1
|
Evaluation of an iterative model-based CT reconstruction algorithm by intra-patient comparison of standard and ultra-low-dose examinations. Acta Radiol 2018; 59:1225-1231. [PMID: 29320863 DOI: 10.1177/0284185117752551] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Background The explosive growth of computer tomography (CT) has led to a growing public health concern about patient and population radiation dose. A recently introduced technique for dose reduction, which can be combined with tube-current modulation, over-beam reduction, and organ-specific dose reduction, is iterative reconstruction (IR). Purpose To evaluate the quality, at different radiation dose levels, of three reconstruction algorithms for diagnostics of patients with proven liver metastases under tumor follow-up. Material and Methods A total of 40 thorax-abdomen-pelvis CT examinations acquired from 20 patients in a tumor follow-up were included. All patients were imaged using the standard-dose and a specific low-dose CT protocol. Reconstructed slices were generated by using three different reconstruction algorithms: a classical filtered back projection (FBP); a first-generation iterative noise-reduction algorithm (iDose4); and a next generation model-based IR algorithm (IMR). Results The overall detection of liver lesions tended to be higher with the IMR algorithm than with FBP or iDose4. The IMR dataset at standard dose yielded the highest overall detectability, while the low-dose FBP dataset showed the lowest detectability. For the low-dose protocols, a significantly improved detectability of the liver lesion can be reported compared to FBP or iDose4 ( P = 0.01). The radiation dose decreased by an approximate factor of 5 between the standard-dose and the low-dose protocol. Conclusion The latest generation of IR algorithms significantly improved the diagnostic image quality and provided virtually noise-free images for ultra-low-dose CT imaging.
Collapse
|
2
|
Volumetric gain of the human pancreas after left partial pancreatic resection: A CT-scan based retrospective study. Pancreatology 2015; 15:542-547. [PMID: 26145835 DOI: 10.1016/j.pan.2015.06.007] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2014] [Revised: 02/09/2015] [Accepted: 06/15/2015] [Indexed: 12/11/2022]
Abstract
BACKGROUND/OBJECTIVES Regeneration of the pancreas has been well characterized in animal models. However, there are conflicting data on the regenerative capacity of the human pancreas. The aim of the present study was to assess the regenerative capacity of the human pancreas. METHODS In a retrospective study, data from patients undergoing left partial pancreatic resection at a single center were eligible for inclusion (n = 185). Volumetry was performed based on 5 mm CT-scans acquired through a 256-slice CT-scanner using a semi-automated software. RESULTS Data from 24 patients (15 males/9 females) were included. Mean ± SD age was 68 ± 11 years (range, 40-85 years). Median time between surgery and the 1st postoperative CT was 9 days (range, 0-27 days; IQR, 7-13), 55 days (range, 21-141 days; IQR, 34-105) until the 2nd CT, and 191 days (range, 62-1902; IQR, 156-347) until the 3rd CT. The pancreatic volumes differed significantly between the first and the second postoperative CT scans (median volume 25.6 mL and 30.6 mL, respectively; p = 0.008) and had significantly increased further by the 3rd CT scan (median volume 37.9 mL; p = 0.001 for comparison with 1st CT scan and p = 0.003 for comparison with 2nd CT scan). CONCLUSIONS The human pancreas shows a measurable and considerable potential of volumetric gain after partial resection. Multidetector-CT based semi-automated volume analysis is a feasible method for follow-up of the volume of the remaining pancreatic parenchyma after partial pancreatectomy. Effects on exocrine and endocrine pancreatic function have to be evaluated in a prospective manner.
Collapse
|
3
|
Post-therapeutic response evaluation by a combination of endoscopy and CT scan in esophagogastric adenocarcinoma after chemotherapy: better than its reputation. Gastric Cancer 2015; 18:314-25. [PMID: 24722800 DOI: 10.1007/s10120-014-0367-x] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2013] [Accepted: 03/09/2014] [Indexed: 02/07/2023]
Abstract
BACKGROUND Neoadjuvant chemotherapy is an accepted standard of care for locally advanced esophagogastric cancer. As only a subgroup benefits, a response-based tailored treatment would be of interest. The aim of our study was the evaluation of the prognostic and predictive value of clinical response in esophagogastric adenocarcinomas. METHODS Clinical response based on a combination of endoscopy and computed tomography (CT) scan was evaluated retrospectively within a prospective database in center A and then transferred to center B. A total of 686/740 (A) and 184/210 (B) patients, staged cT3/4, cN0/1 underwent neoadjuvant chemotherapy and were then re-staged by endoscopy and CT before undergoing tumor resection. Of 184 patients, 118 (B) additionally had an interim response assessment 4-6 weeks after the start of chemotherapy. RESULTS In A, 479 patients (70%) were defined as clinical nonresponders, 207 (30%) as responders. Median survival was 38 months (nonresponders: 27 months, responders: 108 months, log-rank, p < 0.001). Clinical and histopathological response correlated significantly (p < 0.001). In multivariate analysis, clinical response was an independent prognostic factor (HR for death 1.4, 95% CI 1.0-1.8, p = 0.032). In B, 140 patients (76%) were nonresponders and 44 (24%) responded. Median survival was 33 months, (nonresponders: 27 months, responders: not reached, p = 0.003). Interim clinical response evaluation (118 patients) also had prognostic impact (p = 0.008). Interim, preoperative clinical response and histopathological response correlated strongly (p < 0.001). CONCLUSION Preoperative clinical response was an independent prognostic factor in center A, while in center B its prognostic value could only be confirmed in univariate analysis. The accordance with histopathological response was good in both centers, and interim clinical response evaluation showed comparable results to preoperative evaluation.
Collapse
|
4
|
Interim endoscopy results during neoadjuvant therapy for gastric cancer correlate with histopathological response and prognosis. Gastric Cancer 2015; 17:478-88. [PMID: 23996162 DOI: 10.1007/s10120-013-0296-0] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/18/2013] [Accepted: 08/14/2013] [Indexed: 02/07/2023]
Abstract
BACKGROUND Neoadjuvant chemotherapy for locally advanced gastric cancer leads to major histopathological response in less than 30 % of patients. Data on interim endoscopic response assessment do not exist. This exploratory prospective study evaluates early endoscopy after 50 % of the chemotherapy as predictor for later response and prognosis. METHODS Forty-seven consecutive patients were included (45 resected; 33 R0 resections). All patients received baseline endoscopy and CT scans, after 50 % of their chemotherapy (EGD-1, CT-1) and after completion of chemotherapy (EGD-2, CT-2). Interim endoscopic response (EGD-1) was assessed after having received 50 % (6 weeks) of the planned 12 weeks of neoadjuvant chemotherapy. Post-chemotherapy response was clinically assessed by a combination of CT scan (CT-2) and endoscopy (EGD-2). Histopathological response was determined by a standardized scoring system (Becker criteria). Endoscopic response was defined as a reduction of >75 % of the tumor mass. RESULTS Twelve patients were responders at EGD-1 and 13 at EGD-2. Nine patients (19.1 %) were clinical responders and 7 patients (15.6 %) were histopathological responders after chemotherapy. Specificity, accuracy, and negative predictive value of the interim EGD-1 for subsequent histopathological response were 31/38 (82 %), 36/47 (76 %), and 31/33 (93 %); and for recurrence or death, 28/30 (93.3 %), 38/47 (80.9 %), and 28/35 (80.0 %). Response at EGD-1 was significantly associated with histopathological response (p = 0.010), survival (p < 0.001), and recurrence-free survival (p = 0.009). CONCLUSIONS Interim endoscopy after 6 weeks predicts response and prognosis. Therefore, tailoring treatment according to interim endoscopic assessment could be feasible, but the findings of this study should be validated in a larger patient cohort.
