1
|
Ruhswurm I, Scholz U, Zehetmayer M, Hanselmayer G, Vass C, Skorpik C. Astigmatism correction with a foldable toric intraocular lens in cataract patients. J Cataract Refract Surg 2000; 26:1022-7. [PMID: 10946194 DOI: 10.1016/s0886-3350(00)00317-5] [Citation(s) in RCA: 157] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To determine the efficacy and rotational stability of a toric posterior chamber silicone intraocular lens (IOL) to correct preoperative astigmatism in cataract patients. SETTING Department of Ophthalmology, University Hospital of Vienna, Vienna Austria. METHODS Between 1993 and 1998, foldable toric single-piece plate-haptic silicone IOLs were implanted in 37 eyes (30 patients). The cylindrical IOL power was 2.00 diopters (D) (n = 29), 3.50 D (n = 7), or 4.00 D (n = 1). Phacoemulsification was performed through a scleral or a corneal sutureless self-sealing incision. Outcomes of Snellen visual acuity (without, with spherical, and with best correction), refractive and keratometric astigmatism, and IOL rotation after early postoperative (mean 15.9 days +/- 10.1 [SD]) and long-term (mean 20.3 +/- 16.6 months) follow-ups were evaluated. RESULTS At last follow-up, 31 eyes (83.8%) had a spherically corrected and 34 (91.9%) a best corrected visual acuity of 0.5 (20/40) or better. Mean preoperative refractive and keratometric astigmatism was 2.68 and 2.70 D, respectively. At the last postoperative follow-up, mean refractive astigmatism was reduced to 0.84 D; keratometric astigmatism was 2.30 D. In 7 eyes (18.9%), the IOL axis was rotated a maximum of 25 degrees. In all 37 eyes, the axis of the toric IOL remained within 30 degrees of rotation. CONCLUSIONS Early postoperative and long-term follow-ups showed effective and stable correction of astigmatism after implantation of a foldable toric posterior chamber silicone IOL.
Collapse
|
Comparative Study |
25 |
157 |
2
|
Radner W, Zehetmayer M, Aufreiter R, Mallinger R. Interlacing and cross-angle distribution of collagen lamellae in the human cornea. Cornea 1998; 17:537-43. [PMID: 9756449 DOI: 10.1097/00003226-199809000-00012] [Citation(s) in RCA: 100] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE The interlacing and cross angles between the collagen lamellae within the human corneal stroma were studied by means of scanning electron microscopy (SEM). METHODS For SEM, cells and noncollagenous extracellular matrix were removed with 10% sodium hydroxide. Transmission electron microscopy (TEM) preparations were performed according to standard procedures. The interlacing of lamellae was studied within the limbal, paracentral, and central regions of five different layers. The cross angles between the longitudinal axes of adjacent lamellae were measured. The distribution of these angles within defined layers and regions was compared. Special attention was paid to the interlacing of the lamellae. RESULTS Lamellae split in an anteroposterior direction as well as horizontally into branches and are interlaced by crossing the fissures between the branches. Smaller lamellae cross through clefts of neighboring lamellae. The cross angles show a high variability of 1 degree - 90 degrees. With the exception of the limbal region of the layer adjacent to Descemet's membrane, the distribution of cross angles is similar. A frequent occurrence of cross angles <30 degrees (68%) in this limbal layer can be explained by a pseudocircular orientation (ligamentum circulare corneae) of the lamellae. CONCLUSION The present study shows that the three-dimensional organization of the collagen lamellae is characterized by a greater extent of lamellar interlacing than has been assumed until now.
Collapse
|
|
27 |
100 |
3
|
Zehetmayer M, Kitz K, Menapace R, Ertl A, Heinzl H, Ruhswurm I, Georgopoulos M, Dieckmann K, Pötter R. Local tumor control and morbidity after one to three fractions of stereotactic external beam irradiation for uveal melanoma. Radiother Oncol 2000; 55:135-44. [PMID: 10799725 DOI: 10.1016/s0167-8140(00)00164-x] [Citation(s) in RCA: 82] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND AND PURPOSE To evaluate prospectively local tumor control and morbidity after 1-3 fractions of stereotactic external beam irradiation (SEBI) in patients with uveal melanoma, unsuitable for ruthenium-106 brachytherapy or local resection. MATERIAL AND METHODS This phase I/II study includes 62 selected patients with uveal melanoma. The mean initial tumor height was 7.8+/-2.8 mm. With the Leskell gamma knife SEBI, 41 patients (66%) were irradiated with two equal fractions of 35, 30 or 25 Gy/fraction, 14 patients (22%) were treated with three fractions of 15 Gy each, and seven patients (11%) with small tumor volumes below 400 mm(3) were treated with one fraction of 45 Gy. The mean total dose was 54+/-8 Gy. The minimal follow-up period was 12 months, and the median follow-up was 28.3 months. Data on radiation-induced side-effects were analyzed with the Cox proportional hazards model for possible risk factors. RESULTS Local tumor control was achieved in 98% and tumor height reduction in 97%. The mean relative tumor volume reductions were 44, 60 and 72% after 12, 24 and 36 months, respectively. Seven patients developed metastases (11%). Secondary enucleation was performed in eight eyes (13%). Morbidity was significant in tumors exceeding 8 mm in initial height; it was comparable and acceptable in those smaller. In the stepwise multiple Cox model, tumor localization, height and volume, planning target volume (PTV), total dose and patient age were identified as the strongest risk factors for radiation-induced lens opacities, secondary glaucoma, uveitis, eyelash loss and exudative retinal detachment. In this model, the high-dose volume irradiated with more than 10 Gy/fraction was the strongest risk factor for radiation-induced uveitis. CONCLUSIONS Stereotactic external photon beam irradiation and a total dose of 45-70 Gy delivered in one to three fractions are highly effective at achieving local tumor control in uveal melanoma. Further clinical studies using smaller fraction doses, and consequent smaller high-dose volumes, are justified to optimize dose and fractionation. Fractionated stereotactic irradiation has a challenging potential as an eye-preserving treatment in uveal melanoma.
