivin A, Knight BP, Goyal R, Man KC, Morady F, Strickberger SA. Long-term evaluation of the ventricular defibrillation energy requirement. J Cardiovasc Electrophysiol 1998; 9:916-20. [PMID: 9786072 DOI: 10.1111/j.1540-8167.1998.tb00132.x] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
INTRODUCTION Defibrillation energy requirements in patients with nonthoracotomy defibrillators may increase within several months after implantation. However, the stability of the defibrillation energy requirement beyond 1 year has not been reported. The purpose of this study was to characterize the defibrillation energy requirement during 2 years of clinical follow-up. METHODS AND RESULTS Thirty-one consecutive patients with a biphasic nonthoracotomy defibrillation system underwent defibrillation energy requirement testing using a step-down technique (20, 15, 12, 10, 8, 6, 5, 4, 3, 2, and 1 J) during defibrillator implantation, and then 24 hours, 2 months, 1 year, and 2 years after implantation. The mean defibrillation energy requirement during these evaluations was 10.9+/-5.5 J, 12.3+/-7.3 J, 11.7+/-5.6 J, 10.2+/-4.0 J, and 11.7+/-7.4 J, respectively (P = 0.4). The defibrillation energy requirement was noted to have increased by 10 J or more after 2 years of follow-up in five patients. In one of these patients, the defibrillation energy requirement was no longer associated with an adequate safety margin, necessitating revision of the defibrillation system. There were no identifiable clinical characteristics that distinguished patients who did and did not develop a 10-J or more increase in the defibrillation energy requirement. CONCLUSION The mean defibrillation energy requirement does not change significantly after 2 years of biphasic nonthoracotomy defibrillator system implantation. However, approximately 15% of patients develop a 10-J or greater elevation in the defibrillation energy requirement, and 3% may require a defibrillation system revision. Therefore, a yearly evaluation of the defibrillation energy requirement may be appropriate.
Collapse
|
Comparative Study |
27 |
30 |
7
|
Katz SL, MacLean JE, Hoey L, Horwood L, Barrowman N, Foster B, Hadjiyannakis S, Legault L, Bendiak GN, Kirk VG, Constantin E. Insulin Resistance and Hypertension in Obese Youth With Sleep-Disordered Breathing Treated With Positive Airway Pressure: A Prospective Multicenter Study. J Clin Sleep Med 2017; 13:1039-1047. [PMID: 28728620 DOI: 10.5664/jcsm.6718] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2016] [Accepted: 06/12/2017] [Indexed: 01/30/2023]
Abstract
STUDY OBJECTIVES There is evidence that cardiometabolic disease associated with obesity and sleep-disordered breathing (SDB) in adults is present in youth. SDB is often treated with positive airway pressure (PAP) in youth with obesity. Our aims were to determine: (1) the prevalence of cardiometabolic disease and (2) whether PAP improves markers of cardiometabolic disease, in youth with obesity and newly diagnosed moderate-severe SDB. METHODS A prospective multicenter cohort study was conducted in youth (8 to 16 years old) with obesity, prescribed PAP therapy for newly diagnosed moderate-severe SDB. Assessments occurred at baseline and at 6 and 12 months. Outcomes included markers of insulin resistance (change in homeostasis model assessment of insulin resistance (HOMA-IR) at 6 months = primary outcome), hypertension (24-hour ambulatory/blood pressure) and inflammation (high-sensitivity C-reactive protein: hs-CRP). RESULTS Twenty-seven participants were enrolled. Of those with baseline testing available, 10/25 (40%) had HOMA-IR above the 97th percentile, 10/23 (44%) were hypertensive, 16/23 (70%) had loss of nocturnal blood pressure dip and hs-CRP was elevated in 16/27 (64%). There were no significant changes over time in markers of metabolic dysfunction or blood pressure, nor between PAP-adherent and non-adherent subgroups. CONCLUSIONS In youth with obesity and SDB, metabolic dysfunction and hypertension were highly prevalent. There were no statistically significant improvements in cardiometabolic markers 1 year after the prescription of PAP therapy, although clinically relevant improvements were seen in insulin resistance and systolic blood pressure load, important predictors of future risk of cardiovascular disease. Larger, longer-term studies are needed to determine whether PAP improves cardiometabolic outcomes in obese youth. COMMENTARY A commentary on this article appears in this issue on page 1025.
