1
|
Rossi GP, Barisa M, Allolio B, Auchus RJ, Amar L, Cohen D, Degenhart C, Deinum J, Fischer E, Gordon R, Kickuth R, Kline G, Lacroix A, Magill S, Miotto D, Naruse M, Nishikawa T, Omura M, Pimenta E, Plouin PF, Quinkler M, Reincke M, Rossi E, Rump LC, Satoh F, Schultze Kool L, Seccia TM, Stowasser M, Tanabe A, Trerotola S, Vonend O, Widimsky J, Wu KD, Wu VC, Pessina AC. The Adrenal Vein Sampling International Study (AVIS) for identifying the major subtypes of primary aldosteronism. J Clin Endocrinol Metab 2012; 97:1606-14. [PMID: 22399502 DOI: 10.1210/jc.2011-2830] [Citation(s) in RCA: 266] [Impact Index Per Article: 20.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
CONTEXT In patients who seek surgical cure of primary aldosteronism (PA), The Endocrine Society Guidelines recommend the use of adrenal vein sampling (AVS), which is invasive, technically challenging, difficult to interpret, and commonly held to be risky. OBJECTIVE The aim of this study was to determine the complication rate of AVS and the ways in which it is performed and interpreted at major referral centers. DESIGN AND SETTINGS The Adrenal Vein Sampling International Study is an observational, retrospective, multicenter study conducted at major referral centers for endocrine hypertension worldwide. PARTICIPANTS Eligible centers were identified from those that had published on PA and/or AVS in the last decade. MAIN OUTCOME MEASURE The protocols, interpretation, and costs of AVS were measured, as well as the rate of adrenal vein rupture and the rate of use of AVS. RESULTS Twenty of 24 eligible centers from Asia, Australia, North America, and Europe participated and provided information on 2604 AVS studies over a 6-yr period. The percentage of PA patients systematically submitted to AVS was 77% (median; 19-100%, range). Thirteen of the 20 centers used sequential catheterization, and seven used bilaterally simultaneous catheterization; cosyntropin stimulation was used in 11 centers. The overall rate of adrenal vein rupture was 0.61%. It correlated directly with the number of AVS performed at a particular center (P = 0.002) and inversely with the number of AVS performed by each radiologist (P = 0.007). CONCLUSIONS Despite carrying a minimal risk of adrenal vein rupture and at variance with the guidelines, AVS is not used systematically at major referral centers worldwide. These findings represent an argument for defining guidelines for this clinically important but technically demanding procedure.
Collapse
|
Clinical Trial |
13 |
266 |
2
|
Dufour JF, Hoppe H, Heim MH, Helbling B, Maurhofer O, Szucs-Farkas Z, Kickuth R, Borner M, Candinas D, Saar B. Continuous administration of sorafenib in combination with transarterial chemoembolization in patients with hepatocellular carcinoma: results of a phase I study. Oncologist 2010; 15:1198-204. [PMID: 21036880 DOI: 10.1634/theoncologist.2010-0180] [Citation(s) in RCA: 72] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
BACKGROUND AND AIM It is unknown whether sorafenib can be combined with transarterial chemoembolization (TACE) in patients with hepatocellular carcinoma. This study assesses the safety and tolerability of a continuous regimen of sorafenib combined with TACE. METHODS This was an open-label phase I study testing a continuous administration of sorafenib (dose escalation from 200 mg twice daily [bid] to 400 mg bid) starting 7 days prior to TACE with doxorubicin (50 mg). RESULTS Twenty-one patients were screened and 14 received sorafenib combined with TACE. Because there were no dose-limiting toxicities in the first three patients who received sorafenib at a dose of 200 mg bid, subsequent patients received 400 mg bid. Twenty-seven procedures were performed (median, two per patient) and two local therapy-related severe adverse events occurred. The median duration of sorafenib therapy was 246 days (range, 14-547 days). Sorafenib-related adverse events of grade ≥3 were hand-foot skin reaction (n = 3), weight loss (n = 2), diarrhea (n = 1), abdominal pain (n = 1), and thrombocytopenia (n = 3). After treatment with sorafenib and TACE, there was a significant decrease in the concentration of plasma vascular endothelial growth factor (VEGF) from 93 ng/l to 67 ng/l. CONCLUSIONS Continuous administration of sorafenib at a dose of 400 mg bid combined with TACE was tolerable. The adverse event profile of this regimen was comparable with that of sorafenib monotherapy with the exception of thrombocytopenia, which may be more frequent. There were no increases in the circulating VEGF levels after TACE with this combined regimen. (Swiss Association for the Study of the Liver study number 25; ClinicalTrials.gov trial identifier, NCT00478374).
