1
|
Platelet extracellular vesicles are superior to cardiac troponin to diagnose acute coronary syndrome with short symptom duration: LEMONADE trial. Eur Heart J 2022. [DOI: 10.1093/eurheartj/ehac544.1284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Background
Acute coronary syndrome (ACS), which comprises acute myocardial infarction (AMI) and unstable angina pectoris (UAP), is one of the main causes of mortality worldwide. Cardiac troponin is the gold standard to diagnose AMI. Troponin has two main disadvantages: it is negative in patients with UAP but positive in other diseases. During ACS, activated platelets release extracellular vesicles (EVs), which promote coagulation and associate with fibrin, and contribute to thrombus formation. We hypothesized that the concentration and composition of circulating platelet EVs (1) change in blood of patients with ACS compared to patients with other causes of chest pain, and (2) thereby allow earlier diagnosis of ACS than cardiac troponin.
Purpose
We aimed to determine the diagnostic value of circulating platelet EVs as novel early biomarkers of developing ACS.
Methods
We conducted a prospective, multicentre trial enrolling 105 patients who presented to the emergency department with suspected ACS. Blood was collected at admission to measure the concentration of EVs and cardiac troponin. Flow cytometry (Apogee A60-Micro) was used to determine plasma concentrations of platelet EVs exposing P-selectin (CD61+/CD62p+) and fibrin (CD61+/fibrin+).
Results
Plasma concentrations of platelet EVs exposing fibrin was lower in patients with ACS, compared to patients with other causes of chest pain (p=0.023) and lower in patients with an occlusive thrombus compared to non-occlusive plaque (p=0.015). Fibrin exposing-EVs were independent predictors of ACS (OR 8.2, CI 1.3–16.4) in multivariate analysis, allowing to diagnose ACS with 75% sensitivity and 72% specificity. Among patients with pain onset less than 2 hours before presentation, fibrin-exposing EVs had substantially better diagnostic performance than troponin (area under the ROC curve 0.90 vs. 0.74, respectively). Regarding other causes of chest pain, fibrin-exposing EVs were the lowest in patients with ACS, higher in patients with other cardiological causes of chest pain, and the highest in patients with non-cardiological causes of chest pain (p=0.036).
Conclusions
Circulating fibrin-exposing EVs are early biomarkers of developing ACS, superior to cardiac troponin in patients with pain onset less than 2 hours before presentation. Incorporation of EV measurements into the ACS diagnostic algorithm might revolutionise thrombotic risk stratification in the emergency setting.
Funding Acknowledgement
Type of funding sources: Public grant(s) – National budget only. Main funding source(s): Specialised Research Fellowship, “Club 30” of the Polish Society of Cardiology
Collapse
|
2
|
Leukocyte extracellular vesicles as the first biomarkers to predict outcomes in patients undergoing percutaneous aortic valve replacement. Eur Heart J 2022. [DOI: 10.1093/eurheartj/ehac544.1626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Abstract
Background
Transcatheter aortic valve implantation (TAVI) is a novel treatment for aortic stenosis (AS), associated with better outcomes than surgical aortic valve replacement in high-risk patients. However, up to 29% of patients annually experience major adverse cardiac and cerebrovascular events (MACCE) after TAVI. MACCE are mostly caused by atherothrombosis, i.e. formation of platelet aggregates (thrombi) on ruptured atherosclerotic plaques. Because platelets release extracellular vesicles (EVs) during thrombus formation, we hypothesized that EVs are a biomarker to predict MACCE after TAVI.
Methods
This was a multicentre, prospective clinical study. Venous blood was collected 1 day before TAVI and at hospital discharge (n=57, mean age 79.9+6.4 years, 49% male). Flow cytometry (Apogee A60-Micro) was used to determine concentrations of plasma EVs labelled with markers for endothelial cells (CD146), leukocytes (CD45), platelets and megakaryocytes (CD61) and activated platelets (CD62p). Analysis of flow cytometry data files was fully automated. Rosetta Calibration (Exometry) and Flow-SR were used for diameter and refractive index determination. Wilcoxon signed rank test was used to compare EV concentrations before and after TAVI. The predictive value of EVs for MACCE and the cut-offs were calculated using a receiver operating characteristic curve. Logistic regression model incorporating EV concentrations and clinical characteristics was used to determine the best model for MACCE prediction.
Results
Concentrations of EVs from activated platelets increased, whereas from leukocytes decreased after TAVI, compared to the measurement before (p=0.06, p=0.04, respectively). Among 55 patients discharged from the hospital, 14 patients experienced MACCE (25%) during the median 15 months of observation. Increased baseline concentration of leukocyte EVs and male gender were the only independent predictors of MACCE in multivariable analysis (OR 4.01, 95% CI 0.77–23.77, p=0.04 for leukocyte EVs; OR 6.84, 95% CI 1.41–33.17, p=0.03 for male gender).
Conclusions
We identified increased concentrations of leukocyte EVs as new candidate biomarkers to predict MACCE after TAVI. Leukocyte EVs could be used to augment risk stratification in this patient cohort. The next step is to validate the clinical applicability of EVs to predict post-TAVI MACCE in a large-scale clinical trial.
Funding Acknowledgement
Type of funding sources: Public grant(s) – National budget only. Main funding source(s): Young Investigator Grant of the Polish Society of Cardiology
Collapse
|
3
|
Cancer-ID: Toward Identification of Cancer by Tumor-Derived Extracellular Vesicles in Blood. Front Oncol 2020; 10:608. [PMID: 32582525 PMCID: PMC7287034 DOI: 10.3389/fonc.2020.00608] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2020] [Accepted: 04/02/2020] [Indexed: 12/19/2022] Open
Abstract
Extracellular vesicles (EVs) have great potential as biomarkers since their composition and concentration in biofluids are disease state dependent and their cargo can contain disease-related information. Large tumor-derived EVs (tdEVs, >1 μm) in blood from cancer patients are associated with poor outcome, and changes in their number can be used to monitor therapy effectiveness. Whereas, small tumor-derived EVs (<1 μm) are likely to outnumber their larger counterparts, thereby offering better statistical significance, identification and quantification of small tdEVs are more challenging. In the blood of cancer patients, a subpopulation of EVs originate from tumor cells, but these EVs are outnumbered by non-EV particles and EVs from other origin. In the Dutch NWO Perspectief Cancer-ID program, we developed and evaluated detection and characterization techniques to distinguish EVs from non-EV particles and other EVs. Despite low signal amplitudes, we identified characteristics of these small tdEVs that may enable the enumeration of small tdEVs and extract relevant information. The insights obtained from Cancer-ID can help to explore the full potential of tdEVs in the clinic.
