1
|
Santos AAL, Corrêa JLG, Machado GGL, Silveira PG, Cruz MS, Nascimento BS. Acerola processing waste: Convective drying with ethanol as pretreatment. Food Res Int 2024; 190:114586. [PMID: 38945606 DOI: 10.1016/j.foodres.2024.114586] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2024] [Revised: 05/31/2024] [Accepted: 06/01/2024] [Indexed: 07/02/2024]
Abstract
The acerola seed is an agro-industrial waste. It is a high moisture content product, rich in bioactive compounds. Drying is an alternative to make this waste available in a safe condition. The use of ethanol as a pretreatment could improve the drying process besides reducing the operation time. This study aimed to investigate the influence of ethanol pretreatment (ET) on the content of bioactive compounds, cell wall thickness, and color. The drying kinetics was studied, and the influence of external and internal resistance was discussed. The samples were immersed in ethanol for 2 min with subsequent convective drying (40 °C and 60 °C; 1 m s-1) until they reached the equilibrium condition. The ET reduced the drying time up to 36.36 %. The external and mixed control of mass transfer were identified as the governing regimes for drying this material, depending on the use of ethanol. ET led to an increase in effective diffusivity, a reduction in cell wall thickness, and preservation of the color of the dried waste. The ET positively impacted the conservation of ascorbic acid compared to untreated dried samples but was not relevant to phenolic compounds, carotenoids, and antioxidant activity. The drying process increased the bioactivity of the anthocyanins. The best condition was drying at 60 °C, pretreated with ethanol.
Collapse
|
2
|
Silveira PG, de P Silva CR, Corrêa JLG, Petri IJ, Borges SV. Process and quality parameters of convective dried yacon: Influence of ethanol treatment. Food Res Int 2024; 176:113863. [PMID: 38163679 DOI: 10.1016/j.foodres.2023.113863] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Revised: 12/04/2023] [Accepted: 12/14/2023] [Indexed: 01/03/2024]
Abstract
Yacon is a highly perishable tuberous root, rich in fructooligosaccharides (FOS). Convective drying preceded by ethanol treatment (ET) is an alternative for increasing shelf life in a shorter process. The aim of this study was to investigate the impact of ET and temperature (50 °C and 70 °C) on quality parameters (fructan retention, total phenolic content, antioxidant capacity, shrinkage, color and microstructural parameters) and process parameters (drying time, drying kinetics, and energy consumption) in the convective drying of yacon slices. The ET induced structural alterations in the tissues and cells that aids in the reduction of drying time up to 28.00 %. ET resulted in an increase in effective diffusivity and leaded to noteworthy reduction in energy consumption (up to 22.72 %). The quality parameters such as color, shrinkage, and total phenolic content showed no significant differences among the treatments. The use of ethanol promoted highest preservation of antioxidant activity; however, it caused degradation of FOS. The ethanol pretreated drying at 50 °C was the better condition for lower consumption and preservation of quality parameters as total phenolic content, antioxidant capacity and fructan retention, but the samples dried at 50 °C were the ones with the highest fructan retention (55.11 ± 2.19 %).
Collapse
|
3
|
Mulatti GC, Joviliano EE, Pereira AH, Fioranelli A, Pereira AA, Brito-Queiroz A, Von Ristow A, Freire LMD, Ferreira MMDV, Lourenço M, De Luccia N, Silveira PG, Yoshida RDA, Fidelis RJR, Boustany SM, de Araujo WJB, de Oliveira JCP. Brazilian Society for Angiology and Vascular Surgery guidelines on abdominal aortic aneurysm. J Vasc Bras 2023; 22:e20230040. [PMID: 38021279 PMCID: PMC10648059 DOI: 10.1590/1677-5449.202300402] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Accepted: 06/15/2023] [Indexed: 12/01/2023] Open
Abstract
The Brazilian Society of Angiology and Vascular Surgery, through the Guidelines Project, presents new Abdominal Aortic Aneurysm Guidelines, on the subject of care for abdominal aortic aneurysm patients. Its development prioritized descriptive guidelines, using the EMBASE, LILACS, and PubMed databases. References include randomized controlled trials, systematic reviews, meta-analyses, and cohort studies. Quality of evidence was evaluated by a pair of coordinators, aided by the RoB 2 Cochrane tool and the Newcastle Ottawa Scale forms. The subjects include juxtarenal aneurysms, infected aneurysms, and new therapeutic techniques, especially endovascular procedures. The current version of the guidelines include important recommendations for the primary topics involving diagnosis, treatment, and follow-up for abdominal aortic aneurysm patients, providing an objective guide for medical practice, based on scientific evidence and widely available throughout Brazil.