Collapse
|
Research Support, Non-U.S. Gov't |
15 |
72 |
3
|
Kirchner J, Kickuth R, Laufer U, Noack M, Liermann D. Optimized enhancement in helical CT: experiences with a real-time bolus tracking system in 628 patients. Clin Radiol 2000; 55:368-73. [PMID: 10816403 DOI: 10.1053/crad.2000.0376] [Citation(s) in RCA: 61] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
AIMS Ultrafast detector technology enables bolus-triggered application of contrast media. In a prospective study we investigated the benefit of this new method with the intention of optimizing enhancement during examination of the chest and abdomen. MATERIALS AND METHODS In total, we examined 548 patients under standardized conditions. All examinations were performed on a Somatom Plus 4 Power CT system (Siemens Corp., Forchheim, Germany) using the CARE-Bolus software. This produces repetitive low-dose test images (e.g. for the lung: 140 kV, 43 mA, TI 0.5 s) and measures the Hounsfield attenuation in a pre-selected region of interest. After exceeding a defined threshold, a diagnostic spiral CT examination was begun automatically. The data obtained from 321 abdominal CT and 179 lung CT examinations were correlated with different parameters such as age, weight and height of the patients and parameters of vascular access. In a group of 80 patients, the injection of contrast medium was stopped after reaching a pre-defined threshold of an increase of 100 HU over the baseline. Then, we assessed the maximal enhancement of liver, pulmonal artery trunk and aortic arch. RESULTS There was no correlation between bolus geometry and age, body surface or weight. In helical CT of the abdomen the threshold was reached after a mean trigger time of 27 s (range 13-67 s) and only 65 ml (range 41-105 ml) of contrast medium were administered. In helical CT of the lung the threshold was reached after 21 s (range 12-48 s) and the mean amount of administered contrast medium was 48 ml (range 38-71 ml). CONCLUSION Bolus triggering allows optimized enhancement of the organs and reduces the dose of contrast material required compared with standard administration.
Collapse
|
Clinical Trial |
25 |
61 |
4
|
Kickuth R, Rattunde H, Gschossmann J, Inderbitzin D, Ludwig K, Triller J. Acute Lower Gastrointestinal Hemorrhage: Minimally Invasive Management with Microcatheter Embolization. J Vasc Interv Radiol 2008; 19:1289-96.e2. [DOI: 10.1016/j.jvir.2008.06.003] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2007] [Revised: 05/15/2008] [Accepted: 06/02/2008] [Indexed: 11/24/2022] Open
|
|
17 |
45 |
5
|
Kickuth R, Keo HH, Triller J, Ludwig K, Do DD. Initial Clinical Experience with the 4-F Self-expanding XPERT Stent System for Infrapopliteal Treatment of Patients with Severe Claudication and Critical Limb Ischemia. J Vasc Interv Radiol 2007; 18:703-8. [PMID: 17538131 DOI: 10.1016/j.jvir.2007.03.012] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
PURPOSE To evaluate the primary success and short-term patency associated with a new 4-F sheath-compatible self-expanding nitinol stent after failed conventional angioplasty of distal popliteal and infrapopliteal lesions in severe lifestyle-limiting claudication (LLC) and chronic critical limb ischemia (CLI). MATERIALS AND METHODS Between May 2003 and July 2005, 35 patients with Rutherford category 3-5 disease (16 patients with CLI, 19 patients with LLC) underwent percutaneous transluminal angioplasty (PTA) and stent implantation. Indications for stent placement were residual stenosis, flow-limiting dissections, or elastic recoil after PTA. Before and after the intervention and during the 6-month follow-up, clinical investigation, color-flow and duplex Doppler ultrasonography, and digital subtraction angiography were performed. Technical success, primary patency at 6 months, clinical improvement as defined by Rutherford with clinical and hemodynamic measures, and complications were evaluated. RESULTS A total of 22 patients underwent distal popliteal artery stent placement and 13 underwent tibioperoneal artery stent placement. Stent implantation was successfully performed in all patients. After stent placement, the primary cumulative patency rate for the study group at 6 months was 82%. The mean resting ankle-brachial index at baseline was 0.50 +/- 0.16 and significantly increased to 0.90 +/- 0.17 at 12-24 hours after intervention and 0.82 +/- 0.24 at latest follow-up (P < .001 for both). The sustained clinical improvement rate was 80% at the 6-month follow-up. The 6-month limb salvage rate regarding major amputation was 100%. The rate of major complications was 17%. CONCLUSIONS Infrapopliteal application of the new nitinol stent is a safe, feasible, and effective method with good short-term patency rate in the treatment of severe LLC and chronic CLI.
