1
|
Assessing brain integrity in patients with long-term and well-functioning metal-based hip implants. J Orthop Res 2024; 42:1292-1302. [PMID: 38235918 DOI: 10.1002/jor.25785] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Revised: 12/08/2023] [Accepted: 01/03/2024] [Indexed: 01/19/2024]
Abstract
Production of metal debris from implant wear and corrosion processes is now a well understood occurrence following hip arthroplasty. Evidence has shown that metal ions can enter the bloodstream and travel to distant organs including the brain, and in extreme cases, can induce sensorial and neurological diseases. Our objective was tosimultaneously analyze brain anatomy and physiology in patients with long-term and well-functioning implants. Included were subjects who had received total hip or hip resurfacing arthroplastywith an implantation time of a minimum of 7 years (n = 28) and age- and sex-matched controls (n = 32). Blood samples were obtained to measure ion concentrations of cobalt and chromium, and the Montreal Cognitive Assessment was performed. 3T MRI brain scans were completed with an MPRAGE sequence for ROI segmentation and multiecho gradient echo sequences to generate QSM and R2* maps. Mean QSM and R2* values were recorded for five deep brain and four middle and cortical brain structures on both hemispheres: pallidum, putamen, caudate, amygdala, hippocampus, anterior cingulate, inferior temporal, and cerebellum. No differences in QSM or R2* or cognition scores were found between both groups (p > 0.6654). No correlation was found between susceptibility and blood ion levels for cobalt or chromium in any region of the brain. No correlation was found between blood ion levels and cognition scores. Clinical significance: Results suggest that metal ions released by long-term and well-functioning implants do not affect brain integrity.
Collapse
|
2
|
Lateral Subvastus Lateralis versus Medial Parapatellar Approach for Total Knee Arthroplasty: Patient Outcomes and Kinematics Analysis. J Knee Surg 2024; 37:523-529. [PMID: 37992725 DOI: 10.1055/s-0043-1777077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2023]
Abstract
The conventional approach for total knee arthroplasty (TKA) is a medial parapatellar approach (MPA). We aimed to study patient outcomes and kinematics with a quadriceps sparing lateral subvastus lateralis approach (SLA). Patients with neutral/varus alignment undergoing primary TKA were consented to undergo the SLA. At 1-year postoperative, patients underwent radiostereometric analysis. Patients were administered the Short Form 12 (SF-12), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and Knee Society Score (KSS). Kinematics and outcome data were compared to a group undergoing TKA via conventional MPA. Fourteen patients underwent TKA via SLA with a mean age 71.5 ± 8.0 and mean body mass index (BMI) 31.0 ± 4.5. The MPA group had 13 patients with mean age 63.4 ± 5.5 (p = 0.006) and mean BMI 31.2 ± 4.6 (p = 0.95). The SLA resulted in a significantly more posterior medial contact point at 0 (p = 0.011), 20 (p = 0.020), and 40 (p = 0.039) degrees of flexion. There was no significant difference in medial contact point from 60 to 120 degrees, lateral contact point at any degree of flexion, or axial rotation. There was no difference in improvement in postoperative WOMAC, SF-12, KSS function, and total KSS knee scores between groups. The MPA group had a significantly greater improvement in KSS knee scores at 3 months (p < 0.001), 1 year (p = 0.003), and 2 years (p = 0.017). The SLA resulted in increased medial femoral rollback early in flexion. Although both approaches resulted in improved postoperative outcomes, the MPA group showed significantly greater improvements in KSS knee scores at 3 months, 1 year, and 2 years. Further studies are required to identify any benefits that the SLA may offer. LEVEL OF EVIDENCE: Therapeutic Level II.
Collapse
|
3
|
Quantification of trunnion damage in a series of intact total hip arthroplasty femoral stems previously identified to be at risk of catastrophic failure. Hip Int 2024; 34:363-371. [PMID: 37786293 DOI: 10.1177/11207000231199941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
BACKGROUND Corrosion at the head-neck junction of femoral stems is a rare complication of total hip arthroplasty (THA) with manifestations ranging from subclinical wear to failure. Prior studies have identified a single femoral component design with an increased propensity for catastrophic trunnion failure. The purpose of the present study was to quantify trunnion damage of this femoral component retrieved from patients undergoing revision THA for non-trunnionosis indications. METHODS 24 femoral components from a single manufacturer were identified for study inclusion. Each prosthesis underwent stereomicroscopic inspection. Corrosion and fretting scores were assigned per the Goldberg criteria to quadrants of the trunnion. Material loss was calculated based on cone angles across trunnion quadrants. This was carried out using a coordinate measuring machine that digitised each trunnion surface. Stems were compared to a series of femoral stems with the same trunnion design. RESULTS 20 of the 24 (83%) trunnions demonstrated corrosion, all 24 trunnions demonstrated fretting. Corrosion scores did not statistically differ with respect to trunnion zone (p = 0.53), while fretting scores were higher in the inferior compared to the superior zones (p < 0.001). There was no significant difference in cone angles assessing material loss between stems (p = 0.25). CONCLUSIONS Evidence of trunnion damage was observed in each stem retrieved for non-trunnionosis revision. Fretting occurred more frequently about the inferior quadrants. However, digitised trunnion shapes were similar between compared stems exhibiting no material loss. Therefore, it is possible that previous reports of trunnion failures for this implant are not a systemic issue, and that further investigation is required.
Collapse
|
4
|
Phantom validation of a novel RSA-based impingement metric to assess component-on-component impingement risk. Proc Inst Mech Eng H 2024; 238:483-487. [PMID: 38519832 PMCID: PMC11083746 DOI: 10.1177/09544119241238950] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/25/2024]
Abstract
Component-on-component impingement in total hip arthroplasty may lead to post-operative complications including dislocation. Despite numerous clinical studies focusing on reducing this risk, assessment methods remain limited to qualitative radiography, finite element analysis, and cadaver studies. There is a need for more precise measurements of impingement in the research setting. We aimed to validate a novel RSA-based impingement metric to measure component-on-component impingement in vivo. A phantom experiment of a standard metal-on-polyethylene total hip system was performed. RSA examinations were performed as typical for a traditional weight-bearing RSA exam for large joints. The phantom was placed in 10 possible impinged positions and one neutral position. Double exposure radiographs were taken to measure repeatability. The closest distance between the skirt of the head and the inner circumference of the acetabular cup liner was measured to assess impingement risk. Distances between the closest point of the hood to the edge of the cup in 10 impinged positions ranged from 0.05 to 1.03 mm, with the average being 0.67 mm. In the neutral position, the distance measured is 11.02 mm. Excellent repeatability was observed, with a standard deviation of 0.03 mm with an r value of 0.09. A validated RSA-based risk metric was established to evaluate in vivo hip impingement. A 1 mm threshold may be proposed to define impingement where distances approaching 1.00 mm are at a greater risk of impingement. This simplified metric holds promise for upcoming clinical studies on component-on-component impingement.
Collapse
|
5
|
CORR Insights®: What Is the Long-term Wear of a 5-Mrad Highly Crosslinked Polyethylene Liner? A 14-year RSA Study. Clin Orthop Relat Res 2024:00003086-990000000-01580. [PMID: 38686997 DOI: 10.1097/corr.0000000000003086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Accepted: 03/25/2024] [Indexed: 05/02/2024]
|
6
|
The Microbial Revolution in the World of Joint Replacement Surgery. JB JS Open Access 2024; 9:e23.00153. [PMID: 38638595 PMCID: PMC11023614 DOI: 10.2106/jbjs.oa.23.00153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/20/2024] Open
Abstract
Background The prevalence of revision surgery due to aseptic loosening and periprosthetic joint infection (PJI) following total hip and knee arthroplasty is growing. Strategies to prevent the need for revision surgery and its associated health-care costs and patient morbidity are needed. Therapies that modulate the gut microbiota to influence bone health and systemic inflammation are a novel area of research. Methods A literature review of preclinical and clinical peer-reviewed articles relating to the role of the gut microbiota in bone health and PJI was performed. Results There is evidence that the gut microbiota plays a role in maintaining bone mineral density, which can contribute to osseointegration, osteolysis, aseptic loosening, and periprosthetic fractures. Similarly, the gut microbiota influences gut permeability and the potential for bacterial translocation to the bloodstream, increasing susceptibility to PJI. Conclusions Emerging evidence supports the role of the gut microbiota in the development of complications such as aseptic loosening and PJI after total hip or knee arthroplasty. There is a potential for microbial therapies such as probiotics or fecal microbial transplantation to moderate the risk of developing these complications. However, further investigation is required. Clinical Relevance Modulation of the gut microbiota may influence patient outcomes following total joint arthroplasty.
Collapse
|
7
|
Correction to: Multimodal positron emission tomography (PET) imaging in non-oncologic musculoskeletal radiology. Skeletal Radiol 2024:10.1007/s00256-024-04667-7. [PMID: 38557699 DOI: 10.1007/s00256-024-04667-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
|
8
|
Effect of Surgical Technique, Implant Design, and Time of Examination on Contact Kinematics: A Study of Bicruciate-Stabilized and Posterior-Stabilized Total Knee Arthroplasty. J Arthroplasty 2024:S0883-5403(24)00256-0. [PMID: 38522799 DOI: 10.1016/j.arth.2024.03.040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 03/14/2024] [Accepted: 03/15/2024] [Indexed: 03/26/2024] Open
Abstract
BACKGROUND Bicruciate-stabilized (BCS) total knee arthroplasty (TKA) designs attempt to approximate natural knee mechanics. Multiple surgical techniques, including gap balancing (GB) and measured resection (MR), have been developed to provide optimal implant positioning and soft-tissue balance. The goal of this study was to determine the effect of surgical technique on BCS TKA contact kinematics. Secondary goals included investigating the change of kinematics over time and comparing BCS TKA kinematics to a posterior-stabilized (PS) design. METHODS The study included the BCS-GB, BCS-MR, and PS-MR groups. The BCS-GB and BCS-MR groups underwent weight-bearing radiostereometric analysis for multiple knee flexion angles at 3 months and 1 year postoperatively, whereas the PS-MR group was imaged at 1 year postoperatively. The medial and lateral contact kinematics were determined from implant poses. RESULTS There were no differences in BCS TKA kinematics between the GB and MR techniques. There were differences in the mid-flexion ranges when comparing the 3-month and 1-year kinematics of the BCS design; however, they were less than 1.5 mm. Differences existed between the kinematics of the BCS and PS designs at all flexion angles for the medial condyle (P < .0006) and at 0° of flexion on the lateral condyle (P < .0001). CONCLUSIONS Contact kinematics for a BCS design were similar for both surgical techniques, suggesting both are appropriate for this design. Small, likely clinically insignificant differences were found between 3-month and 1-year kinematics. The BCS TKA kinematics differed from the PS design; however, it is unclear whether these differences improve clinical outcomes.