Collapse
|
4
|
Bosiers MJ, De Donato G, Torsello G, Silveira PG, Scheinert D, Veroux P, Hendriks J, Maene L, Keirse K, Navarro T, Eckstein HH, Teβarek J, Giaquinta A, van den Eynde W, Verbist J, Callaert J, Deloose K, Bosiers M. ZILVERPASS Study: ZILVER PTX Stent versus Prosthetic Above-the-Knee Bypass Surgery in Femoropopliteal Lesions, 5-year Results. Cardiovasc Intervent Radiol 2023; 46:1348-1358. [PMID: 37670198 PMCID: PMC10547807 DOI: 10.1007/s00270-023-03549-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Accepted: 08/24/2023] [Indexed: 09/07/2023]
Abstract
PURPOSE To report the 60-month safety and effectiveness results of a multicenter, prospective, randomized controlled trial comparing the ZILVER PTX paclitaxel-eluting stent to prosthetic above-the-knee bypass for the treatment of symptomatic TransAtlantic Inter-Society Consensus (TASC) C and D femoropopliteal lesions. MATERIALS AND METHODS Patients were enrolled between October 2013 and July 2017. One of the secondary outcomes was primary patency at 60 months, defined as no evidence of binary restenosis or occlusion within the target lesion or bypass graft based on a duplex ultrasound peak systolic velocity ratio < 2.4 and no clinically-driven target lesion revascularization (TLR) in endovascular cases or reintervention to restore flow in the bypass at 60 months. Survival rates after 5 years were also analyzed. RESULTS 220 patients (mean age 68.6 ± 10.5 years; 159 men) were included and randomized to ZILVER PTX (n = 113, 51.40%) or BYPASS group (n = 107, 48.60%). The 60-month primary patency rate was 49.3% for the ZILVER PTX group versus 40.7% for the bypass group (p = 0.6915). Freedom from TLR was 63.8% for the ZILVER PTX group versus 52.8% for the bypass group (p = 0.2637). At 5 years, no significant difference in survival rate could be seen between the ZILVER PTX and the bypass group (69.1% vs. 71% respectively, p = 0.5503). CONCLUSION Even at 5 years, non-inferior safety and effectiveness results of the ZILVER PTX could be seen. These findings confirmed that the use of ZILVER PTX stents can be considered as a valid alternative for bypass surgery when treating long and complex femoropopliteal lesions.
Collapse
|
5
|
Bosiers M, DE Donato G, Torsello G, Galvagni Silveira P, Deloose K, Scheinert D, Veroux P, Hendriks J, Maene L, Keirse K, Navarro T, Callaert J, Eckstein HH, Teβarek J, Giaquinta A, van den Eynde W, Verbist J, Ahl-Gravsen J. ZILVERPASS Study: ZILVER PTX Stent vs. Bypass Surgery in Femoropopliteal Lesions, 3 year results and economic analysis. THE JOURNAL OF CARDIOVASCULAR SURGERY 2023:S0021-9509.23.12607-3. [PMID: 37162238 DOI: 10.23736/s0021-9509.23.12607-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
BACKGROUND To report the 3-year safety and effectiveness results of a multicenter, prospective, randomized controlled trial comparing the ZILVER PTX paclitaxel-eluting stent to surgical bypass and to conduct a health economic analysis up to 3-year follow-up of the two treatment modalities. METHODS This is a study in symptomatic TransAtlantic Inter-Society Consensus (TASC) C and D femoropopliteal lesions comparing endovascular ZILVER PTX stenting vs. surgical bypass surgery using a prosthetic graft (ClinicalTrials.gov identifier NCT01952457). Between October 2013 and July 2017, 220 patients (mean age 68.6±10.5 years; 159 men) were enrolled and randomized to the ZILVER PTX treatment group (113, 51.40%) or the bypass treatment group (107, 48.60%). One of the secondary outcomes was primary patency at 3-year, defined as no evidence of binary restenosis or occlusion within the target lesion or bypass graft based on a duplex ultrasound peak systolic