1
|
Impact of Aperture, Depth, and Acoustic Clutter on the Performance of Coherent Multi-Transducer Ultrasound Imaging. APPLIED SCIENCES-BASEL 2020; 10:7655. [PMID: 33680504 PMCID: PMC7116862 DOI: 10.3390/app10217655] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Transducers with a larger aperture size are desirable in ultrasound imaging to improve resolution and image quality. A coherent multi-transducer ultrasound imaging system (CoMTUS) enables an extended effective aperture through the coherent combination of multiple transducers. In this study, the discontinuous extended aperture created by CoMTUS and its performance for deep imaging and through layered media are investigated by both simulations and experiments. Typical image quality metrics—resolution, contrast and contrast-to-noise ratio—are evaluated and compared with a standard single probe imaging system. Results suggest that the image performance of CoMTUS depends on the relative spatial location of the arrays. The resulting effective aperture significantly improves resolution, while the separation between the arrays may degrade contrast. For a limited gap in the effective aperture (less than a few centimetres), CoMTUS provides benefits to image quality compared to the standard single probe imaging system. Overall, CoMTUS shows higher sensitivity and reduced loss of resolution with imaging depth. In general, CoMTUS imaging performance was unaffected when imaging through a layered medium with different speed of sound values and resolution improved up to 80% at large imaging depths.
Collapse
|
2
|
Optimal Control of SonoVue Microbubbles to Estimate Hydrostatic Pressure. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:557-567. [PMID: 31634833 PMCID: PMC7053253 DOI: 10.1109/tuffc.2019.2948759] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
The measurement of cardiac and aortic pressures enables diagnostic insight into cardiac contractility and stiffness. However, these pressures are currently assessed invasively using pressure catheters. It may be possible to estimate these pressures less invasively by applying microbubble ultrasound contrast agents as pressure sensors. The aim of this study was to investigate the subharmonic response of the microbubble ultrasound contrast agent SonoVue (Bracco Spa, Milan, Italy) at physiological pressures using a static pressure phantom. A commercially available cell culture cassette with Luer connections was used as a static pressure chamber. SonoVue was added to the phantom, and radio frequency data were recorded on the ULtrasound Advanced Open Platform (ULA-OP). The mean subharmonic amplitude over a 40% bandwidth was extracted at 0-200-mmHg hydrostatic pressures, across 1.7-7.0-MHz transmit frequencies and 3.5%-100% maximum scanner acoustic output. The Rayleigh-Plesset equation for single-bubble oscillations and additional hysteresis experiments were used to provide insight into the mechanisms underlying the subharmonic pressure response of SonoVue. The subharmonic amplitude of SonoVue increased with hydrostatic pressure up to 50 mmHg across all transmit frequencies and decreased thereafter. A decreasing microbubble surface tension may drive the initial increase in the subharmonic amplitude of SonoVue with hydrostatic pressure, while shell buckling and microbubble destruction may contribute to the subsequent decrease above 125-mmHg pressure. In conclusion, a practical operating regime that may be applied to estimate cardiac and aortic blood pressures from the subharmonic signal of SonoVue has been identified.
Collapse
|
3
|
Ring Artifact Correction for Phase-Insensitive Ultrasound Computed Tomography. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:513-525. [PMID: 31634829 DOI: 10.1109/tuffc.2019.2948429] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
An algorithm was developed for the correction of ring artifacts in phase-insensitive ultrasound computed tomography attenuation images. Differences in the measurement sensitivity between the ultrasound transducer array elements cause discontinuities in the sinogram which manifest as rings and arcs in the reconstructed image. The magnitudes of the discontinuities are potentially time-varying and dependent on the attenuation being measured. The algorithm dynamically determines the measurement sensitivity of each transducer in the array during the scan by comparison with both the elements to its left and the elements to its right. Elements at either end of the array are corrected, assuming a zero-attenuation path. The two estimates of sensitivity are combined using a weighted mean similar to a Kalman filter. The algorithm was tested on simulated and experimentally acquired data. It was demonstrated to reduce the root-mean-square error (RMSE) of simulated images against ground-truth images by up to a factor of 50 compared with uncorrected images and to visibly reduce artifacts on images reconstructed from the experimentally acquired data.
