Optimization of CT pulmonary angiography for pulmonary embolism using task-based image quality assessment and diagnostic reference levels: A multicentric study. Phys Med 2024; 121:103365. [PMID: 38663347 DOI: 10.1016/j.ejmp.2024.103365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 02/12/2024] [Accepted: 04/19/2024] [Indexed: 05/12/2024] Open
Abstract
PURPOSE To establish size-specific diagnostic reference levels (DRLs) for pulmonary embolism (PE) based on patient CT examinations performed on 74 CT devices. To assess task-based image quality (IQ) for each device and to investigate the variability of dose and IQ across different CTs. To propose a dose/IQ optimization. METHODS 1051 CT pulmonary angiography dose data were collected. DRLs were calculated as the 75th percentile of CT dose index (CTDI) for two patient categories based on the thoracic perimeters. IQ was assessed with two thoracic phantom sizes using local acquisition parameters and three other dose levels. The area under the ROC curve (AUC) of a 2 mm low perfused vessel was assessed with a non-prewhitening with eye-filter model observer. The optimal IQ-dose point was mathematically assessed from the relationship between IQ and dose. RESULTS The DRLs of CTDIvol were 6.4 mGy and 10 mGy for the two patient categories. 75th percentiles of phantom CTDIvol were 6.3 mGy and 10 mGy for the two phantom sizes with inter-quartile AUC values of 0.047 and 0.066, respectively. After the optimization, 75th percentiles of phantom CTDIvol decreased to 5.9 mGy and 7.55 mGy and the interquartile AUC values were reduced to 0.025 and 0.057 for the two phantom sizes. CONCLUSION DRLs for PE were proposed as a function of patient thoracic perimeters. This study highlights the variability in terms of dose and IQ. An optimization process can be started individually and lead to a harmonization of practice throughout multiple CT sites.
Collapse
|
2
|
Assessment of temporal resolution and detectability of moving objects in CT: A task-based image quality study. Phys Med 2024; 120:103337. [PMID: 38552274 DOI: 10.1016/j.ejmp.2024.103337] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 03/12/2024] [Accepted: 03/25/2024] [Indexed: 04/19/2024] Open
Abstract
The metrics used for assessing image quality in computed tomography (CT) do not integrate the influence of temporal resolution. A shortcoming in the assessment of image quality for imaging protocols where motion blur can therefore occur. We developed a method to calculate the temporal resolution of standard CT protocols and introduced a specific spatiotemporal formulation of the non-prewhitening with eye filter (NPWE) model observer to assess the detectability of moving objects as a function of their speed. We scanned a cubic water phantom with a plexiglass cylindrical insert (120 HU) using a large panel of acquisition parameters (rotation times, pitch factors and collimation widths) on two systems (GE Revolution Apex and Siemens SOMATOM Force) to determine the in-plane task-based transfer functions (TTF) and noise power spectra (NPS). The phantom set in a uniform rectilinear motion in the transverse plane allowed the temporal modulation transfer function (MTF) calculation. The temporal MTF appropriately compared the temporal resolution of the various acquisition protocols. The longitudinal TTF was measured using a thin tungsten wire. The detectability index showed the advantage of applying high rotation speed, wide collimations and high pitch for object detection in the presence of motion. No counterpart to the increase in these three parameters was found in the in-plane and longitudinal image quality.
Collapse
|
3
|
Proposed DRLs for Mammography in Switzerland. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2024. [PMID: 38530290 DOI: 10.1088/1361-6498/ad37c8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/27/2024]
Abstract
OBJECTIVES
The aim of this study is to propose Diagnostic Reference Levels (DRLs) values for mammography in Switzerland.
Methods:
For the data collection, a survey was conducted among a sufficient number of centres, including 5 University hospitals, several cantonal hospitals, and large private clinics, covering all linguistic regions of Switzerland to be representative of the clinical practice. The data gathered contained the mean glandular dose (MGD), the compressed breast thickness (CBT), the mammography model and the examination parameters for each acquisition. The data collected was sorted into the following categories: 2D or digital breast tomosynthesis (DBT) examination, craniocaudal (CC) or mediolateral oblique (MLO) projection, and 8 categories of compressed breast thickness (CBT) ranging from 20mm to 100mm in 10mm intervals.
Results:
24762 acquisitions acquired in 31 centres on 36 mammography units from 6 different manufacturers were collected. The analysis showed that the data reflects the practice in Switzerland.The results revealed that the MGD is larger for DBT than for 2D acquisitions for the same CBT. From 20-30mm to 90-100mm of CBT, the 75th percentile of the MGD values obtained increased from 0.81mGy to 2.55mGy for 2D CC acquisitions, from 0.83mGy to 2.96mGy for 2D MLO acquisitions, from 1.22mGy to 3.66mGy for DBT CC acquisitions and from 1.33mGy to 4.04mGy for DBT MLO acquisitions.
Conclusion:
The results of the survey allow us to propose Swiss DRLs for mammography according to the examination type (2D/DBT), projection (CC/MLO) and CBT. The proposed values are very satisfactory in comparison with other studies.
.
Collapse
|
4
|
Task-based detectability in anatomical background in digital mammography, digital breast tomosynthesis and synthetic mammography. Phys Med Biol 2024; 69:025017. [PMID: 38214048 DOI: 10.1088/1361-6560/ad1766] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Accepted: 12/20/2023] [Indexed: 01/13/2024]
Abstract
Objective.Determining the detectability of targets for the different imaging modalities in mammography in the presence of anatomical background noise is challenging. This work proposes a method to compare the image quality and detectability of targets in digital mammography (DM), digital breast tomosynthesis (DBT) and synthetic mammography.Approach. The low-frequency structured noise produced by a water phantom with acrylic spheres was used to simulate anatomical background noise for the different types of images. A method was developed to apply the non-prewhitening observer model with eye filter (NPWE) in these conditions. A homogeneous poly(methyl) methacrylate phantom with a 0.2 mm thick aluminium disc was used to calculate 2D in-plane modulation transfer function (MTF), noise power spectrum (NPS), noise equivalent quanta, and system detective quantum efficiency for 30, 50 and 70 mm thicknesses. The in-depth MTFs of DBT volumes were determined using a thin tungsten wire. The MTF, system NPS and anatomical NPS were used in the NPWE model to calculate the threshold gold thickness of the gold discs contained in the CDMAM phantom, which was taken as reference. Main results.The correspondence between the NPWE model and the CDMAM phantom (linear Pearson correlation 0.980) yielded a threshold detectability index that was used to determine the threshold diameter of spherical microcalcifications and masses. DBT imaging improved the detection of masses, which depended mostly on the reduction of anatomical background noise. Conversely, DM images yielded the best detection of microcalcifications.Significance.The method presented in this study was able to quantify image quality and object detectability for the different imaging modalities and levels of anatomical background noise.
