1
|
Fast-sampling fast-ion D-alpha measurement using multi-anode photomultiplier tube in large helical device. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2023; 94:103505. [PMID: 37819204 DOI: 10.1063/5.0159175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Accepted: 09/20/2023] [Indexed: 10/13/2023]
Abstract
A fast-sampling fast-ion D-alpha (F-FIDA) measurement has been developed in the large helical device in order to investigate fast ion dynamics associated with helically trapped fast-ion-driven Magnetohydrodynamic (MHD) bursts. F-FIDA consists of a multi-anode photomultiplier tube (PMT) and achieves a sampling rate of 10 kHz. During the deuterium experiment campaign in 2022, F-FIDA measured the spectrum of perpendicular fast ions, using perpendicular lines of sight. We compared F-FIDA with conventional FIDA, using an electron multiplying charge coupled device, and confirmed that the time-averaged images were generally consistent between the two. The statistical properties of the temporal evolution associated with MHD bursts were analyzed using a conditional sampling technique. The results showed that the PMT signal varied in different spatial and wavelength channels. Although the signal-to-noise ratio was poor and there was room for improvement, it could provide useful information for studies on the phase-space dynamics of fast ions.
Collapse
|
2
|
Optimization of a fast deuterium diagnostic method based on visible energetic 3He spectroscopy for high electron density plasmas. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2023; 94:063502. [PMID: 37862490 DOI: 10.1063/5.0110088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Accepted: 05/22/2023] [Indexed: 10/22/2023]
Abstract
Fast ions play a crucial role in plasma heating, and their behavior in the plasma must be accurately understood. A diagnostics method based on charge exchange emission from the n = 4 - 3 transition (λ0 = 468.6 nm) of energetic 3He produced by the deuteron-deuteron reaction has been proposed as a for fast deuterons with energies in the order of MeV. The proposed method has the following advantages: No beam emission interferes with the spectra, the direction of the measuring line of sight, and the injection angle of the diagnostic beam can be freely determined. In previous studies, due to competing bremsstrahlung, it was expected that the proposed method will not be practical in the case of high electron density operation. This paper makes the proposed method available for measurement even at high electron densities by optimizing the measurement line of sight direction and the diagnostic beam incidence angle. This allows an electron density five times larger than the range of applications shown in previous studies. This result will contribute to measure of DT alpha in ITER.
Collapse
|
3
|
Feasibility study of neutral beam injection in Thailand Tokamak-1. FUSION ENGINEERING AND DESIGN 2023. [DOI: 10.1016/j.fusengdes.2023.113419] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
4
|
A gamma ray spectrometer with Compton suppression on the HL-2A tokamak. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2022; 93:123509. [PMID: 36586945 DOI: 10.1063/5.0117186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Accepted: 11/15/2022] [Indexed: 06/17/2023]
Abstract
A new broad-energy, high-resolution gamma ray spectrometer (GRS) with Compton suppression function has been developed recently in the HL-2A tokamak to obtain the gamma ray information in the energy range of 0.1-10 MeV. This is the first time to develop an anti-Compton GRS for a magnetic confinement fusion device. The anticoincidence detector consists of a large-volume high purity germanium (HPGe) crystal (Φ63 × 63 mm2) as the primary detector and eight trapezoidal bismuth germinate (BGO) scintillators (trapezoid crystal with 30 mm thickness) as the secondary detector. The anti-coincidence data processing is implemented by a digital-based data acquisition system with fast digitization and software signal processing technology. Using radioisotope gamma ray sources and Monte Carlo N-Particle code, the energy and efficiency of the spectrometer have been calibrated and quantitatively tested. The Compton continuum suppression factor reaches 4.2, and the energy resolution (Full Width at Half Maximum) of the 1.332 MeV full energy peak for 60Co is 2.1 keV. Measurements of gamma ray spectra with Compton suppression using the spectrometer have been successfully performed during HL-2A discharges with different conditions. The performance of the spectrometer and the first experimental results are presented in this paper.
Collapse
|
5
|
Contribution of dental health in cardiovascular secondary prevention. Eur Heart J 2022. [DOI: 10.1093/eurheartj/ehac544.2319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Backgrounds
Previous studies have suggested that periodontitis is associated with cardiovascular disease (CVD), partly through exaggerated systematic inflammation through pathogens breaking into the bloodstream and their metabolic products. However, the clinical evidence in the cardiovascular secondary prevention is limited. In addition, there is a paucity of data about the contribution of comprehensively assessed dental health, including dental caries or teeth loss, to CVD incidence. Consequently, current ESC guideline for CVD prevention just briefly refers the contribution of dental health [1].
Objective
To investigate the associations between teeth loss, periodontitis, and dental caries and incident major adverse cardiovascular events (MACE) in patients with existing CVD.
Methods
Patients with known CVD who were admitted to the Department of Cardiology between May 2012 and August 2015 were prospectively, consecutively enrolled. Patients underwent comprehensive dental examinations, including counts of lost teeth, dental caries, and periodontal measurements of clinical attachment loss (CAL), periodontal probing pocket depth (PPD), and bleeding on probing (BOP) by trained periodontists during the hospital stay. We assessed the associations between these dental measures and MACE, defined as a composite of cardiac death, acute myocardial infarction, stroke, and hospital re-admission for worsened congestive heart failure, using multivariate COX proportional hazard models and restricted mean survival time (RMST) analyses. P-values were adjusted by Bonferroni methods.
