1
|
Magnetic microspheres enhanced peanut structure cascaded lasso shaped fiber laser biosensor for cancer marker-CEACAM5 detection in serum. Talanta 2024; 271:125625. [PMID: 38244308 DOI: 10.1016/j.talanta.2024.125625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Revised: 12/30/2023] [Accepted: 01/03/2024] [Indexed: 01/22/2024]
Abstract
The detection of trace cancer markers in body fluids such as blood/serum is crucial for cancer diseases screening and treatment, which requires high sensitivity and specificity of biosensors. In this study, a peanut structure cascaded lasso (PSCL) shaped fiber sensing probe based on fiber laser demodulation method was proposed to specifically detect the carcinoembryonic antigen related cell adhesion molecules 5 (CEACAM5) protein in serum. Thanks for the narrow linewidth and high signal-to-noise ratio (SNR) of the laser spectrum, it is easier to distinguish small spectral changes than interference spectrum. Adding the antibody modified magnetic microspheres (MMS) to form the sandwich structure of "antibody-antigen-antibody-MMS", and amplified the response caused by biomolecular binding. The limit of detection (LOD) for CEACAM5 in buffer could reach 0.11 ng/mL. Considering the common threshold of 5 ng/mL for CEA during medical screening and the cut off limit of 2.5 ng/mL for some kits, the LOD of proposed biosensor meets the actual needs. Human serum samples from a hospital were used to validate the real sensing capability of proposed biosensor. The deviation between the measured value in various serum samples and the clinical value ranged from 1.9 to 9.8 %. This sensing scheme holds great potential to serve as a point of care testing (POCT) device and extend to more biosensing applications.
Collapse
|
2
|
Three-dimensional pseudo-continuous arterial spin-labelled perfusion imaging for diagnosing upper cervical lymph node metastasis in patients with nasopharyngeal carcinoma: a whole-node histogram analysis. Clin Radiol 2024; 79:e736-e743. [PMID: 38341343 DOI: 10.1016/j.crad.2024.01.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 01/11/2024] [Accepted: 01/16/2024] [Indexed: 02/12/2024]
Abstract
AIM To evaluate whole-node histogram parameters of blood flow (BF) maps derived from three-dimensional pseudo-continuous arterial spin-labelled (3D pCASL) imaging in discriminating metastatic from benign upper cervical lymph nodes (UCLNs) for nasopharyngeal carcinoma (NPC) patients. MATERIALS AND METHODS Eighty NPC patients with a total of 170 histologically confirmed UCLNs (67 benign and 103 metastatic) were included retrospectively. Pre-treatment 3D pCASL imaging was performed and whole-node histogram analysis was then applied. Histogram parameters and morphological features, such as minimum axis diameter (MinAD), maximum axis diameter (MaxAD), and location of UCLNs, were assessed and compared between benign and metastatic lesions. Predictors were identified and further applied to establish a combined model by multivariate logistic regression in predicting the probability of metastatic UCLNs. Receiver operating characteristic (ROC) curves were used to analyse the diagnostic performance. RESULTS Metastatic UCLNs had larger MinAD and MinAD/MaxAD ratio, greater energy and entropy values, and higher incidence of level II (upper jugular group), but lower BF10th value than benign nodes (all p<0.05). MinAD, BF10th, energy, and entropy were validated as independent predictors in diagnosing metastatic UCLNs. The combined model yielded an area under the curve (AUC) of 0.932, accuracy of 84.42 %, sensitivity of 80.6 %, and specificity of 90.29 %. CONCLUSIONS Whole-node histogram analysis on BF maps is a feasible tool to differentiate metastatic from benign UCLNs in NPC patients, and the combined model can further improve the diagnostic efficacy.
Collapse
|
3
|
Measurements of All-Particle Energy Spectrum and Mean Logarithmic Mass of Cosmic Rays from 0.3 to 30 PeV with LHAASO-KM2A. PHYSICAL REVIEW LETTERS 2024; 132:131002. [PMID: 38613275 DOI: 10.1103/physrevlett.132.131002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 01/23/2024] [Accepted: 02/12/2024] [Indexed: 04/14/2024]
Abstract
We present the measurements of all-particle energy spectrum and mean logarithmic mass of cosmic rays in the energy range of 0.3-30 PeV using data collected from LHAASO-KM2A between September 2021 and December 2022, which is based on a nearly composition-independent energy reconstruction method, achieving unprecedented accuracy. Our analysis reveals the position of the knee at 3.67±0.05±0.15 PeV. Below the knee, the spectral index is found to be -2.7413±0.0004±0.0050, while above the knee, it is -3.128±0.005±0.027, with the sharpness of the transition measured with a statistical error of 2%. The mean logarithmic mass of cosmic rays is almost heavier than helium in the whole measured energy range. It decreases from 1.7 at 0.3 PeV to 1.3 at 3 PeV, representing a 24% decline following a power law with an index of -0.1200±0.0003±0.0341. This is equivalent to an increase in abundance of light components. Above the knee, the mean logarithmic mass exhibits a power law trend towards heavier components, which is reversal to the behavior observed in the all-particle energy spectrum. Additionally, the knee position and the change in power-law index are approximately the same. These findings suggest that the knee observed in the all-particle spectrum corresponds to the knee of the light component, rather than the medium-heavy components.
Collapse
|
4
|
[Preliminary study on automatic quantification and grading of leopard spots fundus based on deep learning technology]. [ZHONGHUA YAN KE ZA ZHI] CHINESE JOURNAL OF OPHTHALMOLOGY 2024; 60:257-264. [PMID: 38462374 DOI: 10.3760/cma.j.cn112142-20231210-00281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 03/12/2024]
Abstract
Objective: To achieve automatic segmentation, quantification, and grading of different regions of leopard spots fundus (FT) using deep learning technology. The analysis includes exploring the correlation between novel quantitative indicators, leopard spot fundus grades, and various systemic and ocular parameters. Methods: This was a cross-sectional study. The data were sourced from the Beijing Eye Study, a population-based longitudinal study. In 2001, a group of individuals aged 40 and above were surveyed in five urban communities in Haidian District and three rural communities in Daxing District of Beijing. A follow-up was conducted in 2011. This study included individuals aged 50 and above who participated in the second 5-year follow-up in 2011, considering only the data from the right eye. Color fundus images centered on the macula of the right eye were input into the leopard spot segmentation model and macular detection network. Using the macular center as the origin, with inner circle diameters of 1 mm, 3 mm, and outer circle diameter of 6 mm, fine segmentation of the fundus was achieved. This allowed the calculation of the leopard spot density (FTD) and leopard spot grade for each region. Further analyses of the differences in ocular and systemic parameters among different regions' FTD and leopard spot grades were conducted. The participants were categorized into three refractive types based on equivalent spherical power (SE): myopia (SE<-0.25 D), emmetropia (-0.25 D≤SE≤0.25 D), and hyperopia (SE>0.25 D). Based on axial length, the participants were divided into groups with axial length<24 mm, 24-26 mm, and>26 mm for the analysis of different types of FTD. Statistical analyses were performed using one-way analysis of variance, Kruskal-Wallis test, Bonferroni test, and Spearman correlation analysis. Results: The study included 3 369 participants (3 369 eyes) with an average age of (63.9±10.6) years; among them, 1 886 were female (56.0%) and 1, 483 were male (64.0%). The overall FTD for all eyes was 0.060 (0.016, 0.163); inner circle FTD was 0.000 (0.000, 0.025); middle circle FTD was 0.030 (0.000, 0.130); outer circle FTD was 0.055 (0.009, 0.171). The results of the univariate analysis indicated that FTD in various regions was correlated with axial length (overall: r=0.38, P<0.001; inner circle: r=0.31, P<0.001; middle circle: r=0.36, P<0.001; outer circle: r=0.39, P<0.001), subfoveal choroidal thickness (SFCT) (overall: r=-0.69, P<0.001; inner circle: r=-0.57, P<0.001; middle circle: r=-0.68, P<0.001; outer circle: r=-0.72, P<0.001), age (overall: r=0.34, P<0.001; inner circle: r=0.30, P<0.001; middle circle: r=0.31, P<0.001; outer circle: r=0.35, P<0.001), gender (overall: r=-0.11, P<0.001; inner circle: r=-0.04, P<0.001; middle circle: r=-0.07, P<0.001; outer circle: r=-0.11, P<0.001), SE (overall: r=-0.20; P<0.001; inner circle: r=-0.19, P<0.001; middle circle: r=-0.20, P<0.001; outer circle: r=-0.20, P<0.001), uncorrected visual acuity (overall: r=-0.18, P<0.001; inner circle: r=-0.26, P<0.001; middle circle: r=-0.24, P<0.001; outer circle: r=-0.22, P<0.001), and body mass index (BMI) (overall: r=-0.11, P<0.001; inner circle: r=-0.13, P<0.001; middle circle: r=-0.14, P<0.001; outer circle: r=-0.13, P<0.001). Further multivariate analysis results indicated that different region FTD was correlated with axial length (overall: β=0.020, P<0.001; inner circle: β=-0.022, P<0.001; middle circle: β=0.027, P<0.001; outer circle: β=0.022, P<0.001), SFCT (overall: β=-0.001, P<0.001; inner circle: β=-0.001, P<0.001; middle circle: β=-0.001, P<0.001; outer circle: β=-0.001, P<0.001), and age (overall: β=0.002, P<0.001; inner circle: β=0.001, P<0.001; middle circle: β=0.002, P<0.001; outer circle: β=0.002, P<0.001). The distribution of overall (H=56.76, P<0.001), inner circle (H=72.22, P<0.001), middle circle (H=75.83, P<0.001), and outer circle (H=70.34, P<0.001) FTD differed significantly among different refractive types. The distribution of overall (H=373.15, P<0.001), inner circle (H=367.67, P<0.001), middle circle (H=389.14, P<0.001), and outer circle (H=386.89, P<0.001) FTD differed significantly among different axial length groups. Furthermore, comparing various levels of FTD with systemic and ocular parameters, significant differences were found in axial length (F=142.85, P<0.001) and SFCT (F=530.46, P<0.001). Conclusions: The use of deep learning technology enables automatic segmentation and quantification of different regions of theFT, as well as preliminary grading. Different region FTD is significantly correlated with axial length, SFCT, and age. Individuals with older age, myopia, and longer axial length tend to have higher FTD and more advanced FT grades.
