1
|
Nguyen SA, Suranyi P, Ravenel JG, Randall PK, Romano PB, Strom KA, Costello P, Schoepf UJ. Iso-osmolality versus low-osmolality iodinated contrast medium at intravenous contrast-enhanced CT: effect on kidney function. Radiology 2008; 248:97-105. [PMID: 18483232 DOI: 10.1148/radiol.2481071484] [Citation(s) in RCA: 90] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
PURPOSE To determine the effects of iso-osmolality contrast medium compared with a low-osmolality agent on renal function (serum creatinine [SCr] and glomerular filtration rate [GFR]) in high-risk patients undergoing intravenous contrast material-enhanced CT. MATERIALS AND METHODS This HIPAA-compliant study was IRB-approved; formal consent was obtained. One hundred seventeen patients (83 men, 34 women; mean age, 64.3 years; range, 18-86 years) with decreased renal function underwent contrast-enhanced CT with either iso-osmolality iodixanol (n = 61) or low-osmolality iopromide (n = 56). Outcome measures were of SCr increase or GFR decrease for 3 days after CT, a SCr increase (of >or=0.5 mg/dL [44.2 micromol/L, 25%] or >or=1.0 mg/dL [88.4 micromol/L, 50%]), a GFR reduction (of >or=5 mL/min), and patient outcome at 30- and 90-day follow-up. RESULTS Iodixanol decreased SCr (mean +/- standard deviation) from 1.77 mg/dL +/- 0.24 (156.47 micromol/L +/- 21.22) at baseline to 1.65 mg/dL +/- 0.35 (145.86 micromol/L +/- 30.94, P = .046) at day 1, 1.73 mg/dL +/- 0.53 (152.93 micromol/L +/- 46.85, not significant) at day 2, and 1.73 mg/dL +/- 0.55 (152.93 micromol/L +/- 48.62, not significant) at day 3 (not significant). Iopromide increased SCr from 1.75 mg/dL +/- 0.32 (154.7 micromol/L +/- 28.29) at baseline to 1.8 mg/dL +/- 0.42 (159.12 micromol/L +/- 15.59) at day 1, 1.77 mg/dL +/- 0.49 (156.47 micromol/L +/- 43.32) at day 2, and 1.77 mg/dL +/- 0.62 (156.47 micromol/L +/- 54.81) at day 3 (not significant). Iodixanol increased and iopromide decreased GFR on all 3 days after CT (not significant). Fewer patients in the iodixanol group (8.5%) than in the iopromide group (27.8%) had SCr increase 0.5 mg/dL or higher (>or=25%, P = .012). Two patients in each group had SCr increase of 1.0 mg/dL or more (not significant). More patients in the iopromide group (42.3%) than in the iodoxanol group (24.1%) had a GFR reduction of 5 mL/min or higher (P = .0426). No patient had a contrast material-related adverse event at 30- or 90-day follow-up. CONCLUSION Intravenous contrast material application in high-risk patients is unlikely to be associated with permanent adverse outcomes. SCr levels after contrast material administration are lower in iodixanol than iopromide groups.
Collapse
|
Research Support, Non-U.S. Gov't |
17 |
90 |
2
|
|
|
61 |
85 |
3
|
Kerl JM, Ravenel JG, Nguyen SA, Suranyi P, Thilo C, Costello P, Bautz W, Schoepf UJ. Right Heart: Split-Bolus Injection of Diluted Contrast Medium for Visualization at Coronary CT Angiography. Radiology 2008; 247:356-64. [DOI: 10.1148/radiol.2472070856] [Citation(s) in RCA: 84] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
|
17 |
84 |
4
|
Blanke P, Russe M, Leipsic J, Reinöhl J, Ebersberger U, Suranyi P, Siepe M, Pache G, Langer M, Schoepf UJ. Conformational pulsatile changes of the aortic annulus: impact on prosthesis sizing by computed tomography for transcatheter aortic valve replacement. JACC Cardiovasc Interv 2013; 5:984-94. [PMID: 22995887 DOI: 10.1016/j.jcin.2012.05.014] [Citation(s) in RCA: 79] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2012] [Accepted: 05/12/2012] [Indexed: 10/27/2022]
Abstract
OBJECTIVES This study sought to investigate pulsatile changes of the aortic annulus and their impact on prosthesis selection by computed tomography (CT). BACKGROUND Precise noninvasive prosthesis sizing is a prerequisite for transcatheter aortic valve replacement. METHODS A total of 110 patients with severe aortic stenosis (mean age: 82.9 ± 8 years, mean aortic valve area: 0.69 ± 0.18 cm(2)) underwent electrocardiogram-gated CT. Aortic annulus dimensions were planimetrically quantified as area-derived diameter (D(A) = 2 ×✓(CSA/π), where CSA is the cross-sectional area) and perimeter-derived diameter (D(P) = P/π, where P is the length of the perimeter) in 5% increments of the RR interval. Hypothetical prosthesis sizing was based on D(A) and D(P) (23-mm prosthesis for <22 mm; 26 mm: 22 to 25 mm; 29 mm: >25 mm) and compared between maximum and traditional cardiac CT reconstruction phases at 35% and 75% of RR. Agreement for prosthesis selection was calculated by κ statistics. RESULTS D(A) and D(P) were increased and eccentricity was reduced during systole, with D(A-MAX) and D(P-MAX) most often observed at 20% of RR. D(P) was consistently larger than D(A). Average net differences were 2.0 ± 0.6 mm and 1.7 ± 0.5 mm by D(A-MIN) versus D(A-MAX) and D(P-MIN) versus D(P-MAX). Agreement for prosthesis sizing was found in 93 of 110 patients (κ = 0.75) by D(A-75%) and in 80 of 110 patients (κ = 0.53) by D(A-MAX) compared with D(A-35%); and in 94 of 110 patients (κ = 0.73) by D(P-75%) and in 93 of 110 patients (κ = 0.73) by D(P-MAX) compared with D(P-35%). With sizing by D(A-75%) or D(P-75%), nominal prosthesis diameter was smaller than D(A-MAX) or D(P-MAX) in 15 and 6 patients respectively. CONCLUSIONS Aortic annulus morphology exhibits conformational pulsatile changes throughout the cardiac cycle due to deformation and stretch. These changes affect prosthesis selection. Prosthesis selection by diastolic perimeter- or area-derived dimensions harbors the risk of undersizing.
