1
|
Ferguson D, Harris T, Shi M, Jacobson M, Myronakis M, Lehmann M, Huber P, Morf D, Fueglistaller R, Baturin P, Valencia Lozano I, Williams C, Berbeco R. Automated MV markerless tumor tracking for VMAT. Phys Med Biol 2020; 65:125011. [PMID: 32330918 DOI: 10.1088/1361-6560/ab8cd3] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Tumor tracking during radiotherapy treatment can improve dose accuracy, conformity and sparing of healthy tissue. Many methods have been introduced to tackle this challenge utilizing multiple imaging modalities, including a template matching based approach using the megavoltage (MV) on-board portal imager demonstrated on 3D conformal treatments. However, the complexity of treatments is evolving with the introduction of VMAT and IMRT, and successful motion management is becoming more important due to a trend towards hypofractionation. We have developed a markerless lung tumor tracking algorithm, utilizing the electronic portal imager (EPID) of the treatment machine. The algorithm has been specifically adapted to track during complex treatment deliveries with gantry and MLC motion. The core of the algorithm is an adaptive template matching method that relies on template stability metrics and local relative orientations to perform multiple feature tracking simultaneously. Only a single image is required to initialize the algorithm and features are automatically added, modified or removed in response to the input images. This algorithm was evaluated against images collected during VMAT arcs of a dynamic thorax phantom. Dynamic phantom images were collected during radiation delivery for multiple lung SBRT breathing traces and an example patient data set. The tracking error was 1.34 mm for the phantom data and 0.68 mm for the patient data. A multi-region, markerless tracking algorithm has been developed, capable of tracking multiple features simultaneously without requiring any other a priori information. This novel approach delivers robust target localization during complex treatment delivery. The reported tracking error is similar to previous reports for 3D conformal treatments.
Collapse
|
Research Support, N.I.H., Extramural |
5 |
7 |
2
|
Harris TC, Seco J, Ferguson D, Lehmann M, Huber P, Shi M, Jacobson M, Valencia Lozano I, Myronakis M, Baturin P, Fueglistaller R, Morf D, Berbeco R. Clinical translation of a new flat-panel detector for beam's-eye-view imaging. Phys Med Biol 2020; 65:225004. [PMID: 33284786 PMCID: PMC9142212 DOI: 10.1088/1361-6560/abb571] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Electronic portal imaging devices (EPIDs) lend themselves to beams-eye view clinical applications, such as tumor tracking, but are limited by low contrast and detective quantum efficiency (DQE). We characterize a novel EPID prototype consisting of multiple layers and investigate its suitability for use under clinical conditions. A prototype multi-layer imager (MLI) was constructed utilizing four conventional EPID layers, each consisting of a copper plate, a Gd2O2S:Tb phosphor scintillator, and an amorphous silicon flat panel array detector. We measured the detector's response to a 6 MV photon beam with regards to modulation transfer function, noise power spectrum, DQE, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and the linearity of the detector's response to dose. Additionally, we compared MLI performance to the single top layer of the MLI and the standard Varian AS-1200 detector. Pre-clinical imaging was done on an anthropomorphic phantom, and the detector's CNR, SNR and spatial resolution were assessed in a clinical environment. Images obtained from spine and liver patient treatment deliveries were analyzed to verify CNR and SNR improvements. The MLI has a DQE(0) of 9.7%, about 5.7 times the reference AS-1200 detector. Improved noise performance largely drives the increase. CNR and SNR of clinical images improved three-fold compared to reference. A novel MLI was characterized and prepared for clinical translation. The MLI substantially improved DQE and CNR performance while maintaining the same resolution. Pre-clinical tests on an anthropomorphic phantom demonstrated improved performance as predicted theoretically. Preliminary patient data were analyzed, confirming improved CNR and SNR. Clinical applications are anticipated to include more accurate soft tissue tracking.
