1
|
Evaluation of hard palate and cleft morphology in neonates with Pierre Robin Sequence and Cleft Palate Only. Orthod Craniofac Res 2024. [PMID: 38783751 DOI: 10.1111/ocr.12818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/11/2024] [Indexed: 05/25/2024]
Abstract
OBJECTIVES This study aimed to establish a fully digital measurement protocol for standardizing the description of hard palate and cleft morphology in neonates with an isolated cleft palate (CPO) and Pierre Robin sequence (PRS). MATERIALS AND METHODS A total of 20 digitized plaster models of neonates with CPO and 20 digitized plaster models of neonates with PRS were retrospectively investigated. For the control group, the hard palate was segmented from 21 pre-existing 1.5 T MRI datasets of neonates and exported as an STL file. The digital models were marked with predefined reference points by three raters. Distance, angular, and area measurements were performed using Blender and MeshLab. RESULTS Neonates with CPO (20.20 ± 2.33 mm) and PRS (21.41 ± 1.81 mm) had a significantly shorter hard palate than the control group (23.44 ± 2.24 mm) (CPO vs. control: P < .001; PRS vs. control: P = .014). Notably, neonates with PRS (33.05 ± 1.95 mm) demonstrated a significantly wider intertuberosity distance than those with CPO (30.52 ± 2.28 mm) (P = .012). Furthermore, there were also significant differences measured between the cleft and control groups (25.22 ± 2.50 mm) (P < .001). CONCLUSIONS The data from this study demonstrate the feasibility of using MRI datasets to generate digital models of the hard palate. The presence of a cleft palate leads to pronounced adaptations of the total palatal surface area, dorsal width, and length of the hard palate. Mandibular retrognathia and altered tongue position in PRS, as opposed to CPO, might further impact palatal morphology and intertuberosity distance.
Collapse
|
2
|
Feasibility of 3 Tesla MRI for the assessment of mid-palatal suture maturation: a retrospective pilot study. Odontology 2024:10.1007/s10266-024-00950-0. [PMID: 38758257 DOI: 10.1007/s10266-024-00950-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Accepted: 05/04/2024] [Indexed: 05/18/2024]
Abstract
The maxilla occupies a key position in dentofacial orthopaedics, since its transversal development can be directly influenced by orthodontic therapy. The maturation stages of the mid-palatal suture, which are obtained from cone-beam computed tomography images (CBCT), present an addition to clinical decision-making in transversal discrepancies of the upper jaw. In an endeavour to reduce ionizing radiation in adolescents and young adults, who are particularly susceptible to long term stochastic irradiation effects, we investigated the feasibility of 3 Tesla (3T) MRI in detecting the maturation stages of the mid-palatal suture. A collective of 30 patients aged 24-93 years with routine neck MRI at 3T, underwent an additional three-dimensional isotropic T1 weighted study sequence of the midface. Image evaluation was performed on axial, multi-planar formatted reconstructions of the dataset aligned to the midline axis of the palate, and curved reconstructions aligned to the concavity of the palate. Inverted images helped to achieve an image impression similar to the well-known CBCT appearance. All datasets were reviewed by three readers and mid-palatal maturation was scored twice according to Angelieri et al. Intra- and inter-rater agreement were evaluated to measure the robustness of the images for clinical evaluation. 3T MRI deemed reliable for the assessment of mid-palatal suture maturation and hence for the appraisal of the hard palate and its adjacent sutures. The data of this pilot study display the feasibility of non-ionizing cross-sectional MRI for the determination of sutural maturation stages. These findings underline the potential of MRI for orthodontic treatment planning, further contributing to the avoidance of unnecessary radiation doses.
Collapse
|
3
|
Editorial for "Magnetic Resonance Imaging-Based Classification Systems for Informing Better Outcomes of Adenomyosis After Ultrasound-Guided High-Intensity Focused Ultrasound Ablating Surgery". J Magn Reson Imaging 2024; 59:1798-1799. [PMID: 37702415 DOI: 10.1002/jmri.28988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Accepted: 08/11/2023] [Indexed: 09/14/2023] Open
|
4
|
Highly accelerated, Dixon-based non-contrast MR angiography versus high-pitch CT angiography. LA RADIOLOGIA MEDICA 2024; 129:268-279. [PMID: 38017228 PMCID: PMC10879221 DOI: 10.1007/s11547-023-01752-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Accepted: 11/07/2023] [Indexed: 11/30/2023]
Abstract
OBJECTIVES To compare a novel, non-contrast, flow-independent, 3D isotropic magnetic resonance angiography (MRA) sequence that combines respiration compensation, electrocardiogram (ECG)-triggering, undersampling, and Dixon water-fat separation with an ECG-triggered aortic high-pitch computed tomography angiography (CTA) of the aorta. MATERIALS AND METHODS Twenty-five patients with recent CTA were scheduled for non-contrast MRA on a 3 T MRI. Aortic diameters and cross-sectional areas were measured on MRA and CTA using semiautomatic measurement tools at 11 aortic levels. Image quality was assessed independently by two radiologists on predefined aortic levels, including myocardium, proximal aortic branches, pulmonary veins and arteries, and the inferior (IVC) and superior vena cava (SVC). Image quality was assessed on a 5-point Likert scale. RESULTS All datasets showed diagnostic image quality. Visual grading was similar for MRA and CTA regarding overall image quality (0.71), systemic arterial image quality (p = 0.07-0.91) and pulmonary artery image quality (p = 0.05). Both readers favored MRA for SVC and IVC, while CTA was preferred for pulmonary veins (all p < 0.05). No significant difference was observed in aortic diameters or cross-sectional areas between native MRA and contrast-enhanced CTA (p = 0.08-0.94). CONCLUSION The proposed non-contrast MRA enables robust imaging of the aorta, its proximal branches and the pulmonary arteries and great veins with image quality and aortic diameters and cross-sectional areas comparable to that of CTA. Moreover, this technique represents a suitable free-breathing alternative, without the use of contrast agents or ionizing radiation. Therefore, it is especially suitable for patients requiring repetitive imaging.
