1
|
Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators. EJNMMI Phys 2023; 10:62. [PMID: 37819578 PMCID: PMC10567620 DOI: 10.1186/s40658-023-00572-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Accepted: 08/08/2023] [Indexed: 10/13/2023] Open
Abstract
BACKGROUND Alongside the benefits of Total-Body imaging modalities, such as higher sensitivity, single-bed position, low dose imaging, etc., their final construction cost prevents worldwide utilization. The main aim of this study is to present a simulation-based comparison of the sensitivities of existing and currently developed tomographs to introduce a cost-efficient solution for constructing a Total-Body PET scanner based on plastic scintillators. METHODS For the case of this study, eight tomographs based on the uEXPLORER configuration with different scintillator materials (BGO, LYSO), axial field-of-view (97.4 cm and 194.8 cm), and detector configurations (full and sparse) were simulated. In addition, 8 J-PET scanners with different configurations, such as various axial field-of-view (200 cm and 250 cm), different cross sections of plastic scintillator, and multiple numbers of plastic scintillator layers (2, 3, and 4), based on J-PET technology have been simulated by GATE software. Furthermore, Siemens' Biograph Vision has been simulated to compare the results with standard PET scans. Two types of simulations have been performed. The first one with a centrally located source with a diameter of 1 mm and a length of 250 cm, and the second one with the same source inside a water-filled cylindrical phantom with a diameter of 20 cm and a length of 183 cm. RESULTS With regards to sensitivity, among all the proposed scanners, the ones constructed with BGO crystals give the best performance ([Formula: see text] 350 cps/kBq at the center). The utilization of sparse geometry or LYSO crystals significantly lowers the achievable sensitivity of such systems. The J-PET design gives a similar sensitivity to the sparse LYSO crystal-based detectors while having full detector coverage over the body. Moreover, it provides uniform sensitivity over the body with additional gain on its sides and provides the possibility for high-quality brain imaging. CONCLUSION Taking into account not only the sensitivity but also the price of Total-Body PET tomographs, which till now was one of the main obstacles in their widespread clinical availability, the J-PET tomography system based on plastic scintillators could be a cost-efficient alternative for Total-Body PET scanners.
Collapse
|
2
|
Efficiency determination of J-PET: first plastic scintillators-based PET scanner. EJNMMI Phys 2023; 10:28. [PMID: 37029849 PMCID: PMC10082891 DOI: 10.1186/s40658-023-00546-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 03/22/2023] [Indexed: 04/09/2023] Open
Abstract
BACKGROUND The Jagiellonian Positron Emission Tomograph is the 3-layer prototype of the first scanner based on plastic scintillators, consisting of 192 half-metre-long strips with readouts at both ends. Compared to crystal-based detectors, plastic scintillators are several times cheaper and could be considered as a more economical alternative to crystal scintillators in future PETs. JPET is also a first multi-photon PET prototype. For the development of multi-photon detection, with photon characterized by the continuous energy spectrum, it is important to estimate the efficiency of J-PET as a function of energy deposition. The aim of this work is to determine the registration efficiency of the J-PET tomograph as a function of energy deposition by incident photons and the intrinsic efficiency of the J-PET scanner in detecting photons of different incident energies. In this study, 3-hit events are investigated, where 2-hits are caused by 511 keV photons emitted in [Formula: see text] annihilations, while the third hit is caused by one of the scattered photons. The scattered photon is used to accurately measure the scattering angle and thus the energy deposition. Two hits by a primary and a scattered photon are sufficient to calculate the scattering angle of a photon, while the third hit ensures the precise labeling of the 511 keV photons. RESULTS By comparing experimental and simulated energy distribution spectra, the registration efficiency of the J-PET scanner was determined in the energy deposition range of 70-270 keV, where it varies between 20 and 100[Formula: see text]. In addition, the intrinsic efficiency of the J-PET was also determined as a function of the energy of the incident photons. CONCLUSION A method for determining registration efficiency as a function of energy deposition and intrinsic efficiency as a function of incident photon energy of the J-PET scanner was demonstrated. This study is crucial for evaluating the performance of the scanner based on plastic scintillators and its applications as a standard and multi-photon PET systems. The method may be also used in the calibration of Compton-cameras developed for the ion-beam therapy monitoring and simultaneous multi-radionuclide imaging in nuclear medicine.