Collapse
|
4
|
Response to letter to the editor. J Extracell Vesicles 2019. [DOI: 10.1080/20013078.2019.1648997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] Open
|
5
|
Refractive index to evaluate staining specificity of extracellular vesicles by flow cytometry. J Extracell Vesicles 2019; 8:1643671. [PMID: 31489142 PMCID: PMC6713200 DOI: 10.1080/20013078.2019.1643671] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Revised: 06/06/2019] [Accepted: 07/11/2019] [Indexed: 12/12/2022] Open
Abstract
Extracellular vesicles (EVs) in plasma are commonly identified by staining with antibodies and generic dyes, but the specificity of antibodies and dyes to stain EVs is often unknown. Previously, we showed that platelet-depleted platelet concentrate contains two populations of particles >200 nm, one population with a refractive index (RI) < 1.42 that included the majority of EVs, and a second population with an RI > 1.42, which was thought to include lipoproteins. In this study, we investigated whether EVs can be distinguished from lipoproteins by the RI and whether the RI can be used to determine the specificity of antibodies and generic dyes used to stain plasma EVs. EVs and lipoproteins present in platelet-depleted platelet concentrate were separated by density gradient centrifugation. The density fractions were analyzed by Western blot and transmission electron microscopy, the RI of particles was determined by Flow-SR. The RI was used to evaluate the staining specificity of an antibody against platelet glycoprotein IIIa (CD61) and the commonly used generic dyes calcein AM, calcein violet, di-8-ANEPPS, and lactadherin in plasma. After density gradient centrifugation, EV-enriched fractions (1.12 to 1.07 g/mL) contained the highest concentration of particles with an RI < 1.42, and the lipoprotein-enriched fractions (1.04 to 1.03 g/mL) contained the highest concentration of particles with an RI > 1.42. Application of the RI showed that CD61-APC had the highest staining specificity for EVs, followed by lactadherin and calcein violet. Di-8-ANEPPS stained mainly lipoproteins and calcein AM stained neither lipoproteins nor EVs. Taken together, the RI can be used to distinguish EVs and lipoproteins, and thus allows evaluation of the specificity of antibodies and generic dyes to stain EVs.
Collapse
|
6
|
Quality of extracellular vesicle images by transmission electron microscopy is operator and protocol dependent. J Extracell Vesicles 2019; 8:1555419. [PMID: 30651939 PMCID: PMC6327933 DOI: 10.1080/20013078.2018.1555419] [Citation(s) in RCA: 123] [Impact Index Per Article: 24.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2018] [Revised: 11/02/2018] [Accepted: 11/21/2018] [Indexed: 01/08/2023] Open
Abstract
Transmission electron microscopy (TEM) has nanometre resolution and can be used to distinguish single extracellular vesicles (EVs) from non-EV particles. TEM images of EVs are a result of operator image selection. To which extent operator image selection reflects the overall sample quality, and to which extent the images are comparable and reproducible, is unclear. In a first attempt to improve the comparability and reproducibility of TEM to visualise EVs, we compared operator image selection to images taken at predefined locations from the same grids, using four EV TEM preparation protocols, a single EV-containing sample and a single TEM instrument. Operator image selection leads to high-quality images that are more similar between the protocols. In contrast, images taken at predefined locations reveal differences between the protocols, for example in number of EVs per image and background quality. From the evaluated protocols, for only one protocol the operator image selection is comparable to the TEM images taken at predefined locations. Taken together, operator image selection can be used to demonstrate the presence of EVs in a sample, but seem less suitable to demonstrate the quality of a sample. Because images taken at predefined locations reflect the overall quality of the EV-containing sample rather than the presence of EVs alone, this is a first step to improve the comparability and reproducibility of TEM for monitoring the quality of EV-containing samples.
Collapse
|
7
|
Hollow organosilica beads as reference particles for optical detection of extracellular vesicles. J Thromb Haemost 2018; 16:S1538-7836(22)02214-0. [PMID: 29877049 DOI: 10.1111/jth.14193] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2017] [Indexed: 11/30/2022]
Abstract
Essentials Standardization of extracellular vesicle (EV) measurements by flow cytometry needs improvement. Hollow organosilica beads were prepared, characterized, and tested as reference particles. Light scattering properties of hollow beads resemble that of platelet-derived EVs. Hollow beads are ideal reference particles to standardize scatter flow cytometry research on EVs. SUMMARY Background The concentration of extracellular vesicles (EVs) in body fluids is a promising biomarker for disease, and flow cytometry remains the clinically most applicable method to identify the cellular origin of single EVs in suspension. To compare concentration measurements of EVs between flow cytometers, solid polystyrene reference beads and EVs were distributed in the first ISTH-organized interlaboratory comparison studies. The beads were used to set size gates based on light scatter, and the concentration of EVs was measured within the size gates. However, polystyrene beads lead to false size determination of EVs, owing to the mismatch in refractive index between beads and EVs. Moreover, polystyrene beads gate different EV sizes on different flow cytometers. Objective To prepare, characterize and test hollow organosilica beads (HOBs) as reference beads to set EV size gates in flow cytometry investigations. Methods HOBs were prepared with a hard template sol-gel method, and extensively characterized for morphology, size, and colloidal stability. The applicability of HOBs as reference particles was investigated by flow cytometry with HOBs and platelet-derived EVs. Results HOBs proved to be monodisperse with a homogeneous shell thickness. Two-angle light-scattering measurements by flow cytometry confirmed that HOBs have light-scattering properties similar to those of platelet-derived EVs. Conclusions Because the structure and light-scattering properties HOBs resemble those of EVs, HOBs with a given size will gate EVs of the same size. Therefore, HOBs are ideal reference beads with which to standardize optical measurements of the EV concentration within a predefined size range.