Collapse
|
5
|
Impact of different cephalometric skeletal configurations on anatomic midface parameters in adults. Clin Oral Investig 2023; 28:55. [PMID: 38157063 PMCID: PMC10756868 DOI: 10.1007/s00784-023-05472-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Accepted: 12/20/2023] [Indexed: 01/03/2024]
Abstract
OBJECTIVES Skull morphology and growth patterns are essential for orthodontic treatment, impacting clinical decision making. We aimed to determine the association of different cephalometric skeletal configurations on midface parameters as measured in 3D CT datasets. MATERIALS AND METHODS After sample size calculation, a total of 240 fully dentulous patients between 20 and 79 years of age (mean age: 42 ± 15), who had received a CT of the skull within the scope of trauma diagnosis or intracranial bleeding, were retrospectively selected. On the basis of cephalometric analysis, using MPR reconstructions, patients were subdivided into three different vertical skull configurations (brachyfacial, mesofacial, dolichofacial) and the respective skeletal Class I, II, and III relationships. Anatomic parameters were measured using a three-dimensional post-processing console: the thickness of the maxillary and palatine bones as well as the alveolar crest, maxillary body and sutural length, width and height of the hard palate, maxillary facial wall thickness, and masseter muscle thickness and length. RESULTS Individuals with brachyfacial configurations had a significantly increased palatal and alveolar ridge thicknesses compared to those with dolichofacial- or mesofacial configurations. Brachyfacial configurations presented a significantly increased length and thickness of the masseter muscle (4.599 cm; 1.526 cm) than mesofacial (4.431 cm; 1.466 cm) and dolichofacial configurations (4.405 cm; 1.397 cm) (p < 0.001). Individuals with a skeletal Class III had a significantly shorter palatal length (5.313 cm) than those with Class I (5.406 cm) and Class II (5.404 cm) (p < 0.01). Sutural length was also significantly shorter in Class III (p < 0.05). CONCLUSIONS Skeletal configurations have an impact on parameters of the bony skull. Also, measurable adaptations of the muscular phenotype could result. CLINICAL RELEVANCE The association between viscerocranial morphology and midface anatomy might be beneficial for tailoring orthodontic appliances to individual anatomy and planning cortically anchored orthodontic appliances.
Collapse
|
6
|
Iterative Metal Artifact Reduction in Head and Neck CT Facilitates Tumor Visualization of Oral and Oropharyngeal Cancer Obscured by Artifacts From Dental Hardware. Acad Radiol 2023; 30:2962-2972. [PMID: 37179206 DOI: 10.1016/j.acra.2023.04.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 04/02/2023] [Accepted: 04/07/2023] [Indexed: 05/15/2023]
Abstract
RATIONALE AND OBJECTIVES The purpose of this study was to evaluate the diagnostic utility of iterative metal artifact reduction (iMAR) in computed tomography (CT)-imaging of oral and oropharyngeal cancers when obscured by dental hardware artifacts and to determine the most appropriate iMAR settings for this purpose. MATERIALS AND METHODS The study retrospectively enrolled 27 patients (8 female, 19 male; mean age 64±12.7years) with histologically confirmed oral or oropharyngeal cancer obscured by dental artifacts in contrast-enhanced CT. Raw CT data were reconstructed with ascending iMAR strengths (levels 1/2/3/4/5) and one reconstruction without iMAR (level 0). For subjective analysis, two blinded radiologists rated tumor visualization and artifact severity on a five-point Likert scale. For objective analysis, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and artifact index (AI) were determined. RESULTS iMAR reconstructions improved the subjective image quality of tumor edge and contrast, and the objective parameters of tumor SNR and CNR, reaching their optimum at iMAR levels 4 and 5 (P<.001). AI decreased with iMAR reconstructions reaching its minimum at iMAR level 5 (P<.001). Tumor detection rates increased 2.4-fold with iMAR 5, 2.1-fold with iMAR 4, and 1.9-fold with iMAR 3 compared to reconstructions without iMAR. Disadvantages such as algorithm-induced artifacts increased significantly with higher iMAR strengths (P<.05), reaching a maximum with iMAR 5. CONCLUSION iMAR significantly improves CT imaging of oral and oropharyngeal cancers, as confirmed by both subjective and objective measures, with best results at highest iMAR strengths.
Collapse
|
7
|
Diagnostic Accuracy and Performance Analysis of a Scanner-Integrated Artificial Intelligence Model for the Detection of Intracranial Hemorrhages in a Traumatology Emergency Department. Bioengineering (Basel) 2023; 10:1362. [PMID: 38135956 PMCID: PMC10740704 DOI: 10.3390/bioengineering10121362] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 11/03/2023] [Accepted: 11/19/2023] [Indexed: 12/24/2023] Open
Abstract
Intracranial hemorrhages require an immediate diagnosis to optimize patient management and outcomes, and CT is the modality of choice in the emergency setting. We aimed to evaluate the performance of the first scanner-integrated artificial intelligence algorithm to detect brain hemorrhages in a routine clinical setting. This retrospective study includes 435 consecutive non-contrast head CT scans. Automatic brain hemorrhage detection was calculated as a separate reconstruction job in all cases. The radiological report (RR) was always conducted by a radiology resident and finalized by a senior radiologist. Additionally, a team of two radiologists reviewed the datasets retrospectively, taking additional information like the clinical record, course, and final diagnosis into account. This consensus reading served as a reference. Statistics were carried out for diagnostic accuracy. Brain hemorrhage detection was executed successfully in 432/435 (99%) of patient cases. The AI algorithm and reference standard were consistent in 392 (90.7%) cases. One false-negative case was identified within the 52 positive cases. However, 39 positive detections turned out to be false positives. The diagnostic performance was calculated as a sensitivity of 98.1%, specificity of 89.7%, positive predictive value of 56.7%, and negative predictive value (NPV) of 99.7%. The execution of scanner-integrated AI detection of brain hemorrhages is feasible and robust. The diagnostic accuracy has a high specificity and a very high negative predictive value and sensitivity. However, many false-positive findings resulted in a relatively moderate positive predictive value.
Collapse
|
8
|
Deep Learning and Registration-Based Mapping for Analyzing the Distribution of Nodal Metastases in Head and Neck Cancer Cohorts: Informing Optimal Radiotherapy Target Volume Design. Cancers (Basel) 2023; 15:4620. [PMID: 37760588 PMCID: PMC10526893 DOI: 10.3390/cancers15184620] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2023] [Revised: 09/15/2023] [Accepted: 09/15/2023] [Indexed: 09/29/2023] Open
Abstract
We introduce a deep-learning- and a registration-based method for automatically analyzing the spatial distribution of nodal metastases (LNs) in head and neck (H/N) cancer cohorts to inform radiotherapy (RT) target volume design. The two methods are evaluated in a cohort of 193 H/N patients/planning CTs with a total of 449 LNs. In the deep learning method, a previously developed nnU-Net 3D/2D ensemble model is used to autosegment 20 H/N levels, with each LN subsequently being algorithmically assigned to the closest-level autosegmentation. In the nonrigid-registration-based mapping method, LNs are mapped into a calculated template CT representing the cohort-average patient anatomy, and kernel density estimation is employed to estimate the underlying average 3D-LN probability distribution allowing for analysis and visualization without prespecified level definitions. Multireader assessment by three radio-oncologists with majority voting was used to evaluate the deep learning method and obtain the ground-truth distribution. For the mapping technique, the proportion of LNs predicted by the 3D probability distribution for each level was calculated and compared to the deep learning and ground-truth distributions. As determined by a multireader review with majority voting, the deep learning method correctly categorized all 449 LNs to their respective levels. Level 2 showed the highest LN involvement (59.0%). The level involvement predicted by the mapping technique was consistent with the ground-truth distribution (p for difference 0.915). Application of the proposed methods to multicenter cohorts with selected H/N tumor subtypes for informing optimal RT target volume design is promising.
