1
|
Tallarico M, Kim YJ, Cocchi F, Martinolli M, Meloni SM. Accuracy of newly developed sleeve-designed templates for insertion of dental implants: A prospective multicenters clinical trial. Clin Implant Dent Relat Res 2018; 21:108-113. [DOI: 10.1111/cid.12704] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Revised: 10/21/2018] [Accepted: 10/25/2018] [Indexed: 11/30/2022]
|
|
7 |
40 |
2
|
Tallarico M, Ceruso FM, Muzzi L, Meloni SM, Kim YJ, Gargari M, Martinolli M. Effect of Simultaneous Immediate Implant Placement and Guided Bone Reconstruction with Ultra-Fine Titanium Mesh Membranes on Radiographic and Clinical Parameters after 18 Months of Loading. MATERIALS 2019; 12:ma12101710. [PMID: 31130717 PMCID: PMC6566839 DOI: 10.3390/ma12101710] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/05/2019] [Revised: 05/14/2019] [Accepted: 05/22/2019] [Indexed: 11/16/2022]
Abstract
Background: The aim of the present prospective case series study was to evaluate the implant and prosthetic survival rates, complications and marginal bone loss using ultra-fine titanium mesh membrane with simultaneous implant placement, to provide space maintenance mandatory for guided bone reconstruction of alveolar bone defects. Materials and Methods: patients were recruited and treated at a private clinic in Rome, Italy, between March 2016 and October 2017. Self-tapping tapered implants were placed through a computer-guided template-assisted approach. Autogenous bone was placed alone over the exposed implant surface, then mixed with inorganic bovine bone material. Finally, the membrane was connected and shaped in order to securely enclose the graft area, and the healing cap was connected and screwed onto the height connector. Outcome measures were: implant and prosthetic failure, biological and mechanical complications, marginal and volumetric bone level changes, esthetic evaluation performed according to the pink aesthetic score (PES). Results: in total, seven patients (five women, two men) with a mean age of 52.7 ± 20.3 years (range: 27–71) received 10 self-tapping tapered implants and simultaneous guided bone regeneration with ultra-fine titanium mesh membranes. No implants and no prostheses failed during the entire follow-up period. One slightly membrane exposure was observed one month after implant placement in one patient. The mean marginal bone loss (MBL) at implant loading was 0.13 ± 0.09 mm (95% CI 0.08–0.19). At the 18-month follow-up examination, the mean MBL was 0.28 ± 0.33 mm (95% CI 0.07–0.50) The difference was not statistically significant (0.15 ± 0.31; 95% CI 0.05–0.35; P = 0.1888). The mean horizontal alveolar ridge width was 3.72 ± 1.08 mm (95% CI 3.22–4.22 mm). At the II-stage surgery, the mean bone width was 8.79 ± 0.98 mm (95% CI 8.51–9.07 mm). The mean bone gain was 5.06 ± 1.13 mm (95% CI 4.68–5.44 mm; P = 0.000). The mean volume of the grafted bone calculated using the superimposition technique was 0.99 ± 0.38 CC (95% CI 0.75–1.23 CC). The mean PES at implant loading was 8.2 ± 0.8 mm (95% CI 7.7–8.7). At the 18-month follow-up examination, the mean PES was 12.0 ± 0.7 mm (95% CI 11.5–12.5) The difference was statistically significant (3.8 ± 0.4; 95% CI 3.5–4.1; P = 0.0000); Conclusion: with the limitation of the present prospective study, the guided bone reconstruction using an ultra-fine titanium mesh membrane with simultaneous implant placement seems to provide good and stable results in implant/prosthesis success. Further research with a longer follow-up and a higher sample size are needed to confirm the results from this preliminary report.