Collapse
|
5
|
Clinical commissioning of the first point-of-care spectral photon-counting CT for the upper extremities. Med Phys 2023; 50:2844-2859. [PMID: 36807109 DOI: 10.1002/mp.16313] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2022] [Revised: 01/14/2023] [Accepted: 01/15/2023] [Indexed: 02/23/2023] Open
Abstract
BACKGROUND Acceptance testing and quality assurance (QA) of computed tomography (CT) scans are of great importance to ensure the appropriate performance of the systems. However, current standards and guidelines do not include a dedicated QA program for spectral photon-counting CT (SPCCT), nor adapted tolerance levels. PURPOSE To evaluate the technical performance, in terms of image quality and radiation dose, of the first point-of-care SPCCT for the upper extremities (MARS Extremity 5X120, MARS Bioimaging Ltd., Christchurch, New Zealand) and to establish a comprehensive QA program. METHODS The specific dimensions of the scanner with a 125 mm diameter gantry and a small voxel size of 0.1 × 0.1 × 0.1 mm3 require the use of suitable phantoms and evaluation techniques. Indicators such as CT number accuracy, image noise, uniformity, and slice thickness were assessed to characterize the image quality. The in-plane and longitudinal spatial resolutions were evaluated by means of the modulation transfer function (MTF). Noise power spectra (NPS) were calculated to further evaluate the image noise. Material identification capabilities were assessed using clinically relevant high-Z materials (iodine, gold, gadolinium, and calcium). A 100-mm diameter CTDI-like phantom was used to measure the dose indices. A complete radiation survey was carried out to measure the radiation exposure at different points around the scanner. RESULTS The proposed QA program is based on international and local recommendations as well as practical experience. It includes standardised CT tests and SPCCT-specific methods. Additional methodologies to further assess the system performance are also presented. Tolerance levels are discussed and revised when appropriate. Both in-plane and longitudinal high spatial resolutions were evidenced by the MTF measurements with 1.8 lp· mm-1 and 5.0 lp· mm-1 at 10%, respectively. The calculated effective slice thickness ranged between 0.15 and 0.16 mm for the five energy bins and for a reconstructed voxel size of 0.1 × 0.1 × 0.1 mm3 . Reference values of the linear attenuation coefficient of water have been calculated and used to assess the CT number uniformity of water. Evaluation of the CT number accuracy and stability of various clinically relevant materials showed excellent spectral correlation and linearity between HU values and concentrations (r2 > 0.99). The NPS showed less noise correlation between slices than within transverse slice, as well as a systematic increase at low spatial frequencies. The volume CT dose index (CTDI v o l $_{vol}$ ) for a custom-made 100 mm diameter phantom was 9.32 mGy. Radiation measurements around the scanner showed that it is completely shielded except for the access port, and that no additional protective measures are necessary for the patient. CONCLUSIONS A routine QA framework for SPCCT systems has been proposed. Image quality and radiation dose were assessed using newly designed phantoms, relevant metrics, and automated algorithms. Baseline values were established and tolerance levels discussed for the MARS SPCCT scanner based on collected data and international recommendations.
Collapse
|
6
|
Virtual Noncontrast Abdominal Imaging with Photon-counting Detector CT. Radiology 2022; 305:107-115. [PMID: 35670712 DOI: 10.1148/radiol.213260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Background Accurate CT attenuation and diagnostic quality of virtual noncontrast (VNC) images acquired with photon-counting detector (PCD) CT are needed to replace true noncontrast (TNC) scans. Purpose To assess the attenuation errors and image quality of VNC images from abdominal PCD CT compared with TNC images. Materials and Methods In this retrospective study, consecutive adult patients who underwent a triphasic examination with PCD CT from July 2021 to October 2021 were included. VNC images were reconstructed from arterial and portal venous phase CT. The absolute attenuation error of VNC compared with TNC images was measured in multiple structures by two readers. Then, two readers blinded to image reconstruction assessed the overall image quality, image noise, noise texture, and delineation of small structures using five-point discrete visual scales (5 = excellent, 1 = nondiagnostic). Overall image quality greater than or equal to 3 was deemed diagnostic. In a phantom, noise texture, spatial resolution, and detectability index were assessed. A detectability index greater than or equal to 5 indicated high diagnostic accuracy. Interreader agreement was evaluated using the Krippendorff α coefficient. The paired t test and Friedman test were applied to compare objective and subjective results. Results Overall, 100 patients (mean age, 72 years ± 10 [SD]; 81 men) were included. In patients, VNC image attenuation values were consistent between readers (α = .60), with errors less than 5 HU in 76% and less than 10 HU in 95% of measurements. There was no evidence of a difference in error of VNC images from arterial or portal venous phase CT (3.3 HU vs 3.5 HU, P = .16). Subjective image quality was rated lower in VNC images for all categories (all, P < .001). Diagnostic quality of VNC images was reached in 99% and 100% of patients for readers 1 and 2, respectively. In the phantom, VNC images exhibited 33% higher noise, blotchier noise texture, similar spatial resolution, and inferior but overall good image quality (detectability index >20) compared with TNC images. Conclusion Abdominal virtual noncontrast images from the arterial and portal venous phase of photon-counting detector CT yielded accurate CT attenuation and good image quality compared with true noncontrast images. © RSNA, 2022 Online supplemental material is available for this article See also the editorial by Sosna in this issue.