Collapse
|
Journal Article |
12 |
79 |
5
|
Muscogiuri G, Rehwald WG, Schoepf UJ, Suranyi P, Litwin SE, De Cecco CN, Wichmann JL, Mangold S, Caruso D, Fuller SR, Bayer Nd RR, Varga-Szemes A. T(Rho) and magnetization transfer and INvErsion recovery (TRAMINER)-prepared imaging: A novel contrast-enhanced flow-independent dark-blood technique for the evaluation of myocardial late gadolinium enhancement in patients with myocardial infarction. J Magn Reson Imaging 2016; 45:1429-1437. [PMID: 27690324 DOI: 10.1002/jmri.25498] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2016] [Accepted: 09/14/2016] [Indexed: 11/11/2022] Open
Abstract
PURPOSE To evaluate a new dark-blood late gadolinium enhancement (LGE) technique called "T(Rho) And Magnetization transfer and INvErsion Recovery" (TRAMINER) for the ability to detect myocardial LGE versus standard "bright-blood" inversion recovery (SIR) imaging. MATERIALS AND METHODS This Institutional Review Board (IRB)-approved, Health Insurance Portability and Accountability Act (HIPAA)-compliant prospective study included 40 patients (62 ± 14 years [mean ± standard deviation (SD)], 29 males) with suspected myocardial infarction (MI) referred for the assessment of myocardial viability. The patients underwent a 1.5T cardiac magnetic resonance imaging (MRI) including postcontrast SIR and TRAMINER acquisitions. Normalized images were evaluated by two readers. Subjective (3-point Likert scale) and objective image qualities were compared using Mann-Whitney U-test and paired t-test, respectively. Interobserver agreement, LGE detection rate, and level of certainty were compared using Cohen's kappa, Wilcoxon-test, and Mann-Whitney U-test, respectively. Results are reported as mean ± SD or mean [95% confidence interval]. RESULTS Overall, image quality was rated similar between TRAMINER and SIR; however, TRAMINER performed better on a visual assessment of the ability to differentiate LGE from blood (Likert scale: 3.0 [3.0-3.0] vs. 2.0 [1.7-2.2], P < 0.0001). TRAMINER provided significantly higher signal intensity range (69.8 ± 10.2 vs. 9.6 ± 7.6, P < 0.0001) and a 4-fold higher signal intensity ratio (4.2 ± 1.9 vs. 1.1 ± 0.1, P < 0.0001) between LGE and blood signals. TRAMINER detected more patients (19/40 vs. 17/40) and segments (91/649 vs. 79/649) with LGE with higher level of certainty (2.9 [2.8-3.0] vs. 2.7 [2.5-2.8], P = 0.0185). Interobserver agreement was good to excellent for LGE detection. CONCLUSION TRAMINER provides better contrast between LGE and blood and consequently may have increased ability to discriminate thin subendocardial and papillary muscle enhancement from the blood signal, which can have an indistinct appearance using SIR. LEVEL OF EVIDENCE 2 J. MAGN. RESON. IMAGING 2017;45:1429-1437.