Collapse
|
Journal Article |
6 |
18 |
3
|
Gonçalves TMSV, Bortolini S, Martinolli M, Alfenas BFM, Peruzzo DC, Natali A, Berzaghi A, Garcia RCMR. Long-term Short Implants Performance: Systematic Review and Meta-Analysis of the Essential Assessment Parameters. Braz Dent J 2015; 26:325-36. [DOI: 10.1590/0103-6440201300265] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2014] [Accepted: 04/07/2015] [Indexed: 11/22/2022] Open
Abstract
<p>Lack of standard criteria in the outcome assessment makes it difficult to draw conclusions on the clinical performance of short implants and, under these circumstances, determine the reasons for implant failure. This study evaluated, through a systematic review of the literature and meta-analysis, the essential parameters required to assess the long-term clinical performance of short and extra-short implants. Electronic databases (Pubmed-MEDLINE, Cochrane Library Database, Embase, and Lilacs) were searched by two independent reviewers, without language limitation, to identify eligible papers. References from the selected articles were also reviewed. The review included clinical trials involving short dental implants placed in humans, published between January 2000 and March 2014, which described the parameters applied for outcome's measurements and provided data on survival rates. Thirteen methodologically acceptable studies were selected and 24 parameters were identified. The most frequent parameters assessed were the marginal bone loss and the cumulative implant survival rate, followed by implant failure rate and biological complications such as bleeding on probing and probing pocket depths. Only cumulative implant survival rate data allows meta-analysis revealing a positive effect size (from 0.052 (fixed) to 0.042 (random)), which means that short implant appears to be a successful treatment option. Mechanical complications and crown-to-implant (C/I) ratio measurement were also commonly described, however, considering the available evidence; no strong conclusions could be drawn since different methods were used to assess each parameter. By means of this literature review, a standard evaluation scheme is proposed, being helpful to regiment further investigations and comparisons on future studies.</p>
Collapse
|
|
10 |
18 |
4
|
Tallarico M, Ortensi L, Martinolli M, Casucci A, Ferrari E, Malaguti G, Montanari M, Scrascia R, Vaccaro G, Venezia P, Xhanari E, Rodriguez Y Baena R. Multicenter Retrospective Analysis of Implant Overdentures Delivered with Different Design and Attachment Systems: Results Between One and 17 Years of Follow-Up. Dent J (Basel) 2018; 6:E71. [PMID: 30544970 PMCID: PMC6313780 DOI: 10.3390/dj6040071] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2018] [Revised: 11/05/2018] [Accepted: 11/19/2018] [Indexed: 11/23/2022] Open
Abstract
PURPOSE To analyze implant and prosthetic survival rates, complications, patient satisfaction, and biological parameters of patients rehabilitated with implant overdentures (IOV) on splinted and nonsplinted implants and different attachment systems, in function for one to 17 years. METHODS This retrospective study evaluated data collected from patients rehabilitated with implant overdentures between January 2001 and December 2016 in nine different centers. Outcome measures were implant and prosthetic success rates, mechanical complications, marginal bone loss (MBL), oral health impact profile (OHIP), bleeding on probing, and plaque index. RESULTS A total of 581 implants were installed in 194 patients. Patients were followed for a mean period of 60.6 months (range 6⁻206). Eighty-nine patients received 296 low profile attachment (OT Equator), 62 patients received 124 ball attachments, and 43 patients received 107 Locator attachments. In eighty-three patients the implants were splinted with computer aided design/computer aided manufacturing (CAD/CAM) or casted bar. At the last follow-up, 10 implants failed in eight patients. Statistical significance was found for failed prostheses (P = 0.0723) and complications (P = 0.0165), with better values for splinted implants. No statistically significant differences were found in proportion of implant and prosthetic failure (P > 0.05). At a five-year follow-up, proportion of complications (P = 0.0289) and failed prostheses (P = 0.0069) were statistically higher for IOV on Locator attachments. No difference was founded in MBL at one- and two-year follow-up between different attachment systems (P > 0.05). Statistically significant improvement in all the OHIP categories was reported in all the patients, after one year of function. CONCLUSIONS Implant overdenture showed high implant and prosthetic survival rates, low complications, high patient satisfaction, and good biological parameters in the long-term follow-up. Splinting the implants may reduce number of mechanical complications. Locator attachments showed higher number of complications. Further studies are needed to confirm these preliminary results.