Collapse
|
9
|
Multimodal positron emission tomography (PET) imaging in non-oncologic musculoskeletal radiology. Skeletal Radiol 2024:10.1007/s00256-024-04640-4. [PMID: 38492029 DOI: 10.1007/s00256-024-04640-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 02/27/2024] [Accepted: 02/28/2024] [Indexed: 03/18/2024]
Abstract
Musculoskeletal (MSK) disorders are associated with large impacts on patient's pain and quality of life. Conventional morphological imaging of tissue structure is limited in its ability to detect pain generators, early MSK disease, and rapidly assess treatment efficacy. Positron emission tomography (PET), which offers unique capabilities to evaluate molecular and metabolic processes, can provide novel information about early pathophysiologic changes that occur before structural or even microstructural changes can be detected. This sensitivity not only makes it a powerful tool for detection and characterization of disease, but also a tool able to rapidly assess the efficacy of therapies. These benefits have garnered more attention to PET imaging of MSK disorders in recent years. In this narrative review, we discuss several applications of multimodal PET imaging in non-oncologic MSK diseases including arthritis, osteoporosis, and sources of pain and inflammation. We also describe technical considerations and recent advancements in technology and radiotracers as well as areas of emerging interest for future applications of multimodal PET imaging of MSK conditions. Overall, we present evidence that the incorporation of PET through multimodal imaging offers an exciting addition to the field of MSK radiology and will likely prove valuable in the transition to an era of precision medicine.
Collapse
|
10
|
A multimodal assessment of cementless tibial baseplate fixation using radiography, radiostereometric analysis, and magnetic resonance imaging. J Orthop Res 2024; 42:100-108. [PMID: 37442642 DOI: 10.1002/jor.25662] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 05/22/2023] [Accepted: 07/11/2023] [Indexed: 07/15/2023]
Abstract
Fixation in cementless total knee arthroplasty is provided by osseous integration. Radiography, radiostereometric analysis (RSA), and magnetic resonance imaging (MRI) were used simultaneously to investigate fixation. Relationships between RSA-measured implant micromotions and MRI-evaluated osseous integration at the component-bone interface were assessed in 10 patients up to 6 months postoperation. Supine MRI (using multispectral imaging sequences) and RSA exams were performed to evaluate osseous integration and measure longitudinal migration, respectively. Inducible displacement was measured from standing RSA exams. Radiolucent lines were detected on conventional radiographs. Of 10 patients, 6 had fibrous membranes detected on MRI. No fluid or osteolytic interfaces were found, and no components were scored loose. Of 10 patients, 6 had radiolucent lines detected. Average maximum total point motion (MTPM) for longitudinal migration at 6 months was 0.816 mm (range 0.344-1.462 mm). Average MTPM for inducible displacement at 6 months was 1.083 mm (range 0.553-1.780 mm). Fictive points located in fibrous-classified baseplate quadrants had greater longitudinal migration than fictive points located in baseplate quadrants with normal interfaces at 2 weeks (p = 0.031), 6 weeks (p = 0.046), and 3 months (p = 0.047), and greater inducible displacements at 3 months (p = 0.011) and 6 months (p = 0.045). Greater early micromotion may be associated with the presence of fibrous membranes at the component-bone interface. Clinical significance: This multimodal imaging study contributes knowledge of the fixation of modern cementless TKA, supporting the notion that osseous integration is important for optimal implant fixation.
Collapse
|
11
|
Gap patterns and radiographic follow-up of newer-generation cementless total knee arthroplasty designs. Can J Surg 2024; 67:E85-E90. [PMID: 38453351 PMCID: PMC10927283 DOI: 10.1503/cjs.008223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/01/2023] [Indexed: 03/09/2024] Open
Abstract
BACKGROUND Interest in cementless total knee arthroplasty (TKA) has increased with advancement of biomaterials and implant design and associated improved longevity. We sought to evaluate the gap patterns and radiolucent zones radiographically for 2 newer-generation cementless TKA designs. METHODS We retrospectively reviewed our single-institution database between January 2017 and December 2019. We identified patients with a porous keeled tibia base-plate with 4-bullet cruciform spikes and peri-apatite coated femoral component (study group 1) and patients who received a cementless porous coated femoral component and rotating platform tibia baseplate with 4 peripheral porous coated pegs around a central cone (study group 2). We identified gap patterns at 6 weeks and at 1 year or more postoperatively on radiographs, noting indications for reoperation. RESULTS We identified 228 patients in study group 1 and 41 patients in study group 2. At 1-year follow-up, we found evidence of resolved femoral gaps in 52 (72.2%) of 72 patients in study group 1 and 10 (58.8%) of 17 patients in study group 2 (p = 0.124). We identified 27 (84.3%) of 32 patients in study group 1 and 7 (70.0%) of 10 patients in study group 2 with resolved tibia gaps (p = 0.313). After 1 year, there were significantly more Zone 3a femoral zonal radiolucent gaps (p = 0.001) and Zone 8 tibia zonal radiolucent gaps (p = 0.002) in study group 2 than in study group 1. There were 4 reoperations for study group 1 and 0 reoperations for study group 2. CONCLUSION The modern cementless TKA systems have varied gap patterns in postoperative radiographs, which may be attributed to the implant design. Most radiolucent gaps resolve radiographically on follow-up.
Collapse
|
12
|
Acetabular cup fixation with and without screws following primary total hip arthroplasty: migration evaluated by radiostereometric analysis. Hip Int 2024; 34:42-48. [PMID: 37016808 PMCID: PMC10787387 DOI: 10.1177/11207000231164711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Accepted: 02/25/2023] [Indexed: 04/06/2023]
Abstract
BACKGROUND Early cup migration after total hip arthroplasty (THA) is correlated to late revision due to aseptic loosening. However, the use of screws for increased cup stability remains unclear and debated. The purpose of this study is to assess acetabular migration between cups fixated with and without the use of screws. METHODS Patients underwent primary THA using either a direct anterior (DA) or a direct lateral (DL) approach. The DA surgeon routinely supplemented cup fixation with 1 or 2 screws while the DL surgeon used no screws. At 7 follow-up visits up to 2 years post operation, patients underwent radiostereometric analysis (RSA) imaging for implant migration tracking. The primary outcome was defined as proximal cup migration measured with model-based RSA. RESULTS 68 patients were assessed up to 2 years post operation, n = 43 received screws and n = 25 did not. The use of screws had a significant effect on cup migration (p = 0.018). From 2 weeks to 2 years post operation, the total mean migration was 0.403 ± 0.681 mm and 0.129 ± 0.272 mm (p = 0.319) for cups with and without screws, respectively. The number of screws used also had a significant impact, with cups fixated with 1 screw migrating more than cups fixated with 2 (p = 0.013, mean difference 0.712 mm). CONCLUSIONS Acetabular cups fixated with only 1 screw resulted in greater migration than cups with no screws or 2 screws, though the mean magnitude was well under the 1.0 mm threshold for unacceptable migration. However, 3 of the 24 patients who received only 1 screw exceeded the 1.0 mm threshold for unacceptable migration. Ultimately, the results of this study show that the use of 2 screws to supplement cup fixation can provide good implant stability that is equivalent to a secure press-fit component with no screws.Clinical trial registration: ClinicalTrials.gov (NCT03558217).
Collapse
|
13
|
A convolutional neural network for high throughput screening of femoral stem taper corrosion. Proc Inst Mech Eng H 2023:9544119231177834. [PMID: 37300244 DOI: 10.1177/09544119231177834] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Corrosion at the modular head-neck taper interface of total and hemiarthroplasty hip implants (trunnionosis) is a cause of implant failure and clinical concern. The Goldberg corrosion scoring method is considered the gold standard for observing trunnionosis, but it is labor-intensive to perform. This limits the quantity of implants retrieval studies typically analyze. Machine learning, particularly convolutional neural networks, have been used in various medical imaging applications and corrosion detection applications to help reduce repetitive and tedious image identification tasks. 725 retrieved modular femoral stem arthroplasty devices had their trunnion imaged in four positions and scored by an observer. A convolutional neural network was designed and trained from scratch using the images. There were four classes, each representing one of the established Goldberg corrosion classes. The composition of the classes were as follows: class 1 (n = 1228), class 2 (n = 1225), class 3 (n = 335), and class 4 (n = 102). The convolutional neural network utilized a single convolutional layer and RGB coloring. The convolutional neural network was able to distinguish no and mild corrosion (classes 1 and 2) from moderate and severe corrosion (classes 3 and 4) with an accuracy of 98.32%, a class 1 and 2 sensitivity of 0.9881, a class 3 and 4 sensitivity of 0.9556 and an area under the curve of 0.9740. This convolutional neural network may be used as a screening tool to identify retrieved modular hip arthroplasty device trunnions for further study and the presence of moderate and severe corrosion with high reliability, reducing the burden on skilled observers.
Collapse
|
14
|
Axial and sagittal rotation of cementless tibial baseplates occurs in bone under joint loading. J Arthroplasty 2023; 38:1166-1171. [PMID: 36893992 DOI: 10.1016/j.arth.2023.03.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 02/27/2023] [Accepted: 03/01/2023] [Indexed: 03/11/2023] Open
Abstract
INTRODUCTION There has been a recent increase in the use of cementless fixation for primary total knee arthroplasty (TKA). While the early results of contemporary cementless implants are promising, understanding the behavior of cementless tibial baseplates under loading remains an ongoing interest. The objective of this study was to identify the pattern of displacement that occurred under loading for a single cementless tibial baseplate design at one-year post-operation for stable and continuously migrating implants. METHODS There were 28 subjects from a previous trial of a pegged highly porous cementless tibial baseplate evaluated. Subjects underwent supine radiostereometric exams from two weeks through one year after surgery. At one year, subjects also underwent a standing radiostereometric exam. Fictive points on the tibial baseplate model were used to relate translations to anatomical locations. Migration over time was calculated to determine if subjects displayed stable or continuous migration. The magnitude of inducible displacement between the supine and standing exams was calculated. RESULTS Inducible displacement patterns were similar between stable and continuously migrating tibial baseplates. Displacements were greatest in the anterior-posterior axis followed by the lateral-medial axis. Correlation of displacements between adjacent fictive points in these axes indicated an axial rotation of the baseplate occurred under loading (r2 = 0.689-0.977, P< 0.001). Less displacement occurred in the superior-inferior axis and correlations indicated an anterior-posterior tilt of the baseplate occurred under loading (r2 = 0.178-0.226, P = 0.009-0.023). DISCUSSION From supine to standing position the predominant pattern of displacement for this cementless tibial baseplate was axial rotation, with some subjects also displaying an anterior-posterior tilt.
