1
|
Awake tracheal intubation in routine airway management: A retrospective analysis in a tertiary centre. PLoS One 2024; 19:e0299071. [PMID: 38427680 PMCID: PMC10906896 DOI: 10.1371/journal.pone.0299071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Accepted: 02/03/2024] [Indexed: 03/03/2024] Open
Abstract
INTRODUCTION While awake tracheal intubation (ATI) is regarded as the gold standard for difficult airway management according to current guidelines, there seems to be a reluctance in its application. This retrospective cohort study, conducted at a German tertiary hospital over a 2-year period, aimed to demonstrate that integrating awake tracheal intubation using flexible bronchoscopy (ATI:FB) into routine airway management makes it a successful and safe approach. MATERIALS AND METHODS In 2019 and 2020, records from the data acquisition system (DAQ) and archived anesthesia records were screened to evaluate the specifics of ATI:FB procedures, focusing on overall success and safety. Analysis included complications, time required for ATI:FB, and potential influencing factors such as patient characteristics, indication, medical/operative specialty, sedation technique, route and experience of anesthesiologist. Logistic regression assessed the impact of various variables on occurrence of complications and linear regression, with log(time) as the dependent variable, evaluated median time required to perform ATI:FB. RESULTS ATI:FB constituted 4.3 % (n = 1,911) of all airway management procedures, predominantly observed in dental, oral, and maxillofacial surgery (46.5 %) and otorhinolaryngology (38.4 %). The success rate for ATI:FB was notably high at 99.6 %, with only 5.4 % of cases experiencing complications, including technical issues, agitation, and visibility obstruction due to mucous secretion. Complication risk was influenced by the medical specialty and the experience of the anesthesiologist. A strong effect was observed in otorhinolaryngology (OR = 4.54, 95 % CI [1.64; 14.06]). The median time required for ATI:FB was 16 minutes (IQR: 11 to 23), with factors such as indication (p < 0.0001), experience of anesthesiologist (p < 0.0001), sedation technique (p = 0.0408), priority of the procedure (p = 0.0134), and medical/operative specialty (p < 0.0001) affecting the duration. The median time required for ATI:FB differed significantly based on the experience of the anesthesiologist (p < 0.0001). CONCLUSION ATI:FB proves successful and safe, with low complications and manageable procedural time. Experience of the anesthesiologist is a modifiable factor enhancing safety, emphasizing the need for ATI:FB integration into routine airway management.
Collapse
|
2
|
Early warning for SpO 2 decrease by the oxygen reserve index in neonates and small infants. Paediatr Anaesth 2023; 33:923-929. [PMID: 37551627 DOI: 10.1111/pan.14743] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 07/20/2023] [Accepted: 07/24/2023] [Indexed: 08/09/2023]
Abstract
INTRODUCTION Continuously assessing the oxygenation levels of patients to detect and prevent hypoxemia can be advantageous for safe anesthesia, especially in neonates and small infants. The oxygen reserve index (ORI) is a new parameter that can assess oxygenation through a relationship with arterial oxygen partial pressure (PaO2 ). The aim of this study was to examine whether the ORI provides a clinically relevant warning time for an impending SpO2 (pulse oximetry hemoglobin saturation) reduction in neonates and small infants. METHODS ORI and SpO2 were measured continuously in infants aged <2 years during general anesthesia. The warning time and sensitivity of different ORI alarms for detecting impending SpO2 decrease were calculated. Subsequently, the agreement of the ORI and PaO2 with blood gas analyses was assessed. RESULTS The ORI of 100 small infants and neonates with a median age of 9 months (min-max, 0-21 months) and weight of 8.35 kg (min-max, 2-13 kg) were measured. For the ORI/PaO2 correlation, 54 blood gas analyses were performed. The warning time and sensitivity of the preset ORI alarm during the entire duration of anesthesia were 84 s (25th-75th percentile, 56-102 s) and 55% (95% CI 52%-58%), and those during anesthesia induction were 63 s (40-82 s) and 56% (44%-68%), respectively. The positive predictive value of the preset ORI alarm were 18% (95% CI 17%-20%; entire duration of anesthesia) and 27% (95% CI 21%-35%; during anesthesia induction). The agreement of PaO2 intervals with the ORI intervals was poor, with a kappa of 0.00 (95% CI = [-0.18; 0.18]). The weight (p = .0129) and height (p = .0376) of the infants and neonates were correlated to the correct classification of the PaO2 interval with the ORI interval. CONCLUSIONS The ORI provided an early warning time for detecting an impending SpO2 decrease in small infants and neonates in the defined interval in this study. However, the sensitivity of ORI to forewarn a SpO2 decrease and the agreement of the ORI with PaO2 intervals in this real-life scenario were too poor to recommend the ORI as a useful early warning indicator for this age group.
