1
|
Cox Z, Zalawadiya S, Simonato M, Redfors B, Zhou Z, Kotinkaduwa L, Zile M, Udelson J, Lim DS, Grayburn PA, Mack MJ, Abraham WT, Stone GW, Lindenfeld J. Maximally tolerated guideline-directed medical therapy and barriers to optimization in patients with heart failure with reduced ejection fraction: the COAPT trial. Eur Heart J 2022. [DOI: 10.1093/eurheartj/ehac544.975] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Background
The COAPT trial of MitraClip therapy employed a central screening eligibility committee (CSEC) of heart failure (HF) experts to ensure the use of maximally tolerated guideline-directed medical therapy (GDMT) and systematically document intolerances in all potential patients prior to approval for randomization.
Purpose
To describe the percentage of GDMT classes, doses tolerated, predictors of intolerance, and specific intolerances limiting GDMT among patients approved for randomization by the CSEC.
Methods
We analyzed baseline use, dose, and intolerances of i) angiotensin-converting enzyme inhibitors (ACEI), angiotensin II receptor blockers (ARB) or angiotensin receptor neprilysin inhibitor (ARNI); ii) beta-blockers (BB); and iii) mineralocorticoid receptor antagonists (MRA) in the CSEC-approved COAPT population with HF with reduced ejection fraction (HFrEF; LVEF ≤40%). We analyzed variables associated with GDMT tolerance.
Results
In COAPT, 464 patients had HFrEF and complete screening medication information. Any dose of all 3, 2 or 1 GDMT classes were tolerated in 39%, 39% and 20% of patients respectively; only 2% of patients (n=9) could not tolerate any GDMT (Figure 1). BB were prescribed in the most (93%) patients followed by ACEI/ARB/ARNI (69%) and MRA (55%). Intolerances limiting each GDMT class differed, but hypotension and kidney dysfunction were most common (Figure 2). No patients tolerated goal doses of all 3 GDMT classes. For BB, only 32% tolerated ≥50% of the goal dose; while for ACEI/ARB/ARNI, no patients achieved goal doses, and only 1% tolerated ≥50% of the goal dose. For MRA, 86% of patients tolerated 25mg/day or less. Patients intolerant of BB were less likely to tolerate an ACEI/ARB/ARNI (OR 0.39, 95% CI 0.20–0.76; p=0.004) but not a MRA (p=0.21) compared with patients tolerating a low dose BB. Patients intolerant of MRA were less likely to tolerate ACEI/ARB/ARNI therapy (OR 0.37, 95% CI 0.25–0.57; p<0.0001) but not a BB (p=0.31) compared with patients tolerating MRA. Patients tolerating low dose ACEI/ARB/ARNI had a higher baseline mean eGFR (52±21 versus 40±21 ml/min/m2; p<0.0001) compared with patients intolerant of ACEI/ARB/ARNI. Likewise, patients tolerating MRA had a higher baseline mean eGFR (52±21 versus 42±21 ml/min/m2; p<0.0001) compared with patients intolerant of MRA.
Conclusion
In a contemporary trial in which HF specialists ensured GDMT optimization, many patients had medical intolerances prohibiting use of one or more GDMT classes, and few patients tolerated target doses. These findings indicate medical intolerances are the primary cause of low GDMT prescription rates in patients with moderate to severe HFrEF. Yet, use of GDMT in this very ill population was much better than “real world” registries of HFrEF suggesting that mandating careful CSEC review prior to study enrollment is important for clinical trials having the objective of randomizing a maximally treated patient cohort.
Funding Acknowledgement
Type of funding sources: None.