Collapse
|
9
|
Free-Breathing and Single-Breath Hold Compressed Sensing Real-Time MRI of Right Ventricular Function in Children with Congenital Heart Disease. Diagnostics (Basel) 2023; 13:2403. [PMID: 37510147 PMCID: PMC10377861 DOI: 10.3390/diagnostics13142403] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 06/26/2023] [Accepted: 07/14/2023] [Indexed: 07/30/2023] Open
Abstract
(1) Purpose: to compare right ventricular (RV) functional parameters in children with surgically repaired congenital heart disease (CHD) using single/double breath hold (BH) and free-breathing (FB) real-time compressed sensing (CS) cine cardiac magnetic resonance (cMRI) with standard retrospective segmented multi breath hold (RMB) cine cMRI. (2) Methods: Twenty patients with CHD underwent BH and FB, as well as RMB cine cMRI, at 3T to obtain a stack of continuous axial images of the RV. Two radiologists independently performed qualitative analysis of the image quality (rated on a 5-point scale; 1 = non-diagnostic to 5 = excellent) and quantitative analysis of the RV volume measurements. (3) Results: The best image quality was provided by RMB (4.5; range 2-5) compared to BH (3.9; range 3-5; p = 0.04) and FB (3.6; range 3-5; p < 0.01). The RV functional parameters were comparable among BH, FB, and RMB with a difference of less than 5%. The scan times for BH (44 ± 38 s, p < 0.01) and FB (24 ± 7 s, p < 0.01) were significantly reduced compared to for RMB (261 ± 68 s). (4) Conclusions: CS-FB and CS-BH real-time cine cMRI in children with CHD provides diagnostic image quality with excellent accuracy for measuring RV function with a significantly reduced scan time compared to RMB.
Collapse
|
10
|
Comparison of Diagnostic Performance and Image Quality between Topup-Corrected and Standard Readout-Segmented Echo-Planar Diffusion-Weighted Imaging for Cholesteatoma Diagnostics. Diagnostics (Basel) 2023; 13:diagnostics13071242. [PMID: 37046460 PMCID: PMC10093611 DOI: 10.3390/diagnostics13071242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 03/14/2023] [Accepted: 03/16/2023] [Indexed: 03/29/2023] Open
Abstract
This study compares the diagnostic performance and image quality of single-shot turbo spin-echo DWI (tseDWI), standard readout-segmented DWI (rsDWI), and a modified rsDWI version (topupDWI) for cholesteatoma diagnostics. Thirty-four patients with newly suspected unilateral cholesteatoma were examined on a 1.5 Tesla MRI scanner. Diagnostic performance was evaluated by calculating and comparing the sensitivity and specificity using histopathological results as the standard of reference. Image quality was independently reviewed by two readers using a 5-point Likert scale evaluating image distortions, susceptibility artifacts, image resolution, lesion conspicuity, and diagnostic confidence. Twenty-five cholesteatomas were histologically confirmed after surgery and originated in the study group. TseDWI showed the highest sensitivity with 96% (95% confidence interval (CI): 88–100%), followed by topupDWI with 92% (95% CI: 81–100%) for both readers. The sensitivity for rsDWI was 76% (95% CI: 59–93%) for reader 1 and 84% (95% CI: 70–98%) for reader 2, respectively. Both tseDWI and topupDWI revealed a specificity of 100% (95% CI: 66–100%) and rsDWI of 89% (95% CI: 52–100%). Both tseDWI and topupDWI showed fewer image distortions and susceptibility artifacts compared to rsDWI. Image resolution was consistently rated best for topupDWI, followed by rsDWI, which both outperformed tseDWI. TopupDWI and tseDWI showed comparable results for lesions’ conspicuity and diagnostic confidence, both outperforming rsDWI. Modified readout-segmented DWI using the topup-correction method is preferable to standard rsDWI and may be regarded as an accurate alternative to single-shot turbo spin-echo DWI in cholesteatoma diagnostics.
Collapse
|
11
|
Cor Triatriatum Sinistrum Combined with Changes in Atrial Septum and Right Atrium in a 60-Year-Old Woman. MEDICINA-LITHUANIA 2021; 57:medicina57080777. [PMID: 34440984 PMCID: PMC8402230 DOI: 10.3390/medicina57080777] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Revised: 07/27/2021] [Accepted: 07/28/2021] [Indexed: 11/16/2022]
Abstract
Background and Objectives: A rare case of cor triatriatum sinistrum in combination with anomalies in the atrial septum and in the right atrium of a 60-year-old female body donor is described here. Materials and Methods: In addition to classical dissection, ultrasound and magnetic resonance imaging, computer tomography and cinematic rendering were performed. In a reference series of 59 regularly formed hearts (33 men, 26 women), we looked for features in the left and right atrium or atrial septum. In addition, we measured the atrial and ventricular wall thickness in 15 regularly formed hearts (7 men, 8 women). Results: In the case described, the left atrium was partly divided into two chambers by an intra-atrial membrane penetrated by two small openings. The 2.5 cm-high membrane originated in the upper level of the oval fossa and left an opening of about 4 cm in diameter. Apparently, the membrane did not lead to a functionally significant flow obstruction due to the broad intra-atrial communication between the proximal and distal chamber of the left atrium. In concordance with this fact, left atrial wall thickness was not elevated in the cor triatriatum sinistrum when compared with 15 regularly formed hearts. In addition, two further anomalies were found: 1. the oval fossa was deepened and arched in the direction of the left atrium; 2. the right atrium showed a membrane-like structure at its posterior and lateral walls, which began at the lower edge of the oval fossa. It probably corresponds to a strongly developed eustachian valve (valve of the inferior vena cava). Conclusions: The case described suggests that malformations in the development of the atrial septum and in the regression of the valve of the right sinus vein are involved in the pathogenesis of cor triatriatum sinistrum.