Collapse
|
Research Support, N.I.H., Extramural |
5 |
5 |
3
|
Harris TC, Jacobson M, Myronakis M, Lehmann M, Huber P, Morf D, Ozoemelam I, Hu YH, Ferguson D, Fueglistaller R, Corral Arroyo P, Berbeco RI. Impact of a novel multilayer imager on metal artifacts in MV-CBCT. Phys Med Biol 2023; 68:10.1088/1361-6560/ace09a. [PMID: 37343590 PMCID: PMC10382207 DOI: 10.1088/1361-6560/ace09a] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Accepted: 06/21/2023] [Indexed: 06/23/2023]
Abstract
Objective. Megavoltage cone-beam computed tomography (MV-CBCT) imaging offers several advantages including reduced metal artifacts and accurate electron density mapping for adaptive or emergent situations. However, MV-CBCT imaging is limited by the poor efficiency of current detectors. Here we examine a new MV imager and compare CBCT reconstructions under clinically relevant scenarios.Approach. A multilayer imager (MLI), consisting of four vertically stacked standard flat-panel imagers, was mounted to a clinical linear accelerator. A custom anthropomorphic pelvis phantom with replaceable femoral heads was imaged using MV-CBCT and kilovoltage CBCT (kV-CBCT). Bone, aluminum, and titanium were used as femoral head inserts. 8 MU 2.5 MV scans were acquired for all four layers and (as reference) the top layer. Prostate and bladder were contoured on a reference CT and transferred to the other scans after rigid registration, from which the structural similarity index measure (SSIM) was calculated. Prostate and bladder were also contoured on CBCT scans without guidance, and Dice coefficients were compared to CT contours.Main results. kV-CBCT demonstrated the highest SSIMs with bone inserts (prostate: 0.86, bladder: 0.94) and lowest with titanium inserts (0.32, 0.37). Four-layer MV-CBCT SSIMs were preserved with bone (0.75, 0.80) as compared to titanium (0.67, 0.74), outperforming kV-CBCT when metal is present. One-layer MV-CBCT consistently underperformed four-layer results across all phantom configurations. Unilateral titanium inserts and bilateral aluminum insert results fell between the bone and bilateral titanium results. Dice coefficients trended similarly, with four-layer MV-CBCT reducing metal artifact impact relative to KV-CBCT to provide better soft-tissue identification.Significance. MV-CBCT with a four-layer MLI showed improvement over single-layer MV scans, approaching kV-CBCT quality for soft-tissue contrast. In the presence of artifact-producing metal implants, four-layer MV-CBCT scans outperformed kV-CBCT by eliminating artifacts and single-layer MV-CBCT by reducing noise. MV-CBCT with a novel multi-layer imager may be a valuable alternative to kV-CBCT, particularly in the presence of metal.
Collapse
|
Research Support, N.I.H., Extramural |
2 |
3 |
4
|
Rottmann J, Myronakis M, Hu Y, Shedlock D, Wang A, Humber D, Morf D, Fueglistaller R, Star-Lack J, Berbeco R. WE-DE-BRA-04: A Cost-Effective Pixelated EPID Scintillator for Enhanced Contrast and DQE. Med Phys 2016. [DOI: 10.1118/1.4957833] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
|
9 |
2 |
5
|
Myronakis M, Cai W, Dhou S, Cifter F, Hurwitz M, Lewis J. SU-E-P-59: A Graphical Interface for XCAT Phantom Configuration, Generation and Processing. Med Phys 2015. [DOI: 10.1118/1.4923993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
|
10 |
|
6
|
Myronakis M, Rottmann J, Hu Y, Wang A, Shedlock D, Morf D, Star-Lack J, Berbeco R. Megavoltage Spectral Imaging Using a Layered Imager. Int J Radiat Oncol Biol Phys 2016. [DOI: 10.1016/j.ijrobp.2016.06.2272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
|
9 |
|
7
|
Dhou S, Cai W, Hurwitz M, Williams C, Rottmann J, Mishra P, Myronakis M, Cifter F, Berbeco R, Ionascu D, Lewis J. WE-G-207-06: 3D Fluoroscopic Image Generation From Patient-Specific 4DCBCT-Based Motion Models Derived From Physical Phantom and Clinical Patient Images. Med Phys 2015. [DOI: 10.1118/1.4926099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
|
10 |
|
8
|