Collapse
|
Multicenter Study |
8 |
29 |
8
|
Strickberger SA, Niebauer M, Man KC, Daoud E, Williamson BD, Horwood L, Hummel JD, Morady F. Comparison of implantation of nonthoracotomy defibrillators in the operating room versus the electrophysiology laboratory. Am J Cardiol 1995; 75:255-7. [PMID: 7832134 DOI: 10.1016/0002-9149(95)80031-m] [Citation(s) in RCA: 25] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Implantable cardioverter-defibrillators (ICDs) with nonthoracotomy lead systems are widely available, and are implanted either in the electrophysiology laboratory or the operating room. The purpose of this study was to prospectively evaluate the safety and efficacy of nonthoracotomy ICD implantation in an electrophysiology laboratory versus an operating room. During a 7-month period, 62 consecutive ICDs with nonthoracotomy lead systems were implanted in patients in an electrophysiology laboratory. During the next 10 months, 110 consecutive ICDs were implanted in patients in a surgical operating room. All ICD implantations were performed under general anesthesia by electrophysiologists. There were no differences in age (58 +/- 14 vs 62 +/- 12 years, p = 0.06), gender distribution (p = 0.3), frequency of structural heart disease (97% vs 97%, p = 0.9), ejection fraction (0.31 +/- 0.15 vs 0.29 +/- 0.13, p = 0.3), or presentation with cardiac arrest (65% vs 53%, p = 0.2) between patients undergoing ICD implantation in the electrophysiology laboratory and operating room, respectively. The rate of successful implantation and of complications for systems implanted in the electrophysiology laboratory (95% and 13%, respectively) and in the operating room (98% and 14%, respectively) were similar (p = 0.4 and p = 0.8, respectively). Specifically, the rate of infection (0% vs 4%, p = 0.3) and hematoma formation (2% vs 4%, p = 0.8) were not statistically significantly different. Three patients who had undergone ICD implantation in an operating room died within 30 days. ICDs with nonthoracotomy lead systems can be implanted with a similarly high rate of success and acceptable complication rate in the electrophysiology laboratory and in the operating room.
Collapse
|
Clinical Trial |
30 |
25 |
9
|
Daoud EG, Niebauer M, Kou WH, Man KC, Horwood L, Morady F, Strickberger SA. Incidence of implantable defibrillator discharges after coronary revascularization in survivors of ischemic sudden cardiac death. Am Heart J 1995; 130:277-80. [PMID: 7631607 DOI: 10.1016/0002-8703(95)90440-9] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Coronary revascularization has been suggested as sole therapy for secondary prevention of sudden cardiac arrest associated with ischemia. The use of implantable defibrillators (ICD) in combination with coronary revascularization for this patient population is unclear. Among 412 consecutive patients receiving an ICD, 23 (6%) were identified as sudden cardiac arrest survivors who were noninducible with programmed stimulation and had unstable angina or ischemia on a functional study; they underwent successful coronary revascularization. During a follow-up of 34 +/- 18 months, 10 (43%) of the 23 patients received ICD shocks (8 +/- 8 per patient, range 1 to 22 shocks), and nine of the 10 patients had syncope/presyncope associated with at least one ICD discharge. Patients with ICD discharges were compared with those without ICD discharges, and no clinical characteristics were statistically different between the two groups. In conclusion, revascularization alone may be inadequate therapy for survivors of sudden cardiac arrest associated with ischemia who are noninducible with programmed stimulation, and clinical variables cannot predict which patients are likely to have recurrent malignant ventricular arrhythmias.