velocity ratio <2.4 and no clinically-driven target lesion revascularization (TLR) in endovascular cases or reintervention to restore flow in the bypass. An economic analysis was conducted to analyze the cost differences between ZILVER PTX and bypass, which shows the perspective of the public authority/organization that pays for healthcare in the two countries (payor), Germany and USA. RESULTS The 3-year primary patency rate was 53.30% (95% CI 61.40% to 45.20%) for the ZILVER PTX group vs. 58.20% (95% CI 67.10% to 49.30%) for the bypass arm (P=0.9721). Freedom from TLR at 3-year was 62.80% (95% CI 72.60% to 53%) for the ZILVER PTX group vs. 65.30% (95% CI 75.40% to 55.20%) for the bypass group (P=0.635). There was also no significant difference (P=0.358) in survival rate at 3-year between the ZILVER PTX group 78.50%, (95% CI to 87.70% to 69.30%) and the bypass group 87.40% (95% CI 97.6% to 77.2%). None of the deaths was categorized as related to the procedure or device. The economic analysis, taking into account procedural-, hospitalization- and reintervention costs, showed a clear cost-benefit for Zilver PTX in both investigated countries up to 3-year follow-up: Germany (Bypass €9446 per patient versus ZILVER PTX €5755) and USA (Bypass $26,373 per patient versus ZILVER PTX $19,186). CONCLUSIONS The non-inferior safety and effectiveness results of the ZILVER PTX stent were associated with lower costs for the payer and confirmed that ZILVER PTX stent treatment can be considered as a valid alternative for bypass surgery in long and complex femoropopliteal lesions.
Collapse
|
6
|
Franklin RN, Timi JRR, Baumgardt G, Bortoluzzi C, Galego G, Oderich GS, Silveira PG. Laboratory "In-vitro" Evaluation of the Parallel Stent Graft Association for the Iliac Sandwich Technique. Cardiovasc Intervent Radiol 2022; 45:1377-1384. [PMID: 35778578 DOI: 10.1007/s00270-022-03182-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Accepted: 05/11/2022] [Indexed: 11/02/2022]
Abstract
OBJECTIVES The Iliac Sandwich is an off-label technique that uses parallel stent grafts to treat aortoiliac aneurysms. The purpose of this experimental study is to evaluate the conformability and juxtaposition of stent grafts combinations used in this technique through in-vitro mechanical evaluation, computed tomography (CT) analyses, and a controlled pulsatile flow system. METHODS The combinations of two Viabahn® ("V-V") or Viabahn® and Excluder® iliac extension ("V-E") were analysed using CT imaging with measurement of the gutter area by two independent analysts before and after balloon angioplasty. In a second phase, the parallel stent combinations were also evaluated using CT imaging after being implanted in the aortic aneurysm model with a pulsatile flow system with controlled temperature, viscosity, and density. RESULTS The "V-E" group had a better conformability when compared to the "V-V" group, ensuring smaller gutter areas (0.0064 cm2 ± 0.01 vs. 0.0228 cm2 ± 0.03, p < 0.001). Post dilatation with two non-compliant balloons resulted in enlargement of the gutter area (Area A, p 0.065; Area B, p 0.071). Conversely, post dilatation with a non-compliant balloon for the internal iliac component and a compliant balloon for the external iliac device reduced the gutter area (Area A, p 0.008; Area B, p 0.010). CONCLUSION The combination of Viabahn® and Excluder® iliac extension device ("V-E") had a smaller gutter area compared to two Viabahn® parallel stents for the Iliac Sandwich Technique. Post dilatation using a non-compliant balloon for the internal iliac device and a compliant balloon for the external iliac provided superior conformability and juxtaposition.