Collapse
|
Journal Article |
9 |
37 |
6
|
Aquino GJ, O'Doherty J, Schoepf UJ, Ellison B, Byrne J, Fink N, Zsarnoczay E, Wolf EV, Allmendinger T, Schmidt B, Flohr T, Baruah D, Suranyi P, Varga-Szemes A, Emrich T. Myocardial Characterization with Extracellular Volume Mapping with a First-Generation Photon-counting Detector CT with MRI Reference. Radiology 2023; 307:e222030. [PMID: 36719292 DOI: 10.1148/radiol.222030] [Citation(s) in RCA: 36] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Background Photon-counting detector (PCD) CT provides comprehensive spectral data with every acquisition, but studies evaluating myocardial extracellular volume (ECV) quantification with use of PCD CT compared with an MRI reference remain lacking. Purpose To compare ECV quantification for myocardial tissue characterization between a first-generation PCD CT system and cardiac MRI. Materials and Methods In this single-center prospective study, adults without contraindication to iodine-based contrast media underwent same-day cardiac PCD CT and MRI with native and postcontrast T1 mapping and late gadolinium enhancement for various clinical indications for cardiac MRI (the reference standard) between July 2021 and January 2022. Global and midventricular ECV were assessed with use of three methods: single-energy PCD CT, dual-energy PCD CT, and MRI T1 mapping. Quantitative comparisons among all techniques were performed. Correlation and reliability between different methods of ECV quantification were assessed with use of the Pearson correlation coefficient (r) and the intraclass correlation coefficient. Results The final sample included 29 study participants (mean age ± SD, 54 years ± 17; 15 men). There was a strong correlation of ECV between dual- and single-energy PCD CT (r = 0.91, P < .001). Radiation dose was 40% lower with dual-energy versus single-energy PCD CT (volume CT dose index, 10.1 mGy vs 16.8 mGy, respectively; P < .001). In comparison with MRI, dual-energy PCD CT showed strong correlation (r = 0.82 and 0.91, both P < .001) and good to excellent reliability (intraclass correlation coefficients, 0.81 and 0.90) for midventricular and global ECV quantification, but it overestimated ECV by approximately 2%. Single-energy PCD CT showed similar relationship with MRI but underestimated ECV by 3%. Conclusion Myocardial tissue characterization with photon-counting detector CT-based quantitative extracellular volume analysis showed a strong correlation to MRI. © RSNA, 2023 Supplemental material is available for this article.
Collapse
|
|
2 |
36 |
7
|
Bresser W, Boolchand P, Suranyi P. Rigidity percolation and molecular clustering in network glasses. PHYSICAL REVIEW LETTERS 1986; 56:2493-2496. [PMID: 10033007 DOI: 10.1103/physrevlett.56.2493] [Citation(s) in RCA: 28] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
|
|
39 |
28 |
8
|
Karasik D, Sahabandu C, Suranyi P, Wijewardhana L. Analytic approximation to 5 dimensional black holes with one compact dimension. Int J Clin Exp Med 2005. [DOI: 10.1103/physrevd.71.024024] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
|
20 |
27 |
9
|
Varga-Szemes A, Muscogiuri G, Schoepf UJ, Wichmann JL, Suranyi P, De Cecco CN, Cannaò PM, Renker M, Mangold S, Fox MA, Ruzsics B. Clinical feasibility of a myocardial signal intensity threshold-based semi-automated cardiac magnetic resonance segmentation method. Eur Radiol 2015; 26:1503-11. [PMID: 26267520 DOI: 10.1007/s00330-015-3952-4] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2015] [Revised: 07/15/2015] [Accepted: 07/28/2015] [Indexed: 11/29/2022]
Abstract
OBJECTIVES To assess the accuracy and efficiency of a threshold-based, semi-automated cardiac MRI segmentation algorithm in comparison with conventional contour-based segmentation and aortic flow measurements. METHODS Short-axis cine images of 148 patients (55 ± 18 years, 81 men) were used to evaluate left ventricular (LV) volumes and mass (LVM) using conventional and threshold-based segmentations. Phase-contrast images were used to independently measure stroke volume (SV). LV parameters were evaluated by two independent readers. RESULTS Evaluation times using the conventional and threshold-based methods were 8.4 ± 1.9 and 4.2 ± 1.3 min, respectively (P < 0.0001). LV parameters measured by the conventional and threshold-based methods, respectively, were end-diastolic volume (EDV) 146 ± 59 and 134 ± 53 ml; end-systolic volume (ESV) 64 ± 47 and 59 ± 46 ml; SV 82 ± 29 and 74 ± 28 ml (flow-based 74 ± 30 ml); ejection fraction (EF) 59 ± 16 and 58 ± 17%; and LVM 141 ± 55 and 159 ± 58 g. Significant differences between the conventional and threshold-based methods were observed in EDV, ESV, and LVM mesurements; SV from threshold-based and flow-based measurements were in agreement (P > 0.05) but were significantly different from conventional analysis (P < 0.05). Excellent inter-observer agreement was observed. CONCLUSIONS Threshold-based LV segmentation provides improved accuracy and faster assessment compared to conventional contour-based methods. KEY POINTS • Threshold-based left ventricular segmentation provides time-efficient assessment of left ventricular parameters • The threshold-based method can discriminate between blood and papillary muscles • This method provides improved accuracy compared to aortic flow measurements as a reference.
Collapse
|
Journal Article |
10 |
26 |
10
|
Juhasz F, Boros P, Szegedi G, Balazs G, Suranyi P, Kraszits E, Stenszky V, Farid NR. Immunogenetic and immunologic studies of differentiated thyroid cancer. Cancer 1989; 63:1318-26. [PMID: 2784072 DOI: 10.1002/1097-0142(19890401)63:7<1318::aid-cncr2820630716>3.0.co;2-r] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
The authors have studied in detail human leukocyte antigen (HLA) association in 87 Hungarian patients with thyroid epithelial carcinoma. The authors also examined in a small group of patients, five parameters of cell-mediated immunity and related them to HLA as well as to lymphocytic infiltration of the tumor/normal tissue interface. HLA-DR1 was significantly associated with thyroid carcinoma; the strongest association was in patients with follicular histologic features and DR1 homozygotes were not at greater risk for thyroid cancer. The HLA-DR3 was nonsignificantly increased in patients with papillary or mixed histologic features. The HLA-DR1, 3 heterozygotes were highly associated with follicular carcinoma, carried no risk for papillary carcinoma, and an intermediate risk for tumors with mixed histologic features. Because of the small proportion of DR1, 3 heterozygotes in the follicular and mixed histologic group, its predictive value at the population level was low. Better predictive potential was shown for the phenotype DR1 and/or DR3. Neither metastatic disease nor age at diagnosis (less than 45 years) could be related to HLA phenotypes. Patients in all histologic variants showed some measure of cell-mediated immunity compared to controls. Patients with papillary carcinoma showed an overall better response than those with tumors with follicular or mixed histology. The HLA-DR could not be related to cell-mediated immune response. Patients with papillary carcinoma with a good cell-mediated immune response occurred with much lower infiltration of the tumor boundary with lymphocyte whereas the follicular carcinoma less cell-mediated immunity was associated with dense lymphocytic infiltration, suggesting the biological relevance of lymphocytic infiltration may be different for the two histologic variants.