Collapse
|
15
|
What Patient and Implant Factors Affect Trunnionosis Severity? An Implant Retrieval Analysis of 664 Femoral Stems. J Arthroplasty 2023; 38:376-382. [PMID: 36084756 DOI: 10.1016/j.arth.2022.08.023] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 08/11/2022] [Accepted: 08/12/2022] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND Corrosion at the modular head-neck taper interface of total and hemiarthroplasty hip implants (trunnionosis) is a cause of implant failure and thus a clinical concern. Patient and device factors contributing to the occurrence of trunnionosis have been investigated in prior implant retrieval studies but generally with limited sample sizes and a narrow range of models. The purpose of the present investigation was to determine which patient and device factors were associated with corrosion damage on the femoral stem taper across a large collection of different implant models retrieved following revision hip arthroplasty. METHODS A retrieval study of 664 hip arthroplasty modular stem components was performed. Patient and device information was collected. Trunnions were imaged under digital microscopy and scored for corrosion damage using a scaling system. Damage was related to patient and device factors using regression analyses. RESULTS Greater duration of implantation (P = .005) and larger head size (P < .001) were associated with an elevated corrosion class. Older age at index surgery (P = .035), stainless steel stem material (P = .022), indication for revision as bone or periprosthetic fracture (P = .017), and infection (P = .018) and certain larger taper geometries were associated with a decreased corrosion class. CONCLUSION Factors identified as contributing to a higher or lower risk of more severe corrosion are consistent with most prior smaller retrieval studies. Surgeons should be aware of these risk factors when selecting implants for their patients and when diagnosing trunnionosis in symptomatic hip arthroplasty patients.
Collapse
|
16
|
Validation of a machine learning technique for segmentation and pose estimation in single plane fluoroscopy. J Orthop Res 2023. [PMID: 36691875 DOI: 10.1002/jor.25518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Revised: 11/18/2022] [Accepted: 01/19/2023] [Indexed: 01/25/2023]
Abstract
Kinematics of total knee replacements (TKR) play an important role in assessing the success of a procedure and would be a valuable addition to clinical practice; however, measuring TKR kinematics is time consuming and labour intensive. Recently, an automatic single-plane fluoroscopic method utilizing machine learning has been developed to facilitate a quick and simple process for measuring TKR kinematics. This study aimed to validate the new automatic single-plane technique using biplanar radiostereometric analysis (RSA) as the gold standard. Twenty-four knees were imaged at various angles of flexion in a dedicated RSA lab and 113 image pairs were obtained. Only the lateral RSA images were used for the automatic single-plane technique to simulate single-plane fluoroscopy. Two networks helped automate the kinematics measurement process, one segmented implant components and the other generated an initial pose estimate for the optimization algorithm. Kinematics obtained via the automatic single plane and manual biplane techniques were compared using root-mean-square error and Bland-Altman plots. Two observers measured the kinematics using the automated technique and results were compared with assess reproducibility. Root-mean-square errors were 0.8 mm for anterior-posterior translation, 0.5 mm for superior-inferior translation, 2.6 mm for medial-lateral translation, 1.0° for flexion-extension, 1.2° for abduction-adduction, and 1.7° for internal-external rotation. Reproducibility, reported as root-mean-square errors between operator measurements, was submillimeter for in-plane translations and below 2° for all rotations. Clinical Significance: The advantages of the automated single plane technique should aid in the kinematic measurement process and help researchers and clinicians perform TKR kinematic analyses.
Collapse
|
17
|
The impact of free-radical stabilization techniques on in vivo subsurface mechanical properties in highly cross-linked polyethylene acetabular liners. J Orthop Res 2023. [PMID: 36601654 DOI: 10.1002/jor.25502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2022] [Revised: 11/14/2022] [Accepted: 12/07/2022] [Indexed: 01/06/2023]
Abstract
Highly cross-linked polyethylene (HXLPE) for total hip arthroplasty was developed to improve wear resistance in vivo and associated complications in comparison to ultrahigh molecular weight polyethylene. This material typically goes through various free-radical stabilization techniques by remelting, single-annealing, or sequentially annealing the polyethylene to improve in vivo oxidation and wear properties. The purpose of this study is to determine if there is evidence of subsurface microhardness changes in retrieved HXLPE liner at the rim and articular subsurface after extended in vivo time that could be associated with oxidation and its effects on mechanical properties and implant integrity. Retrieved HXLPE liners were chosen based on peak subsurface Fourier transform infrared spectroscopy oxidation values. Each was mechanically tested for subsurface microhardness at both the rim and articular surface using a validated microindentation technique. Rim testing demonstrated a decrease in mechanical integrity that corresponded to higher subsurface oxidation values regardless of the free-radical stabilization technique. At the articular surface, a decrease in mechanical integrity was observed near the surface corresponding to peak oxidation and Vicker's hardness, which decreased with increasing depths. This was found in all groups, with the exception of the single-annealed liners, which demonstrated decreased mechanical integrity trends at greater depths between 1.0 and 2.0 mm. Our results suggest that subsurface mechanical properties do change in vivo for certain implants. Though it is likely that the mechanical failures are multifactorial, we have shown that mechanical property degradation of HXLPE liners does occur with long-term in vivo exposure and should be considered a possible risk factor.
Collapse
|
18
|
A Ten-Year Radiostereometric Analysis of Polyethylene Wear Between Oxidized Zirconium and Cobalt Chrome Articulations in Total Hip Arthroplasty. J Arthroplasty 2022; 37:S692-S696. [PMID: 35245689 DOI: 10.1016/j.arth.2022.02.099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Revised: 02/14/2022] [Accepted: 02/23/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Oxidized zirconium (OxZi) femoral heads combine the decreased abrasive properties of ceramics with the toughness of metal alloys to lower wear and increase the durability of total hip arthroplasty. The purpose of this study was to compare the 10-year polyethylene wear rates between OxZi/XLPE and cobalt chrome (CoCr)/XLPE articulations. METHODS A radiostereometric analysis (RSA) was performed on two cohorts of 23 patients who underwent total hip arthroplasty using either OxZi/XLPE or CoCr/XLPE at a minimum of 10-year follow-up. Cohorts were matched for age, gender, body mass index (BMI), and diagnosis. Polyethylene wear was measured using RSA to determine total and steady-state wear rates for both cohorts. Preoperative and postoperative patient-reported outcome measures (SF12, HHS, and Western Ontario and McMaster Universities Arthritis Index scores) were compared. RESULTS The mean total head penetration rate was found to be statistically different between the entire cohorts (OxZi 0.048 ± 0.021 mm/y, CoCr 0.035 ± 0.017 mm/y, P = .02) but not when 28-mm heads only (OxZi 0.045 ± 0.016 mm/y, CoCr 0.034 ± 0.017 mm/y, P = .066) were directly compared. The mean steady-state wear rate was not significantly different between the entire cohorts (OxZi 0.031 ± 0.021 mm/y, CoCr 0.024 ± 0.019 mm/y, P = .24) or 28-mm head cohorts (OxZi 0.028 ± 0.019 mm/y, CoCr 0.024 ± 0.019 mm/y, P = .574). Outcome measures showed no statistical difference except for the Harris Hip Score where the OxZi cohort demonstrated higher median scores. CONCLUSION Using RSA to evaluate the 10-year in-vivo head penetration, there was no statistically significant difference in steady-state wear rates between OxZi and CoCr articulations. Both bearing combinations demonstrated wear rates well below the threshold for osteolysis.
Collapse
|
19
|
Femoral stem migration after direct lateral and direct anterior total hip arthroplasty: a prospective cohort study. Can J Surg 2022; 65:E487-E495. [PMID: 35926882 PMCID: PMC9363127 DOI: 10.1503/cjs.013221] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/04/2021] [Indexed: 11/26/2022] Open
Abstract
Background: The direct lateral (DL) approach to total hip arthroplasty is more commonly used than the newer direct anterior (DA) approach. Both approaches use collared or collarless femoral stems. We sought to assess implant stability of stem designs implanted with the DL approach and compare outcomes from this cohort with those of a previously reported cohort of patients who underwent arthroplasty with a DA approach. We also sought to determine if early recovery influences differences in migration. Methods: Patients underwent total hip arthroplasty using the DL or the DA approach and were randomized to receive either a collared or collarless, cementless femoral stem. On the day of surgery and at 6 follow-up visits through to 1 year, patients underwent supine radiostereometric imaging to track implant migration. At follow-up visits, patients performed an instrumented walking test to assess their functional ability and logged an average daily step count to assess their activity levels. We assessed whether patient function and activity were correlated with migration. Results: Stem design did not have a significant effect on migration for the DL group (p = 0.894). Compared with the DA group, the DL group migrated significantly less for both collared (p = 0.031) and collarless (p = 0.002) stems. Migration was not correlated with function or activity at any time point (p > 0.05). Conclusion: Most implant migration occurred from the day of surgery to 2 weeks after the operation and stabilized thereafter, suggesting adequate fixation and a low risk for aseptic loosening in both patient groups.