Collapse
|
2
|
Shimoda M, Itoh T, Sugimoto K, Takita M, Chujo D, Iwahashi S, SoRelle JA, Naziruddin B, Levy MF, Grayburn PA, Matsumoto S. An effective method to release human islets from surrounding acinar cells with agitation in high osmolality solution. Transplant Proc 2014; 43:3161-6. [PMID: 22099746 DOI: 10.1016/j.transproceed.2011.09.098] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
Abstract
INTRODUCTION Islet purification is mainly performed by the density gradient method. However, purification of the embedded islets that are surrounded by exocrine tissue should be difficult, because their density is similar to exocrine tissue. In this study, we performed chart review to assess the relationship between the ratio of embedded islets and efficacy of purification. Then, we tested several conditions of a new method to free the islets from surrounded exocrine tissues using high osmolality solution with gentle agitation. MATERIALS AND METHODS First, we performed chart review of our human islet isolation. Second, embedded islet-enriched human islet fractions (embedded islets >50%) were suspended in University of Wisconsin (UW) solution (UW group, 320 mOsm/kg/H(2)0) or osmolality-adjusted UW solution (400, 500, and 600 mOsm/kg/H(2)0; 400 group, 500 group, and 600 group, respectively). Each tube was gently shaken at 4°C. The tissue samples were taken before shaking and after 15, 30, and 60 minutes. Islet yield, percentage of embedded islets, and viabilities were assessed. RESULTS The chart review revealed that high ratio of embedded islets deteriorated the efficacy of islet purification. The islet yield in all groups except for the 600 group did not change at 15 minutes, but it decreased in all groups at 60 minutes. The average percentage of embedded islets before shaking was 62.6%. Although percentage of embedded islets were decreasing in all groups, it was < 20% at 15 minutes in the 500 and 600 groups whereas it was >44% in the UW group, which indicated that higher osmolality would have a greater effect. Viability was >95% in all groups at 30 minutes. CONCLUSIONS The embedded islets deteriorated the efficacy of islet purification. Gentle agitation of embedded islets in high osmolality (500 mOsm/kg/H(2)O, 15 minutes) could release islets from surrounded exocrine tissue.
Collapse
|
3
|
Chen S, Shimoda M, Chen J, Grayburn PA. Stimulation of adult resident cardiac progenitor cells by durable myocardial expression of thymosin beta 4 with ultrasound-targeted microbubble delivery. Gene Ther 2012; 20:225-33. [DOI: 10.1038/gt.2012.89] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|
4
|
Shimoda M, Noguchi H, Naziruddin B, Fujita Y, Chujo D, Takita M, Peng H, Tamura Y, Olsen GS, Sugimoto K, Itoh T, Onaca N, Levy MF, Grayburn PA, Matsumoto S. Assessment of human islet isolation with four different collagenases. Transplant Proc 2011; 42:2049-51. [PMID: 20692404 DOI: 10.1016/j.transproceed.2010.05.093] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
BACKGROUND The isolation of islets from the human pancreas critically depends on the efficiency of the digestive enzymes. Liberase HI had been used as a standard preparation until the issues concerning bovine spongiform encephalopathy. Thus, we must now use other collagenases for clinical islet transplantation, four of which we have evaluated herein. METHODS The digestion of each of 17 pancreata from brain-dead donors was performed using the following collagenases: Liberase HI (HI; Roche, n = 9); Liberase MTF C/T (MTF; Roche, n = 4); Collagenase NB1 Premium Grade (NB1; Serva, n = 7); or Clzyme Collagenase HA (CI, VitaCyte, n = 4). Islet isolations were based on the Edmonton protocol for HI, whereas our modified islet isolation method was used for the three new enzymes (MTF, NB1, and CI). RESULTS There were no significant differences in donor age, body mass index, pancreas size, and cold ischemic time among the four groups. The phase I time in the NB1 group was significantly shorter than in the CI group (P = .0014). The prepurification IEQ/g in the HI group was significantly lower than the others (P = .0003 vs MTF, .0007 vs NB1, and .0009 vs CI, respectively). The postpurification IEQ/g in the MTF group was significantly higher than in the HI group (P = .006). The viability in the NB1 group was significantly greater than the HI group (P = .003). CONCLUSION Three new enzymes (MTF, NB1, and CI) may enable us to obtain higher islet yields than with HI.