Collapse
|
|
18 |
43 |
6
|
Krankenberg H, Zeller T, Ingwersen M, Schmalstieg J, Gissler HM, Nikol S, Baumgartner I, Diehm N, Nickling E, Müller-Hülsbeck S, Schmiedel R, Torsello G, Hochholzer W, Stelzner C, Brechtel K, Ito W, Kickuth R, Blessing E, Thieme M, Nakonieczny J, Nolte T, Gareis R, Boden H, Sixt S. Self-Expanding Versus Balloon-Expandable Stents for Iliac Artery Occlusive Disease. JACC Cardiovasc Interv 2017; 10:1694-1704. [DOI: 10.1016/j.jcin.2017.05.015] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/06/2017] [Revised: 04/28/2017] [Accepted: 05/04/2017] [Indexed: 01/18/2023]
|
|
8 |
43 |
7
|
Goltz JP, Ritter CO, Kellersmann R, Klein D, Hahn D, Kickuth R. Endovascular Treatment of Popliteal Artery Segments P1 and P2 in Patients With Critical Limb Ischemia: Initial Experience Using a Helical Nitinol Stent With Increased Radial Force. J Endovasc Ther 2012; 19:450-6. [DOI: 10.1583/11-3591mr.1] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
|
13 |
40 |
8
|
Kickuth R, Anderson S, Kocovic L, Ludwig K, Siebenrock K, Triller J. Endovascular treatment of arterial injury as an uncommon complication after orthopedic surgery. J Vasc Interv Radiol 2006; 17:791-9. [PMID: 16687744 DOI: 10.1097/01.rvi.0000217929.35607.15] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
PURPOSE To evaluate selective and superselective catheter therapy of serious arterial damage associated with orthopedic surgery of the pelvis, hip joint, femur, and knee. MATERIALS AND METHODS Between 1989 and 2005, 16 consecutive patients with arterial damage after orthopedic surgery (seven women, nine men; mean age, 62 years; age range, 21-82 y) underwent angiographic exploration. Seven patients were in hemodynamically unstable condition. Initial orthopedic procedures were iliac crest internal fixation (n = 1); total hip prosthesis (n = 3); revision of total hip prosthesis (n = 4); revision of acetabular cup prosthesis (n = 1); gamma-nailing, nail-plate fixation, or intramedullary nailing (n = 3); and total knee prosthesis (n = 4). RESULTS Angiography showed pseudoaneurysms (n = 11), vascular lacerations with active extravasation (n = 3), and arteriovenous fistulas with extravasation (n = 2). After angiographic documentation of serious arterial injury, 14 patients were treated with a single or coaxial catheter technique in combination with coils alone, coils and polyvinyl alcohol particles, coils and Gelfoam pledgets, or Gelfoam pledgets; or balloon occlusion with isobutyl cyanoacrylate and coils. Two patients were treated with covered stents. In all, bleeding was effectively controlled in a single session in 16 patients, with immediate circulatory stabilization. Major complications included death, pulmonary embolism, and postprocedural hematoma. CONCLUSION Selective and superselective catheter therapy may be used for effective, minimally invasive management of rare but potentially life-threatening vascular complications after orthopedic surgery.
Collapse
|
Journal Article |
19 |
38 |
9
|
Schnüriger B, Inderbitzin D, Schafer M, Kickuth R, Exadaktylos A, Candinas D. Concomitant injuries are an important determinant of outcome of high-grade blunt hepatic trauma. Br J Surg 2009; 96:104-10. [PMID: 19109805 DOI: 10.1002/bjs.6439] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
BACKGROUND Little is known about the clinical importance of concomitant injuries in polytraumatized patients with high-grade blunt liver injury. A retrospective single-centre study was performed to investigate the safety of non-operative management of liver injury and the impact of concomitant intra- and extra-abdominal injuries on clinical outcome. METHODS Some 183 patients with blunt liver injury were admitted to Berne University Hospital, Switzerland, between January 2000 and December 2006. Grade 3-5 injuries were considered to be high grade. RESULTS Immediate laparotomy was required by 35 patients (19.1 per cent), owing to extrahepatic intra-abdominal injury (splenic and vascular injuries, perforations) in 21 cases. The mortality rate was 16.9 per cent; 22 of the 31 deaths were due to concomitant lesions. Of 81 patients with high-grade liver injury, 63 (78 per cent) were managed without surgery; liver-related and extra-abdominal complication rates in these patients were 11 and 17 per cent respectively. Grades 4 and 5 liver injury were associated with hepatic-related and extra-abdominal complications. CONCLUSION Concomitant injuries are a major determinant of outcome in patients with blunt hepatic injury and should be given high priority by trauma surgeons. An algorithm for the management of blunt liver injury is proposed.