Collapse
|
20
|
Patient and Implant Performance of Satisfied and Dissatisfied Total Knee Arthroplasty Patients. J Arthroplasty 2022; 37:S98-S104. [PMID: 35569919 DOI: 10.1016/j.arth.2021.10.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Revised: 09/30/2021] [Accepted: 10/26/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Implant migration and altered kinematics have been thought to impact patient-reported outcome measures (PROMs) and postoperative patient satisfaction. In this study comparing satisfied and dissatisfied total knee arthroplasty (TKA) patients, we hypothesized that dissatisfied patients will have greater continuous implant migration and that there will be differences in joint kinematics, objective functional measurements, and PROMs between satisfied and dissatisfied patients. METHODS The Knee Society Score Satisfaction Subsection questions regarding satisfaction with function were used at least 6 months postoperation to split 50 patients into satisfied and dissatisfied groups. Patients underwent radiostereometric analysis to evaluate migration and kinematics. A wearable sensor system obtained objective measurements of patient function during timed up and go tests. PROMs were recorded preoperation and postoperation. RESULTS No statistically significant differences were found in migration between satisfied and dissatisfied groups. Statistical kinematic differences existed in lateral anteroposterior contact location at 20° and 40° of flexion at 1 year, where the dissatisfied group had more anteriorly located lateral contact. No statistically significant differences were present in objective functional measurements. Satisfied and dissatisfied groups had differing PROMs at 4 timepoints or greater for each questionnaire. CONCLUSIONS No differences were found in tibial component migration or objectively measured function between satisfied and dissatisfied patients. Functionally dissatisfied patients had more anteriorly positioned contact on the lateral condyle in early flexion and reported more pain and unmet expectations. These findings suggest that improving the functional satisfaction of TKA requires restoration of kinematics in early flexion and management of patient's pain and expectations.
Collapse
|
21
|
Bony increased-offset reverse shoulder arthroplasty vs. metal augments in reverse shoulder arthroplasty: a prospective, randomized clinical trial with 2-year follow-up. J Shoulder Elbow Surg 2022; 31:591-600. [PMID: 34968693 DOI: 10.1016/j.jse.2021.11.007] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 11/10/2021] [Accepted: 11/16/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND Reverse shoulder arthroplasty (RSA) is rapidly being adopted as the standard procedure for a growing number of shoulder pathologies. Lateralization of the glenoid component is known to reduce the incidence of scapular notching and possibly improve postoperative range of motion. A number of methods are used for glenoid component lateralization, including bony increased-offset reverse shoulder arthroplasty (BIO-RSA) and porous metal-augmented baseplates. Presently, there exists little comparative literature on bone vs. metal lateralization. Therefore, the purpose of this study was to compare BIO-RSA to metal-augmented glenoid baseplates by assessing clinical outcomes and baseplate migration using model-based radiostereometric analysis. METHODS A power analysis indicated 40 patients would be required for this radiostereometric study. Therefore, 41 shoulders were prospectively randomized to receive either glenoid bone grafting (BIO-RSA) or a porous metal-augmented wedge-shaped titanium baseplate for primary reverse shoulder arthroplasty. At the time of primary surgery, all patients also underwent implantation of 8 tantalum marker beads in the glenoid and coracoid. Following surgery, participants were imaged using a calibrated, stereo radiographic technique. Radiographs were acquired at 6 weeks (baseline), 3 months, 6 months, 1 year, and 2 years postoperatively. Migration of the prosthesis was compared between bone and metal lateralization groups at each time point using a mixed effects model with Bonferroni test for multiple comparisons. Outcome measures were acquired preoperatively and 2 years postoperatively. RESULTS No significant differences were observed along any translation or rotation axis at any time point for either glenoid fixation group (P ≥ .175). Mean total glenoid component translation (± standard deviation) 2 years postoperatively was 0.4 ± 0.2 mm and 0.5 ± 0.3 mm for BIO-RSA and metal-augmented baseplates, respectively (P = .784). No significant differences were observed between groups in active range of motion; pain; American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form score; Simple Shoulder Test score; Disabilities of the Arm, Shoulder, and Hand score; Constant Shoulder score; or Subjective Shoulder Value (P ≥ .117), with the exception of increased active external rotation in the BIO-RSA cohort (P = .036). CONCLUSION This randomized clinical trial assessed reverse shoulder arthroplasty glenoid component migration using model-based radiostereometric analysis. At 2-year follow-up, our results indicate both BIO-RSA and porous metal wedge augmented baseplates provide stable initial fixation, which is maintained at 2 years' follow-up, with no substantial differences in clinical outcomes.
Collapse
|
22
|
Are short press-fit stems comparable to standard-length cemented stems in reverse shoulder arthroplasty? A prospective, randomized clinical trial. J Shoulder Elbow Surg 2022; 31:580-590. [PMID: 34968694 DOI: 10.1016/j.jse.2021.11.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Revised: 11/10/2021] [Accepted: 11/16/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND The literature comparing humeral implants in reverse shoulder arthroplasty is sparse. With minimal supporting literature, there has been a trend away from standard-length cemented humeral implants to press-fit stems and, recently, to shorter-stem implants. It is known that early implant migration, within the first 2 years postoperatively, is predictive of later implant loosening and possible revision surgery. Therefore, the purpose of this study was to compare clinical outcomes and implant migration between cemented standard-length humeral stems and press-fit short stems using model-based radiostereometric analysis. METHODS After a power analysis, 41 shoulders were prospectively randomized to receive either a cemented standard-length or press-fit short humeral stem for primary reverse shoulder arthroplasty between July 2017 and June 2019. Following surgery, participants were imaged with stereo radiographs acquired at 6 weeks (baseline), 3 months, 6 months, 1 year, and 2 years. Migration of the humeral stem at each time point was compared with baseline, with differences in migration between cohorts assessed using a mixed-effects model with the Bonferroni test for multiple comparisons. Patient-reported outcome measures (Subjective Shoulder Value; American Shoulder and Elbow Surgeons shoulder score; Simple Shoulder Test score; Disabilities of the Arm, Shoulder and Hand score; and Constant score) were also compared. RESULTS At 6 months (P = .025), 1 year (P = .004), and 2 years (P = .001) postoperatively, press-fit short stems migrated significantly more than cemented stems along the superior-inferior translation axis; in addition, they showed greater total translation at 2 years (P = .003). Mean total translation (± standard deviation) at 2 years was 0.4 ± 0.2 mm and 1.0 ± 1.1 mm for the cemented and press-fit cohorts, respectively. Mean migration between the 1- and 2-year time points was minimal for both stem fixation groups along all axes (<0.1 mm and 0.6°). There was no difference in active range of motion, pain, or validated outcome measures between the cohorts at 2 years (P ≥ .170). CONCLUSION This randomized clinical trial shows that press-fit short humeral stems subside substantially more than standard-length cemented stems but ultimately achieve stability from 1 year through 2 years. Conversely, no significant differences were observed in clinical outcomes between cohorts.
Collapse
|
23
|
Migration and Inducible Displacement of the Bicruciate-Stabilized Total Knee Arthroplasty: A Randomized Controlled Trial of Gap Balancing and Measured Resection Techniques. J Arthroplasty 2022; 37:252-258. [PMID: 34710566 DOI: 10.1016/j.arth.2021.10.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Revised: 10/13/2021] [Accepted: 10/15/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND The goal of this study is to investigate the migration and inducible displacement of a bicruciate-stabilized (BCS) total knee arthroplasty implanted using gap balancing (GB) or measured resection (MR) surgical techniques. We hypothesized equal migration and displacement between the techniques. METHODS The study is a single-blinded, prospective, randomized controlled trial, with allocation of 71 patients to either GB or MR groups. Fifteen patients were withdrawn, resulting in 31 patients in the GB group and 25 in the MR group. Patients received the JOURNEY II™ BCS implant. Migration and inducible displacement were evaluated using radiostereometric analysis and patient examinations were performed at a 2-week baseline, and at 6 weeks, 3 months, 6 months, 1 year, and 2 years postoperation. RESULTS No differences (P > .05) existed between GB and MR groups for any measurement of tibial or femoral migration. Both groups had tibial migrations below 0.5 mm from baseline to 6 months, and below 0.2 mm from both 6 months to 1 year and 1-2 years postoperation. No differences (P > .05) were found between GB and MR groups for inducible displacement. CONCLUSION No differences were found in implant migration or inducible displacement between GB and MR groups. The BCS implant can be expected to have migration risks on par with industry standards and both surgical techniques are safe and effective options for implantation of this implant design.
Collapse
|
24
|
Does surgical approach affect patient outcomes of total knee arthroplasty? Can J Surg 2021; 64:E521-E526. [PMID: 34598930 PMCID: PMC8526133 DOI: 10.1503/cjs.010920] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/05/2020] [Indexed: 11/01/2022] Open
Abstract
BACKGROUND Surgical approaches for total knee arthroplasty (TKA) include the medial parapatellar (MPA), subvastus (SV), midvastus (MV), and lateral parapatellar approach (LPA); it remains unclear which approach is superior. METHODS Patients having undergone TKA at our institution were retrospectively organized into matched groups according to surgical approach (MPA, MV, SV, or LPA). Outcomes between the groups were compared using the Short-Form 12 (SF-12), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Knee Society Score (KSS), and range of motion (ROM) up to 2 years postoperative. RESULTS Sixty-eight MV patients, 8 SV patients, and 4 LPA patients were matched with groups of MPA patients. There was no difference in outcomes between the MPA and MV groups up to 2 years. The SV group had significantly higher SF-12 Physical Composite Score (PCS; p = 0.036) and WOMAC stiffness score (p = 0.014) at 2 years, but significantly lower flexion at 1 year (p = 0.022) than the MPA group. The LPA group had significantly lower SF-12 PCS (p = 0.011) and WOMAC function scores (p = 0.022) at 1 year than the MPA group. CONCLUSION There was no significant difference between the MPA and MV approach. The SV approach had some improved long-term outcomes over the MPA aproach (SF-12 and WOMAC), but had significantly lower flexion at 1 year. The LPA group showed inferior outcomes than the MPA group but had more severe valgus preoperative deformity (p = 0.024). Further studies are required to investigate the potential benefit of quadriceps-sparing approaches.
Collapse
|
25
|
Comparison of long-term kinematics and wear of total knee arthroplasty implant designs. J Mech Behav Biomed Mater 2021; 124:104845. [PMID: 34555623 DOI: 10.1016/j.jmbbm.2021.104845] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 08/23/2021] [Accepted: 09/17/2021] [Indexed: 11/16/2022]
Abstract
We sought to evaluate wear and kinematics in well-established implants of posterior stabilized (PS) and cruciate retaining (CR) designs. Ninety-one knees implanted for at least five years were examined. The implants were Genesis II PS (Smith & Nephew, Memphis, TN), Sigma PS (DePuy Synthes, Warsaw, IN), or Sigma CR. Radiostereometric analysis (RSA) images were acquired at multiple flexion angles and the 3D positions of the implant components were determined using model-based RSA software. The location of the center of the contact area between the femoral and polyethylene components was used to obtain contact kinematics, and the magnitude of the virtual intersection between the components indicated linear wear. All three groups had paradoxical anterior motion on both condyles, experienced similar net external rotation, and exhibited instances of internal rotation during flexion. The maximum observed wear rate was significantly greater for the Sigma PS than the Genesis II PS on the medial condyle (mean difference = 0.032 mm/year, p = 0.044), but not the lateral condyle, while there was no difference between the Sigma PS and Sigma CR for either condyle. Knees with lateral condylar separation had greater maximum wear rates on the medial condyle (mean difference = 0.033 mm/year, p = 0.001), while those with medial condylar separation had greater maximum wear rates on the lateral condyle (mean difference = 0.044 mm/year, p = 0.014). At long term follow-up in patients with well-functioning implants, there were differences in kinematics and wear resistance between implants. These results suggest that implant design affects long-term kinematics and wear in well-functioning implants and that condylar separation should be avoided to minimize wear.