Collapse
|
|
36 |
21 |
11
|
Karasik D, Sahabandu C, Suranyi P, Wijewardhana LCR. Small brane black holes in the Randall-Sundrum type I scenario. Int J Clin Exp Med 2004. [DOI: 10.1103/physrevd.69.064022] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
|
21 |
21 |
12
|
Varga-Szemes A, van der Geest RJ, Spottiswoode BS, Suranyi P, Ruzsics B, De Cecco CN, Muscogiuri G, Cannaò PM, Fox MA, Wichmann JL, Vliegenthart R, Schoepf UJ. Myocardial Late Gadolinium Enhancement: Accuracy of T1 Mapping-based Synthetic Inversion-Recovery Imaging. Radiology 2015; 278:374-82. [PMID: 26230908 DOI: 10.1148/radiol.2015150162] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
PURPOSE To compare the accuracy of detection and quantification of myocardial late gadolinium enhancement (LGE) with a synthetic inversion-recovery (IR) approach with that of conventional IR techniques. MATERIALS AND METHODS This prospective study was approved by the institutional review board and compliant with HIPAA. All patients gave written informed consent. Between June and November 2014, 43 patients (25 men; mean age, 54 years ± 16) suspected of having previous myocardial infarction underwent magnetic resonance (MR) imaging, including contrast material-enhanced LGE imaging and T1 mapping. Synthetic magnitude and phase-sensitive IR images were generated on the basis of T1 maps. Images were assessed by two readers. Differences in the per-patient and per-segment LGE detection rates between the synthetic and conventional techniques were analyzed with the McNemar test, and the accuracy of LGE quantification was calculated with the paired t test and Bland-Altman statistics. Interreader agreement for the detection and quantification of LGE was analyzed with κ and Bland-Altman statistics, respectively. RESULTS Seventeen of the 43 patients (39%) had LGE patterns consistent with myocardial infarction. The sensitivity and specificity of synthetic magnitude and phase-sensitive IR techniques in the detection of LGE were 90% and 95%, respectively, with patient-based analysis and 94% and 99%, respectively, with segment-based analysis. The area of LGE measured with synthetic IR techniques showed excellent agreement with that of conventional techniques (4.35 cm(2) ± 1.88 and 4.14 cm(2)± 1.62 for synthetic magnitude and phase-sensitive IR, respectively, compared with 4.25 cm(2) ± 1.92 and 4.22 cm(2) ± 1.86 for conventional magnitude and phase-sensitive IR, respectively; P > .05). Interreader agreement was excellent for the detection (κ > 0.81) and quantification (bias range, -0.34 to 0.40; P > .05) of LGE. CONCLUSION The accuracy of the T1 map-based synthetic IR approach in the detection and quantification of myocardial LGE in patients with previous myocardial infarction was similar to that of conventional IR techniques. The use of T1 mapping to derive synthetic LGE images may reduce imaging times and operator dependence in future T1 mapping protocols with full left ventricular coverage.
Collapse
|
Journal Article |
10 |
19 |
13
|
|
|
39 |
17 |
14
|
Gray JC, Krazinski AW, Schoepf UJ, Meinel FG, Pietris NP, Suranyi P, Hlavacek AM. Cardiovascular manifestations of Williams syndrome: imaging findings. J Cardiovasc Comput Tomogr 2013; 7:400-7. [PMID: 24331936 DOI: 10.1016/j.jcct.2013.11.007] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/01/2013] [Revised: 10/21/2013] [Accepted: 11/04/2013] [Indexed: 12/01/2022]
Abstract
Williams syndrome is a relatively common (1 in 10,000 live births) genetic disorder caused by a deletion involving chromosome 7 that results in a variety of clinically significant abnormalities, including developmental delay, behavioral changes, hypercalcemia, and a distinct "elfin" facial appearance. Congenital cardiovascular disease that presents in childhood is responsible for most of the morbidity and mortality associated with this disorder. The purpose of this pictorial essay is to review imaging findings of some of the more common cardiovascular manifestations of Williams syndrome and to highlight some of the unique anatomic variations that can be seen in these patients.