Collapse
|
Journal Article |
16 |
37 |
10
|
Goltz JP, Scholl A, Ritter CO, Wittenberg G, Hahn D, Kickuth R. Peripherally Placed Totally Implantable Venous-access Port Systems of the Forearm: Clinical Experience in 763 Consecutive Patients. Cardiovasc Intervent Radiol 2010; 33:1159-67. [DOI: 10.1007/s00270-010-9854-6] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2009] [Accepted: 03/23/2010] [Indexed: 01/02/2023]
|
|
15 |
34 |
11
|
Kirchner J, Kickuth R, Laufer U, Schilling EM, Adams S, Liermann D. CT fluoroscopy-assisted puncture of thoracic and abdominal masses: a randomized trial. Clin Radiol 2002; 57:188-92. [PMID: 11952312 DOI: 10.1053/crad.2001.0716] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
PURPOSE We investigated the benefit of real-time guidance of interventional punctures by means of computed tomography fluoroscopy (CTF) compared with the conventional sequential acquisition guidance. MATERIAL AND METHODS In a prospective randomized trial, 75 patients underwent either CTF-guided (group A, n = 50) or sequential CT-guided (group B, n = 25) punctures of thoracic (n = 29) or abdominal (n = 46) masses. CTF was performed on the CT machine (Somatom Plus 4 Power, Siemens Corp., Forchheim, Germany) equipped with the C.A.R.E. Vision application (tube voltage 120 kV, tube current 50 mA, rotational time 0.75 s, slice thickness 10 mm, 8 frames/s). RESULTS The average procedure time showed a statistically significant difference between the two study groups (group A: 564 s, group B 795 s, P = 0.0032). The mean total mAs was 7089 mAs for the CTF and 4856 mAs for the sequential image-guided intervention, respectively. The sensitivity was 71% specificity 100% positive predictive value 100% and negative predictive value 60% for the CTF-guided puncture, and 68, 100, 100 and 50% for sequential CT, respectively. CONCLUSION CTF guidance realizes a time-saving but increases the radiation exposure dosage.
Collapse
|
Clinical Trial |
23 |
33 |
12
|
Baur J, Ritter CO, Germer CT, Klein I, Kickuth R, Steger U. Transarterial chemoembolization with drug-eluting beads versus conventional transarterial chemoembolization in locally advanced hepatocellular carcinoma. Hepat Med 2016; 8:69-74. [PMID: 27382341 PMCID: PMC4920234 DOI: 10.2147/hmer.s105395] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Purpose In hepatocellular carcinoma patients with large or multinodal tumors, where curative treatment options are not feasible, transarterial therapies play a major role. Transarterial chemoembolization (TACE) with drug-eluting beads (DEB-TACE) is a promising new approach due to higher intratumoral and lower systemic concentration of the chemotherapeutic agent compared to conventional TACE (cTACE). Patients and methods In a retrospective analysis, 32 patients with hepatocellular carcinoma who received either DEB or a cTACE were compared regarding survival time, disease recurrence, and side effects such as pain and fever. Results No significant differences could be detected between the cTACE and DEB-TACE groups with regard to mean hospital stay, appearance of postinterventional fever, or 30-day mortality. However, the application of intravenous analgesics as postinterventional pain medication was needed more often in patients treated with DEB-TACE (57.1% vs 12.5%, P=0.0281). The overall median survival after the initial procedure was 10.8 months in the cTACE group and 9.2 months in the DEB-TACE group, showing no significant difference. Conclusion No survival benefit for patients treated with either DEB-TACE or cTACE was observed. Surprisingly, a higher rate of postinterventional pain could be detected after DEB-TACE.
Collapse
|
Journal Article |
9 |
33 |
13
|
Kickuth R, Dick F, Triller J, Ludwig K, Schmidli J, Do DD. Internal Iliac Artery Embolization before Endovascular Repair of Aortoiliac Aneurysms with a Nitinol Vascular Occlusion Plug. J Vasc Interv Radiol 2007; 18:1081-7. [PMID: 17804768 DOI: 10.1016/j.jvir.2007.06.013] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
Abstract
PURPOSE To evaluate the acute and midterm effectiveness of a novel vascular occlusion device for embolization of the internal iliac artery (IIA) before endovascular repair of aortoiliac aneurysms. MATERIALS AND METHODS Between March 2005 and April 2006, nine men (mean age, 75 years +/- 5; range, 66-83 y) with aortoiliac aneurysms underwent bifurcated endovascular stent-graft procedures. All these patients were referred specifically for embolization. Pre- and perioperatively, eight patients underwent unilateral embolization and one underwent bilateral embolization of the IIA to prevent type II endoleak. Via a contralateral femoral approach with a 6-F or 8-F sheath, the embolization procedure was performed with an Amplatzer Vascular Plug, a self-expandable cylindrical device consisting of a nitinol-based wire mesh. Technical success, clinical outcome, and complications were evaluated. Follow-up at 3, 6, and 12 months was performed with clinical and radiologic examinations. RESULTS IIA embolization was technically successful in all cases and no procedure-related complications occurred. Imaging at discharge and at 3-, 6-, or 12-month follow-up was accomplished in all nine patients. Control computed tomography and magnetic resonance angiography did not reveal retrograde perfusion of the aneurysmal sac, ie, type II endoleak. Three of nine patients (33.3%) reported symptoms of buttock claudication that did not resolve completely. Clinical symptoms such as bowel ischemia or sexual dysfunction were not observed. CONCLUSIONS The midterm results of this study suggest that preoperative IIA embolization with a nitinol vascular occlusion plug during endovascular treatment of aortoiliac aneurysms is safe and effective.