Collapse
|
4
|
3-D Super-Resolution Ultrasound Imaging With a 2-D Sparse Array. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:269-277. [PMID: 31562080 PMCID: PMC7614008 DOI: 10.1109/tuffc.2019.2943646] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
High-frame-rate 3-D ultrasound imaging technology combined with super-resolution processing method can visualize 3-D microvascular structures by overcoming the diffraction-limited resolution in every spatial direction. However, 3-D super-resolution ultrasound imaging using a full 2-D array requires a system with a large number of independent channels, the design of which might be impractical due to the high cost, complexity, and volume of data produced. In this study, a 2-D sparse array was designed and fabricated with 512 elements chosen from a density-tapered 2-D spiral layout. High-frame-rate volumetric imaging was performed using two synchronized ULA-OP 256 research scanners. Volumetric images were constructed by coherently compounding nine-angle plane waves acquired at a pulse repetition frequency of 4500 Hz. Localization-based 3-D super-resolution images of two touching subwavelength tubes were generated from 6000 volumes acquired in 12 s. Finally, this work demonstrates the feasibility of 3-D super-resolution imaging and super-resolved velocity mapping using a customized 2-D sparse array transducer.
Collapse
|
5
|
High-Frame-Rate Tri-Plane Echocardiography With Spiral Arrays: From Simulation to Real-Time Implementation. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:57-69. [PMID: 31514130 DOI: 10.1109/tuffc.2019.2940289] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Major cardiovascular diseases (CVDs) are associated with (regional) dysfunction of the left ventricle. Despite the 3-D nature of the heart and its dynamics, the assessment of myocardial function is still largely based on 2-D ultrasound imaging, thereby making diagnosis heavily susceptible to the operator's expertise. Unfortunately, to date, 3-D echocardiography cannot provide adequate spatiotemporal resolution in real-time. Hence, tri-plane imaging has been introduced as a compromise between 2-D and true volumetric ultrasound imaging. However, tri-plane imaging typically requires high-end ultrasound systems equipped with fully populated matrix array probes embedded with expensive and little flexible electronics for two-stage beamforming. This article presents an advanced ultrasound system for real-time, high frame rate (HFR), and tri-plane echocardiography based on low element count sparse arrays, i.e., the so-called spiral arrays. The system was simulated, experimentally validated, and implemented for real-time operation on the ULA-OP 256 system. Five different array configurations were tested together with four different scan sequences, including multi-line and planar diverging wave transmission. In particular, the former can be exploited to achieve, in tri-plane imaging, the same temporal resolution currently used in clinical 2-D echocardiography, at the expenses of contrast (-3.5 dB) and signal-to-noise ratio (SNR) (-8.7 dB). On the other hand, the transmission of planar diverging waves boosts the frame rate up to 250 Hz, but further compromises contrast (-10.5 dB), SNR (-9.7 dB), and lateral resolution (+46%). In conclusion, despite an unavoidable loss in image quality and sensitivity due to the limited number of elements, HFR tri-plane imaging with spiral arrays is shown to be feasible in real-time and may enable real-time functional analysis of all left ventricular segments of the heart.
Collapse
|
6
|
Coherent Multi-Transducer Ultrasound Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:1316-1330. [PMID: 31180847 PMCID: PMC7115943 DOI: 10.1109/tuffc.2019.2921103] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
This work extends the effective aperture size by coherently compounding the received radio frequency data from multiple transducers. As a result, it is possible to obtain an improved image, with enhanced resolution, an extended field of view (FoV), and high-acquisition frame rates. A framework is developed in which an ultrasound imaging system consisting of N synchronized matrix arrays, each with partly shared FoV, take turns to transmit plane waves (PWs). Only one individual transducer transmits at each time while all N transducers simultaneously receive. The subwavelength localization accuracy required to combine information from multiple transducers is achieved without the use of any external tracking device. The method developed in this study is based on the study of the backscattered echoes received by the same transducer and resulting from a targeted scatterer point in the medium insonated by the multiple ultrasound probes of the system. The current transducer locations along with the speed of sound in the medium are deduced by optimizing the cross correlation between these echoes. The method is demonstrated experimentally in 2-D for two linear arrays using point targets and anechoic lesion phantoms. The first demonstration of a free-hand experiment is also shown. Results demonstrate that the coherent multi-transducer ultrasound imaging method has the potential to improve ultrasound image quality, improving resolution, and target detectability. Compared with coherent PW compounding using a single probe, lateral resolution improved from 1.56 to 0.71 mm in the coherent multi-transducer imaging method without acquisition frame rate sacrifice (acquisition frame rate 5350 Hz).