Collapse
|
5
|
Shimoda M, Chen S, Noguchi H, Matsumoto S, Grayburn PA. In vivo non-viral gene delivery of human vascular endothelial growth factor improves revascularisation and restoration of euglycaemia after human islet transplantation into mouse liver. Diabetologia 2010; 53:1669-79. [PMID: 20405100 PMCID: PMC3804430 DOI: 10.1007/s00125-010-1745-5] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2010] [Accepted: 03/03/2010] [Indexed: 10/19/2022]
Abstract
AIMS/HYPOTHESIS Delivery of the gene for human vascular endothelial growth factor (VEGF, also known as VEGFA) to both the transplanted islets and the surrounding tissue may promote islet revascularisation and survival. We previously showed the effective delivery of VEGF gene to rat myocardium by an ultrasound-mediated gene-transfer method named ultrasound-targeted microbubble destruction (UTMD). Here we examined the effect of non-viral VEGF delivery using UTMD on transplanted islets in vivo. METHODS A marginal number of human islets were transplanted into livers of mice which were a model for diabetes. Then, non-viral plasmid vectors encoding VEGF (VEGF group, n = 11) or the gene for green fluorescent protein (GFP) (GFP group, n = 7) were introduced into the host liver by UTMD. Transplantation without gene delivery was performed as a control (no-UTMD group, n = 8). Blood glucose, serum human insulin, C-peptide levels and the revascularisation in graft islets were evaluated. RESULTS Restoration of euglycaemia occurred in 13% in the no-UTMD group and 14% in the GFP group, whereas 73% mice in the VEGF group became euglycaemic at day 30 (p < 0.05 in no-UTMD vs VEGF). Serum human insulin and C-peptide were significantly higher in the VEGF group at day 32 (insulin: no-UTMD, 17 +/- 8; GFP, 37 +/- 17; VEGF, 109 +/- 26 pmol/l, respectively, p < 0.05; C-peptide: no-UTMD, 68 +/- 38; GFP, 115 +/- 58; VEGF, 791 +/- 230 pmol/l, respectively, p < 0.05). Vessel density in graft islets was significantly higher in the VEGF group (no-UTMD, 169 +/- 36; GFP, 227 +/- 39; VEGF, 649 +/- 51 counts/mm(2), respectively, p < 0.05). CONCLUSIONS/INTERPRETATION Delivery of VEGF gene to host liver using UTMD promoted islet revascularisation after islet transplantation and improved the restoration of euglycaemia.
Collapse
|
6
|
Chen S, Ding J, Yu C, Yang B, Wood DR, Grayburn PA. Reversal of streptozotocin-induced diabetes in rats by gene therapy with betacellulin and pancreatic duodenal homeobox-1. Gene Ther 2007; 14:1102-10. [PMID: 17460716 DOI: 10.1038/sj.gt.3302963] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Ultrasound-targeted microbubble destruction (UTMD) was used to direct betacellulin (BTC) and pancreatic duodenal homeobox-1 (PDX1) to rat pancreas 48 h after islet destruction by streptozotocin (STZ). Sprague-Dawley rats were rendered diabetic by STZ injection. Controls included normal rats, STZ only without UTMD, and UTMD with DsRed reporter gene. Blood glucose increased dramatically in all rats 48 h after STZ, and continued to rise after UTMD with BTC alone. Blood glucose declined from day 3 to day 10 after UTMD with PDX1, but remained elevated (261+/-8 mg/dl). However, in rats treated with both BTC and PDX1, blood glucose remained below 200 mg/dl throughout day 10. This was accompanied by normalization of blood insulin and C-peptide. Histology demonstrated islet-like clusters of glucagon-staining cells in the rats treated with BTC and PDX1, but these clusters disappeared by 30 days after UTMD treatment. Although regeneration of insulin-producing islets was not seen, diabetes was reversed for up to 15 days after a single UTMD treatment by ectopic insulin production by pancreatic acinar cells. These cells co-expressed amylase and insulin and demonstrated several beta-cell markers by reverse transcription-PCR. Gene therapy by UTMD can reverse diabetes in vivo in adult rats by restoring pancreatic insulin production.
Collapse
|
7
|
Korpanty G, Chen S, Shohet RV, Ding J, Yang B, Frenkel PA, Grayburn PA. Targeting of VEGF-mediated angiogenesis to rat myocardium using ultrasonic destruction of microbubbles. Gene Ther 2005; 12:1305-12. [PMID: 15829992 DOI: 10.1038/sj.gt.3302532] [Citation(s) in RCA: 91] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Myocardial angiogenesis mediated by human vascular endothelial growth factor 165 (hVEGF165) cDNA was promoted in rat myocardium using an in vivo-targeted gene delivery system known as ultrasound-targeted microbubble destruction (UTMD). Microbubbles carrying plasmids encoding hVEGF165, or control solutions were infused intravenously during ultrasonic destruction of the microbubbles within the myocardium. Biochemical and histological assessment of gene expression and angiogenesis were performed 5, 10, and 30 days after UTMD. UTMD-treated myocardium contained hVEGF165 protein and mRNA. The myocardium of UTMD-treated animals showed hypercellular foci associated with hVEGF165 expression and endothelial cell markers. Capillary density in UTMD-treated rats increased 18% at 5 days and 33% at 10 days, returning to control levels at 30 days (P<0.0001). Similarly, arteriolar density increased 22% at 5 days, 86% at 10 days, and 31% at 30 days (P<0.0001). Thus, noninvasive delivery of hVEGF165 to rat myocardium by UTMD resulted in significant increases in myocardial capillary and arteriolar density.