Collapse
|
|
18 |
32 |
14
|
Diehm N, Kickuth R, Baumgartner I, Srivastav SK, Gretener S, Husmann MJ, Jaccard Y, Do DD, Triller J, Bonel HM. Magnetic Resonance Angiography in Infrapopliteal Arterial Disease. Invest Radiol 2007; 42:467-76. [PMID: 17507820 DOI: 10.1097/01.rli.0000262581.52315.ef] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To prospectively determine the accuracy of 1.5 Tesla (T) and 3 T magnetic resonance angiography (MRA) versus digital subtraction angiography (DSA) in the depiction of infrageniculate arteries in patients with symptomatic peripheral arterial disease. PATIENTS AND METHODS A prospective 1.5 T, 3 T MRA, and DSA comparison was used to evaluate 360 vessel segments in 10 patients (15 limbs) with chronic symptomatic peripheral arterial disease. Selective DSA was performed within 30 days before both MRAs. The accuracy of 1.5 T and 3 T MRA was compared with DSA as the standard of reference by consensus agreement of 2 experienced readers. Signal-to-noise ratios (SNR) and signal-difference-to-noise ratios (SDNRs) were quantified. RESULTS No significant difference in overall image quality, sufficiency for diagnosis, depiction of arterial anatomy, motion artifacts, and venous overlap was found comparing 1.5 T with 3 T MRA (P > 0.05 by Wilcoxon signed rank and as by Cohen k test). Overall sensitivity of 1.5 and 3 T MRA for detection of significant arterial stenosis was 79% and 82%, and specificity was 87% and 87% for both modalities, respectively. Interobserver agreement was excellent k > 0.8, P < 0.05) for 1.5 T as well as for 3 T MRA. SNR and SDNR were significantly increased using the 3 T system (average increase: 36.5%, P < 0.032 by t test, and 38.5%, P < 0.037 respectively). CONCLUSIONS Despite marked improvement of SDNR, 3 T MRA does not yet provide a significantly higher accuracy in diagnostic imaging of atherosclerotic lesions below the knee joint as compared with 1.5 T MRA.
Collapse
|
|
18 |
32 |
15
|
Hassold N, Wolfschmidt F, Dierks A, Klein I, Bley T, Kickuth R. Effectiveness and outcome of endovascular therapy for late-onset postpancreatectomy hemorrhage using covered stents and embolization. J Vasc Surg 2016; 64:1373-1383. [DOI: 10.1016/j.jvs.2016.05.071] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2016] [Accepted: 05/28/2016] [Indexed: 12/19/2022]
|
|
9 |
32 |
16
|
Kickuth R. [Ecochemical capacities of higher plants]. THE SCIENCE OF NATURE - NATURWISSENSCHAFTEN 1970; 57:55-61. [PMID: 5430093 DOI: 10.1007/bf00590679] [Citation(s) in RCA: 31] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
|
55 |
31 |
17
|
Herz S, Vogel P, Dietrich P, Kampf T, Rückert MA, Kickuth R, Behr VC, Bley TA. Magnetic Particle Imaging Guided Real-Time Percutaneous Transluminal Angioplasty in a Phantom Model. Cardiovasc Intervent Radiol 2018; 41:1100-1105. [PMID: 29663052 DOI: 10.1007/s00270-018-1955-7] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2018] [Accepted: 03/31/2018] [Indexed: 11/30/2022]
Abstract
PURPOSE To investigate the potential of real-time magnetic particle imaging (MPI) to guide percutaneous transluminal angioplasty (PTA) of vascular stenoses in a phantom model. MATERIALS AND METHODS Experiments were conducted on a custom-built MPI scanner. Vascular stenosis phantoms consisted of polyvinyl chloride tubes (inner diameter 8 mm) prepared with a centrally aligned cable tie to form ~ 50% stenoses. MPI angiography for visualization of stenoses was performed using the superparamagnetic iron oxide nanoparticle-based contrast agent Ferucarbotran (10 mmol (Fe)/l). Balloon catheters and guidewires for PTA were visualized using custom-made lacquer markers based on Ferucarbotran. Stenosis dilation (n = 3) was performed by manually inflating the PTA balloon with diluted Ferucarbotran. An online reconstruction framework was implemented for real-time imaging with very short latency time. RESULTS Visualization of stenosis phantoms and guidance of interventional instruments in real-time (4 frames/s, ~ 100 ms latency time) was possible using an online reconstruction algorithm. Labeling of guidewires and balloon catheters allowed for precise visualization of instrument positions. CONCLUSION Real-time MPI-guided PTA in a phantom model is feasible.