Collapse
|
7
|
Poisson Statistical Model of Ultrasound Super-Resolution Imaging Acquisition Time. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:1246-1254. [PMID: 31107645 PMCID: PMC7614131 DOI: 10.1109/tuffc.2019.2916603] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
A number of acoustic super-resolution techniques have recently been developed to visualize microvascular structure and flow beyond the diffraction limit. A crucial aspect of all ultrasound (US) super-resolution (SR) methods using single microbubble localization is time-efficient detection of individual bubble signals. Due to the need for bubbles to circulate through the vasculature during acquisition, slow flows associated with the microcirculation limit the minimum acquisition time needed to obtain adequate spatial information. Here, a model is developed to investigate the combined effects of imaging parameters, bubble signal density, and vascular flow on SR image acquisition time. We find that the estimated minimum time needed for SR increases for slower blood velocities and greater resolution improvement. To improve SR from a resolution of λ /10 to λ /20 while imaging the microvasculature structure modeled here, the estimated minimum acquisition time increases by a factor of 14. The maximum useful imaging frame rate to provide new spatial information in each image is set by the bubble velocity at low blood flows (<150 mm/s for a depth of 5 cm) and by the acoustic wave velocity at higher bubble velocities. Furthermore, the image acquisition procedure, transmit frequency, localization precision, and desired super-resolved image contrast together determine the optimal acquisition time achievable for fixed flow velocity. Exploring the effects of both system parameters and details of the target vasculature can allow a better choice of acquisition settings and provide improved understanding of the completeness of SR information.
Collapse
|
8
|
Abstract
Background Variations in lymph node (LN) microcirculation can be indicative of metastasis. The identification and quantification of metastatic LNs remains essential for prognosis and treatment planning, but a reliable noninvasive imaging technique is lacking. Three-dimensional super-resolution (SR) US has shown potential to noninvasively visualize microvascular networks in vivo. Purpose To study the feasibility of three-dimensional SR US imaging of rabbit LN microvascular structure and blood flow by using microbubbles. Materials and Methods In vivo studies were carried out to image popliteal LNs of two healthy male New Zealand white rabbits aged 6-8 weeks. Three-dimensional, high-frame-rate, contrast material-enhanced US was achieved by mechanically scanning with a linear imaging probe. Individual microbubbles were identified, localized, and tracked to form three-dimensional SR images and super-resolved velocity maps. Acoustic subaperture processing was used to improve image contrast and to generate enhanced power Doppler and color Doppler images. Vessel size and blood flow velocity distributions were evaluated and assessed by using Student paired t test. Results SR images revealed microvessels in the rabbit LN, with branches clearly resolved when separated by 30 µm, which is less than half of the acoustic wavelength and not resolvable by using power or color Doppler. The apparent size distribution of most vessels in the SR images was below 80 µm and agrees with micro-CT data, whereas most of those detected with Doppler techniques were larger than 80 µm in the images. The blood flow velocity distribution indicated that most of the blood flow in rabbit popliteal LN was at velocities lower than 5 mm/sec. Conclusion Three-dimensional super-resolution US imaging using microbubbles allows noninvasive nonionizing visualization and quantification of lymph node microvascular structures and blood flow dynamics with resolution below the wave diffraction limit. This technology has potential for studying the physiologic functions of the lymph system and for clinical detection of lymph node metastasis. Published under a CC BY 4.0 license. Online supplemental material is available for this article.
Collapse
|
9
|
Investigation of Microbubble Detection Methods for Super-Resolution Imaging of Microvasculature. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:676-691. [PMID: 30676955 DOI: 10.1109/tuffc.2019.2894755] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Ultrasound super-resolution techniques use the response of microbubble (MB) contrast agents to visualize the microvasculature. Techniques that localize isolated bubble signals first require detection algorithms to separate the MB and tissue responses. This work explores the three main MB detection techniques for super-resolution of microvasculature. Pulse inversion (PI), differential imaging (DI), and singular value decomposition (SVD) filtering were compared in terms of the localization accuracy, precision, and contrast-to-tissue ratio. MB responses were simulated based on the properties of Sonovue and using the Marmottant model. Nonlinear propagation through tissue was modeled using the k-Wave software package. For the parameters studied, the results show that PI is most appropriate for low frequency applications, but also most dependent on transducer bandwidth. SVD is preferable for high frequency acquisition where localization precision on the order of a few microns is possible. PI is largely independent of flow direction and speed compared to SVD and DI, so is appropriate for visualizing the slowest flows and tortuous vasculature. SVD is unsuitable for stationary MBs and can introduce a localization error on the order of hundreds of microns over the speed range 0-2 mm/s and flow directions from lateral (parallel to probe) to axial (perpendicular to probe). DI is only suitable for flow rates >0.5 mm/s or as flow becomes more axial. Overall, this study develops an MB and tissue nonlinear simulation platform to improve understanding of how different MB detection techniques can impact the super-resolution process and explores some of the factors influencing the suitability of each.