Collapse
|
research-article |
7 |
16 |
5
|
Tallarico M, Baldini N, Martinolli M, Xhanari E, Kim YJ, Cervino G, Meloni SM. Do the New Hydrophilic Surface Have Any Influence on Early Success Rate and Implant Stability during Osseointegration Period? Four-Month Preliminary Results from a Split-Mouth, Randomized Controlled Trial. Eur J Dent 2019; 13:95-101. [PMID: 31170768 PMCID: PMC6635964 DOI: 10.1055/s-0039-1688737] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] Open
Abstract
OBJECTIVE The objective of this study is to compare the implant stability of Hiossen ET III implants with its new hydrophilic (NH) surface and Hiossen ET III implants with the sandblasted and acid-etched (SA) surface. MATERIALS AND METHODS Patients required at least two teeth to be rehabilitated with a fixed, implant-supported restoration, consecutively enrolled. Patients randomly received SA surface implants (SA group) or SA implants with a newly developed bioabsorbable apatite nanocoating (NH group). Outcome measures were implant and prosthetic survival rate, complications, insertion torque, and implant stability quotient (ISQ) measured at implant placement and every week up to 8 weeks after implant placement. Comparison between groups was made by unpaired t-test, while the comparison between each follow-up will be made by paired t-tests to detect any change during the follow-up. Complications and failures were compared using Fisher's exact test. RESULTS A total of 14 patients were treated with 28 implants (14 SA and 14 NH). No implant and prosthesis failed 4 months after implant placement. No complications were experienced. At the 2nd week after implants placement, two implants in the SA group showed discontinuous measurements versus none in the NH group (p = 0.4815). Implants unscrewed during ISQ measurements and were rescrewed. Data recording stopped for 6 weeks. Both implants osseointegrated without any further complication. The NH implants did not show physiological ISQ decrease between 2nd and 4th week after implant placement, showing a more even pattern of ISQ values compared with SA implants (77.1 ± 4.6 vs. 72.9 ± 11.5; difference: 4.2 ± 12.1; p = 0.258). High ISQ values were found in both groups at each time point. CONCLUSIONS NH implants are a viable alternative to SA surface, as they seem to avoid the ISQ drop during the remodeling phase.
Collapse
|
Journal Article |
6 |
9 |
6
|
Tallarico M, Baldini N, Gatti F, Martinolli M, Xhanari E, Meloni SM, Gabriele C, Immacolata LA. Role of New Hydrophilic Surfaces on Early Success Rate and Implant Stability: 1-Year Post-loading Results of a Multicenter, Split-Mouth, Randomized Controlled Trial. Eur J Dent 2020; 15:1-7. [PMID: 33242915 PMCID: PMC7902108 DOI: 10.1055/s-0040-1713952] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
OBJECTIVE To compare early implant failure and implant stability of one-stage Hiossen ET III implants with its new hydrophilic (NH) surface, compared with Hiossen ET III implants with the sandblasted and acid-etched (SA) surface at 1-year follow-up. MATERIALS AND METHODS This study was designed as a split-mouth, multicenter randomized controlled trial aimed to compare SA surface implants (SA group) and NH surface, (NH group). Outcomes were implant and prosthetic survival rates, complications, the insertion torque at implant placement, and implant stability quotient (ISQ) values. RESULTS Twenty-nine patients (mean age 59.9 ± 11.3 years) were treated and followed up to 1 year after loading. No patient dropped out. Fifty-eight implants (29 SA group and 29 NH group) were placed. No implants or prostheses failed and no complications were experienced during follow-up. The mean insertion torque was 40.5 ± 3.23 (38.17-41.83) Ncm in the SA group and 40.48 ± 3.49 (38.02-41.98) Ncm in the NH group (p = 0.981). There was a statistically significant difference at the second week (T2) with higher values in the NH group (p = 0.041). Similar results were found in the maxilla (p = 0.045), but not in the mandible (p = 0.362). A positive correlation was found between initial insertion torque and ISQ with higher value in the NH group (0.73 vs. 0.66). CONCLUSIONS NH implants are a viable alternative to SA surface, as they seem to avoid the ISQ drop during the bone remodeling phase.