Myronakis M, Stratakis J, Perisinakis K, Damilakis J. Machine learning estimation of personalized, organ-dose absorption from CT examinations. Phys Med 2021. [DOI: 10.1016/s1120-1797(22)00099-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
|
4 |
|
9
|
Myronakis M, Rottmann J, Hu Y, Wang A, Shedlock D, Morf D, Star-Lack J, Berbeco R. WE-DE-BRA-07: Megavoltage Spectral Imaging with a Layered Detector. Med Phys 2016. [DOI: 10.1118/1.4957836] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
|
9 |
|
10
|
Cai W, Hurwitz M, Williams C, Dhou S, Berbeco R, Seco J, Cifter F, Myronakis M, Mishra P, Lewis J. WE-D-303-03: 3D Delivered Dose Assessment Using a 4DCT-Based Motion Model. Med Phys 2015. [DOI: 10.1118/1.4925938] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
|
10 |
|
11
|
Myronakis M, Rottmann J, Hu Y, Wang A, Shedlock D, Morf D, Star-Lack J, Berbeco R. WE-DE-BRA-05: Monte Carlo Simulation of a Novel Multi-Layer MV Imager. Med Phys 2016. [DOI: 10.1118/1.4957834] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
|
9 |
|
12
|
Harris T, Seco J, Ferguson D, Jacobson M, Myronakis M, Lozano I, Lehmann M, Huber P, Fueglistaller R, Morf D, Mamon H, Mancias J, Martin N, Berbeco R. Beam's-Eye-View Imaging of Liver SBRT With a Novel Multi-Layer Imager. Int J Radiat Oncol Biol Phys 2021. [DOI: 10.1016/j.ijrobp.2021.07.127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
|
4 |
|
13
|
Cai W, Hurwitz M, Williams C, Dhou S, Berbeco R, Seco J, Cifter F, Myronakis M, Lewis J. WE-D-303-04: 4DCBCT-Based Dose Assessment for SBRT Lung Cancer Treatment. Med Phys 2015. [DOI: 10.1118/1.4925939] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
|
10 |
|
14
|
Harris TC, Seco J, Ferguson D, Jacobson M, Myronakis M, Lozano IV, Lehmann M, Huber P, Fueglistaller R, Morf D, Mamon HJ, Mancias JD, Martin NE, Berbeco RI. Improvements in beam's eye view fiducial tracking using a novel multilayer imager. Phys Med Biol 2021; 66:10.1088/1361-6560/ac1246. [PMID: 34233309 PMCID: PMC11102774 DOI: 10.1088/1361-6560/ac1246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Accepted: 07/07/2021] [Indexed: 11/12/2022]
Abstract
Purpose.Electronic portal image devices (EPIDs) have been investigated previously for beams-eye view (BEV) applications such as tumor tracking but are limited by low contrast-to-noise ratio and detective quantum efficiency. A novel multilayer imager (MLI), consisting of four stacked flat-panels was used to measure improvements in fiducial tracking during liver stereotactic body radiation therapy (SBRT) procedures compared to a single layer EPID.Methods.The prototype MLI was installed on a clinical TrueBeam linac in place of the conventional DMI single-layer EPID. The panel was extended during volumetric modulated arc therapy SBRT treatments in order to passively acquire data during therapy. Images were acquired for six patients receiving SBRT to liver metastases over two fractions each, one with the MLI using all 4 layers and one with the MLI using the top layer only, representing a standard EPID. The acquired frames were processed by a previously published tracking algorithm modified to identify implanted radiopaque fiducials. Truth data was determined using respiratory traces combined with partial manual tracking. Results for 4- and 1-layer mode were compared against truth data for tracking accuracy and efficiency. Tracking and noise improvements as a function of gantry angle were determined.Results. Tracking efficiency with 4-layers improved to 82.8% versus 58.4% for the 1-layer mode, a relative improvement of 41.7%. Fiducial tracking with 1-layer returned a root mean square error (RMSE) of 2.1 mm compared to 4-layer RMSE of 1.5 mm, a statistically significant (p < 0.001) improvement of 0.6 mm. The reduction in noise correlated with an increase in successfully tracked frames (r = 0.913) and with increased tracking accuracy (0.927).Conclusion. Increases in MV photon detection efficiency by utilization of a MLI results in improved fiducial tracking for liver SBRT treatments. Future clinical applications utilizing BEV imaging may be enhanced by including similar noise reduction strategies.