Collapse
|
8
|
Standardization of extracellular vesicle measurements by flow cytometry through vesicle diameter approximation. J Thromb Haemost 2018; 16:1236-1245. [PMID: 29575716 DOI: 10.1111/jth.14009] [Citation(s) in RCA: 113] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2017] [Indexed: 12/12/2022]
Abstract
Essentials Platelet extracellular vesicles (EVs) concentrations measured by flow cytometers are incomparable. A model is applied to convert ambiguous scatter units to EV diameter in nanometer. Most included flow cytometers lack the sensitivity to detect EVs of 600 nm and smaller. The model outperforms polystyrene beads for comparability of platelet EV concentrations. SUMMARY Background Detection of extracellular vesicles (EVs) by flow cytometry has poor interlaboratory comparability, owing to differences in flow cytometer (FCM) sensitivity. Previous workshops distributed polystyrene beads to set a scatter-based diameter gate in order to improve the comparability of EV concentration measurements. However, polystyrene beads provide limited insights into the diameter of detected EVs. Objectives To evaluate gates based on the estimated diameter of EVs instead of beads. Methods A calibration bead mixture and platelet EV samples were distributed to 33 participants. Beads and a light scattering model were used to set EV diameter gates in order to measure the concentration of CD61-phycoerythrin-positive platelet EVs. Results Of the 46 evaluated FCMs, 21 FCMs detected the 600-1200-nm EV diameter gate. The 1200-3000-nm EV diameter gate was detected by 31 FCMs, with a measured EV concentration interlaboratory variability of 81% as compared with 139% with the bead diameter gate. Part of the variation in both approaches is caused by precipitation in some of the provided platelet EV samples. Flow rate calibration proved essential because systems configured to 60 μL min-1 differed six-fold in measured flow rates between instruments. Conclusions EV diameter gates improve the interlaboratory variability as compared with previous approaches. Of the evaluated FCMs, 24% could not detect 400-nm polystyrene beads, and such instruments have limited utility for EV research. Finally, considerable differences were observed in sensitivity between optically similar instruments, indicating that maintenance and training affect the sensitivity.
Collapse
|
9
|
Extracellular vesicles from human saliva promote hemostasis by delivering coagulant tissue factor to activated platelets. J Thromb Haemost 2018; 16:1153-1163. [PMID: 29658195 DOI: 10.1111/jth.14023] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2018] [Indexed: 02/06/2023]
Abstract
Essentials Human salivary extracellular vesicles (EVs) expose coagulant tissue factor (TF). Salivary EVs expose CD24, a ligand of P-selectin. CD24 and coagulant TF co-localize on salivary EVs. TF+ /CD24+ salivary EVs bind to activated platelets and trigger coagulation. SUMMARY Background Extracellular vesicles (EVs) from human saliva expose coagulant tissue factor (TF). Whether such TF-exposing EVs contribute to hemostasis, however, is unknown. Recently, in a mice model, tumor cell-derived EVs were shown to deliver coagulant TF to activated platelets at a site of vascular injury via interaction between P-selectin glycoprotein ligand-1 (PSGL-1) and P-selectin. Objectives We hypothesized that salivary EVs may deliver coagulant TF to activated platelets via interaction with P-selectin. Methods We investigated the presence of two ligands of P-selectin on salivary EVs, PSGL-1 and CD24. Results Salivary EVs expose CD24 but PSGL-1 was not detected. Immune depletion of CD24-exposing EVs completely abolished the TF-dependent coagulant activity of cell-free saliva, showing that coagulant TF and CD24 co-localize on salivary EVs. In a whole blood perfusion model, salivary EVs accumulated at the surface of activated platelets and promoted fibrin generation, which was abolished by an inhibitory antibody against human CD24. Conclusions A subset of EVs in human saliva expose coagulant TF and CD24, a ligand of P-selectin, suggesting that such EVs may facilitate hemostasis at a site of skin injury where the wound is licked in a reflex action.
Collapse
|
10
|
Biological reference materials for extracellular vesicle studies. Eur J Pharm Sci 2017; 98:4-16. [DOI: 10.1016/j.ejps.2016.09.008] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2016] [Revised: 09/06/2016] [Accepted: 09/06/2016] [Indexed: 01/05/2023]
|
11
|
The histophysiology and pathophysiology of the peritoneum. Tissue Cell 2017; 49:95-105. [DOI: 10.1016/j.tice.2016.11.004] [Citation(s) in RCA: 95] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2016] [Revised: 11/11/2016] [Accepted: 11/11/2016] [Indexed: 12/14/2022]
|
12
|
Standardization of microparticle enumeration across different flow cytometry platforms: results of a multicenter collaborative workshop. J Thromb Haemost 2017; 15:187-193. [PMID: 27662257 PMCID: PMC5280151 DOI: 10.1111/jth.13514] [Citation(s) in RCA: 85] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2016] [Accepted: 08/26/2016] [Indexed: 12/24/2022]
Abstract
Essentials The clinical enumeration of microparticles (MPs) is hampered by a lack of standardization. A new strategy to standardize MP counts by flow cytometry was evaluated in a multicenter study. No difference was found between instruments using forward or side scatter as the trigger parameter. This study demonstrated that beads can be used as a standardization tool for MPs. Click to hear the ISTH Academy's webinar on microvesicles SUMMARY: Background Microparticles (MPs) are extracellular vesicles resulting from the budding of cellular membranes that have a high potential as emergent biomarkers; however, their clinical relevance is hampered by methodological enumeration concerns and a lack of standardization. Flow cytometry (FCM) remains the most commonly used technique with the best capability to determine the cellular origin of single MPs. However, instruments behave variably depending on which scatter parameter (forward (FSC) or side scatter (SSC)) provides the best resolution to discriminate submicron particles. To overcome this problem, a new approach, based on two sets of selected beads adapted to FSC or SSC-optimized instruments, was recently proposed to reproducibly enumerate platelet-derived MP counts among instruments with different optical systems. Objective The objective was to evaluate this strategy in an international workshop that included 44 laboratories accounting for 52 cytometers of 14 types. Methods/Results Using resolution capability and background noise level as criteria to qualify the instruments, the standardization strategy proved to be compatible with 85% (44/52) of instruments. All instruments correctly ranked the platelet MP (PMP) levels of two platelet-free plasma samples. The inter-laboratory variability of PMP counts was 37% and 28% for each sample. No difference was found between instruments using forward or side-scattered light as the relative sizing parameter. Conclusions Despite remaining limitations, this study is the first to demonstrate a real potential of bead-based strategies for standardization of MP enumeration across different FCM platforms. Additional standardization efforts are still mandatory to evaluate MPs' clinical relevance at a multicenter level.