Collapse
|
7
|
Ferreira MB, Galego GDN, Nazário NO, Franklin RN, Silveira PG, Bortoluzzi CT, Ishikawa D, Wolf F. Use of 1,470 nm laser for treatment of superficial venous insufficiency. J Vasc Bras 2021; 20:e20200244. [PMID: 34290757 PMCID: PMC8276655 DOI: 10.1590/1677-5449.200244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2020] [Accepted: 04/12/2021] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND There are several ways to treat varicose veins of the lower limbs, among which use of 1470nm diode lasers stands out. This technique can be used to treat patients in outpatient settings, with early return to work, good esthetic results, and low rates of complications. However, variables such as the laser wavelength, the power administered in each area, the type of fiber, and the linear intravenous energy density (LEED) are still extensively discussed. OBJECTIVES To analyze the results of superficial venous insufficiency treatment with a 1470nm diode laser. METHODS Retrospective study conducted at a private clinic in a private hospital in Florianopolis, based on a database collected prospectively. The sample comprised 287 patients who underwent surgery to treat superficial venous insufficiency with 1470nm diode laser, from January 2016 to December 2018, totaling 358 great saphenous veins (GSVs) and 84 small saphenous veins (SSVs) treated. RESULTS The total occlusion rates after 12 months of surgery were 94.4% in the GSVs, with an average LEED of 45.90 J/cm, and 96.4% in the SSVs, with an average LEED of 44.07 J/cm. CONCLUSIONS During the follow-up period, the 1470nm diode laser proved to be a safe treatment, with great efficacy and low rates of complications (pain, edema, bruising, deep vein thrombosis, and endothermal heat-induced thrombosis - EHIT).
Collapse
|
8
|
Dalbosco M, Roesler CRDM, Silveira PG, Fancello EA. Numerical study on the effect of stent shape on suture forces in stent-grafts. J Mech Behav Biomed Mater 2020; 110:103852. [PMID: 32957178 DOI: 10.1016/j.jmbbm.2020.103852] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Revised: 04/06/2020] [Accepted: 05/05/2020] [Indexed: 10/24/2022]
Abstract
Second-generation stent-grafts (SGs) have addressed many of the mechanical problems reported for first-generation endoprostheses, such as graft tear and stent rupture; however, suture wear and detachment due to pulsatile fatigue remains an issue. Numerical studies on the mechanical behavior of these endoprostheses usually model the attachment between stents and graft as a continuous ''tie'' constraint, which does not provide information on the mechanical loads acting on individual sutures. This paper presents a suitable approach for Finite Element (FE) simulations of SGs which allows for a qualitative evaluation of the loads acting on sutures. Attachment between stents and graft is modeled as rigid beams at discrete locations of the endoprostheses, and the reaction forces on the beams are analyzed. This modeling strategy is employed for four different SG models (two Z-stented commercial models and two circular-stented models) subjected to a severe 180° U-bend, followed by intraluminal pressurization. Results show that, for all models, the majority of sutures is experiencing fluctuating forces within a cardiac cycle (between 80 and 120 mmHg), which points to pulsatile fatigue as potential failure mode. In addition, the highest loads are concentrated in kinks and, for Z-stented models, at the apexes of stents. Moreover, suture loads for circular-stented models are lower than for Z-stented models, indicating better resistance to suture detachment. All these observations are in line with experimental results published in the literature, and, therefore, the procedure herein proposed may serve as a valuable tool in the development of new SG models with better suture resistance to pulsatile wear and fatigue.