Collapse
|
26
|
Deciphering the low abundance microbiota of presumed aseptic hip and knee implants. PLoS One 2021; 16:e0257471. [PMID: 34520499 PMCID: PMC8439452 DOI: 10.1371/journal.pone.0257471] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2021] [Accepted: 09/01/2021] [Indexed: 11/18/2022] Open
Abstract
16S rRNA gene sequencing of DNA extracted from clinically uninfected hip and knee implant samples has revealed polymicrobial populations. However, previous studies assessed 16S rRNA gene sequencing as a technique for the diagnosis of periprosthetic joint infections, leaving the microbiota of presumed aseptic hip and knee implants largely unstudied. These communities of microorganisms might play important roles in aspects of host health, such as aseptic loosening. Therefore, this study sought to characterize the bacterial composition of presumed aseptic joint implant microbiota using next generation 16S rRNA gene sequencing, and it evaluated this method for future investigations. 248 samples were collected from implants of 41 patients undergoing total hip or knee arthroplasty revision for presumed aseptic failure. DNA was extracted using two methodologies-one optimized for high throughput and the other for human samples-and amplicons of the V4 region of the 16S rRNA gene were sequenced. Sequencing data were analyzed and compared with ancillary specific PCR and microbiological culture. Computational tools (SourceTracker and decontam) were used to detect and compensate for environmental and processing contaminants. Microbial diversity of patient samples was higher than that of open-air controls and differentially abundant taxa were detected between these conditions, possibly reflecting a true microbiota that is present in clinically uninfected joint implants. However, positive control-associated artifacts and DNA extraction methodology significantly affected sequencing results. As well, sequencing failed to identify Cutibacterium acnes in most culture- and PCR-positive samples. These challenges limited characterization of bacteria in presumed aseptic implants, but genera were identified for further investigation. In all, we provide further support for the hypothesis that there is likely a microbiota present in clinically uninfected joint implants, and we show that methods other than 16S rRNA gene sequencing may be ideal for its characterization. This work has illuminated the importance of further study of microbiota of clinically uninfected joint implants with novel molecular and computational tools to further eliminate contaminants and artifacts that arise in low bacterial abundance samples.
Collapse
MESH Headings
- Adult
- Aged
- Arthroplasty, Replacement, Hip
- Arthroplasty, Replacement, Knee
- Artifacts
- Bacteria/genetics
- Bacteria/isolation & purification
- Female
- Hip Joint/microbiology
- Humans
- Knee Joint/microbiology
- Male
- Microbiota
- Middle Aged
- Polymerase Chain Reaction
- Prosthesis-Related Infections/microbiology
- Prosthesis-Related Infections/pathology
- RNA, Ribosomal, 16S/chemistry
- RNA, Ribosomal, 16S/genetics
- RNA, Ribosomal, 16S/metabolism
- Sequence Analysis, DNA
Collapse
|
27
|
Prevalence and Outcomes of Unexpected Positive Intraoperative Cultures in Presumed Aseptic Revision Hip Arthroplasty. J Bone Joint Surg Am 2021; 103:1392-1401. [PMID: 33974575 DOI: 10.2106/jbjs.20.01559] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The prevalence and outcomes of unexpected positive cultures (UPCs) of specimens taken during presumed aseptic revision total hip arthroplasty (THA) are unclear. The purpose of this study was to determine the prevalence of UPC and infection-free implant survival in this patient population. Secondary aims included identifying factors associated with subsequent infection-related failure in patients with UPC. METHODS We reviewed all THA revisions (n = 2,288) performed at our institution from 2006 to 2019. Presumed aseptic revision THAs with intraoperative culture(s) were eligible (n = 1,196), and those with UPC were included in a Kaplan-Meier analysis to determine the infection-free implant survival and in Cox regression analysis to identify factors associated with infection-related failure. RESULTS UPC(s) were documented for 9.2% (110) of 1,196 aseptic THA revisions. The 2- and 5-year infection-free implant survival in the entire UPC cohort was 93.1% (95% confidence interval [CI] = 90.5% to 95.7%) and 86.8% (95% CI = 82.9% to 90.7%), respectively. The 2- and 5-year infection-free survival with failure due to infection with the same microorganism as identified in the UPC as the end point was 95.8% (95% CI = 93.7% to 97.9%) and 94.3% (95% CI = 91.7% to 96.9%), respectively. Subsequent infection-related failures caused by the same microorganism as identified in the UPC were more likely to occur after revisions with ≥2 UPCs than after those with 1 UPC (p = 0.024). Revision due to adverse metal reaction was a risk factor for subsequent infection-related failure (hazard ratio [HR] = 14.49, 95% CI = 2.69 to 78.04). Patients with a single UPC who were not treated with antibiotics had no subsequent periprosthetic joint infections (PJIs) caused by the same microorganism as identified in the UPC. CONCLUSIONS The prevalence of UPC was 9.2%, and the infection-free implant survival in patients with UPC is encouraging. Implant survival free of PJI caused by the same microorganism as identified in the UPC was excellent. Aseptic revision for adverse metal reaction was a risk factor for subsequent PJI in patients with UPC. No patient with a single UPC who was not treated with antibiotics developed PJI caused by the UPC-identified microorganism, suggesting that in the absence of other signs of infection a single UPC does not warrant antibiotic treatment. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
28
|
Effect of gap balancing and measured resection techniques on implant migration and contact kinematics of a cementless total knee arthroplasty. Knee 2021; 31:86-96. [PMID: 34119998 DOI: 10.1016/j.knee.2021.05.011] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Revised: 05/05/2021] [Accepted: 05/21/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND The purpose of this study was to compare implant migration and tibiofemoral contact kinematics of a cementless primary total knee arthroplasty (TKA) implanted using either a gap balancing (GB) or measured resection (MR) surgical technique. METHODS Thirty-nine patients underwent TKA via a GB (n = 19) or a MR (n = 20) surgical technique. Patients received an identical fixed-bearing, cruciate-retaining cementless implant. Patients underwent a baseline radiostereometric analysis (RSA) exam at two weeks post-operation, with follow-up visits at six weeks, three months, six months, and one year post-operation. Migration including maximum total point motion (MTPM) of the femoral and tibial components was calculated over time. At the one year visit patients also underwent a kinematic exam via RSA. RESULTS Mean MTPM of the tibial component at one year post-operation was not different (mean difference = 0.09 mm, p = 0.980) between the GB group (0.85 ± 0.37 mm) and the MR group (0.94 ± 0.41 mm). Femoral component MTPM at one year post-operation was also not different (mean difference = 0.27 mm, p = 0.463) between the GB group (0.62 ± 0.34 mm) and the MR group (0.89 ± 0.44 mm). Both groups displayed similar kinematic patterns. CONCLUSIONS There was no difference in implant migration and kinematics of a single-radius, cruciate retaining cementless TKA performed using a GB or MR surgical technique. The magnitude of migration suggests there is low risk of early loosening. The results provide support for using the cementless implant with either a GB or MR technique.
Collapse
|
29
|
Monitoring daily shoulder activity before and after reverse total shoulder arthroplasty using inertial measurement units. J Shoulder Elbow Surg 2021; 30:1078-1087. [PMID: 32771607 PMCID: PMC7409802 DOI: 10.1016/j.jse.2020.07.034] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 07/13/2020] [Accepted: 07/19/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND The purpose of this study was to use at-home, portable, continuous monitoring technologies to record arm motion and activity preoperatively and postoperatively after reverse total shoulder arthroplasty (RTSA). METHODS Thirty-three patients indicated for RTSA were monitored preoperatively and 3 and 12 months postoperatively. Inertial measurement units were placed on the sternum and upper arm of the operative limb, recording humeral motion relative to the torso for the duration of a waking day. Elevation events per hour (EE/h) > 90°, time spent at >90°, and activity intensity were calculated and compared between time points. Patient-reported outcome measures were also collected at all time points. RESULTS At 3 (P = .040) and 12 (P = .010) months after RTSA, patients demonstrated a significantly greater number of EE/h > 90° compared with preoperatively. There were no significant differences (P ≥ .242) in the amount of time spent at different elevation angles at any time point or in arm activity intensity. Overall, 95% of the day was spent at elevation angles < 60°, and 90% of the day was spent in a low- or moderate-intensity state. Pearson correlations demonstrated relationships between forward elevation and the number of EE/h (r = 0.395, P = .001) and the number of EE/h > 90° (r = 0.493, P < .001). CONCLUSION After RTSA, patients significantly increase the frequency of arm elevation to higher angles. However, we found no differences in the amount of time spent at different elevation angles. Overall, after RTSA, >95% of the day was spent at elevation angles < 60° and <1% of the day was spent at >90° of elevation.
Collapse
|
30
|
In vivo reverse total shoulder arthroplasty contact mechanics. J Shoulder Elbow Surg 2021; 30:421-429. [PMID: 32580021 DOI: 10.1016/j.jse.2020.05.036] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 05/19/2020] [Accepted: 05/24/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND Several in vitro studies have investigated the biomechanics of reverse total shoulder arthroplasty (RTSA); however, few in vivo studies exist. The purpose of this study was to examine in vivo RTSA contact mechanics in clinically relevant arm positions. Our hypothesis was that contact would preferentially occur in the inferior region of the polyethylene liner. METHODS Forty patients receiving a primary RTSA were recruited for a prospective cohort study. All patients received the same implant design with a nonretentive liner. Stereo radiographs were taken at maximal active range of motion. Model-based radiostereometric analysis was used to identify implant position. Contact area between the polyethylene and glenosphere was measured as the geometric intersection of the 2 components and compared with respect to polyethylene liner size, arm position, and relative position within the liner. RESULTS There were no differences in the proportion of contact area in any arm position between polyethylene liner sizes, ranging from 30% ± 17% to 38% ± 23% for 36-mm liners and 32% ± 21% to 41% ± 25% for 42-mm liners. Contact was equally distributed between the superior and inferior halves of the liner at each arm position (P = .06-.79); however, greater contact area was observed in the outer radius of the liner when the arm was flexed (P = .002). CONCLUSION This study highlights that contact mechanics are similar between 36- and 42-mm liners. Contact area is generally equally distributed throughout the liner across the range of motion and not preferentially in the inferior region as hypothesized.