Collapse
|
10
|
Fast Acoustic Wave Sparsely Activated Localization Microscopy (fast-AWSALM): Ultrasound Super-Resolution using Plane-Wave Activation of Nanodroplets. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:1039-1046. [PMID: 30908211 DOI: 10.1109/tuffc.2019.2906496] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Localization-based ultrasound super-resolution imaging using microbubble contrast agents and phase-change nano-droplets has been developed to visualize microvascular structures beyond the diffraction limit. However, the long data acquisition time makes the clinical translation more challenging. In this study, fast acoustic wave sparsely activated localization microscopy (fast-AWSALM) was developed to achieve super-resolved frames with sub-second temporal resolution, by using low-boiling-point octafluoropropane nanodroplets and high frame rate plane waves for activation, destruction, as well as imaging. Fast-AWSALM was demonstrated on an in vitro microvascular phantom to super-resolve structures that could not be resolved by conventional B-mode imaging. The effects of the temperature and mechanical index on fast-AWSALM was investigated. Experimental results show that sub-wavelength micro-structures as small as 190 lm were resolvable in 200 ms with plane-wave transmission at a center frequency of 3.5 MHz and a pulse repetition frequency of 5000 Hz. This is about a 3.5 fold reduction in point spread function full-width-half-maximum compared to that measured in conventional B-mode, and two orders of magnitude faster than the recently reported AWSALM under a non-flow/very slow flow situations and other localization based methods. Just as in AWSALM, fast-AWSALM does not require flow, as is required by current microbubble based ultrasound super resolution techniques. In conclusion, this study shows the promise of fast-AWSALM, a super-resolution ultrasound technique using nanodroplets, which can generate super-resolution images in milli-seconds and does not require flow.
Collapse
|
11
|
3-D Motion Correction for Volumetric Super-Resolution Ultrasound Imaging. IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM : [PROCEEDINGS]. IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM 2019; 2018. [PMID: 34093969 DOI: 10.1109/ultsym.2018.8580145] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Motion during image acquisition can cause image degradation in all medical imaging modalities. This is particularly relevant in 2-D ultrasound imaging, since out-of-plane motion can only be compensated for movements smaller than elevational beamwidth of the transducer. Localization based super-resolution imaging creates even a more challenging motion correction task due to the requirement of a high number of acquisitions to form a single super-resolved frame. In this study, an extension of two-stage motion correction method is proposed for 3-D motion correction. Motion estimation was performed on high volumetric rate ultrasound acquisitions with a handheld probe. The capability of the proposed method was demonstrated with a 3-D microvascular flow simulation to compensate for handheld probe motion. Results showed that two-stage motion correction method reduced the average localization error from 136 to 18 μm.
Collapse
|
12
|
Motion Artifacts and Correction in Multipulse High-Frame Rate Contrast-Enhanced Ultrasound. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:417-420. [PMID: 30571621 DOI: 10.1109/tuffc.2018.2887164] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
High-frame-rate (HFR) ultrasound (US) imaging and contrast-enhanced US (CEUS) are often implemented using multipulse transmissions, to enhance image quality. Multipulse approaches, however, suffer from degradation in the presence of motion, especially when coherent compounding and CEUS are combined. In this paper, we investigate this effect on the intensity of HFR CEUS in deep tissue imaging using simulations and in vivo contrast echocardiography (CE). The simulation results show that the motion artifact is much higher when the flow is in an axial direction than a lateral direction. Using a pulse repetition frequency suitable for cardiac imaging, a motion of 35 cm/s can cause as much as 28.5 dB decrease in image intensity, where compounding can contribute up to 18.7 dB of intensity decrease (11 angles). These motion effects are also demonstrated for in vivo cardiac HFR CE, where the large velocities of both the myocardium and the blood are present. Intensity reductions of 10.4 dB are readily visible in the chamber. Finally, we demonstrate how performing motion-correction before pulse inversion compounding greatly reduces such motion artifact and improve image signal-to-noise ratio and contrast.