Collapse
|
5
|
Evaluation of an iterative model-based reconstruction algorithm for low-tube-voltage (80 kVp) computed tomography angiography. J Med Imaging (Bellingham) 2014; 1:033501. [PMID: 26158054 DOI: 10.1117/1.jmi.1.3.033501] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2014] [Revised: 09/03/2014] [Accepted: 09/11/2014] [Indexed: 11/14/2022] Open
Abstract
The objective of this study was to investigate the improvement in diagnostic quality of an iterative model-based reconstruction (IMBR) algorithm for low-tube-voltage (80-kVp) and low-tube-current in abdominal computed tomography angiography (CTA). A total of 11 patients were imaged on a 256-slice multidetector computed tomography for visualization of the aorta. For all patients, three different reconstructions from the low-tube-voltage data are generated: filtered backprojection (FBP), IMBR, and a mixture of both [Formula: see text]. To determine the diagnostic value of IMBR-based reconstructions, the image quality was assessed. With IMBR-based reconstructions, image noise could be significantly reduced, which was confirmed by a highly improved contrast-to-noise ratio. In the image quality assessment, radiologists were able to reliably detect more third-order and higher aortic branches in the IMBR reconstructions compared to FBP reconstructions. The effective dose level was, on average, 3.0 mSv for 80-kVp acquisitions. Low-tube-voltage CTAs significantly improve vascular contrast as presented by others; however, this effect in combination with IMBR enabled yet another substantial improvement of diagnostic quality. For IMBR, a significant improvement of image quality and a decreased radiation dose at low-tube-voltage can be reported.
Collapse
|
6
|
Validation of a low dose simulation technique for computed tomography images. PLoS One 2014; 9:e107843. [PMID: 25247422 PMCID: PMC4172631 DOI: 10.1371/journal.pone.0107843] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2014] [Accepted: 08/21/2014] [Indexed: 02/02/2023] Open
Abstract
PURPOSE Evaluation of a new software tool for generation of simulated low-dose computed tomography (CT) images from an original higher dose scan. MATERIALS AND METHODS Original CT scan data (100 mAs, 80 mAs, 60 mAs, 40 mAs, 20 mAs, 10 mAs; 100 kV) of a swine were acquired (approved by the regional governmental commission for animal protection). Simulations of CT acquisition with a lower dose (simulated 10-80 mAs) were calculated using a low-dose simulation algorithm. The simulations were compared to the originals of the same dose level with regard to density values and image noise. Four radiologists assessed the realistic visual appearance of the simulated images. RESULTS Image characteristics of simulated low dose scans were similar to the originals. Mean overall discrepancy of image noise and CT values was -1.2% (range -9% to 3.2%) and -0.2% (range -8.2% to 3.2%), respectively, p>0.05. Confidence intervals of discrepancies ranged between 0.9-10.2 HU (noise) and 1.9-13.4 HU (CT values), without significant differences (p>0.05). Subjective observer evaluation of image appearance showed no visually detectable difference. CONCLUSION Simulated low dose images showed excellent agreement with the originals concerning image noise, CT density values, and subjective assessment of the visual appearance of the simulated images. An authentic low-dose simulation opens up opportunity with regard to staff education, protocol optimization and introduction of new techniques.
Collapse
|
7
|
Is preoperative chemotherapy followed by surgery the appropriate treatment for signet ring cell containing adenocarcinomas of the esophagogastric junction and stomach? Ann Surg Oncol 2014; 21:1739-48. [PMID: 24419755 DOI: 10.1245/s10434-013-3462-z] [Citation(s) in RCA: 60] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2013] [Indexed: 02/06/2023]
Abstract
BACKGROUND Recent data suggest primary resection as the preferable approach in patients with signet ring cell gastric cancer (SRC). The aim of our retrospective exploratory study was to evaluate the influence of SRC on prognosis and response in esophagogastric adenocarcinoma treated with neoadjuvant chemotherapy. METHODS A total of 723 locally advanced esophagogastric adenocarcinomas (cT3/4 N any) documented in a prospective database from two academic centers were classified according to the WHO definition for SRC (more than 50 % SRC) and analyzed for their association with response and prognosis after neoadjuvant treatment. RESULTS A total of 235 tumors (32.5 %) contained SRC. Median survival of SRC was 26.3 compared with 46.6 months (p < 0.001) for non-SRC. SRC were significantly associated with female gender, gastric localization, advanced ypT and R1/2 categories, and lower risk of surgical complications and anastomotic leakage (each p < 0.001). Clinical (21.1 vs. 33.7 %, p = 0.001) and histopathological response (less than 10 % residual tumor: 16.3 vs. 28.9 %, p < 0.001) were significantly less frequent in SRC. Clinical response (p = 0.003) and complete histopathological response (pCR) (3.4 %) (p = 0.003) were associated with improved prognosis in SRC. Clinical response, surgical complications, ypTN categories, but not SRC were independent prognostic factors in forward Cox regression analysis in R0 resected patients. Risk of peritoneal carcinomatosis was increased (p < 0.001), while local (p = 0.015) and distant metastases (p = 0.02) were less frequent than in non-SRC. CONCLUSIONS Prognosis of SRC is unfavorable. Although response to neoadjuvant chemotherapy is rare in SRC, it is associated with improved outcome. Thus, chemotherapy might not generally be abandoned in SRC. A stratification based on SRC should be included in clinical trials.
Collapse
|
8
|
Three-dimensional prediction of free-flap volume in autologous breast reconstruction by CT angiography imaging. Int J Comput Assist Radiol Surg 2013; 9:541-9. [PMID: 24091852 DOI: 10.1007/s11548-013-0941-4] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2013] [Accepted: 09/03/2013] [Indexed: 11/27/2022]
Abstract
PURPOSE The diagnostic use of computer tomography angiography (CTA) to identify perforating blood vessels for abdominal free-flap breast reconstruction was extended to estimate the three-dimensional (3D) preoperative flap volume and to compare it with the real intraoperative flap weights in order to (1) evaluate the accuracy of CTA-based 3D flap volume prediction, and (2) to analyze abdominal tissue estimation for required breast volume reconstruction. METHODS Preoperative CTA was performed in 54 patients undergoing unilateral breast reconstruction with a free, deep, inferior epigastric artery perforator flap. 3D flap volumes ([Formula: see text]) based on CTA data were calculated and compared with the actual intraoperative flap weight (g). In addition, a breast volume to flap volume ratio was calculated to analyze whether the estimated 3D abdominal flap volume would match that of the breast to be removed. RESULTS 40 CTA data sets (74.1 %) fulfilled the technical requirements for a reliable determination of flap volume. 3D CTA flap volume prediction showed no relevant differences to the actual flap weight (p = 0.44) and high correlations (r = 0.998, [Formula: see text]), allowing a prediction accuracy within 0.29 [Formula: see text] 3.0 % (range: from [Formula: see text]8.77 to 5.67 %) of the real flap weight. Significantly larger flap volumes were harvested compared with the actually required breast volumes ([Formula: see text]), leading to an average of 21 % of the remnant flap tissue potentially being discarded. CONCLUSIONS CTA-based 3D flap volume prediction provides accurate preoperative guidelines concerning the needed amount of abdominal tissue that can be harvested to achieve acceptable symmetry.
Collapse
|
9
|
Evaluation of a method for improving the detection of hepatocellular carcinoma. Eur Radiol 2013; 24:250-5. [PMID: 23996016 DOI: 10.1007/s00330-013-3006-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2013] [Revised: 07/27/2013] [Accepted: 08/13/2013] [Indexed: 12/22/2022]
Abstract
OBJECTIVE To improve the detection of liver lesions in patients with hepatocellular carcinoma (HCC) via an iodine contrast enhancement tool. METHODS Thirty-two patients with clinically proven HCCs underwent imaging with a three-phase protocol on a 256-slice MDCT. The contrast enhancement in the reconstructed slices was improved via a post-processing tool. Mean image noise was measured in four different regions: liver lesion, healthy liver, subcutaneous fat and bone. For each image set the image noise and contrast-to-noise ratio (CNR) were assessed. For subjective image assessment, four experienced radiologists evaluated the diagnostic quality. RESULTS While employing the post-processing algorithm, CNR between the liver lesion and healthy liver tissue improves significantly by a factor of 1.78 (CNRwithout vC = 2.30 ± 1.92/CNRwith vC = 4.11 ± 3.05) (P* = 0.01). All results could be achieved without a strengthening of artefacts; mean HU values of subcutaneous fat and bone did not significantly change. Subjective image analysis illustrated a significant improvement when employing post-processing for clinically relevant criteria such as diagnostic confidence. CONCLUSION With post-processing we see a significantly improved detection of arterial uptake in hepatic lesions compared with non-processed data. The improvement in CNR was confirmed by subjective image assessment for small lesions and for lesions with limited uptake. KEY POINTS • Enhancement with iodine-based contrast agents is an essential part of CT. • A new post-processing tool significantly improves the diagnostics of hepatocellular carcinoma. • It also improves detection of small lesions with limited iodine uptake.