Collapse
|
7
|
X-ray imaging detector for radiological applications adapted to the context and requirements of low- and middle-income countries. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2022; 93:034102. [PMID: 35364973 DOI: 10.1063/5.0077985] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Accepted: 02/20/2022] [Indexed: 06/14/2023]
Abstract
This paper describes the development of a novel medical x-ray imaging system adapted to the needs and constraints of low- and middle-income countries. The developed system is based on an indirect conversion chain: a scintillator plate produces visible light when excited by the x rays, and then, a calibrated multi-camera architecture converts the visible light from the scintillator into a set of digital images. The partial images are then unwarped, enhanced, and stitched through parallel field programmable gate array processing units and specialized software. All the detector components were carefully selected focusing on optimizing the system's image quality, robustness, cost-effectiveness, and capability to work in harsh tropical environments. With this aim, different customized and commercial components were characterized. The resulting detector can generate high quality medical diagnostic images with detective quantum efficiency levels up to 60% (@2.34 μGy), even under harsh environments, i.e., 60 °C and 98% humidity.
Collapse
|
8
|
Quantum Iterative Reconstruction for Low-Dose Ultra-High-Resolution Photon-Counting Detector CT of the Lung. Diagnostics (Basel) 2022; 12:522. [PMID: 35204611 PMCID: PMC8871296 DOI: 10.3390/diagnostics12020522] [Citation(s) in RCA: 30] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Revised: 02/10/2022] [Accepted: 02/14/2022] [Indexed: 02/06/2023] Open
Abstract
The aim of this study was to characterize image quality and to determine the optimal strength levels of a novel iterative reconstruction algorithm (quantum iterative reconstruction, QIR) for low-dose, ultra-high-resolution (UHR) photon-counting detector CT (PCD-CT) of the lung. Images were acquired on a clinical dual-source PCD-CT in the UHR mode and reconstructed with a sharp lung reconstruction kernel at different strength levels of QIR (QIR-1 to QIR-4) and without QIR (QIR-off). Noise power spectrum (NPS) and target transfer function (TTF) were analyzed in a cylindrical phantom. 52 consecutive patients referred for low-dose UHR chest PCD-CT were included (CTDIvol: 1 ± 0.6 mGy). Quantitative image quality analysis was performed computationally which included the calculation of the global noise index (GNI) and the global signal-to-noise ratio index (GSNRI). The mean attenuation of the lung parenchyma was measured. Two readers graded images qualitatively in terms of overall image quality, image sharpness, and subjective image noise using 5-point Likert scales. In the phantom, an increase in the QIR level slightly decreased spatial resolution and considerably decreased noise amplitude without affecting the frequency content. In patients, GNI decreased from QIR-off (202 ± 34 HU) to QIR-4 (106 ± 18 HU) (p < 0.001) by 48%. GSNRI increased from QIR-off (4.4 ± 0.8) to QIR-4 (8.2 ± 1.6) (p < 0.001) by 87%. Attenuation of lung parenchyma was highly comparable among reconstructions (QIR-off: -849 ± 53 HU to QIR-4: -853 ± 52 HU, p < 0.001). Subjective noise was best in QIR-4 (p < 0.001), while QIR-3 was best for sharpness and overall image quality (p < 0.001). Thus, our phantom and patient study indicates that QIR-3 provides the optimal iterative reconstruction level for low-dose, UHR PCD-CT of the lungs.
Collapse
|
9
|
Performance of Spectral Photon-Counting Coronary CT Angiography and Comparison with Energy-Integrating-Detector CT: Objective Assessment with Model Observer. Diagnostics (Basel) 2021; 11:2376. [PMID: 34943611 PMCID: PMC8700425 DOI: 10.3390/diagnostics11122376] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Revised: 12/02/2021] [Accepted: 12/14/2021] [Indexed: 11/16/2022] Open
Abstract
AIMS To evaluate spectral photon-counting CT's (SPCCT) objective image quality characteristics in vitro, compared with standard-of-care energy-integrating-detector (EID) CT. METHODS We scanned a thorax phantom with a coronary artery module at 10 mGy on a prototype SPCCT and a clinical dual-layer EID-CT under various conditions of simulated patient size (small, medium, and large). We used filtered back-projection with a soft-tissue kernel. We assessed noise and contrast-dependent spatial resolution with noise power spectra (NPS) and target transfer functions (TTF), respectively. Detectability indices (d') of simulated non-calcified and lipid-rich atherosclerotic plaques were computed using the non-pre-whitening with eye filter model observer. RESULTS SPCCT provided lower noise magnitude (9-38% lower NPS amplitude) and higher noise frequency peaks (sharper noise texture). Furthermore, SPCCT provided consistently higher spatial resolution (30-33% better TTF10). In the detectability analysis, SPCCT outperformed EID-CT in all investigated conditions, providing superior d'. SPCCT reached almost perfect detectability (AUC ≈ 95%) for simulated 0.5-mm-thick non-calcified plaques (for large-sized patients), whereas EID-CT had lower d' (AUC ≈ 75%). For lipid-rich atherosclerotic plaques, SPCCT achieved 85% AUC vs. 77.5% with EID-CT. CONCLUSIONS SPCCT outperformed EID-CT in detecting simulated coronary atherosclerosis and might enhance diagnostic accuracy by providing lower noise magnitude, markedly improved spatial resolution, and superior lipid core detectability.