Collapse
|
5
|
[Emphasizing the timing and procedure selection for vitrectomy in pathological myopic traction maculopathy]. [ZHONGHUA YAN KE ZA ZHI] CHINESE JOURNAL OF OPHTHALMOLOGY 2024; 60:211-214. [PMID: 38462367 DOI: 10.3760/cma.j.cn112142-20231221-00299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 03/12/2024]
Abstract
Myopic maculopathy is the primary cause of irreversible visual impairment in patients with pathologic myopia, and myopic traction maculopathy often requires vitrectomy for treatment. Myopic traction maculopathy encompasses epiretinal membrane, foveoschisis, macular hole, and macular hole-related retinal detachment. It is recommended to perform vitrectomy combined with inner limiting membrane peeling for Type II epiretinal membrane, foveal-sparing inner limiting membrane peeling for foveoschisis, inverted inner limiting membrane flap technique for macular hole, and vitrectomy combined with macular buckle for refractory macular hole-related retinal detachment. Myopic traction maculopathy is a chronically progressive condition, and surgeons need to accurately determine the timing of surgery and choose appropriate procedures to maximize the benefits for patients.
Collapse
|
6
|
Objective Neurophysiological Indices for the Assessment of Chronic Tinnitus Based on EEG Microstate Parameters. IEEE Trans Neural Syst Rehabil Eng 2024; 32:983-993. [PMID: 38376977 DOI: 10.1109/tnsre.2024.3367982] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2024]
Abstract
Chronic tinnitus is highly prevalent but lacks precise diagnostic or effective therapeutic standards. Its onset and treatment mechanisms remain unclear, and there is a shortage of objective assessment methods. We aim to identify abnormal neural activity and reorganization in tinnitus patients and reveal potential neurophysiological markers for objectively evaluating tinnitus. By way of analyzing EEG microstates, comparing metrics under three resting states (OE, CE, and OECEm) between tinnitus sufferers and controls, and correlating them with tinnitus symptoms. This study reflected specific changes in the EEG microstates of tinnitus patients across multiple resting states, as well as inconsistent correlations with tinnitus symptoms. Microstate parameters were significantly different when patients were in OE and CE states. Specifically, the occurrence of Microstate A and the transition probabilities (TP) from other Microstates to A increased significantly, particularly in the CE state (32-37%, p ≤ 0.05 ); and both correlated positively with the tinnitus intensity. Nevertheless, under the OECEm state, increases were mainly observed in the duration, coverage, and occurrence of Microstate B (15-47%, ), which negatively correlated with intensity ( [Formula: see text]-0.513, ). Additionally, TPx between Microstates C and D were significantly reduced and positively correlated with HDAS levels ( [Formula: see text] 0.548, ). Furthermore, parameters of Microstate D also correlated with THI grades ( [Formula: see text]-0.576, ). The findings of this study could offer compelling evidence for central neural reorganization associated with chronic tinnitus. EEG microstate parameters that correlate with tinnitus symptoms could serve as neurophysiological markers, contributing to future research on the objective assessment of tinnitus.
Collapse
|
7
|
[Research progress on pathogenesis of thrombocytopenia associated with TAVI]. ZHONGHUA XIN XUE GUAN BING ZA ZHI 2024; 52:205-209. [PMID: 38326074 DOI: 10.3760/cma.j.cn112148-20231007-00211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/09/2024]
|
8
|
A Multimode Microfiber Specklegram Biosensor for Measurement of CEACAM5 through AI Diagnosis. BIOSENSORS 2024; 14:57. [PMID: 38275310 PMCID: PMC10813308 DOI: 10.3390/bios14010057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2023] [Revised: 01/19/2024] [Accepted: 01/19/2024] [Indexed: 01/27/2024]
Abstract
Carcinoembryonic antigen (CEACAM5), as a broad-spectrum tumor biomarker, plays a crucial role in analyzing the therapeutic efficacy and progression of cancer. Herein, we propose a novel biosensor based on specklegrams of tapered multimode fiber (MMF) and two-dimensional convolutional neural networks (2D-CNNs) for the detection of CEACAM5. The microfiber is modified with CEA antibodies to specifically recognize antigens. The biosensor utilizes the interference effect of tapered MMF to generate highly sensitive specklegrams in response to different CEACAM5 concentrations. A zero mean normalized cross-correlation (ZNCC) function is explored to calculate the image matching degree of the specklegrams. Profiting from the extremely high detection limit of the speckle sensor, variations in the specklegrams of antibody concentrations from 1 to 1000 ng/mL are measured in the experiment. The surface sensitivity of the biosensor is 0.0012 (ng/mL)-1 within a range of 1 to 50 ng/mL. Moreover, a 2D-CNN was introduced to solve the problem of nonlinear detection surface sensitivity variation in a large dynamic range, and in the search for image features to improve evaluation accuracy, achieving more accurate CEACAM5 monitoring, with a maximum detection error of 0.358%. The proposed fiber specklegram biosensing scheme is easy to implement and has great potential in analyzing the postoperative condition of patients.
Collapse
|
9
|
Compact optical fiber sensor based on Vernier effect with speckle patterns. OPTICS EXPRESS 2023; 31:36940-36951. [PMID: 38017833 DOI: 10.1364/oe.505104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Accepted: 09/29/2023] [Indexed: 11/30/2023]
Abstract
We propose a Vernier effect-based sensor for temperature and salinity measurements. This sensor utilizes the correlation speckle pattern generated by spatial multimode interference and has undergone testing to validate its effectiveness. The speckle demodulation method is used to solve the problem of inconsistent envelope measurement when tracking with different upper and lower envelopes. The device consists of two Fabry Perot interferometers (FPIs) created by connecting hole core fiber (HCF) and erbium-doped fiber (EDF) in series. The speckle image produced by the interferometers is analyzed using the Zero means normalized cross-correlation (ZNCC) technique. The ZNCC value demonstrates a linear relationship with salinity and temperature, allowing for the measurement of these parameters. The sensor exhibits a temperature detection sensitivity of -0.0224 /°C and a salinity detection sensitivity of -0.0439/%. The sensor offers several advantageous features, including its compact size, low-cost manufacturing, high sensitivity, stability, and convenient reflection measurements. These characteristics make it a valuable tool for various applications. The proposed Vernier effect-based temperature and salinity sensor shows great potential for simultaneous monitoring and measurement of temperature and salinity in environments such as marine settings or industrial processes where accurate control of these parameters is crucial.
Collapse
|
10
|
Measurement of Ultra-High-Energy Diffuse Gamma-Ray Emission of the Galactic Plane from 10 TeV to 1 PeV with LHAASO-KM2A. PHYSICAL REVIEW LETTERS 2023; 131:151001. [PMID: 37897763 DOI: 10.1103/physrevlett.131.151001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 07/08/2023] [Accepted: 08/18/2023] [Indexed: 10/30/2023]
Abstract
The diffuse Galactic γ-ray emission, mainly produced via interactions between cosmic rays and the interstellar medium and/or radiation field, is a very important probe of the distribution, propagation, and interaction of cosmic rays in the Milky Way. In this Letter, we report the measurements of diffuse γ rays from the Galactic plane between 10 TeV and 1 PeV energies, with the square kilometer array of the Large High Altitude Air Shower Observatory (LHAASO). Diffuse emissions from the inner (15°10 TeV). The energy spectrum in the inner Galaxy regions can be described by a power-law function with an index of -2.99±0.04, which is different from the curved spectrum as expected from hadronic interactions between locally measured cosmic rays and the line-of-sight integrated gas content. Furthermore, the measured flux is higher by a factor of ∼3 than the prediction. A similar spectrum with an index of -2.99±0.07 is found in the outer Galaxy region, and the absolute flux for 10≲E≲60 TeV is again higher than the prediction for hadronic cosmic ray interactions. The latitude distributions of the diffuse emission are consistent with the gas distribution, while the longitude distributions show clear deviation from the gas distribution. The LHAASO measurements imply that either additional emission sources exist or cosmic ray intensities have spatial variations.