Collapse
|
Clinical Trial |
25 |
82 |
4
|
Radner W, Zehetmayer M, Skorpik C, Mallinger R. Altered organization of collagen in the apex of keratoconus corneas. Ophthalmic Res 2000; 30:327-32. [PMID: 9704337 DOI: 10.1159/000055492] [Citation(s) in RCA: 71] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
PURPOSE In 15 keratoconus corneas, the three-dimensional arrangement of collagen lamellae was investigated by means of scanning electron microscopy. METHODS Keratoconus corneas without visible scars were obtained during perforating keratoplasty. The noncollagenous matrix of the stroma was removed with sodium hydroxide. Descemet's membrane was removed mechanically and deeper layers of the stroma were exposed by cutting the tissue tangentially to the corneal surface with an ultramicrotome. The apical and the para-apical regions of keratoconus were compared the central regions of normal corneas. RESULTS In the apical regions of 11 out of the 15 keratoconus corneas (73%), the arrangement of the collagen lamellae differs from those of the para-apical regions and normal corneas. Their collagen fibrils from uniform layers and no delimited collagen lamellae can be differentiated. Interlacing between adjacent layers in extremely decreased or even absent. In the para-apical region of keratoconus corneas the three-dimensional arrangement of collagen lamellae does not differ from that in normal corneas. CONCLUSION Stromal thinning and conical ectasia in the apex of keratoconus corneas alters the organization of collagen. This will certainly affect the biomechanical properties of the cornea and further lead to a progression of keratoconus irrespective of its primary pathogenesis.
Collapse
|
|
25 |
71 |
5
|
Zehetmayer M, Radax U, Skorpik C, Menapace R, Schemper M, Weghaupt H, Scholz U. Topical versus peribulbar anesthesia in clear corneal cataract surgery. J Cataract Refract Surg 1996; 22:480-4. [PMID: 8733854 DOI: 10.1016/s0886-3350(96)80046-0] [Citation(s) in RCA: 70] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
PURPOSE To evaluate the efficacy of topical anesthesia as an alternative to peribulbar anesthesia in clear corneal cataract surgery. SETTING Department of Ophthalmology, University of Vienna, Austria. METHODS In this prospective, double-blind clinical trial, 36 patients had bilateral cataract surgeries performed from 1 to 3 months apart. Half of the patients had topical anesthesia for the first surgery and peribulbar anesthesia for the second surgery. The other half had peribulbar first and then topical. All surgery was done using a temporal clear corneal approach and bimanual phacoemulsification followed by in-the-bag intraocular lens implantation. Subjective pain was assessed using a visual analog scale of no pain (0%) to worst pain imaginable (100%) and intraoperative motility using a rank scale of adverse motility (-5) to ideal patient cooperation (+5). RESULTS Subjective pain was comparable whether topical or peribulbar anesthesia was used (mean 10.75 versus 10.97%; P > .6). Patient cooperation (motility) was significantly better when topical anesthesia was used (+2.16 versus +1.11; P = .03). There were no significant differences in complications. A peribulbar block was given in addition to the topical anesthesia in two cases. CONCLUSIONS Topical anesthesia is a safe, effective alternative to peribulbar anesthesia in clear corneal cataract surgery.
Collapse
|
Clinical Trial |
29 |
70 |
6
|
Dunavoelgyi R, Dieckmann K, Gleiss A, Sacu S, Kircher K, Georgopoulos M, Georg D, Zehetmayer M, Poetter R. Local tumor control, visual acuity, and survival after hypofractionated stereotactic photon radiotherapy of choroidal melanoma in 212 patients treated between 1997 and 2007. Int J Radiat Oncol Biol Phys 2010; 81:199-205. [PMID: 20675066 DOI: 10.1016/j.ijrobp.2010.04.035] [Citation(s) in RCA: 68] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2010] [Revised: 04/21/2010] [Accepted: 04/27/2010] [Indexed: 12/01/2022]
Abstract
PURPOSE To evaluate long-term local tumor control, visual acuity, and survival after hypofractionated linear accelerator-based stereotactic photon radiotherapy in patients with choroidal melanoma. METHODS AND MATERIALS Between 1997 and 2007, 212 patients with choroidal melanoma unsuitable for ruthenium-106 brachytherapy or local resection were treated stereotactically at a linear accelerator with 6-MV photon beams at the Medical University of Vienna in five fractions over 7 days. Twenty-four patients received a total dose of 70 Gy (five fractions of 14 Gy), 158 a total dose of 60 Gy (five fractions of 12 Gy) and 30 patients a total dose of 50 Gy (five fractions of 10 Gy) applied on the 80% isodose. Ophthalmologic examinations were performed at baseline and every 3 months in the first 2 years, every 6 months until 5 years, and once a year thereafter until 10 years after radiotherapy. Assessment of visual acuity, routine ophthalmologic examinations, and measurement of tumor base dimension and height using standardized A-scan and B-scan echography were done at each visit. Funduscopy and fluorescein angiography were done when necessary to document tumor response. RESULTS Median tumor height and volume decreased from 4.8 mm and 270.7 mm3 at baseline to 2.6 mm and 86.6 mm3 at the last individual follow-up, respectively (p<0.001, p<0.001). Median visual acuity decreased from 0.55 at baseline to hand motion at the last individual follow-up (p<0.001). Local tumor control was 95.9% after 5 years and 92.6% after 10 years. Thirty-two patients developed metastatic disease, and 22 of these patients died during the follow-up period. CONCLUSION Hypofractionated stereotactic photon radiotherapy with 70 to 50 Gy delivered in five fractions in 7 days is sufficient to achieve excellent local tumor control in patients with malignant melanoma of the choroid. Disease outcome and vision are comparable to those achieved with proton beam radiotherapy. Decreasing the total dose below 60 Gy seems to be possible.