Collapse
|
10
|
A reliable risk score for stage IV esophagogastric cancer. Eur J Surg Oncol 2013; 39:823-30. [DOI: 10.1016/j.ejso.2013.01.005] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2012] [Revised: 10/13/2012] [Accepted: 01/09/2013] [Indexed: 12/19/2022] Open
|
11
|
Whole-body CT in haemodynamically unstable severely injured patients--a retrospective, multicentre study. PLoS One 2013; 8:e68880. [PMID: 23894365 PMCID: PMC3722202 DOI: 10.1371/journal.pone.0068880] [Citation(s) in RCA: 160] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2013] [Accepted: 05/31/2013] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND The current common and dogmatic opinion is that whole-body computed tomography (WBCT) should not be performed in major trauma patients in shock. We aimed to assess whether WBCT during trauma-room treatment has any effect on the mortality of severely injured patients in shock. METHODS In a retrospective multicenter cohort study involving 16719 adult blunt major trauma patients we compared the survival of patients who were in moderate, severe or no shock (systolic blood pressure 90-110,<90 or >110 mmHg) at hospital admission and who received WBCT during resuscitation to those who did not. Using data derived from the 2002-2009 version of TraumaRegister®, we determined the observed and predicted mortality and calculated the standardized mortality ratio (SMR) as well as logistic regressions. FINDINGS 9233 (55.2%) of the 16719 patients received WBCT. The mean injury severity score was 28.8±12.1. The overall mortality rate was 17.4% (SMR = 0.85, 95%CI 0.81-0.89) for patients with WBCT and 21.4% (SMR = 0.98, 95%CI 0.94-1.02) for those without WBCT (p<0.001). 4280 (25.6%) patients were in moderate shock and 1821 (10.9%) in severe shock. The mortality rate for patients in moderate shock with WBCT was 18.1% (SMR 0.85, CI95% 0.78-0.93) compared to 22.6% (SMR 1.03, CI95% 0.94-1.12) to those without WBCT (p<0.001, p = 0.002 for the SMRs). The mortality rate for patients in severe shock with WBCT was 42.1% (SMR 0.99, CI95% 0.92-1.06) compared to 54.9% (SMR 1.10, CI95% 1.02-1.16) to those without WBCT (p<0.001, p = 0.049 for the SMRs). Adjusted logistic regression analyses showed that WBCT is an independent predictor for survival that significantly increases the chance of survival in patients in moderate shock (OR = 0.73; 95%CI 0.60-0.90, p = 0.002) as well as in severe shock (OR = 0.67; 95%CI 0.52-0.88, p = 0.004). The number needed to scan related to survival was 35 for all patients, 26 for those in moderate shock and 20 for those in severe shock. CONCLUSIONS WBCT during trauma resuscitation significantly increased the survival in haemodynamically stable as well as in haemodynamically unstable major trauma patients. Thus, the application of WBCT in haemodynamically unstable severely injured patients seems to be safe, feasible and justified if performed quickly within a well-structured environment and by a well-organized trauma team.
Collapse
|
12
|
Schnelle Bestimmung des Lebervolumens und Segmentierung anhand neuer Algorithmen. ROFO-FORTSCHR RONTG 2013. [DOI: 10.1055/s-0033-1346326] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
13
|
CTA: Iterative Rekonstruktion. ROFO-FORTSCHR RONTG 2013. [DOI: 10.1055/s-0033-1346005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
14
|
Further experience with the free soleus perforator flaps using CT-angiography as a planning tool – A preliminary study. J Craniomaxillofac Surg 2012; 40:e253-7. [DOI: 10.1016/j.jcms.2011.10.030] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2011] [Revised: 09/30/2011] [Accepted: 10/07/2011] [Indexed: 10/15/2022] Open
|
15
|
A method for improving iodine contrast enhancement in abdominal computed tomography: experimental study in a pig model. Eur Radiol 2012; 23:985-90. [PMID: 23080073 DOI: 10.1007/s00330-012-2668-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2012] [Revised: 08/21/2012] [Accepted: 09/03/2012] [Indexed: 11/24/2022]
Abstract
OBJECTIVES To investigate the improvement in diagnostic image quality of an iodine contrast enhancement tool in an animal model for computed tomography (CT). METHODS One pig was examined over several consecutive days with a CT system. The quantity of iodine as contrast medium (0.6-1.2 ml/kg) varied among different acquisitions. The contrast enhancement in the reconstructed slices was improved via a post-processing tool. The post-processing tool is an algorithm designed for enhancement of iodine contrast in CT data. Contrast-to-noise ratio (CNR), the detectability between soft-tissue and vascular structures, and quantitative image analysis were assessed. RESULTS When reducing the quantity of contrast medium, our subjective image quality assessment revealed that it is visually possible to generate similar enhancement with less iodine. This observation was confirmed quantitatively in our CNR results. While employing the algorithm, the CNR between vascular structures and subcutaneous fat significantly improved. For unenhanced regions, we identified no change in HU values and no significant strengthening of artefacts. CONCLUSIONS With post-processing there was a significantly improved diagnostic image quality compared with non-processed data. In particular, similar contrast enhancement could be achieved with a reduced quantity of contrast medium injected during the CT acquisition.
Collapse
|
16
|
How fibrosis influences imaging and surgical decisions in pancreatic cancer. Front Physiol 2012; 3:389. [PMID: 23060813 PMCID: PMC3462403 DOI: 10.3389/fphys.2012.00389] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2012] [Accepted: 09/11/2012] [Indexed: 12/16/2022] Open
Abstract
Our understanding of pancreatic ductal adenocarcinoma (PDAC) is shifting away from a disease of malignant ductal cells-only, toward a complex system where tumor evolution is a result of interaction of cancer cells with their microenvironment. This change has led to intensification of research focusing on the fibrotic stroma of PDAC. Pancreatic stellate cells (PSCs) are the main fibroblastic cells of the pancreas which are responsible for producing the desmoplasia in chronic pancreatitis (CP) and PDAC. Clinically, the effect of desmoplasia is two-sided; on the negative side it is a hurdle in the diagnosis of PDAC because the fibrosis in cancer resembles that of CP. It is also believed that PSCs and pancreatic fibrosis are partially responsible for the therapy resistance in pancreatic cancer. On the positive side, a fibrotic pancreas is safer to operate on compared to a fatty and soft pancreas which is prone for postoperative pancreatic fistula. In this review the impact of pancreatic fibrosis on diagnosis of pancreatic cancer and surgical decisions are discussed from a clinical point of view.
Collapse
|
17
|
Bone mineral density measurements of the proximal femur from routine contrast-enhanced MDCT data sets correlate with dual-energy X-ray absorptiometry. Eur Radiol 2012; 23:505-12. [PMID: 22932742 DOI: 10.1007/s00330-012-2629-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2012] [Revised: 07/13/2012] [Accepted: 07/25/2012] [Indexed: 01/15/2023]
Abstract
OBJECTIVES To evaluate the utility of femoral bone mineral density (BMD) measurements in routine contrast-enhanced multi-detector computed tomography (ceMDCT) using dual-energy X-ray absorptiometry (DXA) as the reference standard. METHODS Forty-one patients (33 women, 8 men) underwent DXA measurement of the proximal femur. Subsequently, transverse sections of routine ceMDCT of these patients were used to measure BMD of the femoral head and femoral neck. The MDCT-to-DXA conversion equations for BMD and T-score were calculated using linear regression analysis. The conversion equations were applied to the MDCT data sets of 382 patients (120 women, 262 men) of whom 74 had osteoporotic fractures. RESULTS A correlation coefficient of r = 0.84 (P < 0.05) was calculated for BMD(MDCT) values of the femoral head and DXA T-scores of the total proximal femur using the conversion equation T-score = 0.021 × BMD(MDCT) - 5.90. The correlation coefficient for the femoral neck was r = 0.79 (P < 0.05) with the conversion equation T-score = 0.016 × BMD(MDCT) - 4.28. Accordingly, converted T-scores for the femoral neck in patients with versus those without osteoporotic fractures were significantly different (female, -1.83 versus -1.47; male, -1.86 versus -1.47; P < 0.05). CONCLUSION BMD measurements of the proximal femur were computed in routine contrast-enhanced MDCT and converted to DXA T-scores, which adequately differentiated patients with and without osteoporotic fractures.