Collapse
|
|
30 |
21 |
10
|
Horwood L, Nguyen LHP, Brown K, Paci P, Constantin E. African American ethnicity as a risk factor for respiratory complications following adenotonsillectomy. JAMA Otolaryngol Head Neck Surg 2013; 139:147-52. [PMID: 23328981 DOI: 10.1001/jamaoto.2013.1321] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/13/2024]
Abstract
OBJECTIVE To evaluate whether African American ethnicity is a risk factor for major respiratory complications following adenotonsillectomy (T&A). DESIGN Retrospective cohort study. SETTING A Canadian tertiary care center. PATIENTS Children aged 0 to 18 years who underwent T&A at our institution from 2002 to 2006 with planned or unplanned postoperative admissions. MAIN OUTCOME MEASURES We evaluated the association between ethnicity and our main outcome measure, major perioperative respiratory complications of T&A. Parental report of ethnicity was available for 23% of our cohort. At our institution, African American children undergo a routine preoperative sickle cell test (TestSC). Data on TestSC were included for all children. We established that having a TestSC was an accurate proxy for African American ethnicity (sensitivity, 96%; specificity, 93%; positive predictive value, 77%; negative predictive value, 99%). RESULTS Seventy-four of 594 children experienced major respiratory complications (12.5%). Compared with children who did not have major respiratory complications, those who did had a TestSC (P = .01), were 2 years or younger (P < .001) and had lower weight-for-age z scores (P = .04), moderate to severe obstructive sleep apnea (P = .003), and comorbidities (P < .001). When controlling for these variables in a multivariate analysis, children of African American ethnicity (TestSC used as a proxy) were at higher risk of having major perioperative respiratory complications (adjusted odds ratio, 1.82 [95% CI 1.05-3.14]) (P = .003). CONCLUSIONS Children of African American ethnicity (TestSC used as a proxy) are nearly twice as likely to experience major respiratory complications related to T&A. Ethnicity may be an additional independent risk factor for clinicians to consider when planning for T&A.
Collapse
|
|
12 |
21 |
11
|
Horwood L, Mok E, Li P, Oskoui M, Shevell M, Constantin E. Prevalence of sleep problems and sleep-related characteristics in preschool- and school-aged children with cerebral palsy. Sleep Med 2018; 50:1-6. [DOI: 10.1016/j.sleep.2018.05.008] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/2018] [Revised: 05/10/2018] [Accepted: 05/14/2018] [Indexed: 10/16/2022]
|
|
7 |
19 |
12
|
Horwood L, Li P, Mok E, Oskoui M, Shevell M, Constantin E. Behavioral difficulties, sleep problems, and nighttime pain in children with cerebral palsy. RESEARCH IN DEVELOPMENTAL DISABILITIES 2019; 95:103500. [PMID: 31630025 DOI: 10.1016/j.ridd.2019.103500] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2019] [Revised: 08/26/2019] [Accepted: 09/27/2019] [Indexed: 06/10/2023]
Abstract
BACKGROUND Children with cerebral palsy (CP) may be at risk of behavioral difficulties. AIMS 1) Determine the prevalence of behavioral difficulties in preschool- and school-aged children with CP and 2) Assess the association between behavioral difficulties and a) sleep problems, b) nighttime pain and c) child characteristics (age, CP phenotype, comorbidities). METHODS AND PROCEDURES Caregivers of 113 children with CP aged 4-12 years [mean (SD) age = 7.4 (2.5) years; 61.9% male] completed the Strengths and Difficulties Questionnaire, Sleep Disturbance Scale for Children and a sleep quality questionnaire to assess child behavior, sleep and nighttime pain, respectively. OUTCOMES AND RESULTS 25.6% of children (17.6% preschool-aged; 29.1% school-aged) had behavioral difficulties. Sleep problems (odds ratio [OR] 9.1, 95% confidence interval [CI] 3.4-24.4) and nighttime pain (OR 4.1, 95% CI 1.5-11.5) were associated with behavioral difficulties. Sleep problems remained significantly associated with behavioral difficulties (adjusted OR 7.5, 95% CI 2.6-21.4) when adjusted for nighttime pain, age and non-ambulatory status. CONCLUSIONS AND IMPLICATIONS Behavioral difficulties were reported in one in four children with CP and were associated with sleep problems and nighttime pain. Identifying and treating behavioral difficulties, sleep problems or nighttime pain is important in the care of children with CP.
