1
|
Sulfadiazine analogs: anti-Toxoplasma in vitro study of sulfonamide triazoles. Parasitol Res 2023; 122:2353-2365. [PMID: 37610452 PMCID: PMC10495491 DOI: 10.1007/s00436-023-07936-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2023] [Accepted: 08/03/2023] [Indexed: 08/24/2023]
Abstract
Toxoplasmosis is an infection that prevails all over the world and is caused by the obligate intracellular protozoan parasite Toxoplasma gondii (T. gondii). Promising novel compounds for the treatment of T. gondii are introduced in the current investigation. In order to test their in vitro potency against T. gondii tachyzoites, six 1,2,3-triazoles-based sulfonamide scaffolds with terminal NH2 or OH group were prepared and investigated as sulfadiazine equivalents. When compared to sulfadiazine, which served as a positive control, hybrid molecules showed much more anti-Toxoplasma activity. The results showed that the IC50 of the examined compounds 3(a-f) were recoded as 0.07492 μM, 0.07455 μM, 0.0392 μM, 0.03124 μM, 0.0533 μM, and 0.01835 μM, respectively, while the sulfadiazine exhibited 0.1852 μM. The studied 1,2,3-triazole-sulfadrug molecular conjugates 3(a-f) revealed selectivity index of 10.4, 8.9, 25.4, 21, 8.3, and 29; respectively. The current study focused on the newly synthesized amino derivatives 3(d-f), as they contain the more potent amino groups which are recognized to be essential elements and promote better biological activity. Extracellular tachyzoites underwent striking morphological alterations after 2 h of treatment as seen by scanning electron microscopy (SEM). Additionally, the intracellular tachyzoite exposed to the newly synthesized amino derivatives 3(d-f) for a 24-h period of treatment revealed damaged and altered morphology by transmission electron microscopic (TEM) indicating cytopathic effects. Moreover, compound 3f underwent the most pronounced changes, indicating that it had the strongest activity against T. gondii.
Collapse
|
2
|
Nanoformulation-Based 1,2,3-Triazole Sulfonamides for Anti- Toxoplasma In Vitro Study. Trop Med Infect Dis 2023; 8:401. [PMID: 37624339 PMCID: PMC10460005 DOI: 10.3390/tropicalmed8080401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 03/10/2023] [Accepted: 03/11/2023] [Indexed: 08/26/2023] Open
Abstract
Toxoplasma gondii is deemed a successful parasite worldwide with a wide range of hosts. Currently, a combination of pyrimethamine and sulfadiazine serves as the first-line treatment; however, these drugs have serious adverse effects. Therefore, it is imperative to focus on new therapies that produce the desired effect with the lowest possible dose. The designation and synthesis of sulfonamide-1,2,3-triazole hybrids (3a-c) were performed to create hybrid frameworks. The newly synthesized compounds were loaded on chitosan nanoparticles (CNPs) to form nanoformulations (3a.CNP, 3b.CNP, 3c.CNP) for further in vitro investigation as an anti-Toxoplasma treatment. The current study demonstrated that all examined compounds were active against T. gondii in vitro relative to the control drug, sulfadiazine. 3c.CNP showed the best impact against T. gondii with the lowest IC50 value of 3.64 µg/mL. Using light microscopy, it was found that Vero cells treated with the three nanoformulae showed remarkable morphological improvement, and tachyzoites were rarely seen in the treated cells. Moreover, scanning and transmission electron microscopic studies confirmed the efficacy of the prepared nanoformulae on the parasites. All of them caused parasite ultrastructural damage and altered morphology, suggesting a cytopathic effect and hence confirming their promising anti-Toxoplasma activity.