Collapse
|
3
|
Video Laryngoscopy Using King Vision™ aBlade™ and Direct Laryngoscopy in Paediatric Airway Management: A Randomized Controlled Study about Device Learning by Anaesthesia Residents. J Clin Med 2022; 11:jcm11195676. [PMID: 36233540 PMCID: PMC9573319 DOI: 10.3390/jcm11195676] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Revised: 09/18/2022] [Accepted: 09/22/2022] [Indexed: 11/16/2022] Open
Abstract
Background: Airway management in children is challenging due to anatomical and physiological differences. This randomized trial investigates whether anaesthesia residents can intubate the paediatric trachea more quickly and with a higher success rate using the King Vision™ Paediatric aBlade™ video laryngoscope (KVL) compared to conventional direct laryngoscopy (DL). Methods: Eleven anaesthesia residents (mean age: 31 years, mean training status 47 months) were each asked to perform intubations with the KVL and DL in paediatric patients. The primary outcome was the first-attempt success rate. Secondary outcomes were the time to best view (TTBV), time to placement of the tracheal tube (TTP), time to ventilation (TTV), and participant-reported ease of use on a Likert scale. Results: 105 intubations with the KVL and 106 DL were performed by the residents. The success rate on the first attempt with the KVL was 81%, and the success rate on the first attempt within a given time limit of 30 s was 45%, which was lower than with DL (93% and 77% with time limit, p < 0.01). The median TTBV [IQR] on the first attempt with KVL was 7 [5−10] s, the median TTP was 28 [19−44] s, and the median TTV was 51 [39−66] s. DL-mediated intubation was significantly faster (TTP: 17 [13−23] s; p < 0.0001 and TTV: 34 [28−44] s; p < 0.001). Application of the KVL was rated as difficult or very difficult by 60% of the residents (DL: 5%). Conclusion: In contrast to promising data on the paediatric training manikin, residents took longer to intubate the airway in children with the KVL and were less successful compared to the DL. Therefore, the KVL should not be recommended for learning paediatric intubation by residents.
Collapse
|
4
|
Big data: Airway management at a university hospital over 16 years; a retrospective analysis. PLoS One 2022; 17:e0273549. [PMID: 36126076 PMCID: PMC9488754 DOI: 10.1371/journal.pone.0273549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2022] [Accepted: 08/01/2022] [Indexed: 12/02/2022] Open
Abstract
Purpose Little is known about the current practice of airway management in Germany and its development over the last decades. The present study was, therefore, designed to answer the following questions. Which airway management procedures have been performed over the last 16 years and how has the frequency of these procedures changed over time? Is there a relationship between patient characteristics or surgical specialisation and the type of airway management performed? Methods In the present study, we used our in-house data acquisition and accounting system to retrospectively analyse airway management data for all patients who underwent a surgical or medical procedure with anaesthesiological care at our tertiary care facility over the past 16 years. 340,748 airway management procedures were analysed by type of procedure, medical/surgical specialty, and type of device used. Logistic regression was used to identify trends over time. Results Oral intubation was the most common technique over 16 years (65.7%), followed by supraglottic airway devices (18.1%), nasal intubation (7.5%), mask ventilation (1.6%), tracheal cannula (1.3%), double lumen tube (0.7%), and jet ventilation (0.6%). On average, the odds ratio of using supraglottic airway devices increased by 17.0% per year (OR per year = 1.072, 95% CI = 1.071–1.088) while oral intubation rates decreased. In 2005, supraglottic airway devices were used in about 10% of all airway management procedures. Until 2020, this proportion steadily increased by 27%. Frequency of oral intubation on the other hand decreased and was about 75% in 2005 and 53% in 2020. Over time, second-generation supraglottic airway devices were used more frequently than first-generation supraglottic airway devices. While second-generation devices made up about 9% of all supraglottic airway devices in 2010, in 2020 they represented a proportion of 82%. The use of fibreoptic intubation increased over time in otorhinolaryngology and dental, oral, and maxillofacial surgery, but showed no significant trends over the entire 16-year period. Conclusion Our data represent the first large-scale evaluation of airway management procedures over a long time. There was a significant upward trend in the use of supraglottic airway devices, with an increase in the use of second-generation masks while a decrease in oral intubations was observed.