Collapse
|
13
|
High-Frame-Rate Contrast Echocardiography Using Diverging Waves: Initial In Vitro and In Vivo Evaluation. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:2212-2221. [PMID: 30028698 DOI: 10.1109/tuffc.2018.2856756] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Contrast echocardiography (CE) ultrasound with microbubble contrast agents has significantly advanced our capability for assessment of cardiac function, including myocardium perfusion quantification. However, in standard CE techniques obtained with line by line scanning, the frame rate and image quality are limited. Recent research has shown significant frame-rate improvement in noncontrast cardiac imaging. In this work, we present and initially evaluate, both in vitro and in vivo, a high-frame-rate (HFR) CE imaging system using diverging waves and pulse inversion sequence. An imaging frame rate of 5500 frames/s before and 250 frames/s after compounding is achieved. A destruction-replenishment sequence has also been developed. The developed HFR CE is compared with standard CE in vitro on a phantom and then in vivo on a sheep heart. The image signal-to-noise ratio and contrast between the myocardium and the chamber are evaluated. The results show up to 13.4-dB improvement in contrast for HFR CE over standard CE when compared at the same display frame rate even when the average spatial acoustic pressure in HFR CE is 36% lower than the standard CE. It is also found that when coherent compounding is used, the HFR CE image intensity can be significantly modulated by the flow motion in the chamber.
Collapse
|
14
|
Two-Stage Motion Correction for Super-Resolution Ultrasound Imaging in Human Lower Limb. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:803-814. [PMID: 29733283 DOI: 10.1109/tuffc.2018.2824846] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
The structure of microvasculature cannot be resolved using conventional ultrasound (US) imaging due to the fundamental diffraction limit at clinical US frequencies. It is possible to overcome this resolution limitation by localizing individual microbubbles through multiple frames and forming a superresolved image, which usually requires seconds to minutes of acquisition. Over this time interval, motion is inevitable and tissue movement is typically a combination of large- and small-scale tissue translation and deformation. Therefore, super-resolution (SR) imaging is prone to motion artifacts as other imaging modalities based on multiple acquisitions are. This paper investigates the feasibility of a two-stage motion estimation method, which is a combination of affine and nonrigid estimation, for SR US imaging. First, the motion correction accuracy of the proposed method is evaluated using simulations with increasing complexity of motion. A mean absolute error of 12.2 was achieved in simulations for the worst-case scenario. The motion correction algorithm was then applied to a clinical data set to demonstrate its potential to enable in vivo SR US imaging in the presence of patient motion. The size of the identified microvessels from the clinical SR images was measured to assess the feasibility of the two-stage motion correction method, which reduced the width of the motion-blurred microvessels to approximately 1.5-fold.
Collapse
|
15
|
Power Doppler Quantification in Assessing Gestational Trophoblastic Neoplasia. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2018; 39:206-212. [PMID: 27529457 DOI: 10.1055/s-0041-111065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
PURPOSE The FIGO score cannot accurately stratify low-risk gestational trophoblastic neoplasia (GTN) patients who develop chemoresistance to single agent methotrexate chemotherapy. Tumour vascularisation is a key risk factor and its quantification may provide non-invasive way of complementing risk assessment. MATERIALS AND METHODS 187 FIGO-staged, low-risk GTN patients were prospectively recruited. Power Doppler ultrasound was analysed using a quantification program. Four diagnostic indicators were obtained comprising the number of colour pixels (NCP), mean dB, power Doppler quantification (PDQ), and percentage of colour pixels (%CP). Each indicator performance was assessed to determine if they could distinguish the subset of low-risk patients who became chemoresistant. RESULTS There were 111 non-resistant and 76 resistant patients. NCP performed best at distinguishing these two groups where the non-resistant group had an average 3435 (± 2060) pixels and the resistant group 6151 (± 3192) pixels (p < 0.001). PDQ and %CP showed significant differences (p < 0.001) but had poorer performance (area under ROC curves were 72 % and 67 % respectively compared with 75 % for NCP). The mean dB index was not significantly different (p = 0.133). CONCLUSION Power Doppler ultrasound quantification shows potential for non-invasive assessment of tumour vascularity and can distinguish low-risk GTN patients who become chemoresistant from those who have an uncomplicated course with first line treatment.
Collapse
|
16
|
High Frame-Rate Contrast Echocardiography: In-Human Demonstration. JACC Cardiovasc Imaging 2017; 11:923-924. [PMID: 29248652 DOI: 10.1016/j.jcmg.2017.09.011] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2017] [Revised: 09/15/2017] [Accepted: 09/21/2017] [Indexed: 11/29/2022]
|
17
|
Microbubble Axial Localization Errors in Ultrasound Super-Resolution Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:1644-1654. [PMID: 28829309 DOI: 10.1109/tuffc.2017.2741067] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Acoustic super-resolution imaging has allowed the visualization of microvascular structure and flow beyond the diffraction limit using standard clinical ultrasound systems through the localization of many spatially isolated microbubble signals. The determination of each microbubble position is typically performed by calculating the centroid, finding a local maximum, or finding the peak of a 2-D Gaussian function fit to the signal. However, the backscattered signal from a microbubble depends not only on diffraction characteristics of the waveform, but also on the microbubble behavior in the acoustic field. Here, we propose a new axial localization method by identifying the onset of the backscattered signal. We compare the accuracy of localization methods using in vitro experiments performed at 7-cm depth and 2.3-MHz center frequency. We corroborate these findings with simulation results based on the Marmottant model. We show experimentally and in simulations that detecting the onset of the returning signal provides considerably increased accuracy for super-resolution. Resulting experimental cross-sectional profiles in super-resolution images demonstrate at least 5.8 times improvement in contrast ratio and more than 1.8 times reduction in spatial spread (provided by 90% of the localizations) for the onset method over centroiding, peak detection, and 2-D Gaussian fitting methods. Simulations estimate that these latter methods could create errors in relative bubble positions as high as at these experimental settings, while the onset method reduced the interquartile range of these errors by a factor of over 2.2. Detecting the signal onset is, therefore, expected to considerably improve the accuracy of super-resolution.