Collapse
|
3
|
Three techniques for the determination of perindopril through derivatization with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole. BMC Chem 2023; 17:64. [PMID: 37349827 DOI: 10.1186/s13065-023-00964-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2023] [Accepted: 05/25/2023] [Indexed: 06/24/2023] Open
Abstract
In addition to its pure form, three accurate, rapid, and simple methods have been established for determining perindopril (PRD) in its tablet form. At pH 9.0 using a borate buffer, developing the three designated methods was successful according to the reaction between PRD and 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole (NBD-Cl) and the formation of a chromogen (with a yellow color) measurable at 460 nm using the spectrophotometric method (Method I). In addition, the produced chromogen was assessed using the spectrofluorimetric method (Method II) at 535 nm following excitation at 461 nm. Afterward, the same reaction product was separated and determined using the HPLC method with fluorescence detection (Method III). A Promosil C18 stainless steel column (Q7 5 mm particle size, 250-4.6 mm) has proven suitable for separation. The mobile phase adjustment was made at pH 3.0, with a 1.0 mL min -1 flow rate; its composition was methanol-sodium dihydrogen phosphate, 0.02 M (60: 40, v/v). Through concentration ranges of 5.0-60.0, 0.5-6.0, and 1.0-10.0 μg mL-1, the calibration curves were rectilinear for Methods I, II, and III, respectively, with limits of quantification (LOQ) of 1.08, 0.16 and 0.19 μg mL-1 as well as limits of detection (LOD) of 0.36, 0.05 and 0.06 μg mL-1. The developed methods were implemented to estimate PRD in tablets, and a comparison between the obtained outcomes utilizing the developed methods as well as obtained from the official method revealed that they were comparable. The official BP method was based on dissolving PRD in anhydrous acetic acid and titrating with 0.1 M perchloric acid, then the potentiometric determination of the end-point. The designated methods were also implemented in content uniformity testing with satisfying results. The reaction pathway proposal was speculated, and according to ICH Guidelines, the statistical evaluation of the data was performed. The three proposed methods were confirmed to be green, eco-friendly and safe to environment using Green Analytical procedure index (GAPI) method.
Collapse
|
4
|
Epidemiological profile of microbial keratitis in Alexandria-Egypt a 5 years retrospective study. J Ophthalmic Inflamm Infect 2023; 13:18. [PMID: 37055636 PMCID: PMC10102273 DOI: 10.1186/s12348-023-00332-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Accepted: 02/26/2023] [Indexed: 04/15/2023] Open
Abstract
OBJECTIVE To evaluate the epidemiologic profile of microbial keratitis in Alexandria- Egypt, with special emphasis on risk factors, visual outcome and microbiological results. METHODS This retrospective study reviewed files of patients treated for microbial keratitis during a period of 5 years at Alexandria Ophthalmology Hospital Cornea Clinic, Alexandria- Egypt, between February 2017 and June 2022. The patients were evaluated for the risk factors e.g., trauma, eyelid disorders, co-morbidities, and contact lens use. They were also evaluated for their clinical picture, the identified microorganisms, visual outcomes, and complications. Non-microbial keratitis and incomplete files were excluded from the study. RESULTS A total of 284 patients were diagnosed as microbial keratitis in our study. Viral keratitis was the most common cause of microbial keratitis (n = 118 (41.55%)), followed by bacterial keratitis (n = 77 (27.11%)), mixed keratitis (n = 51 (17.96%)), acanthamoeba keratitis (n = 22 (7.75%)) and the least cause was fungal keratitis (n = 16 (5.63%)). Trauma was the most common risk factor for microbial keratitis (29.2%). Fungal keratitis had a statistically significant association with trauma (p < 0.001), while the use of contact lenses had a statistically significant association with Acanthamoeba keratitis (p < 0.001). The percentage of culture-positive results in our study was 76.8%. Gram-positive bacteria were the most frequently isolated bacterial isolate (n = 25 (36.2%)), while filamentous fungi were the most frequently isolated fungi (n = 13(18.8%)). After treatment, there was a significant increase in the mean visual acuity among all groups; it was significantly higher in Acanthamoeba keratitis group with a mean difference of 0.262 ± 0.161 (p = 0.003). CONCLUSION Viral keratitis followed by bacterial keratitis were the most frequent etiologic agents causing microbial keratitis found in our study. Although trauma was the most frequent risk factor for microbial keratitis, contact lens wear was found an important preventable risk factor for microbial keratitis in young patients. Performing culture properly whenever indicated before starting antimicrobial treatment increased the cultures' positive results.
Collapse
|
5
|
Proposed morbidity markers among Schistosoma mansoni patients. Trop Parasitol 2023; 13:40-45. [PMID: 37415754 PMCID: PMC10321587 DOI: 10.4103/tp.tp_46_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2022] [Revised: 01/18/2023] [Accepted: 02/02/2023] [Indexed: 07/08/2023] Open
Abstract
Background Fecal calprotectin (FC) and fecal occult blood (FOB) were suggested as potential inflammatory markers for assessing intestinal schistosomiasis morbidity that are conventionally detected through invasive methods. Aim and Objectives The present work aimed to evaluate FC and FOB as morbidity markers of Schistosoma mansoni infection before and after praziquantel treatment. Materials and Methods A total of 205 stool samples (117 schoolchildren and 88 adults) were collected and examined by Kato Katz. A questionnaire enquiring about diarrhea, history of blood in stool, and abdominal pain was designed and applied. Results S. mansoni prevalence rates were 20.5% and 11.36% among children and adults, respectively; the majority of cases had light infection intensity. FC and FOB were studied among 25 cured S. mansoni cases (17 children and 8 adults) pre and one-month post treatment. Before treatment, six and four children of moderate and high S. mansoni infection intensity tested positive for FC and FOB, respectively, all turning negative after treatment. FC showed borderline statistical significance before and after treatment among children. However, all adults tested negative for FC and FOB. Conclusion FC and FOB could be possibly used as morbidity monitoring tools for S. mansoni infection in children with moderate and high infection intensity.