Collapse
|
Review |
12 |
15 |
15
|
Varga-Szemes A, Penmetsa M, Emrich T, Todoran TM, Suranyi P, Fuller SR, Edelman RR, Koktzoglou I, Schoepf UJ. Diagnostic accuracy of non-contrast quiescent-interval slice-selective (QISS) MRA combined with MRI-based vascular calcification visualization for the assessment of arterial stenosis in patients with lower extremity peripheral artery disease. Eur Radiol 2020; 31:2778-2787. [PMID: 33068186 DOI: 10.1007/s00330-020-07386-4] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Revised: 06/04/2020] [Accepted: 10/07/2020] [Indexed: 10/23/2022]
Abstract
OBJECTIVES The proton density-weighted, in-phase stack-of-stars (PDIP-SOS) MRI technique provides calcification visualization in peripheral artery disease (PAD). This study sought to investigate the diagnostic accuracy of a combined non-contrast quiescent-interval slice-selective (QISS) MRA and PDIP-SOS MRI protocol for the detection of PAD, in comparison with CTA and digital subtraction angiography (DSA). METHODS Twenty-six prospectively enrolled PAD patients (70 ± 8 years) underwent lower extremity CTA and 1.5-T or 3-T PDIP-SOS/QISS MRI prior to DSA. Two readers rated image quality and graded stenosis (≥ 50%) on QISS MRA without/with calcification visualization. Sensitivity, specificity, and area under the curve (AUC) were calculated against DSA. Calcification was quantified and compared between MRI and non-contrast CT (NCCT) using paired t test, Pearson's correlation, and Bland-Altman analysis. RESULTS Image quality ratings were significantly higher for CTA compared to those for MRA (4.0 [3.0-4.0] and 3.0 [3.0-4.0]; p = 0.0369). The sensitivity and specificity of QISS MRA, QISS MRA with PDIP-SOS, and CTA for ≥ 50% stenosis detection were 85.4%, 92.2%, and 90.2%, and 90.3%, 93.2%, and 94.2%, respectively, while AUCs were 0.879, 0.928, and 0.923, respectively. A significant increase in AUC was observed when PDIP-SOS was added to the MRA protocol (p = 0.0266). Quantification of calcification showed significant differences between PDIP-SOS and NCCT (80.6 ± 31.2 mm3 vs. 88.0 ± 29.8 mm3; p = 0.0002) with high correlation (r = 0.77, p < 0.0001) and moderate mean of differences (- 7.4 mm3). CONCLUSION QISS MRA combined with PDIP-SOS MRI provides improved, CTA equivalent, accuracy for the detection of PAD, although its image quality remains inferior to CTA. KEY POINTS • Agreement in stenosis detection rate using non-contrast quiescent-interval slice-selective MRA compared to DSA improved when calcification visualization was provided to the readers. • An increase was observed in both sensitivity and specificity for the detection of ≥ 50% stenosis when MRI-based calcification assessment was added to the protocol, resulting in a diagnostic accuracy more comparable to CTA. • Quantification of calcification showed statistical difference between MRI and non-contrast CT; however, a high correlation was observed between the techniques.
Collapse
|
Journal Article |
5 |
12 |
16
|
Kirschner R, Toth L, Varga-Szemes A, Simor T, Suranyi P, Kiss P, Ruzsics B, Toth A, Baker R, Brott BC, Litovsky S, Elgavish A, Elgavish GA. Differentiation of acute and four-week old myocardial infarct with Gd(ABE-DTTA)-enhanced CMR. J Cardiovasc Magn Reson 2010; 12:22. [PMID: 20377842 PMCID: PMC2867985 DOI: 10.1186/1532-429x-12-22] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2009] [Accepted: 04/07/2010] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND Standard extracellular cardiovascular magnetic resonance (CMR) contrast agents (CA) do not provide differentiation between acute and older myocardial infarcts (MI). The purpose of this study was to develop a method for differentiation between acute and older myocardial infarct using myocardial late-enhancement (LE) CMR by a new, low molecular weight contrast agent.Dogs (n = 6) were studied in a closed-chest, reperfused, double myocardial infarct model. Myocardial infarcts were generated by occluding the Left Anterior Descending (LAD) coronary artery with an angioplasty balloon for 180 min, and four weeks later occluding the Left Circumflex (LCx) coronary artery for 180 min. LE images were obtained on day 3 and day 4 after second myocardial infarct, using Gd(DTPA) (standard extracellular contrast agent) and Gd(ABE-DTTA) (new, low molecular weight contrast agent), respectively. Triphenyltetrazolium chloride (TTC) histomorphometry validated existence and location of infarcts. Hematoxylin-eosin and Masson's trichrome staining provided histologic evaluation of infarcts. RESULTS Gd(ABE-DTTA) or Gd(DTPA) highlighted the acute infarct, whereas the four-week old infarct was visualized by Gd(DTPA), but not by Gd(ABE-DTTA). With Gd(ABE-DTTA), the mean +/- SD signal intensity enhancement (SIE) was 366 +/- 166% and 24 +/- 59% in the acute infarct and the four-week old infarct, respectively (P < 0.05). The latter did not differ significantly from signal intensity in healthy myocardium (P = NS). Gd(DTPA) produced signal intensity enhancements which were similar in acute (431 +/- 124%) and four-week old infarcts (400 +/- 124%, P = NS), and not statistically different from the Gd(ABE-DTTA)-induced SIE in acute infarct. The existence and localization of both infarcts were confirmed by triphenyltetrazolium chloride (TTC). Histologic evaluation demonstrated coagulation necrosis, inflammation, and multiple foci of calcification in the four day old infarct, while the late subacute infarct showed granulation tissue and early collagen deposition. CONCLUSIONS Late enhancement CMR with separate administrations of standard extracellular contrast agent, Gd(DTPA), and the new low molecular weight contrast agent, Gd(ABE-DTTA), differentiates between acute and late subacute infarct in a reperfused, double infarct, canine model.