Collapse
|
12
|
Cutting Staff Radiation Exposure and Improving Freedom of Motion during CT Interventions: Comparison of a Novel Workflow Utilizing a Radiation Protection Cabin versus Two Conventional Workflows. Diagnostics (Basel) 2021; 11:diagnostics11061099. [PMID: 34208499 PMCID: PMC8235446 DOI: 10.3390/diagnostics11061099] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2021] [Revised: 06/10/2021] [Accepted: 06/12/2021] [Indexed: 01/05/2023] Open
Abstract
This study aimed to evaluate the radiation exposure to the radiologist and the procedure time of prospectively matched CT interventions implementing three different workflows—the radiologist—(I) leaving the CT room during scanning; (II) wearing a lead apron and staying in the CT room; (III) staying in the CT room in a prototype radiation protection cabin without lead apron while utilizing a wireless remote control and a tablet. We prospectively evaluated the radiologist’s radiation exposure utilizing an electronic personal dosimeter, the intervention time, and success in CT interventions matched to the three different workflows. We compared the interventional success, the patient’s dose of the interventional scans in each workflow (total mAs and total DLP), the radiologist’s personal dose (in µSV), and interventional time. To perform workflow III, a prototype of a radiation protection cabin, with 3 mm lead equivalent walls and a foot switch to operate the doors, was built in the CT examination room. Radiation exposure during the maximum tube output at 120 kV was measured by the local admission officials inside the cabin at the same level as in the technician’s control room (below 0.5 μSv/h and 1 mSv/y). Further, to utilize the full potential of this novel workflow, a sterile packed remote control (to move the CT table and to trigger the radiation) and a sterile packed tablet anchored on the CT table (to plan and navigate during the CT intervention) were operated by the radiologist. There were 18 interventions performed in workflow I, 16 in workflow II, and 27 in workflow III. There were no significant differences in the intervention time (workflow I: 23 min ± 12, workflow II: 20 min ± 8, and workflow III: 21 min ± 10, p = 0.71) and the patient’s dose (total DLP, p = 0.14). However, the personal dosimeter registered 0.17 ± 0.22 µSv for workflow II, while I and III both documented 0 µSv, displaying significant difference (p < 0.001). All workflows were performed completely and successfully in all cases. The new workflow has the potential to reduce interventional CT radiologists’ radiation dose to zero while relieving them from working in a lead apron all day.
Collapse
|
13
|
Comparison of Readout-Segmented Echo-Planar Imaging and Single-Shot TSE DWI for Cholesteatoma Diagnostics. AJNR Am J Neuroradiol 2021; 42:1305-1312. [PMID: 33926901 DOI: 10.3174/ajnr.a7112] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2020] [Accepted: 01/23/2021] [Indexed: 01/18/2023]
Abstract
BACKGROUND AND PURPOSE The high diagnostic value of DWI for cholesteatoma diagnostics is undisputed. This study compares the diagnostic value of readout-segmented echo-planar DWI and single-shot TSE DWI for cholesteatoma diagnostics. MATERIALS AND METHODS Thirty patients with newly suspected cholesteatoma were examined with a dedicated protocol, including readout-segmented echo-planar DWI and single-shot TSE DWI at 1.5T. Acquisition parameters of both diffusion-weighted sequences were as follows: b=1000 s/mm,2 axial and coronal section orientations, and section thickness of 3 mm. Image quality was evaluated by 2 readers on a 5-point Likert scale with respect to lesion conspicuity, the presence of susceptibility artifacts mimicking cholesteatomas, and overall subjective image quality. Sensitivity and specificity were calculated using histology results as the gold standard. RESULTS Twenty-five cases of histologically confirmed cholesteatomas were included in the study group. Lesion conspicuity was higher and fewer artifacts were found when using TSE DWI (both P < .001). The overall subjective image quality, however, was better with readout-segmented DWI. For TSE DWI, the sensitivity for readers 1 and 2 was 92% (95% CI, 74%-99%) and 88% (95% CI, 69%-97%), respectively, while the specificity for both readers was 80% (95% CI, 28%-99%). For readout-segmented DWI, the sensitivity for readers 1 and 2 was 76% (95% CI, 55%-91%) and 68% (95% CI, 46%-85%), while the specificity for both readers was 60% (95% CI, 15%-95%). CONCLUSIONS The use of TSE DWI is advisable for cholesteatoma diagnostics and preferable over readout-segmented DWI.
Collapse
|
14
|
Potential for Radiation Dose Reduction in Dual-Source Computed Tomography of the Lung in the Pediatric and Adolescent Population Compared to Digital Radiography. Diagnostics (Basel) 2021; 11:diagnostics11020270. [PMID: 33578643 PMCID: PMC7916398 DOI: 10.3390/diagnostics11020270] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 02/01/2021] [Accepted: 02/05/2021] [Indexed: 12/12/2022] Open
Abstract
Low-dose dual-source computed tomography (DSCT) protocols for the evaluation of lung diseases in children and adolescents are of importance since this age group is particularly prone to radiation damage. The aim of this study was to evaluate image quality of low-dose DSCT of the lung and to assess the potential of radiation dose reduction compared to digital radiographs (DR). Three groups, each consisting of 19 patients, were examined with different DSCT protocols using tin prefiltration (Sn96/64/32 ref. mAs at 100 kV). Different strengths of iterative reconstruction were applied (ADMIRE 2/3/4). DSCT groups were compared to 19 matched patients examined with posterior–anterior DR. Diagnostic confidence, detectability of anatomical structures and small lung lesions were evaluated on a 4-point Likert scale (LS 1 = unacceptable, 4 = fully acceptable; a value ≥ 3 was considered acceptable). Effective dose (ED) was 31-/21-/9-fold higher in Sn96/Sn64/Sn32 compared to DR. Diagnostic confidence was sufficient in Sn96/Sn64 (LS 3.4/3.2), reduced in Sn32 (LS 2.7) and the worst in DR (LS 2.4). In DSCT, detectability of small anatomical structures was always superior to DR (p < 0.05). Mean lesion size ranged from 5.1–7 mm; detectability was acceptable in all DSCT groups (LS 3.0–3.4) and superior to DR (LS 1.9; p < 0.05). Substantial dose lowering in DSCT of the pediatric lung enables acceptable detectability of small lung lesions with a radiation dose being about 10-fold higher compared to DR.
Collapse
|
15
|
Structured Digital Self-Assessment of Patient Anamnesis Prior to Computed Tomography: Performance Evaluation and Added Value. J Med Syst 2021; 45:30. [PMID: 33511485 PMCID: PMC7843739 DOI: 10.1007/s10916-020-01690-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Accepted: 12/01/2020] [Indexed: 01/02/2023]
Abstract
The aim of this study was to evaluate the performance of a tablet-based, digitized structured self-assessment (DSSA) of patient anamnesis (PA) prior to computed tomography (CT). Of the 317 patients consecutively referred for CT, the majority (n = 294) was able to complete the tablet-based questionnaire, which consisted of 67 items covering social anamnesis, lifestyle factors (e.g., tobacco abuse), medical history (e.g., kidney diseases), current symptoms, and the usability of the system. Patients were able to mark unclear questions for a subsequent discussion with the radiologist. Critical issues for the CT examination were structured and automatically highlighted as “red flags” (RFs) in order to improve patient interaction. RFs and marked questions were highly prevalent (69.5% and 26%). Missing creatinine values (33.3%), kidney diseases (14.4%), thyroid diseases (10.6%), metformin (5.5%), claustrophobia (4.1%), allergic reactions to contrast agents (2.4%), and pathological TSH values (2.0%) were highlighted most frequently as RFs. Patient feedback regarding the comprehensibility of the questionnaire and the tablet usability was mainly positive (90.9%; 86.2%). With advanced age, however, patients provided more negative feedback for both (p = 0.007; p = 0.039). The time effort was less than 20 min for 85.1% of patients, and faster patients were significantly younger (p = 0.046). Overall, the DSSA of PA prior to CT shows a high success rate and is well accepted by most patients. RFs and marked questions were common and helped to focus patients’ interactions and reporting towards decisive aspects.