Collapse
|
31
|
Machine Learning Predicts the Fall Risk of Total Hip Arthroplasty Patients Based on Wearable Sensor Instrumented Performance Tests. J Arthroplasty 2021; 36:573-578. [PMID: 32928593 DOI: 10.1016/j.arth.2020.08.034] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2020] [Revised: 08/10/2020] [Accepted: 08/17/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND The prevalence of falls affects the wellbeing of aging adults and places an economic burden on the healthcare system. Integration of wearable sensors into existing fall risk assessment tools enables objective data collection that describes the functional ability of patients. In this study, supervised machine learning was applied to sensor-derived metrics to predict the fall risk of patients following total hip arthroplasty. METHODS At preoperative, 2-week, and 6-week postoperative appointments, patients (n = 72) were instrumented with sensors while they performed the timed-up-and-go walking test. Preoperative and 2-week postoperative data were used to form the feature sets and 6-week total times were used as labels. Support vector machine and linear discriminant analysis classifier models were developed and tested on various combinations of feature sets and feature reduction schemes. Using a 10-fold leave-some-subjects-out testing scheme, the accuracy, sensitivity, specificity, and area under the receiver-operator curve (AUC) were evaluated for all models. RESULTS A high performance model (accuracy = 0.87, sensitivity = 0.97, specificity = 0.46, AUC = 0.82) was obtained with a support vector machine classifier using sensor-derived metrics from only the preoperative appointment. An overall improved performance (accuracy = 0.90, sensitivity = 0.93, specificity = 0.59, AUC = 0.88) was achieved with a linear discriminant analysis classifier when 2-week postoperative data were added to the preoperative data. CONCLUSION The high accuracy of the fall risk prediction models is valuable for patients, clinicians, and the healthcare system. High-risk patients can implement preventative measures and low-risk patients can be directed to enhanced recovery care programs.
Collapse
|
32
|
Evaluation of the Effect of Gait Aids, Such as Canes, Crutches, and Walkers, on the Accuracy of Step Counters in Healthy Individuals. Orthop Res Rev 2021; 13:1-8. [PMID: 33447097 PMCID: PMC7802358 DOI: 10.2147/orr.s292255] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Accepted: 12/22/2020] [Indexed: 01/01/2023] Open
Abstract
Background Wearable step-counter devices have become inexpensive tools that enable patients, researchers, and clinicians to objectively monitor physical activity. It is unknown how the use of gait aids, such as canes, crutches, and walkers, affects the accuracy of these devices. Such gait aids are commonly used by patients with chronic physical impairment and after joint-replacement surgery. The aim of this study was to determine the effect of gait aids on the accuracy of wearable step counters. Methods Nine healthy participants wore a Fitbit step counter on their wrist and hip and performed eight walking tests with canes, crutches, and walkers. Bland-Altman analyses were performed for all eight walking tests in order to compare agreement between measurement techniques. Results Mean overall agreement for subjects walking without gait aids in the hip group was excellent, showing a bias of -2.9, with limits of agreement (LOAs) between -8.72 and 2.95. For use of canes or crutches, the Bland-Altman plots had a range of bias values between the hip and wrist counters from -7.22 to 33.56, with LOAs from -98.55 to 124.2. The wrist counter during the four-wheeled walking test showed very little agreement with the actual step count, with a bias value of 91.33 and LOAs of 64.1-118.6, illustrating exceptionally unreliable step counts. Conclusion This study suggests that these widely commercially available step counters have poor reliability with gait aids, especially walkers, which should be taken into account in research and clinical settings.
Collapse
|
33
|
Machine learning and wearable sensors at preoperative assessments: Functional recovery prediction to set realistic expectations for knee replacements. Med Eng Phys 2020; 89:14-21. [PMID: 33608121 DOI: 10.1016/j.medengphy.2020.12.007] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 11/30/2020] [Accepted: 12/22/2020] [Indexed: 11/19/2022]
Abstract
Unmet expectations contribute to a high patient dissatisfaction rate following total knee replacement but clinicians currently do not have the tools to confidently adjust expectations. In this study, supervised machine learning was applied to multi-variate wearable sensor data from preoperative timed-up-and-go tests. Participants (n=82) were instrumented three months after surgery and patients showing relevant improvement were designated as "responders" while the remainder were labelled "maintainers". Support vector machine, naïve Bayes, and random forest binary classifiers were developed to distinguish patients using sensor-derived features. Accuracy, sensitivity, specificity, and area under the receiver-operator curve (AUC) were compared between models using ten-fold out-of-sample testing. A high performance using only sensor-derived functional metrics was obtained with a random forest model (accuracy = 0.76 ± 0.11, sensitivity = 0.87 ± 0.08, specificity = 0.57 ± 0.26, AUC = 0.80 ± 0.14) but highly sensitive models were observed using naïve Bayes and SVM models after including patient age, sex, and BMI into the feature set (accuracy = 0.72, 0.73 ± 0.09, 0.12; sensitivity = 0.94, 0.95 ± 0.11, 0.11; specificity = 0.35, 0.37 ± 0.20, 0.18; AUC = 0.80, 0.74 ± 0.07, 0.11; respectfully). Including select patient-reported subjective measures increased the top random forest performance slightly (accuracy = 0.80 ± 0.10, sensitivity = 0.91 ± 0.14, specificity = 0.62 ± 0.23, AUC = 0.86 ± 0.09). The current work has demonstrated that prediction models developed from preoperative sensor-derived functional metrics can reliably predict expected functional recovery following surgery and this can be used by clinicians to help set realistic patient expectations.
Collapse
|
34
|
The effect of femoral stem collar on implant migration and clinical outcomes following direct anterior approach total hip arthroplasty. Bone Joint J 2020; 102-B:1654-1661. [PMID: 33249909 DOI: 10.1302/0301-620x.102b12.bjj-2019-1428.r1] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
AIMS The direct anterior (DA) approach has been associated with rapid patient recovery after total hip arthroplasty (THA) but may be associated with more frequent femoral complications including implant loosening. The objective of this study was to determine whether the addition of a collar to the femoral stem affects implant migration, patient activity, and patient function following primary THA using the DA approach. METHODS Patients were randomized to either a collared (n = 23) or collarless (n = 26) cementless femoral stem implanted using the DA approach. Canal fill ratio (CFR) was measured on the first postoperative radiographs. Patients underwent a supine radiostereometric analysis (RSA) exam postoperatively on the day of surgery and at two, four, six, 12, 26, and 52 weeks postoperatively. Patient-reported outcome measures (Western Ontario and McMaster Universities Osteoarthritis (WOMAC) Index, the 12-item Short Form Health Survey Mental and Physical Score, and University of California, Los Angeles (UCLA) Activity Score) were measured preoperatively and at each post-surgery clinic visit. Activity and function were also measured as the weekly average step count recorded by an activity tracker, and an instrumented timed up-and-go (TUG) test in clinic, respectively. RESULTS Comparing the RSA between the day of surgery baseline exam to two weeks postoperatively, subsidence was significantly lower (mean difference 2.23 mm (SD 0.71), p = 0.023) with collared stems, though these patients had a greater CFR (p = 0.048). There was no difference (p = 0.426) in subsidence between stems from a two-week baseline through to one year postoperatively. There were no clinically relevant differences in PROMs; and there was no difference in the change in activity (p = 0.078) or the change in functional capacity (p = 0.664) between the collared stem group and the collarless stem group at any timepoint. CONCLUSION Presence of a collar on the femoral stem resulted in reduced subsidence during the first two postoperative weeks following primary THA using the DA approach. However, the clinical implications are unclear, and larger studies examining patient activity and outcomes are required. Cite this article: Bone Joint J 2020;102-B(12):1654-1661.
Collapse
|
35
|
Minimum ten-year follow-up of a randomized trial comparing acetabular component fixation of two porous in-growth surfaces using radiosteriometric analysis. Bone Jt Open 2020; 1:653-662. [PMID: 33215098 PMCID: PMC7659663 DOI: 10.1302/2633-1462.110.bjo-2020-0118.r1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Aims To compare the in vivo long-term fixation achieved by two acetabular components with different porous ingrowth surfaces using radiostereometric analysis (RSA). Methods This was a minimum ten-year follow-up of a prospective randomized trial of 62 hips with two different porous ingrowth acetabular components. RSA exams had previously been acquired through two years of follow-up. Patients returned for RSA examination at a minimum of ten years. In addition, radiological appearance of these acetabular components was analyzed, and patient-reported outcome measures (PROMs) obtained. Results In all, 15 hips were available at ten years. There was no statistically significant difference in PROMS between the two groups; PROMs were improved at ten years compared to preoperative scores. Conventional radiological assessment revealed well-fixed components. There was minimal movement for both porous surfaces in translation (X, Y, Z, 3D translation in mm (median and interquartile range (IQR)), StikTite (Smith and Nephew, Memphis, Tennessee, USA): 0.03 (1.08), 0.12 (0.7), 0.003 (2.3), 0.37 (0.30), and Roughcoat (Smith and Nephew): -0.6 (0.59),–0.1 (0.49), 0.1 (1.12), 0.48 (0.38)), and rotation (X, Y, Z rotation in degrees (median and IQR), (Stiktite: -0.4 (3), 0.28 (2), -0.2 (1), and Roughcoat: - 0.4 (1),–0.1 (1), 0.2 (2)). There was no statistically significant difference between the two cohorts (p-value for X, Y, Z, 3D translation - 0.54, 0.46, 0.87, 0.55 and for X, Y, Z rotation - 0.41, 0.23, 0.23 respectively) at ten years. There was significant correlation between two years and ten years 3D translation for all components (r = 0.81(p =< 0.001)). Conclusion Both porous ingrowth surfaces demonstrated excellent fixation on plain radiographs and with RSA at ten years. Short-term RSA data are good predictors for long-term migration data.