Collapse
|
|
6 |
17 |
13
|
Goyal R, Harvey M, Horwood L, Bogun F, Castellani M, Chan KK, Daoud E, Niebauer M, Man KC, Morady F, Strickberger SA. Incidence of lead system malfunction detected during implantable defibrillator generator replacement. Pacing Clin Electrophysiol 1996; 19:1143-6. [PMID: 8865211 DOI: 10.1111/j.1540-8159.1996.tb04183.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Implantable cardioverter-defibrillator (ICD) generator replacement due to a depleted battery is a frequently performed procedure. The frequency with which sensing and defibrillation system failures are identified during device replacement procedures has not been previously described. Therefore, the purpose of this study was to prospectively determine the frequency of lead system malfunction detected at the time of device replacement in 55 consecutive patients undergoing ICD generator replacement. The mean age of the patients was 63 +/- 10 years and 40 of them were men. Forty-nine patients had an epicardial lead system, and six patients had a nonthoracotomy lead system. Four [7%] of these 55 patients were noted to have previously undetected lead system failure, either sensing (n = 3) or defibrillation (n = 1), necessitating system revision. The lead systems that failed were 40 +/- 6 months old (33-49 months). In summary, during ICD generator replacement, previously undetected problems with sensing or defibrillation may be identified in approximately 10% of patients. Therefore, a comprehensive evaluation of the sensing and the defibrillation functions should be an essential component of the ICD generator replacement procedure.
Collapse
|
|
29 |
16 |
14
|
Daoud EG, Man KC, Horwood L, Morady F, Strickberger SA. Relation between amiodarone and desethylamiodarone plasma concentrations and ventricular defibrillation energy requirements. Am J Cardiol 1997; 79:97-100. [PMID: 9024750 DOI: 10.1016/s0002-9149(96)00689-3] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
The main finding of this prospective, controlled study is that amiodarone and desethylamiodarone plasma concentrations < 1 mg/L are associated with a 23% increase in the acute defibrillation energy requirement and with a 31% increase in the requirement for a subcutaneous patch or array. The defibrillation energy requirement does not correlate with the plasma concentrations of amiodarone, desethylamiodarone, amiodarone plus desethylamiodarone, or with the duration or daily dosage of amiodarone therapy.
Collapse
|
Clinical Trial |
28 |
15 |
15
|
Katz SL, Kirk VG, MacLean JE, Bendiak GN, Harrison MA, Barrowman N, Hoey L, Horwood L, Hadjiyannakis S, Legault L, Foster BJ, Constantin E. Factors related to positive airway pressure therapy adherence in children with obesity and sleep-disordered breathing. J Clin Sleep Med 2020; 16:733-741. [PMID: 32029068 DOI: 10.5664/jcsm.8336] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
STUDY OBJECTIVES Positive airway pressure (PAP) is used to treat children with concurrent obesity and sleep-disordered breathing (SDB), but achieving adherence remains challenging. We aimed to identify factors associated with PAP adherence in a prospective cohort of children with obesity prescribed PAP for newly diagnosed SDB. METHODS A questionnaire to assess factors related to PAP adherence was administered to participants and their parent ≥12 months after enrollment. Adherence (PAP use ≥4 hours/night on >50% of nights) was measured with PAP machine downloads, diaries, and physician assessments. Questionnaire responses were compared between adherent/nonadherent participants and between children/parents. Age, total and obstructive apnea-hypopnea index (OAHI), lowest oxygen saturation, and highest carbon dioxide were compared between adherent/nonadherent children with univariate differences of medians, with 95% confidence intervals. RESULTS Fourteen children (median age: 14.3 years; 93% male; all with obstructive sleep apnea) were included. Eleven (79%) were adherent to PAP. SDB symptom improvement was reported in 9 of 14 children (64%); 8 of 14 children (57%) had positive experiences with PAP. Most children assumed an active role in PAP initiation and felt supported by the clinical team. Responses between adherent/nonadherent groups and between children/parents were similar. Oxygen saturation nadir (median difference between nonadherent and adherent groups: 8.9%; 95% confidence interval: 1.7, 16.1), but not age, apnea-hypopnea index, OAHI, or maximum carbon dioxide, was associated with PAP adherence. CONCLUSIONS Children with obesity-related SDB with lower nocturnal oxygen saturation nadir were more likely to adhere to PAP therapy. Ensuring adequate understanding of PAP therapy and medical team support are key factors in PAP success.