Collapse
|
3
|
TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2023. [DOI: 10.1109/trpms.2023.3243735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/11/2023]
|
4
|
Main Features of the SIDDHARTA-2 Apparatus for Kaonic Deuterium X-Ray Measurements. EPJ WEB OF CONFERENCES 2022. [DOI: 10.1051/epjconf/202226201016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
The low-energy, non-perturbative regime of QCD can be studied directly by X-ray spectroscopy of light kaonic atoms. The SIDDHARTA-2 experiment, located at the DAΦNE collider, aims to measure the 2p → 1s transition in kaonic deuterium for the first time to extract the antikaon-nucleon scattering lengths. This measurement is impeded, inter alia, by the low K−d X-ray yield. Hence, several updates have been implemented on the apparatus to increase the signal-to-background ratio, which are discussed in detail in this paper: a lightweight gas target cell, novel Silicon Drift Detectors for the X-ray detection with excellent performance, and a veto system for active background suppression. The experiment has undergone a first preparatory run during DAΦNE’s commissioning phase in 2021, concluding with a successful kaonic helium measurement.
Collapse
|
5
|
Trigger rejection factor in the first kaonic helium run with the complete SIDDHARTA-2 setup. EPJ WEB OF CONFERENCES 2022. [DOI: 10.1051/epjconf/202227000028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
The SIDDHARTA-2 experiment aims to perform the first measurement of the kaonic deuterium 2p → 1s x-ray transition energy. Such measurement, together with the measurement of kaonic hydrogen 2p → 1s x-ray energy transition performed by the SIDDHARTA experiment in 2011, allows the determination of kaon proton and kaon neutron scattering lengths and represents a fundamental input for the low energies QCD in the strangeness sector theory. The SIDDHARTA-2 experiment is presently installed at the DAΦNE electronpositron collider at the National Laboratories of Frascati, in Italy. In May 2022, the kaonic 4He x-ray transitions measurement was performed by the complete SIDDHARTA-2 setup, by using a gaseous target. The result of this measurement is presented in this paper, with a specific focus on the background rejection performed by the kaon trigger system.
Collapse
|
6
|
Investigation of novel preclinical Total Body PET designed with J-PET technology: A simulation study. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2022. [DOI: 10.1109/trpms.2022.3211780] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
7
|
Testing CPT symmetry in ortho-positronium decays with positronium annihilation tomography. Nat Commun 2021; 12:5658. [PMID: 34580294 PMCID: PMC8476595 DOI: 10.1038/s41467-021-25905-9] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Accepted: 09/06/2021] [Indexed: 11/16/2022] Open
Abstract
Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron–positron bound state (positronium atom) motivate further investigation, including fundamental symmetry tests. While CPT noninvariance effects could be manifested in non-vanishing angular correlations between final-state photons and spin of annihilating positronium, measurements were previously limited by knowledge of the latter. Here, we demonstrate tomographic reconstruction techniques applied to three-photon annihilations of ortho-positronium atoms to estimate their spin polarisation without magnetic field or polarised positronium source. We use a plastic-scintillator-based positron-emission-tomography scanner to record ortho-positronium (o-Ps) annihilations with single-event estimation of o-Ps spin and determine the complete spectrum of an angular correlation operator sensitive to CPT-violating effects. We find no violation at the precision level of 10−4, with an over threefold improvement on the previous measurement. CPT violation could manifest itself in annihilating positronium events, but searching for this effect would require to know the spin of the annihilating system. Here, the authors do this using a positron-emission tomography scanner, finding no violation with a statistical precision of 10−4.