Collapse
|
11
|
Evaluation of Treatment Interruptions and Recovery during Biology-Guided Radiotherapy Delivery. Int J Radiat Oncol Biol Phys 2023; 117:e722-e723. [PMID: 37786107 DOI: 10.1016/j.ijrobp.2023.06.2233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
PURPOSE/OBJECTIVE(S) A Biology-guided Radiotherapy (BgRT) based device is designed to use Positron Emission Tomography (PET) signals to achieve tracked dose delivery. The goal of this study is to investigate the dose delivery accuracy in case of interruption during BgRT treatment, and resumption in a separate treatment session for a multi-target delivery, as the PET activity continues to decay. MATERIALS/METHODS A custom-built large anthropomorphic phantom (LAP) including a 26 mm spherical target with 3D independent motion and two 22 mm spherical targets with 1D sinusoidal motion embedded in water was used. All three targets were filled with FGD in an 8:1 target to background uptake ratio (41.52 kBq/ml in target and 5.19 kBq/ml in background). During BgRT delivery, the treatment was intentionally paused during delivery to the second target and the current treatment session was ended to generate a partial fraction. Then the partial fraction was continued in a new session, where the CT scan localization and PET pre-scan were repeated using the existing PET activity present in the phantom. The newly acquired PET pre-scan, was then used to determine if sufficient PET counts were present to resume treatment delivery. The interruption and recovery algorithm is designed to calculate the fluence that needs to be delivered to the remaining targets as well as the residual fluence to be given to the targets that have already received partial dose prior to the interruption. Once the new fluence is recomputed, the treatment is resumed. The delivered doses were captured using radiochromic film (EBT-XD) inserted in the target as well as post-treatment dose calculations based on the delivered beamlet sequence to evaluate the results in terms of dosimetric coverage and margin loss. The margin loss is calculated as the maximum difference between the distance from the Clinical Target Volume (CTV) contour to the 97% isodose contour in the treatment plan and the on the film. The dosimetric coverage is defined as the percentage of voxels within the CTV that lies within 97% and 130% of the prescribed dose. RESULTS As shown in the table below, a margin loss of less than 3 mm for all targets and 100% CTV coverage was achieved. After treatment interruptions, the PET safety evaluation based on the PET pre-scan helped to determine whether the treatment could be continued on the same day using the same injected PET activity (an NTS value ≧ 2 and AC value ≧ 5 kBq/ml). CONCLUSION This study demonstrated that the BgRT system is able to deliver the prescribed dose to all targets with independent motion, even when an interruption and resumption occurs during treatment. In case such an interruption if the remaining PET activity satisfies the BgRT safety evaluation, the treatment can continue to deliver the remainder of the BgRT doses.
Collapse
|
12
|
Intrafraction Dosimetric Evaluation of Biology-Guided Radiotherapy to a Target Under Respiratory Motion. Int J Radiat Oncol Biol Phys 2023; 117:e680-e681. [PMID: 37786004 DOI: 10.1016/j.ijrobp.2023.06.2141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
PURPOSE/OBJECTIVE(S) To evaluate the reproducibility and variability of biology-guided radiotherapy (BgRT) treatments using a large anthropomorphic phantom modeling the motion amplitude of a lung tumor. MATERIALS/METHODS RefleXion X1 is equipped with two opposing 90 degrees PET detector arcs to capture the radionuclide emissions and direct the 6MV Linac to treat the lesions in real time. A custom-built phantom filled with a liquid [¹⁸F]Fluorodeoxyglucose (FDG) solution was used. Fillable target and OAR structures were 3D printed and attached to motion stages. The GTV = CTV was matched to the spherical 22 mm diameter target, and the PTV was a 5 mm expansion from the CTV volume. The Biology Tracking Zone (BTZ) was generated after adding 5 mm margin to the motion extent of the CTV. The OAR was a large C-shape annulus (emulating a heart) that was approximately 3 cm from the target. The 3D independent motion trajectory of the target was designed to mimic lung motion: range of +5.8 mm to -4.9 mm in LR, range of +14.4 mm to -11.3 mm in SI, and range of +5.2 mm to -5.1 mm in AP directions. The OAR motion waveform used a 1D sinusoidal pattern with a 5 mm amplitude in SI direction. The target and the OAR were filled with 40 kBq/mL while the background had 5 kBq/mL FDG. A BgRT Modeling (imaging-only) PET acquisition was performed using RefleXion X1 and used to generate a 4-fraction BgRT treatment plan prescribing 10 Gy/fraction to PTV. For each delivery, target, OAR and background were filled with the same FDG concentrations as in the BgRT Modeling PET planning scan. Dosimetry to the target and OAR were both measured using an ion-chamber (Exradin A14SL) and film in the coronal plane through the center of the GTV for all 4 fractions. RESULTS The mean activity concentration within the (BTZ) was 7.4 ± 0.8 kBq/mL. The calculated signal-to-noise ratio metric (Normalized Target Signal) within the BTZ was 4.0 ± 0.3. Total treatment times were all less than 35 minutes (34.3 ± 0.2). Prescription dose coverage to the CTV for all 4 fractions was 100%. Ion chamber measurements in the CTV were -1.6 ± 1.3% relative to the planned dose over the active area of the ion-chamber. Minimum and maximum doses to the CTV, measured on film, were -7.7 ± 2.2% and 1.3 ± 1.4%, calculated relative to the planned dose distribution, respectively. The OAR maximum point dose measured on film was -8.7 ± 2.9%, calculated relative to the maximum OAR dose predicted on the bounded dose-volume histogram. CONCLUSION Based on this initial study, accurate and reproducible dosimetry can be achieved for targets under respiratory motion using biology-guided radiotherapy over the course of a complete course of treatment. Further studies are needed to evaluate the intrafraction dosimetry of BgRT delivery under various motion models and tumor sizes.
Collapse
|
13
|
Dosimetric Accuracy of Multi-Target Biology-Guided Radiotherapy Treatments in a Single Session. Int J Radiat Oncol Biol Phys 2023; 117:e722. [PMID: 37786108 DOI: 10.1016/j.ijrobp.2023.06.2232] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
PURPOSE/OBJECTIVE(S) We present the first dosimetric measurements of single session, multi-target BgRT deliveries using a clinically realistic motion phantom on a research-only version of the RefleXion X1 system. MATERIALS/METHODS A custom-made anthropomorphic phantom of a human torso with embedded fillable targets mimicking 18F-FDG-avid lesions was used. From the three embedded spherical targets, Target 1 was 26 mm in diameter coupled with a 3D independent respiratory motion with 22 mm range, whereas Target 2 and 3 were 22 mm in diameter and moved with a 1D 5 mm maximum sinusoidal motion. The 18F-FDG concentration in the background cavity of the phantom was 5 kBq/ml, and the targets were loaded with 10:1, 8:1 and 6:1 contrast relative to the background for Targets 1, 2, 3, respectively. Spherical structures were contoured as GTVs (CTV = GTV) and a 5 mm margin was added to create PTVs. Motion extent of the tumors were captured to create biological tracking zones for each target. Treatment plans were generated using a research version of the Reflexion treatment planning software to deliver 8 Gy/fx to the PTVs. The treatment delivery was repeated 2 times, and each time the phantom was refilled according to the plan. PET image evaluation metrics for each of the three targets were also recorded. Target dosimetry was measured using a combination of radiographic film and ion chamber. The maximum distance between the 97% prescription isodose line from the plan and the film measurements was used to characterize the dosimetric accuracy of the tracked deliveries. CTV and PTV min, max, and mean doses measured on film were also recorded for each target. RESULTS Treatment plans were successfully created with 100% prescription dose coverage to each target loaded with different FDG ratios. Total treatment times for the single-plan, three-target deliveries were less than 80 minutes. PET evaluation metrics at imaging-only and pre-scan, and planning and film dosimetry to the GTV and PTV for each of the three targets is shown in table below (mean ± standard deviation of both deliveries). The CTV dose coverage was maintained for all targets. The shrinkage distance of the 97% prescription dose isodose line on the film plane for all three targets was less than 3 mm for both tests, and ranged from -0.4 to -2.34 mm. CONCLUSION These results demonstrate that high tracking accuracy and dosimetric accuracy can be achieved in single session, multi-target deliveries over a range of target-to-background 18F-FDG concentrations and target motion patterns.