Collapse
|
5
|
Intraocular Pressure Measurement in Childhood Glaucoma under Standardized General Anaesthesia: The Prospective EyeBIS Study. J Clin Med 2022; 11:jcm11102846. [PMID: 35628971 PMCID: PMC9144815 DOI: 10.3390/jcm11102846] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2022] [Revised: 05/08/2022] [Accepted: 05/10/2022] [Indexed: 02/01/2023] Open
Abstract
Objective: We aimed to compare intraocular pressure (IOP) measurements using iCare® PRO rebound tonometry (iCare) and Perkins applanation tonometry (Perkins) in childhood glaucoma subjects and healthy children and the influence of anaesthesia depth, age and corneal thickness. Material: Prospective clinical, case-control study of children who underwent an ophthalmologic examination under general anaesthesia according to our protocol. Children were 45.45 ± 29.76 months old (mean ± SD (standard deviation)). Of all children, 54.05% were female. IOP was taken three times (T1−T3), according to duration and the depth of anaesthesia. The order of measurement alternated, starting with iCare. Agreement between the device measurements was evaluated using Bland−Altman analysis. Results: 53 glaucoma subjects and 22 healthy controls. Glaucoma subjects: IOP measured with iCare was at T1: 27.2 (18.1−33.8), T2: 21.6 (14.8−30.6), T3: 20.4 mmHg (14.5−27.0) and Perkins 17.5 (12.0−23.0), 15.5 (10.5−20.5), 15.0 mmHg (10.5−21.0) (median ± IQR (interquartile range)). Healthy controls: IOP with iCare: T1: 13.3 (11.1−17.0), T2: 10.6 (8.1−12.4), T3: 9.6 mmHg (7.7−11.7) and Perkins 10.3 (8.0−12.0), 7.0 (5.5−10.5), 7.0 mmHg (5.5−8.5) (median ± IQR). The median IOP was statistically significantly higher with iCare than with Perkins (p < 0.001) in both groups. The mean difference (iCare and Perkins) was 6.0 ± 6.1 mmHg for T1−T3, 7.3 at T1, 6.0 at T2, 4.9 mmHg at T3. Conclusion: The IOP was the highest in glaucoma subjects and healthy children at T1 (under sedation), independently of the measurement method. iCare always leads to higher IOP compared to Perkins in glaucoma and healthy subjects, regardless of the duration of anesthesia.
Collapse
|
6
|
Results of childhood glaucoma surgery over a long-term period. Acta Ophthalmol 2022; 100:e448-e454. [PMID: 34355860 DOI: 10.1111/aos.14985] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2020] [Revised: 05/23/2021] [Accepted: 07/01/2021] [Indexed: 12/26/2022]
Abstract
PURPOSE To evaluate long-term results of glaucoma surgery in newborn and infants with glaucoma. METHODS Seventy-nine eyes of 52 children (age: 3 weeks-15.3 years) with primary congenital or secondary glaucoma treated between 2015 and 2017 were included. The median follow-up time was 3.9 years. Conventional probe trabeculotomy, 360° catheter-assisted trabeculotomy, filtering and cyclodestructive surgery were compared. Strict criteria for surgical success were applied: Complete surgical success (IOP below target IOP, no further surgery) and incomplete surgical success (additional surgery allowed) were analyzed, and IOP at baseline and last follow-up was compared. RESULTS Intraocular pressure (IOP) was significantly reduced in primary congenital (preoperative IOP: 27.8 ± 7.5 mmHg vs. postoperative IOP: 14.2 ± 4.5 mmHg) and secondary glaucoma (preoperative IOP: 29.2 ± 9.1 mmHg vs. postoperative IOP: 16.6 ± 4.7 mmHg). 90% of all eyes reached target IOP with or without medication allowing for additional surgeries. As first surgery, 360° catheter-assisted trabeculotomy had a tendency to higher surgical success than other surgical approaches, while cyclodestructive procedures had lowest. CONCLUSIONS We found very promising surgical results in our childhood glaucoma patient group. Surgical success in both congenital and secondary glaucoma was high.