Collapse
|
6
|
Molecular diagnosis and subtyping of Blastocystis sp.: Association with clinical, colonoscopic, and histopathological findings. Trop Parasitol 2023; 13:46-53. [PMID: 37415748 PMCID: PMC10321588 DOI: 10.4103/tp.tp_28_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Revised: 07/11/2022] [Accepted: 02/02/2023] [Indexed: 07/08/2023] Open
Abstract
Introduction Blastocystis sp. is the most common parasitic infestation in humans. However, its pathogenicity remains controversial. Our aim was to study the prevalence of Blastocystis sp. parasite subtypes in patients with gastrointestinal manifestations referred for colonoscopy and assess possible correlation with clinical, colonoscopic, and histopathological findings. Methodology One hundred patients with gastrointestinal manifestations referred for colonoscopy were enrolled. Stool samples were collected and examined both microscopically and by real-time quantitative polymerase chain reaction (qPCR) for detection of Blastocystis sp. Subtyping was done for positive samples by qPCR and confirmed by sequencing. Results qPCR sensitivity far exceeded microscopy in detection of Blastocystis sp. (58% vs. 31%, agreement 38.5%). The most commonly detected subtype was 3 (50%), followed by 2 (32.8%) and 4 (13.8%). Abdominal pain was the most common clinical symptom; inflammation and colitis were the most common abnormal colonoscopic and histopathological findings. The most frequent subtype encountered in those findings was Subtype 3. Conclusions This study confirmed the importance of using qPCR in diagnosis of Blastocystis sp. An association between abnormal clinical, colonoscopic, and histopathological findings on the one hand, and Blastocystis sp. infestation, especially Subtype 3, on the other hand, is also posed. This necessitates further studies to assess the mechanism of association with pathogenicity.
Collapse
|
7
|
Evaluation of microscopy and PCR for detection of Dientamoeba fragilis. Trop Parasitol 2022; 12:87-93. [PMID: 36643979 PMCID: PMC9832490 DOI: 10.4103/tp.tp_93_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Revised: 02/09/2022] [Accepted: 03/03/2022] [Indexed: 11/25/2022] Open
Abstract
Introduction Dientamoeba fragilis (D. fragilis) diagnosis is an intestinal protozoan parasite globally found in rural and urban areas and is attracting a growing interest. Its prevalence in stool varies from 0.2% to more than 19% depending upon the population studied. Materials and Methods This study was based on the examination of 100 stool samples of randomly referred cases in a rural area in Motobus district, Kafr El-Sheikh governorate, Egypt. Our aim was to investigate the presence of D. fragilis in stool of the examined individuals using conventional polymerase chain reaction (PCR) compared to wet mount and trichrome stain with confirmation of infection by transmission electron microscopy. Results D. fragilis was detected in 13/100 of the stool samples examined using wet mount smears, while trichrome stain detected 17/100. Conventional PCR diagnosed 41 cases of D. fragilis in the studied group. A very good agreement was found between wet mount and trichrome stain for diagnosing D. fragilis, while there was fair agreement between conventional PCR and both microscopy methods. Transmission electron microscope was performed on pooled positive samples that revealed the internal structures of D. fragilis trophozoite with its characteristic nucleus. Conclusions PCR technique was superior to microscopy for the detection of D. fragilis. Trichrome stain remains vital for microscopic diagnosis.
