1
|
Kukde R, Panda G, Manikandan MS. Bio‐inspired evolutionary computing approach for distributed active noise control problem. Cognitive Computation and Systems 2020. [DOI: 10.1049/ccs.2019.0030] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Affiliation(s)
- Ruchi Kukde
- School of Electrical SciencesIndian Institute of Technology BhubaneswarArgulOdishaIndia
| | - Ganapati Panda
- C. V. Raman College of EngineeringBhubaneswarOdishaIndia
| | | |
Collapse
|
2
|
Vadrevu S, Manikandan MS. Use of zero-frequency resonator for automatically detecting systolic peaks of photoplethysmogram signal. Healthc Technol Lett 2019; 6:53-58. [PMID: 31341628 PMCID: PMC6595535 DOI: 10.1049/htl.2018.5026] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2018] [Revised: 02/16/2019] [Accepted: 02/26/2019] [Indexed: 11/20/2022] Open
Abstract
This work investigates the application of zero-frequency resonator (ZFR) for detecting systolic peaks of photoplethysmogram (PPG) signals. Based on the authors' studies, they propose an automated noise-robust method, which consists of the central difference operation, the ZFR, the mean subtraction and averaging, the peak determination, and the peak rejection/acceptance rule. The method is evaluated using different kinds of PPG signals taken from the standard MIT-BIH polysomnographic database and Complex Systems Laboratory database and the recorded PPG signals at their Biomedical System Lab. The method achieves an average sensitivity (Se) of 99.95%, positive predictivity (Pp) of 99.89%, and overall accuracy (OA) of 99.84% on a total number of 116,673 true peaks. Evaluation results further demonstrate the robustness of the ZFR-based method for noisy PPG signals with a signal-to-noise ratio (SNR) ranging from 30 to 5 dB. The method achieves an average Se = 99.76%, Pp = 99.84%, and OA = 99.60% for noisy PPG signals with a SNR of 5 dB. Various results show that the method yields better detection rates for both noise-free and noisy PPG signals. The method is simple and reliable as compared with the complexity of signal processing techniques and detection performance of the existing detection methods.
Collapse
Affiliation(s)
- Simhadri Vadrevu
- School of Electrical Sciences, Indian Institute of Technology Bhubaneswar, Kurdha, Odisha-752050, India
| | - M Sabarimalai Manikandan
- School of Electrical Sciences, Indian Institute of Technology Bhubaneswar, Kurdha, Odisha-752050, India
| |
Collapse
|
3
|
Satija U, Ramkumar B, Manikandan MS. Automated ECG Noise Detection and Classification System for Unsupervised Healthcare Monitoring. IEEE J Biomed Health Inform 2018; 22:722-732. [DOI: 10.1109/jbhi.2017.2686436] [Citation(s) in RCA: 82] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
4
|
Deshpande PS, Manikandan MS. Effective Glottal Instant Detection and Electroglottographic Parameter Extraction for Automated Voice Pathology Assessment. IEEE J Biomed Health Inform 2018; 22:398-408. [DOI: 10.1109/jbhi.2017.2654683] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
5
|
Abstract
Electrocardiogram (ECG) signal quality assessment (SQA) plays a vital role in significantly improving the diagnostic accuracy and reliability of unsupervised ECG analysis systems. In practice, the ECG signal is often corrupted with different kinds of noises and artifacts. Therefore, numerous SQA methods were presented based on the ECG signal and/or noise features and the machine learning classifiers and/or heuristic decision rules. This paper presents an overview of current state-of-the-art SQA methods and highlights the practical limitations of the existing SQA methods. Based upon past and our studies, it is noticed that a lightweight ECG noise analysis framework is highly demanded for real-time detection, localization, and classification of single and combined ECG noises within the context of wearable ECG monitoring devices which are often resource constrained.