Collapse
|
Journal Article |
5 |
4 |
7
|
Ortensi L, Martinolli M, Borromeo C, Ceruso FM, Gargari M, Xhanari E, Tallarico M. Effectiveness of Ball Attachment Systems in Implant Retained- and Supported-Overdentures: A Three- to Five-Year Retrospective Examination. Dent J (Basel) 2019; 7:dj7030084. [PMID: 31480546 PMCID: PMC6784476 DOI: 10.3390/dj7030084] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Revised: 07/31/2019] [Accepted: 08/14/2019] [Indexed: 02/03/2023] Open
Abstract
Purpose: To evaluate implant and prosthetic survival rates, complications, patient satisfaction, and biological outcomes of patients rehabilitated with a ball attachment system for implant retained- and supported-overdentures (IOV), which was in function for 3 to 5 years. Methods: This retrospective study evaluated data collected from patients treated between April 2001 and May 2018 with IOV on splinted and non-splinted implants and a ball attachment system. Patients were followed for 36 to 206 months (mean follow-up was 128.1 ± 51.9 months). Data were collected at the 3- and 5-year follow-up examination. Outcome measures were implant and prosthetic survival rates, technical complications, marginal bone loss (MBL), oral health impact profile (OHIP), and periodontal parameters (bleeding on probing and plaque index). Results: A total of 46 patients (16 males and 30 females) with 124 implants were included in this study. Twenty-five implant-retained overdentures were delivered on 53 unsplinted implants, while the other 21 patients received an implant-supported overdentures and the implants were splinted. At the five-year follow-up examination, one implant and one prosthesis failed in the unsplinted group, resulting in a cumulative survival rate of 97.8% at the patient level. Two minor technical complications were experienced. Conclusions: Implant overdenture retained or supported by ball attachment systems showed high implant and prosthetic survival and success rates. A low number of complications, high patient satisfaction, and successful biological parameters were experienced in the mid-term follow-up. Data need to be confirmed by further randomized trials.
Collapse
|
Journal Article |
6 |
3 |
8
|
Martinolli M, Bortolini S, Natali A, Pereira LJ, Castelo PM, Rodrigues Garcia RCM, Gonçalves TMSV. Long‐term survival analysis of standard‐length and short implants with multifunctional abutments. J Oral Rehabil 2019; 46:640-646. [DOI: 10.1111/joor.12791] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2018] [Revised: 02/28/2019] [Accepted: 03/09/2019] [Indexed: 11/30/2022]
|
|
6 |
2 |
9
|
Tallarico M, Meloni SM, Martinolli M, Xhanari E. Accuracy of sleeveless surgical templates‐ one‐year randomized controlled trial. Clin Oral Implants Res 2019. [DOI: 10.1111/clr.23_13508] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
|
6 |
1 |
10
|
Tallarico M, Mario Meloni S, Martinolli M, Xhanari E, Baldini N, Kim Y. New hydrophilic implant surface‐ one‐year results from a split‐mouth RCT. Clin Oral Implants Res 2019. [DOI: 10.1111/clr.190_13509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
|
6 |
|
11
|
Tallarico M, Xhanari E, Kim YJ, Cocchi F, Martinolli M, Alushi A, Baldoni E, Meloni SM. Accuracy of computer-assisted template-based implant placement using conventional impression and scan model or intraoral digital impression: A randomised controlled trial with 1 year of follow-up. INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY (BERLIN, GERMANY) 2019; 12:197-206. [PMID: 31090750] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