Collapse
|
7
|
Childhood glaucoma registry in Germany: initial database, clinical care and research (pilot study). BMC Res Notes 2022; 15:32. [PMID: 35144644 PMCID: PMC8830121 DOI: 10.1186/s13104-022-05921-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2021] [Accepted: 01/25/2022] [Indexed: 11/16/2022] Open
Abstract
Objective The aim of this prospective pilot study is to establish an initial database to register patients diagnosed with different types of childhood glaucoma and the set-up of a national registry for childhood glaucoma (ReCG) in Germany. 28 children with different types of diagnosed childhood glaucoma, who were admitted and treated at the Childhood Glaucoma Center of the University Medical Center Mainz, Germany were included. Main outcome measures were the type of childhood glaucoma, mean intraocular pressure (IOP) and genetic data of the patients. Results The documents and questionnaires for each individual included: informed consent form of the parents, medical history form of the child, patient’s gestational history questionnaire and general anesthesia examination form. Primary congenital and secondary childhood glaucoma were revealed in 11 (39%) and 17 (61%) patients, respectively. The mean IOP measured with Perkins tonometer in all patients under general anesthesia at the time of inclusion was 17.5 ± 11.8 mmHg in the right and 17 ± 8.9 mmHg in the left eyes. In 33% of children with glaucoma mutations in the CYP1B1, FOXC1, LTBP2 and TEK genes were found. The development of specific questionnaires for childhood glaucoma provides detailed baseline data to establish a ReCG in Germany for the first time. Supplementary Information The online version contains supplementary material available at 10.1186/s13104-022-05921-8.
Collapse
|
8
|
Evaluation of gender differences in postoperative sore throat and hoarseness following the use of Ambu AuraGain laryngeal mask: the randomised controlled LadyLAMA trial study protocol. BMJ Open 2022; 12:e056465. [PMID: 35105650 PMCID: PMC8808400 DOI: 10.1136/bmjopen-2021-056465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
INTRODUCTION Postoperative sore throat (POST) is a comparatively minor but very common side effect of general anaesthesia with a supraglottic airway device. The patient considers these side effects a mirror of the quality of anaesthesia. The aims of this study are to evaluate gender-specific differences in the incidence of POST and to assess whether the effects of known risk factors vary between genders. METHODS AND ANALYSIS The LadyLAMA trial is a single-centre, patient-blinded, randomised controlled trial. Consecutive patients requiring ophthalmological surgery under general anaesthesia with a second generation Ambu AuraGain laryngeal mask are randomly allocated to either cuff pressure of 45 cmH2O or cuff pressure of 60 cmH2O. We estimate the difference in POST between the genders at 20% and we hypothesised that a reduction of cuff pressure would reduce POST by 10%. A total of 800 patients will be recruited, with each subgroup including 200 patients to achieve 80% power for detecting a difference at the 5% significance level. Primary endpoints are gender differences in the incidence of POST within 24 hours postoperatively, as well as comparison of cuff pressure 45 cmH2O to 60 cmH2O with respect to POST. The main secondary objective is the effect of cuff pressure on POST stratified by gender. Further secondary endpoints are gender-specific differences in POST and hoarseness in postanaesthesia care unit (PACU) at 48 and 72 hours (or until freedom of discomfort). The parameter cuff pressure serves as key-secondary endpoint. ETHICS AND DISSEMINATION The project is approved by the local ethics committee of the Medical Association of the Rhineland Palatine state (Nr. 2021-15835). The results of this study will be made available in the form of manuscripts for publication and presentations at national and international meetings. TRIAL REGISTRATION NUMBER NCT04915534.