Collapse
|
|
5 |
8 |
16
|
Thombs BD, Aguila K, Dyas L, Carrier ME, Fedoruk C, Horwood L, Cañedo-Ayala M, Sauvé M, Kwakkenbos L, Malcarne VL, El-Baalbaki G, Peláez S, Connolly K, Hudson M, Platt RW. Protocol for a partially nested randomized controlled trial to evaluate the effectiveness of the Scleroderma Patient-centered Intervention Network Support Group Leader EDucation (SPIN-SSLED) Program. Trials 2019; 20:717. [PMID: 31831073 PMCID: PMC6909446 DOI: 10.1186/s13063-019-3747-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Accepted: 09/23/2019] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND Some people with rare diseases rely on peer-led support groups for disease-specific education and emotional and practical support. Systemic sclerosis (SSc), or scleroderma, is a rare autoimmune connective tissue disease. Many people with SSc cannot access support groups, and, when support groups exist, they may not be sustained due to challenges that could be addressed via leader training. The Scleroderma Patient-centered Intervention Network (SPIN), along with SSc patient organization partners, developed a training program for SSc patient support group leaders, the Scleroderma Support group Leader EDucation (SPIN-SSLED) Program. We recently completed a feasibility trial in which we successfully delivered the program to two groups of support group leaders who reported a high level of satisfaction with the program and its delivery. The primary objective of the full-scale SPIN-SSLED trial is to evaluate the effect of the program on support group leaders' self-efficacy for carrying out their leadership role. Secondary objectives include evaluating effects on leader burnout, leader satisfaction (participation efficacy), and emotional distress. METHODS/DESIGN The SPIN-SSLED trial is a pragmatic randomized controlled trial (RCT) in which 180 support group leaders will be randomly allocated to training groups of 6 participants each or to a waitlist control. We will use a partially nested RCT design to reflect dependence between individuals in training groups, but not in the waitlist control. Participants allocated to the training program will receive the 13-module SPIN-SSLED Program, delivered via webinar over the course of 3 months in weekly 60-90-min sessions. The primary outcome is leader self-efficacy, measured by the Scleroderma Support Group Leader Self-efficacy Scale post-intervention. Secondary outcomes are leader self-efficacy at 3 months post-intervention, and leader burnout, volunteer job satisfaction (participation efficacy), and emotional distress post-intervention and at 3 months post-intervention. DISCUSSION The SPIN-SSLED trial will test whether a training program for SSc patient support group leaders increases the self-efficacy of group leaders to carry out leadership tasks. The program has the potential to significantly improve the effectiveness and sustainability of existing SSc support groups, to increase the number of available support groups, and to be adapted for other chronic diseases. TRIAL REGISTRATION ClinicalTrials.gov, NCT03965780. Registered on 29 May 2019.
Collapse
|
Clinical Trial Protocol |
6 |
7 |
17
|
Abstract
Ventricular tachycardia is the most common life-threatening tachyarrhythmia seen in patients with structural heart disease. In the past 10 years, many thousands of lives have been saved by the addition of the implantable cardioverter-defibrillator to the armamentarium of treatment options. Yet, despite the success of these devices in the prevention of sudden cardiac death, many patients felt that the psychological cost was too high. Loss or restriction of some of the most basic activities such as driving and working and not knowing when they would receive the life-saving but painful shock took a toll on patients' perceptions of the quality of their lives. When antitachycardia pacing was demonstrated to provide about half of these patients a life-saving, yet comfortable, means of controlling episodes of ventricular tachycardia, physicians and patients were eager to try it. None of the many ways to provide antitachycardia pacing has proved overwhelmingly more effective than the others. This paper describes and illustrates each type of antitachycardia pacing and demonstrates their programmed parameters. Several clinical case illustrations are included.