Collapse
|
14
|
Treatment Plan Creation and Delivery with and without BgRT for Static and Motion Trajectories. Int J Radiat Oncol Biol Phys 2023; 117:e697-e698. [PMID: 37786043 DOI: 10.1016/j.ijrobp.2023.06.2179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
PURPOSE/OBJECTIVE(S) In this work we try to validate the motion tracking capabilities of BgRT for periodic and step motion trajectories. SBRT plans that matches the corresponding BgRT plans are created and delivered to the same phantom with and without motion and results are evaluated. Using BgRT based SBRT plans eliminates any user bias and creates SBRT plans that would represent treatment delivery scenarios that could have happened if the PET guided BgRT was not present for that treatment. MATERIALS/METHODS To validate SBRT plans that matches the BgRT plans, we used three different types of motion patterns (1) static, (2) lung tumor motion and (3) one-centimeter step-shift. The lung tumor motion (∼25 mm in IEC-Y, ∼7 mm in IEC-X and ∼ 10 mm in IEC-Z) was used as it represents a continuous motion of the target for the entire length of the study while the step-shift case corresponds to the patient or tumor shifting between the localization CT and the start of treatment. First, a 10 Gy per fraction BgRT plan was created for each of the three experiments based on the corresponding PET image. Then, the BgRT plans were delivered to the corresponding targets with and without motion and results are evaluated. To perform a comparative study that assess the performance of BgRT and traditional SBRT (planning and delivery methods), the exact same plan fluence of BgRT plan for each experiment was used to create the corresponding SBRT plans. The newly created SBRT plans were delivered to the corresponding phantom experiments and were compared against BgRT delivery in terms of dose coverage and target margin loss using radiochromic film that moves with the target. The margin loss was calculated as the difference between the distance from the CTV contour to the 97% isodose contour in the treatment plan and the CTV contour to the 97% isodose contour on the film. Dosimetric coverage was on the other hand calculated as the percentage of the voxels within the CTV that lies within 97% and 130% of the prescribed dose. RESULTS The results showed that the margin loss for BgRT is less than 3 mm, while for the SBRT plans were more than 3 mm when target motion is present. The dosimetric coverage for BgRT was 100% for all three cases, however less than 100% for the SBRT cases with motion. Table showing margin loss for the various experiments for a prescription dose of 10 Gy. CONCLUSION The results shows that BgRT is capable of tracking the tumor motion and delivering the prescribed dose to the moving target.
Collapse
|
15
|
Characterization of Biology-Guided Radiotherapy Accuracy as a Function of PET Tracer Uptake. Int J Radiat Oncol Biol Phys 2023; 117:e668-e669. [PMID: 37785972 DOI: 10.1016/j.ijrobp.2023.06.2113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
PURPOSE/OBJECTIVE(S) To characterize the tracking capability and dosimetric accuracy of biology-guided radiotherapy (BgRT) under clinically relevant PET tracer uptake scenarios relative to the background. MATERIALS/METHODS A custom-made anthropomorphic phantom filled with a liquid 18F-FDG solution including two embedded fillable 22 mm diameter spherical structures mimicking GTV (= CTV) and OAR was coupled to motion stages to create an independent 3D respiratory motion with 22 mm maximum range for target and a 5 mm 1D sinusoidal motion in the OAR. The biology-tracking zone (BTZ) was generated by adding 5 mm margin to the motion extent. The three BgRT scenarios studied were representative of tumors with good (8:1), borderline (4:1) and undesired (2:1) PET biodistributions compared to background. The clinical safety limit of BgRT uses Activity Concentration within the BTZ (AC ≥ 5 kBq/ml) and Normalized Target Signal as a contrast metric (NTS ≧ 2.7 for planning and ≧ 2 for delivery). The BgRT deliveries were repeated 3 times with radiochromic film and integrated ion chamber capturing the target and OAR doses. Tracked dosimetry was assessed using a margin-loss calculation defined as the maximum linear difference in distance between the planned and delivered 97% prescription iso-dose lines. RESULTS The imaging-only PET images used to create BgRT plans had an AC of 7.0, 5.3, and 1.6 kBq/ml with an NTS of 6.8, 5.3, and 1.8 for 8:1, 4:1, and 2:1 concentrations, respectively. Qualitatively, the target was not visible on the planning PET images 2:1 loading scenario. At delivery, the mean pre-scan activity concentrations were 6.8, 4.7, and 3.7 kBq/ml with corresponding mean NTS of 3.7, 2.6, 1.5 for 8:1, 4:1 and 2:1 deliveries. The pre-scan values of AC or NTS did not satisfy the clinical system safety limits for 4:1 and 2:1 ratio experiments, but the engineering software allowed for the delivery to capture the resulting doses. The deliveries showed a prescription dose coverage to the CTV of 100% for the 8:1 and 4:1 cases, but 88% for the 2:1 case. When compared to the planned dose values, the delivered minimum doses were -7.6%, -8.6% and -10.9%, whereas the maximum dose differences in CTV were 1.2%, 0% and -4.8% of the planned dose distributions of the 8:1, 4:1 and 2:1 cases, respectively. Calculated margin losses were -2.3, -3.8, and -5.5 mm, for the 8:1, 4:1, and 2:1 cases, respectively. The maximum OAR doses were less than the maximum doses predicted on the bounded DVH curves for all scenarios. CONCLUSION With sufficient tracer uptake in the target, BgRT can deliver tracked dosimetry for targets with a large respiratory motion profile. Both the good BgRT candidate and borderline cases produced clinically acceptable delivered doses, even though the borderline case was flagged by the clinical system safety checks. As expected, the delivered BgRT dose distributions were suboptimal with reduced tumor over background PET contrast.
Collapse
|
16
|
Spatially Modulated Fiber Speckle for High-Sensitivity Refractive Index Sensing. SENSORS (BASEL, SWITZERLAND) 2023; 23:6814. [PMID: 37571597 PMCID: PMC10422477 DOI: 10.3390/s23156814] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 07/21/2023] [Accepted: 07/29/2023] [Indexed: 08/13/2023]
Abstract
A fiber speckle sensor (FSS) based on a tapered multimode fiber (TMMF) has been developed to measure liquid analyte refractive index (RI) in this work. By the lateral and axial offset of input light into TMMF, several high-order modes are excited in TMMF, and the speckle pattern is spatially modulated, which affects an asymmetrical speckle pattern with a random intensity distribution at the output of TMMF. When the TMMF is immersed in the liquid analyte with RI variation, it influences the guided modes, as well as the mode interference, in TMMF. A digital image correlations method with zero-mean normalized cross-correlation coefficient is explored to digitize the speckle image differences, analyzing the RI variation. It is found that the lateral- and axial-offsets-induced speckle sensor can enhance the RI sensitivity from 6.41 to 19.52 RIU-1 compared to the one without offset. The developed TMMF speckle sensor shows an RI resolution of 5.84 × 10-5 over a linear response range of 1.3164 to 1.3588 at 1550 nm. The experimental results indicate the FSS provides a simple, efficient, and economic approach to RI sensing, which exhibits an enormous potential in the image-based ocean-sensing application.
Collapse
|
17
|
[Long-term mortality risk of valvular heart disease adults over 35 years old in Chinese communities]. ZHONGHUA YI XUE ZA ZHI 2023; 103:1818-1823. [PMID: 37357186 DOI: 10.3760/cma.j.cn112137-20221118-02430] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/27/2023]
Abstract
Objective: To investigate the risk and influencing factors of long-term mortality of valvular heart disease (VHD) adults aged 35 years and over in Chinese communities. Methods: A cohort study was carried out. The data of the subjects who underwent echocardiography were collected from the Chinese Hypertension Survey between 2012 and 2015 and survival outcomes were followed up between 2018 and 2019. Kaplan-Meier survival curves were plotted and compared using log-rank test. Cox proportional hazards models were used to analyze the influence of VHD on mortality. Results: During an average follow-up time of (4.6±0.9) years, a total of 23 237 participants (10 881 males and 12 356 females) were pooled into the final analysis from 5 eastern, 5 central, and 4 western provinces, cities and autonomous regions in China, with a mean age of (56.9±13.2) years. Among the included participants, 1 004 had VHD (467 males and 537 females), with a mean age was of (68.1±12.6) years. In the Kaplan-Meier analysis, participants with VHD had a significantly increased risk of all-cause mortality (log-rank χ2=351.82, P<0.001) and cardiovascular mortality (log-rank χ2=284.14, P<0.001) compared with those without VHD. Multivariate Cox regression analysis showed that compared with those without VHD, the participants with rheumatic VHD had a 45% increased risk of all-cause mortality (HR=1.45, 95%CI: 1.12-1.89) and degenerative VHD increased the risk of cardiovascular mortality by 69% (HR=1.69, 95%CI: 1.19-2.38). The risk factors of cardiovascular mortality for VHD were age 55 years and over (55-<75 years: HR=4.93, 95%CI: 1.17-20.85;≥75 years: HR=11.92, 95%CI: 2.85-49.80) and diabetes mellitus (HR=1.71, 95%CI: 1.00-2.93). Conclusions: VHD is a risk factor of all-cause mortality and cardiovascular mortality among adults aged 35 years and over. Age 55 years and over and diabetes mellitus are adverse prognostic factors for patients with VHD.