Collapse
|
9
|
Anaesthesia protocol evaluation of the videolaryngoscopy with the McGrath MAC and direct laryngoscopy for tracheal intubation in 1000 patients undergoing rapid sequence induction: the randomised multicentre LARA trial study protocol. BMJ Open 2021; 11:e052977. [PMID: 34615684 PMCID: PMC8496391 DOI: 10.1136/bmjopen-2021-052977] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
INTRODUCTION Rapid sequence induction of anaesthesia is indicated in patients with an increased risk of pulmonary aspiration. The main objective of the technique is to reduce the critical time period between loss of airway protective reflexes and rapid inflation of the cuff of the endotracheal tube to minimise the chance of aspiration of gastric contents. The COVID-19 pandemic has reinforced the importance of first-pass intubation success to ensure patient and healthcare worker safety. The aim of this study is to compare the first-pass intubation success rate (FPS) using the videolaryngoscopy compared with conventional direct laryngoscopy in surgical patients with a high risk of pulmonary aspiration. METHODS AND ANALYSIS The LARA trial is a multicentre, patient-blinded, randomised controlled trial. Consecutive patients requiring tracheal intubation are randomly allocated to either the McGrath MAC videolaryngoscope or direct laryngoscopy using the Macintosh laryngoscope. The expected rate of FPS is 92% in the McGrath group and 82% in the Macintosh group. Each group must include a total of 500 patients to achieve 90% power for detecting a difference at the 5% significance level. Successful intubation with the FPS is the primary endpoint. The secondary endpoints are the time to intubation, the number of intubation attempts, the necessity of airway management alternatives, the visualisation of the glottis using the Cormack and Lehane Score and the Percentage Of Glottic Opening Score and definite adverse events. ETHICS AND DISSEMINATION The project is approved by the local ethics committee of the Medical Association of the Rhineland Palatine state (registration number: 2020-15502) and medical ethics committee of the University of Freiburg (registration number: 21-1303). The results of this study will be made available in form of manuscripts for publication and presentations at national and international meetings. TRIAL REGISTRATION NCT04794764.
Collapse
|
10
|
Abstract
INTRODUCTION Neonates and young infants with diagnosed or highly suspected glaucoma require an examination under anaesthesia to achieve accurate intraocular pressure (IOP) measurements, since crying or squinting of the eyes may increase IOP and lead to falsely high values. IOP considerably depends on perioperative variables such as haemodynamic factors, anaesthetics, depth of anaesthesia and airway management. The aim of this paper is to report the design and baseline characteristics of EyeBIS, which is a study to develop a standardised anaesthetic protocol for the measurement of IOP under anaesthesia in childhood glaucoma, by investigating the link between the magnitude of IOP and depth of anaesthesia. METHODS AND ANALYSIS This is a single-centre, prospective cohort study in 100 children with diagnosed or highly suspected glaucoma all undergoing ophthalmological examination under general anaesthesia. 20 children, who undergo general anaesthesia for other reasons, are included as controls. The primary outcome measure is the establishment of a standardised anaesthetic protocol for IOP measurement in childhood glaucoma by assessing the relationship between IOP and depth of anaesthesia (calculated as an electroencephalography variable, the bispectral index), with special emphasis on airway management and haemodynamic parameters. The dependence of IOP under anaesthesia on airway management and haemodynamic parameters will be described, using a mixed linear model. Restricting the model to patients with healthy eyes will allow to determine a 95% reference region, in which 95% of the measurement values of patients with healthy eyes can be expected. ETHICS AND DISSEMINATION The study has been approved by the local ethics committee of the Medical Association of Rhineland-Palatine (Ethik-Kommisssion der Landesaerztekammer Rheinland-Pfalz), Germany (approval number: 2019-14207). This work will be disseminated by publication of peer-reviewed manuscripts, presentation in abstract form at national and international scientific meetings and data sharing with other investigators. TRIAL REGISTRATION NUMBER ClinicalTrials.gov Registry (NCT03972852).
Collapse
|
11
|
Current practice of German anesthesiologists in airway management : Results of a national online survey. Anaesthesist 2021; 71:190-197. [PMID: 34453552 DOI: 10.1007/s00101-021-01025-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2021] [Revised: 07/07/2021] [Accepted: 07/23/2021] [Indexed: 10/20/2022]
Abstract
BACKGROUND There is a worldwide consensus among experts that guidelines and algorithms on airway management contribute to improved patient safety in anesthesia. The present study aimed to determine the current practice of airway management of German anesthesiologists and assess the safety gap, defined as the difference between observed and recommended practice, amongst these practitioners. OBJECTIVE To determine the effect of implementing the guidelines on airway management practice in Germany amongst anesthesiologists and identify potential safety gaps. METHODS A survey was conducted in September 2019 by contacting all registered members of the German Society of Anaesthesiology and Intensive Care Medicine (DGAI) via email. The participants were asked about their personal and institutional background, adherence to recommendations of the current German S1 guidelines and availability of airway devices. RESULTS A total of 1862 DGAI members completed the questionnaire (response rate 17%). The main outcome was that anesthesiologists mostly adhered to the guidelines, yet certain recommendations, particularly pertaining to specifics of preoxygenation and training, showed a safety gap. More than 90% of participants had a video laryngoscope and half had performed more than 25 awake intubations using a flexible endoscope; however, only 81% had a video laryngoscope with a hyperangulated blade. An estimated 16% of all intubations were performed with a video laryngoscope, and 1 in 4 participants had performed awake intubation with it. Nearly all participants had cared for patients with suspected difficult airways. Half of the participants had already faced a "cannot intubate, cannot oxygenate" (CICO) situation and one in five had to perform an emergency front of neck access (eFONA) at least once. In this case, almost two thirds used puncture-based techniques and one third scalpel-based techniques. CONCLUSION Current practice of airway management showed overall adherence to the current German guidelines on airway management, yet certain areas need to be improved.