Collapse
|
9
|
Bosiers M, Setacci C, De Donato G, Torsello G, Silveira PG, Deloose K, Scheinert D, Veroux P, Hendriks J, Maene L, Keirse K, Navarro T, Callaert J, Eckstein HH, Teβarek J, Giaquinta A, Wauters J. ZILVERPASS Study: ZILVER PTX Stent vs Bypass Surgery in Femoropopliteal Lesions. J Endovasc Ther 2020; 27:287-295. [DOI: 10.1177/1526602820902014] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Purpose: To report the 12-month results of a multicenter, prospective, randomized controlled trial to determine if the ZILVER PTX paclitaxel-eluting stent was noninferior in terms of safety and efficacy compared with surgical bypass. Materials and Methods: This is a study in symptomatic TransAtlantic Inter-Society Consensus (TASC) C and D femoropopliteal lesions comparing endovascular ZILVER PTX stenting vs surgical bypass surgery using a prosthetic graft ( ClinicalTrials.gov identifier NCT01952457). Between October 2013 and July 2017, 220 patients (mean age 68.6±10.5 years; 159 men) were enrolled and randomized to the ZILVER PTX treatment group (113, 51.4%) or the bypass treatment group (107, 48.6%). Most of the lesions were occlusions (208, 94.5%); the mean lesion length was 247.1±69.3 mm. The primary outcome measure was primary patency at 12 months, defined as no evidence of binary restenosis or occlusion within the target lesion or bypass graft based on a duplex-derived peak systolic velocity ratio <2.4 and no clinically-driven target lesion revascularization (TLR) in endovascular cases or reintervention to restore flow in the bypass. Results: The estimated 12-month primary patency rate was 74.5% (95% CI 66.3% to 82.7%) for the ZILVER PTX group vs 72.5% (95% CI 63.7% to 81.3%) for the bypass arm (p=0.998). Freedom from TLR at 12 months was 80.9% (95% CI 73.3% to 88.5%) for the ZILVER PTX group vs 76.2% (95% CI 68.0% to 84.4%) for the bypass group (p=0.471). The 30-day complication rate was significantly lower in the ZILVER PTX group (4.4% vs 11.3%, p=0.004). Also, procedure time and hospital stay were significantly shorter in the ZILVER PTX group (p<0.001 for both). Conclusion: With noninferior patency results, a lower complication rate, and shorter procedures and hospital stays, paclitaxel-eluting stenting might become a recommended treatment for long TASC C and D femoropopliteal lesions.
Collapse
|
10
|
Galego GDN, Silveira PG, Broering JJ, Eli EDS, Corbellini MP, de Oliveira AAM. In vivo evaluation of a new vena cava filter. J Vasc Bras 2016; 15:99-105. [PMID: 29930573 PMCID: PMC5829702 DOI: 10.1590/1677-5449.006915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Background Pulmonary embolism is an important cause of cardiovascular death. Inferior vena cava filters have been shown to be effective for prevention of this condition. Objectives To determine the safety, performance and efficacy of a new inferior vena cava filter in an ovine model. Methods BKone1 filters are self-centering with over-the-wire deployment, have three filtering regions and are made from nickel-titanium alloy. Eight of these filters were implanted in 8 sheep. The sheep were divided into 4 groups of two animals (A and B) and the number of clots injected differed by group. Two clots were injected in group 2, four in group 3, eight in group 4 and zero clots in group 1. A animals underwent euthanasia soon after the procedure and B animals were observed for 30 days and then euthanized after a control cavography. All inferior vena cavas were processed for histological examination. Clots were prepared in a metal mold, sectioned and then radiopaque markers were inserted. Clot capture was analyzed by identifying the radiopaque marker on fluoroscopy. Results No clot migration was observed during follow-up. Control cavographies showed patent inferior vena cavas. Pathological examination indicated little inflammatory tissue response. All clots were captured in the condition with 2 clots, only one clot was missed in the group injected with 4 clots and in the condition of 8 clots, they were partly captured. Conclusions The filters were deployed safely. There was a reduction in efficacy as the number of blood clots increased.
Collapse
|
11
|
Galego GDN, Silveira PG, Bortoluzzi CT, Franklin RN, Ronchi TM. Síndrome da Congestão Venosa Pélvica e resultados do tratamento endovascular: série de casos. J Vasc Bras 2015. [DOI: 10.1590/1677-5449.0085] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
ResumoA Síndrome da Congestão Venosa Pélvica (SCVP) é uma causa de dor pélvica crônica, que afeta principalmente mulheres multíparas em idade reprodutiva. Para o tratamento desta síndrome, a embolização de varizes pélvicas tem demonstrado excelentes resultados. Relatamos uma série inicial de pacientes submetidas a tratamento com embolização de varizes pélvicas e os respectivos resultados de acompanhamento pós-operatório. São apresentados dados clínicos, detalhes do procedimento e resultados do acompanhamento e de exames de imagem de seis pacientes. Dentre estas pacientes, o sucesso técnico foi de 100% e não houve relato de complicações trans ou pós-operatórias graves. Em todos os casos, pôde-se observar alívio dos sintomas e melhora nos resultados de exames de imagens no acompanhamento de curto prazo. Os resultados nesta pequena série de casos indicam que a embolização é um tratamento seguro e efetivo para a SCVP.