Collapse
|
8
|
Abstract
The assessment of perfusion by myocardial contrast echocardiography has evolved from the early contrast agents, including agitated saline solutions and hydrogen peroxide, to the current second-generation contrast agents. Unlike the first-generation contrast agents, which are composed of air, the newer, second-generation agents contain gases with a higher molecular weight and less solubility and diffusivity, improving microbubble persistence. The newer contrast agents are capable of transpulmonary passage and opacification of the left-heart chambers and the myocardial microcirculation after intravenous administration. Also, innovative imaging techniques using harmonics and triggered imaging have minimized tissue signal and improved signal-to-noise ratio, making the assessment of myocardial perfusion possible. Currently, microbubbles are being designed for specific research or clinical use by exploiting certain characteristics of the microbubble such as the shell, surface characteristics, and/or gas content. Some novel applications of microbubble technology include tissue-targeted gene therapy, drug delivery, ultrasound-enhanced thrombolysis, and the assessment of endothelial function and integrity. This review focuses on the composition, physical properties, and acoustic characteristics of the currently available myocardial contrast agents and those under clinical investigation. In addition, the clinical trials involving these agents will also be discussed.
Collapse
|
9
|
Willett DL, Hall SA, Jessen ME, Wait MA, Grayburn PA. Assessment of aortic regurgitation by transesophageal color Doppler imaging of the vena contracta: validation against an intraoperative aortic flow probe. J Am Coll Cardiol 2001; 37:1450-5. [PMID: 11300460 DOI: 10.1016/s0735-1097(01)01114-7] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
OBJECTIVES This study was performed to validate the accuracy of color flow vena contracta (VC) measurements of aortic regurgitation (AR) severity by comparing them to simultaneous intraoperative flow probe measurements of regurgitant fraction (RgF) and regurgitant volume (RgV). BACKGROUND Color Doppler imaging of the vena contracta has emerged as a simple and reliable measure of the severity of valvular regurgitation. This study evaluated the accuracy of VC imaging of AR by transesophageal echocardiography (TEE). METHODS A transit-time flow probe was placed on the ascending aorta during cardiac surgery in 24 patients with AR. The flow probe was used to measure RgF and RgV simultaneously during VC imaging by TEE. Flow probe and VC imaging were interpreted separately and in blinded fashion. RESULTS A good correlation was found between VC width and RgF (r = 0.85) and RgV (r = 0.79). All six patients with VC width >6 mm had a RgF >0.50. All 18 patients with VC width <5 mm had a RgF <0.50. Vena contracta area also correlated well with both RgF (r = 0.81) and RgV (r = 0.84). All six patients with VC area >7.5 mm2 had a RgF >0.50, and all 18 patients with a VC area <7.5 mm2 had a RgF <0.50. In a subset of nine patients who underwent afterload manipulation to increase diastolic blood pressure, RgV increased significantly (34 +/- 26 ml to 41 +/- 27 ml, p = 0.042) while VC width remained unchanged (5.4 +/- 2.8 mm to 5.4 +/- 2.8 mm, p = 0.41). CONCLUSIONS Vena contracta imaging by TEE color flow mapping is an accurate marker of AR severity. Vena contracta width and VC area correlate well with RgF and RgV obtained by intraoperative flow probe. Vena contracta width appears to be less afterload-dependent than RgV.
Collapse
|
10
|
Laskar R, Grayburn PA. Assessment of myocardial perfusion with contrast echocardiography at rest and with stress: an emerging technology. Prog Cardiovasc Dis 2000; 43:245-58. [PMID: 11153511 DOI: 10.1053/pcad.2000.19802] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Over the past 20 years, there has been considerable progress in the field of myocardial contrast echocardiography (MCE). What began as a modality limited to selected cardiac catherization laboratories may soon become a rapid and accurate bedside tool for assessing myocardial perfusion. Because MCE via intravenous contrast injection can be performed at the bedside and avoids the use of radiation exposure, it offers multiple potential clinical applications, including assessment of reperfusion after fibrinolytic therapy, postinfarction risk area, and myocardial viability. The addition of perfusion data to wall motion may augment the results of stress echocardiography. This report describes the technologic advances in contrast agents and related imaging technologies that enable myocardial perfusion to be assessed by echocardiography. In addition, the latest clinical studies of myocardial perfusion by MCE are presented.