Collapse
|
8
|
3D TOF-PET image reconstruction using total variation regularization. Phys Med 2020; 80:230-242. [DOI: 10.1016/j.ejmp.2020.10.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Revised: 10/09/2020] [Accepted: 10/14/2020] [Indexed: 12/31/2022] Open
|
9
|
Hit-Time and Hit-Position Reconstruction in Strips of Plastic Scintillators Using Multithreshold Readouts. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2020. [DOI: 10.1109/trpms.2020.2990621] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
10
|
Performance assessment of the 2 γpositronium imaging with the total-body PET scanners. EJNMMI Phys 2020; 7:44. [PMID: 32607664 PMCID: PMC7326848 DOI: 10.1186/s40658-020-00307-w] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2019] [Accepted: 05/17/2020] [Indexed: 02/01/2023] Open
Abstract
Purpose In living organisms, the positron-electron annihilation (occurring during the PET imaging) proceeds in about 30% via creation of a metastable ortho-positronium atom. In the tissue, due to the pick-off and conversion processes, over 98% of ortho-positronia annihilate into two 511 keV photons. In this article, we assess the feasibility for reconstruction of the mean ortho-positronium lifetime image based on annihilations into two photons. The main objectives of this work include the (i) estimation of the sensitivity of the total-body PET scanners for the ortho-positronium mean lifetime imaging using 2γ annihilations and (ii) estimation of the spatial and time resolution of the ortho-positronium image as a function of the coincidence resolving time (CRT) of the scanner. Methods Simulations are conducted assuming that radiopharmaceutical is labeled with 44Sc isotope emitting one positron and one prompt gamma. The image is reconstructed on the basis of triple coincidence events. The ortho-positronium lifetime spectrum is determined for each voxel of the image. Calculations were performed for cases of total-body detectors build of (i) LYSO scintillators as used in the EXPLORER PET and (ii) plastic scintillators as anticipated for the cost-effective total-body J-PET scanner. To assess the spatial and time resolution, the four cases were considered assuming that CRT is equal to 500 ps, 140 ps, 50 ps, and 10 ps. Results The estimated total-body PET sensitivity for the registration and selection of image forming triple coincidences (2γ+γprompt) is larger by a factor of 13.5 (for LYSO PET) and by factor of 5.2 (for plastic PET) with respect to the sensitivity for the standard 2γ imaging by LYSO PET scanners with AFOV = 20 cm. The spatial resolution of the ortho-positronium image is comparable with the resolution achievable when using TOF-FBP algorithms already for CRT = 50 ps. For the 20-min scan, the resolution better than 20 ps is expected for the mean ortho-positronium lifetime image determination. Conclusions Ortho-positronium mean lifetime imaging based on the annihilations into two photons and prompt gamma is shown to be feasible with the advent of the high sensitivity total-body PET systems and time resolution of the order of tens of picoseconds.
Collapse
|
11
|
Abstract
A detection system of the conventional PET tomograph is set-up to record data from [Formula: see text] annihilation into two photons with energy of 511 keV, and it gives information on the density distribution of a radiopharmaceutical in the body of the object. In this paper we explore the possibility of performing the three gamma photons imaging based on ortho-positronium annihilation, as well as the possibility of positronium mean lifetime imaging with the J-PET tomograph constructed from plastic scintillators. For this purposes simulations of the ortho-positronium formation and its annihilation into three photons were performed taking into account distributions of photons' momenta as predicted by the theory of quantum electrodynamics and the response of the J-PET tomograph. In order to test the proposed ortho-positronium lifetime image reconstruction method, we concentrate on the decay of the ortho-positronium into three photons and applications of radiopharmaceuticals labeled with isotopes emitting a prompt gamma. The proposed method of imaging is based on the determination of hit-times and hit-positions of registered photons which enables the reconstruction of the time and position of the annihilation point as well as the lifetime of the ortho-positronium on an event-by-event basis. We have simulated the production of the positronium in point-like sources and in a cylindrical phantom composed of a set of different materials in which the ortho-positronium lifetime varied from 2.0 ns to 3.0 ns, as expected for ortho-positronium created in the human body. The presented reconstruction method for total-body J-PET like detector allows to achieve a mean lifetime resolution of ∼40 ps. Recent positron annihilation lifetime spectroscopy measurements of cancerous and healthy uterine tissues show that this sensitivity may allow to study the morphological changes in cell structures.
Collapse
|
12
|
Λp correlated production from low energy K −12C interactions by AMADEUS. EPJ WEB OF CONFERENCES 2019. [DOI: 10.1051/epjconf/201919903010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
The main steps for the analysis of the Λp correlated production in low-energy K− captures on Carbon nuclei, performed by the AMADEUS collaboration, are presented. The goal is to perform the first comprehensive study of the K− absorption on two, three and four nucleons, exploiting the lowmomentum K−s (pK ~ 127 MeV/c) produced at the DAΦNE collider, and to measure the low-energy cross sections and branching ratios of the K− multinucleon absorption processes in both the Λp and Σ0p channels. An integrated luminosity of 1.74 fb−1 collected during the KLOE 2004/2005 data campaign is analysed by reconstructing the Λp final state.