Collapse
|
10
|
A novel method to assess the spatiotemporal image quality in fluoroscopy. Phys Med Biol 2021; 66. [PMID: 34808602 DOI: 10.1088/1361-6560/ac3c15] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Accepted: 11/22/2021] [Indexed: 11/11/2022]
Abstract
Objectives. The planar formulation of the noise equivalent quanta (NEQ) and detective quantum efficiency (DQE) used to assess the image quality of projection images does not deal with the influence of temporal resolution on signal blurring and image noise. These metrics require correction factors based on temporal resolution when used for dynamic imaging systems such as fluoroscopy. Additionally, the standard NEQ and detector DQE are determined on pre-processed images in scatter-free conditions for effective energies produced by additional aluminium or copper filters that are not representative of clinical fluoroscopic procedures. In this work, we developed a method to measure 'frame NEQ' and 'frame system DQE' which include the temporal frequency bandwidth and consider the anti-scatter grid, the detector and the image processing procedures for beam qualities with scatter fractions representative of clinical use.Approach. We used a solid water phantom to simulate a patient and a thin copper disc to measure the spatial resolution. The copper disc, set in uniform rectilinear motion in the image plane, assessed the temporal resolution. These new metrics were tested on two fluoroscopy systems, a C-arm and a floor-mounted cardiology, for multiple parameters: phantom thicknesses from 5 to 20 cm, frame rates from 3 to 30 fps, spatial and temporal image processing of different weights.Main results.The frame NEQ correctly described the image quality for different scatter conditions, temporal resolutions and image processing techniques. The frame system DQE varied between 0.38 and 0.65 within the different beam and scatter conditions, and correctly mitigated the influence of spatial and temporal image processing.Significance.This study introduces and validates an unbiased formulation of in-plane NEQ and system DQE to assess the spatiotemporal image quality of fluoroscopy systems.
Collapse
|
11
|
|
12
|
Abstract
A rigorous 2D analysis of signal and noise transfer applied to reconstructed planes in digital breast tomosynthesis (DBT) is necessary for system characterization and optimization. This work proposes a method for assessing technical image quality and system detective quantum efficiency (DQEsys) for reconstructed planes in DBT. Measurements of 2D in-plane modulation transfer function (MTF) and noise power spectrum (NPS) were made on five DBT systems using different acquisition parameters, reconstruction algorithms and plane spacing. This work develops the noise equivalent quanta (NEQ), DQEsys and detectability index (d') calculated using a non-prewhitening model observer with eye filter (NPWE) for reconstructed DBT planes. The images required for this implementation were acquired using a homogeneous test object of thickness 40 mm poly(methyl) methacrylate plus 0.5 mm Al; 2D MTF was calculated from an Al disc of thickness 0.2 mm and diameter 50 mm positioned within the phantom. The radiant contrast of the MTF disc and the air kerma at the system input were used as normalization factors. The NPWE detectability index was then compared to the in-plane contrast-detail (c-d) threshold measured using the CDMAM phantom. The MTF and NPS measured on the different systems showed a strong anisotropy, consistent with the cascaded models developed in the literature for DBT. Detectability indices calculated from the measured MTF and NPS successfully predicted changes in c-d detectability for details between 0.1 mm and 2.0 mm, for DBT plane spacings between 0.5 mm and 10 mm, and for air kerma values at the system input between 157 µGy and 1170 μGy. The linear Pearson correlation between the detectability index and threshold gold thickness of the CDMAM phantom was -0.996. The method implements a parametric means of assessing the technical image quality of reconstructed DBT planes, providing valuable information for optimization of DBT systems.
Collapse
|
13
|
Generalized SDNR analysis based on signal and noise power. Phys Med 2019; 64:10-15. [DOI: 10.1016/j.ejmp.2019.06.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Revised: 05/15/2019] [Accepted: 06/12/2019] [Indexed: 11/28/2022] Open
|
14
|
Optimal slice thickness for object detection with longitudinal partial volume effects in computed tomography [JACMP, 18(1) 251-259, 2017]. J Appl Clin Med Phys 2018; 19:408. [PMID: 29851263 PMCID: PMC5978686 DOI: 10.1002/acm2.12330] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022] Open
|
15
|
A comprehensive model for x-ray projection imaging system efficiency and image quality characterization in the presence of scattered radiation. Phys Med Biol 2017; 62:5691-5722. [DOI: 10.1088/1361-6560/aa75bc] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
16
|
Optimal slice thickness for object detection with longitudinal partial volume effects in computed tomography. J Appl Clin Med Phys 2016; 18:251-259. [PMID: 28291920 PMCID: PMC5689876 DOI: 10.1002/acm2.12005] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2016] [Accepted: 09/05/2016] [Indexed: 11/16/2022] Open
Abstract
Longitudinal partial volume effects (z‐axial PVE), which occur when an object partly occupies a slice, degrade image resolution and contrast in computed tomography (CT). Z‐axial PVE is unavoidable for subslice objects and reduces their contrast according to their fraction contained within the slice. This effect can be countered using a smaller slice thickness, but at the cost of an increased image noise or radiation dose. The aim of this study is to offer a tool for optimizing the reconstruction parameters (slice thickness and slice spacing) in CT protocols in the case of partial volume effects. This optimization is based on the tradeoff between axial resolution and noise. For that purpose, we developed a simplified analytical model investigating the average statistical effect of z‐axial PVE on contrast and contrast‐to‐noise ratio (CNR). A Catphan 500 phantom was scanned with various pitches and CTDI and reconstructed with different slice thicknesses to assess the visibility of subslice targets that simulate low contrast anatomical features present in CT exams. The detectability score of human observers was used to rank the perceptual image quality against the CNR. Contrast and CNR reduction due to z‐axial PVE measured on experimental data were first compared to numerical calculations and then to the analytical model. Compared to numerical calculations, the simplified algebraic model slightly overestimated the contrast but the differences remained below 5%. It could determine the optimal reconstruction parameters that maximize the objects visibility for a given dose in the case of z‐axial PVE. An optimal slice thickness equal to three‐fourth of the object width was correctly proposed by the model for nonoverlapping slices. The tradeoff between detectability and dose is maximized for a slice spacing of half the slice thickness associated with a slice width equal to the characteristic object width.