Collapse
|
18
|
Transarterial Chemoembolization of Liver Metastases As Symptomatic Therapy of Lipase Hypersecretion Syndrome. J Clin Oncol 2012; 30:e209-12. [DOI: 10.1200/jco.2011.40.7627] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
|
19
|
Abstract
Pancreatic ductal adenocarcinoma (PDAC) is one of the five most lethal malignancies worldwide and survival has not improved substantially in the past 30 years. Desmoplasia (abundant fibrotic stroma) is a typical feature of PDAC in humans, and stromal activation commonly starts around precancerous lesions. It is becoming clear that this stromal tissue is not a bystander in disease progression. Cancer-stroma interactions effect tumorigenesis, angiogenesis, therapy resistance and possibly the metastatic spread of tumour cells. Therefore, targeting the tumour stroma, in combination with chemotherapy, is a promising new option for the treatment of PDAC. In this Review, we focus on four issues. First, how can stromal activity be used to detect early steps of pancreatic carcinogenesis? Second, what is the effect of perpetual pancreatic stellate cell activity on angiogenesis and tissue perfusion? Third, what are the (experimental) antifibrotic therapy options in PDAC? Fourth, what lessons can be learned from Langton's Ant (a simple mathematical model) regarding the unpredictability of genetically engineered mouse models?
Collapse
|
20
|
Coronary CT angiography in step-and-shoot technique with 256-slice CT: Impact of the field of view on image quality, craniocaudal coverage, and radiation exposure. Eur J Radiol 2012; 81:1562-8. [DOI: 10.1016/j.ejrad.2011.04.027] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2010] [Revised: 04/04/2011] [Accepted: 04/06/2011] [Indexed: 10/18/2022]
|
21
|
Converted lumbar BMD values derived from sagittal reformations of contrast-enhanced MDCT predict incidental osteoporotic vertebral fractures. Calcif Tissue Int 2012; 90:481-7. [PMID: 22484555 DOI: 10.1007/s00223-012-9596-3] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2012] [Accepted: 03/20/2012] [Indexed: 01/13/2023]
Abstract
We obtained baseline and follow-up bone mineral density (BMD) values of the lumbar spine from sagittal reformations of routine abdominal contrast-enhanced multidetector computed tomography (MDCT) using a reference phantom and assessed their performance in differentiating patients with no, existing, and incidental osteoporotic fractures of the spine. A MDCT-to-QCT (quantitative computed tomography) conversion equation for lumbar BMD measurements was developed by using 15 postmenopausal women (63 ± 12 years), who underwent standard lumbar QCT (L1-L3) and afterward routine abdominal contrast-enhanced MDCT. Sagittal reformations were used for corresponding lumbar BMD measurements. The MDCT-to-QCT conversion equation was applied to baseline and follow-up routine abdominal contrast-enhanced MDCT scans of 149 postmenopausal women (63 ± 10 years). Their vertebral fracture status (no, existing, or incidental osteoporotic fracture) was assessed in the sagittal reformations. A correlation coefficient of r = 0.914 (p < 0.001) was calculated for the BMD values of MDCT and standard QCT with the conversion equation BMD(QCT) = 0.695 × BMD(MDCT) - 7.9 mg/mL. Mean follow-up time of the 149 patients was 20 ± 12 months. Fifteen patients (10.1 %) had an existing osteoporotic vertebral fracture at baseline. Incidental osteoporotic vertebral fractures were diagnosed in 13 patients (8.7 %). Patients with existing and incidental fractures showed significantly (p < 0.05) lower converted BMD values (averaged over L1-L3) than patients without fracture at baseline and at follow-up. In this longitudinal study, BMD values of the lumbar spine derived from sagittal reformations of routine abdominal contrast-enhanced MDCT predicted incidental osteoporotic vertebral fractures.
Collapse
|
22
|
[Endoscopic and percutaneous intervention in the long-term treatment of benign biliary stenosis. A 71-year-old patient with cholestasis following radiotherapy]. Internist (Berl) 2012; 53:874-81. [PMID: 22527667 DOI: 10.1007/s00108-012-3053-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Benign biliary stenosis can have various causes and requires differentiation from disorders caused by malignant disease. Treatment of benign stenosis is often difficult and includes treatment modalities such as endoscopic, percutaneous or surgical interventions. Exact knowledge of the etiology and localization of the stenosis is essential when selecting the appropriate method of treatment. Here we present the case of a 71-year-old patient admitted to our hospital with cholangitis 13 years after undergoing radiotherapy of the renal bed due to hypernephroma of the right kidney. The patient was diagnosed with common bile duct stenosis due to the secondary effects of radiation, which is rarely reported in the literature. Our case covers a total treatment period of 15 years, enabling us to also discuss a viable sequence of treatment modalities in the treatment of benign bile duct stenosis.
Collapse
|
23
|
Comparison of 3'-deoxy-3'-[¹⁸F]fluorothymidine positron emission tomography (FLT PET) and FDG PET/CT for the detection and characterization of pancreatic tumours. Eur J Nucl Med Mol Imaging 2012; 39:846-51. [PMID: 22278320 DOI: 10.1007/s00259-012-2061-8] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2011] [Accepted: 01/02/2012] [Indexed: 12/14/2022]
Abstract
PURPOSE Despite recent advances in clinical imaging modalities, differentiation of pancreatic masses remains difficult. Here, we tested the diagnostic accuracy of molecular-based imaging including 3'-deoxy-3'-[(18)F]fluorothymidine (FLT) positron emission tomography (PET) and [(18)F]fluorodeoxyglucose (FDG) PET/CT in patients with suspected pancreatic masses scheduled to undergo surgery. METHODS A total of 46 patients with pancreatic tumours suspicious for malignancy and scheduled for resective surgery were recruited prospectively. In 41 patients, FLT PET and FDG PET/CT scans were performed. A diagnostic CT performed on a routine basis was available in 31 patients. FLT PET and FDG PET/CT emission images were acquired according to standard protocols. Tracer uptake in the tumour [FDG and FLT standardized uptake value (SUV)] was quantified by the region of interest (ROI) technique. For FDG PET/CT analysis, correct ROI placement was ensured via side-by-side reading of corresponding CT images. RESULTS Of 41 patients, 33 had malignancy, whereas 8 patients had benign disease. Visual analysis of FDG and FLT PET resulted in sensitivity values of 91% (30/33) and 70% (23/33), respectively. Corresponding specificities were 50% (4/8) for FDG PET and 75% (6/8) for FLT PET. In the subgroup of patients with contrast-enhanced CT (n = 31), sensitivities were 96% (PET/CT), 88% (CT alone), 92% (FDG PET) and 72% (FLT PET), respectively. Mean FLT uptake in all malignant tumours was 3.0 (range SUV(max) 1.1-6.5; mean FDG SUV(max) 7.9, range 3.3-17.8; p < 0.001). CONCLUSION For differentiation of pancreatic tumours, FDG PET and FDG PET/CT showed a higher sensitivity but lower specificity than FLT PET. Interestingly, visual analysis of FLT PET led to two false-positive findings by misinterpreting physiological bowel uptake as pathological FLT uptake in the pancreas. Due to the limited number of patients, the clinical value of adding FLT PET to the diagnostic workup of pancreatic tumours remains to be determined.