Collapse
|
13
|
Abstract
The interaction of antikaons (K−) with nucleons and nuclei in the low-energy regime represents a very active research field in hadron physics. A unique and rather direct experimental access to the antikaon-nucleon scattering lengths is provided by precision X-ray spectroscopy of transitions in low-lying states in the lightest kaonic atoms (i.e. kaonic hydrogen and deuterium). In the SIDDHARTA experiment at the electron-positron collider DAFNE of LNFINFN we measured the most precise values of the strong interaction observables in conic hydrogen. The strong interaction on the 1s ground state of the electromagnetically bound K-p atom causes an energy shift and broadening of the 1s state. SIDDHARTA will extend the spectroscopy to kaonic deuterium to get access to the antikaon-neutron interaction and thus the isospin dependent scattering lengths. At J-PARC a kaon beam is used in a complementary experiment with a different setup for spectroscopy of kaonic deuterium atoms. The talk will give an overview of the of the upcoming experiments SIDDHARTA and the complementary experiment at J-PARC.Furthermore, the implications of the experiments for the theory of low-energy strong interaction with strangeness will be discussed.
Collapse
|
14
|
Low Energy Antikaon-nucleon/nuclei interaction studies by AMADEUS. EPJ WEB OF CONFERENCES 2019. [DOI: 10.1051/epjconf/201919901014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
The AMADEUS experiment at the DAΦNE collider of LNF-INFN deals with the investigation of the at-rest, or low-momentum, K− interactions in light nuclear targets, with the aim to constrain the low energy QCD models in the strangeness sector. The 0 step of the experiment consisted in the reanalysis of the 2004/2005 KLOE data, exploiting K− absorptions in H, 4He, 9Be and 12C, leading to the first invariant mass spectroscopic study with very low momentum (about 100 MeV) in-flight K− captures. With AMADEUS step 1 a dedicated pure Carbon target was implemented in the central region of the KLOE detector, providing a high statistic sample of pure at-rest K− nuclear interaction. The first measurement of the non-resonant transition amplitude $\left| {{A_{{K^ - }n \to \Lambda {\pi ^ - }}}} \right|$ at $\sqrt s = 33\,MeV$ below the K̄N threshold is presented, in relation with the Λ(1405) properties studies. The analysis procedure adopted in the serarch for K− multi-nucleon absorption cross sections and Branching Ratios will be also described.
Collapse
|
15
|
Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS 2018; 78:970. [PMID: 30636927 PMCID: PMC6315056 DOI: 10.1140/epjc/s10052-018-6461-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2018] [Accepted: 11/14/2018] [Indexed: 05/25/2023]
Abstract
J-PET is a detector optimized for registration of photons from the electron-positron annihilation via plastic scintillators where photons interact predominantly via Compton scattering. Registration of both primary and scattered photons enables to determinate the linear polarization of the primary photon on the event by event basis with a certain probability. Here we present quantitative results on the feasibility of such polarization measurements of photons from the decay of positronium with the J-PET and explore the physical limitations for the resolution of the polarization determination of 511 keV photons via Compton scattering. For scattering angles of about 82∘ (where the best contrast for polarization measurement is theoretically predicted) we find that the single event resolution for the determination of the polarization is about 40∘ (predominantly due to properties of the Compton effect). However, for samples larger than ten thousand events the J-PET is capable of determining relative average polarization of these photons with the precision of about few degrees. The obtained results open new perspectives for studies of various physics phenomena such as quantum entanglement and tests of discrete symmetries in decays of positronium and extend the energy range of polarization measurements by five orders of magnitude beyond the optical wavelength regime.
Collapse
|
16
|
Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA SoC Devices. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:2526-2535. [PMID: 29994248 DOI: 10.1109/tmi.2018.2837741] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
A novel approach to tomographic data processing has been developed and evaluated using the Jagiellonian positron emission tomography scanner as an example. We propose a system in which there is no need for powerful, local to the scanner processing facility, capable to reconstruct images on the fly. Instead, we introduce a field programmable gate array system-on-chip platform connected directly to data streams coming from the scanner, which can perform event building, filtering, coincidence search, and region-of-response reconstruction by the programmable logic and visualization by the integrated processors. The platform significantly reduces data volume converting raw data to a list-mode representation, while generating visualization on the fly.