Collapse
|
12
|
Abstract
We present a case of awake tracheal intubation with flexible bronchoscopy which resulted in incorrect tracheal tube placement. The presence of a stenotic subglottic lesion with an appearance similar to the carina led to the tube being positioned with only the tip within the trachea whilst the cuff was located between the vocal cords. A capnography trace was identified before induction of anaesthesia; however, visual confirmation of the carina was undertaken in a rushed manner due to the patient becoming agitated. Once the incorrect tracheal tube placement was identified, the decision was made to wake the patient. Thereafter, a more experienced operator successfully performed awake tracheal intubation with flexible bronchoscopy using a smaller tracheal tube, which easily passed through the subglottic stenosis. This report emphasises the importance of performing the ‘two‐point check’ every time awake tracheal intubation is undertaken: to confirm correct tube placement, both a capnography trace and view of the tracheal lumen including the carina and main bronchi is required. This must be properly performed before induction of anaesthesia; safety should not be compromised by a stressful environment or time pressure.
Collapse
|
13
|
Non-invasive haemoglobin measurement as an index test to detect pre-operative anaemia in elective surgery patients - a prospective study. Anaesthesia 2020; 76:647-654. [PMID: 33227153 DOI: 10.1111/anae.15312] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/12/2020] [Indexed: 11/29/2022]
Abstract
Non-invasive haemoglobin measurement using absolute values lacks the precision to be the sole basis for the treatment of pre-operative anaemia. However, it can possibly serve as a screening test, indexing 'anaemia' with high sensitivity when values remain under prespecified cut-off values. Based on previous data, non-invasive haemoglobin cut-off values (146 g.l-1 for women and 152 g.l-1 for men) detect true anaemia with 99% sensitivity. An index test with these prespecified cut-off values was verified by prospective measurement of non-invasive and invasive haemoglobin pre-operatively in elective surgical patients. In 809 patients, this showed an estimated sensitivity (95%CI) of 98.9% (94.1-99.9%) in women and 96.4% (91.0-99.0%) in men. This saved invasive blood tests in 9% of female and 28% of male patients. In female patients, a lower non-invasive haemoglobin cut-off value (138 g.l-1 ) would save 28% of invasive blood tests with a sensitivity of 95%. The target 99% sensitivity would be reached by non-invasive haemoglobin cut-off values of 152 g.l-1 in female and 162 g.l-1 in male patients, saving 3% and 9% of invasive blood tests, respectively. Bias and limits of agreement between non-invasive and laboratory haemoglobin levels were 2 and - 25 to 28 g.l-1 , respectively. Patient and measurement characteristics did not influence the agreement between non-invasive and laboratory haemoglobin levels. Although sensitivity was very high, the index test using prespecified cut-off values just failed to reach the target sensitivity to detect true anaemia. Nevertheless, with respect to blood-sparing effects, the use of the index test in men may be clinically useful, while an index test with a lower cut-off (132 g.l-1 ) could be more clinically appropriate in women.