Results
Among 888 patients included for the present analyses, the mean age was 63.9 (SD: 13.1) years and there were 242 (27.3%) women. During a median follow-up of 4.6 (IQR: 1.4, 6.7) years, incident MACE was confirmed in 142 patients. In multivariate COX proportional hazard models, one more tooth loss was associated with 3 (95% CI: 1, 5) % higher hazard of MACE (adjusted p=0.020). Kaplan-Meier curves showing survival from MACE according to the quartiles of teeth loss were described in Figure 1. Compared with patients with 0 to ≤4 lost teeth, periods free from MACE (95% CI) by 5-years of follow-up were on average shorter by 0.17 (−0.04, 0.37) years, 0.26 (0.04, 0.49) years, and 0.59 (0.34, 0.85) years in patients with 5 to ≤7, 8 to ≤13, and >13 lost teeth, respectively. The RMST differences with varied cutoff years were shown in Figure 2. There were no significant associations between the number of dental caries, CAL, PPD, and BOP and MACE incidence.
Conclusion
In hospitalized patients due to existing cardiovascular diseases, total number of lost teeth was associated with incident MACE. Given that teeth loss is an ultimate consequence of periodontitis or dental caries, the present findings imply that efforts to prevent losing teeth by maintaining dental health would be effective measures for cardiovascular secondary prevention.
Funding Acknowledgement
Type of funding sources: None.
Collapse
|
6
|
Initial operation of perpendicular line-of-sight compact neutron emission spectrometer in the large helical device. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2022; 93:093504. [PMID: 36182517 DOI: 10.1063/5.0100494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Accepted: 08/10/2022] [Indexed: 06/16/2023]
Abstract
The perpendicular line-of-sight compact neutron emission spectrometer (perpendicular CNES) was newly installed to understand the helically trapped fast-ion behavior through deuterium-deuterium (D-D) neutron energy spectrum measurement in the Large Helical Device (LHD). The energy calibration of the EJ-301 liquid scintillation detector system for perpendicular CNES was performed on an accelerator-based D-D neutron source. We installed two EJ-301 liquid scintillation detectors, which view the LHD plasma vertically from the lower side through the multichannel collimator. The D-D neutron energy spectrum was measured in a deuterium perpendicular-neutral-beam-heated deuterium plasma. By the derivative unfolding technique, it was found that the D-D neutron energy spectrum had a double-humped shape with peaks at ∼2.33 and ∼2.65 MeV. D-D neutron energy spectrum was calculated based on the fast ion distribution function using guiding center orbit-following models considering the detector's energy resolution. The calculated peak energies in the D-D neutron energy spectrum almost match the experiment. In addition, a feasibility study toward the measurement of the energy distribution of ion-cyclotron-range-of-frequency-wave-accelerated beam ions was performed.
Collapse
|
7
|
Evaluation of Alpha Particle Emission Rate Due to the p- 11B Fusion Reaction in the Large Helical Device. FUSION SCIENCE AND TECHNOLOGY 2022. [DOI: 10.1080/15361055.2021.1973294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
8
|
Fast deuteron diagnostics using visible light spectra of 3He produced by deuteron-deuteron reaction in deuterium plasmas. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:053524. [PMID: 34243281 DOI: 10.1063/5.0034683] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Accepted: 04/23/2021] [Indexed: 06/13/2023]
Abstract
The fast deuteron (non-Maxwellian component) diagnostic method, which is based on the higher resolution optical spectroscopic measurement, has been developed as a powerful tool. Owing to a decrease in the D-H charge-exchange cross section, the diagnostic ability of conventional optical diagnostic methods should be improved for ∼MeV energy deuterons. Because the 3He-H charge-exchange cross section is much larger than that of D-H in the ∼MeV energy range, the visible light (VIS) spectrum of 3He produced by the dueteron-dueteron (DD) reaction may be a useful tool. Although the density of 3He is small because it is produced via the DD reaction, improvement of the emissivity of the VIS spectrum of 3He can be expected by using a high-energy beam. We evaluate the VIS spectrum of 3He for the cases when a fast deuteron tail is formed and not formed in the ITER-like beam injected deuterium plasma. Even when the beam energy is in the MeV energy range, a large change appears in the half width at half maximum of the VIS spectrum. The emissivity of the VIS spectrum of 3He and the emissivity of bremsstrahlung are compared, and the measurable VIS spectrum is obtained. It is shown that the VIS spectrum of 3He is a useful tool for the MeV beam deuteron tail diagnostics.
Collapse
|
9
|
Investigation of the distribution of remaining tritium in divertor in LHD. NUCLEAR MATERIALS AND ENERGY 2021. [DOI: 10.1016/j.nme.2020.100884] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
10
|
A Hard X-Ray Pinhole Camera System for Fast Electron Bremsstrahlung Measurements in the HL-2A Tokamak. FUSION SCIENCE AND TECHNOLOGY 2021. [DOI: 10.1080/15361055.2020.1829457] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
11
|
Cardiac function at diagnosis is important prognostic factor in patients with cardiac sarcoidosis -from Japanese nationwide questionnaire survey-. Eur Heart J 2020. [DOI: 10.1093/ehjci/ehaa946.2130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Background
Sarcoidosis is a systemic non-caseating granulomatous disease of unknown etiology. Cardiac involvement (cardiac sarcoidosis, CS) has been reported to be an important prognostic factor in this disease because of heart failure and/or ventricular arrhythmia, and corticosteroid therapy is usually prescribed to prevent cardiac events. However, little is known about the relationship of cardiac function and concomitant corticosteroid therapy on later cardiac events in CS.
Objective
We evaluated the relationship between prognosis and left ventricular ejection fraction (LVEF) at the time of diagnosis in CS patients from the Japanese nationwide questionnaire survey.