Collapse
|
16
|
Personalized computed tomography - Automated estimation of height and weight of a simulated digital twin using a 3D camera and artificial intelligence. ROFO-FORTSCHR RONTG 2020; 193:437-445. [PMID: 33142337 DOI: 10.1055/a-1253-8558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
PURPOSE The aim of this study was to develop an algorithm for automated estimation of patient height and weight during computed tomography (CT) and to evaluate its accuracy in everyday clinical practice. MATERIALS AND METHODS Depth images of 200 patients were recorded with a 3D camera mounted above the patient table of a CT scanner. Reference values were obtained using a calibrated scale and a measuring tape to train a machine learning algorithm that fits a patient avatar into the recorded patient surface data. The resulting algorithm was prospectively used on 101 patients in clinical practice and the results were compared to the reference values and to estimates by the patient himself, the radiographer and the radiologist. The body mass index was calculated from the collected values for each patient using the WHO formula. A tolerance level of 5 kg was defined in order to evaluate the impact on weight-dependent contrast agent dosage in abdominal CT. RESULTS Differences between values for height, weight and BMI were non-significant over all assessments (p > 0.83). The most accurate values for weight were obtained from the patient information (R² = 0.99) followed by the automated estimation via 3D camera (R² = 0.89). Estimates by medical staff were considerably less precise (radiologist: R² = 0.78, radiographer: R² = 0.77). A body-weight dependent dosage of contrast agent using the automated estimations matched the dosage using the reference measurements in 65 % of the cases. The dosage based on the medical staff estimates would have matched in 49 % of the cases. CONCLUSION Automated estimation of height and weight using a digital twin model from 3D camera acquisitions provide a high precision for protocol design in computer tomography. KEY POINTS · Machine learning can calculate patient-avatars from 3D camera acquisitions.. · Height and weight of the digital twins are comparable to real measurements of the patients.. · Estimations by medical staff are less precise.. · The values can be used for calculation of contrast agent dosage.. CITATION FORMAT · Geissler F, Heiß R, Kopp M et al. Personalized computed tomography - Automated estimation of height and weight of a simulated digital twin using a 3D camera and artificial intelligence. Fortschr Röntgenstr 2021; 193: 437 - 445.
Collapse
|
17
|
Achieving high spatial and temporal resolution with perfusion MRI in the head and neck region using golden-angle radial sampling. Eur Radiol 2020; 31:2263-2271. [PMID: 32970184 PMCID: PMC7979632 DOI: 10.1007/s00330-020-07263-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Revised: 07/21/2020] [Accepted: 09/04/2020] [Indexed: 12/02/2022]
Abstract
Objectives Conventional perfusion-weighted MRI sequences often provide poor spatial or temporal resolution. We aimed to overcome this problem in head and neck protocols using a golden-angle radial sparse parallel (GRASP) sequence. Methods We prospectively included 58 patients for examination on a 3.0-T MRI using a study protocol. GRASP (A) was applied to a volumetric interpolated breath-hold examination (VIBE) with 135 reconstructed pictures and high temporal (2.5 s) and spatial resolution (0.94 × 0.94 × 3.00 mm). Additional sequences of matching temporal resolution (B: 2.5 s, 1.88 × 1.88 × 3.00 mm), with a compromise between temporal and spatial resolution (C: 7.0 s, 1.30 × 1.30 × 3.00 mm) and with matching spatial resolution (D: 145 s, 0.94 × 0.94 × 3.00 mm), were subsequently without GRASP. Instant inline-image reconstructions (E) provided one additional series of averaged contrast information throughout the entire acquisition duration of A. Overall diagnostic image quality, edge sharpness and contrast of soft tissues, vessels and lesions were subjectively rated using 5-point Likert scales. Objective image quality was measured as contrast-to-noise ratio in D and E. Results Overall, the anatomic and pathologic image quality was substantially better with the GRASP sequence for the temporally (A/B/C, all p < 0.001) and spatially resolved comparisons (D/E, all p < 0.002 except lesion edge sharpness with p = 0.291). Image artefacts were also less likely to occur with GRASP. Differences in motion, aliasing and truncation were mainly significant, but pulsation and fat suppression were comparable. In addition, the contrast-to-noise ratio of E was significantly better than that of D (pD-E < 0.001). Conclusions High temporal and spatial resolution can be obtained synchronously using a GRASP-VIBE technique for perfusion evaluation in head and neck MRI. Key Points • Golden-angle radial sparse parallel (GRASP) sampling allows for temporally resolved dynamic acquisitions with a very high image quality. • Very low-contrast structures in the head and neck region can benefit from using the GRASP sequence. • Inline-image reconstruction of dynamic and static series from one single acquisition can replace the conventional combination of two acquisitions, thereby saving examination time. Electronic supplementary material The online version of this article (10.1007/s00330-020-07263-0) contains supplementary material, which is available to authorized users.
Collapse
|
18
|
Effect of long term CPAP therapy on cardiac parameters assessed with cardiac MRI. Int J Cardiovasc Imaging 2020; 37:613-621. [PMID: 32926309 PMCID: PMC8423704 DOI: 10.1007/s10554-020-02024-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/22/2020] [Accepted: 09/09/2020] [Indexed: 11/16/2022]
Abstract
The obstructive sleep apnoea syndrome (OSAS) is a disorder with a high prevalence and is associated with an elevated cardiovascular risk and increased morbidity and mortality. For longitudinal studies and functional analysis cardiac MRI is regarded as the gold standard. Aim of this study was to evaluate the long-term effect of continuous positive airway pressure (CPAP) therapy on cardiac functional parameters with cardiac Magnetic Resonance Imaging (cMRI). 54 patients with OSAS (mean apnea hypopnea index-AHI: 31) were prospectively enrolled in this study and cMRI was performed before and after 7 months of CPAP therapy. Data were acquired on a 1.5 T MRI and right and left ventricular cardiac function were analysed. CPAP treatment was considered compliant when used ≥ 4 h per night. 24-h blood pressure was measured at baseline and follow up. 33 patients could be assigned to the compliance group. Left ventricular stroke volume (LV SV) and right ventricular ejection fraction (RV EF) improved significantly with CPAP therapy (LV SV from 93 ± 19 to 99 ± 20 ml, p = 0.02; RV EF from 50 ± 6 to 52 ± 6%, p = 0.04). All other cardiac parameters did not change significantly while mean systolic and diastolic blood pressure improved significantly (p < 0.01). 21 patients were assigned to the non-compliance group and were considered as a control group. There were no relevant differences in cardiac parameters between baseline and follow up examination in these patients. CPAP therapy seems to improve LV SV, RV EF, systolic and diastolic blood pressure in OSAS patients, but reproducibility of our results need to be confirmed in a larger patient population.