Collapse
|
Journal Article |
15 |
68 |
7
|
Dieckmann K, Georg D, Zehetmayer M, Bogner J, Georgopoulos M, Pötter R. LINAC based stereotactic radiotherapy of uveal melanoma: 4 years clinical experience. Radiother Oncol 2003; 67:199-206. [PMID: 12812851 DOI: 10.1016/s0167-8140(02)00345-6] [Citation(s) in RCA: 65] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To study local tumor control and radiogenic side effects after fractionated LINAC based stereotactic radiotherapy for selected uveal melanoma. PATIENTS AND METHODS Between June 1997 and March 2001, 90 patients suffering from uveal melanoma were treated at a LINAC with 6 MV. The head was immobilized with a modified stereotactic frame system (BrainLAB). For stabilization of the eye position a light source was integrated into the mask system in front of the healthy or the diseased eye. A mini-video camera was used for on-line eye movement control. Tumors included in the study were either located unfavorably with respect to macula and optical disc (<3 mm distance) or presented with a thickness >7 mm. Median tumor volume was 305+/-234 mm3 (range 70-1430 mm3), and mean tumor height was 5.4+/-2.3 mm (range 2.7-15.9 mm). Total doses of 70 (single dose 14 Gy @ 80% isodose) or 60 Gy (single dose 12 Gy @ 80% isodose) were applied in five fractions within 10 days. The first fractionation results in total dose (TD) (2 Gy) of 175 Gy for tumor and 238 Gy for normal tissue, corresponding values for the second fractionation schedule are 135 and 180 Gy, respectively. RESULTS After a median follow-up of 20 months (range 1-48 months) local control was achieved in 98% (n=88). The mean relative tumor reductions were 24, 27, and 37% after 12, 24 and 36 months. Three patients (3.3%) developed metastases. Secondary enucleation was performed in seven patients (7.7%). Long term side effects were retinopathy (25.5%), cataract (18.9%), optic neuropathy (20%), and secondary neovascular glaucoma (8.8%). CONCLUSION Fractionated LINAC based stereotactic photon beam therapy in conjunction with a dedicated eye movement control system is a highly effective method to treat unfavorably located uveal melanoma. Total doses of 60 Gy (single dose 12 Gy) are considered to be sufficient to achieve good local tumor control.
Collapse
|
|
22 |
65 |
8
|
Pfleger T, Skorpik C, Menapace R, Scholz U, Weghaupt H, Zehetmayer M. Long-term course of induced astigmatism after clear corneal incision cataract surgery. J Cataract Refract Surg 1996; 22:72-7. [PMID: 8656367 DOI: 10.1016/s0886-3350(96)80273-2] [Citation(s) in RCA: 59] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
PURPOSE To determine whether a small clear corneal temporal incision produces less surgically induced astigmatism than a larger incision. METHODS One hundred three consecutive cases of postoperative astigmatism after clear corneal incision cataract surgery were studied for a minimum of 1 year. Only self-sealing incisions from the temporal side were made as follows: 3.2 mm (Group A); 4.0 mm (Group B); 5.2 mm (Group C). We considered the amount and axes of the keratometric readings at different times as well as their course over time. Induced astigmatism was calculated using three methods. Axial changes were also analyzed. RESULTS Immediately after the surgery, there was a small, surgically induced, with-the-rule astigmatic shift in all groups, which in most cases decreased to near preoperative levels with time. One year postoperatively. mean induced astigmatism was 0.09 diopter (D) in Group A, 0.26 D in Group B, and 0.54 D in Group C. Most cases had minimal axial changes. In Group A, 86% had an axial change of fewer than 30 degrees; in Group B, 76%; and Group C, 73%. CONCLUSIONS The smallest incision group had the least surgically induced astigmatism and axial change. All incision groups remained stable and had satisfactory clinical results.