Methods
Total of 757 Japanese patients from 57 hospitals who diagnosed CS were examined. Patients who unsatisfied the criteria of the Japanese new guidelines, or who underwent cardiac transplantations were excluded, and 420 patients (287 females, mean age 60±13 years old, median follow-up periods 1864 days [interquartile range: 845–3159 days]) were analyzed. The relationship of adverse events (all-cause death, cardiovascular death, and appropriate ICD [Implantable Cardioverter Defibrillator] discharge) and LVEF (with corticosteroid 84%) (low LVEF: LVEF≤35% n=98 [with corticosteroid in 78%], moderate LVEF: LVEF 35–50% n=104 [with corticosteroid in 93%], normal LVEF: 50≤LVEF n=218 [with corticosteroid in 83%]) were evaluated respectively.
Results
89 CS patients developed all-cause death (n=50), cardiovascular death (n=30) or appropriate ICD discharge (n=48). The frequency of corticosteroid therapy was not different in the each LVEF group, but Kaplan-Meier analysis revealed that all-cause death, cardiovascular death, and all cardiovascular adverse events were more observed in lower LVEF group (log-rank p<0.0001). Furthermore, multivariate Cox hazard analysis revealed that LVEF was a most important independent prognostic factor in CS.
Conclusion
This Japanese nationwide questionnaire survey data showed that initial LVEF was an independent and strong prognostic predictor in CS, therefore primary prevention would be needed even after starting corticosteroid in patients with decreased cardiac function.
Funding Acknowledgement
Type of funding source: None
Collapse
|
12
|
Long time clinical course of cardiac sarcoidosis with corticosteroid therapy -from Japanese nationwide questionnaire survey-. Eur Heart J 2020. [DOI: 10.1093/ehjci/ehaa946.2109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Abstract
Background
Sarcoidosis is a systemic inflammatory syndrome of unknown etiology and cardiac involvement has been reported to be an important prognostic factor in this disease. An autopsy study has reported that the frequency of this cardiac involvement (cardiac sarcoidosis: CS) varies in the different countries and races and very frequent in Japanese patients. We therefore performed the nationwide questionnaire survey and try to clarify the clinical characteristics and corticosteroid effect in CS, especially focused on arrhythmic events in this disease.
Methods
Total of 757 Japanese patients from 57 hospitals who diagnosed CS were examined. Patients who unsatisfied the criteria of the Japanese new guidelines, or who underwent cardiac transplantations were excluded, and 420 patients (287 females, median follow-up periods 1864 days [interquartile range: 845–3159 days]) were analyzed. The clinical outcome and corticosteroid effect were evaluated.
Results
Clinical characteristics at diagnosis was as follows: female dominant (68%), mean age of 60±13 years old, mean left ventricular ejection fraction was 49±16%. Arrhythmic events were very frequently observed as an initial cardiac manifestation in 263 patients (62%) of CS, of which atrioventricular block (AVB) in 174 (41%), ventricular tachycardia (VT) in 73 (17%) and AVB with VT in 17 (4%) (Figure 1A). Pacemaker was implanted in 166 patients (40%) and defibrillators was 137 patients (33%). Corticosteroid was prescribed in 144 (83%) of 174 patients with AVB and in 62 (85%) of 73 patients with VT. Initial dose was mean 47.9 mg and maintenance dose of mean 7.3 mg. Corticosteroid improved VT as good as AVB (27% vs. 29%). However, corticosteroid sometimes worsened VT events compared with AVB (10% vs. 2%) (Figure 1B). During the course of follow-up, 32 patients were needed to increase corticosteroid in 23 of AVB and 10 of VT cases. However, there were no difference in mortality between the groups, whether or not to increase corticosteroid. All survival rate was 92% (5-year mortality), 83% (10-year mortality) and free from all cause death and defibrillator charge was 81% (5 year), 71% (10 year).
Conclusion
Fatal arrhythmia is commonly observed in CS as a primary symptom. Corticosteroid sometimes worsen ventricular arrhythmia and appropriate defibrillator discharge was common. Thus, careful attention for activating ventricular arrhythmia would be needed during the follow-up period even after corticosteroid therapy.
Funding Acknowledgement
Type of funding source: None
Collapse
|
13
|
Long-term follow up ventricular tachycardia patients with preserved cardiac function -from Japanese cardiac sarcoidosis nationwide questionnaire survey-. Eur Heart J 2020. [DOI: 10.1093/ehjci/ehaa946.2128] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Background
Prior ventricular tachycardia (VT) and low left ventricular ejection fraction (LVEF) are the most important prognostic factors in cardiac sarcoidosis (CS). Recently diagnosis of CS was renewed according to Japanese new guidelines. Patients with preserved cardiac function often have VT events, thus new guidelines recommends to assess the implantable cardioverter defibrillator (ICD) implantation for CS patients with preserved LVEF (35%≤LVEF<50%). However, the long-term prognosis of CS patients with preserved LVEF is unclear.
Objective
In CS patients with preserved LVEF, we evaluated the prognosis between VT manifestation and non-VT manifestation groups at CS diagnosis from Japanese nationwide questionnaire survey.
Methods
Total of 757 Japanese patients from 57 hospitals who diagnosed CS were examined. Patients who unsatisfied the criteria of the Japanese new guidelines, who had LVEF≤35%, LVEF>50%, or who underwent cardiac transplantations were excluded. 104 patients with LVEF 35–50% (67 females, mean age 60±15 years old, median follow-up periods 2134 days [interquartile range: 758–2935 days]) were analyzed. The prognosis between VT manifestation and non-VT manifestation groups at CS diagnosis were evaluated.