Collapse
|
8
|
Concurrent estimation of some co-administered antimicrobial drugs applying conventional and first derivative synchronous fluorescence spectroscopy techniques. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2022; 264:120255. [PMID: 34464919 DOI: 10.1016/j.saa.2021.120255] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Revised: 07/31/2021] [Accepted: 08/02/2021] [Indexed: 06/13/2023]
Abstract
For the estimation of some co-administered antimicrobials, two highly accurate and precise spectrofluorimetric methods were developed. Fluconazole (FLZ) is co-administered with either ciprofloxacin (CPR) or ofloxacin (OFX) for the treatment of certain microbial infections. On the other hand, another antimicrobial drug, vancomycin (VNC) is co-administered with ciprofloxacin (CPR) for peritonitis treatment. In method I, conventional spectrofluorimetry has been introduced for the concurrent quantitative estimation of FLZ in presence of OFX or CPR. While in method II, a first derivative synchronous spectrofluorimetric technique was adapted for quantitation of VNC and CPR co-administered combination. Both of them were utilized for estimation of the considered drugs in raw materials, laboratory prepared mixtures, dosage forms, and biological fluids. Method I was relied on simultaneous measuring of the native fluorescence of FLZ and OFX or CPR without any overlapping between the emission spectra of each binary mixture (FLZ / OFX) and (FLZ / CPR). Fluorescence intensities were measured at 283.0, 483.0 and 436.0 nm after excitation at 262.0, 292.0 and 275.0 nm for FLZ, OFX and CPR, respectively. Method II was utilized the synchronous fluorescence intensity of VNC and CPR in methanol at Δλ = 40 nm. The first derivative synchronous spectra were calibrated at 297.0 nm for VNC and at 379.5 nm for CPR. Different variables influencing conventional and synchronous fluorescence intensities of the four antimicrobials under investigation were precisely optimized. Both methods were successfully investigated for the determination of the studied drugs in plasma. The linear data analysis for the calibration curves reveals a good relationship in the ranges of 1.0-10.0, 0.25-2.5 and 0.06-0.6 μg/mL for FLZ, OFX and CPR for method I with limits of detection 0.144, 0.038 and 0.007 μg/mL and limits of quantitation of 0.437, 0.114 and 0.021 μg/mL for FLZ, OFX and CPR, respectively. Linearity range for method II was 0.5 -10.0 μg/mL for VNC and CPR with detection limits of 0.127 and 0.110 μg/mL and quantitation limits of 0.380 and 0.334 μg/mL for VNC and CPR, respectively. International Council on Harmonization ICH Q2 (R1) Guidelines were followed in the developed methods validation. The achieved outcomes were statistically compared with those found by the reported ones, and no significant difference was observed.
Collapse
|
9
|
Insights for applying erythrosine B as a green fluorescence probe for estimation of anticancer tamoxifen and its analog; clomiphene in nanogram concentration. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2021; 263:120156. [PMID: 34293668 DOI: 10.1016/j.saa.2021.120156] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2021] [Revised: 06/20/2021] [Accepted: 07/02/2021] [Indexed: 06/13/2023]
Abstract
The growth of tumor tissue is extremely pervasive among post-menopausal women. Commonly, from the clinical application, adjuvant selective estrogen receptor modulators such as tamoxifen are prescribed for prohibiting metastatic breast cancer, while its analog, clomiphene, is used to treat infertility in women. Lately, the significance of green chemistry on our environment was through reducing the influence of hazardous chemicals. Consequently, efforts were screened to perform a fast and simple eco-friendly green method for the determination of two aromatase inhibitors. In this study, a sensitive green spectrofluorimetric approach was developed to detect and characterize tamoxifen citrate (TAM) and clomiphene citrate (CLO) via complex formation with erythrosine B. The reaction between erythrosine B dye (EB) and the two aromatase inhibitors results in quenching the fluorescence activity of the dye by the formation of ion-pair in Britton-Robinson buffer (BRB) solution (pH 4.3) at 554 nm (λex = 527 nm). The approach outcome confirmed that the solvent's inherent nature has a critical impact on the approachs' sensitivity and reproducibility. An approved linear correlation was achieved between the reduction in the emission value of EB's fluorescence and the concentration in the ranges of 40.0-600.0 ng/mL for both TAM and CLO with mean % recoveries 100.20 ± 0.93 and 100.07 ± 1.09, respectively. The approach was validated regarding ICH protocols, and the outcomes were acceptable. The changes in Gibb's free energy (ΔG°) by the obtained ion-pair between EB and TAM or CLO were -36.65 or -37.03 kJ mol-1, respectively, which indicates the reaction feasibility at ambient temperature. Commercial dosage forms for TAM and CLO were simply analyzed, and good recoveries were achieved within the range. The National Environmental Methods Index, Analytical Eco-Scale, and Green Analytical Procedure Index applications to our illustrated approach present additional eligibility to this study.
