Flash Glucose Monitoring and Diabetes Mellitus Induced by Immune Checkpoint Inhibitors: An Approach to Clinical Practice.
J Diabetes Res 2022;
2022:4508633. [PMID:
36387939 PMCID:
PMC9652069 DOI:
10.1155/2022/4508633]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 09/01/2022] [Accepted: 10/19/2022] [Indexed: 11/06/2022] Open
Abstract
OBJECTIVES
The aim of this study is to investigate in depth diabetes mellitus associated with immune checkpoint inhibitors (DM-ICIs) by analysing a case series. We also evaluated the clinical impact of flash glucose monitoring (FGM) systems in the management of this entity.
METHODS
We conducted an observational cohort study of DM-ICIs diagnosed in two hospitals in Seville (Spain). Patients with a new diagnosis of diabetes mellitus (DM) or with sudden worsening of preexisting DM after starting treatment with ICIs, with a random 5 hour-postprandial C-peptide value of <0.6 nmol/L and without possibility of subsequent withdrawal of insulin treatment, were included.
RESULTS
A total of 7 cases were identified, mostly males (n = 6; 85.7%), with a mean age of 64.9 years. The mean glycated hemoglobin (HbA1c) upon diagnosis was 8.1%, with diabetic ketoacidosis (DKA) observed in 6 cases (85.7%). Subcutaneous flash glucose monitoring (FGM) systems were used in six cases, with a mean follow-up period of 42.7 weeks. During the first 90 days of use, mean average glucose was 167.5 mg/dL, with a coefficient of variation (CV) of 34.6%. The mean time in the range 70-180 mg/dL (TIR) was 59.7%, with a mean time above range (TAR) 181-250 mg/dL of 27.8% and a mean TAR > 250 mg/dL of 10.2%. The mean time below range (TBR) 54-69 mg/dL was 2%, while the mean TBR < 54 mg/dL was 0.3%. The mean glucose management indicator (GMI) was 7.3%. No significant differences were observed in FGM values for the following 90 days of follow-up. A progressive improvement in all parameters of glycaemic control was observed between the first month of FGM use and the sixth month of FGM use. Of note, there was a decrease in mean CV (40.6% to 34.1%, p = 0.25), mean TAR 181-250 (30.3% to 26%, p = 0.49), mean TAR > 250 mg/dL (16.3% to 7.7%, p = 0.09), mean TBR 54-69 mg/dL (5.2% to 2%, p = 0.16), and mean TBR < 54 mg/dL (1.8% to 0.2%, p = 0.31), along with an increase in mean values of TIR 70-180 mg/dL (46.5% to 60.5%, p = 0.09). The lack of statistical significance in the differences observed in the mean FGM values over the follow-up period may be related to the small sample size.
CONCLUSION
DM-ICI is recognised by a state of sudden-onset insulinopenia, often associated with DKA. The use of FGM systems may be a valid option for the effective management of DM-ICIs and for the prevention of severe hyperglycaemic and hypoglycaemic episodes in this condition.
Collapse