Collapse
|
17
|
Difference in performance between 3D and 4D CBCT for lung imaging: a dose and image quality analysis. J Appl Clin Med Phys 2016; 17:97-106. [PMID: 27929485 PMCID: PMC5690502 DOI: 10.1120/jacmp.v17i6.6459] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2016] [Revised: 07/26/2016] [Accepted: 07/25/2016] [Indexed: 12/01/2022] Open
Abstract
The study was to describe and to compare the performance of 3D and 4D CBCT imaging modalities by measuring and analyzing the delivered dose and the image quality. The 3D (Chest) and 4D (Symmetry) CBCT Elekta XVI lung IGRT protocols were analyzed. Dose profiles were measured with TLDs inside a dedicated phantom. The dosimetric indicator cone‐beam dose index (CBDI) was evaluated. The image quality analysis was performed by assessing the contrast transfer function (CTF), the noise power spectrum (NPS) and the noise‐equivalent quanta (NEQ). Artifacts were also evaluated by simulating irregular breathing variations. The two imaging modalities showed different dose distributions within the phantom. At the center, the 3D CBCT delivered twice the dose of the 4D CBCT. The CTF was strongly reduced by motion compared to static conditions, resulting in a CTF reduction of 85% for the 3D CBCT and 65% for the 4D CBCT. The amplitude of the NPS was two times higher for the 4D CBCT than for the 3D CBCT. In the presence of motion, the NEQ of the 4D CBCT was 50% higher than the 3D CBCT. In the presence of breathing irregularities, the 4D CBCT protocol was mainly affected by view‐aliasing artifacts, which were typically cone‐beam artifacts, while the 3D CBCT protocol was mainly affected by duplication artifacts. The results showed that the 4D CBCT ensures a reasonable dose and better image quality when moving targets are involved compared to 3D CBCT. Therefore, 4D CBCT is a reliable imaging modality for lung free‐breathing radiation therapy. PACS number(s): 87.57.C‐, 87.57.uq, 87.53.Ly
Collapse
|
18
|
CHARACTERISING THE EOS SLOT-SCANNING SYSTEM WITH THE EFFECTIVE DETECTIVE QUANTUM EFFICIENCY. RADIATION PROTECTION DOSIMETRY 2016; 169:319-324. [PMID: 26538617 DOI: 10.1093/rpd/ncv451] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
As opposed to the standard detective quantum efficiency (DQE), effective DQE (eDQE) is a figure of merit that allows comparing the performances of imaging systems in the presence of scatter rejection devices. The geometry of the EOS™ slot-scanning system is such that the detector is self-collimated and rejects scattered radiation. In this study, the EOS system was characterised using the eDQE in imaging conditions similar to those used in clinical practice: with phantoms of different widths placed in the X-ray beam, for various incident air kerma and tube voltages corresponding to the phantom thickness. Scatter fractions in EOS images were extremely low, around 2 % for all configurations. Maximum eDQE values spanned 9-14.8 % for a large range of air kerma at the detector plane from 0.01 to 1.34 µGy. These figures were obtained with non-optimised EOS setting but still over-performed most of the maximum eDQEs recently assessed for various computed radiology and digital radiology systems with antiscatter grids.
Collapse
|
19
|
Abstract
A version of cascaded systems analysis was developed specifically with the aim of studying quantum noise propagation in x-ray detectors. Signal and quantum noise propagation was then modelled in four types of x-ray detectors used for digital mammography: four flat panel systems, one computed radiography and one slot-scan silicon wafer based photon counting device. As required inputs to the model, the two dimensional (2D) modulation transfer function (MTF), noise power spectra (NPS) and detective quantum efficiency (DQE) were measured for six mammography systems that utilized these different detectors. A new method to reconstruct anisotropic 2D presampling MTF matrices from 1D radial MTFs measured along different angular directions across the detector is described; an image of a sharp, circular disc was used for this purpose. The effective pixel fill factor for the FP systems was determined from the axial 1D presampling MTFs measured with a square sharp edge along the two orthogonal directions of the pixel lattice. Expectation MTFs were then calculated by averaging the radial MTFs over all possible phases and the 2D EMTF formed with the same reconstruction technique used for the 2D presampling MTF. The quantum NPS was then established by noise decomposition from homogenous images acquired as a function of detector air kerma. This was further decomposed into the correlated and uncorrelated quantum components by fitting the radially averaged quantum NPS with the radially averaged EMTF(2). This whole procedure allowed a detailed analysis of the influence of aliasing, signal and noise decorrelation, x-ray capture efficiency and global secondary gain on NPS and detector DQE. The influence of noise statistics, pixel fill factor and additional electronic and fixed pattern noises on the DQE was also studied. The 2D cascaded model and decompositions performed on the acquired images also enlightened the observed quantum NPS and DQE anisotropy.
Collapse
|
20
|
A model-based approach of scatter dose contributions and efficiency of apron shielding for radiation protection in CT. Phys Med 2015; 31:889-896. [PMID: 26112350 DOI: 10.1016/j.ejmp.2015.06.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2014] [Revised: 06/02/2015] [Accepted: 06/05/2015] [Indexed: 11/19/2022] Open
Abstract
Given the contribution of scattered radiations to patient dose in CT, apron shielding is often used for radiation protection. In this study the efficiency of apron was assessed with a model-based approach of the contributions of the four scatter sources in CT, i.e. external scattered radiations from the tube and table, internal scatter from the patient and backscatter from the shielding. For this purpose, CTDI phantoms filled with thermoluminescent dosimeters were scanned without apron, and then with an apron at 0, 2.5 and 5 cm from the primary field. Scatter from the tube was measured separately in air. The scatter contributions were separated and mathematically modelled. The protective efficiency of the apron was low, only 1.5% in scatter dose reduction on average. The apron at 0 cm from the beam lowered the dose by 7.5% at the phantom bottom but increased the dose by 2% at the top (backscatter) and did not affect the centre. When the apron was placed at 2.5 or 5 cm, the results were intermediate to the one obtained with the shielding at 0 cm and without shielding. The apron effectiveness is finally limited to the small fraction of external scattered radiation.