Collapse
|
12
|
Galego GDN, Lima GBB, Franklin RN, Bortoluzzi CT, Silveira PG. Outcome of 1470nm laser diode ablation for superficial venous insufficiency. J Vasc Bras 2015. [DOI: 10.1590/1677-5449.0073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
BACKGROUND: Endovenous laser ablation is a minimally invasive procedure that can be used to treat superficial venous insufficiency. We believe that using a longer wavelength will reduce the frequency of the most common adverse effects associated with the use of shorter wavelengths.OBJECTIVES: To report the results of an initial series of patients with chronic superficial venous insufficiency treated using a 1470 nanometer diode laser and to compare results using linear and radial laser fibers.METHODS: We conducted an observational cohort study. Seventy-four patients, for whom at least two postoperative Doppler ultrasonography scans were available, were recruited with a total of 121 saphenous veins treated (92 great and 29 small saphenous veins). There were 57 patients in Group A (treated with the linear fiber) and 17 in Group B (radial fiber). Follow-up ideally comprised clinical consultation and Doppler ultrasonography at 1 month, 6 months and 12 months after the procedure. Success was defined as total occlusion of the venous segment that had been treated.RESULTS: Success rates at mean follow-up of 13.4 months (range 7 - 27) were 83% for great saphenous veins and 89% for small saphenous veins. Patients treated with the radial fiber required less energy to achieve occlusion of the small saphenous vein and exhibited fewer adverse reactions, with statistical significance.CONCLUSIONS: Treatment of great and small saphenous vein insufficiency using the 1470 nm diode laser is safe and effective. The radial fiber was associated with fewer intercurrent conditions than the linear fiber, although success rates were similar.
Collapse
|
13
|
Silveira PG, Cunha JRF, Barbosa Lima GB, Franklin RN, Bortoluzzi CT, Galego GDN. Endovascular Treatment of Ruptured Abdominal Aortic Aneurysm with Aortocaval Fistula Based on Aortic and Inferior Vena Cava Stent-Graft Placement. Ann Vasc Surg 2014; 28:1933.e1-5. [DOI: 10.1016/j.avsg.2014.06.073] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2014] [Revised: 06/05/2014] [Accepted: 06/19/2014] [Indexed: 11/16/2022]
|
14
|
Silveira PG, Franklin RN, Cunha JRF, Neves TT, Nascimento GG, Bortoluzzi CT. Total endovascular repair of aberrant left subclavian artery with Kommerell's diverticulum using a customized branched device. J Vasc Surg 2013; 57:1123-5. [PMID: 23312832 DOI: 10.1016/j.jvs.2012.10.008] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2012] [Revised: 09/18/2012] [Accepted: 10/06/2012] [Indexed: 11/17/2022]
Abstract
We describe a case of Kommerell's diverticulum involving the distal portion of a right-sided aortic arch and the origin of an aberrant left subclavian artery (LSA). The patient underwent a total endovascular repair with the use of a modified Valiant endograft (Medtronic, Minneapolis, Minn) to which a branch was attached to keep LSA patency. Postoperative computed tomography showed complete exclusion of the lesion, without endoleaks. The use of "customized off-label" devices to treat special conditions was feasible in this case, keeping patency of the LSA without risk of arm claudication or the requirement for a complementary surgical bypass.