PURPOSE To compare accuracy and complications of computer-assisted template-based implant placement using conventional impression and scan of a physical stone cast or intraoral scanning to rehabilitate partially edentulous patients. MATERIALS AND METHODS Any partially edentulous patients with at least five residual teeth, requiring at least one implant to be planned on three-dimensional (3D) cone beam computed tomography (CBCT) scan according to a computer-assisted template-based protocol were enrolled. Patients were randomised according to a parallel-group design into two arms: intraoral digital impression (fully digital group) or conventional impression and scan model (conventional group). Implants were placed flapless or with a minimally invasive flap, and conventionally loaded after 5 months. Outcome measures were implant and prosthetic success, complications, accuracy and peri-implant marginal bone loss. Three deviation parameters (angular, horizontal and vertical) were defined to evaluate the discrepancy between the planned and placed implant positions. Results were compared using a mixed-model repeated-measures analysis of variance (α = 0.05). RESULTS Twenty patients (11 females and 9 males; mean age 44.6 years old) were randomised to the fully digital group (10 patients with 28 implants) or conventional group (10 patients with 29 implants). No patients dropped out. No implant or prosthesis failed up to 1 year after loading. One implant in the fully digital group was placed freehand due to limited inter-arch space. No biological or mechanical complications were experienced during follow-up. Difference between groups were not statistically significant (P = 0.999). The mean error in angle was 2.25 ± 1.41 degrees (range 0.30 to 5.00 degrees; 95% CI: 1.38 to 3.12 degrees) in the fully digital group and 2.10 ± 1.18 degrees (range 0.30 to 5.80 degrees; 95% CI: 1.37 to 2.83 degrees) in the conventional group. The difference was not statistically significant (-0.15 ± 1.63 degrees; range -3.20 to 2.90 degrees; 95% CI: -0.87 to 0.57 degrees; P = 0.668); in the horizontal plane (mesio-distal), the mean error was 0.52 ± 0.30 mm (range 0.10 to 1.10 mm; 95% CI: 0.33 to 0.70 mm) in the fully digital group and 0.44 ± 0.26 mm (range 0.10 to 0.90 mm; 95% CI: 0.27 to 0.60 mm) in the conventional group. The difference was not statistically significant (-0.08 ± 0.38 degrees; range -1.0 to 0.60 degrees; 95% CI: -0.32 to 0.16 degrees; P = 0.279); in the vertical plane (apico-coronal), the mean error was 0.58 ± 0.44 mm (range 0.00 to 1.60 mm; 95% CI: 0.31 to 0.85) in the fully digital group and 0.46 ± 0.34 mm (range 0.00 to 1.20 mm; 95% CI: 0.25 to 0.67) in the conventional group. The difference was not statistically significant (-0.12 ± 0.59 degrees; range -1.20 to 1.00 degrees; 95% CI: -0.49 to 0.24 degrees; P = 0.250). One year after loading, the mean marginal bone loss was 0.14 ± 0.12 mm (range -0.10 to 0.40 mm; 95% CI: 0.07 to 0.21 mm) in the fully digital group and 0.18 ± 0.13 mm (range -0.10 to 0.60 mm; 95% CI: 0.09 to 0.26 mm). The difference was not statistically significant (-0.04 ± 0.19 mm; range -0.50 to 0.30 mm; 95% CI: -0.16 to 0.08 mm; P = 0.294). CONCLUSIONS With the limitations of the present trial, implant rehabilitations planned using intraoral digital impressions showed similar results compared to conventional impression and scan model. Digital impression may be a viable option for the rehabilitation of partial edentulous patients when computer-guided template-assisted implant placement is used.
Collapse
|
Randomized Controlled Trial |
6 |
|
12
|
Sacchetto L, Berzaghi A, Martinolli M, Bortolini S. Timing terapeutico e concetto di “urgenza” ortodontica. Linee guida e revisione della letteratura. DENTAL CADMOS 2011. [DOI: 10.1016/j.cadmos.2011.02.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
|
14 |
|
13
|
Martinolli M, Bortolini S, Natali A, Pereira LJ, Castelo PM, Rodrigues Garcia RCM, Gonçalves TMSV. Cover Image. J Oral Rehabil 2019. [DOI: 10.1111/joor.12828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
|
6 |
|