Collapse
|
6
|
Satija U, Ramkumar B, Sabarimalai Manikandan M. Noise-aware dictionary-learning-based sparse representation framework for detection and removal of single and combined noises from ECG signal. Healthc Technol Lett 2017; 4:2-12. [PMID: 28529758 PMCID: PMC5435964 DOI: 10.1049/htl.2016.0077] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2016] [Revised: 11/27/2016] [Accepted: 12/08/2016] [Indexed: 11/24/2022] Open
Abstract
Automatic electrocardiogram (ECG) signal enhancement has become a crucial pre-processing step in most ECG signal analysis applications. In this Letter, the authors propose an automated noise-aware dictionary learning-based generalised ECG signal enhancement framework which can automatically learn the dictionaries based on the ECG noise type for effective representation of ECG signal and noises, and can reduce the computational load of sparse representation-based ECG enhancement system. The proposed framework consists of noise detection and identification, noise-aware dictionary learning, sparse signal decomposition and reconstruction. The noise detection and identification is performed based on the moving average filter, first-order difference, and temporal features such as number of turning points, maximum absolute amplitude, zerocrossings, and autocorrelation features. The representation dictionary is learned based on the type of noise identified in the previous stage. The proposed framework is evaluated using noise-free and noisy ECG signals. Results demonstrate that the proposed method can significantly reduce computational load as compared with conventional dictionary learning-based ECG denoising approaches. Further, comparative results show that the method outperforms existing methods in automatically removing noises such as baseline wanders, power-line interference, muscle artefacts and their combinations without distorting the morphological content of local waves of ECG signal.
Collapse
Affiliation(s)
- Udit Satija
- School of Electrical Sciences, Indian Institute of Technology Bhubaneswar, Bhubaneswar, Odisha 751013, India
| | - Barathram Ramkumar
- School of Electrical Sciences, Indian Institute of Technology Bhubaneswar, Bhubaneswar, Odisha 751013, India
| | - M. Sabarimalai Manikandan
- School of Electrical Sciences, Indian Institute of Technology Bhubaneswar, Bhubaneswar, Odisha 751013, India
| |
Collapse
|
7
|
Prabhakararao E, Manikandan MS. Efficient and robust ventricular tachycardia and fibrillation detection method for wearable cardiac health monitoring devices. Healthc Technol Lett 2016; 3:239-246. [PMID: 27733933 PMCID: PMC5047284 DOI: 10.1049/htl.2016.0010] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2016] [Revised: 06/15/2016] [Accepted: 06/16/2016] [Indexed: 11/20/2022] Open
Abstract
In this Letter, the authors propose an efficient and robust method for automatically determining the VT and VF events in the electrocardiogram (ECG) signal. The proposed method consists of: (i) discrete cosine transform (DCT)-based noise suppression; (ii) addition of bipolar sequence of amplitudes with alternating polarity; (iii) zero-crossing rate (ZCR) estimation-based VTVF detection; and (iv) peak-to-peak interval (PPI) feature based VT/VF discrimination. The proposed method is evaluated using 18,000 episodes of different ECG arrhythmias taken from 6 PhysioNet databases. The method achieves an average sensitivity (Se) of 99.61%, specificity (Sp) of 99.96%, and overall accuracy (OA) of 99.92% in detecting VTVF and non-VTVF episodes by using a ZCR feature. Results show that the method achieves a Se of 100%, Sp of 99.70% and OA of 99.85% for discriminating VT from VF episodes using PPI features extracted from the processed signal. The robustness of the method is tested using different kinds of ECG beats and various types of noises including the baseline wanders, powerline interference and muscle artefacts. Results demonstrate that the proposed method with the ZCR, PPI features can achieve significantly better detection rates as compared with the existing methods.