Collapse
|
Comparative Study |
15 |
11 |
17
|
Muscogiuri G, Suranyi P, Eid M, Varga-Szemes A, Griffith L, Pontone G, Schoepf UJ, De Cecco CN. Pediatric Cardiac MR Imaging:: Practical Preoperative Assessment. Magn Reson Imaging Clin N Am 2019; 27:243-262. [PMID: 30910096 DOI: 10.1016/j.mric.2019.01.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Prevalence of patients with congenital heart disease (CHD) is rapidly increasing due to continuous advancements in diagnostic techniques and medical or surgical treatment approaches. Along with cardiac computed tomography angiography, cardiac magnetic resonance (CMR) serves as a fundamental imaging modality for pre-surgical planning in patients with CHD, as CMR allows for the evaluation of cardiac and great vessel anatomy, biventricular function, flow dynamics, and tissue characterization. This information is essential for risk-assessment and optimal timing of surgical interventions. This article discusses the current role of pediatric cardiac MR imaging as a practical preoperative assessment tool in the pediatric population.
Collapse
|
Review |
6 |
11 |
18
|
Pinos D, Griffith J, Emrich T, Schoepf UJ, O'Doherty J, Zsarnoczay E, Fink N, Vecsey-Nagy M, Suranyi P, Tesche C, Aquino GJ, Varga-Szemes A, Brandt V. Intra-individual comparison of image quality of the coronary arteries between photon-counting detector and energy-integrating detector CT systems. Eur J Radiol 2023; 166:111008. [PMID: 37542817 DOI: 10.1016/j.ejrad.2023.111008] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Accepted: 07/23/2023] [Indexed: 08/07/2023]
Abstract
PURPOSE To intra-individually compare the objective and subjective image quality of coronary computed tomography angiography (CCTA) between photon-counting detector CT (PCD-CT) and energy-integrating detector CT (EID-CT). METHOD Consecutive patients undergoing clinically indicated CCTA on an EID-CT system were prospectively enrolled for a research CCTA performed on a PCD-CT system within 30 days. Polychromatic images were reconstructed for both EID- and PCD-CT, while virtual monoenergetic images (VMI) were generated at 40, 45, 50, 55, 60 and 70 keV for PCD-CT. Two blinded readers calculated contrast-to-noise ratio (CNR) for each major coronary artery and rated image noise, vessel attenuation, vessel sharpness, and overall quality on a 1-5 Likert scale. Patients were then stratified by body mass index (BMI) [high (>30 kg/m2) vs low (<30 kg/m2)] for subgroup analysis. RESULTS A total of 20 patients (67.5 ± 9.0 years, 75% male) were included in the study. Compared with EID-CT, coronary artery CNR values from PCD-CT monoenergetic and polychromatic reconstructions were all significantly higher than CNR values from EID-CT, with incrementally greater differences in obese subjects (all p < 0.008). Subjective image noise and sharpness were also significantly higher for all VMI reconstructions compared to EID-CT (all p < 0.008). All subjective scores were significantly higher for 55, 60, and 70 keV PCD-CT than EID-CT values (all p < 0.05). CONCLUSIONS The improved objective and subjective image quality of PCD-CT compared to EID-CT may provide better visualization of the coronary arteries for a wide array of patients, especially those with a high BMI.
Collapse
|
|
2 |
11 |
19
|
Wolf EV, Müller L, Schoepf UJ, Fink N, Griffith JP, Zsarnoczay E, Baruah D, Suranyi P, Kabakus IM, Halfmann MC, Emrich T, Varga-Szemes A, O'Doherty J. Photon-counting detector CT-based virtual monoenergetic reconstructions: repeatability and reproducibility of radiomics features of an organic phantom and human myocardium. Eur Radiol Exp 2023; 7:59. [PMID: 37875769 PMCID: PMC10597903 DOI: 10.1186/s41747-023-00371-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2023] [Accepted: 07/17/2023] [Indexed: 10/26/2023] Open
Abstract
BACKGROUND Photon-counting detector computed tomography (PCD-CT) may influence imaging characteristics for various clinical conditions due to higher signal and contrast-to-noise ratio in virtual monoenergetic images (VMI). Radiomics analysis relies on quantification of image characteristics. We evaluated the impact of different VMI reconstructions on radiomic features in in vitro and in vivo PCD-CT datasets. METHODS An organic phantom consisting of twelve samples (four oranges, four onions, and four apples) was scanned five times. Twenty-three patients who had undergone coronary computed tomography angiography on a first generation PCD-CT system with the same image acquisitions were analyzed. VMIs were reconstructed at 6 keV levels (40, 55, 70, 90, 120, and 190 keV). The phantoms and the patients' left ventricular myocardium (LVM) were segmented for all reconstructions. Ninety-three original radiomic features were extracted. Repeatability and reproducibility were evaluated through intraclass correlations coefficient (ICC) and post hoc paired samples ANOVA t test. RESULTS There was excellent repeatability for radiomic features in phantom scans (all ICC = 1.00). Among all VMIs, 36/93 radiomic features (38.7%) in apples, 28/93 (30.1%) in oranges, and 33/93 (35.5%) in onions were not significantly different. For LVM, the percentage of stable features was high between VMIs ≥ 90 keV (90 versus 120 keV, 77.4%; 90 versus 190 keV, 83.9%; 120 versus 190 keV, 89.3%), while comparison to lower VMI levels led to fewer reproducible features (40 versus 55 keV, 8.6%). CONCLUSIONS VMI levels influence the stability of radiomic features in an organic phantom and patients' LVM; stability decreases considerably below 90 keV. RELEVANCE STATEMENT Spectral reconstructions significantly influence radiomic features in vitro and in vivo, necessitating standardization and careful attention to these reconstruction parameters before clinical implementation. KEY POINTS • Radiomic features have an excellent repeatability within the same PCD-CT acquisition and reconstruction. • Differences in VMI lead to decreased reproducibility for radiomic features. • VMI ≥ 90 keV increased the reproducibility of the radiomic features.