Collapse
|
11
|
Grayburn PA. Vasodilator therapy for chronic aortic and mitral regurgitation. Am J Med Sci 2000; 320:202-8. [PMID: 11014375] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2023]
Abstract
The use of vasodilator therapy in chronic AR and MR may be beneficial in selected patients and harmful in others. The hemodynamics of the two conditions are different and must be taken into account. In AR, vasodilators reduce afterload mismatch and can preserve LV function and delay the need for surgery. However, if the patient has severely reduced diastolic blood pressure, vasodilators could potentially impair coronary perfusion. In MR, vasodilators may reduce regurgitant volume and LV preload depending on the mechanism of MR. In patients with MR caused by dilated cardiomyopathy, vasodilators reduce symptoms, and improve functional class. However, in mitral valve prolapse or hypertrophic cardiomyopathy, vasodilators may worsen the MR and should be avoided. In other primary causes of MR, vasodilators could potentially mask the development of LV dysfunction and lead to unnecessary and harmful delays in surgery.
Collapse
|
12
|
Spencer KT, Grayburn PA, Mor-Avi V, Bednarz J, Grimm RA, Furlong K, Farnum RF, Floer SD, Widner PJ, Lang RM. Myocardial contrast echocardiography with power Doppler imaging. Am J Cardiol 2000; 86:479-81. [PMID: 10946053 DOI: 10.1016/s0002-9149(00)00975-9] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
13
|
Chen S, Wang Z, Zhou YT, Grayburn PA. Optimization of the size distribution and myocardial contrast effect of perfluorocarbon-filled albumin microbubbles by lyophilization under continuous negative pressure. J Am Soc Echocardiogr 2000; 13:748-53. [PMID: 10936818 DOI: 10.1067/mje.2000.104644] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
This study was undertaken to evaluate the effect of lyophilization under continuous negative pressure on perfluoropropane-filled albumin microbubble size distribution and myocardial contrast effect. Three different microbubble preparations were studied: (1) 1% albumin solution without a sugar (Optison), (2) 1% albumin and 5% dextrose (PESDA), and (3) 1% albumin and 5% fructose (PESFA). The 2 preparations containing sugar were also subjected to lyophilization under continuous negative pressure. Microbubble size distribution was measured with a Coulter Multisizer II (Beckman Coulter, Inc, Fullerton, Calif). The microbubbles were injected intravenously into a rat during intravital microscopy of the mesenteric microcirculation. Finally, the different albumin microbubbles were injected intravenously into 10 dogs, and myocardial contrast effect was assessed by videodensitometry. Results of the Coulter counter studies showed lyophilized PESFA to have a smaller size distribution with 99.9% + or - 0.1% of microbubbles <10 microm in diameter and 88.5% + or - 1.4% <4 microm in diameter (P <.05 compared with Optison or PESDA). On intravital microscopy, PESFA microbubbles behaved as intravascular tracers without microvascular plugging or coalescence. Finally, myocardial peak gray scale and area under the curve were significantly higher for PESFA than for PESDA or Optison, respectively. In conclusion, lyophilization of perfluoropropane-filled albumin microbubbles results in smaller microbubbles with a more uniform size distribution and brighter myocardial contrast. In addition, the substitution of fructose for dextrose improves size distribution and contrast effect. These findings have important implications regarding the use of novel imaging technologies that take advantage of microbubble destruction to image myocardial perfusion.
Collapse
|
14
|
Heinle SK, Noblin J, Goree-Best P, Mello A, Ravad G, Mull S, Mammen P, Grayburn PA. Assessment of myocardial perfusion by harmonic power Doppler imaging at rest and during adenosine stress: comparison with (99m)Tc-sestamibi SPECT imaging. Circulation 2000; 102:55-60. [PMID: 10880415 DOI: 10.1161/01.cir.102.1.55] [Citation(s) in RCA: 128] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Harmonic power Doppler imaging (HPDI) is a novel technique for assessing myocardial perfusion by contrast echocardiography in humans. The purpose of this study was to compare myocardial perfusion by HPDI with that obtained by (99m)Tc-sestamibi single photon emission computed tomography (SPECT) during rest and pharmacological stress. METHODS AND RESULTS HPDI was performed on 123 patients who were referred for SPECT imaging for known or suspected coronary artery disease. Images were obtained at baseline and during adenosine infusion (0.14 mg. kg(-)(1). min(-)(1)x6 minutes) in 3 apical views. Myocardial perfusion by HPDI was graded for each coronary territory as absent, patchy, or full. The persistence of absent or patchy myocardial perfusion by HPDI between rest and adenosine was interpreted as a fixed defect, whereas any decrease in perfusion grade was interpreted as a reversible defect. Overall concordance between HPDI and SPECT was 83 (81%) of 103 for normal versus abnormal perfusion. Agreement between the 2 methods for each of the 3 coronary territories was 81% (kappa=0.57) for the left anterior descending artery, 76% (kappa=0.52) for the right coronary artery, and 72% (kappa=0.40) for the left circumflex artery. Discrepancies between the 2 techniques were most notable in the circumflex territory, where fixed defects were observed in 33% by HPDI but in only 14% by SPECT (chi(2)=15.8, P=0.0001). CONCLUSIONS This study demonstrates that HPDI can reliably detect myocardial perfusion during pharmacological stress, although there was a significantly higher number of falsely abnormal results in the circumflex territory.