Collapse
|
24
|
Adenocarcinomas of the esophagogastric junction are more likely to respond to preoperative chemotherapy than distal gastric cancer. Ann Surg Oncol 2011; 19:2108-18. [PMID: 22130620 DOI: 10.1245/s10434-011-2147-8] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2011] [Indexed: 12/14/2022]
Abstract
BACKGROUND Preoperative chemotherapy has been shown to improve outcome of patients with adenocarcinoma of the esophagogastric junction (AEG) and gastric cancer (GC), and histopathologic response has been identified as an independent prognostic parameter in these patients. A recent meta-analysis has identified patients with AEG as benefiting more from preoperative chemotherapy than patients with GC. The aim of this retrospective analysis was to prove these findings in an experienced single-center large patient cohort because there are currently no recruiting prospective clinical trials. METHODS In a single center, 551 patients underwent preoperative platin-based chemotherapy followed by oncologic surgery for locally advanced AEG and GC. Pretherapeutic clinical parameters were correlated with histopathologic response to preoperative chemotherapy. RESULTS Histopathologic response (<10% of residual tumor) was found in 130 patients (24%) and was significantly correlated with overall survival (P<0.0001). Tumor localization at the esophagogastric junction (GE junction), lower baseline cT stage, and baseline cN0 stage were significantly associated with histopathologic response (P=0.034, P=0.015, and P=0.002, respectively). In subgroup analyses, the latter two predictive parameters were confirmed only for AEG (n=378) but not for other GC (n=173). AEG patients who were pretherapeutically staged as having cT3/4, cN0 disease (n=73) were identified as the subgroup with the highest rate of histopathologic response (48%). CONCLUSIONS AEG is more likely to respond to preoperative chemotherapy than GC, a finding that might help identify patients who would benefit from preoperative chemotherapy.
Collapse
|
25
|
Detection of intestinal bleeding with multi-detector row CT in an experimental setup. How many acquisitions are necessary? Eur Radiol 2011; 19:2862-9. [PMID: 19588146 DOI: 10.1007/s00330-009-1510-7] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2009] [Revised: 04/27/2009] [Accepted: 05/28/2009] [Indexed: 01/26/2023]
Abstract
The purpose of the study was to evaluate multi-detector computed tomography (MDCT) acquired in different acquisitions (unenhanced, and arterial and portal venous phase following intravenous contrast medium) for detection of intestinal bleeding using an experimental bowel model. The model consisted of an injector tube with a perforation placed in a 7-m-long small bowel of a pig. The bowel was filled with water/contrast medium solution of 30–40 HU and was incorporated in a phantom model. Intestinal bleeding in different locations and bleeding velocities varying from zero to 0.75 ml/min (0.05 ml/min increments) were simulated. Twenty-six datasets in simulated unenhanced, arterial and portal venous contrast phase using increasing bleeding velocities and ten negative controls were measured using 64-row MDCT. Two radiologists blinded to the experimental settings evaluated the datasets in a random order. The likelihood of intestinal bleeding was assessed using a 5-point scale with subsequent ROC analysis. The overall sensitivity for detecting bleeding was 0.44 for an arterial acquisition alone, 0.68 for a portal venous acquisition, 0.68 for the combination unenhanced/arterial, 0.72 for unenhanced/portal venous and 0.80 for arterial/portal. Bleeding velocities of above 0.25 ml/min were detected with a sensitivity of 0.59 for arterial, 0.88 for portal venous, 0.85 for unenhanced/arterial, 0.94 for unenhanced/portal venous and 0.97 for arterial/portal venous contrast phase protocols, respectively. The specificity was 1.00. MDCT provides the highest sensitivity and specificity in the detection of intestinal bleeding using arterial and portal venous acquisition in comparison to mono-phase protocols.
Collapse
|
26
|
Step and shoot coronary CT angiography using 256-slice CT: effect of heart rate and heart rate variability on image quality. Eur Radiol 2011; 21:2277-84. [PMID: 21710267 DOI: 10.1007/s00330-011-2185-4] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2011] [Revised: 04/21/2011] [Accepted: 05/09/2011] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To evaluate the effect of heart rate variability (HRV) and heart rate (HR) on intra-image "motion" and inter-image "stairstep" artefacts in step-and-shoot coronary CT angiography (CCTA) using a wide detector CT scanner. METHODS 66 patients underwent step-and-shoot CCTA using 256-slice CT. Patients were divided into two groups (Group 1: HR <65 bpm, Group 2 ≥65bpm). Motion artefacts were quantified using a 5-point-scale. Stairstep artefacts were defined by measurements of misalignment. Image noise, contrast-to-noise-ratio (CNR), signal-to-noise-ratio (SNR), and radiation dose were assessed. RESULTS Mean HR was 66 ± 16.7 bpm (range: 45-125 bpm) and mean HRV was 10.7 ± 17.5 bpm. A significant correlation between HR and stairstep artefacts (r = 0.46, p < 0.001) and motion artefacts (r = 0.63, p < 0.001) was found. Group 2 showed significantly increased step artefacts with a mean misalignment of 1.4 mm compared to 0.4 mm in Group 1 (p < 0.001). There was no significant effect of HRV on stairstep artefacts (r = 0.15, p = 0.416) and motion artefacts (r = 0.13, p = 0.311). No significant differences in image noise, CNR, SNR, and radiation dose were seen. CONCLUSIONS Unlike CCTA using narrow CT detectors, HRV has no significant effect on motion and stairstep artefacts using a wide CT detector with high z-coverage. However, a higher HR still increases stairstep and motion artefacts.
Collapse
|
27
|
[Preoperative CT angiography for planning free perforator flaps in breast reconstruction]. HANDCHIR MIKROCHIR P 2011; 43:88-94. [PMID: 21509699 DOI: 10.1055/s-0031-1275282] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
Abstract
Preoperative Doppler ultrasonography for planning free perforator flaps is widely established to identify preoperatively perforators. The method allows one to localise the penetrating point of the perforator through the abdominal fascia. By this means it is not possible to see the intramuscular course or the position of the perforator in relation to the inferior epigastric artery. Lately the technique of computed tomographic angiography provides an opportunity for visualising the course of perforator vessels in these tissues. This paper summarises our experience with the preoperative CT angiography in our breast centre. Since spring 2009 we have reconstructed the breasts of 44 female patients by using free flaps from the lower abdominal wall. 6 of these were bilateral. In a total number of 50 breast reconstructions we used 23 deep inferior epigastric perforator (DIEP) flaps and 27 muscle-sparing transverse rectus abdominis muscle (TRAM) flaps. In addition to the preoperative ultrasonography, a CT angiography of the lower abdomen was conducted in 29 patients. On average they showed at least 2 perforators on the left as well as right abdominal sides, which could be used as flap vessels based on their signal intensity. Based on their estimated microsurgical dissection complexity, the perforator vessels could be classified into 3 groups: 1) direct perforators of category A with short intramuscular course (39%), 2) perforators with long intramuscular course of category B (50%) and 3) "turn around" perforators of category C, which pass medially around the rectus abdominis (11%). The technique of CT angiography permits a reliable preoperative visualisation of perforators in their entire course and facilitates the selection of the supplying perforator as well as the intraoperative procedure for the surgeon. The suggested classification of perforators into 3 groups simplifies the preoperative assessment of the microsurgical dissection effort. Compared to the commonly used Doppler ultrasonography there are disadvantages like the additional cost factor and the radiation exposure. However, in our experience the more detailed planning increases the safety of flap raising and reduces surgery time, so that we consider CT angiography a positive tool to facilitate free perforator flaps.