Collapse
|
10
|
Detection and Molecular Identification of Cryptosporidium Species Among Children with Malignancies. Acta Parasitol 2021; 66:377-383. [PMID: 33025352 DOI: 10.1007/s11686-020-00250-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Accepted: 06/25/2020] [Indexed: 10/22/2022]
Abstract
BACKGROUND Cryptosporidiosis represents a major health problem worldwide particularly among children. Its diagnosis is still difficult and demands sensitive methods. In Egypt, there is little documentation of infection among children with malignancies. This work was designed to study the infection rate of Cryptosporidium among children with malignancies, compare the performance of modified Ziehl-Neelsen (MZN) stain with nested polymerase chain reaction (PCR) and identify the species subtypes of positive cases. METHODS The study was conducted on 100 children with malignancies (leukemia, lymphoma and solid tumors), below 10 years of age, from El-Shatby hospital, Alexandria University. After obtaining the informed consent, their stool samples were collected and examined microscopically following MZN stain for the diagnosis of Cryptosporidium spp. All samples were then subjected to nested PCR. Restriction fragment length polymorphism (RFLP) targeting the Cryptosporidium oocyst wall protein (COWP) gene was applied to positive cases, using restriction enzyme RsaI for digestion of nested PCR products. RESULTS Out of the 100 examined children, MZN detected higher positive cases compared to nested PCR. Six cases (6%) were diagnosed positive by MZN stain, three of which (3%) were concordantly positive by nested PCR. All positives were among children with acute lymphoblastic leukemia (ALL). Fair agreement was found between the two tests (K = 0.36). Genotyping results revealed that positive samples were of Cryptosporidium parvum (C. parvum) type II. CONCLUSIONS Low Cryptosporidium infection rate was detected among children with malignancies. MZN diagnosed more positive cases compared to nested PCR. C. parvum type II was the identified species among the examined children. Further optimization of PCR steps is needed.
Collapse
|
11
|
Intestinal Microsporidia Infection in Leukemic Children: Microscopic and Molecular Detection. Acta Parasitol 2021; 66:346-353. [PMID: 32996015 DOI: 10.1007/s11686-020-00283-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Accepted: 09/15/2020] [Indexed: 12/16/2022]
Abstract
BACKGROUND Microsporidia infection was originally described as an immunocompromised associated pathogen. Limitations to correct microscopic diagnosis of microsporidia include size of the organism presenting a challenge even to a highly competent laboratory expert. OBJECTIVE The present study aimed to detect microsporidia infection among leukemic children. The performance of modified trichrome stain and PCR in the diagnosis of microsporidia was evaluated with further speciation. METHODS Stool samples of 100 leukemic children on chemotherapy were examined microscopically for microsporidia. DNA was extracted from all samples. Amplification was performed by conventional and nested PCR. Sequencing of amplified products was performed on unspeciated samples. RESULTS Microsporidia were detected in 23% of the children by MTS and 29% by PCR. The 29 positive samples were subjected to PCR for speciation. Enterocytozoon bieneusi was found to predominate in 20 cases, Encephalitozoon intestinalis in three cases, two cases had co-infection, and the remaining four samples were not amplified with either E. bieneusi or E. intestinalis specific primers. By DNA sequencing of the unspeciated samples, three samples shared high homology with Encephalitozoon hellem and one sample with Encephalitozoon cuniculi. Referring to PCR as a gold standard, MTS exhibited 72.4% sensitivity and 97.2% specificity with 90% accuracy. Among a number of studied variables, diarrhea and colic were significantly associated with microsporidia infection when diagnosed by either technique. CONCLUSION The use of sensitive and discriminative molecular tools will contribute to determining the true prevalence of microsporidiosis and possibly their potential transmission source depending on species identification.
Collapse
|
12
|
Investigation of some univariate and multivariate spectrophotometric methods for concurrent estimation of Vancomycin and Ciprofloxacin in their laboratory prepared mixture and application to biological fluids. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2021; 253:119570. [PMID: 33621934 DOI: 10.1016/j.saa.2021.119570] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2020] [Revised: 01/26/2021] [Accepted: 01/28/2021] [Indexed: 06/12/2023]
Abstract
Four simple, rapid, accurate and precise spectrophotometric methods were established and validated in accordance with ICH Q2 (R1) guidelines for the simultaneous determination of Vancomycin (VNC) and Ciprofloxacin (CPR) in their raw materials, laboratory prepared mixtures and pharmaceutics. Method A depends on using first derivative spectrophotometry (D1) where VNC and CPR were resolved at 243.6 and 262.0 nm, respectively. Concerning method B, it is based on utilizing first derivative of ratio spectra (DD1) where determination was performed at the peak maxima at 244.0 nm and 258.0 nm for VNC and CPR, respectively. Two chemometric models were applied for the quantitative analysis of both drugs in their laboratory prepared mixtures, namely, partial least squares (PLS) (method C) and artificial neural network (ANN) (method D). For univariate methods linearity range for both drugs was in the range of 3-30 and 1-10 μg/mL for VNC and CPR, respectively. Multivariate calibration methods using five level, two factor calibration model for the development of 25 mixtures were also applied for the simultaneous estimation of the two drugs in their laboratory prepared mixture using spectral region from 200.0 to 300.0 nm using interval 1 nm. The suggested methods have been successfully extended to the assay of the two studied drugs in laboratory-prepared mixtures and pharmaceuticals with excellent recovery. First derivative spectrophotometry (D1) was also applied for the assay of both analytes in spiked human plasma with good recovery. No interaction with common pharmaceutical additives has been observed which indicate the selectivity of the method. The results obtained were favourably compared with those obtained applying the reported methods. The methods are validated in compliance with the ICH Q2 (R1) guidelines and the measured accuracy and precision are assessed to be within the accepted limits.