Collapse
|
15
|
Shohet RV, Chen S, Zhou YT, Wang Z, Meidell RS, Unger RH, Grayburn PA. Echocardiographic destruction of albumin microbubbles directs gene delivery to the myocardium. Circulation 2000; 101:2554-6. [PMID: 10840004 DOI: 10.1161/01.cir.101.22.2554] [Citation(s) in RCA: 306] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND The noninvasive, tissue-specific delivery of therapeutic agents to the heart would be a valuable clinical tool. This study addressed the hypothesis that albumin-coated microbubbles could be used to effectively deliver an adenoviral transgene to rat myocardium by ultrasound-mediated microbubble destruction. METHODS AND RESULTS Recombinant adenovirus containing beta-galactosidase and driven by a constitutive promoter was attached to the surface of albumin-coated, perfluoropropane-filled microbubbles. These bubbles were infused into the jugular vein of rats with or without simultaneous echocardiography. Additional controls included ultrasound of microbubbles that did not contain virus, virus alone, and virus plus ultrasound. One group underwent ultrasound-mediated destruction of microbubbles followed by adenovirus infusion. Rats were killed after 4 days and examined for beta-galactosidase expression. The hearts of all rats that underwent ultrasound-mediated destruction of microbubbles containing virus showed nuclear staining with 5-bromo-4-chloro-3-indolyl-beta-D-galactopyranoside substrate, indicating expression of the transgene. None of the control animals showed myocardial expression of the beta-galactosidase transgene. By quantitative analysis, beta-galactosidase activity was 10-fold higher in the treated group than in controls (P<0.0001). CONCLUSIONS Ultrasound-mediated destruction of albumin-coated microbubbles is a promising method for the delivery of bioactive agents to the heart.
Collapse
|
16
|
DiCorte CJ, Latham P, Greilich PE, Cooley MV, Grayburn PA, Jessen ME. Esophageal Doppler monitor determinations of cardiac output and preload during cardiac operations. Ann Thorac Surg 2000; 69:1782-6. [PMID: 10892923 DOI: 10.1016/s0003-4975(00)01129-2] [Citation(s) in RCA: 79] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
BACKGROUND Perioperative management of cardiac surgical patients frequently mandates measurements of cardiac output and left ventricular filling. This study compared cardiac output and left ventricular filling measured by pulmonary artery (PA) catheter and esophageal Doppler monitor (EDM). METHODS Thirty-four patients undergoing coronary artery bypass grafting were prepared by implanting a PA catheter, an EDM, and a transit-time ultrasonic flow probe around the ascending aorta. In 20 patients, left ventricular end-diastolic short-axis area (EDA) was measured by transesophageal echocardiography. At five time points, cardiac output was measured from the flow probe, the EDM, and the PA catheter (by thermodilution), and left ventricular filling was assessed from the PA catheter (as PA diastolic pressure), the EDM (corrected flow time), and the EDA. For cardiac output, concordance correlations relating EDM to flow probe and PA catheter to flow probe were calculated, transformed (Fisher's z transformation), and compared by Student's t test. For left ventricular filling, regression coefficients were created between corrected flow time and EDA and between PA diastolic pressure and EDA. Spearman correlations were compared by Wilcoxon rank sum test. RESULTS The EDM and the PA catheter exhibited similar relationships to the flow probe (concordance correlations, 0.55 +/- 0.35 [mean +/- standard deviation] and 0.49 +/- 0.34, respectively; p = 0.088). The correlation between corrected flow time and EDA was better than the correlation between PA diastolic pressure and EDA (concordance correlations, 0.49 +/- 0.55 versus 0.10 +/- 0.43, respectively; p < 0.01). CONCLUSIONS These data suggest that the EDM may offer a less invasive technique for evaluating cardiac output and a more accurate estimate for preload compared with the PA catheter.