Collapse
|
13
|
Non-polar lipids accumulate during storage of transfusion products and do not contribute to the onset of transfusion-related acute lung injury. Vox Sang 2016; 112:25-32. [DOI: 10.1111/vox.12453] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2016] [Revised: 07/27/2016] [Accepted: 09/02/2016] [Indexed: 12/23/2022]
|
14
|
Recent developments in the nomenclature, presence, isolation, detection and clinical impact of extracellular vesicles. J Thromb Haemost 2016; 14:48-56. [PMID: 26564379 DOI: 10.1111/jth.13190] [Citation(s) in RCA: 227] [Impact Index Per Article: 28.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2015] [Indexed: 02/06/2023]
Abstract
The research field of extracellular vesicles (EVs), such as microparticles and exosomes, is growing exponentially. The goal of this review is to provide an overview of recent developments relevant to the readers of the Journal of Thrombosis and Haemostasis. We will discuss nomenclature, the presence of EVs in fluids, methods of isolation and detection, and emerging clinical implications. Although research on EVs has been performed within the ISTH for over a decade, most of the recent research on EVs has been brought together by the International Society on Extracellular Vesicles (ISEV). To achieve an overview of recent developments, the information provided in this review comes not only from publications, but also from latest meetings of the ISEV (April 2015, Washington, DC, USA), the International Society on Advancement of Cytometry (June 2015, Glasgow, UK), and the ISTH (June 2015, Toronto, Canada).
Collapse
|
15
|
Low miR-19b-1-5p expression in isolated platelets after aspirin use is related to aspirin insensitivity. Int J Cardiol 2015; 203:262-3. [PMID: 26519680 DOI: 10.1016/j.ijcard.2015.10.098] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/09/2015] [Accepted: 10/13/2015] [Indexed: 12/01/2022]
|
16
|
Endogenous microparticles drive the proinflammatory host immune response in severely injured trauma patients. Crit Care 2015. [PMCID: PMC4472788 DOI: 10.1186/cc14393] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
17
|
Microparticles from red blood cell transfusion products induce a strong inflammatory host response. Crit Care 2015. [PMCID: PMC4471676 DOI: 10.1186/cc14416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
18
|
CD9-positive Mikropartikel in Follikelflüssigkeit – ein möglicher Einfluss auf das Reproduktionsgeschehen? Geburtshilfe Frauenheilkd 2014. [DOI: 10.1055/s-0034-1388010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022] Open
|
19
|
Particle size distribution of exosomes and microvesicles determined by transmission electron microscopy, flow cytometry, nanoparticle tracking analysis, and resistive pulse sensing. J Thromb Haemost 2014; 12:1182-92. [PMID: 24818656 DOI: 10.1111/jth.12602] [Citation(s) in RCA: 590] [Impact Index Per Article: 59.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2013] [Accepted: 04/25/2014] [Indexed: 11/30/2022]
Abstract
BACKGROUND Enumeration of extracellular vesicles has clinical potential as a biomarker for disease. In biological samples, the smallest and largest vesicles typically differ 25-fold in size, 300,000-fold in concentration, 20,000-fold in volume, and 10,000,000-fold in scattered light. Because of this heterogeneity, the currently employed techniques detect concentrations ranging from 10(4) to 10(12) vesicles mL(-1) . OBJECTIVES To investigate whether the large variation in the detected concentration of vesicles is caused by the minimum detectable vesicle size of five widely used techniques. METHODS The size and concentration of vesicles and reference beads were measured with transmission electron microscopy (TEM), a conventional flow cytometer, a flow cytometer dedicated to detecting submicrometer particles, nanoparticle tracking analysis (NTA), and resistive pulse sensing (RPS). RESULTS Each technique gave a different size distribution and a different concentration for the same vesicle sample. CONCLUSION Differences between the detected vesicle concentrations are primarily caused by differences between the minimum detectable vesicle sizes. The minimum detectable vesicle sizes were 70-90 nm for NTA, 70-100 nm for RPS, 150-190 nm for dedicated flow cytometry, and 270-600 nm for conventional flow cytometry. TEM could detect the smallest vesicles present, albeit after adhesion on a surface. Dedicated flow cytometry was most accurate in determining the size of reference beads, but is expected to be less accurate on vesicles, owing to heterogeneity of the refractive index of vesicles. Nevertheless, dedicated flow cytometry is relatively fast and allows multiplex fluorescence detection, making it most applicable to clinical research.
Collapse
|
20
|
Differences in platelet microRNA profiles after aspirin use are associated with differences in whole blood aggregation and might identify aspirin resistance. Eur Heart J 2013. [DOI: 10.1093/eurheartj/eht310.p4884] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
21
|
Procoagulant tissue factor-exposing vesicles in human seminal fluid. J Reprod Immunol 2013; 98:45-51. [DOI: 10.1016/j.jri.2013.02.002] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2012] [Revised: 01/21/2013] [Accepted: 02/10/2013] [Indexed: 12/18/2022]
|
22
|
Abstract
Cell-derived or extracellular vesicles, including microparticles and exosomes, are abundantly present in body fluids such as blood. Although such vesicles have gained strong clinical and scientific interest, their detection is difficult because many vesicles are extremely small with a diameter of less than 100 nm, and, moreover, these vesicles have a low refractive index and are heterogeneous in both size and composition. In this review, we focus on the relatively high throughput detection of vesicles in suspension by flow cytometry, resistive pulse sensing, and nanoparticle tracking analysis, and we will discuss their applicability and limitations. Finally, we discuss four methods that are not commercially available: Raman microspectroscopy, micro nuclear magnetic resonance, small-angle X-ray scattering (SAXS), and anomalous SAXS. These methods are currently being explored to study vesicles and are likely to offer novel information for future developments.