Collapse
|
17
|
Estimating the NEMA characteristics of the J-PET tomograph using the GATE package. ACTA ACUST UNITED AC 2018; 63:165008. [DOI: 10.1088/1361-6560/aad29b] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
18
|
Isotensor Dibaryon in the pp→ppπ^{+}π^{-} Reaction? PHYSICAL REVIEW LETTERS 2018; 121:052001. [PMID: 30118290 DOI: 10.1103/physrevlett.121.052001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2018] [Revised: 04/19/2018] [Indexed: 06/08/2023]
Abstract
Exclusive measurements of the quasifree pp→ppπ^{+}π^{-} reaction have been carried out at WASA@COSY by means of pd collisions at T_{p}=1.2 GeV. Total and differential cross sections have been extracted covering the energy region T_{p}=1.08-1.36 GeV, which is the region of N^{*}(1440) and Δ(1232)Δ(1232) resonance excitations. Calculations describing these excitations by t-channel meson exchange are at variance with the measured differential cross sections and underpredict substantially the experimental total cross section. An isotensor ΔN dibaryon resonance with I(J^{P})=2(1^{+}) produced associatedly with a pion is able to overcome these deficiencies.
Collapse
|
19
|
Spin Dependence of η Meson Production in Proton-Proton Collisions Close to Threshold. PHYSICAL REVIEW LETTERS 2018; 120:022002. [PMID: 29376676 DOI: 10.1103/physrevlett.120.022002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2017] [Revised: 11/03/2017] [Indexed: 06/07/2023]
Abstract
Taking advantage of the high acceptance and axial symmetry of the WASA-at-COSY detector, and the high polarization degree of the proton beam of COSY, the reaction p[over →]p→ppη has been measured close to threshold to explore the analyzing power A_{y}. The angular distribution of A_{y} is determined with the precision improved by more than 1 order of magnitude with respect to previous results, allowing a first accurate comparison with theoretical predictions. The determined analyzing power is consistent with zero for an excess energy of Q=15 MeV, signaling s-wave production with no evidence for higher partial waves. At Q=72 MeV the data reveal strong interference of Ps and Pp partial waves and cancellation of (Pp)^{2} and Ss^{*}Sd contributions. These results rule out the presently available theoretical predictions for the production mechanism of the η meson.
Collapse
|
20
|
Studies of low-energy K - nuclear interactions by AMADEUS. EPJ WEB OF CONFERENCES 2018. [DOI: 10.1051/epjconf/201818202035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
The goal of the AMADEUS experiment is to shed light on unsolved fundamental issues in the non-perturbative strangeness QCD sector through the study of lowenergy K- hadronic interactions with light nuclear targets. The main open questions are the controversial nature of the Δ(1405) state, which is investigated in hyperon-pion correlation studies, and the possible existence of exotic antikaon multi-nucleon clusters, whose search in K- induced reactions is intimately related to the studies of the K- multi-nucleon absorption processes in hyperon-nucleon/nucleus channels. The DAΦNE collider at the INFN-LNF provides unique monochromatic low-momentum kaons from the φ meson decay almost at-rest, suitable for the AMADEUS studies. The KLOE detector is exploited as an active target, in order to obtain excellent acceptance and resolution data for K- nuclear capture on H, 4He, 9Be and 12C, both at-rest and in-flight.
Collapse
|
21
|
Low energy interaction studies of negative kaons in light nuclear targets by AMADEUS. EPJ WEB OF CONFERENCES 2018. [DOI: 10.1051/epjconf/201818101005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
The AMADEUS collaboration is performing experimental investigations in the sector of the low energy strangeness hadron physics by taking advantage of the DAΦNE collider, which provides a unique source of monochromatic low-momentum kaons and exploiting the KLOE detector as an active target. The K− single and multi-nuclear absorption on H, 4He, 9Be and 12C, both at-rest and in-flight, are studied with the aim to determine the nature of the controversial Λ(1405), the non-resonant hyperon pion formation amplitude below the K̅N threshold, the yield and cross sections of K− multi-nucleon absorptions intimately connected to the antikaon multi-nucleon clusters properties and the K− scattering cross sections on light nuclear targets.