Collapse
|
18
|
Fiber Laser-Based Lasso-Shaped Biosensor for High Precision Detection of Cancer Biomarker-CEACAM5 in Serum. BIOSENSORS 2023; 13:674. [PMID: 37504073 PMCID: PMC10377356 DOI: 10.3390/bios13070674] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 06/09/2023] [Accepted: 06/21/2023] [Indexed: 07/29/2023]
Abstract
Detection of trace tumor markers in blood/serum is essential for the early screening and prognosis of cancer diseases, which requires high sensitivity and specificity of the assays and biosensors. A variety of label-free optical fiber-based biosensors has been developed and yielded great opportunities for Point-of-Care Testing (POCT) of cancer biomarkers. The fiber biosensor, however, suffers from a compromise between the responsivity and stability of the sensing signal, which would deteriorate the sensing performance. In addition, the sophistication of sensor preparation hinders the reproduction and scale-up fabrication. To address these issues, in this study, a straightforward lasso-shaped fiber laser biosensor was proposed for the specific determination of carcinoembryonic antigen (CEA)-related cell adhesion molecules 5 (CEACAM5) protein in serum. Due to the ultra-narrow linewidth of the laser, a very small variation of lasing signal caused by biomolecular bonding can be clearly distinguished via high-resolution spectral analysis. The limit of detection (LOD) of the proposed biosensor could reach 9.6 ng/mL according to the buffer test. The sensing capability was further validated by a human serum-based cancer diagnosis trial, enabling great potential for clinical use. The high reproduction of fabrication allowed the mass production of the sensor and extended its utility to a broader biosensing field.
Collapse
|
19
|
A tera-electron volt afterglow from a narrow jet in an extremely bright gamma-ray burst. Science 2023:eadg9328. [PMID: 37289911 DOI: 10.1126/science.adg9328] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Accepted: 05/25/2023] [Indexed: 06/10/2023]
Abstract
Some gamma-ray bursts (GRBs) have a tera-electron volt (TeV) afterglow, but the early onset of this has not been observed. We report observations with the Large High Altitude Air Shower Observatory of the bright GRB 221009A, which serendipitously occurred within the instrument field of view. More than 64,000 photons >0.2 TeV were detected within the first 3000 seconds. The TeV flux began several minutes after the GRB trigger, then rose to a peak about 10 seconds later. This was followed by a decay phase, which became more rapid ~650 seconds after the peak. We interpret the emission using a model of a relativistic jet with half-opening angle ~0.8°. This is consistent with the core of a structured jet and could explain the high isotropic energy of this GRB.
Collapse
|
20
|
Caspase-3 in glioma indicates an unfavorable prognosis by involving surrounding angiogenesis and tumor cell repopulation. J Neurooncol 2023:10.1007/s11060-023-04339-x. [PMID: 37195411 DOI: 10.1007/s11060-023-04339-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Accepted: 05/06/2023] [Indexed: 05/18/2023]
Abstract
AIM Effective biomarkers for estimating glioma prognosis are deficient. Canonically, caspase-3 acts as an "apoptosis executioner". However, its prognostic role in glioma and mechanistic effects on prognosis remain unclear. METHODS With glioma tissue microarrays, the prognostic roles of cleaved caspase-3 and its association with angiogenesis were explored. Next, by analyzing the mRNA microarray data from the CGGA, the prognostic role of CASP3 expression and correlations between CASP3 and markers of glioma angiogenesis and proliferation were investigated. To biologically interpret the prognostic role of caspase-3 in glioma, the influence of caspase-3 on surrounding angiogenesis and glioma cell repopulation was investigated with an in vitro cell co-culture model, which comprises irradiated U87 cells and un-irradiated firefly luciferase (Fluc)-labeled HUVEC (HUVEC-Fluc) or U87 (U87-Fluc) cells. The over-expressed dominant-negative caspase-3 was used to suppress normal caspase-3 activity. RESULTS High levels of cleaved caspase-3 expression were associated with poor survival outcomes in glioma patients. Higher microvessel density was observed in patients with high levels of cleaved caspase-3 expression. By mining the microarray data in CGGA, it was revealed that higher CASP3 expression was found in glioma patients with lower Karnofsky Performance score, higher WHO grade, malignant histological subtype, wild-type IDH. Higher CASP3 expression indicated a worse survival rate in glioma patients. Patients with high CASP3 expression and negative IDH mutation showed the worst survival rate. Positive correlations were found between CASP3 and markers of tumor angiogenesis and proliferation. Subsequent data based on an in vitro cell co-culture model revealed that caspase-3 in irradiated glioma cells mediated pro-angiogenic and repopulation-promoting effects via regulating COX-2 signaling. With glioma tissue microarrays, high levels of COX-2 expression showed inferior survival outcomes in glioma patients. Glioma patients with high levels of cleaved caspase-3 and COX-2 expression showed the worst survival outcomes. CONCLUSION This study innovatively identified an unfavorable prognostic role of caspase-3 in glioma. The pro-angiogenic and repopulation-prompting effects of caspase-3/COX-2 signaling may explain its unfavorable prognostic role and offer novel insights into therapy sensitization and curative effect prediction of glioma.
Collapse
|
21
|
[Prevalence of albuminuria and its association with cardiovascular diseases in Chinese residents aged over 35 years]. ZHONGHUA NEI KE ZA ZHI 2023; 62:290-296. [PMID: 36822855 DOI: 10.3760/cma.j.cn112138-20220328-00214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 02/25/2023]
Abstract
Objective: To investigate the prevalence of albuminuria in Chinese residents aged >35 years and its potential association with cardiovascular disease (CVD). Methods: A total of 34 647 Chinese subjects aged ≥35 years were selected by stratified multi-stage random sampling from 2012 to 2015. Data were collected through questionnaires, physical examinations, and laboratory tests. Albuminuria was categorized into 3 types according to urinary albumin-to- creatinine ratio: normal (<30 mg/g), microalbuminuria (MAU, 30-300 mg/g), and macroalbuminuria (≥300 mg/g). Measurement data were expressed as x¯±s, and t-tests were used for comparisons between indicators. Qualitative data were expressed as rate or constituent ratio, and the χ2 test or Kruskal-Wallis test was used to examine differences. Logistic regression was used for multivariate analyses. SAS 9.4 software was used for statistical analyses, and P<0.05 was considered statistically significant. Results: The prevalence of abnormal albuminuria was 19.1%; the prevalence was 17.2% for MAU and lower in males (13.8%) than females (20.1%, P<0.01). The risk of CVD was higher among subjects with MAU (OR=1.23, 95%CI 1.12-1.35) and macroalbuminuria (OR=1.86, 95%CI 1.50-2.32). When MAU was complicated by hypertension and diabetes mellitus, the CVD risk was 1.76 times higher. Conclusions: The prevalence of MAU is high among Chinese subjects aged 35 years and over. Those with MAU have higher CVD risk, especially those with hypertension and diabetes mellitus.
Collapse
|
22
|
High-speed ADC based on photonic time-stretched technology with dispersion-tunable CFBG. OPTICS EXPRESS 2023; 31:8274-8285. [PMID: 36859943 DOI: 10.1364/oe.479846] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Accepted: 01/19/2023] [Indexed: 06/18/2023]
Abstract
We propose a photonic time-stretched analog-to-digital converter (PTS-ADC) based on dispersion-tunable chirped fiber Bragg grating (CFBG), by demonstrating a economical ADC system with seven different stretch factors. The stretch factors are tunable by changing the dispersion of CFBG, in order to obtain different sampling points. Accordingly, the total sampling rate of the system can be improved. Only a single channel is required to increase the sampling rate and achieve the effect of multi-channel sampling. Finally, seven groups of different stretch factors ranging from 1.882 to 2.206 are obtained, which are equivalent to seven groups of different sampling points. We successfully recover the input radio frequency (RF) signals with frequencies from 2 GHz to 10 GHz. In addition, the sampling points are increased by 14.4 times and the equivalent sampling rate is increased to 288 GSa/s. The proposed scheme is suitable for commercial microwave radar systems, which can obtain a much higher sampling rate at a low cost.
Collapse
|
23
|
Accelerating the phase demodulation process for heterodyne Φ-OTDR using spatial phase shifting. OPTICS LETTERS 2023; 48:1048-1051. [PMID: 36791007 DOI: 10.1364/ol.482219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Accepted: 01/15/2023] [Indexed: 06/18/2023]
Abstract
An effective orthogonal signal generation method for heterodyne-detection-based phase-sensitive optical time-domain reflectometer systems is proposed to accelerate the phase demodulation process. The demodulation principle is based on the spatial phase shifting technique. By exploiting the relative phase difference between adjacent spatial sampling channels, the orthogonal signal is easily obtained from basic algebra calculations. The simulation and experimental results showed that the proposed method achieved >100% computation speed improvement compared with the conventional methods, with a slight trade-off in phase demodulation performance. Therefore, the proposed method is potentially beneficial for the distributed acoustic sensing technology for reducing the computation complexity of phase demodulation procedures.