Results
30 patients had VT manifestation at CS diagnosis and 24 patients (80%) received ICDs. 74 patients had no VT manifestation at CS diagnosis and 19 patients (44%) received ICDs during follow up period. All-cause mortality was not different between two groups (Figure). Appropriate ICD therapy of non-VT manifestation group was significantly lower compared with that of VT manifestation group (log-rank p=0.001), however considerable number (n=7, 15%) of non-VT manifestation group had appropriate ICD therapy event during follow-up period. Cox hazard analysis revealed that concomitant non-sustained VT (NSVT) with atrioventricular block (AVB) was a predictor of appropriate ICD therapy in non-VT manifestation group.
Conclusion
This nationwide survey showed that considerable number of CS patients with preserved LVEF had VT events, independent of VT manifestation. Concomitant NSVT with AVB was a predictor of VT events, and ICD implantation should be assessed.
Funding Acknowledgement
Type of funding source: None
Collapse
|
14
|
Percutaneous transluminal septal myocardial ablation markedly reduces energy loss in hypertrophic obstructive cardiomyopathy: a four-dimensional flow magnetic resonance imaging study. Eur Heart J 2020. [DOI: 10.1093/ehjci/ehaa946.2081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Background
Functional follow-up modalities of hypertrophic obstructive cardiomyopathy (HOCM) subjected to percutaneous transluminal septal myocardial ablation (PTSMA) are limited mainly to echocardiography and catheterization. Recent advancements in four-dimensional (4D) flow magnetic resonance imaging (MRI) have enabled us to assess patients from the perspective of fluid dynamics by visualising blood flow and calculating quantitative parameters such as wall shear stress and energy loss within cardiac chambers or blood vessels. Several reports have demonstrated that the intra-cardiac energy loss decreased along with improvement of cardiac function achieved by treatment of cardiac diseases. Whether changes in energy loss occur along with PTSMA in HOCM patients and the underlying mechanism remain unknown.
Purpose
This study sought to investigate the influence of PTSMA in patients with HOCM on energy loss in the left ventricle (LV) and aortic root measured by 4D flow MRI.
Methods
We retrospectively recruited HOCM patients who underwent PTSMA at a referral centre from May to November 2019. Patients who underwent 4D flow MRI both before and after PTSMA were included. We collected demographic and clinical data from electronic health records. MRI scans implemented two-dimensional phase-contrast imaging of the three-chamber plane with three-directional velocity, using a 1.5 T scanner. Furthermore, 4D blood flow analysis was performed on off-line saved data, using iTFlow version 1.9. We assessed energy loss in one cardiac cycle within the three-chamber plane of the LV and aortic root (area surrounded by the LV endocardium, sinotubular junction, and mitral annulus).
Results
This study finally included 12 patients, whose mean age was 66±12 years, and 5 (42%) of whom were men. The pressure gradient between the LV apex and ascending aorta was 81±32 mmHg before and 20±22 mmHg immediately after PTSMA (P<0.005, paired). Before PTSMA, 6 patients were in New York Heart Association functional class III and the other 6 in class II. However, after PTSMA, 10 patients improved to class I and 2 to class II. PTSMA reduced energy loss in one cardiac cycle within the three-chamber plane of the LV and aortic root, from 79±36 mJ/m to 55±19 mJ/m (P=0.001, paired).
Conclusions
PTSMA in patients with HOCM reduced energy loss within the LV and aortic root, indicating significant decrease with cardiac workload. Four-dimensional flow MRI of the three-chamber plane to assess energy loss within the LV and aortic root is a time-efficient and reproducible quantitative method to evaluate the effects of PTSMA. Given its non-invasive nature, it also enables to sequentially follow-up HOCM patients who underwent PTSMA.
Periprocedural changes of energy loss
Funding Acknowledgement
Type of funding source: None
Collapse
|
15
|
Neutron-induced signal on the single crystal chemical vapor deposition diamond-based neutral particle analyzer. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2020; 91:113304. [PMID: 33261440 DOI: 10.1063/5.0020460] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Accepted: 10/29/2020] [Indexed: 06/12/2023]
Abstract
A diamond-based neutral particle analyzer (DNPA) array composed of single-crystal chemical vapor deposition (sCVD) diamond detectors was installed on the Large Helical Device (LHD) for measuring the helically trapped energetic particles. In high neutron flux experiments, the unwanted neutron-induced pulse counting rate should be estimated using the neutron diagnostics because a diamond detector is sensitive to neutrons as well as energetic neutral particles. In order to evaluate the quantitative neutron-induced pulse counting rate on the DNPA, the response functions of the sCVD diamond detector for mono-energetic neutrons were obtained using accelerator-based D-D and D-7Li neutron sources in Fast Neutron Laboratory (FNL). As a result of the neutron flux estimation by the Monte Carlo N-Particle code at the NPA position in the LHD and the response function obtained in the FNL experiment, the counting rate of the neutron-induced signal was predicted to be 1.1 kcps for the source neutron emission rate of Sn = 1 × 1015 n/s. In the LHD experiment, the neutron-induced signals were observed by closing the gate valve during the plasma discharges. It is found that the counting rates of the neutron-induced signals proportional to Sn reached 1.1 kcps at Sn = 1 × 1015 n/s. As a result of the quantitative estimation of the neutron-induced signals on the DNPA using other neutron measurements, it has become possible to accurately measure energetic neutral particles in the high neutron flux experiment.
Collapse
|
16
|
Performance of the newly installed vertical neutron cameras for low neutron yield discharges in the Large Helical Device. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2020; 91:083505. [PMID: 32872928 DOI: 10.1063/5.0010302] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Accepted: 07/24/2020] [Indexed: 06/11/2023]
Abstract
Two new vertical neutron cameras characterized by high detection efficiency were developed on the Large Helical Device in order to observe poloidal structures of helically trapped beam ions created by the perpendicularly injected positive-ion based neutral beam (P-NB) and are newly operated since 2018. In this work, the neutron fields at the vertical neutron cameras are investigated using the Monte Carlo N-particle transport code to evaluate the performance of its collimators. The results indicate that neutrons are attenuated by the heavy concrete and are well collimated through the collimator to detectors. Neutron spectra at the detector position show over 99% of uncollided 2.45 MeV neutrons. Time evolution of neutron emission profiles during the short pulse of P-NB injection is measured by the vertical neutron cameras. Peaks on the neutron emission profiles corresponding to the helically trapped beam ion are successfully obtained, as designed. The decrease in line integrated neutron flux at the peak positions after the P-NB stops is consistent with the behavior of the total neutron emission rate measured by the neutron flux monitor.