Collapse
|
21
|
Comparison of the polynomial model against explicit measurements of noise components for different mammography systems. Phys Med Biol 2014; 59:5741-61. [DOI: 10.1088/0031-9155/59/19/5741] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
22
|
Corrigendum:Update on the non-prewhitening model observer in computed tomography for the assessment of the adaptive statistical and model-based iterative reconstruction algorithms (2014 Phys. Med. Biol. 59 4047–64). Phys Med Biol 2014. [DOI: 10.1088/0031-9155/59/17/5203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
23
|
Update on the non-prewhitening model observer in computed tomography for the assessment of the adaptive statistical and model-based iterative reconstruction algorithms. Phys Med Biol 2014; 59:4047-64. [DOI: 10.1088/0031-9155/59/4/4047] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
24
|
Occupational and patient exposure as well as image quality for full spine examinations with the EOS imaging system. Med Phys 2014; 41:063901. [DOI: 10.1118/1.4873333] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
25
|
Image quality assessment in digital mammography: part II. NPWE as a validated alternative for contrast detail analysis. Phys Med Biol 2011; 56:4221-38. [DOI: 10.1088/0031-9155/56/14/003] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
26
|
Image quality assessment in digital mammography: part I. Technical characterization of the systems. Phys Med Biol 2011; 56:4201-20. [DOI: 10.1088/0031-9155/56/14/002] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
27
|
Using a NPWE model observer to assess suitable image quality for a digital mammography quality assurance programme. RADIATION PROTECTION DOSIMETRY 2010; 139:459-462. [PMID: 20395413 DOI: 10.1093/rpd/ncq010] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
A method of objectively determining imaging performance for a mammography quality assurance programme for digital systems was developed. The method is based on the assessment of the visibility of a spherical microcalcification of 0.2 mm using a quasi-ideal observer model. It requires the assessment of the spatial resolution (modulation transfer function) and the noise power spectra of the systems. The contrast is measured using a 0.2-mm thick Al sheet and Polymethylmethacrylate (PMMA) blocks. The minimal image quality was defined as that giving a target contrast-to-noise ratio (CNR) of 5.4. Several evaluations of this objective method for evaluating image quality in mammography quality assurance programmes have been considered on computed radiography (CR) and digital radiography (DR) mammography systems. The measurement gives a threshold CNR necessary to reach the minimum standard image quality required with regards to the visibility of a 0.2-mm microcalcification. This method may replace the CDMAM image evaluation and simplify the threshold contrast visibility test used in mammography quality.
Collapse
|
28
|
Abstract
An objective analysis of image quality parameters was performed for six digital mammography systems. The presampled modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE) for the systems were determined at different doses, for 28 kVp with a Mo/Mo or W/Al target/filter combination and 2 mm of additional aluminium filtration. The flat-panel units have higher MTF and DQE in the mid to high frequency range than standard CR systems. The highest DQE, over the whole dose range, is for the slit-scanning direct photon counting system. Dual-side read CR can overcome the inherent x-ray absorption and signal collection limitations of standard CR mammography, improving the low-frequency DQE by 40%, to the same level as full-field systems, but it does not improve the poor spatial resolution of phosphor.
Collapse
|
29
|
Abstract
Imaging of biological samples has been performed with a variety of techniques for example electromagnetic waves, electrons, neutrons, ultrasound and X-rays. Also conventional X-ray imaging represents the basis of medical diagnostic imaging, it remains of limited use in this application because it is based solely on the differential absorption of X-rays by tissues. Coherent and bright photon beams, such as those produced by third-generation synchrotron X-ray sources, provide further information on subtle X-ray phase changes at matter interfaces. This complements conventional X-ray absorption by edge enhancement phenomena. Thus, phase contrast imaging has the potential to improve the detection of structures on images by detecting those structures that are invisible with X-ray absorption imaging. Images of a weakly absorbing nylon fibre were recorded in in-line holography geometry using a high resolution low-noise CCD camera at the ESRF in Grenoble. The method was also applied to improve image contrast for images of biological tissues. This paper presents phase contrast microradiographs of vascular tree casts and images of a housefly. These reveal very fine structures, that remain invisible with conventional absorption contrast only.
Collapse
|
30
|
Abstract
In our recent paper by Monnin et al. [Med. Phys. 33, 411-420 (2006)], an objective analysis of the relative performance of a computed radiography (CR) system using both standard single-side (ST-VI) and prototype dual-side read (ST-BD) plates was reported. The presampled modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) for the systems were determined at three different beam qualities representative of paediatric chest radiography, at an entrance detector air kerma of 5 microGy. Experiments demonstrated that, compared to the standard single-side read system, the MTF for the dual-side read system was slightly reduced, but a significant decrease in image noise resulted in a marked increase in DQE (+40%) in the low spatial frequency range. However, the DQE improvement for the ST-BD plate decreased with increasing spatial frequency, and, at spatial frequencies above 2.2 mm(-1), the DQE of the dual-side read system was lower than that of the single-side one.
Collapse
|
31
|
An image quality comparison of standard and dual-side read CR systems for paediatric radiology. Med Phys 2006; 33:411-20. [PMID: 16532949 DOI: 10.1118/1.2163392] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
An objective analysis of image quality parameters was performed for a computed radiography (CR) system using both standard single-side and prototype dual-side read plates. The pre-sampled modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) for the systems were determined at three different beam qualities representative of pediatric chest radiography, at an entrance detector air kerma of 5 microGy. The NPS and DQE measurements were realized under clinically relevant x-ray spectra for pediatric radiology, including x-ray scatter radiations. Compared to the standard single-side read system, the MTF for the dual-side read system is reduced, but this is offset by a significant decrease in image noise, resulting in a marked increase in DQE (+40%) in the low spatial frequency range. Thus, for the same image quality, the new technology permits the CR system to be used at a reduced dose level.