Collapse
|
Journal Article |
7 |
29 |
18
|
Duhr CD, Kenn W, Kickuth R, Kerscher AG, Germer CT, Hahn D, Pelz JOW. Optimizing of preoperative computed tomography for diagnosis in patients with peritoneal carcinomatosis. World J Surg Oncol 2011; 9:171. [PMID: 22188796 PMCID: PMC3280941 DOI: 10.1186/1477-7819-9-171] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2011] [Accepted: 12/21/2011] [Indexed: 12/13/2022] Open
Abstract
Background and Objective This study evaluates whether Computer Tomography is an effective procedure for preoperative staging of patients with Peritoneal Carcinomatosis. Method A sample of 37 patients was analyzed with contrast enhanced abdominal Computer Tomography, followed by surgical staging. All Computer Tomography scans were evaluated 3 times by 2 radiologists with one radiologist reviewing 2 times. The efficacy of Computer Tomography was evaluated using the Spearman correlation coefficient. Correlations were analyzed by abdominopelvic region to assess results of the Peritoneal Carcinomatosis Index (PCI) aggregating the 13 regions. Surgical findings were compared to radiological findings. Results Results indicate high correlations between the surgical and radiological Peritoneal Carcinomatosis Indices. Analyses of the intra-class correlation between the first and second reading of one radiologist suggest high intra-observer reliability. Correlations by abdominopelvic region show higher values in the upper and middle regions and relatively lower values in the lower regions and the small bowel (correlation coefficients range between 0.418 and 0.726, p < 0.010; sensitivities range between 50% and 96%; and specificities range between 62% and 100%). Conclusion Computer Tomography represents an effective procedure in the preoperative staging of patients with PC. However, results by abdominopelvic region show lower correlation, therefore suggest lower efficacy. These results are supported by analyses of sensitivity and accuracy by lesion size. This suggests that Computer Tomography is an effective procedure for pre-operative staging but less for determining a tumor's accurate extent.
Collapse
|
Journal Article |
14 |
28 |
19
|
Goltz JP, Noack C, Petritsch B, Kirchner J, Hahn D, Kickuth R. Totally implantable venous power ports of the forearm and the chest: initial clinical experience with port devices approved for high-pressure injections. Br J Radiol 2012; 85:e966-72. [PMID: 22674705 DOI: 10.1259/bjr/33224341] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
OBJECTIVES To evaluate the technical success, clinical outcome and safety of percutaneously placed totally implantable venous power ports (TIVPPs) approved for high-pressure injections, and to analyse their value for arterial phase CT scans. METHODS Retrospectively, we identified 204 patients who underwent TIVPP implantation in the forearm (n=152) or chest (n=52) between November 2009 and May 2011. Implantation via an upper arm (forearm port, FP) or subclavian vein (chest port, CP) was performed under sonographic and fluoroscopic guidance. Complications were evaluated following the standards of the Society of Interventional Radiology. Power injections via TIVPPs were analysed, focusing on adequate functioning and catheter's tip location after injection. Feasibility of automatic bolus triggering, peak injection pressure and arterial phase aortic enhancement were evaluated and compared with 50 patients who had had power injections via classic peripheral cannulas. RESULTS Technical success was 100%. Procedure-related complications were not observed. Catheter-related thrombosis was diagnosed in 15 of 152 FPs (9.9%, 0.02/100 catheter days) and in 1 of 52 CPs (1.9%, 0.002/100 catheter days) (p<0.05). Infectious complications were diagnosed in 9 of 152 FPs (5.9%, 0.014/100 catheter days) and in 2 of 52 CPs (3.8%, 0.003/100 catheter days) (p>0.05). Arterial bolus triggering succeeded in all attempts; the mean injection pressure was 213.8 psi. Aortic enhancement did not significantly differ between injections via cannulas and TIVPPs (p>0.05). CONCLUSIONS TIVPPs can be implanted with high technical success rates, and are associated with low rates of complications if implanted with sonographic and fluoroscopic guidance. Power injections via TIVPPs are safe and result in satisfying arterial contrast. Conventional ports should be replaced by TIVPPs.