Collapse
|
36
|
Contact kinematics of patient-specific instrumentation versus conventional instrumentation for total knee arthroplasty. Knee 2020; 27:1501-1509. [PMID: 33010767 DOI: 10.1016/j.knee.2020.07.092] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 06/24/2020] [Accepted: 07/30/2020] [Indexed: 02/02/2023]
Abstract
BACKGROUND The goal was to evaluate the joint contact kinematics of total knee arthroplasties implanted using patient-specific instrumentation (PSI) compared to conventional instrumentation (CI). We hypothesized that use of PSI would not significantly alter contact kinematics. METHODS The study was a prospective randomized controlled trial, with equal allocation of fifty patients to PSI and CI groups. At two years post-operation, patients underwent weight-bearing stereo X-ray examinations at 0°, 20°, 40°, 60°, 80°, and 100° of flexion. The shortest tibiofemoral distance on each condyle determined the contact location. Magnitude of the shortest distance was measured and condylar separation was analyzed using thresholds of 0.5 and 0.75 mm. Kinematic measurements derived from the shortest distance included anteroposterior (AP) translation, excursion, axial rotation, and paradoxical anterior motion. Pivot position and cam/post contact were also investigated. RESULTS There were no differences (p > 0.05) in medial and lateral AP contact locations, excursions, and magnitude of anterior motion, or in axial rotation, pivot patterns, frequency of cam/post engagement, frequency of medial anterior motion, and condylar separation at a 0.75 mm threshold. Significant differences were found in frequency of lateral anterior motion (p = 0.048) and condylar separation at a 0.5 mm threshold (p = 0.010). Both groups displayed typical kinematics for a fixed-bearing posterior-stabilized implant. CONCLUSIONS We found no major differences in knee kinematics between PSI and CI groups, which suggest that PSI does not provide a significant kinematic advantage over conventional instruments.
Collapse
|
37
|
In vivo volumetric and linear wear measurement of reverse shoulder arthroplasty at minimum 5-year follow-up. J Shoulder Elbow Surg 2020; 29:1695-1702. [PMID: 32192882 DOI: 10.1016/j.jse.2019.11.031] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/16/2019] [Revised: 11/11/2019] [Accepted: 11/23/2019] [Indexed: 02/01/2023]
Abstract
BACKGROUND Reverse shoulder arthroplasty is quickly becoming the most frequently performed glenohumeral joint replacement. The purpose of this study was to evaluate the volumetric and linear wear rates of ultrahigh-molecular-weight polyethylene humeral liners in vivo at a minimum 5-year follow-up. METHODS Radiostereometric analysis was used to image 15 patients at terminal range of motion in forward flexion, abduction, external rotation, and internal rotation and with the arm at the side. The relative position and orientation of the glenosphere and polyethylene were identified for each arm position. The apparent intersection of the glenosphere into the polyethylene was recorded as wear. Mean volumetric and linear wear rates were recorded, and Pearson correlation coefficients were applied to the 36-mm liners to assess the relationship between the wear rate and term of service. RESULTS The mean reverse shoulder arthroplasty term of service at the time of imaging was 8 ± 1 years (range, 6-11 years). The mean volumetric and linear wear rates for the 36-mm liners (n = 13) were 42 ± 22 mm3/yr (r = 0.688, P = .009) and 0.11 ± 0.03 mm/yr (r = 0.767, P = .002), respectively. The mean volumetric and linear wear rates for the 42-mm liners (n = 2) were 114 ± 44 mm3/yr and 0.17 ± 0.01 mm/yr, respectively. No single arm position was able to capture all recorded wear individually. CONCLUSION This study showed volumetric and linear wear rates of approximately 40 mm3/yr and 0.1 mm/yr, respectively, for the 36-mm polyethylene liners. The 42-mm liners showed higher wear rates, although a greater number of subjects is required for conclusive results. In vivo wear of reverse total shoulder arthroplasty is multidirectional and perceptible.
Collapse
|
38
|
Image-based design and 3D-metal printing of a rat hip implant for use in a clinically representative model of joint replacement. J Orthop Res 2020; 38:1627-1636. [PMID: 32369210 DOI: 10.1002/jor.24706] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/31/2019] [Revised: 04/06/2020] [Accepted: 04/23/2020] [Indexed: 02/04/2023]
Abstract
The aim of this study was to obtain micro-computed tomography derived measurements of the rat proximal femur, to create parameterized rat hip implants that could be surgically installed in a clinically representative small animal model of joint replacement. The proximal femoral anatomy of N = 25 rats (male, Sprague-Dawley, 390-605 g) was quantified. Key measurements were used to parameterize computer-aided design models of monoblock rat femoral implants. Linear regression analysis was used to determine if rat hip dimensions could be predicted from animal weight. A correlation analysis was used to determine how implants could be scaled to create a range of sizes. Additive manufacturing (3D printing) was used to create implants in medical-grade metal alloys. Linear regressions comparing rat weight to femoral head diameter and neck-head axis length revealed a significant nonzero slope (P < .05). Pearson's correlation analysis revealed five significant correlations between key measurements in the rat femur (P < .05). Implants were installed into both cadaveric and live animals; iterative design modifications were made to prototypes based on these surgical findings. Animals were able to tolerate the installation of implants and were observed ambulating on their affected limbs postoperatively. Clinical significance: We have developed a preclinical rat hip hemiarthroplasty model using image-based and iterative design techniques to create 3D-metal printed implants in medical-grade metal alloys. Our findings support further development of this model for use as a low-cost translational test platform for preclinical orthopaedic research into areas such as osseointegration, metal-on-cartilage wear, and periprosthetic joint infection.
Collapse
|
39
|
The Effects of Resection Technique on Implant Migration in Single Radius Posterior-Stabilized Total Knee Replacement. J Knee Surg 2020; 33:78-83. [PMID: 30562833 DOI: 10.1055/s-0038-1676462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The purpose of the present study was to measure the effects of gap balancing and resection techniques on migration of a single total knee replacement implant design. A total of 23 patients (24 knees) were recruited on referral to either a surgeon performing gap balancing or a surgeon performing measured resection and followed prospectively. All patients received a fixed bearing, posterior stabilized total knee replacement implant of a single radius femoral component design with cement fixation, and all aspects of care outside of resection technique were identical. Patients underwent radiostereometric analysis (RSA) at 2 weeks (baseline), 6 weeks, 3 months, 6 months, 1 year, and 2 years. Migration of the tibial and femoral components was compared between groups. Tibial component migration was greater at 2 years in the gap balancing group (mean difference = 0.336 mm, p = 0.036), but there was no difference at 1 year. One measured resection and three gap balancing tibial components demonstrated continuous migration > 0.2 mm between years 1 and 2. There was no difference in femoral component migration. Small differences in tibial component migration were found between the gap balancing and measured resection techniques. However, comparing the migration to established predictive thresholds for long-term loosening risk, implants performed with both techniques were found to have equally low revision risk.
Collapse
|
40
|
Correlation between hip osteoarthritis and the level of physical activity as measured by wearable technology and patient-reported questionnaires. J Orthop 2019; 20:236-239. [PMID: 32071522 DOI: 10.1016/j.jor.2019.11.049] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2019] [Accepted: 11/24/2019] [Indexed: 10/25/2022] Open
Abstract
This study evaluates physical activity in patients with advanced hip OA using Fitbit and whether a correlation exists between the number of steps taken per day (SPD) and the reported outcome. Methods 122 patients were prospective enrolled. Patient-reported outcomes were collected. Patients were asked to wear a Fitbit for 24 h a day on seven consecutive days. Result The mean number of SPD was 5721 ± 3920. The UCLA, HHS and SF-12 PCS demonstrated a statistically significant positive correlation with the SPD. Conclusion Wearable technology is reliable in objectively measuring the level of physical activity in hip OA and correlates with reported outcomes.
Collapse
|
41
|
Femoral head material loss at the head-neck junction in total hip arthroplasty: the effect of head size, stem material and stem offset. Hip Int 2019; 29:647-651. [PMID: 30499342 DOI: 10.1177/1120700018814473] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Material loss at the head-neck junction in total hip arthroplasty may cause adverse clinical symptoms and implant failure. The purpose of this study was to quantitatively examine the effects of head size, stem material and stem offset on material loss of the head-neck taper interface of a single trunnion design in retrieval implants of metal on polyethylene bearing surfaces. METHODS A retrieval study was performed to identify all 28-mm and 32-mm femoral heads from a single implant/taper design implanted for >2 years. This included n = 56 of the 28-mm heads and n = 23 of the 32-mm heads. The 28-mm femoral heads were matched to 32-mm femoral heads based on time in vivo and head length. A coordinate measuring machine was used to determine maximum linear corrosion depth (MLD). Differences in MLD for head diameter, stem material, and stem offset were determined. RESULTS There were no differences between groups for age, gender, BMI, or implantation time. There was no difference in MLD between 28 mm and 32 mm matched paired head diameters (p = 0.59). There was also no difference in MLD between titanium or cobalt-chromium stems (p = 0.79), and regular or high-offset stems (p = 0.95). CONCLUSION There is no statistical difference in femoral head MLD at the head-neck junction in THA between 28-mm and 32-mm matched paired femoral heads, similar or mixed alloy coupled femoral head stem constructs, and regular or high offset stems.
Collapse
|
42
|
Machine Learning Groups Patients by Early Functional Improvement Likelihood Based on Wearable Sensor Instrumented Preoperative Timed-Up-and-Go Tests. J Arthroplasty 2019; 34:2267-2271. [PMID: 31255408 DOI: 10.1016/j.arth.2019.05.061] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Revised: 05/13/2019] [Accepted: 05/29/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Wearable sensors permit efficient data collection and unobtrusive systems can be used for instrumenting knee patients for objective assessment. Machine learning can be leveraged to parse the abundant information these systems provide and segment patients into relevant groups without specifying group membership criteria. The objective of this study is to examine functional parameters influencing favorable recovery outcomes by separating patients into functional groups and tracking them through clinical follow-ups. METHODS Patients undergoing primary unilateral total knee arthroplasty (n = 68) completed instrumented timed-up-and-go tests preoperatively and at their 2-, 6-, and 12-week follow-up appointments. A custom wearable system extracted 55 metrics for analysis and a K-means algorithm separated patients into functionally distinguished groups based on the derived features. These groups were analyzed to determine which metrics differentiated most and how each cluster improved during early recovery. RESULTS Patients separated into 2 clusters (n = 46 and n = 22) with significantly different test completion times (12.6 s vs 21.6 s, P < .001). Tracking the recovery of both groups to their 12-week follow-ups revealed 64% of one group improved their function while 63% of the other maintained preoperative function. The higher improvement group shortened their test times by 4.94 s, (P = .005) showing faster recovery while the other group did not improve above a minimally important clinical difference (0.87 s, P = .07). Features with the largest effect size between groups were distinguished as important functional parameters. CONCLUSION This work supports using wearable sensors to instrument functional tests during clinical visits and using machine learning to parse complex patterns to reveal clinically relevant parameters.