Collapse
|
24
|
[Current status of hypertension prevalence, treatment and control rate among young and middle-aged population in China]. ZHONGHUA XIN XUE GUAN BING ZA ZHI 2022; 50:1169-1176. [PMID: 36517437 DOI: 10.3760/cma.j.cn112148-20220916-00721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Objective: To estimate the prevalence, awareness, treatment and control rate of hypertension among young and middle-aged population in China. Methods: The analysis was based on the results of 2012-2015 China Hypertension Survey, which was a cross-sectional stratified multistage random sampling survey. A total of 229 593 subjects were included in the final analysis. The data including sex, age, living in urban and rural areas, prevalence of hypertension, history of stroke, family history of coronary heart disease and drinking, physical examination, heart rate were collected. Hypertension was defined as mean systolic blood pressure (SBP) ≥140 mmHg (1 mmHg=0.133 kPa), and (or) diastolic blood pressure (DBP) ≥90 mmHg, and (or) self-report a history of hypertension, and (or) use of antihypertensive medicine within 2 weeks before survey. Prehypertension was defined as SBP between 120-139 mmHg, and (or) DBP between 80-89 mmHg. Control of hypertension was considered for hypertensive individuals with SBP<140 mmHg and DBP<90 mmHg. The prevalence of prehypertension, hypertension, awareness, treatment, control rate were calculated, and the control rate among those with antihypertensive medication was also calculated. Results: The prevalence of prehypertension and hypertension was 43.8% (95%CI: 42.3%-45.4%), and 22.1% (95%CI: 20.8%-23.3%), respectively. The prevalence of prehypertension and hypertension was significantly higher among male than female across different age groups. The awareness, treatment, control rate of hypertension and control rate among treated hypertensive participants were 43.8%, 33.2%, 16.7%, and 40.2%, respectively. The prevalence was higher, and the control rate was lower among individuals with higher heart rate. Conclusion: The prevalence of prehypertension and hypertension among young and middle-aged population is high, the awareness, treatment and control rate need to be further improved in this population. The prevention and treatment of hypertension should be strengthened in the future to improve the control rate of hypertension in China.
Collapse
|
25
|
Constraints on Heavy Decaying Dark Matter from 570 Days of LHAASO Observations. PHYSICAL REVIEW LETTERS 2022; 129:261103. [PMID: 36608208 DOI: 10.1103/physrevlett.129.261103] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 08/19/2022] [Accepted: 10/27/2022] [Indexed: 06/17/2023]
Abstract
The kilometer square array (KM2A) of the large high altitude air shower observatory (LHAASO) aims at surveying the northern γ-ray sky at energies above 10 TeV with unprecedented sensitivity. γ-ray observations have long been one of the most powerful tools for dark matter searches, as, e.g., high-energy γ rays could be produced by the decays of heavy dark matter particles. In this Letter, we present the first dark matter analysis with LHAASO-KM2A, using the first 340 days of data from 1/2-KM2A and 230 days of data from 3/4-KM2A. Several regions of interest are used to search for a signal and account for the residual cosmic-ray background after γ/hadron separation. We find no excess of dark matter signals, and thus place some of the strongest γ-ray constraints on the lifetime of heavy dark matter particles with mass between 10^{5} and 10^{9} GeV. Our results with LHAASO are robust, and have important implications for dark matter interpretations of the diffuse astrophysical high-energy neutrino emission.
Collapse
|
26
|
In-Line Mach Zehnder Interferometer Based on Ytterbium Doped Fiber with Up-Taper Structure in Fiber Ring Laser and Its Application in Sensing. SENSORS (BASEL, SWITZERLAND) 2022; 22:9196. [PMID: 36501899 PMCID: PMC9740618 DOI: 10.3390/s22239196] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 11/16/2022] [Accepted: 11/24/2022] [Indexed: 06/17/2023]
Abstract
We report an ytterbium (Yb) doped fiber Mach Zehnder interferometer (MZI) based on the up-taper fiber structure in a fiber ring laser (FRL) cavity. Different from the traditional FRL sensing system, in which additional filters are required, the designed structure simultaneously acts as a filter, sensor and gain medium. Furthermore, thanks to the high thermal-optical coefficient of Yb doped fiber, the temperature sensitivity of 0.261 nm/°C can be achieved in the range of 10-50 °C. In addition, benefiting from the unique characteristics of the laser system itself, the designed structure has a narrower linewidth (-0.2 nm) and a higher signal-to-noise ratio (SNR) (-40 dB) than the sensor system based on a broadband light source (BBS). Meanwhile, the refractive index (RI) response and stability of the system are measured. The RI sensitivity is up to 151 nm/RIU, and the wavelength fluctuation range within two hours is less than 0.2 nm. Therefore, the designed structure is expected to play a significant role in human life safety monitoring, aircraft engine temperature monitoring, etc.
Collapse
|
27
|
Salinity and Temperature Dual-Parameter Sensor Based on Fiber Ring Laser with Tapered Side-Hole Fiber Embedded in Sagnac Interferometer. SENSORS (BASEL, SWITZERLAND) 2022; 22:8533. [PMID: 36366231 PMCID: PMC9657460 DOI: 10.3390/s22218533] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/08/2022] [Revised: 10/25/2022] [Accepted: 11/03/2022] [Indexed: 06/16/2023]
Abstract
This paper presented a new kind of salinity and temperature dual-parameter sensor based on a fiber ring laser (FRL) with tapered side-hole fiber (SHF) embedded in a Sagnac interferometer. The sensing structure is majorly composed of tapered SHF located in the middle of SHF inside the Sagnac interferometer loop structure. The influences of the SHF's diameters of different tapered in the Sagnac interferometer loop on the FRL sensing system are studied. The presence of air holes in the SHF makes the cladding mode easier to excite, and the interaction between the cladding mode with its surroundings is enhanced, thus having higher salinity sensitivity. Besides, the unique advantages of high resolution, narrower linewidth, and high signal-to-noise ratio (SNR) of fiber laser make the measurement results more accurate. In this experiment, the SHF with different taper diameters was made, and it was found that reducing the diameter of the taper waist diameter could further improve the salinity sensitivity. When the waist diameter was 9.70 μm, the maximum salinity sensitivity of 0.2867 nm/‱ was achieved. Temperature sensing experiments were also carried out. The maximum temperature sensitivity of the FRL sensing system was -0.3041 nm/°C at the temperature range from 20 to 30 °C. The sensor has the characteristics of easy manufacture, good selectivity, and high sensitivity, proving the feasibility of simultaneous measurement of seawater salinity and temperature.
Collapse
|
28
|
Robustness of Biology-Guided Radiotherapy Delivery to PET Biodistribution Changes within Target. Int J Radiat Oncol Biol Phys 2022. [DOI: 10.1016/j.ijrobp.2022.07.2180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
|
29
|
Adaptive Fiber-Ring Lasers Based on Isopropanol Filled Microfiber Coupler for High-Sensitivity Temperature Sensing. MICROMACHINES 2022; 13:1697. [PMID: 36296050 PMCID: PMC9610885 DOI: 10.3390/mi13101697] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/17/2022] [Revised: 10/04/2022] [Accepted: 10/07/2022] [Indexed: 06/16/2023]
Abstract
We demonstrated a new method for temperature measurement inside a fiber ring laser (FRL) cavity. Different from traditional FRL temperature sensing system which need additional filter working as a sensor, a micro-fiber coupler (MFC) was designed as a beam splitter, filter, and temperature sensor. In addition, isopropanol, a liquid with very high photothermal coefficient, is selectively filled in the MFC in order to improve the sensitivity of the system on temperature. In the dynamic range of 20-40 °C, we obtained a good temperature sensitivity of -1.29 nm/°C, with linear fitting up to 0.998. Benefiting from the advantages of laser sensing, the acquired laser has a 3 - dB bandwidth of less than 0.2 nm and a signal-to-noise ratio (SNR) of up to 40 dB. The proposed sensor has a low cost and high sensitivity, which is expected to be used in biomedical health detection, real-time monitoring of ocean temperature, and other application scenarios.
Collapse
|
30
|
Reconstruction of Cherenkov image by multiple telescopes of LHAASO-WFCTA. RADIATION DETECTION TECHNOLOGY AND METHODS 2022. [DOI: 10.1007/s41605-022-00342-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
31
|
1077P An updated network meta-analysis of EGFR-TKIs and combination therapy in the first-line treatment of the advanced EGFR mutation positive non-small cell lung cancer. Ann Oncol 2022. [DOI: 10.1016/j.annonc.2022.07.1203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
32
|
334P Adjuvant radiotherapy improves overall survival in patients with stage T4N0-2M0 sigmoid colon cancer. Ann Oncol 2022. [DOI: 10.1016/j.annonc.2022.07.472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
33
|
Data Reduction in Phase-Sensitive OTDR with Ultra-Low Sampling Resolution and Undersampling Techniques. SENSORS (BASEL, SWITZERLAND) 2022; 22:6386. [PMID: 36080845 PMCID: PMC9459960 DOI: 10.3390/s22176386] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/10/2022] [Revised: 08/20/2022] [Accepted: 08/22/2022] [Indexed: 06/15/2023]
Abstract
Data storage is a problem that cannot be ignored in the long-term monitoring of a phase-sensitive optical time-domain reflectometry (Φ-OTDR) system. In this paper, we proposed a data-reduction approach for heterodyne Φ-OTDR using an ultra-low sampling resolution and undersampling techniques. The operation principles were demonstrated and experiments with different sensing configurations were carried out to verify the proposed method. The results showed that the vibration signal could be accurately reconstructed from the undersampled 1-bit data. A space saving ratio of 98.75% was achieved by converting 128 MB of data (corresponding to 268.44 ms of sensing time) to 1.6 MB. The proposed method led to a potentially new data-reduction approach for heterodyne Φ-OTDR, which also provided economical guidance for the selection of the data-acquisition device.