Collapse
|
17
|
Design optimization of a fast-neutron detector with scintillating fibers for triton burnup experiments at fusion experimental devices. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2019; 90:043503. [PMID: 31043024 DOI: 10.1063/1.5074131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2018] [Accepted: 03/22/2019] [Indexed: 06/09/2023]
Abstract
Time-resolved triton burnup studies have been carried out to estimate the behavior of alpha particles in DD fusion experimental devices. In those studies, 14 MeV neutrons emitted through DT reactions in DD plasmas should be measured selectively in the backgrounds of DD neutrons and gamma rays. For this purpose, a scintillating-fiber (Sci-Fi) based fast-neutron detector has been adapted because of its advantages such as fast response, design flexibility in detection efficiency by changing the number of Sci-Fi, and discrimination property against 2.4 MeV neutrons produced through DD reactions and gamma rays. However, its length had conventionally been set to around 10 cm without an optimization study of its design parameters to meet the requirements as 14 MeV neutron detector. In the present study, we tested three types of Sci-Fi detectors with three different lengths and compared with the simulated results of energy deposition, through which we tried to understand the phenomena in the detection process of fast neutrons. From the results, it has been shown that, due to the self-shielding of neutrons by Sci-Fi and the attenuation of scintillation photons during the transmission process to the photomultiplier tube, the optimal length of Sci-Fi is concluded to be about 6 cm.
Collapse
|
18
|
Abstract
One-dimensional magnets, where spins interact only along a particular spatial direction, are of special interest due to their quantum mechanical behaviors, viz., spin liquid, spin glass, quantum phase transition, even superconductivity etc.
Collapse
|
19
|
Density profile measurement with a heavy ion beam probe in a toroidal plasma of the compact helical system. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:113507. [PMID: 30501308 DOI: 10.1063/1.5039571] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2018] [Accepted: 10/19/2018] [Indexed: 06/09/2023]
Abstract
A possibility of electron density measurements with heavy ion beam probes (HIBPs) has been demonstrated, along with their capability to measure the potential and magnetic field. A method has been proposed to reconstruct the electron density profile [A. Fujisawa et al., Rev. Sci. Instrum. 74, 3335 (2003)]. In the method, the profile of secondary beam currents is converted into a local density profile by taking into account local brightness and so-called path integral effects which mean the effect of beam attenuation along the beam orbit. Here the article presents the HIBP measurement of the electron density profile after the proposed method was first applied on the real experimental data of compact helical system plasmas. In the real application, the hollow density and the peaked profiles are successfully obtained with sufficiently high temporal resolution (a few ms), in accordance with the electron density profile measured with Thomson scattering for electron cyclotron resonance heating and neutral beam injection plasmas.
Collapse
|
20
|
The large helical device vertical neutron camera operating in the MHz counting rate range. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:113509. [PMID: 30501311 DOI: 10.1063/1.5054818] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/04/2018] [Accepted: 11/02/2018] [Indexed: 06/09/2023]
Abstract
In the currently performed neutral beam (NB) -heated deuterium plasma experiments, neutrons are mainly produced by a beam-plasma reaction. Therefore, time-resolved measurement of the neutron emission profile can enhance the understanding of the classical and/or anomalous transport of beam ions. To measure radial neutron emission profiles as a function of time, the vertical neutron camera (VNC) capable of operation with a counting rate in the MHz range was newly installed on the Large Helical Device (LHD). This is the world's first neutron camera for stellarator/heliotron devices. The VNC consists of a multichannel collimator, eleven fast-neutron detectors, and the digital-signal-processing-based data acquisition system (DAQ). The multichannel collimator having little cross talk was made from hematite-doped heavy concrete, which has a high shielding performance against both neutrons and gamma-rays. A stilbene crystal coupled with a photomultiplier having high-gain-stability in the high-count rate regime was utilized as a fast-neutron scintillation detector because it has a high neutron-gamma discrimination capability at high count rates. The DAQ system equipped with a field programmable logic controller was developed to obtain the waveform acquired with a 1 GHz sampling rate and the shaping parameter of each pulse simultaneously at up to 106 cps (counts per second). Neutron emission profiles were successfully obtained in the first deuterium campaign of LHD in 2017. The neutron emission profile was measured in tangentially co-injected NB-heated plasma with different magnetic axes (R ax). The neutron counts became larger in the inward-shifted configuration, which was consistent with the total neutron rate measured by the neutron flux monitor. The radial peak position of the line-integrated neutron profile which changed according to R ax showed that the VNC worked successfully as designed. The VNC demonstrated the expected performance conducive to extending energetic-particle physics studies in LHD.
Collapse
|
21
|
Performance of fast-ion loss diagnostic on EAST. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:10I144. [PMID: 30399726 DOI: 10.1063/1.5038782] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2018] [Accepted: 09/05/2018] [Indexed: 06/08/2023]
Abstract
The scintillator-based detector for fast-ion loss measurements has been installed on EAST. To obtain high temporal resolution for fast-ion loss diagnostics, fast photomultiplier tube systems have been developed which can supply the complementary measurements to the previous image system with good energy and pitch resolution by using a CCD camera. By applying the rotatable platform, the prompt losses of beam-ions can be measured in normal and reverse magnetic field. The thick-target bremsstrahlung occurring in the stainless steel shield with energetic electrons can produce X-rays, which will strike on the scintillator based detector. To understand this interference on fast-ion loss signals, the effects of energetic electrons on the scintillator-based detector are studied, including runaway electrons in the plasma ramping-up phase and fast electrons accelerated by the lower hybrid wave.