Collapse
|
32
|
A comparison of the imaging characteristics of the new Kodak Hyper Speed G film with the current T-MAT G/RA film and the CR 9000 system. Phys Med Biol 2005; 50:4541-52. [PMID: 16177488 DOI: 10.1088/0031-9155/50/19/008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Three standard radiation qualities (RQA 3, RQA 5 and RQA 9) and two screens, Kodak Lanex Regular and Insight Skeletal, were used to compare the imaging performance and dose requirements of the new Kodak Hyper Speed G and the current Kodak T-MAT G/RA medical x-ray films. The noise equivalent quanta (NEQ) and detective quantum efficiencies (DQE) of the four screen-film combinations were measured at three gross optical densities and compared with the characteristics for the Kodak CR 9000 system with GP (general purpose) and HR (high resolution) phosphor plates. The new Hyper Speed G film has double the intrinsic sensitivity of the T-MAT G/RA film and a higher contrast in the high optical density range for comparable exposure latitude. By providing both high sensitivity and high spatial resolution, the new film significantly improves the compromise between dose and image quality. As expected, the new film has a higher noise level and a lower signal-to-noise ratio than the standard film, although in the high frequency range this is compensated for by a better resolution, giving better DQE results--especially at high optical density. Both screen-film systems outperform the phosphor plates in terms of MTF and DQE for standard imaging conditions (Regular screen at RQA 5 and RQA 9 beam qualities). At low energy (RQA 3), the CR system has a comparable low-frequency DQE to screen-film systems when used with a fine screen at low and middle optical densities, and a superior low-frequency DQE at high optical density.
Collapse
|
33
|
Abstract
This work compares the detector performance and image quality of the new Kodak Min-R EV mammography screen-film system with the Fuji CR Profect detector and with other current mammography screen-film systems from Agfa, Fuji and Kodak. Basic image quality parameters (MTF, NPS, NEQ and DQE) were evaluated for a 28 kV Mo/Mo (HVL = 0.646 mm Al) beam using different mAs exposure settings. Compared with other screen-film systems, the new Kodak Min-R EV detector has the highest contrast and a low intrinsic noise level, giving better NEQ and DQE results, especially at high optical density. Thus, the properties of the new mammography film approach those of a fine mammography detector, especially at low frequency range. Screen-film systems provide the best resolution. The presampling MTF of the digital detector has a value of 15% at the Nyquist frequency and, due to the spread size of the laser beam, the use of a smaller pixel size would not permit a significant improvement of the detector resolution. The dual collection reading technology increases significantly the low frequency DQE of the Fuji CR system that can at present compete with the most efficient mammography screen-film systems.
Collapse
|
34
|
Repeated injections of 131I-rituximab show patient-specific stable biodistribution and tissue kinetics. Eur J Nucl Med Mol Imaging 2005; 32:943-51. [PMID: 15824926 DOI: 10.1007/s00259-005-1798-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2005] [Accepted: 02/17/2005] [Indexed: 11/26/2022]
Abstract
PURPOSE It is generally assumed that the biodistribution and pharmacokinetics of radiolabelled antibodies remain similar between dosimetric and therapeutic injections in radioimmunotherapy. However, circulation half-lives of unlabelled rituximab have been reported to increase progressively after the weekly injections of standard therapy doses. The aim of this study was to evaluate the evolution of the pharmacokinetics of repeated 131I-rituximab injections during treatment with unlabelled rituximab in patients with non-Hodgkin's lymphoma (NHL). METHODS Patients received standard weekly therapy with rituximab (375 mg/m2) for 4 weeks and a fifth injection at 7 or 8 weeks. Each patient had three additional injections of 185 MBq 131I-rituximab in either treatment weeks 1, 3 and 7 (two patients) or weeks 2, 4 and 8 (two patients). The 12 radiolabelled antibody injections were followed by three whole-body (WB) scintigraphic studies during 1 week and blood sampling on the same occasions. Additional WB scans were performed after 2 and 4 weeks post 131I-rituximab injection prior to the second and third injections, respectively. RESULTS A single exponential radioactivity decrease for WB, liver, spleen, kidneys and heart was observed. Biodistribution and half-lives were patient specific, and without significant change after the second or third injection compared with the first one. Blood T(1/2)beta, calculated from the sequential blood samples and fitted to a bi-exponential curve, was similar to the T(1/2) of heart and liver but shorter than that of WB and kidneys. Effective radiation dose calculated from attenuation-corrected WB scans and blood using Mirdose3.1 was 0.53+0.05 mSv/MBq (range 0.48-0.59 mSv/MBq). Radiation dose was highest for spleen and kidneys, followed by heart and liver. CONCLUSION These results show that the biodistribution and tissue kinetics of 131I-rituximab, while specific to each patient, remained constant during unlabelled antibody therapy. RIT radiation doses can therefore be reliably extrapolated from a preceding dosimetry study.
Collapse
|
35
|
Performance comparison of an active matrix flat panel imager, computed radiography system, and a screen-film system at four standard radiation qualities. Med Phys 2005; 32:343-50. [PMID: 15789578 DOI: 10.1118/1.1843451] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Four standard radiation qualities (from RQA 3 to RQA 9) were used to compare the imaging performance of a computed radiography (CR) system (general purpose and high resolution phosphor plates of a Kodak CR 9000 system), a selenium-based direct flat panel detector (Kodak Direct View DR 9000), and a conventional screen-film system (Kodak T-MAT L/RA film with a 3M Trimax Regular screen of speed 400) in conventional radiography. Reference exposure levels were chosen according to the manufacturer's recommendations to be representative of clinical practice (exposure index of 1700 for digital systems and a film optical density of 1.4). With the exception of the RQA 3 beam quality, the exposure levels needed to produce a mean digital signal of 1700 were higher than those needed to obtain a mean film optical density of 1.4. In spite of intense developments in the field of digital detectors, screen-film systems are still very efficient detectors for most of the beam qualities used in radiology. An important outcome of this study is the behavior of the detective quantum efficiency of the digital radiography (DR) system as a function of beam energy. The practice of users to increase beam energy when switching from a screen-film system to a CR system, in order to improve the compromise between patient dose and image quality, might not be appropriate when switching from screen-film to selenium-based DR systems.