Collapse
|
28
|
Herzfrequenz und Herzfrequenzvariabilität - was für eine Einfluss haben sie auf die Bildqualität bei der CT Koronarangiographie mit einem 256 Zeilen CT Scanner? ROFO-FORTSCHR RONTG 2011. [DOI: 10.1055/s-0031-1279574] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
29
|
„Chest pain“ CT Untersuchungen mit prospektiver EKG-Triggerung: erste Erfahrungen mit einem 256 Zeilen CT Scanner. ROFO-FORTSCHR RONTG 2011. [DOI: 10.1055/s-0031-1279570] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
30
|
Dosisreduktion mit einem iterativen Rekonstruktionsalgorythmus (iDose) in der MSCT. ROFO-FORTSCHR RONTG 2011. [DOI: 10.1055/s-0031-1279132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
31
|
BMD measurements of the spine derived from sagittal reformations of contrast-enhanced MDCT without dedicated software. Eur J Radiol 2010; 80:e140-5. [PMID: 20851544 DOI: 10.1016/j.ejrad.2010.08.034] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2010] [Revised: 08/17/2010] [Accepted: 08/26/2010] [Indexed: 11/28/2022]
Abstract
PURPOSE To assess QCT equivalent BMD of the lumbar spine in sagittal reformations of routine abdominal contrast-enhanced MDCT with simple PACS measurement tools and to apply this method to MDCT datasets for differentiating patients with and without osteoporotic vertebral fractures. MATERIALS AND METHODS Eight postmenopausal women (65±5 years) underwent standard QCT to assess BMD of L1-L3. Afterwards routine abdominal contrast-enhanced MDCT images of these women were obtained and apparent BMD of L1-L3 was measured using the sagittal reformations. The MDCT-to-QCT conversion equation for BMD was calculated with linear regression analysis. The conversion equation was applied to vertebral BMD datasets (L1-L3) of 75 postmenopausal women (66±4 years). Seventeen of the 75 patients had osteoporotic vertebral fractures. RESULTS BMD values of contrast-enhanced MDCT were on average 56 mg/ml higher than those of standard QCT. A correlation coefficient of r=0.94 (p<0.05) was calculated for the BMD values of MDCT and standard QCT with the conversion equation BMDQCT=0.69×BMDMDCT-11 mg/ml. Accordingly converted BMD values of patients with vertebral fractures were significantly lower than those of patients without vertebral fractures (69 mg/ml vs. 85 mg/ml; p<0.05). Using ROC analysis to differentiate patients with and without vertebral fractures, AUC=0.72 was obtained for converted BMD values (p<0.05). Short- and long-term reproducibility errors for BMD measurements in the sagittal reformations amounted 2.09% and 7.70%, respectively. CONCLUSION BMD measurements of the spine could be computed in sagittal reformations of routine abdominal contrast-enhanced MDCT with minimal technical and time effort. Using the conversion equation, the acquired BMD data could differentiate patients with and without osteoporotic vertebral fractures.
Collapse
|
32
|
|
33
|
CT Koronarangiographie mit prospektiver EKG-Triggerung an einem 256 Zeilen CT Scanner: Einfluss von Herzfrequenz und Herzfrequenzvariabilität auf die Bildqualität. ROFO-FORTSCHR RONTG 2010. [DOI: 10.1055/s-0030-1252627] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
34
|
[The "invisible" foreign body]. HNO 2009; 57:1133-5. [PMID: 19838653 DOI: 10.1007/s00106-009-1940-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
A 58-year-old female patient fell down a stairs carrying a plant pot. The bamboo stem penetrated the left lower lip and remained stuck in the throat. The patient pulled the bamboo stem out immediately. The lower lip was sutured and a tear in the mucous membrane in the tonsils was explored and cleansed. A foreign body could not be detected either clinically or by computed tomography (CT) of the neck. After 1 week a control CT of the neck was carried out because the patient complained of odynophagy and a putrid taste. An initially overlooked foreign body was now detected in the "lung window" and lay in an abscess cavity on the prevertebral surface. The foreign body was surgically removed with the patient under narcosis and there were no aftereffects.
Collapse
|
35
|
Sclerosing angiomatoid nodular transformation of the spleen presenting as a rapidly growing tumour in a patient with rectal cancer. BMJ Case Rep 2009; 2009:bcr11.2008.1191. [PMID: 21918654 DOI: 10.1136/bcr.11.2008.1191] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
A patient with rectal cancer developed a rapidly growing splenic mass 2 years after cancer treatment. Since a metastatic process could not be ruled out, splenectomy was performed, and the tumour emerged as a sclerosing angiomatoid nodular transformation (SANT) of the spleen. SANT is a rare, recently recognised, non-neoplastic vascular lesion of the spleen that radiologically may be difficult to distinguish from vascular splenic lesions such as splenic hamartoma, haemangioma or littoral cell angioma. However, morphologically and immunohistochemically it is separated from those tumours by its unique nodular angiomatoid proliferation pattern. SANT is considered to be a benign lesion. This case is reported because of its important clinical impact for the differential diagnosis of splenic masses. Data regarding growth rates of these lesions are scarce and a growth progression as in this case, that finally led to the indication for splenectomy due to lingering suspicion of malignancy, is novel.
Collapse
|
36
|
Evaluation of dual-phase multi-detector-row CT for detection of intestinal bleeding using an experimental bowel model. Eur Radiol 2008; 19:875-81. [PMID: 19018538 DOI: 10.1007/s00330-008-1205-5] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2008] [Revised: 09/15/2008] [Accepted: 09/21/2008] [Indexed: 01/09/2023]
Abstract
To evaluate dual-phase multi-detector-row computed tomography (MDCT) in the detection of intestinal bleeding using an experimental bowel model and varying bleeding velocities. The model consisted of a high pressure injector tube with a single perforation (1 mm) placed in 10-m-long small bowel of a pig. The bowel was filled with water/contrast solution of 30-40 HU and was incorporated in a phantom model containing vegetable oil to simulate mesenteric fat. Intestinal bleeding in different locations and bleeding velocities varying from zero to 1 ml/min (0.05 ml/min increments, constant bleeding duration of 20 s) was simulated. Nineteen complete datasets in arterial and portal-venous phase using increasing bleeding velocities, and seven negative controls were measured using a 64 MDCT (3-mm slice thickness, 1.5-mm reconstruction increment). Three radiologists blinded to the experimental settings evaluated the datasets in a random order. The likelihood for intestinal bleeding was assessed using a 5-point scale with subsequent ROC analysis. The sensitivity to detect bleeding was 0.44 for a bleeding velocity of 0.10-0.50 ml/min and 0.97 for 0.55-1.00 ml/min. The specificity was 1.00. The area under the curve was calculated to be 0.73, 0.88 and 0.89 for reader 1, 2 and 3, respectively. Dual-phase MDCT provides high sensitivity and specificity in the detection of intestinal bleeding with bleeding velocities of 0.5-1.0 ml/min. Therefore, MDCT should be considered as a primary diagnostic technique in the management of patients with suspected intestinal bleeding.
Collapse
|
37
|
WITHDRAWN: Immediate and mid-term results following hybrid procedures for the treatment of thoracoabdominal aneurysms (TAAA) and secondary expanding aortic dissections (SED). Ann Vasc Surg 2008:S0890-5096(08)00243-4. [PMID: 18783915 DOI: 10.1016/j.avsg.2008.06.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2007] [Revised: 06/23/2008] [Accepted: 06/23/2008] [Indexed: 11/27/2022]
|
38
|
Noninvasive therapy of incidental de novo renal cell carcinoma in a kidney allograft 12 years after transplantation: report of a case and review of literature. Transplant Proc 2008; 40:915-7. [PMID: 18555077 DOI: 10.1016/j.transproceed.2008.03.042] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
BACKGROUND Immunosuppressive therapy increases the incidence of posttransplantation cancer. Primary renal cell carcinoma (RCC) represents 4.6% of all cancers in transplant recipients. The treatment options for RCC in a renal allograft include radical nephrectomy or nephron-sparing surgery. We report the case of a patient who underwent percutaneous radiofrequency ablation (RFA) of a RCC in the grafted kidney. PATIENT AND METHODS Twelve years after undergoing heterotopic, allogenic kidney transplantation, a de novo lesion was diagnosed in the upper pole of the kidney graft in a 77-year-old patient during routine duplex ultrasonography. The magnetic resonance image showed a spherical lesion of 17 mm in diameter, which undoubtedly showed radiological signs of a RCC. After adequately informing the patient about alternative treatment strategies and the associated risks, we made an interdisciplinary decision for a percutaneous RFA of the lesion. RESULTS After the intervention, graft function remained unchanged and is still good at 6 months with no signs of local recurrence on follow-up MRI. A small coagulation defect at the site of the former lesion was the only morphological change. There was also no evidence of distant tumor spread. CONCLUSION Percutaneous RFA seems an acceptable, allograft-preserving treatment option associated with low morbidity and mortality for RCC in a renal allograft considering the significant risks associated with open partial nephrectomy in a kidney graft.