Collapse
|
18
|
3-D In Vitro Acoustic Super-Resolution and Super-Resolved Velocity Mapping Using Microbubbles. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:1478-1486. [PMID: 28767367 DOI: 10.1109/tuffc.2017.2731664] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Standard clinical ultrasound (US) imaging frequencies are unable to resolve microvascular structures due to the fundamental diffraction limit of US waves. Recent demonstrations of 2-D super-resolution both in vitro and in vivo have demonstrated that fine vascular structures can be visualized using acoustic single bubble localization. Visualization of more complex and disordered 3-D vasculature, such as that of a tumor, requires an acquisition strategy which can additionally localize bubbles in the elevational plane with high precision in order to generate super-resolution in all three dimensions. Furthermore, a particular challenge lies in the need to provide this level of visualization with minimal acquisition time. In this paper, we develop a fast, coherent US imaging tool for microbubble localization in 3-D using a pair of US transducers positioned at 90°. This allowed detection of point scatterer signals in 3-D with average precisions equal to [Formula: see text] in axial and elevational planes, and [Formula: see text] in the lateral plane, compared to the diffraction limited point spread function full-widths at half-maximum of 488, 1188, and [Formula: see text] of the original imaging system with a single transducer. Visualization and velocity mapping of 3-D in vitro structures was demonstrated far beyond the diffraction limit. The capability to measure the complete flow pattern of blood vessels associated with disease at depth would ultimately enable analysis of in vivo microvascular morphology, blood flow dynamics, and occlusions resulting from disease states.
Collapse
|
19
|
A Temporal and Spatial Analysis Approach to Automated Segmentation of Microbubble Signals in Contrast-Enhanced Ultrasound Images: Application to Quantification of Active Vascular Density in Human Lower Limbs. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:2221-2234. [PMID: 28693905 DOI: 10.1016/j.ultrasmedbio.2017.05.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2016] [Revised: 05/17/2017] [Accepted: 05/21/2017] [Indexed: 06/07/2023]
Abstract
Contrast-enhanced ultrasound (CEUS) using microbubble contrast agents has shown great promise in visualising and quantifying active vascular density. Most existing approaches for vascular density quantification using CEUS are calculated based on image intensity and are susceptible to confounding factors and imaging artefact. Poor reproducibility is a key challenge to clinical translation. In this study, a new automated temporal and spatial signal analysis approach is developed for reproducible microbubble segmentation and quantification of contrast enhancement in human lower limbs. The approach is evaluated in vitro on phantoms and in vivo in lower limbs of healthy volunteers before and after physical exercise. In this approach, vascular density is quantified based on the relative areas microbubbles occupy instead of their image intensity. Temporal features of the CEUS image sequences are used to identify pixels that contain microbubble signals. A microbubble track density (MTD) measure, the ratio of the segmented microbubble area to the whole tissue area, is calculated as a surrogate for active capillary density. In vitro results reveal a good correlation (r2 = 0.89) between the calculated MTD measure and the known bubble concentration. For in vivo results, a significant increase (129% in average) in the MTD measure is found in lower limbs of healthy volunteers after exercise, with excellent repeatability over a series of days (intra-class correlation coefficient = 0.96). This compares to the existing state-of-the-art approach of destruction and replenishment analysis on the same patients (intra-class correlation coefficient ≤0.78). The proposed new approach shows great potential as an accurate and highly reproducible clinical tool for quantification of active vascular density.