Collapse
|
34
|
Search for continuous gravitational wave emission from the Milky Way center in O3 LIGO-Virgo data. Int J Clin Exp Med 2022. [DOI: 10.1103/physrevd.106.042003] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
35
|
Hybrid B-OTDR/Φ-OTDR for multi-parameter measurement from a single end of fiber. OPTICS EXPRESS 2022; 30:29117-29127. [PMID: 36299094 DOI: 10.1364/oe.463127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Accepted: 07/04/2022] [Indexed: 06/16/2023]
Abstract
The multi-parameter sensing is in great demand for comprehensive recognition in various application scenarios. We demonstrate a distributed optical fiber sensor (DOFS) for simultaneous vibration and temperature/strain sensing based on the integration of Brillouin optical time-domain reflectometry (BOTDR) and phase-sensitive optical time-domain reflectometry (Φ-OTDR). A double heterodyne detection configuration is set up to receive the Rayleigh scattering and Brillouin scattering simultaneously, which can enhance the signal-to-noise ratio (SNR) and reduce the polarization fading noise for the Brillouin signal at the same time. Most components in the setup are multiplexed for the Brillouin and Rayleigh signals. The overall cost is much lower than the summation of the BOTDR and the Φ-OTDR setup. In experiments, the setup is capable of measuring temperature change near the end of the 49.9 km long fiber with 0.381 MHz measurement uncertainty and restore different vibration patterns correctly by demodulating the phase variation of Rayleigh scattering signal, owning a 20 m spatial resolution. The sampling rate of the vibration measurement is 1.8 kHz, and the achieved dynamic strain resolution is 1.235 nɛ/√Hz with 100 Hz vibration.
Collapse
|
36
|
Ultra-low sampling resolution technique for heterodyne phase-OTDR based distributed acoustic sensing. OPTICS LETTERS 2022; 47:3379-3382. [PMID: 35838684 DOI: 10.1364/ol.456925] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Accepted: 06/12/2022] [Indexed: 06/15/2023]
Abstract
Phase-sensitive optical time-domain reflectometry (Φ-OTDR) based on heterodyne detection is widely used for its simple structure and high signal-to-noise ratio (SNR). However, the large amount of raw data of Φ-OTDR places a heavy burden on the storage device and also limits the transferability of the data. In this Letter, we propose an ultra-low sampling resolution technique to solve the data storage problem in heterodyne Φ-OTDR. Experimental results show that the optical phase variations induced by external vibrations can be successfully demodulated from the 1-bit-resolution raw data, and a vibration SNR of 58.03 dB is achieved. In addition, this work also reveals that a data acquisition device with extremely low sampling resolution is sufficient for heterodyne Φ-OTDR, signifying that the cost of the system can be further decreased.
Collapse
|
37
|
[Investigate developmental coordination disorder of kindergarten children in Zhejiang Province]. ZHONGHUA YU FANG YI XUE ZA ZHI [CHINESE JOURNAL OF PREVENTIVE MEDICINE] 2022; 56:838-842. [PMID: 35785866 DOI: 10.3760/cma.j.cn112150-20210719-00691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
In order to investigate developmental coordination disorder (DCD) of kindergarten children in Zhejiang province, 200 ordinary kindergartens were randomly selected by stratified random sampling in 11 prefecture-level cities of Zhejiang Province, and 38 900 children from 1 000 classes in each grade were then randomly selected into the study from June 2019 to December 2019. The Little DCD Questionnaire and a self-designed questionnaire were used to screen the DCD of those children. There were 36 807 valid questionnaires, and 6.50% (2 391/36 807) of them were positive results. The results showed that boy, age ≤5 years, overweight or obesity, left handedness, comorbidity with motor or developmental disorders and premature infants were risk factors of DCD in children. As for parents and families, maternal gestational age<20 years, maternal overweight or obesity before pregnancy, low-middle level education of parents, direct family and low income of family were also associated with DCD in children. Therefore, it is necessary to conduct early prevention and intervention strategies targeting on identified risk factors among relevant population.
Collapse
|
38
|
All-sky, all-frequency directional search for persistent gravitational waves from Advanced LIGO’s and Advanced Virgo’s first three observing runs. Int J Clin Exp Med 2022. [DOI: 10.1103/physrevd.105.122001] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
39
|
Effects of aerobic exercise on inflammatory factors in healthy adults: a meta-analysis. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES 2022; 26:4163-4175. [PMID: 35776016 DOI: 10.26355/eurrev_202206_29053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
OBJECTIVE With this meta-analysis we aimed at systematically evaluating the intervention effects of aerobic exercise on inflammatory factors in healthy adults and identifying an optimal aerobic exercise program with anti-inflammatory effects. MATERIALS AND METHODS Four databases, including PubMed, Web of Science, Cochrane Library and SPORTDiscus, were searched from inception until April 30, 2021. Stata version 11.0 was used for data analysis. RESULTS A total of 15 studies with 1160 participants were included. The pooled estimates showed that aerobic exercise could significantly reduce TNFα levels (SMD=-0.30, 95% CI: -0.58 - -0.03, p=0.032), while the levels of IL-6 (SMD=-0.14, 95% CI: -0.32-0.03, p=0.109) and CRP (SMD=-0.09, 95% CI: -0.34-0.16, p=0.484) were not significantly affected. CONCLUSIONS Aerobic exercise exerts a positive effect by preventing inflammation-related diseases.
Collapse
|
40
|
Process Development and Manufacturing: CAR-T CELL EXPANSION PLATFORMS YIELD DISTINCT PHENOTYPIC AND TRANSCRIPTIONAL PROFILES. Cytotherapy 2022. [DOI: 10.1016/s1465-3249(22)00111-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
41
|
Quantitative demodulation of distributed low-frequency vibration based on phase-shifted dual-pulse phase-sensitive OTDR with direct detection. OPTICS EXPRESS 2022; 30:10096-10109. [PMID: 35299420 DOI: 10.1364/oe.453060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Accepted: 03/04/2022] [Indexed: 06/14/2023]
Abstract
Phase-sensitive optical time-domain reflectometry (Φ-OTDR) has been proposed for distributed vibration sensing purpose over recent years. Emerging applications, including seismic and hydroacoustic wave detection, demand accurate low-frequency vibration reconstruction capability. We propose to use the direct-detection Φ-OTDR configuration to achieve quantitative demodulation of external low-frequency vibrations by phase-shifted dual-pulse probes. Simultaneous pulsing and phase shifting modulation is realized with a single acousto-optic modulator to generate such probes, relaxing the need for an additional optical phase modulator. In the experiments, vibrations with frequency as low as 0.5 Hz are successfully reconstructed with 10 m spatial resolution and 35 dB signal-to-noise ratio. Excellent linearity and repeatability are demonstrated between the optical phase demodulation results and the applied vibration amplitudes. The proposed method is capable of quantitative demodulation of low-frequency vibrations with a cost-effective system configuration and high computation efficiency, showing potential for commercial applications of distributed seismic or hydroacoustic wave acquisition.
Collapse
|
42
|
Real-Time Multi-Class Disturbance Detection for Φ-OTDR Based on YOLO Algorithm. SENSORS 2022; 22:s22051994. [PMID: 35271143 PMCID: PMC8915082 DOI: 10.3390/s22051994] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Revised: 02/26/2022] [Accepted: 03/02/2022] [Indexed: 02/04/2023]
Abstract
This paper proposes a real-time multi-class disturbance detection algorithm based on YOLO for distributed fiber vibration sensing. The algorithm achieves real-time detection of event location and classification on external intrusions sensed by distributed optical fiber sensing system (DOFS) based on phase-sensitive optical time-domain reflectometry (Φ-OTDR). We conducted data collection under perimeter security scenarios and acquired five types of events with a total of 5787 samples. The data is used as a spatial–temporal sensing image in the training of our proposed YOLO-based model (You Only Look Once-based method). Our scheme uses the Darknet53 network to simplify the traditional two-step object detection into a one-step process, using one network structure for both event localization and classification, thus improving the detection speed to achieve real-time operation. Compared with the traditional Fast-RCNN (Fast Region-CNN) and Faster-RCNN (Faster Region-CNN) algorithms, our scheme can achieve 22.83 frames per second (FPS) while maintaining high accuracy (96.14%), which is 44.90 times faster than Fast-RCNN and 3.79 times faster than Faster-RCNN. It achieves real-time operation for locating and classifying intrusion events with continuously recorded sensing data. Experimental results have demonstrated that this scheme provides a solution to real-time, multi-class external intrusion events detection and classification for the Φ-OTDR-based DOFS in practical applications.