Collapse
|
23
|
Active caspase-3 is removed from cells by release of caspase-3-enriched vesicles. BIOCHIMICA ET BIOPHYSICA ACTA-MOLECULAR CELL RESEARCH 2013; 1833:1844-52. [PMID: 23531593 DOI: 10.1016/j.bbamcr.2013.03.013] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2012] [Revised: 02/12/2013] [Accepted: 03/15/2013] [Indexed: 01/21/2023]
Abstract
Cleavage of Rho associated Coiled Coil kinase I (ROCK I) by caspase-3 contributes to membrane blebbing. Whether caspase-3 and ROCK I also play a role in the release of membrane vesicles is unknown. Therefore, we transfected a human breast cancer cell line (MCF-7) that is caspase-3 deficient, lacks membrane blebbing, and does not release membrane vesicles, with caspase-3. Cells expressing caspase-3 demonstrate both ROCK I-mediated membrane blebbing, and release of small (400-600nm) membrane vesicles in a ROCK I-independent manner. These membrane vesicles contain caspase-3, and are enriched in caspase-3 activity compared to the releasing cells. Caspase-3-containing vesicles are taken up by untransfected cells but the cells do not show any sign of apoptosis. In conclusion, we show that the release of caspase-3-enriched membrane vesicles and membrane blebbing are two differentially regulated processes. Furthermore, we hypothesize that packaging of caspase-3 into membrane vesicles contributes to cellular homeostasis by the removal of caspase-3, and concurrently, protects the cells' environment from direct exposure to caspase-3 activity.
Collapse
|
24
|
Abstract
BACKGROUND Microparticles and exosomes are cell-derived vesicles and potential biomarkers for disease. Recently, the Scientific Standardization Committee collaborative workshop of the ISTH initiated standardization of vesicle detection by flow cytometry with polystyrene beads. Because polystyrene beads have different optical properties from biological vesicles, and because the mechanisms causing the detection signal are incompletely understood, there are contradictions between expected and observed results. OBJECTIVES To develop a model with which to relate the detection signal of a flow cytometer to the diameter of vesicles and clarify observed discrepancies. METHODS We combined measurements of polystyrene and silica beads with an estimated refractive index of vesicles and performed Mie calculations of light scattering. RESULTS We established the relationship between measured light scattering and the diameter of vesicles. The Megamix gating strategy proposed by the Scientific Standardization Committee selects single vesicles and cells with diameters between 800 and 2400 nm when applied on the forward-scattering detector of regular flow cytometers. Nevertheless, we demonstrated that, irrespective of the applied gating, multiple vesicles smaller than 220 nm or multiple 89-nm silica beads were counted as a single event signal at sufficiently high concentrations. CONCLUSIONS Vesicle detection by flow cytometry is attributed to large single vesicles and swarm detection of smaller vesicles; that is, multiple vesicles are simultaneously illuminated by the laser beam and counted as a single event signal. Swarm detection allows the detection of smaller vesicles than previously thought possible, and explains the finding that flow cytometry underestimates the concentration of vesicles.
Collapse
|
25
|
Circulating microparticles in patients with benign and malignant ovarian tumors. Anticancer Res 2012; 32:2009-2014. [PMID: 22593480] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
BACKGROUND Microparticles are known to be increased in various malignancies. In this prospective study, microparticle levels were evaluated in patients with benign and malignant ovarian lesions. PATIENTS AND METHODS Microparticles from platelets/megakaryocytes, activated platelets and endothelial cells, tissue factor exposing microparticles and D-dimer values were examined in patients with newly diagnosed ovarian lesions before surgery, and were correlated with tumor histology. RESULTS Higher counts of CD63-positive microparticles were detected in patients with ovarian cancer [mean=276×10(6) (range: 64-948)/l; n=12] as compared to patients with benign ovarian tumors [146×10(6) (45-390)/l; n=21; p=0.014]. D-dimer values were also increased in patients with cancer [860 (180-4500) ng/l versus 280 (170-2720) ng/l; p=0.001]. CONCLUSION Elevated levels of CD63-positive microparticles and D-dimer reflect the procoagulant phenotype of these patients. However, for the discrimination between benign and malignant ovarian tumors, measuring preoperative levels of microparticles does not seem to be helpful.
Collapse
|
26
|
To clot or not to clot: Procoagulant vesicles in human seminal fluid. J Reprod Immunol 2012. [DOI: 10.1016/j.jri.2012.03.265] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
27
|
Cellular origin and procoagulant activity of tissue factor-exposing microparticles in cancer patients. Thromb Res 2012. [DOI: 10.1016/s0049-3848(12)70049-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
28
|
The influence of aspirin dose and glycemic control on platelet inhibition in patients with type 2 diabetes mellitus. J Thromb Haemost 2012; 10:639-46. [PMID: 22252020 DOI: 10.1111/j.1538-7836.2012.04632.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND Low-dose aspirin seems to offer no benefit in the primary prevention of cardiovascular disease in type 2 diabetes mellitus (DM2). The anti-platelet effect may be diminished by poor glycemic control or inadequate dosing of aspirin. OBJECTIVES To study the effects of both glycemic control and increasing aspirin dose on platelet response to aspirin in DM2 patients and matched controls. PATIENTS/METHODS Platelet effects of increasing doses of aspirin (30, 100 and 300 mg daily) were prospectively assessed in 94 DM2 patients and 25 matched controls by measuring thromboxane levels in urine (11-dhTxB2) and platelet aggregation using VerifyNow(®) and light transmission aggregometry (LTA). DM2 patients were stratified for glycemic control (hemoglobin-A1c [HbA1c] ≤ 53, 53-69, ≥ 69 mmol mol(-1)). RESULTS At baseline, median 11-dhTxB2 excretion was higher in the poorly controlled patients (77 ng mmol(-1)), and the moderately controlled (84 ng mmol(-1)) compared with the well-controlled patients (64 ng mmol(-1)) and controls (53 ng mmol(-1)), P < 0.01. Next, 30 mg of aspirin reduced 11-dhTxB2 excretion to 31, 29 and 24 ng mmol(-1) in the poorly, moderately and well-controlled patients, respectively, and to 19 ng mmol(-1) in controls, P < 0.001. VerifyNow(®) and LTA were also incompletely suppressed in DM2 patients using 30 mg of aspirin, but 100 mg resulted in similar platelet suppression in all groups, with no additional effect of 300 mg. CONCLUSIONS DM2 patients with inadequate glycemic control (HbA1c > 53 mmol mol(-1)) have higher baseline platelet activity and incomplete suppression of platelet activity with 30 mg of aspirin. However, 100 mg of aspirin leads to optimal inhibition irrespective of glycemic control, and 300 mg does not further improve platelet suppression.