Collapse
|
22
|
Initial operation results of NE213 scintillation detector for time-resolved measurements on triton burnup in KSTAR. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:10I118. [PMID: 30399758 DOI: 10.1063/1.5039308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Accepted: 07/29/2018] [Indexed: 06/08/2023]
Abstract
In time-resolved measurement for triton burnup in Korea Superconducting Tokamak Advanced Research (KSTAR) deuterium plasmas, an NE213 liquid scintillation detector was installed and operated during the 2017 KSTAR campaign. The detector is composed of an NE213 scintillator (50 mm in diameter and 10 mm in thickness) and a photomultiplier tube (PMT). The PMT anode signal was processed under a data acquisition system which contains a field programmable gate array circuit and pulse processing software that is capable of discriminating gamma-ray and neutron pulse signals. In order to determine an appropriate threshold level for the 14 MeV neutron signal resulting from triton burnup, the NE213 scintillation detector was calibrated by using d-d and d-t neutron generators at the National Fusion Research Institute and Intense 14 MeV Neutron Source Facility, OKTAVIAN, Osaka University, Japan. The detector was installed on KSTAR with a 10 mm thick soft-iron stray magnetic field shield and a radiation shield which consists of 100 mm thick lead blocks and 200 mm thick borated polyethylene blocks. A discrimination range for d-t neutron was determined based on test results from neutron generators and KSTAR. Data points selected from the discrimination range were consistent with the classical triton confinement characteristics. In conclusion, under condition of an input counting rate of 1.9 × 105 counts per second (CPS), the detector is able to measure triton burnup signals up to 500 CPS for various plasma parameters.
Collapse
|
23
|
P632Usefulness of the percentage of predicted value of VE vs. VCO2 slope. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy564.p632] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
24
|
Integrated radiation monitoring and interlock system for the LHD deuterium experiments. FUSION ENGINEERING AND DESIGN 2018. [DOI: 10.1016/j.fusengdes.2018.02.067] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
25
|
Mode of action and synergistic effect of valinomycin and cereulide with amphotericin B against Candida albicans and Cryptococcus albidus. J Mycol Med 2017; 28:112-121. [PMID: 29276078 DOI: 10.1016/j.mycmed.2017.11.007] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2017] [Revised: 11/22/2017] [Accepted: 11/29/2017] [Indexed: 11/16/2022]
Abstract
Both valinomycin and cereulide are cyclic depsipeptides and are known K+ ion-selective ionophores. Valinomycin and cereulide feature low minimum inhibitory concentration (MIC) values against Candida albicans and Cryptococcus albidus. This study aims at investigating the mode of action and verifying the efficacy of valinomycin or cereulide alone and in combination with amphotericin B (AmB) in vitro against both microorganisms. Based on the results from membrane permeability and fluidity assays for detection of plasma membrane permeabilization and membrane dynamics, the present study demonstrated that valinomycin and cereulide exhibit antifungal activity against C. albicans and C. albidus by interrupting membrane-associated function. The mode of action of both valinomycin and cereulide are similar with that of AmB. Time-kill kinetics assay showed that valinomycin and cereulide exhibit fungistatic activity, whereas AmB features fungicidal activity. Additionally, the combination of compounds between each cyclic peptide and AmB reached maximal fungicidal activity more rapidly than AmB alone. This result corresponded with findings of scanning electron microscopy, fractional inhibitory concentration index and minimum fungicidal concentration (MFC)/MIC ratio, indicating that combinations of the drugs show synergistic effects for inhibiting the growth of these fungal strains. Sorbitol and ergosterol assays showed that both cyclic peptides affected cell wall and membrane components due to increases in MIC value, as observed in medium with sorbitol and ergosterol. Valinomycin and cereulide may promote permeability of fungal cell wall and cell membrane when used in combination with AmB.
Collapse
|
26
|
Associations among tooth loss, systemic inflammation and antibody titers to periodontal pathogens in Japanese patients with cardiovascular disease. J Periodontal Res 2017; 53:117-122. [DOI: 10.1111/jre.12494] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/26/2017] [Indexed: 11/29/2022]
|
27
|
P2.07-018 Correlation of Clinical Response and XAGE1 Immunity in Lung Adenocarcinoma. J Thorac Oncol 2017. [DOI: 10.1016/j.jtho.2017.11.077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
28
|
P2.07-015 Reviving Chemotherapy Sensitivity after Anti-CCR4 mAb (Mogamulizumab) Treatment in Lung Cancer Patients. J Thorac Oncol 2017. [DOI: 10.1016/j.jtho.2017.11.074] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
29
|
In situ calibration of neutron activation system on the large helical device. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2017; 88:113302. [PMID: 29195381 DOI: 10.1063/1.5009475] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
In situ calibration of the neutron activation system on the Large Helical Device (LHD) was performed by using an intense 252Cf neutron source. To simulate a ring-shaped neutron source, we installed a railway inside the LHD vacuum vessel and made a train loaded with the 252Cf source run along a typical magnetic axis position. Three activation capsules loaded with thirty pieces of indium foils stacked with total mass of approximately 18 g were prepared. Each capsule was irradiated over 15 h while the train was circulating. The activation response coefficient (9.4 ± 1.2) × 10-8 of 115In(n, n')115mIn reaction obtained from the experiment is in good agreement with results from three-dimensional neutron transport calculations using the Monte Carlo neutron transport simulation code 6. The activation response coefficients of 2.45 MeV birth neutron and secondary 14.1 MeV neutron from deuterium plasma were evaluated from the activation response coefficient obtained in this calibration experiment with results from three-dimensional neutron calculations using the Monte Carlo neutron transport simulation code 6.