Collapse
|
13
|
Intestinal schistosomiasis: Can a urine sample decide the infection? Parasitol Int 2020; 80:102201. [PMID: 33010472 DOI: 10.1016/j.parint.2020.102201] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2020] [Revised: 06/19/2020] [Accepted: 09/01/2020] [Indexed: 12/17/2022]
Abstract
Intestinal schistosomiasis, one of the neglected tropical diseases whose control depends on accurate diagnosis of the disease prevalence. The use of low sensitive Kato Katz (KK) fecal egg detection method as a reference gold standard is not an accurate indication especially in low transmission areas. Latent class analysis frameworks especially the Bayesian could be used instead to compare between different diagnostic tests without the use of a gold standard method as a reference. Thus, this study compared two urine-based tests for the detection of circulating antigen and cell free DNA of Schistosoma mansoni versus KK method using the Bayesian latent class analytical framework and in two models where the trace results of point of contact - assay of circulating cathodic antigen (POC-CCA) were once estimated as positive, and as negative in the other model. The Bayesian framework in the trace CCA positive model showed an estimate of disease prevalence of 26% (95% BCI:0 to 60%). POC-CCA showed the highest sensitivity (74% with BCI: 9 to 91%) and lowest specificity for (20% with BCI: 0% to 37%) and the reverse for KK. For POC-CCA with traces considered negative, it was found that results between the three tests were moderated where the positivity for infection by Schistosoma antigen detection and PCR for cell free DNA approached that estimated by the Bayesian framework (44%), and the specificity for point of contact assay(81%; 95%BCI: 59% to 100%) rose in hand with its sensitivity(77%, 95% BCI:53% to 100%) and with results for PCR test (sensitivity = 80%; 95% BCI: 61% to 100%, specificity = 69%; 95% BIC: 47% to 100%). KK remains with the highest specificity while its sensitivity in the two models never exceeded 22%. Thus, we conclude that the use of a single urine sample could be very sensitive and highly specific in the diagnosis of intestinal schistosomiasis using either the trace negative model of point of contact assay, or conventional PCR, when compared to the fecal egg detection using duplicate KK. However, the use of a single tool restricts the management of the disease in areas of low endemicity.
Collapse
|
14
|
Eristalis tenax intestinal myiasis: An electron microscope study. Trop Parasitol 2020; 10:39-43. [PMID: 32775291 PMCID: PMC7365507 DOI: 10.4103/tp.tp_40_19] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2019] [Accepted: 02/02/2020] [Indexed: 11/23/2022] Open
Abstract
Myiasis is the infestation of live vertebrates (humans or animals) with dipterous larvae. Eristalis tenax, belonging to order Diptera and family Syrphidae, seldom causes accidental myiasis, usually due to ingestion of contaminated food or water by humans. Here, we report a case of intestinal myiasis in a male from Alexandria, Egypt, complaining of frequent passage of small worms in his stool. A larva and a pupa were presented to the laboratory and examined macroscopically, and then studied by a scanning electron microscope. E. tenax (rat-tailed maggots) were diagnosed. Rarely diagnosed worldwide, a case of E. tenax accidental intestinal myiasis was found in a middle-aged adult male from Egypt. A larva and a pupa were identified and studied macroscopically and by scanning electron microscope.