Collapse
|
Comparative Study |
29 |
59 |
9
|
Dieckmann K, Bogner J, Georg D, Zehetmayer M, Kren G, Pötter R. A linac-based stereotactic irradiation technique of uveal melanoma. Radiother Oncol 2001; 61:49-56. [PMID: 11578728 DOI: 10.1016/s0167-8140(01)00413-3] [Citation(s) in RCA: 42] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
PURPOSE To describe a stereotactic irradiation technique for uveal melanomas performed at a linac, based on a non-invasive eye fixation and eye monitoring system. METHODS For eye immobilization a light source system is integrated in a standard stereotactic mask system in front of the healthy eye: During treatment preparation (computed tomography/magnetic resonance imaging) as well as for treatment delivery, patients are instructed to gaze at the fixation light source. A mini-video camera monitors the pupil center position of the diseased eye. For treatment planning and beam delivery standard stereotactic radiotherapy equipment is used. If the pupil center deviation from a predefined 'zero-position' exceeds 1 mm (for more than 2 s), treatment delivery is interrupted. Between 1996 and 1999 60 patients with uveal melanomas, where (i) tumor height exceeded 7 mm, or (ii) tumor height was more than 3 mm, and the central tumor distance to the optic disc and/or the macula was less than 3 mm, have been treated. A total dose of 60 or 70 Gy has been given in 5 fractions within 10 days. RESULTS The repositioning accuracy in the mask system is 0.47+/-0.36 mm in rostral-occipital direction, 0.75+/-0.52 mm laterally, and 1.12+/-0.96 mm in vertical direction. An eye movement analysis performed for 23 patients shows a pupil center deviation from the 'zero' position<1 mm in 91% of all cases investigated. In a theoretical analysis, pupil center deviations are correlated with GTV 'movements'. For a pupil center deviation of 1 mm (rotation of the globe of 5 degrees ) the GTV is still encompassed by the 80% isodose in 94%. CONCLUSION For treatments of uveal melanomas, linac-based stereotactic radiotherapy combined with a non-invasive eye immobilization and monitoring system represents a feasible, accurate and reproducible method. Besides considerable technical requirements, the complexity of the treatment technique demands an interdisciplinary team continuously dedicated to this task.
Collapse
|
|
24 |
42 |
10
|
Georg D, Dieckmann K, Bogner J, Zehetmayer M, Pötter R. Impact of a micromultileaf collimator on stereotactic radiotherapy of uveal melanoma. Int J Radiat Oncol Biol Phys 2003; 55:881-91. [PMID: 12605965 DOI: 10.1016/s0360-3016(02)04119-6] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
PURPOSE To evaluate the impact of a micro multileaf collimator (mMLC) on Linac-based stereotactic radiotherapy (SRT) of uveal melanoma by comparing circular arc with static conformal, dynamic arc, and intensity-modulated SRT. MATERIALS AND METHODS Forty uveal melanoma patients were selected from approximately 100 patients treated with SRT since 1996. For each patient, four treatment plans (BrainSCAN XL, V5.0) were made: conventional arc, static conformal, dynamic arc plan, and intensity-modulated radiotherapy (IMRT). The goal of treatment planning was to fully encompass the planning target volume (PTV) by the 80% isodose while minimizing doses to the optic nerve and lens. The following parameters were evaluated: target conformity; target homogeneity; ratio of the target volume and 50% isodose volume; normal tissue receiving doses >/=80%, >/=50%, and >/=20%; central nervous system volume irradiated to >/=20%; optical nerve volume irradiated >/=50%, D(max) of the lens; lens volume receiving >/=20%; and monitor units. RESULTS PTVs ranged from 0.68 to 4.90 cm(3) (mean 1.97 +/- 0.97 cm(3)). The average reduction of the prescription isodose volume was 1-1.5 cm(3) for conformal (range 2.6-0.3 cm(3)), dynamic arc (range 2.5-0.3 cm(3)), and IMRT plans (range 3.9-0.1 cm(3)), compared with conventional arc therapy. Central nervous system volumes irradiated to doses >/=20% were smallest for conventional or dynamic arc treatments. Average target dose homogeneity values were 1.74 +/- 0.50 for arc, 1.27 +/- 0.02 for static mMLC, 1.26 +/- 0.01 for dynamic arc, and 1.15 +/- 0.03 for IMRT plans. IMRT helped to reduce doses to the lens but did not provide an advantage for optical nerve sparing. When applying IMRT, the monitor units increased by approximately one-third compared with static mMLC-based SRT. CONCLUSIONS Conformal mMLC and dynamic arc SRT are the treatment options of choice for Linac-based SRT of uveal melanoma. They present dosimetric advantages, while being highly efficient in treatment planning and delivery.
Collapse
|
Evaluation Study |
22 |
40 |
11
|
Ertl A, Berg A, Zehetmayer M, Frigo P. High-resolution dose profile studies based on MR imaging with polymer BANG(TM) gels in stereotactic radiation techniques. Magn Reson Imaging 2000; 18:343-9. [PMID: 10745144 DOI: 10.1016/s0730-725x(99)00131-9] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
High-resolution dose profiles produced by the Leksell Gamma Knife were obtained in BANG(TM) polymer gel, using a 3 T whole-body scanner upgraded by a magnetic resonance microscopy unit. The gel was contained in 22.3 mm diameter flasks that were inserted into a solid, tissue-equivalent head phantom irradiated by fields of by 8 and 14 mm collimators. Dose profiles were obtained from a linear dose-response curve (R(2) vs. Dose). Excellent agreement was obtained when the gel data were compared to film dosimetry and calculated data.