Collapse
Affiliation(s)
- Eedara Prabhakararao
- School of Electrical Sciences, Indian Institute of Technology Bhubaneswar, Bhubaneswar, Odisha 751013, India
| | - M. Sabarimalai Manikandan
- School of Electrical Sciences, Indian Institute of Technology Bhubaneswar, Bhubaneswar, Odisha 751013, India
| |
Collapse
|
8
|
Satija U, Ramkumar B, Manikandan MS. Robust cardiac event change detection method for long-term healthcare monitoring applications. Healthc Technol Lett 2016; 3:116-23. [PMID: 27382480 DOI: 10.1049/htl.2015.0062] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2015] [Revised: 03/14/2016] [Accepted: 04/05/2016] [Indexed: 11/19/2022] Open
Abstract
A long-term continuous cardiac health monitoring system highly demands more battery power for real-time transmission of electrocardiogram (ECG) signals and increases bandwidth, treatment costs and traffic load of the diagnostic server. In this Letter, the authors present an automated low-complexity robust cardiac event change detection (CECD) method that can continuously detect specific changes in PQRST morphological patterns and heart rhythms and then enable transmission/storing of the recorded ECG signals. The proposed CECD method consists of four stages: ECG signal quality assessment, R-peak detection and beat waveform extraction, temporal and RR interval feature extraction and cardiac event change decision. The proposed method is tested and validated using both normal and abnormal ECG signals including different types of arrhythmia beats, heart rates and signal quality. Results show that the method achieves an average sensitivity of 99.76%, positive predictivity of 94.58% and overall accuracy of 94.32% in determining the changes in heartbeat waveforms of the ECG signals.
Collapse
Affiliation(s)
- Udit Satija
- School of Electrical Sciences , Indian Institute of Technology Bhubaneswar , Bhubaneswar, Odisha-751013 , India
| | - Barathram Ramkumar
- School of Electrical Sciences , Indian Institute of Technology Bhubaneswar , Bhubaneswar, Odisha-751013 , India
| | - M Sabarimalai Manikandan
- School of Electrical Sciences , Indian Institute of Technology Bhubaneswar , Bhubaneswar, Odisha-751013 , India
| |
Collapse
|
9
|
Manikandan MS, Ramkumar B, Deshpande PS, Choudhary T. Robust detection of premature ventricular contractions using sparse signal decomposition and temporal features. Healthc Technol Lett 2015; 2:141-8. [PMID: 26713158 PMCID: PMC4678438 DOI: 10.1049/htl.2015.0006] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2015] [Revised: 09/03/2015] [Accepted: 09/04/2015] [Indexed: 11/20/2022] Open
Abstract
An automated noise-robust premature ventricular contraction (PVC) detection method is proposed based on the sparse signal decomposition, temporal features, and decision rules. In this Letter, the authors exploit sparse expansion of electrocardiogram (ECG) signals on mixed dictionaries for simultaneously enhancing the QRS complex and reducing the influence of tall P and T waves, baseline wanders, and muscle artefacts. They further investigate a set of ten generalised temporal features combined with decision-rule-based detection algorithm for discriminating PVC beats from non-PVC beats. The accuracy and robustness of the proposed method is evaluated using 47 ECG recordings from the MIT/BIH arrhythmia database. Evaluation results show that the proposed method achieves an average sensitivity of 89.69%, and specificity 99.63%. Results further show that the proposed decision-rule-based algorithm with ten generalised features can accurately detect different patterns of PVC beats (uniform and multiform, couplets, triplets, and ventricular tachycardia) in presence of other normal and abnormal heartbeats.