Collapse
|
15
|
Improving Hashimoto's thyroiditis by eradicating Blastocystis hominis: Relation to IL-17. Ther Adv Endocrinol Metab 2020; 11:2042018820907013. [PMID: 32128107 PMCID: PMC7036484 DOI: 10.1177/2042018820907013] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2019] [Accepted: 01/27/2020] [Indexed: 12/11/2022] Open
Abstract
BACKGROUND Hashimoto's thyroiditis (HT) is a common autoimmune disorder that causes significant morbidity. Interleukin (IL)-17 was identified as a major contributing factor in the pathogenesis of HT. Blastocystis hominis (BH) is a very common infection and has been shown to be associated with several diseases. Our aim was to determine serum IL-17 level in HT patients with and without BH infection and the effect of eradicating BH in patients with HT. METHODS A prospective cohort study was conducted on 20 HT patients not infected with BH (group I), 20 HT patients infected with BH (group II), and 20 healthy patients (group III). Serum free triiodothyronine (FT3), free thyroxine (FT4), thyroid stimulating hormone (TSH), thyroid peroxidase antibodies (anti-TPO), and IL-17 were performed by ELISA method and were repeated in group II after 6 weeks of eradication of BH. RESULTS Patients with HT showed a significantly higher serum IL-17 compared with controls. IL-17 was significantly higher in HT patients infected with BH compared with HT patients not BH infected (mean 6.93 ± 2.83 pg/ml versus 3.25 ± 1.55 pg/ml, p = 0.003). After BH eradication TSH, anti-TPO, and IL-17 were significantly decreased (mean 14.76 ± 11.11 µIU/ml versus 9.39 ± 7.11 µIU/ml, p < 0.001; mean 308 ± 175.6 IU/ml versus 295.4 ± 167.1 IU/ml, p = 0.006; and mean 6.93 ± 2.83 pg/ml versus 6.45 ± 2.48 pg/ml, p < 0.001), respectively. Multivariate analysis after treating BH infection showed that IL-17 was significantly negatively correlated with FT3 (adjusted p = 0.002) and significantly positively correlated with anti-TPO (adjusted p = 0.045). CONCLUSION Treatment of BH infection ameliorates HT through reduction in IL-17, anti-TPO, and TSH. CLINICAL TRIAL REGISTRATION NUMBER PACTR201909495111649.
Collapse
|
16
|
Urinary circulating DNA and circulating antigen for diagnosis of schistosomiasis mansoni: a field study. Trop Med Int Health 2019; 24:371-378. [PMID: 30549391 DOI: 10.1111/tmi.13193] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
OBJECTIVE To evaluate three non-invasive assays for the diagnosis of schistosomiasis mansoni in an Egyptian village. METHODS Urine was collected for the detection of circulating cathodic antigen (CCA) and cell-free parasite DNA (cfpd) by Point-of-contact (POC)-cassette assay and PCR, respectively. These tests were compared to Kato-Katz (KK) faecal thick smear for detection of Schistosoma mansoni eggs. RESULTS Disease prevalence by POC-CCA assay was 86%; by PCR it was 39% vs. 27% by KK. Compared to KK, the sensitivity of POC-CCA reached 100%, but its specificity was only 19.2% with 41% accuracy. Sensitivity of the PCR assay for cfpd was 55.56%, and specificity was 67.12% with 64% accuracy. A new end point was calculated for combined analysis of KK, POC-CCA assay and PCR. Sensitivity for the three tests was 52.94%, 90.2% and 76.47%; specificity was 100% for KK and PCR and 18.37% for POC-CCA. The accuracy calculated for the three tests at the end point was 76% for KK, 55% for POC-CCA assay and 88% for PCR. CONCLUSION Conventional PCR assay for detection of cfpd provides a potential screening tool for intestinal schistosomiasis with reliable specificity, reasonable accuracy and affordable financial and technical cost.
Collapse
|
17
|
Two liquid chromatographic approaches for the simultaneous determination of xipamide and its degradation product (2,6-xylidine) using time-programmed fluorescence detection. LUMINESCENCE 2016; 32:491-501. [PMID: 27562288 DOI: 10.1002/bio.3203] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2016] [Revised: 07/05/2016] [Accepted: 07/24/2016] [Indexed: 11/09/2022]
Abstract
A study of the performance of reversed-phase chromatography with a programmable multiwavelength fluorimetric technique using either conventional hydro-organic or micellar eluent is established for the determination of xipamide (XIP) in the presence of its degradation product, 2,6-xylidine (XY). In conventional liquid chromatography (CLC), the analyses were carried out on a Promosil ODS 100 Å column (250 mm × 4.6 mm i.d., 5 μm) using a mobile phase consisting of methanol/0.1 M phosphate buffer (65: 35, v/v) at pH 4.0. For micellar liquid chromatography (MLC), a short Spherisorb column (150 mm × 4.6 mm i.d., 5 μm) was employed in conjunction with a greener mobile phase (pH 5.0) containing 0.1 M sodium dodecyl sulfate and 15% n-propanol. CLC proved to be superior to MLC in terms of sensitivity for the determination of the degradation product because it could detect trace amounts down to 10.0 ng/ml of XY as a degradation product in XIP. However, MLC represents an eco-friendly approach for the simultaneous determination of XIP and XY. In addition, the opportunity for the direct introduction of biological matrices into the chromatographic system is one of the distinctive benefits of MLC. The proposed methods were applied for the determination of XIP in its tablets, human urine and content uniformity testing. The results of the proposed methods were statistically compared with those obtained using the comparison fluorimetric method, revealing no significant differences in the performance of the methods regarding accuracy and precision.