Collapse
|
|
25 |
40 |
12
|
Chabert S, Velikay-Parel M, Zehetmayer M. Influence of uveal melanoma therapy on patients' quality of life: a psychological study. ACTA ACUST UNITED AC 2004; 82:25-31. [PMID: 14982042 DOI: 10.1046/j.1600-0420.2003.0210.x] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE The objective of this study ws to describe the quality of life of 98 patients treated with brachytherapy or stereotactic external beam irradiation, either with the Leksell Gamma Knife or a 6-MV LINAC. METHODS The EORTC QLQ-C30 and the EORTC QLQ-OPT37 psychological questionnaires and the HADS-D scale were used. Two visual analogue scales (VASs) were applied to compare overall quality of life before and after treatment. RESULTS The results revealed no significant differences in quality of life (p=0.215) among treatments with different methods of radiotherapy. Comparison of quality of life before and after therapy did, however, indicate a decrease in quality of following radiotherapy. The average binocular visual acuity (VA) was 0.8 (range 0.3-1). Complication arising from the treatment included a reduction in VA in the affected eye, keratitis, cataract, scleral and corneal necrosis, radiation retinopathy, radiation optic neuropathy, retinal detachment and glaucoma. CONCLUSIONS Due to the diagnosis revealed and the subsequent radiotherapy, patients with uveal melanoma experienced a reduced quality of life. However, compared to patients with other types of cancer, they seemed to feel relatively well and showed fewer signs of deterioration.
Collapse
|
Journal Article |
21 |
32 |
13
|
Bogner J, Petersch B, Georg D, Dieckmann K, Zehetmayer M, Pötter R. A noninvasive eye fixation and computer-aided eye monitoring system for linear accelerator-based stereotactic radiotherapy of uveal melanoma. Int J Radiat Oncol Biol Phys 2003; 56:1128-36. [PMID: 12829151 DOI: 10.1016/s0360-3016(03)00280-3] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
PURPOSE To introduce a noninvasive eye fixation and computer-aided eye monitoring system for linear accelerator-based stereotactic radiotherapy for uveal melanoma. METHODS AND MATERIALS At the Department of Radiotherapy and Radiobiology, University of Vienna, stereotactic radiotherapy is offered to patients with uveal melanoma considered unsuitable for (106)Ru brachytherapy or local resection. For the present feasibility study, 8 patients were carefully selected according to their ability to fixate a small light source with the diseased eye and whether they had a rather small head to meet the limited geometric space available. A polymethyl methacrylate tube was attached to a stereotactic mask system in craniocaudal orientation supporting a 45 degrees mirror, which was placed in front of the diseased eye. At the other end of the tube, the patient was given a small fixation light, and a small camera was positioned beneath, which was shielded for use during MRI. A computer interface calculated and visualized the spatial difference of the actual and a given reference pupil position, which was defined before CT scanning, during the MRI sequences, and during treatment delivery at the linear accelerator. RESULTS The described system can be attached to a conventional stereotactic mask system with minor modifications. Because of the large distance between the eye and the fixation light, the optical fixation system was well tolerated by all patients, and a stable position of the eye was obtained. The camera system can be used during CT and MRI without interference. Absorption of the 6-MV photon beam by the mirror and the polymethyl methacrylate tube was negligible. The computer interface designed to determine the pupil position uses an image-processing algorithm that correlates a template of the reference image with the actual image of the eye. Provided sufficient illumination of the pupil, the correlation function showed a pronounced minimum at the reference position. The precision of the algorithm was tested by phantom measurements. For a given 1 mm or 2 mm displacement, the interface reported a mean shift of 0.96 +/- 0.18 mm or 2.07 +/- 0.11 mm, respectively. CONCLUSION The results of this study demonstrated the feasibility of a new optical fixation system for linear accelerator-based stereotaxis. The artifact-free application of the camera system during image acquisition and irradiation and the use of the computer interface, which automatically monitored eye movements with submillimeter precision, provided large improvements compared with existing techniques. Given well-defined interruption criteria and accelerated image processing, the described system has a high potential to perform automatically gated treatment beam delivery in the near future.
Collapse
|
|
22 |
29 |
14
|
Sacu S, Ségur-Eltz N, Stenng K, Zehetmayer M. Ocular firework injuries at New Year's eve. Ophthalmologica 2002; 216:55-9. [PMID: 11901290 DOI: 10.1159/000048298] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
PURPOSE To prospectively study mechanisms and injury characteristics of ocular firework burns. METHODS A prospective analysis of all patients with firework injuries attending the Department of Ophthalmology, University of Vienna, between 1994 and 2001. We looked for classes of fireworks and mechanisms of injuries. The number of diagnoses was established and their severity classified. RESULTS During this period (8 years) we identified 116 eyes of 102 patients. 67/102 (66%) of all injuries were caused by class II and III fireworks. Patients ranged between 4 and 83 years. Ocular injuries occurred more frequently in males (69, 68%) and affected the right eye in 53 patients (52.5%). Ocular firework injuries to minors (under the age of 18 years) occurred in 48 (49%). The most common types of injury were skin and corneal erosions and abrasions (32/116, 28%). 11/116 eyes (10%) had severe injuries. 8 of 11 severe injuries (72%) occurred in minors (<18 years). 2 patients (1.7%) developed permanent blindness. In 32/116 patients (28%), the ocular trauma resulted in visual impairment, mainly due to corneal scars or retinal pathologies. In all patients, the severity index was 1.4 +/- 0.8. In minors the severity index was 1.6 +/- 1.0, in adults 1.2 +/- 0.5 (p = 0.013). CONCLUSION Injuries in minors were significantly more severe than those in adults. Possible preventive measures include legislation, education of minors and eye protection.