Collapse
|
Journal Article |
13 |
27 |
20
|
Schnüriger B, Kilz J, Inderbitzin D, Schafer M, Kickuth R, Luginbühl M, Candinas D, Exadaktylos AK, Zimmermann H. The accuracy of FAST in relation to grade of solid organ injuries: a retrospective analysis of 226 trauma patients with liver or splenic lesion. BMC Med Imaging 2009; 9:3. [PMID: 19323813 PMCID: PMC2667168 DOI: 10.1186/1471-2342-9-3] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2008] [Accepted: 03/26/2009] [Indexed: 11/12/2022] Open
Abstract
Background This study investigated the role of a negative FAST in the diagnostic and therapeutic algorithm of multiply injured patients with liver or splenic lesions. Methods A retrospective analysis of 226 multiply injured patients with liver or splenic lesions treated at Bern University Hospital, Switzerland. Results FAST failed to detect free fluid or organ lesions in 45 of 226 patients with spleen or liver injuries (sensitivity 80.1%). Overall specificity was 99.5%. The positive and negative predictive values were 99.4% and 83.3%. The overall likelihood ratios for a positive and negative FAST were 160.2 and 0.2. Grade III-V organ lesions were detected more frequently than grade I and II lesions. Without the additional diagnostic accuracy of a CT scan, the mean ISS of the FAST-false-negative patients would be significantly underestimated and 7 previously unsuspected intra-abdominal injuries would have been missed. Conclusion FAST is an expedient tool for the primary assessment of polytraumatized patients to rule out high grade intra-abdominal injuries. However, the low overall diagnostic sensitivity of FAST may lead to underestimated injury patterns and delayed complications may occur. Hence, in hemodynamically stable patients with abdominal trauma, an early CT scan should be considered and one must be aware of the potential shortcomings of a "negative FAST".
Collapse
|
Journal Article |
16 |
27 |
21
|
Stueckle CA, Haegele KF, Jendreck M, Zipser MC, Kirchner J, Kickuth R, Liermann D. Multislice computed tomography angiography of the abdominal arteries: Comparison between computed tomography angiography and digital subtraction angiography findings in 52 cases. ACTA ACUST UNITED AC 2004; 48:142-7. [PMID: 15230747 DOI: 10.1111/j.1440-1673.2004.01275.x] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Since the introduction of multislice CT scanners, CT angiography (CTA) has become a powerful tool for imaging the vascular system. We compare conventional angiography to CTA in the diagnosis of morphological changes in the abdominal aorta and its branches. A retrospective analysis of 52 patients who underwent both multislice CT angiography (MSCTA) and digital subtraction angiography before surgical treatment is presented. All CT examinations were performed after administration of 100 mL contrast medium with a collimation of 4 x 1 mm and a pitch of 7. A standardized evaluation of the axial, multiplanar and 3D reconstructions was performed by two experienced radiologists. Stenoses were classified as high-grade and low-grade, and aneurysms, occlusions and arteriosclerosis were evaluated. The CTA findings were compared with conventional angiography. All aneurysms, occlusions, stenoses and calcifications were diagnosed correctly by CTA in axial and multiplanar projections (sensitivity 1.0; specificity 1.0). The degree of stenosis was overestimated in three cases when using axial projections. Three-dimensional volume-rendered CTA showed a sensitivity of 0.91 for aneurysms, 0.82 for stenoses, 0.75 for occlusions and 0.77 for calcifications. The specificity was 1.0 in all cases. Multislice CT angiography seems to be similar to conventional digital subtraction angiography for abdominal vessels if multiplanar projections are used.
Collapse
|
|
21 |
26 |
22
|
Herz S, Vogel P, Kampf T, Dietrich P, Veldhoen S, Rückert MA, Kickuth R, Behr VC, Bley TA. Magnetic Particle Imaging-Guided Stenting. J Endovasc Ther 2019; 26:512-519. [PMID: 31131684 DOI: 10.1177/1526602819851202] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Purpose:To assess the feasibility of magnetic particle imaging (MPI) to guide stenting in a phantom model. Materials and Methods: MPI is a new tomographic imaging method based on the background-free magnetic field detection of a tracer agent composed of superparamagnetic iron oxide nanoparticles (SPIOs). All experiments were conducted on a custom-built MPI scanner (field of view: 29-mm diameter, 65-mm length; isotropic spatial resolution 1-1.5-mm). Stenosis phantoms (n=3) consisted of polyvinyl chloride (PVC) tubes (8-mm inner diameter) prepared with centrally aligned cable binders to form a ~50% stenosis. A dedicated image reconstruction algorithm allowed precise tracking of endovascular instruments at 8 frames/s with a latency time of ~115 ms. A custom-made MPI-visible lacquer was used to manually label conventional guidewires, balloon catheters, and stainless steel balloon-expandable stents. Vascular stenoses were visualized by injecting a diluted SPIO tracer (ferucarbotran, 10 mmol iron/L) into the vessel phantoms. Balloon angioplasty and stent placement were performed by inflating balloon catheters and stent delivery balloons with diluted ferucarbotran. Results: After deployment of the stent, the markers on its ends were clearly visible. The applied lacquer markers were thin enough to not relevantly alter gliding properties of the devices while withstanding friction during the experiments. Placing an optimized flexible lacquer formulation on the preexisting radiopaque stent markers provided enough stability to withstand stent expansion. Final MPA confirmed successful stenosis treatment, facilitated by the disappearance of the lacquer markers on the stent due to differences in SPIO concentration. Thus, the in-stent lumen could be visualized without interference by the signal from the markers. Conclusion: Near real-time visualization of MPI-guided stenting of stenoses in a phantom model is feasible. Optimized MPI-visible markers can withstand the expansion process of stents.