Collapse
|
29
|
|
30
|
|
31
|
FEMALE (IN)FERTILITY. Hum Reprod 2012. [DOI: 10.1093/humrep/27.s2.80] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
32
|
Abstract
At present, little is known about the clearance of platelet-derived microparticles (PMP) in human blood, as due to ethical considerations infusion experiments with labeled microparticles are delicate. Therefore, we investigated the kinetics of PMP, which are abundantly present in apheresis platelet concentrates (PC), following platelet transfusion in severe thrombocytopenic patients (n=11). PMP were double-stained with annexin V and cell-specific antibodies (anti-CD61, anti-CD63 or anti-CD62P, respectively) and detected by flow cytometry before and after transfusion of a single PC at fixed time intervals. Upon transfusion, the plasma levels of MP binding annexin V (2.5-fold), PMP (CD61+; 2.9-fold), and PMP from activated platelets (CD63+; 1.9-fold) or P-selectin (2.5-fold) increased immediately. The plasma levels of MP decreased with a half life of 5.8 hours (annexin V; 95% CI: 1.8?18.3) and 5.3 hours (CD61; 95% CI: 2.0?14.2). This is the first report in which the half life time of transfused PMP has been investigated in humans.
Collapse
|
33
|
Apheresis platelet concentrates contain platelet-derived and endothelial cell-derived microparticles. Vox Sang 2011; 100:179-86. [DOI: 10.1111/j.1423-0410.2010.01385.x] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
34
|
Abstract
Microparticles and exosomes are cell-derived microvesicles present in body fluids that play a role in coagulation, inflammation, cellular homeostasis and survival, intercellular communication, and transport. Despite increasing scientific and clinical interest, no standard procedures are available for the isolation, detection and characterization of microparticles and exosomes, because their size is below the reach of conventional detection methods. Our objective is to give an overview of currently available and potentially applicable methods for optical and non-optical determination of the size, concentration, morphology, biochemical composition and cellular origin of microparticles and exosomes. The working principle of all methods is briefly discussed, as well as their applications and limitations based on the underlying physical parameters of the technique. For most methods, the expected size distribution for a given microvesicle population is determined. The explanations of the physical background and the outcomes of our calculations provide insights into the capabilities of each method and make a comparison possible between the discussed methods. In conclusion, several (combinations of) methods can detect clinically relevant properties of microparticles and exosomes. These methods should be further explored and validated by comparing measurement results so that accurate, reliable and fast solutions come within reach.
Collapse
|
35
|
Complement activation on the surface of cell-derived microparticles during cardiac surgery with cardiopulmonary bypass - is retransfusion of pericardial blood harmful? Perfusion 2010; 26:21-9. [PMID: 20965956 DOI: 10.1177/0267659110385742] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
OBJECTIVES To investigate whether cell-derived microparticles play a role in complement activation in pericardial blood of patients undergoing cardiac surgery with cardiopulmonary bypass (CPB) and whether microparticles in pericardial blood contribute to systemic complement activation upon retransfusion. METHODS Pericardial blood of 13 patients was retransfused in 9 and discarded in 4 cases. Microparticles were isolated from systemic blood collected before anesthesia (T1) and at the end of CPB (T2), and from pericardial blood. The microparticles were analyzed by flow cytometry for bound complement components C1q, C4 and C3, and bound complement activator molecules C-reactive protein (CRP), serum amyloid P-component (SAP), immunoglobulin (Ig)M and IgG. Fluid-phase complement activation products (C4b/c, C3b/c) and activator molecules were determined by ELISA. RESULTS Compared with systemic T1 blood, pericardial blood contained increased C4b/c and C3b/c, and increased levels of microparticles with bound complement components. In systemic T1 samples, microparticle-bound CRP, whereas in pericardial blood, microparticle-bound SAP and IgM were associated with complement activation. At the end of CPB, increased C3b/c (but not C4b/c) was present in systemic T2 blood compared with T1, while concentrations of microparticles binding complement components and of those binding complement activator molecules were similar. Concentrations of fluid-phase complement activation products and microparticles were similar in patients whether or not retransfused with pericardial blood. CONCLUSIONS In pericardial blood of patients undergoing cardiac surgery with CPB, microparticles contribute to activation of the complement system via bound SAP and IgM. Retransfusion of pericardial blood, however, does not contribute to systemic complement activation.
Collapse
|
36
|
C-reactive protein in myocardial infarction binds to circulating microparticles but is not associated with complement activation. Clin Immunol 2010; 135:490-5. [PMID: 20138585 DOI: 10.1016/j.clim.2010.01.002] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2009] [Revised: 12/22/2009] [Accepted: 01/09/2010] [Indexed: 11/17/2022]
Abstract
BACKGROUND C-reactive protein (CRP) is elevated in patients with acute myocardial infarction (AMI). When CRP binds to membrane phospholipids or Fc receptors, it activates the complement system. Recent studies show that CRP can be exposed on cell-derived microparticles (MP) and is associated complement activation. OBJECTIVES We studied complement activation on circulating MP in AMI patients and healthy controls. METHODS MP were isolated from plasma of AMI patients (n=21) and sex- and age-matched healthy individuals (n=10), and analyzed by flow cytometry for bound complement components (C1q, C4, C3) and complement inhibitor and activator molecules (C4bp, CRP, serum amyloid P component, immunoglobulins IgM and IgG). Concurrently, the levels of fluid phase complement activation products and inhibitor and activator molecules were determined. RESULTS Fluid phase CRP, MP with bound CRP (CRP + MP), and C3 activation products were elevated in AMI patients compared to controls (P=0.032, P=0.031 and P=0.023, respectively), and fluid phase CRP correlated with CRP+ MP (r=0.84, P<0.001). Although CRP+ MP were elevated, they were not associated with C1q+ MP (r=0.32, P=0.174). In contrast, IgG+ MP were associated with C1q+ MP (r=0.73, P<0.001), C4+ MP and C3+ MP (r=0.78 and r=0.87, respectively; both P<0.001), and C4bp (r=0.63, P=0.004). In healthy individuals, CRP+ MP were strongly associated with C1q+ MP (r=0.82, P=0.007), which in turn were associated with C4+ MP and C3+ MP (r=0.68, P=0.032 and r=0.68, P=0.031, respectively). CONCLUSIONS Despite CRP-associated complement activation on the surface of MP in healthy individuals and a strong correlation between MP-bound CRP and fluid phase CRP in AMI patients, the MP-associated complement activation is IgG- but not CRP-dependent in AMI patients.