Collapse
|
17
|
Eichhorn EJ, Grayburn PA. beta-blocker improvement in diastolic performance: the yin and yang of ventricular function changes. Am Heart J 2000; 139:584-6. [PMID: 10740138 DOI: 10.1016/s0002-8703(00)90034-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
18
|
|
19
|
Hundley WG, Kizilbash AM, Afridi I, Franco F, Peshock RM, Grayburn PA. Effect of contrast enhancement on transthoracic echocardiographic assessment of left ventricular regional wall motion. Am J Cardiol 1999; 84:1365-8, A8-9. [PMID: 10614810 DOI: 10.1016/s0002-9149(99)00577-9] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The use of contrast-enhanced transthoracic echocardiography to evaluate left ventricular regional wall motion was determined by comparison of echocardiographic data with assessments obtained by magnetic resonance imaging. When left ventricular endocardial segments are well visualized after contrast enhancement, the ability to determine normal versus abnormal endocardial thickening with echocardiography is similar to cine magnetic resonance imaging.
Collapse
|
20
|
Grayburn PA, Brickner ME, Rutherford JD. The clinical dilemma of anorectic drug use and valvular heart disease. Am J Cardiol 1999; 84:324-6, A8. [PMID: 10496444 DOI: 10.1016/s0002-9149(99)00285-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Recent attention has focused on reported valvular heart lesions in patients taking anorectic drugs. This editorial reviews published reports, comments on new findings from a study published in this issue of The American Journal of Cardiology, and makes clinical recommendations.
Collapse
|
21
|
Abstract
BACKGROUND The recent development of new fluorocarbon-based echocardiographic contrast agents that are capable of opacification of the left-sided cardiac chambers after intravenous injection is a major new advance in diagnostic cardiac imaging. METHODS AND RESULTS This is a review article focusing on these novel contrast agents, new echocardiographic imaging techniques to optimize their efficacy, and their clinical applications. Specific clinical applications of these agents are (1) enhancement of endocardial border definition to improve assessment of regional and global left ventricular function, (2) myocardial perfusion imaging by intravenous contrast echocardiography, (3) augmentation of spectral and color flow Doppler images, and (4) tissue-specific targeting of microbubbles for delivery of therapeutic agents. CONCLUSIONS New intravenous contrast agents offer the possibility to assess myocardial perfusion echocardiographically. It is also possible to use these agents for delivery of therapeutic agents, including gene therapy.
Collapse
|
22
|
Hundley WG, Kizilbash AM, Afridi I, Franco F, Peshock RM, Grayburn PA. Administration of an intravenous perfluorocarbon contrast agent improves echocardiographic determination of left ventricular volumes and ejection fraction: comparison with cine magnetic resonance imaging. J Am Coll Cardiol 1998; 32:1426-32. [PMID: 9809958 DOI: 10.1016/s0735-1097(98)00409-4] [Citation(s) in RCA: 145] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The purpose of this study was to determine whether contrast-enhanced transthoracic echocardiography improves the evaluation of left ventricular (LV) volumes and ejection fraction (EF). BACKGROUND Echocardiographic assessment of LV volumes and EF is widely used but may be inaccurate when the endocardium is not completely visualized. Recently the intravenous (i.v.) administration of perfluorocarbon microbubbles has been shown to enhance opacification of the LV cavity, but the utility of these agents to improve the echocardiographic assessment of LV systolic function is unknown. METHODS In 40 subjects (29 men and 11 women, aged 24 to 81 years) an assessment of LV volumes and EF was performed with a magnetic resonance imaging examination, followed immediately by a transthoracic echocardiogram before and after the intravenous administration of 2% dodecafluoropentane emulsion (EchoGen; Sonus Pharmaceuticals, Bothell, Washington). RESULTS Contrast enhanced the echocardiographic assessment of LV end diastolic volume (p < 0.02), end systolic volume (p < 0.01) and LVEF (p < 0.03). The percentage of subjects in whom the correct echocardiographic classification EF was normal, mild to moderately depressed or severely reduced improved significantly after contrast enhancement (from 71% before contrast to 94% after, p < 0.03). These findings were most striking in the subjects with two or more adjacent endocardial segments not visualized at baseline. CONCLUSIONS Administration of an intravenous contrast agent improves the ability to accurately assess LV volumes and EF in humans. Contrast enhancement is most useful in subjects with two or more adjacent endocardial segments not seen at baseline.