Collapse
|
|
23 |
28 |
15
|
Ruhswurm I, Zehetmayer M, Dejaco C, Wolf B, Karner-Hanusch J. Ophthalmic and genetic screening in pedigrees with familial adenomatous polyposis. Am J Ophthalmol 1998; 125:680-6. [PMID: 9625552 DOI: 10.1016/s0002-9394(98)00005-1] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
PURPOSE To study the possible association between ophthalmic findings, genetic status, and clinical course of the disease in Austrian pedigrees with familial adenomatous polyposis (FAP). METHODS Thirty-nine members of 16 consecutive FAP families with 20 affected patients and 19 relatives with a 50% a priori risk to develop the disease were examined ophthalmologically. The intestinal status of all persons was established by colonoscopy. Direct or indirect molecular genetic analysis, or both, was possible in eight of the 16 FAP families. RESULTS Congenital hypertrophy of the retinal pigment epithelium (CHRPE) was discovered in 15 (75%) of the 20 persons affected by familial adenomatous polyposis. Five (25%) of the patients with an established FAP were CHRPE-negative. Four of the 19 at-risk individuals were CHRPE-positive. According to DNA analysis, five of the 19 at-risk relatives had a high risk to develop a manifest disease. The ophthalmoscopic tests were in complete agreement with the molecular risk estimation. Furthermore, the combined results of endoscopy and ophthalmoscopy suggested a relationship between a positive CHRPE status and the severity of FAP. CONCLUSIONS Ophthalmic examinations facilitate predictive diagnosis in FAP patients and first-degree relatives, permitting a noninvasive, highly reliable risk assessment. When present, CHRPE lesions are a reliable clinical marker for FAP in CHRPE-positive families. In CHRPE negative families, negative ophthalmic examinations are of no predictive value. The CHRPE status can add information about the location of the genetic mutation. The combination of an ophthalmic examination with DNA analysis and endoscopy improves the risk assessment of FAP carriers.
Collapse
|
|
27 |
27 |
16
|
Ruhswurm I, Scholz U, Pfleger T, Zehetmayer M, Hanselmayer G, Skorpik C. Three-year clinical outcome after penetrating keratoplasty for keratoconus with the guided trephine system. Am J Ophthalmol 1999; 127:666-73. [PMID: 10372876 DOI: 10.1016/s0002-9394(99)00036-7] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
PURPOSE To determine the long-term clinical outcome after keratoplasty with the guided trephine system in keratoconus eyes. METHODS In a prospective study, all consecutive cases of penetrating keratoplasty had trephination performed with the guided trephine system, with which both donor and recipient cornea are trephined from the epithelial side with a same-sized blade. For wound closure, a double running antitorque suture technique with 10-0 nylon was used. Uncorrected and best-corrected Snellen visual acuity, subjective refraction, and astigmatism by keratometry were evaluated after final suture removal, 2 and 3 years postoperatively. RESULTS In the 31 patients (31 eyes) enrolled, mean best-corrected visual acuity improved from 0.72 +/- 0.16 (20/30) after final suture removal to 0.88 +/- 0.15 (20/25) 3 years postoperatively (P < .001). The mean spherical equivalent increased from -0.86 +/- 2.10 diopters after final suture removal to -2.35 +/- 2.65 diopters 3 years postoperatively (P < .001). Mean keratometric astigmatism decreased from 4.68 +/- 1.76 diopters after final suture removal to 3.57 +/- 1.37 diopters 3 years postoperatively (P = .001). Furthermore, an increase in mean keratometric levels with time (P = .01) was observed and associated with myopic shift (r(s) = -.46, P = .008). CONCLUSION With the guided trephine system, we attained favorable visual results, with prolonged improvement of visual acuity during the entire follow-up period. Our data show low and decreasing degrees of corneal astigmatism over time. During the follow-up period, a myopic shift was found after final suture removal. Nevertheless, this technique of performing same-sized grafts reduces postoperative residual myopia.
Collapse
|
|
26 |
27 |
17
|
Zehetmayer M, Menapace R, Kulnig W. Combined local excision and brachytherapy with ruthenium-106 in the treatment of epibulbar malignancies. Ophthalmologica 1993; 207:133-9. [PMID: 8278179 DOI: 10.1159/000310419] [Citation(s) in RCA: 26] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Two patients with epibulbar malignancies were treated by local excision and brachytherapy with ruthenium-106. One patient showed a large melanoma on the epibulbar conjunctiva, the other patient suffered from a recurrent squamous cell carcinoma at the limbus. After excision of the tumor including lamellar sclerectomy and keratectomy, a ruthenium-106 plaque was sutured to the sclera, and a total dose of 290 and 320 Gy, respectively, was delivered to the tumor bed. No severe radiogenic complications were observed except for a rarefaction of the sclera in the treatment area and a slow cataract increase. After a follow-up period of 50 and 22 months, respectively, both patients do not show any recurrence or metastatic disease.