Collapse
|
Video-Audio Media |
6 |
26 |
23
|
Kickuth R, Laufer U, Hartung G, Gruening C, Stueckle C, Kirchner J. 3D CT versus axial helical CT versus conventional tomography in the classification of acetabular fractures: a ROC analysis. Clin Radiol 2002; 57:140-5. [PMID: 11977949 DOI: 10.1053/crad.2001.0860] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
AIM To assess the diagnostic power of three-dimensional computed tomography (3D CT), axial helical computed tomography (CT) and conventional tomography in the classification of acetabular fractures by interdisciplinary review. MATERIALS AND METHODS Receiver operating characteristics (ROCs) were assessed for two radiologists and two surgeons blinded to the presence of acetabular fractures in an animal model (a total of 62 porcine hips, 40 of them with artificial acetabular fractures). Main target parameter was the diagnostic accuracy in the classification of the artificial fractures following Judet et al. RESULTS ROC analysis for radiologists showed A(z) values of 0.83 for 3D CT, 0.81 for axial helical CT, and 0.78 for conventional tomography; differences between the three techniques were not significant (P = 0.46-0.73). A(z) values for the surgeons were 0.87 for 3D CT, 0.68 for axial helical CT, and 0.60 for conventional tomography; 3D CT was significantly better than axial helical CT (P = 0.01) and conventional tomography (P = 0.001). The differences between axial helical CT and conventional tomography were not significant (P = 0.37). CONCLUSION Acetabular fractures are best classified by 3D CT, followed by axial helical CT and conventional tomography when assessed by surgeons. 3D CT did not provide any additional significant benefit in the classification performed by radiologists.
Collapse
|
Comparative Study |
23 |
24 |
24
|
Diehm N, Kickuth R, Gahl B, Do DD, Schmidli J, Rattunde H, Baumgartner I, Dick F. Intraobserver and interobserver variability of 64-row computed tomography abdominal aortic aneurysm neck measurements. J Vasc Surg 2007; 45:263-8. [PMID: 17264000 DOI: 10.1016/j.jvs.2006.10.004] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2006] [Accepted: 10/04/2006] [Indexed: 11/26/2022]
Abstract
BACKGROUND Integrity of the abdominal aortic aneurysm (AAA) neck is crucial for the long-term success of endovascular AAA repair (EVAR). However, suitable tools for reliable assessment of changes in small aortic volumes are lacking. The purpose of this study was to assess the intraobserver and interobserver variability of software-enhanced 64-row computed tomographic angiography (CTA) AAA neck volume measurements in patients after EVAR. METHODS A total of 25 consecutive patients successfully treated by EVAR underwent 64-row follow-up CTA in 1.5-mm collimation. Manual CTA measurements were performed twice by three blinded and independent readers in random order with at least a 4-week interval between readings. Maximum and minimum transverse aortic neck diameters were measured twice on two different levels within the proximal neck. Volumetry of the proximal aortic neck was performed by using dedicated software. Variability was calculated as 1.96 SD of the mean arithmetic difference according to Bland and Altman. Two-sided and paired t tests were used to compare measurements. P values <.05 were considered to indicate statistical significance. RESULTS Intraobserver agreement was excellent for dedicated aneurysmal neck volumetry, with mean differences of less than 1 mL (P > .05), whereas it was poor for transverse aortic neck diameter measurements (P < .05). However, interobserver variability was statistically significant for both neck volumetry (P < .005) and neck diameter measurements (P < .015). CONCLUSIONS The reliability of dedicated AAA neck volumetry by using 64-row CTA is excellent for serial measurements by individual readers, but not between different readers. Therefore, studies should be performed with aortic neck volumetry by a single experienced reader.
Collapse
|
Journal Article |
18 |
24 |
25
|
Bonel HM, Saar B, Hoppe H, Keo HH, Husmann M, Nikolaou K, Ludwig K, Szucs-Farkas Z, Srivastav S, Kickuth R. MR Angiography of Infrapopliteal Arteries in Patients with Peripheral Arterial Occlusive Disease by Using Gadofosveset at 3.0 T: Diagnostic Accuracy Compared with Selective DSA. Radiology 2009; 253:879-90. [DOI: 10.1148/radiol.2533081627] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
|
16 |
23 |