Collapse
|
23
|
Sayad DE, Willett DL, Hundley WG, Grayburn PA, Peshock RM. Dobutamine magnetic resonance imaging with myocardial tagging quantitatively predicts improvement in regional function after revascularization. Am J Cardiol 1998; 82:1149-51, A10. [PMID: 9817504 DOI: 10.1016/s0002-9149(98)00579-7] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Segmental contractile reserve measured by dobutamine magnetic resonance imaging quantitatively predicts improvement in end-systolic wall thickness after revascularization. Segments with end-systolic wall thickness <7 mm at rest do not demonstrate contractile reserve or improve after revascularization.
Collapse
|
24
|
Afridi I, Grayburn PA, Panza JA, Oh JK, Zoghbi WA, Marwick TH. Myocardial viability during dobutamine echocardiography predicts survival in patients with coronary artery disease and severe left ventricular systolic dysfunction. J Am Coll Cardiol 1998; 32:921-6. [PMID: 9768712 DOI: 10.1016/s0735-1097(98)00321-0] [Citation(s) in RCA: 199] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES The purpose of this study was to assess whether the presence or absence of myocardial viability during dobutamine echocardiography (DE) predicts survival in patients with coronary artery disease (CAD) and severe left ventricular (LV) dysfunction. BACKGROUND In patients with CAD, the presence of myocardial viability during DE identifies viable myocardium and predicts recovery of LV systolic function after revascularization. However, there is little data on the relation between myocardial viability and clinical outcome in patients with CAD and severe LV dysfunction. METHODS We studied 318 patients with CAD and a LV ejection fraction (EF) < or =35% who underwent DE and were followed for 18+/-10 months. Patients were classified into four groups. Group I (n=85) consisted of patients who had evidence of myocardial viability and subsequently underwent revascularization. Group II (n=119) consisted of patients with myocardial viability who did not undergo revascularization. Group III (n=30) consisted of patients who did not have myocardial viability and underwent revascularization. Finally, group IV (n=84) patients lacked myocardial viability and did not undergo revascularization. RESULTS The four groups had similar baseline characteristics and rest LVEF. During follow-up there were 51 deaths (16%). The mortality rate was 6% in group I, 20% in group II, 17% in group III and 20% in group TV (p=0.01, group I vs. other groups). CONCLUSIONS In patients with CAD and severe LV dysfunction who demonstrated myocardial viability during DE, revascularization improved survival compared with medical therapy.
Collapse
|
25
|
Afridi I, Main ML, Parrish DL, Kizilbash A, Levine BD, Grayburn PA. Usefulness of isometric hand grip exercise in detecting coronary artery disease during dobutamine atropine stress echocardiography in patients with either stable angina pectoris or another type of positive stress test. Am J Cardiol 1998; 82:564-8. [PMID: 9732880 DOI: 10.1016/s0002-9149(98)00398-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Dobutamine atropine stress echocardiography (DASE) detects coronary artery disease (CAD) by increasing myocardial oxygen demand causing ischemia. The sensitivity of the test for detection of CAD is reduced in patients with submaximal stress. We hypothesized that increasing cardiac work load by adding isometric exercise would improve the detection of ischemia during DASE. We studied 31 patients, mean age 57+/-11 years, with angiographically documented CAD. Patients underwent DASE using incremental dobutamine doses from 5 to 40 microg/kg/min, followed by atropine if peak heart rate was <85% of predicted maximal. Hand grip was then performed for 2 minutes at 33% of maximal voluntary contraction, while dobutamine infusion was maintained at the peak dose. The addition of hand grip during dobutamine stress was associated with a significant increase in systolic blood pressure (143+/-21 vs 164+/-24 mm Hg, p = 0.001) and left ventricular end-systolic circumferential wall stress (72+/-30 x 10(3) dynes/cm2 vs 132+/-34 x 10(3) dynes/cm2, p = 0.004). Wall motion score index increased from 1.0 at rest to 1.15+/-0.18 with dobutamine (p = 0.0004 vs rest), and increased further to 1.29+/-0.22 with the addition of hand grip (p = 0.004 vs dobutamine). Ischemia was detected in 19 patients (62%) with dobutamine-atropine stress alone and in 25 (83%) after the addition of hand grip (p <0.05). The addition of hand grip during DASE is feasible, and improves the detection of myocardial ischemia.
Collapse
|