Collapse
|
30
|
P5466Sex difference in the response to cardiac resynchronization therapy in patients with cardiac sarcoidosis: from Japanese multi-center retrospective cohort analysis. Eur Heart J 2017. [DOI: 10.1093/eurheartj/ehx493.p5466] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
31
|
Probabilistic n/γ discrimination with robustness against outliers for use in neutron profile monitors. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2017; 88:083504. [PMID: 28863667 DOI: 10.1063/1.4996177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
A method to stochastically discriminate neutron and γ-ray signals measured with a stilbene organic scintillator is proposed. Each pulse signal was stochastically categorized into two groups: neutron and γ-ray. In previous work, the Expectation Maximization (EM) algorithm was used with the assumption that the measured data followed a Gaussian mixture distribution. It was shown that probabilistic discrimination between these groups is possible. Moreover, by setting the initial parameters for the Gaussian mixture distribution with a k-means algorithm, the possibility of automatic discrimination was demonstrated. In this study, the Student's t-mixture distribution was used as a probabilistic distribution with the EM algorithm to improve the robustness against the effect of outliers caused by pileup of the signals. To validate the proposed method, the figures of merit (FOMs) were compared for the EM algorithm assuming a t-mixture distribution and a Gaussian mixture distribution. The t-mixture distribution resulted in an improvement of the FOMs compared with the Gaussian mixture distribution. The proposed data processing technique is a promising tool not only for neutron and γ-ray discrimination in fusion experiments but also in other fields, for example, homeland security, cancer therapy with high energy particles, nuclear reactor decommissioning, pattern recognition, and so on.
Collapse
|
32
|
Current Status of Large Helical Device and Its Prospect for Deuterium Experiment. FUSION SCIENCE AND TECHNOLOGY 2017. [DOI: 10.1080/15361055.2017.1335145] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
33
|
|
34
|
Reheat Mode Discharges in Search of Attainable High Stored Energy and Density Limit of Compact Helical System. FUSION SCIENCE AND TECHNOLOGY 2017. [DOI: 10.13182/fst06-a1240] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
35
|
|
36
|
|
37
|
|
38
|
|
39
|
Experimental Observations of O-X-B Heating of Overdense Plasmas in CHS. FUSION SCIENCE AND TECHNOLOGY 2017. [DOI: 10.13182/fst07-a1500] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
40
|
|
41
|
Effect of Neoclassical Transport Optimization on Energetic Ion Confinement in LHD. FUSION SCIENCE AND TECHNOLOGY 2017. [DOI: 10.13182/fst04-a561] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
42
|
Optimization of Electron Cyclotron Current Drive in the Magnetic Field Configuration of CHS. FUSION SCIENCE AND TECHNOLOGY 2017. [DOI: 10.13182/fst08-a1652] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
43
|
Suppression of Trapped Energetic Ions Driven Resistive Interchange Modes with Electron Cyclotron Heating in a Helical Plasma. PHYSICAL REVIEW LETTERS 2017; 118:125001. [PMID: 28388197 DOI: 10.1103/physrevlett.118.125001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2016] [Indexed: 06/07/2023]
Abstract
The resistive interchange mode destabilized by the resonant interaction with the trapped energetic ions is fully suppressed when the injected power of electron cyclotron heating exceeds a certain threshold. It is shown for the first time that the complete stabilization of the energetic-particle-driven mode without relaxing the energetic particle (EP) pressure gradient is possible by reducing the radial width of the eigenmodes δ_{w}, especially when δ_{w} narrows to a small enough value relative to the finite orbit width of EP.
Collapse
|
44
|
Scintillator-based fast ion loss measurements in the EAST. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:11E728. [PMID: 27910330 DOI: 10.1063/1.4962245] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A new scintillator-based fast ion loss detector (FILD) has been installed on Experimental Advanced Superconducting Tokamak (EAST) to investigate the fast ion loss behavior in high performance plasma with neutral beam injection (NBI) and ion cyclotron resonance heating (ICRH). A two dimensional 40 mm × 40 mm scintillator-coated (ZnS:Ag) stainless plate is mounted in the front of the detector, capturing the escaping fast ions. Photons from the scintillator plate are imaged with a Phantom V2010 CCD camera. The lost fast ions can be measured with the pitch angle from 60° to 120° and the gyroradius from 10 mm to 180 mm. This paper will describe the details of FILD diagnostic on EAST and describe preliminary measurements during NBI and ICRH heating.
Collapse
|
45
|
Faraday-cup-type lost fast ion detector on Heliotron J. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:11D818. [PMID: 27910618 DOI: 10.1063/1.4960310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A Faraday-cup type lost-fast ion probe (FLIP) has been designed and installed in Heliotron J for the purpose of the studies of interaction between fast ions and MHD instabilities. The FLIP can measure the co-going fast ions whose energy is in the range of 1.7-42.5 keV (proton) and pitch angle of 90∘-140∘, especially for fast ions having the injection energy of neutral beam injection (NBI). The FLIP successfully measured the re-entering passing ions and trapped lost-fast ions caused by fast-ion-driven energetic particle modes in NBI heated plasmas.