Collapse
|
39
|
Abstract
Malignant melanoma in the esophagus is a rare condition which has been described only occasionally in case reports or in larger series of patients with esophageal disease. We describe here the very rare case of a patient who presented initially with a 2-month history of dysphagia and weight loss which led to the endoscopic diagnosis of an unclear lesion in the distal esophagus. Biopsies were taken revealing positive immunohistochemical staining against HMB-45. As there were no signs of skin melanoma and there was an absence of pigmentation, a diagnosis of primary amelanotic malignant melanoma was made. Primary staging of the lesion was completed with computed tomography (CT), which revealed a locally advanced tumor with lymph node metastases at the lesser curvature of the stomach and celiac trunk. As there is still a lack of potential protocols for multimodal neoadjuvant treatment for this rare tumor entity, a palliative abdominothoracic esophagectomy with systemic lymphadenectomy and intrathoracic anastomosis was carried out. Due to an intraoperative R2 situation, clip marking was performed to allow postoperative radiotherapy. Two months postoperatively, the planning CT scan for radiotherapy revealed progression of the retroperitoneal tumor mass, which was enclosing the celiac trunk, renal vein, and superior mesenteric artery. Multiple new liver and lung metastases were also found. During the following weeks, the patient developed acute renal failure and was admitted for dialysis, and the planned radiotherapy was deferred. At the end of May 2007, 4 months after the primary diagnosis, the patient died due to acute renal failure.
Collapse
|
40
|
Early metabolic response evaluation by fluorine-18 fluorodeoxyglucose positron emission tomography allows in vivo testing of chemosensitivity in gastric cancer: long-term results of a prospective study. Clin Cancer Res 2008; 14:2012-8. [PMID: 18381939 DOI: 10.1158/1078-0432.ccr-07-0934] [Citation(s) in RCA: 110] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
PURPOSE We prospectively evaluated the predictive value of positron emission tomography using fluorine-18 fluorodeoxyglucose (FDG-PET) for in vivo testing of chemosensitivity in locally advanced gastric cancer using an a priori definition of metabolic response (a decrease of >35% of the standard uptake value). The goal of the study was the definition of biologically different groups of patients prior to or early during induction therapy, with special emphasis on FDG non-avid tumors. EXPERIMENTAL DESIGN Based on our data, which was published in 2003, at least 36 patients with metabolic response or FDG non-avid tumors had to be recruited for an analysis of the group of FDG non-avid tumors with sufficient statistical power. Seventy-one patients (32 metabolic nonresponders, 17 metabolic responders, and 22 patients with FDG non-avid tumors) underwent FDG-PET at baseline. In FDG-avid tumors, FDG-PET was repeated 14 days after the initiation of chemotherapy. RESULTS Metabolic responders (17 of 49) showed a high histopathologic response rate (69%) and a favorable prognosis (median survival not reached), whereas metabolic nonresponders (32 of 49) had a poor prognosis (median survival, 24.1 months) and showed a histopathologic response in 17%. The histopathologic response rate (24%) for FDG-PET non-avid patients showed no significant difference compared with FDG-avid nonresponders (P=0.72). Survival of FDG non-avid patients was 36.7 months (not significantly different from FDG-avid nonresponders, 24.1 months, P=0.46). CONCLUSION In locally advanced gastric cancer, three different metabolic groups exist. Response and survival was predicted by PET in FDG-avid tumors. Metabolic response assessment was not possible in FDG non-avid tumors; however, due to unfavorable outcome, therapy modification might also be considered in FDG non-avid tumors.
Collapse
|
41
|
CT-navigated real-time ultrasonography: evaluation of registration accuracy for clinical application / CT-navigierter Ultraschall: Evaluation der Registrierungsgenauigkeit für den klinischen Einsatz. ACTA ACUST UNITED AC 2008; 53:279-84. [DOI: 10.1515/bmt.2008.044] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
42
|
MSCT in arterieller und portalvenöser Kontrastphase zur Detektion intestinaler Blutungen. ROFO-FORTSCHR RONTG 2008. [DOI: 10.1055/s-2008-1073540] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
43
|
Hypoxia imaging with FAZA-PET and theoretical considerations with regard to dose painting for individualization of radiotherapy in patients with head and neck cancer. Int J Radiat Oncol Biol Phys 2007; 69:541-51. [PMID: 17869667 DOI: 10.1016/j.ijrobp.2007.05.079] [Citation(s) in RCA: 194] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2007] [Revised: 05/22/2007] [Accepted: 05/25/2007] [Indexed: 12/12/2022]
Abstract
PURPOSE To evaluate the role of hypoxia positron emission tomography (PET) using [18F]fluoroazomycin-arabinoside (FAZA) in head and neck cancer for radiation treatment planning using intensity-modulated radiotherapy and dose painting. METHODS AND MATERIALS Eighteen patients with advanced squamous cell head and neck cancer were included. Both FAZA-PET and axial CT were performed using mask fixation. The data were coregistered using software based on mutual information. Contours of tumor (primary gross tumor volume, GTV/CT-P) and lymph node metastases (GTV/CT-N) were outlined manually, and FAZA standardized uptake values (SUVs) were calculated automatically. The hypoxic subvolume (GTV/PET-FAZA) having at least 50% more FAZA uptake than background (mean SUV) neck muscle tissue was contoured automatically within GTV/CT-P (GTV/PET-FAZA-P) and GTV/CT-N (GTV/PET-FAZA-N). RESULTS The median GTV/PET-FAZA-P was 4.6 mL, representing 10.8% (range, 0.7-52%) of the GTV/CT-P. The GTV/PET-FAZA-P failed to correlate significantly with the GTV/CT-P (p = 0.06). The median GTV/PET-FAZA-N was 4.1 mL, representing 8.3% (range, 2.2-51.3%) of the GTV/CT-N. It was significantly correlated with the GTV/PET-N (p = 0.006). The GTV/PET-FAZA-P was located in a single confluent area in 11 of 18 patients (61%) and was diffusely dispersed in the whole GTV/CT-P in 4 of 18 patients (22%), whereas no hypoxic areas were identified in 3 of 18 patients (17%). The GTV/PET-FAZA-N was outlined as a single confluent region in 7 of 18 patients (39%), in multiple diffuse hypoxic regions in 4 of 18 patients (22%), and was not delineated in 7 of 18 patients (39%). CONCLUSION This study demonstrates that FAZA-PET imaging could be used for a hypoxia-directed intensity-modulated radiotherapy approach in head and neck cancer.
Collapse
|
44
|
[Focal nodular liver lesions associated with a congenital portocaval shunt in an adult woman]. Radiologe 2007; 47:163-4, 166. [PMID: 17891851 DOI: 10.1007/s00117-005-1265-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
The Abernethy malformation is a rare anomaly with partial or complete congenital absence of the portal vein and subsequent development of extrahepatic portocaval shunts. Diagnosis is usually made in childhood following the finding of liver neoplasms combined with slightly increased liver enzymes. There is a female predominance. Further findings are malformations of the heart, skeletal system and kidneys. Short-term follow-up of the liver lesions is recommended. Progressive disease can be treated by partial liver resection or transplantation. Diagnosis of the Abernethy malformation is based on various imaging modalities. We report the MRI and MRA findings of an Abernethy malformation in a 35-year-old woman with multiple liver cell adenomas and review the 32 previously published cases.