Collapse
|
43
|
Abstract
INTRODUCTION Modular designs enhance accuracy of limb length and offset during total hip arthroplasty. However, such interfaces can be the site of corrosion and implant failure. The purpose of this study was to review 5 cases of catastrophic femoral head trunnion dissociation to better understand clinical and implant related risk factors for this complication. METHODS We describe 5 cases of femoral head dissociation following significant trunnion wear. Patient and implant related factors are reviewed. Surface wear patterns were assessed using electron microscopy and wear patterns were described qualitatively. RESULTS Commonalties among 5 presented cases include male, age over 65 and increased BMI. All femoral heads were cobalt chromium with a head size of at least 36 mm or greater. 4 out of 5 had high offset. All stems were the same design. Surface wear analysis showed material removed initially on the inferomedial aspect of the trunnion where the femoral head contacted the stem. CONCLUSIONS Femoral head dissociation secondary to failure of the trunnion is a rare complication. We show associations with older age, increased BMI and male patients with increased femoral head size and offset. Material is removed initially inferomedially and progresses to fracturing the superior aspect of the trunnion.
Collapse
|
44
|
Abstract
INTRODUCTION Corrosion at head neck taper junctions in total hip arthroplasty has increasingly been reported in the literature. Debate persists as to the exact causes and clinical significance of corrosion. Increased offset and head length has been correlated with an increased risk of tribocorrosion due to an adverse mechanical environment. The purpose of this study is to assess the effect of head length on corrosion of a metal-on-polyethylene articulation. METHODS Retrievals from a single institution of 28-mm cobalt chromium alloy heads with a 12/14 taper from a single manufacturer were studied. Corrosion of femoral head bores were studied utilising a material loss method. Testing was performed using co-ordinate measuring for maximum linear wear depth. RESULTS 56 heads were examined with lengths of either -3, 0, +4 or +8 mm and all had been in situ for a minimum of 2 years. There were no significant differences in mean maximum linear wear depth (MLWD) (p = 0.6545). There was no correlation found between MLWD and the time implants were in situ (Spearman coefficient -0.1157) and no significant difference seen between high or standard offset stems (p = 0.1336). CONCLUSION In contrast to studies using qualitative methodologies, there was no correlation between head length and material loss when confined to a 28-mm head. Broad application of this outcome should be cautioned against as this study examined 1 taper construct and a metal-on-polyethylene articulation.
Collapse
|
45
|
Validation of In Vivo Linear and Volumetric Wear Measurement for Reverse Total Shoulder Arthroplasty Using Model-Based Radiostereometric Analysis. J Orthop Res 2019; 37:1620-1627. [PMID: 30977541 DOI: 10.1002/jor.24294] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Presently, polyethylene wear measurement of reverse total shoulder arthroplasty (rTSA) is restricted to in vitro, in silico, and retrieval analysis, with no method for the quantification of in vivo wear of well-functioning implants. The purpose of this study was to validate the use of model-based radiostereometric analysis (MBRSA) as a measurement tool for in vivo rTSA wear using a phantom setup. Six additively manufactured polyethylene inserts were fabricated, one unworn control and five to represent known wear patterns, and individually fit within the rTSA components. Each insert was imaged using standard radiostereometric techniques and analyzed using MBRSA. From the position and orientation estimation provided by MBRSA, a micro-computed tomography model of the control insert was virtually placed within the metaphyseal tray. The apparent intersection of the glenosphere into the insert was recorded as wear. This method enables wear measurements with a linear precision of 0.21 mm and a bias of 0.36 ± 0.13 mm, and a volumetric precision of 49.3 mm3 , with a bias of 48.9 ± 24.3 mm3 . This technique allows for the in vivo measurement of polyethylene wear without the requirement of marker beads or baseline radiographs, expanding the potential for in vivo wear measurements to larger populations and retrospective analysis. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:1620-1627, 2019.
Collapse
|
46
|
Effect of Medial Soft Tissue Releases During Posterior-Stabilized Total Knee Arthroplasty on Contact Kinematics and Patient-Reported Outcomes. J Arthroplasty 2019; 34:1110-1115. [PMID: 30917888 DOI: 10.1016/j.arth.2019.02.026] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/13/2018] [Revised: 02/03/2019] [Accepted: 02/14/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Minimal to extensive medial soft tissue releases are part of the exposure and achieving adequate varus knee balance in total knee arthroplasty (TKA). However, the effect of these releases on knee kinematics and patient-reported outcomes is unclear. Our objective was to compare the postoperative in vivo tibiofemoral contact kinematics of a posterior-stabilized TKA between patients who received minimal medial soft tissue releases intraoperatively to those who received extensive releases. We also compared these groups using patient-reported outcomes. METHODS A prospective imaging study was performed in a single-center over a 14-month period. Patients with end-stage osteoarthritis and varus deformity undergoing primary TKA were included. Baseline data were collected 1 month before surgery. The radiostereometric analysis imaging took place at least 1 year postoperatively and composed of weight-bearing radiographic stereo examinations of knee flexion starting in full extension and in 20° increments of flexion to a maximum of 120°. Intraoperative medial soft tissue releases were recorded. Patient-reported outcomes used included Short-Form 12, Western Ontario and McMaster Osteoarthritis Index, and Knee Society Score. RESULTS Fifty-one patients were included in the statistical analysis. Demographic characteristics were similar between all. Patients were divided into 3 groups depending on the amount of releases they received. No statistically significant differences in tibiofemoral contact positions or excursions on the medial or lateral condyles were found throughout flexion from 0° to 120°. Postoperative patient-reported outcome scores were not different. CONCLUSION Correcting severe varus deformities with extensive medial soft tissue release largely did not alter knee kinematics or clinical outcome scores compared to those with minimal soft tissue release.
Collapse
|
47
|
Proposal and Validation of a Knee Measurement System for Patients With Osteoarthritis. IEEE Trans Biomed Eng 2019; 66:319-326. [DOI: 10.1109/tbme.2018.2837620] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
48
|
Repeatability of measuring knee flexion angles with wearable inertial sensors. Knee 2019; 26:97-105. [PMID: 30554906 DOI: 10.1016/j.knee.2018.11.002] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2018] [Revised: 10/29/2018] [Accepted: 11/03/2018] [Indexed: 02/02/2023]
Abstract
BACKGROUND As assessment with inertial-measurement-units (IMUs) increases in research and in clinics, it is important to be aware of the repeatability of these sensors. The objectives of this experiment were to evaluate the measurement repeatability of IMU joint angles using a repeatable robot controller and an anthropomorphic leg phantom and to determine effects of joint speed and sensor positioning on the angles collected by these sensors. Comparisons to an electro-goniometer and three-dimensional (3D) motion capture cameras were also completed. METHODS Two dual-IMU setups (posterior and lateral) were tested concurrently with an electro-goniometer and 3D motion capture cameras using a repeatable robot controller and a leg phantom. All modalities were attached to the phantom, which was flexed 10 times using a pre-programmed motion pathway during each test. Mean angles were compared across tests. Effects of joint speed, sensor re-positioning, and anatomical placement of the sensors on repeatability were assessed. RESULTS Re-positioning caused greater deviation to the maximum and minimum angles than differences in speed. Overall, the means ± standard deviations, and 95% confidence intervals of the maximum angles across all tests for the 3D camera markers, electro-goniometer, posterior IMUs, and lateral IMUs were 119.4 ± 0.3° (119.4, 119.5), 112.4 ± 0.5° (112.3, 112.5), 116.2 ± 2.4° (115.7, 116.7), and 118.3 ± 1.1° (118.1, 118.6). CONCLUSIONS Both posterior and lateral IMU setups demonstrated acceptable repeatability in measurement of range of motion that was advantageous to manual goniometer methods. Posterior and lateral IMU setups demonstrated overlapping standard deviations about their means.
Collapse
|
49
|
Surface integrity of polyethylene liners following trunnionosis of a dual modular neck total hip implant. Hip Int 2018; 28:629-635. [PMID: 29756511 DOI: 10.1177/1120700018754336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND There has been a trend in the evolution of total hip arthroplasty towards increased modularity; with this increase in modularity come some potentially harmful consequences. Modularity at the neck shaft junction has been linked to corrosion, adverse reaction to metal debris and pseudotumour formation. AIM The aim of this retrieval study is to assess whether the surface integrity of the polyethylene (PE) liner is affected by metal wear debris in a single implant design series of THA revised for trunnionosis. METHODS A retrieval analysis of thirty dual-taper modular neck hip prostheses was performed; the mean time from implantation to revision was 2.7 years (1.02-6.2). PE liners were analysed using a scanning electron microscope with an energy dispersive spectrometer to assess for metal particles embedded on the liner surface. Serum metal ion levels and inflammatory markers were also analysed. RESULTS There were small numbers of metal particles present on the PE liners. The mean number of metal particles per liner was four and the particles varied in size from 0.5 µm to 122 µm mean 16 µm. All patients had elevated metal ion levels: cobalt 6.02 µg/l, chromium 1.22 µg/l, titanium 3.11 µg/l. The cobalt:chromium ratio was 7.55:1. Inflammatory markers were also marginally raised (ESR 17; CRP 10). CONCLUSION These results suggest that retention of PE liners may be reasonable when performing isolated revision of the femoral component in cases of failure at the modular neck stem junction, especially when the inner diameter of the liner is already optimised for head size and stability.
Collapse
|
50
|
Corrigendum to 'Factors Affecting Wear of Constrained Polyethylene Tibial Inserts in Total Knee Arthroplasty' [Journal of Arthroplasty 31 (2016) 1340-1345]. J Arthroplasty 2018; 33:3593. [PMID: 30122433 DOI: 10.1016/j.arth.2018.07.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
|