Collapse
|
46
|
Development of fast neutron pinhole camera using nuclear emulsion for neutron emission profile measurement in KSTAR. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:11D840. [PMID: 27910454 DOI: 10.1063/1.4963866] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
We have developed a compact fast neutron camera based on a stack of nuclear emulsion plates and a pinhole collimator. The camera was installed at J-port of Korea superconducting tokamak advanced research at National Fusion Research Institute, Republic of Korea. Fast neutron images agreed better with calculated ones based on Monte Carlo neutron simulation using the uniform distribution of Deuterium-Deuterium (DD) neutron source in a torus of 40 cm radius.
Collapse
|
47
|
Triton burnup measurements in KSTAR using a neutron activation system. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:11D828. [PMID: 27910448 DOI: 10.1063/1.4961273] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Measurements of the time-integrated triton burnup for deuterium plasma in Korea Superconducting Tokamak Advanced Research (KSTAR) have been performed following the simultaneous detection of the d-d and d-t neutrons. The d-d neutrons were measured using a 3He proportional counter, fission chamber, and activated indium sample, whereas the d-t neutrons were detected using activated silicon and copper samples. The triton burnup ratio from KSTAR discharges is found to be in the range 0.01%-0.50% depending on the plasma conditions. The measured burnup ratio is compared with the prompt loss fraction of tritons calculated with the Lorentz orbit code and the classical slowing-down time. The burnup ratio is found to increase as plasma current and classical slowing-down time increase.
Collapse
|
48
|
Abnormal asymmetries in subcortical brain volume in schizophrenia. Mol Psychiatry 2016; 21:1460-6. [PMID: 26782053 PMCID: PMC5030462 DOI: 10.1038/mp.2015.209] [Citation(s) in RCA: 238] [Impact Index Per Article: 29.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2015] [Revised: 11/06/2015] [Accepted: 11/13/2015] [Indexed: 12/31/2022]
Abstract
Subcortical structures, which include the basal ganglia and parts of the limbic system, have key roles in learning, motor control and emotion, but also contribute to higher-order executive functions. Prior studies have reported volumetric alterations in subcortical regions in schizophrenia. Reported results have sometimes been heterogeneous, and few large-scale investigations have been conducted. Moreover, few large-scale studies have assessed asymmetries of subcortical volumes in schizophrenia. Here, as a work completely independent of a study performed by the ENIGMA consortium, we conducted a large-scale multisite study of subcortical volumetric differences between patients with schizophrenia and controls. We also explored the laterality of subcortical regions to identify characteristic similarities and differences between them. T1-weighted images from 1680 healthy individuals and 884 patients with schizophrenia, obtained with 15 imaging protocols at 11 sites, were processed with FreeSurfer. Group differences were calculated for each protocol and meta-analyzed. Compared with controls, patients with schizophrenia demonstrated smaller bilateral hippocampus, amygdala, thalamus and accumbens volumes as well as intracranial volume, but larger bilateral caudate, putamen, pallidum and lateral ventricle volumes. We replicated the rank order of effect sizes for subcortical volumetric changes in schizophrenia reported by the ENIGMA consortium. Further, we revealed leftward asymmetry for thalamus, lateral ventricle, caudate and putamen volumes, and rightward asymmetry for amygdala and hippocampal volumes in both controls and patients with schizophrenia. Also, we demonstrated a schizophrenia-specific leftward asymmetry for pallidum volume. These findings suggest the possibility of aberrant laterality in neural pathways and connectivity patterns related to the pallidum in schizophrenia.
Collapse
|
49
|
Durability of Flexible Molded Polyurethane Foams. J CELL PLAST 2016. [DOI: 10.1177/0021955x9803400605] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
In recent years, we have developed highly resilient (HR) flexible molded foams with superb durability, resilience and vibration characteristics, and we have reported that these improvements were based on control of cross link degree of polymer, morphology and mobility of hard and soft segments. This paper describes factors that dominantly influence the durability and the mechanism of fatigue by investigation of cross linking by covalent and hydrogen-bonds and the morphology of hard/soft segments. In this study, we use molded foams with different durabilities. These are TDI-based high performance/conventional HR, MDI-based high-performance/conventional HR, and hot molded foams. On the whole, a small apparent viscosity coefficient, which is calculated from vibration characteristics of the foam, and a higher cross link degree of foam polymer make static and dynamic durability of flexible molded foam better. Mobility of the soft segment, estimated by solid state NMR, also dominates dynamic durability. Accordingly, hydrogen-bonds of the hard segment contribute against creep as a cross link point in static/dynamic durability test, and tight hydrogen-bonds of hot molded foam are durable against rupture or rebonding by water molecules in the wet compression set oven. The drop in cross link degree of foam polymer was not observed during vibration durability test. Accordingly, the mechanism of fatigue could be the change of state in hydrogen-bonds or tangling of polymer-chains, or relatively macro rupture.
Collapse
|
50
|
Development of the radial neutron camera system for the HL-2A tokamak. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:063503. [PMID: 27370450 DOI: 10.1063/1.4953109] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A new radial neutron camera system has been developed and operated recently in the HL-2A tokamak to measure the spatial and time resolved 2.5 MeV D-D fusion neutron, enhancing the understanding of the energetic-ion physics. The camera mainly consists of a multichannel collimator, liquid-scintillation detectors, shielding systems, and a data acquisition system. Measurements of the D-D fusion neutrons using the camera have been successfully performed during the 2015 HL-2A experiment campaign. The measurements show that the distribution of the fusion neutrons in the HL-2A plasma has a peaked profile, suggesting that the neutral beam injection beam ions in the plasma have a peaked distribution. It also suggests that the neutrons are primarily produced from beam-target reactions in the plasma core region. The measurement results from the neutron camera are well consistent with the results of both a standard (235)U fission chamber and NUBEAM neutron calculations. In this paper, the new radial neutron camera system on HL-2A and the first experimental results are described.
Collapse
|