Collapse
|
20
|
Characterization of Contrast Agent Microbubbles for Ultrasound Imaging and Therapy Research. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:232-251. [PMID: 27810805 DOI: 10.1109/tuffc.2016.2613991] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
The high efficiency with which gas microbubbles can scatter ultrasound compared with the surrounding blood pool or tissues has led to their widespread employment as contrast agents in ultrasound imaging. In recent years, their applications have been extended to include super-resolution imaging and the stimulation of localized bio-effects for therapy. The growing exploitation of contrast agents in ultrasound and in particular these recent developments have amplified the need to characterize and fully understand microbubble behavior. The aim in doing so is to more fully exploit their utility for both diagnostic imaging and potential future therapeutic applications. This paper presents the key characteristics of microbubbles that determine their efficacy in diagnostic and therapeutic applications and the corresponding techniques for their measurement. In each case, we have presented information regarding the methods available and their respective strengths and limitations, with the aim of presenting information relevant to the selection of appropriate characterization methods. First, we examine methods for determining the physical properties of microbubble suspensions and then techniques for acoustic characterization of both suspensions and single microbubbles. The next section covers characterization of microbubbles as therapeutic agents, including as drug carriers for which detailed understanding of their surface characteristics and drug loading capacity is required. Finally, we discuss the attempts that have been made to allow comparison across the methods employed by various groups to characterize and describe their microbubble suspensions and promote wider discussion and comparison of microbubble behavior.
Collapse
|
21
|
Flow Velocity Mapping Using Contrast Enhanced High-Frame-Rate Plane Wave Ultrasound and Image Tracking: Methods and Initial in Vitro and in Vivo Evaluation. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:2913-2925. [PMID: 26275971 DOI: 10.1016/j.ultrasmedbio.2015.06.012] [Citation(s) in RCA: 60] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2014] [Revised: 04/22/2015] [Accepted: 06/16/2015] [Indexed: 06/04/2023]
Abstract
Ultrasound imaging is the most widely used method for visualising and quantifying blood flow in medical practice, but existing techniques have various limitations in terms of imaging sensitivity, field of view, flow angle dependence, and imaging depth. In this study, we developed an ultrasound imaging velocimetry approach capable of visualising and quantifying dynamic flow, by combining high-frame-rate plane wave ultrasound imaging, microbubble contrast agents, pulse inversion contrast imaging and speckle image tracking algorithms. The system was initially evaluated in vitro on both straight and carotid-mimicking vessels with steady and pulsatile flows and in vivo in the rabbit aorta. Colour and spectral Doppler measurements were also made. Initial flow mapping results were compared with theoretical prediction and reference Doppler measurements and indicate the potential of the new system as a highly sensitive, accurate, angle-independent and full field-of-view velocity mapping tool capable of tracking and quantifying fast and dynamic flows.
Collapse
|
22
|
Correction of Non-Linear Propagation Artifact in Contrast-Enhanced Ultrasound Imaging of Carotid Arteries: Methods and in Vitro Evaluation. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:1938-1947. [PMID: 25935597 DOI: 10.1016/j.ultrasmedbio.2015.03.014] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2014] [Revised: 03/06/2015] [Accepted: 03/11/2015] [Indexed: 06/04/2023]
Abstract
Non-linear propagation of ultrasound creates artifacts in contrast-enhanced ultrasound images that significantly affect both qualitative and quantitative assessments of tissue perfusion. This article describes the development and evaluation of a new algorithm to correct for this artifact. The correction is a post-processing method that estimates and removes non-linear artifact in the contrast-specific image using the simultaneously acquired B-mode image data. The method is evaluated on carotid artery flow phantoms with large and small vessels containing microbubbles of various concentrations at different acoustic pressures. The algorithm significantly reduces non-linear artifacts while maintaining the contrast signal from bubbles to increase the contrast-to-tissue ratio by up to 11 dB. Contrast signal from a small vessel 600 μm in diameter buried in tissue artifacts before correction was recovered after the correction.
Collapse
|
23
|
Attenuation Correction and Normalisation for Quantification of Contrast Enhancement in Ultrasound Images of Carotid Arteries. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:1876-1883. [PMID: 25843515 DOI: 10.1016/j.ultrasmedbio.2015.02.010] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2014] [Revised: 12/15/2014] [Accepted: 02/21/2015] [Indexed: 06/04/2023]
Abstract
An automated attenuation correction and normalisation algorithm was developed to improve the quantification of contrast enhancement in ultrasound images of carotid arteries. The algorithm first corrects attenuation artefact and normalises intensity within the contrast agent-filled lumen and then extends the correction and normalisation to regions beyond the lumen. The algorithm was first validated on phantoms consisting of contrast agent-filled vessels embedded in tissue-mimicking materials of known attenuation. It was subsequently applied to in vivo contrast-enhanced ultrasound (CEUS) images of human carotid arteries. Both in vitro and in vivo results indicated significant reduction in the shadowing artefact and improved homogeneity within the carotid lumens after the correction. The error in quantification of microbubble contrast enhancement caused by attenuation on phantoms was reduced from 55% to 5% on average. In conclusion, the proposed method exhibited great potential in reducing attenuation artefact and improving quantification in contrast-enhanced ultrasound of carotid arteries.