Collapse
|
37
|
Circulating microparticles remain associated with complement activation despite intensive anti-inflammatory therapy in early rheumatoid arthritis. Ann Rheum Dis 2009; 69:1378-82. [DOI: 10.1136/ard.2009.118372] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
38
|
|
39
|
Cell-derived microvesicles and cancer. Neth J Med 2009; 67:266-273. [PMID: 19687520] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Blood and other body f luids contain cell-derived microvesicles. The presence of microvesicles in cancer patients was already noticed in the late 1970s. Since then, the prothrombotic state in cancer patients has invariably been associated with the presence of such microvesicles. More recently, a growing body of evidence supports an important contribution of microvesicles to cancer cell survival, invasiveness and metastases. Here, we will present an overview of the many contributions of microvesicles to cancer development and progression. In addition, their role in risk stratification and treatment of cancer patients is discussed.
Collapse
|
40
|
|
41
|
Abstract
OBJECTIVES Platelets from healthy subjects are inhibited by insulin but type 2 diabetes mellitus (T2DM) platelets have become insulin-resistant, which might explain their hyperactivity. In the present study we investigated whether monocytes are responsive to insulin. METHODS AND RESULTS LPS-induced tissue factor (TF) upregulation was measured in human monocytes and monocytic THP-1 cells in a factor Xa generation assay. Insulin (0.1-100 nmol L(-1)) induced a dose-dependent inhibition in both cell types and in monocytes 100 nmol L(-1) insulin inhibited cytosolic, membrane-bound and microparticle TF by 32 +/- 2, 27 +/- 3 and 52 +/- 4% (n = 3). Insulin induced Tyr phosphorylation of the insulin receptor (INS-R) and formation of an INS-R - G(i)alpha(2) complex, suggesting interference with LPS-induced cAMP control. Indeed, insulin interfered with LPS-induced cAMP decrease and TF upregulation in a manner similar to an inhibitor of G(i) (pertussis toxin) and agents that raise cAMP (iloprost, forskolin, IBMX) reduced TF upregulation. Although LPS failed to raise cytosolic Ca(2+), quenching of Ca(2+) increases (BAPTA-AM) reduced and induction of Ca(2+) entry (ionophore, P2X7 activation) enhanced upregulation of TF mRNA and procoagulant activity. Insulin interfered with MCP-1-induced Ca(2+) mobilization but not with ATP-induced Ca(2+) rises. CONCLUSIONS Insulin inhibits TF expression in monocytes and monocyte-derived microparticles through interference with G(i)alpha(2)-mediated cAMP suppression, which attenuates Ca(2+)-mediated TF synthesis.
Collapse
|
42
|
Abstract
BACKGROUND Periodontitis is associated with an increased risk for cardiovascular diseases (CVD), but the underlying mechanisms are poorly understood. Recently, we showed that platelets from periodontitis patients are more activated than those from controls. OBJECTIVE Given the regularly occurring bacteremic episodes in periodontitis patients, we hypothesized that platelets and/or leukocytes from periodontitis patients are more sensitive to stimulation by oral bacteria, in particular the known periodontal pathogens, than platelets from control subjects. METHODS Three-color flow cytometry analysis was performed to quantify activation of platelets (P-selectin, PAC-1, CD63) and leukocytes (CD11b) in whole blood from patients with periodontitis (n = 19) and controls (n = 18), with and without stimulation by oral bacteria. Phagocytosis was assessed by using green-fluorescent protein (GFP)-expressing Aggregatibacter actinomycetemcomitans (Aa). RESULTS Neutrophils and monocytes were activated by all species of oral bacteria tested, but no differences were observed between patients and controls. In response to several species of oral bacteria, platelets from periodontitis patients showed, compared with controls, increased exposure of P-selectin (P = 0.027) and increased formation of platelet-monocyte complexes (P = 0.040). Platelet-leukocyte complexes bound and/or phagocytosed more GFP-Aa than platelet-free leukocytes (for neutrophils and monocytes, in both patients and controls, P < 0.001). CONCLUSIONS In periodontitis, increased platelet response to oral bacteria is paralleled by increased formation of platelet-leukocyte complexes with elevated capacity for bacterial clearance. We speculate that activated platelets and leukocytes might contribute to increased atherothrombotic activity.