Collapse
|
15
|
Silveira PG, Galego GN, Bortoluzzi CT, Franklin RN. RE: "Branched grafts for thoracoabdominal aneurysms: off-label use of FDA-approved devices". J Endovasc Ther 2012; 19:130. [PMID: 22313215 DOI: 10.1583/11-3773.1] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
16
|
Böckler D, Fitridge R, Wolf Y, Hayes P, Silveira PG, Numan F, Riambau V. Rationale and design of the Endurant Stent Graft Natural Selection Global Postmarket Registry (ENGAGE): interim analysis at 30 days of the first 180 patients enrolled. THE JOURNAL OF CARDIOVASCULAR SURGERY 2010; 51:481-491. [PMID: 20671632] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
AIM The Endurant Stent Graft Natural Selection Global Postmarket Registry (ENGAGE) is a long-term 1200-patient multicenter prospective study initiated to augment the knowledge base (poolable and comparable) about endovascular aortic repair (EVAR) in a real-world population implanted with a single latest-generation stent graft system (Endurant). With enrollment ongoing at 80 high-volume sites, the registry has limited inclusion/exclusion criteria or procedural specification. Technical and clinical data will be reported through 5 years. METHODS An interim analysis was performed on investigator-reported data for the first 180 patients enrolled. These patients were asymptomatic elderly males (92.1%) with considerable comorbidities. For 47.3% of the patients, the American Society of Anesthesiologists risk class was either III or IV. The Endurant stent graft was successfully deployed in 99.4% of patients for elective treatment of abdominal aortic aneurysm. RESULTS Through 30 days, the rate of all-cause mortality was 1.7% (N=3), with all 3 deaths classified as procedure-related but not device-related. The rate of secondary endovascular procedures was 1.1%, and the rate of conversion to open repair was 0.6%. At postprocedure and at 30-day follow-up, there were no type I or type III endoleaks and no instances of stent graft kinking, thrombosis, or occlusion. ENGAGE represents the largest real-world registry for any single EVAR stent graft. CONCLUSION The interim results through 30 days of the first 180 patients enrolled are promising. Longer-term follow-up for more patients will be reported.
Collapse
|
17
|
Silveira PG, Miller CWT, Mendes RF, Galego GN. Correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter during endovascular repair of abdominal aortic aneurysm. Clinics (Sao Paulo) 2008; 63:59-66. [PMID: 18297208 PMCID: PMC2664183 DOI: 10.1590/s1807-59322008000100011] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2007] [Accepted: 11/07/2007] [Indexed: 11/25/2022] Open
Abstract
PURPOSE To establish a correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter placed in the same aneurysm sac before and after its exclusion by an endoprosthesis. METHODS Patients who underwent endovascular abdominal aortic aneurysm repair and received an EndoSure wireless pressure sensor implant between March 19 and December 11, 2004 were enrolled in the study. Simultaneous readings of systolic, diastolic, mean, and pulse pressure within the aneurysm sac were obtained from the catheter and the sensor, both before and after sac exclusion by the endoprosthesis (Readings 1 and 2, respectively). Intrasac pressure measurements were compared using Pearson's correlation and Student's t test. Statistical significance was set at p<0.05. RESULTS Twenty-five patients had the pressure sensor implanted, with simultaneous readings (i.e., recorded by both devices) obtained in 19 patients for Reading 1 and in 10 patients for Reading 2. There was a statistically significant correlation for all pressure variables during both readings, with p<0.01 for all except the pulse pressure in Reading 1 (p<0.05). Statistical significance of pressure variations before and after abdominal aortic aneurysm exclusion was coincident between the sensor and catheter for diastolic (p>0.05), mean (p>0.05), and pulse (p<0.01) pressures; the sole disagreement was observed for systolic pressure, which varied, on average, 31.23 mmHg by the catheter (p<0.05) and 22 mmHg (p>0.05) by the sensor. CONCLUSION The excellent agreement between intrasac pressure readings recorded by the catheter and the sensor justifies use of the latter for detection of post-exclusion abdominal aortic aneurysm pressurization.