Collapse
|
research-article |
2 |
10 |
20
|
Bodolay E, Suranyi P, Juhasz F, Stenszky V, Balazs C, Farid NR. Methimazole blocks Graves' IgG but not interferon-gamma HLA-DR expression by thyroid cells. Immunol Lett 1988; 18:167-71. [PMID: 3139552 DOI: 10.1016/0165-2478(88)90015-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
We have expanded our early observation that a potent Graves' IgG preparation induces HLA-DR expression on thyroid cells, by showing that four randomly-selected Graves' IgG's were also capable of inducing DR antigens on thyroid cells. The effect of Graves' IgG was specific to thyroid cells, as it did not induce MHC Class II molecule expression on endothelial cells whereas interferon-gamma and immune complexes did so. The anti-thyroid drug methimazole was capable of rapidly reducing Graves' IgG-induced DR expression but to a much lesser extent than brought about by interferon-gamma. We conclude that Graves' IgG propagates thyroid-specific autoaggression by continued induction of DR antigens and than an important means whereby methimazole brings about remission is by reducing this induction.
Collapse
|
|
37 |
9 |
21
|
Wolf EV, Halfmann MC, Schoepf UJ, Zsarnoczay E, Fink N, Griffith JP, Aquino GJ, Willemink MJ, O’Doherty J, Hell MM, Suranyi P, Kabakus IM, Baruah D, Varga-Szemes A, Emrich T. Intra-individual comparison of coronary calcium scoring between photon counting detector- and energy integrating detector-CT: Effects on risk reclassification. Front Cardiovasc Med 2023; 9:1053398. [PMID: 36741832 PMCID: PMC9892711 DOI: 10.3389/fcvm.2022.1053398] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2022] [Accepted: 12/28/2022] [Indexed: 01/20/2023] Open
Abstract
Purpose To compare coronary artery calcium volume and score (CACS) between photon-counting detector (PCD) and conventional energy integrating detector (EID) computed tomography (CT) in a phantom and prospective patient study. Methods A commercially available CACS phantom was scanned with a standard CACS protocol (120 kVp, slice thickness/increment 3/1.5 mm, and a quantitative Qr36 kernel), with filtered back projection on the EID-CT, and with monoenergetic reconstruction at 70 keV and quantum iterative reconstruction off on the PCD-CT. The same settings were used to prospectively acquire data in patients (n = 23, 65 ± 12.1 years), who underwent PCD- and EID-CT scans with a median of 5.5 (3.0-12.5) days between the two scans in the period from August 2021 to March 2022. CACS was quantified using a commercially available software solution. A regression formula was obtained from the aforementioned comparison and applied to simulate risk reclassification in a pre-existing cohort of 514 patients who underwent a cardiac EID-CT between January and December 2021. Results Based on the phantom experiment, CACS PCD-CT showed a more accurate measurement of the reference CAC volumes (overestimation of physical volumes: PCD-CT 66.1 ± 1.6% vs. EID-CT: 77.2 ± 0.5%). CACS EID-CT and CACS PCD-CT were strongly correlated, however, the latter measured significantly lower values in the phantom (CACS PCD-CT : 60.5 (30.2-170.3) vs CACS EID-CT 74.7 (34.6-180.8), p = 0.0015, r = 0.99, mean bias -9.7, Limits of Agreement (LoA) -36.6/17.3) and in patients (non-significant) (CACS PCD-CT : 174.3 (11.1-872.7) vs CACS EID-CT 218.2 (18.5-876.4), p = 0.10, r = 0.94, mean bias -41.1, LoA -315.3/232.5). The systematic lower measurements of Agatston score on PCD-CT system led to reclassification of 5.25% of our simulated patient cohort to a lower classification class. Conclusion CACS PCD-CT is feasible and correlates strongly with CACS EID-CT , however, leads to lower CACS values. PCD-CT may provide results that are more accurate for CACS than EID-CT.