Collapse
|
|
30 |
5 |
18
|
Katz SL, MacLean JE, Barrowman N, Hoey L, Horwood L, Bendiak GN, Kirk VG, Hadjiyannakis S, Legault L, Foster BJ, Constantin E. Long-Term Impact of Sleep-Disordered Breathing on Quality of Life in Children With Obesity. J Clin Sleep Med 2018; 14:451-458. [PMID: 29458697 DOI: 10.5664/jcsm.6998] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2017] [Accepted: 12/18/2017] [Indexed: 11/13/2022]
Abstract
STUDY OBJECTIVES (1) To determine baseline quality of life (QOL) among children with obesity and newly diagnosed moderate-severe sleep-disordered breathing (SDB) and to compare it to the reported QOL of children with obesity or SDB alone and healthy children. (2) To evaluate QOL change after 1 year. METHODS A prospective multicenter cohort study was conducted in children (8-16 years) with obesity, prescribed positive airway pressure (PAP) therapy for moderate-severe SDB. Outcomes included parent-proxy and self-report total and subscale scores on the PedsQL questionnaire (baseline and 1-year). RESULTS Total PedsQL scores were indicative of impaired QOL in 69% of cases based on parent-report and in 62% on self-report. Parents reported significantly lower QOL in our cohort than that reported in other studies for children with obesity or SDB alone or healthy children, on total PedsQL score and on social and psychosocial subscales. PedsQL total scores for participants were significantly higher (mean difference 7.3 ± 15.3, P = .03) than those reported by parents. Parents reported significant improvements in total PedsQL (mean change 7.29 ± 13.73, P = .04) and social functioning (mean change 17.65 ± 24.69, P = .04) scores after 1 year. No significant differences were found by children's self-report or by PAP adherence. CONCLUSIONS QOL of children with obesity and SDB is lower than in children with obesity or SDB alone or healthy children. One year later, children reported no significant changes in QOL; parents reported significant improvements in total PedsQL and social functioning scores. PAP adherence did not significantly affect QOL change in this population. COMMENTARY A commentary on this article appears in this issue on page 307.
Collapse
|
Research Support, Non-U.S. Gov't |
7 |
5 |
19
|
Constantin E, MacLean J, Barrowman N, Hoey L, Horwood L, Bendiak G, Kirk V, Hadjiyannakis S, Legault L, Foster B, Katz S. Behavioral and emotional characteristics of Canadian children with obesity and moderate-severe sleep-disordered breathing treated with positive airway pressure: longitudinal changes and associations with adherence. Sleep Med 2019. [DOI: 10.1016/j.sleep.2019.11.218] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
|
6 |
1 |
20
|
Xie K, Royer J, Larivière S, Rodriguez-Cruces R, Frässle S, Cabalo DG, Ngo A, DeKraker J, Auer H, Tavakol S, Weng Y, Abdallah C, Arafat T, Horwood L, Frauscher B, Caciagli L, Bernasconi A, Bernasconi N, Zhang Z, Concha L, Bernhardt BC. Atypical connectome topography and signal flow in temporal lobe epilepsy. Prog Neurobiol 2024; 236:102604. [PMID: 38604584 DOI: 10.1016/j.pneurobio.2024.102604] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Revised: 12/18/2023] [Accepted: 04/07/2024] [Indexed: 04/13/2024]
Abstract
Temporal lobe epilepsy (TLE) is the most common pharmaco-resistant epilepsy in adults. While primarily associated with mesiotemporal pathology, recent evidence suggests that brain alterations in TLE extend beyond the paralimbic epicenter and impact macroscale function and cognitive functions, particularly memory. Using connectome-wide manifold learning and generative models of effective connectivity, we examined functional topography and directional signal flow patterns between large-scale neural circuits in TLE at rest. Studying a multisite cohort of 95 patients with TLE and 95 healthy controls, we observed atypical functional topographies in the former group, characterized by reduced differentiation between sensory and transmodal association cortices, with most marked effects in bilateral temporo-limbic and ventromedial prefrontal cortices. These findings were consistent across all study sites, present in left and right lateralized patients, and validated in a subgroup of patients with histopathological validation of mesiotemporal sclerosis and post-surgical seizure freedom. Moreover, they were replicated in an independent cohort of 30 TLE patients and 40 healthy controls. Further analyses demonstrated that reduced differentiation related to decreased functional signal flow into and out of temporolimbic cortical systems and other brain networks. Parallel analyses of structural and diffusion-weighted MRI data revealed that topographic alterations were independent of TLE-related cortical thinning but partially mediated by white matter microstructural changes that radiated away from paralimbic circuits. Finally, we found a strong association between the degree of functional alterations and behavioral markers of memory dysfunction. Our work illustrates the complex landscape of macroscale functional imbalances in TLE, which can serve as intermediate markers bridging microstructural changes and cognitive impairment.