Collapse
|
36
|
A strategy to qualify the performance of radiographic monitors. RADIATION PROTECTION DOSIMETRY 2005; 114:192-7. [PMID: 15933107 DOI: 10.1093/rpd/nch565] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
The purpose of this work was to compare standard desktop display systems with dedicated medical display systems. The set of image tests proposed by the American Association of Physicists in Medicine (AAPM TG18) was used to assess a Philips 107S desktop display system and a Siemens medical display. Three observers performed the subjective assessment, in a non-concerted manner. The objective assessment was performed using a CCD camera according to the AAPM TG18 procedure. The results clearly demonstrate the inadequacy of standard desktop display systems in the framework of diagnostic radiology. Moreover, a good correlation between the subjective and objective assessment methods was obtained.
Collapse
|
37
|
Influence of detector collimation on SNR in four different MDCT scanners using a reconstructed slice thickness of 5�mm. Eur Radiol 2004; 14:1866-72. [PMID: 15278412 DOI: 10.1007/s00330-004-2420-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2004] [Revised: 06/07/2004] [Accepted: 06/14/2004] [Indexed: 10/26/2022]
Abstract
The purpose of this paper is to compare the influence of detector collimation on the signal-to-noise ratio (SNR) for a 5.0 mm reconstructed slice thickness for four multi-detector row CT (MDCT) units. SNRs were measured on Catphan test phantom images from four MDCT units: a GE LightSpeed QX/I, a Marconi MX 8000, a Toshiba Aquilion and a Siemens Volume Zoom. Five-millimetre-thick reconstructed slices were obtained from acquisitions performed using detector collimations of 2.0-2.5 mm and 5.0 mm, 120 kV, a 360 degrees tube rotation time of 0.5 s, a wide range of mA and pitch values in the range of 0.75-0.85 and 1.25-1.5. For each set of acquisition parameters, a Wiener spectrum was also calculated. Statistical differences in SNR for the different acquisition parameters were evaluated using a Student's t-test (P<0.05). The influence of detector collimation on the SNR for a 5.0-mm reconstructed slice thickness is different for different MDCT scanners. At pitch values lower than unity, the use of a small detector collimation to produce 5.0-mm thick slices is beneficial for one unit and detrimental for another. At pitch values higher than unity, using a small detector collimation is beneficial for two units. One manufacturer uses different reconstruction filters when switching from a 2.5- to a 5.0-mm detector collimation. For a comparable reconstructed slice thickness, using a smaller detector collimation does not always reduce image noise. Thus, the impact of the detector collimation on image noise should be determined by standard deviation calculations, and also by assessing the power spectra of the noise.
Collapse
|
38
|
Abstract
The aim of this study was to model the edge enhancement effect in in-line holography phase contrast imaging. A simple analytical approach was used to quantify refraction and interference contrasts in terms of beam energy and imaging geometry. The model was applied to predict the peak intensity and frequency of the edge enhancement for images of cylindrical fibers. The calculations were compared with measurements, and the relationship between the spatial resolution of the detector and the amplitude of the phase contrast signal was investigated. Calculations using the analytical model were in good agreement with experimental results for nylon, aluminum and copper wires of 50 to 240 microm diameter, and with numerical simulations based on Fresnel-Kirchhoff theory. A relationship between the defocusing distance and the pixel size of the image detector was established. This analytical model is a useful tool for optimizing imaging parameters in phase contrast in-line holography, including defocusing distance, detector resolution and beam energy.
Collapse
|
39
|
Management of patient dose and image noise in routine pediatric CT abdominal examinations. Eur Radiol 2004; 14:835-41. [PMID: 14722730 DOI: 10.1007/s00330-003-2206-z] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2003] [Revised: 11/05/2003] [Accepted: 12/01/2003] [Indexed: 10/26/2022]
Abstract
The aim was to propose a strategy for finding reasonable compromises between image noise and dose as a function of patient weight. Weighted CT dose index (CTDI(w)) was measured on a multidetector-row CT unit using CTDI test objects of 16, 24 and 32 cm in diameter at 80, 100, 120 and 140 kV. These test objects were then scanned in helical mode using a wide range of tube currents and voltages with a reconstructed slice thickness of 5 mm. For each set of acquisition parameter image noise was measured and the Rose model observer was used to test two strategies for proposing a reasonable compromise between dose and low-contrast detection performance: (1) the use of a unique noise level for all test object diameters, and (2) the use of a unique dose efficacy level defined as the noise reduction per unit dose. Published data were used to define four weight classes and an acquisition protocol was proposed for each class. The protocols have been applied in clinical routine for more than one year. CTDI(vol) values of 6.7, 9.4, 15.9 and 24.5 mGy were proposed for the following weight classes: 2.5-5, 5-15, 15-30 and 30-50 kg with image noise levels in the range of 10-15 HU. The proposed method allows patient dose and image noise to be controlled in such a way that dose reduction does not impair the detection of low-contrast lesions. The proposed values correspond to high- quality images and can be reduced if only high-contrast organs are assessed.
Collapse
MESH Headings
- Adolescent
- Artifacts
- Body Weight/physiology
- Child
- Child, Preschool
- Clinical Protocols/standards
- Humans
- Image Processing, Computer-Assisted/methods
- Infant
- Infant, Newborn
- Models, Theoretical
- Radiation Dosage
- Radiographic Image Enhancement/methods
- Radiography, Abdominal/methods
- Radiography, Abdominal/standards
- Radiometry/methods
- Sensitivity and Specificity
- Signal Processing, Computer-Assisted
- Technology, Radiologic
- Tomography, X-Ray Computed/methods
- Tomography, X-Ray Computed/standards
Collapse
|
40
|
|