These studies have a strong impact on the non-perturbative strangeness QCD with implications ranging from nuclear physics to the equation of state of neutron stars.
Collapse
|
22
|
Abstract
The interaction of antikaons with nucleons and nuclei in the low-energy regime represents an active research field in hadron physics with still many important open questions. The investigation of light kaonic atoms, in which one electron is replaced by a negatively charged kaon, is a unique tool to provide precise information on this interaction; the energy shift and the broadening of the low-lying states of such atoms, induced by the kaon-nucleus hadronic interaction, can be determined with high precision from the atomic X-ray spectroscopy, and this experimental method provides unique information to understand the low energy kaon-nucleus interaction at the production threshold. The lightest atomic systems, like the kaonic hydrogen and the kaonic deuterium deliver, in a model-independent way, the isospin-dependent kaon-nucleon scattering lengths. The most precise kaonic hydrogen measurement to-date, together with an exploratory measurement of kaonic deuterium, were carried out in 2009 by the SIDDHARTA collaboration at the DAΦNE electron-positron collider of LNF-INFN, combining the excellent quality kaon beam delivered by the collider with new experimental techniques, as fast and very precise X-ray detectors, like the Silicon Drift Detectors. The SIDDHARTA results triggered new theoretical work, which achieved major progress in the understanding of the low-energy strong interaction with strangeness reflected by the antikaon-nucleon scattering lengths calculated with the antikaon-proton amplitudes constrained by the SIDDHARTA data. The most important open question is the experimental determination of the hadronic energy shift and width of kaonic deuterium; presently, a major upgrade of the setup, SIDDHARTA-2, is being realized to reach this goal. In this paper, the results obtained in 2009 and the proposed SIDDHARTA-2 upgrades are presented.
Collapse
|
23
|
Search for the 4He- ηbound state in dd→ ( 4He- η) bound→ 3He nπ0and dd→ ( 4He- η) bound→ 3He pπ−reactions with the WASA-at-COSY facility. EPJ WEB OF CONFERENCES 2014. [DOI: 10.1051/epjconf/20148102020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
24
|
Search for the η-mesic 4He with WASA-at-COSY. EPJ WEB OF CONFERENCES 2014. [DOI: 10.1051/epjconf/20146609009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
25
|
Search for the He- ηbound states with the WASA-at-COSY facility. EPJ WEB OF CONFERENCES 2012. [DOI: 10.1051/epjconf/20123709034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
26
|
Abashian-Booth-Crowe effect in basic double-pionic fusion: a new resonance? PHYSICAL REVIEW LETTERS 2011; 106:242302. [PMID: 21770567 DOI: 10.1103/physrevlett.106.242302] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2011] [Indexed: 05/31/2023]
Abstract
We report on an exclusive and kinematically complete high-statistics measurement of the basic double-pionic fusion reaction pn→dπ(0)π(0) over the full energy region of the ABC effect, a pronounced low-mass enhancement in the ππ-invariant mass spectrum. The measurements, which cover also the transition region to the conventional t-channel ΔΔ process, were performed with the upgraded WASA detector setup at COSY. The data reveal the Abashian-Booth-Crowe effect to be uniquely correlated with a Lorentzian energy dependence in the integral cross section. The observables are consistent with a narrow resonance with m=2.37 GeV, Γ≈70 MeV and I(J(P))=0(3(+)) in both pn and ΔΔ systems. Necessary further tests of the resonance interpretation are discussed.
Collapse
|
27
|
[The problem of metastasis to the lymph nodes in patients with carcinoma of the lower lip]. CZASOPISMO STOMATOLOGICZNE 1969; 22:745-9. [PMID: 5258122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
|
28
|
[Cancer of the lower lip]. POLSKI TYGODNIK LEKARSKI (WARSAW, POLAND : 1960) 1968; 23:1092-5. [PMID: 5688486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
|
29
|
[Evaluation of results of treatment of lower lip cancer with special emphasis on the primary changes, based on material from the District Oncological Center in Wrocław]. NOWOTWORY 1968; 18:197-204. [PMID: 5698326] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
|