Collapse
|
18
|
Determination of adapalene in gel formulation by conventional and derivative synchronous fluorimetric approaches. Application to stability studies and in vitro diffusion test. Chem Cent J 2016; 10:33. [PMID: 27239224 PMCID: PMC4884421 DOI: 10.1186/s13065-016-0181-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2016] [Accepted: 05/17/2016] [Indexed: 11/17/2022] Open
Abstract
Background Adapalene is a retinoid analogue with actions similar to those of tretinoin. It is used in topical treatment of mild to moderate acne. A survey of the literature reveals that no spectrofluorimetric method has been reported yet for determination of ADP, so it was thought necessary to develop a highly sensitive stability indicating spectrofluorimetric method. Results Two highly sensitive spectrofluorimetric approaches were conducted for the assay of adapalene (ADP) in its gel. In the first approach, ADP exhibits an intense native fluorescence at 389 nm after excitation at 312 nm using borate buffer (pH 7.0)/ethanol system. This approach was successfully applied for routine analysis of ADP in its gel and ideally suited to the in vitro diffusion test. To elucidate the inherent stability of ADP, bulk sample was subjected to different stress conditions as specified by ICH guidelines. The acidic and oxidative degradation products were resolved from the intact drug using second and first derivative synchronous fluorimetry at 346 and 312.45 nm, respectively (the second approach). The synchronous fluorescence was scanned at Δ λ of 80 nm in case of acidic degradation and at Δ λ of 100 nm in case of oxidative degradation. Good linearity was obtained for ADP over the range 2.0–14.0 ng/mL with good correlation coefficient 0.999 in each approach. The approaches were carefully examined in terms of linearity, accuracy and precision. They were suitable for routine quality control laboratory. Moreover, the stability-indicating power of the second approach was ascertained via forced degradation studies. Conclusions The proposed approaches were validated and successfully applied for the quantitative assay of a small concentration of ADP in its pharmaceutical gel. The conventional spectrofluorimetry was ideally suited for in vitro diffusion test. Stability studies were also conducted using different forced degradation condition according to ICH recommendation.Simultaneous determination of ADP and its degradation products. ![]()
Collapse
|
19
|
Spectrofluorimetric determination of amisulpride and bumidazone in raw materials and tablets. LUMINESCENCE 2014; 29:1202-5. [PMID: 24723476 DOI: 10.1002/bio.2673] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2013] [Revised: 02/18/2014] [Accepted: 02/25/2014] [Indexed: 11/11/2022]
Abstract
A highly sensitive, simple and rapid spectrofluorimetric method was developed for the determination of amisulpride (AMS) and bumidazone (BUM) in tablet form. The proposed method is based on measuring the native fluorescence of the studied drugs in methanol at 360 and 344 nm after excitation at 276 and 232 nm for AMS and BUM, respectively. The fluorescence-concentration plots were rectilinear over the ranges of 5.0-60.0 ng/mL for AMS and 0.5-5.0 µg/mL for BUM. The lower detection limits were 0.70 ng/mL and 0.06 µg/mL, and the lower quantification limits were 2.0 ng/mL and 0.18 µg/mL for AMS and BUM, respectively. The method was successfully applied for the analysis of AMS and BUM in commercial tablets. Statistical evaluation and comparison of the data obtained using the proposed and comparison methods revealed good accuracy and precision for the proposed method.
Collapse
|
20
|
Genotype analysis of T. gondii strains associated with human infection in Egypt. Parasitol Res 2014; 113:1563-9. [DOI: 10.1007/s00436-014-3801-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2013] [Accepted: 01/28/2014] [Indexed: 11/29/2022]
|
21
|
Kinetic determination of acarbose and miglitol in bulk and pharmaceutical formulations using alkaline potassium permanganate. INTERNATIONAL JOURNAL OF BIOMEDICAL SCIENCE : IJBS 2007; 3:20-30. [PMID: 23675017 PMCID: PMC3614621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
A simple and sensitive kinetic spectrophotometric method was established for the determination of acarbose and miglitol in bulk and in their pharmaceutical preparations using alkaline potassium permanganate as an oxidizing agent. The method involves determination of acarbose and miglitol by kinetic studies of their oxidation at room temperature for a fixed time of 15 minutes for acarbose and 25 minutes for miglitol. The absorbance of the colored manganate ion was measured at 610 nm. Alternatively, the kinetic decrease in the absorbance of permanganate upon addition of the studied drugs at 525 nm was also used. The absorbance concentration plot was rectilinear over the concentration range of 4-20 and 1-10 μg/ml for acarbose and miglitol, respectively. The detection limits were 0.189 and 0.089 μg/ml at 610 nm and 0.081 and 0.179 μg/ml at 525 nm for acarbose and miglitol respectively. The method was successfully applied for the determination of these drugs in their dosage forms. The results obtained were in good agreement with those obtained with the reference methods.
Collapse
|