Collapse
|
19
|
Cardiac T2 mapping: robustness and homogeneity of standardized in-line analysis. J Cardiovasc Magn Reson 2020; 22:39. [PMID: 32460852 PMCID: PMC7254724 DOI: 10.1186/s12968-020-00619-x] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2019] [Accepted: 03/23/2020] [Indexed: 01/22/2023] Open
Abstract
BACKGROUND AND PURPOSE Interpretation of T2 values remains difficult due to limited comparability across hardware and software systems and the lack of validated measurement recommendations for the number and orientation of mandatory slices. Our aims were to provide a standardized comparison of intra- and inter-individual T2 values in the short and long axes and to investigate inter-scanner reproducibility. METHOD AND MATERIALS Ninety cardiovascular magnetic resonance (CMR) studies in 30 healthy subjects were performed with three identical 1.5 T CMR scanners (same hardware and software) using a balanced steady-state free precession (bSSFP) gradient echo sequence in three short axis (SAx) and three long axis (LAx) views. A commercially available T2 mapping software package of the latest generation with automatic in-line motion correction was used for acquisition. Regions of interest were manually drawn in each of the 16 myocardial segments according to the American Heart Association (AHA) model in three SAx and three LAx acquisitions. Analysis of inter-scanner, inter-segmental, intra-segmental, inter-regional and inter-level differences was performed. RESULTS Inter-scanner reproducibility was high and the mean myocardial T2 value for all evaluated segments was 45.7 ± 3.4 ms. Significant inter-segmental variations of mean T2 values were found. Mean intra-segmental T2 values were comparable between LAx and SAx acquisitions in 72%. Significantly higher T2 values were found in apical segments and a significant disparity among different regions was found for SAx and LAx orientations. CONCLUSION Standardized cardiac T2 mapping is highly reproducible on identical CMR systems. T2 values vary significantly between single heart segments, regions, levels, and axes in young, healthy subjects.
Collapse
|
20
|
Abstract
A CT system with a tablet as mobile user interface and a wireless remote control for positioning and radiation release has recently been presented. Our aim was to evaluate the effects of a mobile CT examination workflow on the radiographers’ performance compared to conventional examinations. A prototype of a radiation protection cabin was installed besides the gantry of a CT system. The CT system was equipped with a simplified user interface on a portable tablet and a mobile remote control. 98 patients with an indication for CT of the chest were randomly assigned to examination using the mobile devices (study group, n = 47) or using the conventional stationary workflow on the console (reference group, n = 51). Three ceiling mounted fisheye cameras were used for motion tracking of the radiographers, two in the examination room and one in the control room. Relative density of detection heat-maps and area counts were assessed using a dedicated software tool to quantify radiographers’ movements. Duration of each task of the examination was manually recorded using a stopwatch. In the reference group 25% of the area counts were located inside of the examination room, while it was 48% in the study group. The time spent in the same room with the patient increased from 3:06 min (29%) to 6:01 min (57%) using the mobile workflow (p < 0.05), thereof 0:59 min (9%) were spent in moderate separation with maintained voice and visual contact in the radiation protection cabin. Heat-maps showed an increase of the radiographer’s working area, indicating a higher freedom of movement. Total duration of the examination was slightly less in the study group without statistical significance (median time: study 10:36, reference 10:50 min; p = 0.29). A mobile CT examination transfers the radiographers’ interaction with the scanner from the control room into the examination room. There, radiographers’ freedom of movement is higher, without any tradeoffs regarding the examination duration.
Collapse
|
21
|
Extent of simultaneous radiation dose and iodine reduction at stable image quality in computed tomography of the chest: A systematic approach using automated tube voltage adaption and iterative reconstructions. Medicine (Baltimore) 2018; 97:e0388. [PMID: 29642199 PMCID: PMC5908636 DOI: 10.1097/md.0000000000010388] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
BACKGROUND Aim of this study was to systematically combine tube voltage adaptation and iterative reconstructions for reduction of iodine and radiation dose. METHODS Settings for the study protocol were evaluated in ex-ante trials to provide image quality that is comparable to a reference protocol at 120 kV with tube current modulation. Consecutive patients were randomized to undergo computed tomography (CT) of the chest using the study protocol (n = 62) or reference protocol (n = 50). Objective and subjective image quality was assessed and compared. RESULTS Tube voltage was decreased to 100 kV in 47 patients and to 80 kV in 15 patients in the study group. The iodine dosage (16.1 vs 10.5 g) and the effective radiation dose (3.6 vs 2.5 mSv) were significantly decreased in the study group (both P < .001). Contrast-to-noise ratio was comparable in the pulmonary trunk and increased in the aorta (P < .01). Subjective image quality was comparable without statistically significance. CONCLUSIONS Simultaneous reductions in iodine dosage and radiation dose by one-third are feasible for CT of the chest.
Collapse
|
22
|
Cardiac MRI in Children and Adolescents Who Have Undergone Surgical Repair of Right-Sided Congenital Heart Disease: Automated Left Ventricular Volumes and Function Analysis and Effects of Different Manual Adjustments. ROFO-FORTSCHR RONTG 2015; 187:1099-107. [PMID: 26327669 DOI: 10.1055/s-0035-1553418] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
PURPOSE To evaluate automated segmentation and the effects of different manual adjustments regarding left ventricular parameter quantification in cardiac magnetic resonance (MR) data on children and adolescents who have undergone surgical repair of right-sided congenital heart disease (CHD). MATERIALS AND METHODS Dedicated software (syngo.via, Siemens AG) was used to automatically segment and/or manually adjust the end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), myocardial mass (MM) and ejection fraction (EF) before/after manual apex/base adjustment (ADJ-step 1) and after manual apex/base/myocardial contour adjustment (ADJ-step 2; reference standard). MR data of 40 patients (13.1 ± 3. y, 4 - 17 y) with repaired CHD with decreased pulmonary blood flow (CHD-DPBF) were evaluated. Intra- and inter-rater reliability was determined for 10 randomly selected patients. RESULTS The software correctly detected the left ventricle in 38/40 (95%) patients. EDV after automated segmentation: 119.1 ± 44.0 ml; after ADJ-step 1: 115.8 ± 9.5 ml; after ADJ-step 2: 116.2 ± 39.4 ml. The corresponding results for ESV were 52.0 ± 18.5/49.6 ± 6.9/49.7 ± 16.4 ml; for SV 67.1 ± 28.5/66.2 ± 25.4/66.5 ± 25. ml; for EF 55.5 ± 7.3/56.7 ± 6.6/56.7 ± 6.3%; for MM 83.7 ± 35.9/76.2 ± 8.3/74.6 ± 27.2 g. Significant differences were found for ESV/MM/EF comparing the automated segmentation results with these after ADJ-step 1 and ADJ-step 2. No significant differences were found when comparing all results of ADJ-step 1 and ADJ-step 2 or when comparing EDV/SV results. Intra- and inter-rater reliability was excellent. The mean time effort was 63.4 ± 6.9 s for the automated segmentation, 74.2 ± 8.9 s for ADJ-step 1 and 269.5 ± 39.4 s for ADJ-step 2. CONCLUSION Automated left ventricular volumes and function analysis in children and adolescents with surgically treated CHD proved to be feasible with excellent intra- and inter-rater reliability. Automated segmentation with manual apex/base adjustment provided clinically acceptable results. KEY POINTS Automated left ventricular volume and function analysis in children and adolescents with surgically treated right-sided heart disease is feasible with excellent intra- and inter-rater reliability. Automated segmentation with manual apex/base adjustment provides clinically acceptable results. Additional manual myocardial contour adjustment does not significantly improve the results.