Collapse
|
research-article |
2 |
9 |
22
|
Bodolay E, Szegedi G, Suranyi P, Juhasz F, Stenszky V, Balazs C, Farid NR. Expression of HLA-DR antigens by thyroid cells: the effect of Graves' IgG. Immunol Lett 1987; 15:77-81. [PMID: 3111991 DOI: 10.1016/0165-2478(87)90080-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
We have investigated factors which influence HLA-DR expression on thyroid cells. While bTSH (100 mU/ml) did not enhance HLA-DR expression, it increased when brought about by IFN-gamma. Graves' IgG showed a dose-dependent (0.1-2 mg/ml) increase in DR expression and at a concentration of 2 mg/ml prolonged the time for which DR was expressed. The pathway of DR induction by Graves' IgG apparently differs from that by IFN-gamma. The humoral response in Graves' disease, by inducing DR expression, may be instrumental in propagating thyroid specific autoimmunity.
Collapse
|
|
38 |
9 |
23
|
Wince WB, Suranyi P, Schoepf UJ. Contemporary cardiovascular imaging methods for the assessment of at-risk myocardium. J Am Heart Assoc 2013; 3:e000473. [PMID: 24366853 PMCID: PMC3959708 DOI: 10.1161/jaha.113.000473] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
Review |
12 |
8 |
24
|
Stroud RE, Piccini D, Schoepf UJ, Heerfordt J, Yerly J, Di Sopra L, Rollins JD, Fischer AM, Suranyi P, Varga-Szemes A. Correcting versus resolving respiratory motion in free-breathing whole-heart MRA: a comparison in patients with thoracic aortic disease. Eur Radiol Exp 2019; 3:29. [PMID: 31363865 PMCID: PMC6667582 DOI: 10.1186/s41747-019-0107-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2019] [Accepted: 07/02/2019] [Indexed: 11/28/2022] Open
Abstract
Background Whole-heart magnetic resonance angiography (MRA) requires sophisticated methods accounting for respiratory motion. Our purpose was to evaluate the image quality of compressed sensing-based respiratory motion-resolved three-dimensional (3D) whole-heart MRA compared with self-navigated motion-corrected whole-heart MRA in patients with known thoracic aorta dilation. Methods Twenty-five patients were prospectively enrolled in this ethically approved study. Whole-heart 1.5-T MRA was acquired using a prototype 3D radial steady-state free-precession free-breathing sequence. The same data were reconstructed with a one-dimensional motion-correction algorithm (1D-MCA) and an extradimensional golden-angle radial sparse parallel reconstruction (XD-GRASP). Subjective image quality was scored and objective image quality was quantified (signal intensity ratio, SIR; vessel sharpness). Wilcoxon, McNemar, and paired t tests were used. Results Subjective image quality was significantly higher using XD-GRASP compared to 1D-MCA (median 4.5, interquartile range 4.5–5.0 versus 4.0 [2.25–4.75]; p < 0.001), as well as signal homogeneity (3.0 [3.0–3.0] versus 2.0 [2.0–3.0]; p = 0.003), and image sharpness (3.0 [2.0–3.0] vs 2.0 [1.25–3.0]; p < 0.001). SIR with the 1D-MCA and XD-GRASP was 6.1 ± 3.9 versus 7.4 ± 2.5, respectively (p < 0.001); while signal homogeneity was 274.2 ± 265.0 versus 199.8 ± 67.2 (p = 0.129). XD-GRASP provided a higher vessel sharpness (45.3 ± 10.7 versus 40.6 ± 101, p = 0.025). Conclusions XD-GRASP-based motion-resolved reconstruction of free-breathing 3D whole-heart MRA datasets provides improved image contrast, sharpness, and signal homogeneity and seems to be a promising technique that overcomes some of the limitations of motion correction or respiratory navigator gating.
Collapse
|
Research Support, Non-U.S. Gov't |
6 |
7 |
25
|
Suranyi P, Szegedi G, Damjanovich S, Juhasz F, Stenszky V, Farid NR. B lymphocyte subsets in Hashimoto's thyroiditis. Immunol Lett 1989; 22:147-50. [PMID: 2476382 DOI: 10.1016/0165-2478(89)90181-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Two B lymphocyte subsets are identified on the basis of possession or lack of a surface molecule, CD5. The CD5+ B lymphocytes synthesize autoantibodies and in the process rearrange proximal variables of immunoglobulin genes. We have here studied the proportion and absolute counts of CD5+ B lymphocytes in the peripheral blood of 31 patients with Hashimoto's thyroiditis and related the findings to their HLA phenotypes and clinical features. Although the percentage and absolute number of surface immunoglobulin-positive (B) lymphocytes was comparable in patients to those in twenty controls, % CD5+ was significantly higher in the patient group (38.1 +/- 11.6 [+/- S.D.] vs. 27.9 +/- 10.1, p = 0.009). The absolute CD5+ cells (microliters) were also higher in patients with Hashimoto's thyroiditis (77.90 +/- 37.50 vs. 55.1 +/- 29.8, p = 0.020). The proportion of CD5+ cells was even higher in HLA-DR3 positive patients (43.1% +/- 7.2, n = 13) compared to six DR3+ controls (26.17% +/- 9.7, p = 0.0005). The difference between DR3- patients and controls was not significant (28.6% +/- 10.5 vs. 34.4% +/- 13.0). As the CD5 molecule may be induced on activated B lymphocytes, this study suggests that Hashimoto's thyroiditis is associated with an increase of activated B lymphocytes engaged in autoantibody synthesis. This defect is particularly obvious in DR3+ patients.
Collapse
|
|
36 |
7 |