Collapse
|
18
|
Ohki T, Ouriel K, Silveira PG, Katzen B, White R, Criado F, Diethrich E. Initial results of wireless pressure sensing for endovascular aneurysm repair: The APEX Trial—Acute Pressure Measurement to Confirm Aneurysm Sac EXclusion. J Vasc Surg 2007; 45:236-42. [PMID: 17263995 DOI: 10.1016/j.jvs.2006.09.060] [Citation(s) in RCA: 97] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2006] [Accepted: 09/30/2006] [Indexed: 11/26/2022]
Abstract
OBJECTIVE Complete exclusion and depressurization of the aneurysm sac is the prime goal of endovascular repair (EVAR) of abdominal aortic aneurysms. Thus, any EVAR that results in a type I or III endoleak has been classified as a technical failure. The current method to detect endoleaks uses intraoperative aortography. However, aortography is limited by its subjective nature, inability to quantify the significance of the endoleak, and artifacts such as bowel gas that may mimic an endoleak. In addition, repetitive contrast injection may impair renal function. To increase the efficacy and safety of intraoperative endoleak detection, a wireless pressure-monitoring system has been developed and tested in the clinical setting. METHODS The APEX trial (Acute Pressure Measurement to Confirm Aneurysm Sac EXclusion) is a prospective, multicenter/international trial sponsored by CardioMEMS to evaluate the safety and efficacy of the EndoSure wireless pressure sensor for EVAR. The 30 x 5 x 1.5-mm sensor contains no battery and is powered externally with radiofrequency energy. The sensors are extremely stable, operate over the full physiologic range of pressures, and have a resolution of 1 mm Hg. A total of 90 patients were enrolled at 12 sites, 76 of whom were eligible for analysis. The sensor was implanted via the contralateral femoral artery at the time of EVAR. The sac pulse pressure was measured with both an angiographic catheter and the sensor after deployment of the main endograft but before the deployment of the contralateral limb (type I endoleak equivalent). Sac pressure was again measured with the sensor after deployment of the contralateral limb and completion of the EVAR. Data were collected in a prospective manner. RESULTS In all of the eligible patients (n = 76), the initial sensor pressure measurement agreed closely with the angiographic catheter pressure measurement of the type I endoleak equivalent. At the completion of the procedure, there was agreement between the sensor measurement and angiography regarding the presence or absence of a type I or III endoleak in 92.1% (n = 70) of the measurements. Overall, the sensitivity was 0.94 and the specificity was 0.80 for detecting type I or III endoleaks. Final pulse pressures decreased significantly compared with baseline measurements. CONCLUSIONS Implantation of the wireless pressure sensor is safe, and remote aneurysm sac pressure sensing is feasible. It was a valuable guide in evaluating the completeness of the EVAR procedure. Long-term study will be needed to prove its efficacy for postoperative surveillance.
Collapse
|
19
|
Silveira PG, Galego GDN, d’Acampora AJ, Bittencourt A, Kestering D, Philippi FF, Rizzatti J. Estudo experimental comparativo da eficácia antitrombótica da heparina convencional e da heparina de baixo peso molecular. Acta Cir Bras 2001. [DOI: 10.1590/s0102-86502001000400003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/03/2023] Open
Abstract
Em estudo randomizado e cego comparou-se a eficácia antitrombótica (redução do peso do trombo) de duas heparinas; uma de baixo peso molecular (HBPM) e outra não fracionada - heparina convencional (HC). Foram utilizados dois procedimentos de trombose venosa experimental: no grupo I a trombose venosa foi induzida injetando-se oleato de etanolamina na veia jugular de 30 coelhos e glicose a 50% em mais 30, todos da raça New Zealand. No Grupo II a trombose venosa foi induzida por estase mediante a ligadura da veia cava de 30 ratos da raça Wistar. Não se encontrou diferenças estatisticamente significantes com relação à redução do peso do trombo em ambos os grupos. Também concluiu-se que a eficácia antitrombótica das drogas estudadas não variou conforme o tipo de estímulo indutor da trombose nos modelos testados, e que o oleato de etanolamina induziu de forma mais significante a formação de trombos no grupo I.
Collapse
|
20
|
Bertoncini RL, Silveira PG, Ceola L, Vieira GN, Luz NW. [Vascular complications in intravenous drug addicts]. Rev Assoc Med Bras (1992) 1992; 38:204-8. [PMID: 1340377] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
Twenty patients with complications of drug addiction were admitted to the Department of Vascular Surgery of the Santa Catarina University Hospital, from January 1986 to September 1990. Most of these patients were male, aged between 20 and 35 years. The most common drug used was propoxiphene, followed by cocaine. Swelling, ulcers and pain in the inferior extremities were the most common signs and symptoms. Six patients presented deep venous thrombosis, four had acute lymphangitis, all of them in the lower limbs. Five patients had acute arterial occlusions, one presented common femoral artery mycotic aneurysm and another had a false aneurysm of the superficial femoral artery. Venous and lymphatic complications were clinically treated with antibiotics, heparin and local care. Six patients were submitted to surgical procedures. One was treated by aneurysmectomy and vascular reconstruction, another with aneurysmectomy and arterial ligation. On one patient forearm fasciotomy was performed. Two amputations and one drainage of abscess were carried out.
Collapse
|