Collapse
|
43
|
Optical curvature sensor with high resolution based on in-line fiber Mach-Zehnder interferometer and microwave photonic filter. OPTICS EXPRESS 2022; 30:5402-5413. [PMID: 35209503 DOI: 10.1364/oe.445982] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Accepted: 01/19/2022] [Indexed: 06/14/2023]
Abstract
Curvature measurement plays an important role in structural health monitoring, robot-pose measuring, etc. High-resolution curvature measurement is highly demanded. In this paper, an optical curvature sensor with high resolution based on in-fiber Mach-Zehnder interferometer (MZI) and microwave photonic filter (MPF) is proposed and experimentally demonstrated. The in-fiber MZI is constructed with a ring-core fiber (RCF) which is fusion spliced between two coreless fibers (CLFs). The structure of CLF-RCF-CLF is then sandwiched between two segments of single-mode fiber (SMF), making the whole interferometer structure of SMF-CLF-RCF-CLF-SMF. The operating principle is that different curvatures will cause the variations of the interference spectrum of MZI due to elastic-optic effect, and then the variations are converted into the frequency-shift of the MPF. The factors affecting the visibility of the interference spectrum are researched. A preliminary exploration of the multiplexing demodulation for the in-fiber-MZIs is also investigated and discussed, which is for the first time to the best of our knowledge, holding great potential to pave the way for constructing the sensing network composed of interferometric sensors. The curvature measurement sensitivity is -147.634 MHz/m-1, and the resolution is 6.774 × 10-6 m-1 which is the highest value up to now.
Collapse
|
44
|
Exploring Lorentz Invariance Violation from Ultrahigh-Energy γ Rays Observed by LHAASO. PHYSICAL REVIEW LETTERS 2022; 128:051102. [PMID: 35179919 DOI: 10.1103/physrevlett.128.051102] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Revised: 12/06/2021] [Accepted: 12/24/2021] [Indexed: 06/14/2023]
Abstract
Recently, the LHAASO Collaboration published the detection of 12 ultrahigh-energy γ-ray sources above 100 TeV, with the highest energy photon reaching 1.4 PeV. The first detection of PeV γ rays from astrophysical sources may provide a very sensitive probe of the effect of the Lorentz invariance violation (LIV), which results in decay of high-energy γ rays in the superluminal scenario and hence a sharp cutoff of the energy spectrum. Two highest energy sources are studied in this work. No signature of the existence of the LIV is found in their energy spectra, and the lower limits on the LIV energy scale are derived. Our results show that the first-order LIV energy scale should be higher than about 10^{5} times the Planck scale M_{Pl} and that the second-order LIV scale is >10^{-3}M_{Pl}. Both limits improve by at least one order of magnitude the previous results.
Collapse
|
45
|
The Effect of Education Intervention on Osteoporotic Fracture and Bone Mineral Density in Elderly Women With Osteoporosis: A Randomized Controlled Trial. Altern Ther Health Med 2022; 28:89-95. [PMID: 34936992] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
OBJECTIVE This study aimed to assess whether a 5-year follow-up education intervention changed the risk for fragility fractures and increased bone mineral density (BMD) in elderly women with osteoporosis. METHODS This randomized controlled trial included 104 women who were hospitalized or visited a specialist for osteoporosis care at Sichuan Translational Medicine Research Hospital in China from October 2013 to June 2014. The patients were randomly assigned to either an education intervention group (n = 52) or a control group (n = 52). The intervention was conducted by an endocrinologist who provided the intervention group with personized recommendations. All participants were followed for 5 years. RESULTS Compared with the control group, the patients in the intervention group had a lower risk for fragility fracture, lower pain score, higher BMD at the greater trochanter of the femur, total hip and the first lumbar vertebra, together with higher compliance with anti-osteoporosis drug regimens and higher intake of vitamin D supplements (all P <.05). After adjustment for history of fracture, calcium consumption, age and body mass index (BMI), the association of change in BMD and pain score and the medication possession ratio (MPR) of anti-osteoporosis drugs were both significantly different (P < .05, P < .001, respectively). In subgroup analysis by past fractures, patients who experienced post-fractures were more likely to experience refracture (P < .05). CONCLUSIONS The personalized education intervention by endocrinologists can significantly increase the BMD of the greater trochanter of the femur and reduce pain scores in elderly women with osteoporosis, suggesting that this education intervention may serve as an important addition to standard anti-osteoporosis treatment.
Collapse
|
46
|
Physical Confirmation of Biology-Guided Radiotherapy Directed at Static Targets With Varying Shapes and Background Contrast Environments. Int J Radiat Oncol Biol Phys 2021. [DOI: 10.1016/j.ijrobp.2021.07.1406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
47
|
[Development of a fluorescent recombinase-aided isothermal amplification-based nucleic acid assay for detection of Leishmania]. ZHONGGUO XUE XI CHONG BING FANG ZHI ZA ZHI = CHINESE JOURNAL OF SCHISTOSOMIASIS CONTROL 2021; 33:452-456. [PMID: 34791841 DOI: 10.16250/j.32.1374.2021187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
OBJECTIVE To develop a fluorescent recombinase-aided isothermal amplification (RAA)-based nucleic acid assay for detection of Leshimania. METHODS Specific primers and probes were designed targeting Leishmania internal transcribed spacer 1 (ITS1) gene for RAA assay, and a fluorescent RAA assay was developed for detection of Leishmania following screening of primer pairs and optimization of primer and probe concentrations. The sensitivity of RAA assay for detection of Leishmania was evaluated using recombinant plasmid containing Leishmania ITS1 gene sequences at different copies and Leshimania genomic DNA at different concentrations as templates, and the specificity of RAA assay for detection of Leishmania was evaluated using the genomic DNA of transfusion-transmitted parasites, including Babesia microti, Toxoplasma gondii, Plamodium vivax, P. ovale, P. falciparum, P. malariae, L. donovani and L. infantum. RESULTS After the optimal primer pair was screened from 9 pairs of primer combinations, the final primer and probe concentrations were optimized as 0.3 μmol/L and 0.08 μmol/L, respectively. Nucleic acid detection of Leishmania was completed by the fluorescent RAA assay at an isothermal temperature of 39 °C within 20 min. Remarkable florescent signals were seen within 5 min following RAA detection of genomic DNA of L. donovani and L. infantum, and no cross-reactions were observed with B. microti, T. gondii, P. vivax, P. ovale, P. falciparum or P. malariae. The lowest limitation of detection of the fluorescent RAA assay was 10 copies/μL recombinant plasmid containing Leishmania ITS1 gene sequences and 1 fg/μL Leishmania genomic DNA. CONCLUSIONS A rapid, simple, sensitive and specific fluorescent RAA assay is successfully developed for detection of L. donovani and L. infantum, which is effective for field screening of leishmaniasis.
Collapse
|
48
|
Temperature Tolerance Electric Cell-Substrate Impedance Sensing for Joint Assessment of Cell Viability and Vitality. ACS Sens 2021; 6:3640-3649. [PMID: 34449212 DOI: 10.1021/acssensors.1c01211] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Evaluation of the cell health status is critical for drug screening and cell physiological activity investigations. The existing cell health assessment methods are solely devoted to the study of cell vitality or viability, leading to an incomplete evaluation. Herein, we report a convenient and robust method for the joint assessment of cell viability and vitality based on electric cell-substrate impedance sensing (ECIS) supplied with an environmental temperature control. The static value of electric cell-substrate impedance reflects the survival rate of cells, while the temperature tolerance of cells demonstrates the cell vitality. It was found that the cell vitality evaluated by the temperature tolerance of cells was independent of the initial cell numbers, rendering the proposed method easy to utilize in various applications. We compared the temperature tolerance ECIS method with the traditional trypan blue staining method, the methyl thiazolyl tetrazolium assay, and the direct impedance sensing method for joint evaluation of cell viability and vitality in drug screening. The temperature tolerance ECIS method showed comparable results but with a simpler protocol, faster results, and less dependence on the sample conditions. By providing both information on cell viability and cell vitality, the proposed temperature tolerance ECIS method would pave the way in building a simple and robust sensing system for cell health evaluation.
Collapse
|
49
|
A Multimodal Hydrogel Soft-Robotic Sensor for Multi-Functional Perception. Front Robot AI 2021; 8:692754. [PMID: 34513937 PMCID: PMC8427136 DOI: 10.3389/frobt.2021.692754] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Accepted: 07/30/2021] [Indexed: 12/22/2022] Open
Abstract
Soft robots, with their unique and outstanding capabilities of environmental conformation, natural sealing against elements, as well as being insensitive to magnetic/electrical effects, are ideal candidates for extreme environment applications. However, sensing for soft robots in such harsh conditions would still be challenging, especially under large temperature change and complex, large deformations. Existing soft sensing approaches using liquid-metal medium compromise between large deformation and environmental robustness, limiting their real-world applicability. In this work, we propose a multimodal solid-state soft sensor using hydrogel and silicone. By exploiting the conductance and transparency of hydrogel, we could deploy both optical and resistive sensing in one sensing component. This novel combination enables us to benefit from the in-situ measurement discrepancies between the optical and electrical signal, to extract multifunctional measurements. Following this approach, prototype solid-state soft sensors were designed and fabricated, a dedicated neural network was built to extract the sensory information. Stretching and twisting were measured using the same sensor even at large deformations. In addition, exploiting the distinctive responses against temperature change, we could estimate environmental temperatures simultaneously. Results are promising for the proposed solid-state multimodal approach of soft sensors for multifunctional perception under extreme conditions.
Collapse
|
50
|
A dynamic range extension system for LHAASO WCDA-1. RADIATION DETECTION TECHNOLOGY AND METHODS 2021. [DOI: 10.1007/s41605-021-00275-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|