Collapse
Affiliation(s)
- M. Sabarimalai Manikandan
- School of Electrical Sciences, Indian Institute of Technology Bhubaneswar, Bhubaneswar, Odisha 751013, India
| | - Barathram Ramkumar
- School of Electrical Sciences, Indian Institute of Technology Bhubaneswar, Bhubaneswar, Odisha 751013, India
| | - Pranav S. Deshpande
- School of Electrical Sciences, Indian Institute of Technology Bhubaneswar, Bhubaneswar, Odisha 751013, India
| | - Tilendra Choudhary
- School of Electrical Sciences, Indian Institute of Technology Bhubaneswar, Bhubaneswar, Odisha 751013, India
| |
Collapse
|
10
|
Kambhampati SS, Singh V, Manikandan MS, Ramkumar B. Unified framework for triaxial accelerometer-based fall event detection and classification using cumulants and hierarchical decision tree classifier. Healthc Technol Lett 2015; 2:101-7. [PMID: 26609414 DOI: 10.1049/htl.2015.0018] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2015] [Revised: 06/22/2015] [Accepted: 06/22/2015] [Indexed: 11/19/2022] Open
Abstract
In this Letter, the authors present a unified framework for fall event detection and classification using the cumulants extracted from the acceleration (ACC) signals acquired using a single waist-mounted triaxial accelerometer. The main objective of this Letter is to find suitable representative cumulants and classifiers in effectively detecting and classifying different types of fall and non-fall events. It was discovered that the first level of the proposed hierarchical decision tree algorithm implements fall detection using fifth-order cumulants and support vector machine (SVM) classifier. In the second level, the fall event classification algorithm uses the fifth-order cumulants and SVM. Finally, human activity classification is performed using the second-order cumulants and SVM. The detection and classification results are compared with those of the decision tree, naive Bayes, multilayer perceptron and SVM classifiers with different types of time-domain features including the second-, third-, fourth- and fifth-order cumulants and the signal magnitude vector and signal magnitude area. The experimental results demonstrate that the second- and fifth-order cumulant features and SVM classifier can achieve optimal detection and classification rates of above 95%, as well as the lowest false alarm rate of 1.03%.
Collapse
Affiliation(s)
- Satya Samyukta Kambhampati
- School of Electrical Sciences , Indian Institute of Technology Bhubaneswar , Bhubaneswar, Odisha 751013 , India
| | - Vishal Singh
- School of Electrical Sciences , Indian Institute of Technology Bhubaneswar , Bhubaneswar, Odisha 751013 , India
| | - M Sabarimalai Manikandan
- School of Electrical Sciences , Indian Institute of Technology Bhubaneswar , Bhubaneswar, Odisha 751013 , India
| | - Barathram Ramkumar
- School of Electrical Sciences , Indian Institute of Technology Bhubaneswar , Bhubaneswar, Odisha 751013 , India
| |
Collapse
|
11
|
Manikandan MS, Ramkumar B. Straightforward and robust QRS detection algorithm for wearable cardiac monitor. Healthc Technol Lett 2014; 1:40-4. [PMID: 26609375 DOI: 10.1049/htl.2013.0019] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2013] [Revised: 12/26/2013] [Accepted: 02/05/2014] [Indexed: 11/19/2022] Open
Abstract
This Letter presents a fairly straightforward and robust QRS detector for wearable cardiac monitoring applications. The first stage of the QRS detector contains a powerful ℓ1-sparsity filter with overcomplete hybrid dictionaries for emphasising the QRS complexes and suppressing the baseline drifts, powerline interference and large P/T waves. The second stage is a simple peak-finding logic based on the Gaussian derivative filter for automatically finding locations of R-peaks in the ECG signal. Experiments on the standard MIT-BIH arrythmia database show that the method achieves an average sensitivity of 99.91% and positive predictivity of 99.92%. Unlike existing methods, the proposed method improves detection performance under small-QRS, wide-QRS complexes and noisy conditions without using the searchback algorithms.
Collapse
Affiliation(s)
- M Sabarimalai Manikandan
- School of Electrical Sciences , Indian Institute of Technology Bhubaneswar , Bhubaneswar , Odisha-751013 , India
| | - Barathram Ramkumar
- School of Electrical Sciences , Indian Institute of Technology Bhubaneswar , Bhubaneswar , Odisha-751013 , India
| |
Collapse
|
12
|
|