Collapse
|
23
|
Improved Image Quality in Head and Neck CT Using a 3D Iterative Approach to Reduce Metal Artifact. AJNR Am J Neuroradiol 2015; 36:1988-93. [PMID: 26272971 DOI: 10.3174/ajnr.a4386] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2014] [Accepted: 02/09/2015] [Indexed: 02/02/2023]
Abstract
BACKGROUND AND PURPOSE Metal artifacts from dental fillings and other devices degrade image quality and may compromise the detection and evaluation of lesions in the oral cavity and oropharynx by CT. The aim of this study was to evaluate the effect of iterative metal artifact reduction on CT of the oral cavity and oropharynx. MATERIALS AND METHODS Data from 50 consecutive patients with metal artifacts from dental hardware were reconstructed with standard filtered back-projection, linear interpolation metal artifact reduction (LIMAR), and iterative metal artifact reduction. The image quality of sections that contained metal was analyzed for the severity of artifacts and diagnostic value. RESULTS A total of 455 sections (mean ± standard deviation, 9.1 ± 4.1 sections per patient) contained metal and were evaluated with each reconstruction method. Sections without metal were not affected by the algorithms and demonstrated image quality identical to each other. Of these sections, 38% were considered nondiagnostic with filtered back-projection, 31% with LIMAR, and only 7% with iterative metal artifact reduction. Thirty-three percent of the sections had poor image quality with filtered back-projection, 46% with LIMAR, and 10% with iterative metal artifact reduction. Thirteen percent of the sections with filtered back-projection, 17% with LIMAR, and 22% with iterative metal artifact reduction were of moderate image quality, 16% of the sections with filtered back-projection, 5% with LIMAR, and 30% with iterative metal artifact reduction were of good image quality, and 1% of the sections with LIMAR and 31% with iterative metal artifact reduction were of excellent image quality. CONCLUSIONS Iterative metal artifact reduction yields the highest image quality in comparison with filtered back-projection and linear interpolation metal artifact reduction in patients with metal hardware in the head and neck area.
Collapse
|
24
|
Thoracic non-osseous lesions in cancer patients detected in low-dose CT images acquired as part of skeletal SPECT/CT examinations. Nuklearmedizin 2015; 54:173-7. [PMID: 26165684 DOI: 10.3413/nukmed-0721-15-02] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2015] [Accepted: 06/28/2015] [Indexed: 12/21/2022]
Abstract
AIM Hybrid single-photon emission tomographic (SPECT) and X-ray computed tomography (CT) systems are increasingly used in oncologic imaging. With SPECT/CT not only the thoracic spine but also the surrounding soft tissue needs to be evaluated for pathological findings. The purpose of this study was to assess the prevalence of non-osseous findings detectable on low-dose CT datasets from patients studied by thoracic 99mTc-dicarboxypropane diphosphonate (DPD)-SPECT/CT. PATIENTS, METHODS 119 consecutive oncologic patients (81 breast cancer, 38 with other cancer) who underwent DPD-SPECT CT of the thoracic region were included in this study. Non-osseous findings on CT were classified as either probably benign or suspicious. Suspicious findings were correlated with retrievable previous imaging and if performed with follow up imaging (MRI, CT with contrast medium, Ultrasound) or biopsy results. RESULTS In 80/119 (67%) patients no imaging was performed before SPECT/CT. Only 7/119 subjects (6%) had no other lesions than bone lesions. In 101/119 (85%) patients lesions found on SPECT/CT images were rated as benign and in 65/119 (55%) patients as suspicious. In 8/119 (7%) patients with previously unknown suspicious lesions on SPECT/CT images suspicious findings were confirmed by biopsy. CONCLUSION 7% of patients referred to SPECT/CT of the thoracic spine for staging of malignant disease had previously unknown suspicious non-osseous lesions detectable on the low-dose CT images which were confirmed by biopsy. This could be especially relevant for cancer entities like breast and prostate, in which no thorax-CT is routinely intended for staging.
Collapse
|
25
|
Imaging the Parasinus Region with a Third-Generation Dual-Source CT and the Effect of Tin Filtration on Image Quality and Radiation Dose. AJNR Am J Neuroradiol 2015; 36:1225-30. [PMID: 25814658 DOI: 10.3174/ajnr.a4270] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2014] [Accepted: 12/14/2014] [Indexed: 12/16/2022]
Abstract
BACKGROUND AND PURPOSE CT is the imaging technique of choice in the evaluation of midface trauma or inflammatory disease. We performed a systematic evaluation of scan protocols to optimize image quality and radiation exposure on third-generation dual-source CT. MATERIALS AND METHODS CT protocols with different tube voltage (70-150 kV), current (25-300 reference mAs), prefiltration, pitch value, and rotation time were systematically evaluated. All images were reconstructed with iterative reconstruction (Advanced Modeled Iterative Reconstruction, level 2). To individually compare results with otherwise identical factors, we obtained all scans on a frozen human head. Conebeam CT was performed for image quality and dose comparison with multidetector row CT. Delineation of important anatomic structures and incidental pathologic conditions in the cadaver head was evaluated. RESULTS One hundred kilovolts with tin prefiltration demonstrated the best compromise between dose and image quality. The most dose-effective combination for trauma imaging was Sn100 kV/250 mAs (volume CT dose index, 2.02 mGy), and for preoperative sinus surgery planning, Sn100 kV/150 mAs (volume CT dose index, 1.22 mGy). "Sn" indicates an additional prefiltration of the x-ray beam with a tin filter to constrict the energy spectrum. Exclusion of sinonasal disease was possible with even a lower dose by using Sn100 kV/25 mAs (volume CT dose index, 0.2 mGy). CONCLUSIONS High image quality at very low dose levels can be achieved by using a Sn100-kV protocol with iterative reconstruction. The effective dose is comparable with that of conventional radiography, and the high image quality at even lower radiation exposure favors multidetector row CT over conebeam CT.
Collapse
|
26
|
Abstract
The potential risks of radiation exposure associated with computed tomography (CT) imaging are reason for ongoing concern for both medical staff and patients. Radiation dose reduction is, according to the as low as reasonably achievable principle, an important issue in clinical routine, research and development. The complex interaction of preparation, examination and post-processing provides a high potential for optimization on the one hand but on the other a high risk for errors. The radiologist is responsible for the quality of the CT examination which requires specialized and up-to-date knowledge. Most of the techniques for radiation dose reduction are independent of the system and manufacturer. The basic principle should be radiation dose optimization without loss of diagnostic image quality rather than just reduction.