Collapse
|
14
|
Scalpel cricothyrotomy – with or without speculum: that is the question. TRENDS IN ANAESTHESIA AND CRITICAL CARE 2020. [DOI: 10.1016/j.tacc.2019.12.251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
15
|
Successful awake intubation using VivaSight-SL – An endotracheal tube with integrated camera at the top – A case report. TRENDS IN ANAESTHESIA AND CRITICAL CARE 2018. [DOI: 10.1016/j.tacc.2018.09.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
16
|
Assessment of haemoglobin measurement by several methods - blood gas analyser, capillary and venous HemoCue ® , non-invasive spectrophotometry and laboratory assay - in term and preterm infants. Anaesthesia 2018; 74:197-202. [PMID: 30427065 DOI: 10.1111/anae.14481] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/30/2018] [Indexed: 11/27/2022]
Abstract
A laboratory haematology analyser is the gold standard for measuring haemoglobin concentration but has disadvantages, especially in neonates. This study compared alternative blood-sparing and non-invasive methods of haemoglobin concentration measurement with the gold standard. Haemoglobin concentrations were measured using a laboratory haematology analyser (reference method), blood gas analyser, HemoCue® using venous and capillary blood samples and a newly developed non-invasive sensor for neonates < 3 kg. A total of 63 measurements were performed. Body weight (2190 (1820-2520 [967-4450]) g) and haemoglobin concentration (12.3 (10.6-15.2 [8.2-20.5]) g.dl-1 ) varied widely. Bias/limits of agreement between the alternative methods and reference method were -0.1/-1.2 to 1.0 g.dl-1 (blood gas analyser), -0.4/-1.8 to 1.1 g.dl-1 (HemoCue, venous blood), 0.7/-1.9 to 3.2 g.dl-1 (HemoCue, capillary blood) and -1.2/-4.3 to 2 g.dl-1 (non-invasive haemoglobin measurement). Perfusion index, body weight and fetal haemoglobin concentration did not affect the accuracy of the alternative measurement methods, and these were successfully applied in term and preterm infants. However, the accuracies of non-invasive haemoglobin measurement and HemoCue of capillary blood especially lacked sufficient agreement with that of the reference method to recommend these methods for clinical decision making.
Collapse
|
17
|
A comparison of two hyperangulated video laryngoscope blades to direct laryngoscopy in a simulated infant airway: a bicentric, comparative, randomized manikin study. BMC Anesthesiol 2018; 18:119. [PMID: 30170540 PMCID: PMC6119241 DOI: 10.1186/s12871-018-0580-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2018] [Accepted: 08/14/2018] [Indexed: 11/20/2022] Open
Abstract
Background In infants, securing the airway is time-critical because of anatomical and physiological differences related to airway management in children less than 1 year old. The aim of this study was to compare the time to ventilation using two different hyperangulated video laryngoscope blades with the time to ventilation via conventional direct laryngoscopy in a normal airway [NA] and in a simulated difficult airway [DA]. Methods This study was a comparative, bicentric, open-label, randomized controlled evaluation. An infant high-fidelity simulator (SimBaby™; Laerdal® Medical, Stavanger, Norway) was used, and two scenarios were proposed, as follows: NA and DA evoked with tongue edema and cervical collar. After theoretical and practical briefing, each participant compared in the two airway scenarios the novel King Vision™ Pediatric aBlade (KV) (Ambu® A/S, Bad Nauheim, Germany) video laryngoscope and the C-MAC™ D-blade Ped (DB) (Karl Storz® SE & Co. KG, Tuttlingen, Germany) video laryngoscope to conventional laryngoscopy using the Miller Blade (MiB) and the Macintosh Blade (MaB) in a random sequence. Results Eighty physicians (65 AN and 15 PCCM staff) were included. In the NA scenario, the median [IQR] time to successful time to ventilation (TTV) was significantly shorter for the KV at 13 s [12–15 s] than for the MaB at 14.5 s [13–16 s], DB at 14.5 s [13–16] and MiB at 16 s [14–19] (p < 0.001). In DA, the KV also shortened TTV to 14 s [13–16], whereas TTV was 23 s with the MaB [20–26], 19 s with the DB [16–21], and 27 s with the MiB [22–31] (p < 0.001). There were no differences in first-pass intubation success rates (FPAs) between hyperangulated blades and direct laryngoscopes in NA. In DA, the hyperangulated blades enabled 92 (DB) to 100% (KV) FPAs compared with 65 (MiB) to 76% (MaB) for conventional laryngoscopy (p < 0.001). Conclusion Video laryngoscopes with hyperangulated blades were associated with shorter TTV in normal and difficult infant airway situations. The higher FPAs of hyperangulated blades in DA may avoid desaturations and decrease adverse events in pediatric airway management. Electronic supplementary material The online version of this article (10.1186/s12871-018-0580-y) contains supplementary material, which is available to authorized users.