Collapse
|
Research Support, N.I.H., Extramural |
1 |
|
21
|
Constantin E, MacLean JE, Barrowman N, Horwood L, Bendiak GN, Kirk VG, Hadjiyannakis S, Legault L, Foster BJ, Katz SL. Behavioral and emotional characteristics of Canadian children with obesity and moderate-severe sleep-disordered breathing treated with positive airway pressure: longitudinal changes and associations with adherence. J Clin Sleep Med 2023; 19:555-562. [PMID: 36541207 PMCID: PMC9978431 DOI: 10.5664/jcsm.10386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 11/02/2022] [Accepted: 11/02/2022] [Indexed: 12/24/2022]
Abstract
STUDY OBJECTIVES Behavioral characteristics and outcomes of positive airway pressure (PAP) therapy in children with obesity and moderate-severe sleep-disordered breathing (SDB) have not been reported. Our aims were to 1) determine baseline behavioral/emotional symptoms of this population and characterize changes over time with PAP, and 2) examine associations between baseline behavioral/emotional symptoms and PAP adherence. METHODS This multicenter prospective cohort study of children with obesity prescribed PAP for moderate-severe SDB assessed PAP adherence (≥ 4 h/night, >50% of nights, usage diaries, downloads) and compared behavioral/emotional characteristics with parent- and child-reported Conners Rating Scale (Conners) and the Child Behavior Checklist (CBCL) at baseline and 1 year after PAP prescription between adherent and nonadherent participants; scores at baseline were compared retrospectively between adherence groups. RESULTS Twenty-four children were included (median 14.1 years [IQR:12.4,16.0]; 87.5% males). Baseline Conners and CBCL scores were elevated (parent- and child-reported Conners inattention and hyperactivity subscales and CBCL subscales [total, internalizing, externalizing]). Baseline parent-reported Conners scores were significantly more elevated in the nonadherent than adherent group (inattention: 73.3 ± 8.5 vs 60.5 ± 14.6, P = .01; hyperactivity: 70.9 ± 11.1 vs 59.1 ± 16.0, P = .05). This difference was present 1 year later for inattention (P = .01) but not for hyperactivity (P = .09). Parent-reported CBCL scores improved over 1 year in adherent but not nonadherent participants. CONCLUSIONS We found that children with obesity and moderate-severe SDB have elevated symptoms of behavioral/emotional concerns on standardized testing. Parent-reported emotional characteristics improved in the adherent but not in the nonadherent group. Children with greater inattention/hyperactivity at baseline were less adherent to PAP, suggesting this may contribute to PAP nonadherence. CITATION Constantin E, MacLean JE, Barrowman N, et al. Behavioral and emotional characteristics of Canadian children with obesity and moderate-severe sleep-disordered breathing treated with positive airway pressure: longitudinal changes and associations with adherence. J Clin Sleep Med. 2023;19(3):555-562.
Collapse
|
Multicenter Study |
2 |
|
22
|
Xie K, Royer J, Rodriguez‐Cruces R, Horwood L, Ngo A, Arafat T, Auer H, Sahlas E, Chen J, Zhou Y, Valk SL, Hong S, Frauscher B, Pana R, Bernasconi A, Bernasconi N, Concha L, Bernhardt BC. Temporal Lobe Epilepsy Perturbs the Brain-Wide Excitation-Inhibition Balance: Associations with Microcircuit Organization, Clinical Parameters, and Cognitive Dysfunction. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2025; 12:e2406835. [PMID: 39806576 PMCID: PMC11884548 DOI: 10.1002/advs.202406835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2024] [Revised: 10/23/2024] [Indexed: 01/16/2025]
Abstract
Excitation-inhibition (E/I) imbalance is theorized as a key mechanism in the pathophysiology of epilepsy, with ample research focusing on elucidating its cellular manifestations. However, few studies investigate E/I imbalance at the macroscale, whole-brain level, and its microcircuit-level mechanisms and clinical significance remain incompletely understood. Here, the Hurst exponent, an index of the E/I ratio, is computed from resting-state fMRI time series, and microcircuit parameters are simulated using biophysical models. A broad decrease in the Hurst exponent is observed in pharmaco-resistant temporal lobe epilepsy (TLE), suggesting more excitable network dynamics. Connectome decoders point to temporolimbic and frontocentral cortices as plausible network epicenters of E/I imbalance. Furthermore, computational simulations reveal that enhancing cortical excitability in TLE reflects atypical increases in recurrent connection strength of local neuronal ensembles. Mixed cross-sectional and longitudinal analyses show stronger E/I ratio elevation in patients with longer disease duration, more frequent electroclinical seizures as well as interictal epileptic spikes, and worse cognitive functioning. Hurst exponent-informed classifiers discriminate patients from healthy controls with high accuracy (72.4% [57.5%-82.5%]). Replicated in an independent dataset, this work provides in vivo evidence of a macroscale shift in E/I balance in TLE patients and points to progressive functional imbalances that relate to cognitive decline.