Collapse
|
27
|
Mammografische Dichte als Risikofaktor für die Entstehung eines Mammakarzinoms – Ergebnisse einer deutschen Fall-Kontroll-Studie. Geburtshilfe Frauenheilkd 2011. [DOI: 10.1055/s-0031-1278623] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|
28
|
New drug development during and after a period of regulatory change: clinical research activity of major United States pharmaceutical firms, 1958 to 1979. Clin Pharmacol Ther 1983; 33:691-700. [PMID: 6851401 DOI: 10.1038/clpt.1983.95] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
The 1962 drug amendments fundamentally changed the way in which U.S. pharmaceutical firms could test new drugs in man and receive New Drug Application (NDA) approval. Although it is well known that the amendments and associated events caused a profound decline in the annual number of new drugs receiving NDA approval, the amendments' effects on clinical research into new chemical entities (NCEs) have not been investigated because data were unavailable. To study this we requested drug development information dating back to 1958 from most major United States-owned pharmaceutical firms and obtained complete responses from nine. The results showed that the introduction rate of NCEs into human testing dropped sharply in the early 1960s and declined substantially thereafter. The number of NCEs entering human testing fell from a mean of 89 a year in 1958-1962, to 35 a year in 1963-1972 (a reduction of 61%), and to 17 a year in the last 5 years of the survey, 1975-1979--an overall reduction of 81%. The number of NDA approvals received by these firms fell sharply by 49% in the early 1960s and more slowly for 10 years thereafter, from the mid-1960s to the mid-1970s. In the case of self-originated NCEs, the size of this later fall was 71%. Causes of these changes in NCE flow include the amendments and the events that prompted them; changes in scientific philosophy, standards, and state of the art; and economic factors.
Collapse
|
29
|
New drug development by United States pharmaceutical firms with analyses of trends in the acquisition and origin of drug candidates, 1963-1979. Clin Pharmacol Ther 1982; 32:407-17. [PMID: 7116754 DOI: 10.1038/clpt.1982.181] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
The average number of self-originated new chemical entities (NCEs) first tested in man by 39 United States-owned pharmaceutical firms in the 3-year period from 1977 to 1979 was 26 a year, approximately half the number investigated annually in the previous decade. Investigational New Drug (IND) Exemption filings on self-originated NCEs, but not those on acquired NCEs, were also comparatively low. Consequently, the contribution of self-originated NCEs to total IND filings fell from 81% in 1963 through 1975 to 68% in 1976 through 1979. (There was a similar decline, from 78% to 61%, in the proportion of compounds synthesized in the United States.) The relative increase in IND filings on acquired NCEs was greatest for smaller firms. By the late 1970s acquired NCEs accounted for almost 50% of the INDs filed by smaller firms, but only 10% to 25% of those filed by large and medium-sized firms. The importance of NCEs acquired from abroad has increased since the mid-1970s. The number of INDs filed on Japanese-originated NCEs rose from approximately one a year in 1963 through 1975 to an average of 3.5 a year in 1976 through 1979. Initial clinical testing of self-originated drugs abroad, which increased sharply in the early 1970s to reach a peak of 36% in 1976, declined to approximately 21% in 1977 through 1979. Self-originated drugs approved in 1977-1979 spent an average of 6 years in United States clinical testing and 2 in regulatory review, a total of 8 years from IND filing to NDA approval. The percentage of IND filings on self-originated NCEs that received New Drug Application (NDA) approval after 8 years or more was 9% overall, although ultimate success rates will be higher. There was a higher success rate for anti-infective drugs (17%) than for other pharmacologic categories (7%). For acquired NCEs, the overall approval rate was much larger (28%).
Collapse
|
30
|
In vivo methylation by Escherichia coli K-12 mec+ deoxyribonucleic acid-cytosine methylase protects against in vitro cleavage by the RII restriction endonuclease (R. Eco RII). J Bacteriol 1976; 126:990-6. [PMID: 770462 PMCID: PMC233238 DOI: 10.1128/jb.126.2.990-996.1976] [Citation(s) in RCA: 60] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
We have analyzed the susceptibility of the deoxyribonucleic acid (DNA) of phage fd replicative form (RF) and of Escherichia coli to in vitro cleavage by purified RII restriction endonuclease (R. Eco RII). The results are summarized as follows: (i) fd, mec- RFI, isolated from infected E. coli K-12 mec- bacteria (a mutant strain lacking DNA-cytosine methylase activity), is cleaved into at least two fragments, whereas fd. mec+ RFI, isolated from the parental mec+ strain, is not cleaved. (ii) E. coli mec- DNA is extensively degraded, whereas mec+ DNA-cytosine methylase acts as an RII modification enzyme.
Collapse
|
31
|
Analysis of bacteriophage deoxyribonucleic acid sequences methylated by host- and R-factor-controlled enzymes. J Bacteriol 1975; 123:768-70. [PMID: 1097428 PMCID: PMC235790 DOI: 10.1128/jb.123.2.768-770.1975] [Citation(s) in RCA: 59] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Phages lambda and fd were propagated in Escherichia coli strains that have either host K-12 or the N-3 R-factor deoxyribonucleic acid-cytosine methylase activity. Pyrimidine tracts containing 3H-labeled 5-methylcytosine (MeC) were analyzed; in all cases, the major methylated sequence was 5' ... C-MeC-T ... 3'.
Collapse
|
32
|
Abstract
Deoxyribonucleic acid (DNA)-cytosine methylation specified by the wild-type Escherichia coli K 12 mec+ gene and by the N-3 drug resistance (R) factor was studied in vivo and in vitro. Phage lambda and fd were propagated in the presence of L-[methyl-3H]methionine in various host bacteria. The in vivo labeled DNA was isolated from purified phage and depurinated by formic acid-diphenylamine treatment. The resulting pyrimidine oligonucleotide tracts were separated according to size and base composition by chromatography on diethylaminoethyl-cellulose in 7 M urea at pH 5.5 and 3.5, respectively. The distribution of labeled 5-methylcytosine in DNA pyrimidine tracts was identical for phage grown in mec+ and mec minus (N-3) cells. For phage lambda the major 5-methylcytosine containing tract was the tripyrimidine, C2T; for both fd-mec minus (N-3) DNA and fd-mec+DNA, C2T was the sole 5-methylcytosine-containing tract. When various lambda DNAs were methylated to saturation in vitro by crude extracts from mec+ and mec minus (N-3) cells, the extent of cytosine methylation was the same. This is in contrast to in vivo methylation where lambda-mec minus (N-3) DNA contains twice as many 5-methylcytosines per genome as lambda-mec+ DNA. Therefore, we suggest that the K12 met+ cytosine methylase and the N-3 plasmid modification methylase are capable of recognizing the same nucleotide sequences, but that the in vivo methylation rate is lower in mec+ cells.
Collapse
|
33
|
|
34
|
|