Collapse
|
45
|
Rectal Cancer: MR Imaging before Neoadjuvant Chemotherapy and Radiation Therapy for Prediction of Tumor-Free Circumferential Resection Margins and Long-term Survival1. Radiology 2007; 243:744-51. [PMID: 17463134 DOI: 10.1148/radiol.2433060421] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To retrospectively evaluate the prognostic importance of involvement of the circumferential resection margin predicted by using magnetic resonance (MR) imaging before neoadjuvant treatment in patients with rectal cancer. MATERIALS AND METHODS The local institutional review board approved the retrospective analysis of the data and waived informed consent. Sixty-eight patients (52 men, 16 women; mean age +/- standard deviation, 58.9 years +/- 9.4) with cT3 NX M0 tumors were included. T2-weighted MR images were analyzed in consensus by two radiologists with respect to the shortest distance between the outermost parts of the tumor to the adjacent mesorectal fascia (as the potential circumferential resection margin in total mesorectal excision). Histopathologic and follow-up data were available for all patients (mean follow-up time, 54 months; range, 31-77 months). To compare local recurrence and survival rates, the population was divided into three groups categorized according to the minimum distance of the tumor to the mesorectal fascia (group 1, <or=1 mm; group 2, >1 to 5 mm; group 3, >5 mm). Univariate Cox and multivariate proportional hazard regression models were used to test the prognostic importance of clinical, histopathologic regression, and histopathologic tumor parameters. RESULTS MR imaging led to accurate prediction of a histologically involved circumferential resection margin (sensitivity, 100%; specificity, 88%). The rates for local recurrence (group 1, 33%; group 2, 5%; group 3, 6%; P<.02) and 5-year overall survival (group 1, 39%; group 2, 70%; group 3, 90%; P<.001) differed significantly among the predefined groups. The distance to the mesorectal fascia was an independent prognostic parameter in multivariate analysis (P<.001), and histopathologic response to treatment provided no additional information. CONCLUSION Prediction of the tumor-free circumferential resection margin assessed with MR imaging before initiation of neoadjuvant chemotherapy and radiation therapy proved to be a prognostic factor in rectal cancer.
Collapse
|
46
|
Quadruple-phase MDCT of the liver in patients with suspected hepatocellular carcinoma: effect of contrast material flow rate. AJR Am J Roentgenol 2006; 186:1571-9. [PMID: 16714645 DOI: 10.2214/ajr.05.1226] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The purposes of this study were to evaluate the effect of contrast material flow rate (3 mL/sec vs 5 mL/sec) on the detection and visualization of hepatocellular carcinoma (HCC) with MDCT and the safety profile of iodixanol at different injection rates. SUBJECTS AND METHODS In a prospective, randomized multicenter trial, 97 patients (83 men and 14 women, with a mean age of 64 years) suspected of having HCC underwent quadruple-phase (double arterial, portal venous, delayed phase) 4-16-MDCT. Patients were randomized to receive iodixanol, 320 mg I/mL (1.5 mL/kg body weight), at a flow rate of 3 mL/sec (48 patients) or 5 mL/sec (49 patients). Qualitative (lesion detection, image quality) and quantitative (liver and aortic enhancement, tumor-liver contrast) analyses and safety assessment were performed. RESULTS Overall, 145 HCCs were detected in the 5 mL/sec group and 100 HCCs in the 3 mL/sec group (p < 0.05). More lesions equal to or less than 1 cm were detected at 5 mL/sec (33 vs 16 lesions). The late arterial phase showed significantly more lesions than the early, arterial phase (133 vs 100 and 96 vs 67 lesions, respectively, p < 0.0001). Hyperattenuating HCCs were better visualized in the late arterial phase at 5 mL/sec (excellent visualization: 54% vs 27%). Using a flow of 5 mL/sec did not increase the rate of patient discomfort or contrast media-related adverse events. Most discomfort in both groups was of mild intensity and there was no severe discomfort. CONCLUSION For detection of HCC with MDCT, a higher flow rate of 5 mL/sec is recommended. Visualization of hyperattenuating HCC is improved with no greater discomfort or adverse events.
Collapse
|
47
|
Abstract
OBJECTIVE The objective of our study was to compare the diagnostic performance of 16-MDCT with that of MRI in the characterization of kidney lesions. SUBJECTS AND METHODS Twenty-eight patients with kidney lesions detected with sonography and requiring further evaluation were examined. MDCT was performed in the unenhanced, arterial, and portal venous phases. MRI was performed at 1.5 T with T2- and T1-weighted and dynamic gadolinium-enhanced sequences. Consensus reading was done by two radiologists. Image quality was rated on a four-point scale. Classification of lesions as surgical or nonsurgical was done with five levels of confidence, and it was required that a definite diagnosis be assigned to each lesion. The 1997 TNM classification was used for staging. Statistical analysis was done by receiver operating characteristic analysis or paired Student's t test. Histologic or follow-up findings at least 12 months after the primary diagnosis served as the standard of reference. RESULTS The image quality of MDCT (mean grade, 2.79 on a 0-3 scale) was superior to that of MRI (1.93; p < 0.01). The area under the curve for differentiating surgical from nonsurgical lesions was 0.979 for MDCT and 0.957 for MRI with resulting sensitivity and specificity values of 92.3% and 96.3% for MDCT and 92.3% and 91.3% for MRI. Sensitivity and specificity for definite classification of the lesions were 93.8% and 68.4% for MDCT and 93.8% and 71.4% for MRI. CONCLUSION Both MDCT and MRI are excellent for differentiating surgical from nonsurgical kidney lesions. Both methods have low specificity for the differentiation of benign from malignant lesions.
Collapse
|
48
|
Hepatocellular Carcinoma Associated with Hereditary Hemochromatosis Occurring in Non-Cirrhotic Liver. ZEITSCHRIFT FUR GASTROENTEROLOGIE 2006; 44:39-42. [PMID: 16397838 DOI: 10.1055/s-2005-858567] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
The occurrence of primary hepatocellular carcinoma (HCC) in patients with hereditary hemochromatosis (HH) is well known. Thereby, the development of liver cirrhosis seems to be a prerequisite. Whether or not a hepatic iron overload in the context of hereditary hemochromatosis is an independent risk factor for HCC remains unclear. To date there are only a few reports about HCC arising in non-cirrhotic livers in the presence of HH. We report the case of a 64-year-old man who presented to our outpatient clinic with HCC. Liver cirrhosis could be excluded. Detailed exploration of the patient's history revealed that he had been treated by venesection for about 10 years up to 15 years ago. Subsequent investigations showed an elevated serum ferritin and transferrin saturation. The diagnosis of HH was confirmed by genetic testing, with homozygosity for the Cys282Tyr mutation. The patient received palliative chemotherapy and finally died 15 months after initial diagnosis of HCC.
Collapse
|
49
|
Detection of osteoporotic vertebral fractures using multidetector CT. Osteoporos Int 2006; 17:608-15. [PMID: 16437195 DOI: 10.1007/s00198-005-0023-8] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/04/2005] [Accepted: 09/29/2005] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Goals were to compare the performance of lateral radiographs and sagittal reformations (SR) of axial computed tomography (CT) datasets in identification of osteoporotic vertebral fractures and to assess for optimal slice thickness in axial CT datasets needed for reliable classification of these fractures. METHODS Sixty-five vertebrae were harvested from 21 human cadaver spines and examined with a 64-row multidetector CT scanner. Axial images were acquired with a slice thickness of 0.6, 1, 2, 3 and 5 mm and SR were obtained using these datasets. In addition, specimens were radiographed in antero-posterior and lateral orientation. Vertebrae visualized in the different image datasets were separately graded by four radiologists according to the spinal fracture index (SFI) classification. Fracture status determined in a consensus reading of interactive reformations of the 0.6-mm CT dataset in all three dimensions served as a standard of reference in combination with pathological examinations. RESULTS The average agreement for the 0.6-mm SR obtained between each radiologist and standard of reference for the grading of the fractures was very good (kappa=0.81). It was good for the 1-, 2- and 3-mm SR (kappa=0.70, 0.69 and 0.64), but only moderate for the radiographs (kappa=0.52), and fair for the 5-mm SR (kappa=0.33). When focusing only on detection of fractures, independent of the grading, all kappa values improved by about 0.15, resulting in excellent values for the 0.6-mm through 3-mm SR (0.95<kappa<0.79) and good values for the radiographs (kappa=0.72). Ninety-five percent of the fractures could be identified using the 1-mm SR, but 18% of the fractures were missed on the radiographs. CONCLUSIONS Sagittal CT reformations could more accurately assess vertebral fractures than standard radiographs. But for reliable detection of these fractures, SR derived from axial images with a slice thickness of 3 mm or less are required. The thinnest available axial slice thickness performed best in fracture grading.
Collapse
|
50
|
Detektion osteoporotischer Wirbelkörperfrakturen mittels Mehrzeilen CT. ROFO-FORTSCHR RONTG 2006. [DOI: 10.1055/s-2006-940742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|