Collapse
|
Case Reports |
32 |
26 |
18
|
Dunavoelgyi R, Zehetmayer M, Simader C, Schmidt-Erfurth U. Rapid improvement of radiation-induced neovascular glaucoma and exudative retinal detachment after a single intravitreal ranibizumab injection. Clin Exp Ophthalmol 2007; 35:878-80. [PMID: 18173426 DOI: 10.1111/j.1442-9071.2007.01632.x] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
|
18 |
25 |
19
|
Georgopoulos M, Zehetmayer M, Ruhswurm I, Toma-Bstaendig S, Ségur-Eltz N, Sacu S, Menapace R. Tumour regression of uveal melanoma after ruthenium-106 brachytherapy or stereotactic radiotherapy with gamma knife or linear accelerator. Ophthalmologica 2003; 217:315-9. [PMID: 12913319 DOI: 10.1159/000071345] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2002] [Accepted: 02/27/2003] [Indexed: 11/19/2022]
Abstract
PURPOSE This study assesses differences in relative tumour regression and internal acoustic reflectivity after 3 methods of radiotherapy for uveal melanoma: (1) brachytherapy with ruthenium-106 radioactive plaques (RU), (2) fractionated high-dose gamma knife stereotactic irradiation in 2-3 fractions (GK) or (3) fractionated linear-accelerator-based stereotactic teletherapy in 5 fractions (Linac). METHODS Ultrasound measurements of tumour thickness and internal reflectivity were performed with standardised A scan pre-operatively and 3, 6, 9, 12, 18, 24 and 36 months postoperatively. Of 211 patients included in the study, 111 had a complete 3-year follow-up (RU: 41, GK: 37, Linac: 33). Differences in tumour thickness and internal reflectivity were assessed with analysis of variance, and post hoc multiple comparisons were calculated with Tukey's honestly significant difference test. RESULTS Local tumour control was excellent with all 3 methods (>93%). At 36 months, relative tumour height reduction was 69, 50 and 30% after RU, GK and Linac, respectively. In all 3 treatment groups, internal reflectivity increased from about 30% initially to 60-70% 3 years after treatment. CONCLUSION Brachytherapy with ruthenium-106 plaques results in a faster tumour regression as compared to teletherapy with gamma knife or Linac. Internal reflectivity increases comparably in all 3 groups. Besides tumour growth arrest, increasing internal reflectivity is considered as an important factor indicating successful treatment.
Collapse
|
Comparative Study |
22 |
25 |
20
|
Zehetmayer M, Menapace R, Kitz K, Ertl A. Suction attachment for stereotactic radiosurgery of intraocular malignancies. Ophthalmologica 1994; 208:119-21. [PMID: 8065694 DOI: 10.1159/000310467] [Citation(s) in RCA: 24] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
We designed a suction attachment for the radiosurgical treatment of intraocular malignancies with the Leksell gamma unit (Gamma Knife). Our device consists of a circular suction chamber and an adjustable unit to be fixed to the Leksell stereotactic head frame. All components are made of plastic materials in order to avoid artifacts in CT or MRT imaging. A permanent suction of 600-800 mbar is provided by a standard vacuum pump, powered by a portable battery. Suction times up to 40 min were well tolerated in all cases. We successfully used this device, performing 17 radiosurgical treatments in 8 patients with large or extra-large uveal melanomas and one patient suffering from a choroidal metastasis.
Collapse
|
|
31 |
24 |
21
|
Ertl A, Zehetmayer M, Schöggl A, Kitz K, Koschuch R, Stadtmann H, Kindl P. Shuttle dose at the Vienna Leksell Gamma Knife. Phys Med Biol 1998; 43:1567-78. [PMID: 9651026 DOI: 10.1088/0031-9155/43/6/015] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
The aim of this study was to determine the shuttle dose for all collimator helmets (4, 8, 14 and 18 mm) of the Gamma Knife, model B, in Vienna, Austria. The additional dose accumulated during the transport of the patient in and out of the treatment position should be considered in the dose planning procedure of multicentre treatment regimens and in fractionated stereotactic Gamma Knife radiotherapy. The GafChromic film study was basically used to determine the shuttle dose of all four collimator helmets. In addition, measurements with an ionization chamber (18 and 14 mm collimator--and, for the 18 mm collimator helmet, TLD dosimetry--were performed in order to confirm the GafChromic film data. The shuttle dose ranged between 99.6 and 183.5 mGy, depending mainly on the size of the collimator and the irradiated isocentres at the half-life activity of Co-60 in a brand new Gamma unit. Our film-generated data were in good correlation with the dose levels obtained with the ionization chamber and the TLD dosimetry, showing a dose difference of less than 0.8%. Since it was possible to verify the shuttle dose even for the 4 and 8 mm collimator helmets, we consider it a non-negligible factor and would advocate the inclusion of the shuttle dose in radiosurgical dose planning.