Collapse
|
18
|
Red blood cell transfusion in perioperative pediatric anesthesia: a survey of current practice in Germany. Transfusion 2018; 58:1597-1605. [DOI: 10.1111/trf.14581] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2017] [Revised: 01/19/2018] [Accepted: 02/06/2018] [Indexed: 12/23/2022]
|
19
|
Topical Airway Anesthesia for Awake-endoscopic Intubation Using the Spray-as-you-go Technique with High Oxygen Flow. J Vis Exp 2017. [PMID: 28117793 DOI: 10.3791/55116] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
A patient's willingness to cooperate is an absolute precondition for successful awake intubation of the trachea. Whilst drug-sedation of patients can jeopardize their spontaneous breathing, topical anesthesia of the airway is a popular technique. The spray-as-you-go technique represents one of the simplest opportunities to anesthetize the airway mucosa. The application of local anesthetic through the working channel of the flexible endoscope is a widespread practice for anesthetists as well as pulmonologists. There is neither need for additional devices nor special training as a pre-requisite to perform this technique. However, a known clinical problem is the coughing and gagging reflex that may occur when the liquid anesthetic strikes the airway mucosa and other sensitive structures like the vocal cords. This can be avoided by the use of oxygen applied through the working channel with the aim of fogging the local anesthetic into finer particles. Furthermore, the oxygen flow provides a higher oxygen supply and contributes to a better view, dispersing mucus secretions and blood away from the lens. Using an atomizer with a high oxygen flow of 10 L/min we maximized these benefits, caused less coughing and had more satisfied and therefore cooperative patients. Possible, but very rare complications of using oxygen flow including gastric insufflation, organ rupture or barotrauma did not arise. We attribute the complication-free use of high oxygen flow to the design of the set, which permits flow and pressure release.
Collapse
|
20
|
Airway topical anaesthesia for awake fibreoptic intubation - a reply. Anaesthesia 2016; 71:1490-1491. [DOI: 10.1111/anae.13663] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
21
|
|
22
|
A comparison of the Enk Fiberoptic Atomizer Set(™) with boluses of topical anaesthesia for awake fibreoptic intubation. Anaesthesia 2016; 71:814-22. [PMID: 27150724 DOI: 10.1111/anae.13496] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/22/2016] [Indexed: 01/04/2023]
Abstract
We compared the Enk Fiberoptic Atomizer Set(™) with boluses of topical anaesthesia administered via the working channel during awake fibreoptic tracheal intubation in 96 patients undergoing elective surgery. Patients who received topical anaesthesia via the atomiser, compared with boluses via the fibreoptic scope, reported a better median (IQR [range]) level of comfort: 1 (1-3 [1-10]) vs. 4 (2-6 [1-10]), p < 0.0001; experienced a reduced total number of coughs: 6 (3-10 [0-34]) vs. 11 (6-13 [0-25]), p = 0.0055; and fewer distinct coughing episodes: 7% vs. 27% respectively, p = 0.0133. The atomiser technique was quicker: 5 (3-6 [2-12]) min vs. 6 (5-7 [2-15]) min, p = 0.0009; and required less topical lidocaine: 100 mg (100-100 [80-160]) vs. 200 mg (200-200 [200-200]), p < 0.0001. Four weeks after nasal intubation, the incidence of nasal pain was less in the atomiser group compared with the control group (8% vs. 50%, p = 0.0015). We conclude that the atomiser was superior to bolus application for awake fibreoptic tracheal intubation.
Collapse
|
23
|
[Indirect laryngoscopy/video laryngoscopy. A review of devices used in emergency and intensive care medicine in Germany]. Med Klin Intensivmed Notfmed 2012; 107:521-30. [PMID: 22926584 DOI: 10.1007/s00063-012-0090-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2012] [Accepted: 08/01/2012] [Indexed: 10/27/2022]
Abstract
Airway management in intensive care or emergency medicine is particularly challenging and is often associated with life-threatening complications. An innovation in the field of airway management is the use of indirect laryngoscopy by means of video laryngoscopes. A digital camera or an optical system at the tip of a laryngoscope blade enables an indirect "look around the corner" to the glottis. Studies have shown that the advantages of video laryngoscopes for endotracheal intubation are particularly beneficial in difficult airway situations. However, the successful use in challenging intubations requires experience and regular use in daily practice. This review gives an overview of indirect laryngoscopes commonly used in Germany and also presents new study results for these novel devices.
Collapse
|