Collapse
|
Research Support, N.I.H., Extramural |
4 |
|
15
|
Hu Y, Fueglistaller R, Rottmann J, Myronakis M, Wang A, Shedlock D, Morf D, Star-Lack J, Berbeco R. SU-F-J-41: Experimental Validation of a Cascaded Linear System Model for MVCBCT with a Multi-Layer EPID. Med Phys 2016. [DOI: 10.1118/1.4955949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
|
9 |
|
16
|
Dhou S, Cifter F, Myronakis M, Berbeco R, Lewis J, Cai W. SU-E-I-03: Lateral Truncation Artifact Correction for 4DCBCT-Based Motion Modeling and Dose Assessment. Med Phys 2015. [DOI: 10.1118/1.4924000] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
|
10 |
|
17
|
Stratakis J, Myronakis M, Perisinakis K, Damilakis J. Evaluation of size-specific normalized doses for partially irradiated liver tissue in thorax MDCT examinations using modern MC techniques. Phys Med 2021. [DOI: 10.1016/s1120-1797(22)00489-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
|
4 |
|
18
|
Dhou S, Cai W, Hurwitz M, Williams C, Cifter F, Myronakis M, Ionascu D, Lewis J. SU-E-J-151: Day-To-Day Variations in Fraction-Specific Motion Modeling Using Patient 4DCBCT Images. Med Phys 2015. [DOI: 10.1118/1.4924236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
|
10 |
|
19
|
Sotiropoulou V, Myronakis M, Stratakis J, Damilakis J. INVESTIGATION OF MONTE CARLO PARAMETERS ON ORGAN DOSE ESTIMATION FOR PATIENTS UNDERGOING COMPUTED TOMOGRAPHY (CT) EXAMINATIONS. Phys Med 2022. [DOI: 10.1016/s1120-1797(22)03126-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
|
|
3 |
|
20
|
Myronakis M, Stratakis J, Mazonakis M, Lyraraki E, Damilakis J. TREATMENT PLANNING FOR PANCREATIC CANCER USING MODIFIED COMPUTATIONAL ANTHROPOMORPHIC PHANTOMS: DOSE DEPENDENCE ON HU VARIATION. Phys Med 2022. [DOI: 10.1016/s1120-1797(22)03081-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
|
|
3 |
|
21
|
Myronakis M, Cai W, Dhou S, Cifter F, Lewis J. SU-E-J-186: Using 4DCT-Based Motion Modeling to Predict Motion and Duty Cycle On Successive Days of Gated Radiotherapy. Med Phys 2015. [DOI: 10.1118/1.4924272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
|
10 |
|
22
|
Hu Y, Rottmann J, Myronakis M, Berbeco R. SU-G-BRA-06: Quantification of Tracking Performance of a Multi-Layer Electronic Portal Imaging Device. Med Phys 2016. [DOI: 10.1118/1.4956930] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
|
9 |
|
23
|
Hu Y, Rottmann J, Myronakis M, Berbeco R. Using Fractal Dimension Analysis to Distinguish Lung Tumors in MV Imaging. Int J Radiat Oncol Biol Phys 2016. [DOI: 10.1016/j.ijrobp.2016.06.2243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
|
9 |
|