Collapse
|
43
|
Placental corticotrophin-releasing hormone mRNA and microparticles in maternal plasma are not measures of placental shedding of debris: a rebuttal. J Thromb Haemost 2008; 6:1837-8; author reply 1838-9. [PMID: 18662259 DOI: 10.1111/j.1538-7836.2008.03100.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
44
|
|
45
|
Improvement of cognitive test performance in patients undergoing primary CABG and other CPB-assisted cardiac procedures. Perfusion 2008; 23:267-73. [DOI: 10.1177/0267659109104561] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Cardiac surgical procedures assisted by cardiopulmonary bypass (CPB) impair cognitive functions. Several studies, however, showed that cognitive functions were unaffected in patients undergoing either primary coronary artery bypass grafting (CABG) or more complex surgery assisted by CPB. Therefore, we conducted a straightforward study to compare patient groups who differed significantly in terms of risk factors such as prolonged CPB times. Consecutive patients (n = 54) were included, undergoing either non-primary CABG, e.g. valve and/or CABG, (n = 30) or primary CABG (n = 24), assisted by CPB. Cognitive function was determined pre-operatively on the day of hospital admission, and post-operatively after one and six months using the Cognitive Drug Research computerized assessment battery. Data from the fourteen individual task variables were summarized in four composite scores: Power of Attention (PoA), Continuity of Attention (CoA), Quality of Episodic Memory (QoEM), and Speed of Memory (SoM). In the non-primary CABG patients, both CoA and QoEM improved after 1 month (p = 0.001 and p = 0.016, respectively), whereas, after 6 months, CoA (p = 0.002), QoEM (p = 0.002) and SoM (p < 0.001) were improved. In primary CABG patients, CoA improved at one month after surgery (p = 0.002) and, after six months, not only CoA (p = 0.003), but also QoEM and SoM were improved (p = 0.001 and p = 0.030, respectively). The test performance was similar in non-primary and primary CABG patients after surgery. Our present study shows a post-operative improvement of cognitive composite scores after cardiac surgery assisted by CPB in both non-primary CABG and in primary CABG patients.
Collapse
|
46
|
Phospholipid composition of in vitro endothelial microparticles and their in vivo thrombogenic properties. Thromb Res 2008; 121:865-71. [PMID: 17889282 DOI: 10.1016/j.thromres.2007.08.005] [Citation(s) in RCA: 73] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2007] [Revised: 07/31/2007] [Accepted: 08/01/2007] [Indexed: 11/21/2022]
Abstract
INTRODUCTION Microparticles from activated endothelial cells (EMP) are well known to expose tissue factor (TF) and initiate coagulation in vitro. TF coagulant activity is critically dependent on the presence of aminophospholipids, such as phosphatidylserine (PS) and phosphatidylethanolamine (PE), but it is unknown whether or not TF-exposing EMP are enriched in such aminophospholipids. Furthermore, despite the fact that EMP have been reported in several pathological conditions, direct evidence for their (putative) coagulant properties in vivo is still lacking. We investigated the phospholipid composition of endothelial MP (EMP) and their thrombogenic properties in vivo. MATERIALS AND METHODS Human umbilical vein endothelial cells (HUVEC; n=3) were incubated with or without interleukin (IL)-1alpha (5 ng/mL; 0-72 h). Phospholipid composition of EMP was determined by high-performance thin layer chromatography. The association between EMP, TF antigen and activity was confirmed in vitro (ELISA, Western blot and thrombin generation). Thrombogenic activity of EMP in vivo was determined in a rat venous stasis model. RESULTS Levels of TF antigen increased 3-fold in culture medium of IL-1alpha-treated cells (P<0.0001). This TF antigen was associated with EMP and appeared as a 45-47 kDa protein on Western blot. In addition, EMP from activated cells were enriched in both PS (P<0.0001) and PE (P<0.0001), and triggered TF-dependent thrombin formation in vitro and thrombus formation in vivo. In contrast, EMP from control cells neither initiated coagulation in vitro nor thrombus formation in vivo. CONCLUSIONS EMP from activated endothelial cells expose coagulant tissue factor and are enriched in its cofactors PS and PE.
Collapse
|
47
|
Cell-Derived Microparticles and Complement Activation in Preeclampsia Versus Normal Pregnancy. Placenta 2007; 28:928-35. [PMID: 17433833 DOI: 10.1016/j.placenta.2007.02.008] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2006] [Revised: 02/19/2007] [Accepted: 02/20/2007] [Indexed: 11/21/2022]
Abstract
BACKGROUND Inflammation plays a major role in the vascular dysfunction seen in preeclampsia, and several studies suggest involvement of the complement system. OBJECTIVES To investigate whether complement activation on the surface of microparticles is increased in plasma of preeclamptic patients versus healthy pregnant controls. METHODS Microparticles from plasma of preeclamptic (n=10), healthy pregnant (n=10) and healthy nonpregnant (n=10) women were analyzed by flow cytometry for bound complement components (C1q, C4, C3) and complement activator molecules (C-reactive protein [CRP], serum amyloid P component [SAP], immunoglobulin [Ig]M, IgG). Fluid phase complement activation products and activator molecules were also determined. RESULTS Levels of microparticles with bound complement components showed no increase in complement activation on the microparticle surface in preeclamptic women, in line with levels of fluid phase complement activation products. In healthy nonpregnant and pregnant women, bound CRP was associated with classical pathway activation on the microparticle surface, and in healthy pregnant women IgM and IgG molecules also contributed. In preeclamptic women, microparticles with bound SAP and those with IgG seemed to contribute to C1q binding without a clear association to further classical pathway activation. Furthermore, significantly increased levels of microparticles with bound CRP were present in preeclamptic compared with healthy pregnant women (median 178x10(6)/L versus 47x10(6)/L, P<0.01), but without concomitant increases in complement activation. CONCLUSIONS We found no evidence of increased complement activation on the microparticle surface in preeclamptic women. Microparticles with bound CRP were significantly increased, but in contrast to healthy pregnant and nonpregnant women, this was not associated with increased classical pathway activation on the surface of the microparticles.
Collapse
|
48
|
ANALYSIS OF MICROPARTICLES IN DEEP VENOUS THROMBOSIS AND ANTIPHOSPHOLIPID SYNDROME PATIENTS AND CARRIERS OF LEIDEN FACTOR V. J Thromb Haemost 2007. [DOI: 10.1111/j.1538-7836.2007.tb00620.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
49
|
RETRANSFUSION OF PERICARDIAL BLOOD DOES NOT TRIGGER SYSTEMIC COAGULATION DURING CARDIOPULMONARY BYPASS. J Thromb Haemost 2007. [DOI: 10.1111/j.1538-7836.2007.tb01176.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
50
|
CELL-DERIVED MICROPARTICLES AND COMPLEMENT ACTIVATION IN PREECLAMPSIA VERSUS NORMAL PREGNANCY. J Thromb Haemost 2007. [DOI: 10.1111/j.1538-7836.2007.tb00613.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|