Collapse
|
Comparative Study |
27 |
21 |
22
|
Zehetmayer M, Menapace R, Kitz K, Ertl A, Strenn K, Ruhswurm I. Stereotactic irradiation of uveal melanoma with the Leksell gamma unit. FRONTIERS OF RADIATION THERAPY AND ONCOLOGY 1997; 30:47-55. [PMID: 9205884 DOI: 10.1159/000425687] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
|
28 |
20 |
23
|
Sacu S, Ségur-Eltz N, Horvat R, Lukas JR, Zehetmayer M. Intumescent cataract after topical mitomycin-C for conjunctival malignant melanoma. Am J Ophthalmol 2003; 136:375-7. [PMID: 12888073 DOI: 10.1016/s0002-9394(03)00207-1] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
PURPOSE To present the clinical and histologic findings of a patient in whom intumescent cataract developed after successful topical mitomycin-C (MMC) chemotherapy for conjunctival melanoma originating from primary acquired conjunctival melanosis (PAM) with atypia. DESIGN Observational case report; follow-up at 30 months. METHODS In a patient with PAM and subsequent conjunctival melanoma that was successfully treated with topical MMC chemotherapy an intumescent cataract developed after two cycles of 0.04% MMC, each for 1 month. RESULTS After MMC chemotherapy pigmentation of the acquired melanosis vanished almost completely. Histopathology of the check-up specimen revealed local tumor control. Six weeks after the completion of the second cycle, an intumescent cataract developed. Cataract surgery was performed uneventfully. The patient was followed up for 30 months. CONCLUSIONS In selected cases, topical MMC chemotherapy is effective for treating conjunctival melanoma. Although severe complications are rare and usually transient, development of cataract may be observed. A prospective study should be initiated.
Collapse
|
Case Reports |
22 |
19 |
24
|
Zehetmayer M, Dieckmann K, Kren G, Kitz K, Ruhswurm I, Georgopoulos M, Pötter R. Fractionated stereotactic radiotherapy with linear accelerator for uveal melanoma--preliminary Vienna results. Strahlenther Onkol 1999; 175 Suppl 2:74-5. [PMID: 10394403 DOI: 10.1007/bf03038894] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
PURPOSE To study local tumor control and radiogenic side-effects after fractionated stereotactic radiotherapy for uveal melanoma. PATIENTS AND METHODS Between June 1997 and February 1998, 21 patients suffering from uveal melanomas have been treated with stereotactic 6 MeV LINAC (Saturne 43, General Electric, France) in conjunction with a stereotactic frame system (BrainLAB, Germany). Immobilization of the eye was ensured with an optical fixation system which was proven reliable. During radiotherapy, movements of the irradiated eye were controlled on a monitor and documented by video recording. All patients co-operated very well with the optical fixation system. In 1164 measurements, the median value of horizontal deviation of the diseased eye during treatment was 0.3 mm (range: 0 to 1.3 mm). Median vertical deviation was 0.2 mm (range: 0 to 1.2 mm). For all patients, mean tumor prominence before treatment was 6.0 +/- 2.2 mm. In 20 patients, the total dose of 70 Gy (at 80%) was delivered in 5 fractions within 10 days. In one patient with a ciliary body tumor, the total dose of 70 Gy was divided into 7 fractions for better sparing of the anterior eye segment. RESULTS After a follow-up of at least 6 months, local tumor control was seen in all eyes. Mean tumor thickness reduction after 3, 6 and 9 months was 7%, 13% and 31%, respectively. Up to now, only mild subacute side-effects located in the anterior eye segment have been noticed. CONCLUSION Optical fixation of the eye allows high precision stereotactic radiotherapy with small safety margins. Fractionated stereotactic radiotherapy and 70 Gy total dose delivered in 5 fractions seems to be appropriate for local tumor control in uveal melanoma. Further long-term studies with extended number of patients will be necessary to conclude on the use of linac-based fractionated stereotactic radiotherapy for uveal melanoma.
Collapse
|
|
26 |
18 |
25
|
Zehetmayer M, Rainer G, Turnheim K, Skorpik C, Menapace R. Topical anesthesia with pH-adjusted versus standard lidocaine 4% for clear corneal cataract surgery. J Cataract Refract Surg 1997; 23:1390-3. [PMID: 9423913 DOI: 10.1016/s0886-3350(97)80120-4] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
PURPOSE To evaluate and compare the efficacy of a sodium-bicarbonate-adjusted preparation of lidocaine 4% (pH = 7.2) and standard lidocaine (pH = 5.2) for topical anesthesia in clear corneal cataract surgery. SETTING Department of Ophthalmology, University of Vienna, Austria. METHODS In a prospective, randomized, double-blind clinical trial, clear corneal cataract surgery was performed under topical anesthesia in 44 eyes of 34 patients. In 22 eyes, pH-adjusted lidocaine 4% was administered; in the other 22, standard lidocaine 4%. Aqueous and serum concentrations of lidocaine were measured by high-performance liquid chromatography and ultraviolet detection. Subjective pain was assessed using a visual analog scale of no pain (0%) to worst imaginable pain (100%). On the first postoperative day, visual acuity, intraocular pressure, and corneal staining with fluorescein were examined. RESULTS In the pH-adjusted lidocaine group, significantly higher lidocaine concentrations were found in the aqueous humor (15.06 microg/mL +/- 8.2 [SD] versus 4.75 +/- 3.5 microg/mL; P < .0001). In all samples (n = 8), serum lidocaine concentrations were below a minimum detectable level of 0.02 microg/mL. Subjective pain ratings were similar in the pH-adjusted and standard lidocaine groups (mean 9.73 +/- 10.4% and 10.0 +/- 15.4%, respectively). There was no significant between-group difference in intraoperative and postoperative outcomes. CONCLUSIONS In this study, pH-adjusted lidocaine 4% was a safe, effective topical anesthetic for clear corneal surgery and had minimal local and systemic toxicity. Administration of pH-adjusted lidocaine 4% resulted in significantly higher aqueous humor lidocaine concentrations than administration of standard lidocaine 4%.
Collapse
|
Clinical Trial |
28 |
18 |