Collapse
|
research-article |
1 |
|
23
|
Horwood L, VanRiper S, Davidson T. Antitachycardia pacing: an overview. Am J Crit Care 1995; 4:397-404. [PMID: 7489045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
Ventricular tachycardia is the most common life-threatening tachyarrhythmia seen in patients with structural heart disease. In the past 10 years, many thousands of lives have been saved by the addition of the implantable cardioverter-defibrillator to the armamentarium of treatment options. Yet, despite the success of these devices in the prevention of sudden cardiac death, many patients felt that the psychological cost was too high. Loss or restriction of some of the most basic activities such as driving and working and not knowing when they would receive the life-saving but painful shock took a toll on patients' perceptions of the quality of their lives. When antitachycardia pacing was demonstrated to provide about half of these patients a life-saving, yet comfortable, means of controlling episodes of ventricular tachycardia, physicians and patients were eager to try it. None of the many ways to provide antitachycardia pacing has proved overwhelmingly more effective than the others. This paper describes and illustrates each type of antitachycardia pacing and demonstrates their programmed parameters. Several clinical case illustrations are included.
Collapse
|
Case Reports |
30 |
|
24
|
Prisciandaro J, Fox C, Horwood L, Hayman J, Makkar A, Moran J, Pelosi F. SU-E-T-183: Managing and Assessing Patients Receiving Radiotherapy with Implantable Cardiac Devices. Med Phys 2012; 39:3745. [DOI: 10.1118/1.4735242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
|
13 |
|
25
|
Xie K, Royer J, Larivière S, Rodriguez-Cruces R, Frässle S, Cabalo DG, Ngo A, DeKraker J, Auer H, Tavakol S, Weng Y, Abdallah C, Horwood L, Frauscher B, Caciagli L, Bernasconi A, Bernasconi N, Zhang Z, Concha L, Bernhardt BC. Atypical connectome topography and signal flow in temporal lobe epilepsy. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.05.23.541934. [PMID: 37292996 PMCID: PMC10245853 DOI: 10.1101/2023.05.23.541934] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Temporal lobe epilepsy (TLE) is one of the most common pharmaco-resistant epilepsies in adults. While hippocampal pathology is the hallmark of this condition, emerging evidence indicates that brain alterations extend beyond the mesiotemporal epicenter and affect macroscale brain function and cognition. We studied macroscale functional reorganization in TLE, explored structural substrates, and examined cognitive associations. We investigated a multisite cohort of 95 patients with pharmaco-resistant TLE and 95 healthy controls using state-of-the-art multimodal 3T magnetic resonance imaging (MRI). We quantified macroscale functional topographic organization using connectome dimensionality reduction techniques and estimated directional functional flow using generative models of effective connectivity. We observed atypical functional topographies in patients with TLE relative to controls, manifesting as reduced functional differentiation between sensory/motor networks and transmodal systems such as the default mode network, with peak alterations in bilateral temporal and ventromedial prefrontal cortices. TLE-related topographic changes were consistent in all three included sites and reflected reductions in hierarchical flow patterns between cortical systems. Integration of parallel multimodal MRI data indicated that these findings were independent of TLE-related cortical grey matter atrophy, but mediated by microstructural alterations in the superficial white matter immediately beneath the cortex. The magnitude of functional perturbations was robustly associated with behavioral markers of memory function. Overall, this work provides converging evidence for macroscale functional imbalances, contributing microstructural alterations, and their associations with cognitive dysfunction in TLE.
Collapse
|
Preprint |
2 |
|