Collapse
|
24
|
Dual shear wave induced laser speckle contrast signal and the improvement in shear wave speed measurement. BIOMEDICAL OPTICS EXPRESS 2015; 6:1954-62. [PMID: 26114021 PMCID: PMC4473736 DOI: 10.1364/boe.6.001954] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/07/2015] [Revised: 02/24/2015] [Accepted: 02/25/2015] [Indexed: 05/04/2023]
Abstract
Shear wave speed is quantitatively related to tissue viscoelasticity. Previously we reported shear wave tracking at centimetre depths in a turbid optical medium using laser speckle contrast detection. Shear wave progression modulates displacement of optical scatterers and therefore modulates photon phase and changes the laser speckle patterns. Time-resolved charge-coupled device (CCD)-based speckle contrast analysis was used to track shear waves and measure the time-of-flight of shear waves for speed measurement. In this manuscript, we report a new observation of the laser speckle contrast difference signal for dual shear waves. A modulation of CCD speckle contrast difference was observed and simulation reproduces the modulation pattern, suggesting its origin. Both experimental and simulation results show that the dual shear wave approach generates an improved definition of temporal features in the time-of-flight optical signal and an improved signal to noise ratio with a standard deviation less than 50% that of individual shear waves. Results also show that dual shear waves can correct the bias of shear wave speed measurement caused by shear wave reflections from elastic boundaries.
Collapse
|
25
|
Quantifying activation of perfluorocarbon-based phase-change contrast agents using simultaneous acoustic and optical observation. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:1422-31. [PMID: 25656747 PMCID: PMC5706456 DOI: 10.1016/j.ultrasmedbio.2014.12.021] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2014] [Revised: 12/01/2014] [Accepted: 12/15/2014] [Indexed: 05/05/2023]
Abstract
Phase-change contrast agents in the form of nanoscale droplets can be activated into microbubbles by ultrasound, extending the contrast beyond the vasculature. This article describes simultaneous optical and acoustical measurements for quantifying the ultrasound activation of phase-change contrast agents over a range of concentrations. In experiments, decafluorobutane-based nanodroplets of different dilutions were sonicated with a high-pressure activation pulse and two low-pressure interrogation pulses immediately before and after the activation pulse. The differences between the pre- and post-interrogation signals were calculated to quantify the acoustic power scattered by the microbubbles activated over a range of droplet concentrations. Optical observation occurred simultaneously with the acoustic measurement, and the pre- and post-microscopy images were processed to generate an independent quantitative indicator of the activated microbubble concentration. Both optical and acoustic measurements revealed linear relationships to the droplet concentration at a low concentration range <10(8)/mL when measured at body temperature. Further increases in droplet concentration resulted in saturation of the acoustic interrogation signal. Compared with body temperature, room temperature was found to produce much fewer and larger bubbles after ultrasound droplet activation.
Collapse
|
26
|
Decompression induced bubble dynamics on ex vivo fat and muscle tissue surfaces with a new experimental set up. Colloids Surf B Biointerfaces 2015; 129:121-9. [PMID: 25835147 DOI: 10.1016/j.colsurfb.2015.03.027] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2014] [Revised: 02/17/2015] [Accepted: 03/10/2015] [Indexed: 10/23/2022]
Abstract
Vascular gas bubbles are routinely observed after scuba dives using ultrasound imaging, however the precise formation mechanism and site of these bubbles are still debated and growth from decompression in vivo has not been extensively studied, due in part to imaging difficulties. An experimental set-up was developed for optical recording of bubble growth and density on tissue surface area during hyperbaric decompression. Muscle and fat tissues (rabbits, ex vivo) were covered with nitrogen saturated distilled water and decompression experiments performed, from 3 to 0bar, at a rate of 1bar/min. Pictures were automatically acquired every 5s from the start of the decompression for 1h with a resolution of 1.75μm. A custom MatLab analysis code implementing a circular Hough transform was written and shown to be able to track bubble growth sequences including bubble center, radius, contact line and contact angles over time. Bubble density, nucleation threshold and detachment size, as well as coalescence behavior, were shown significantly different for muscle and fat tissues surfaces, whereas growth rates after a critical size were governed by diffusion as expected. Heterogeneous nucleation was observed from preferential sites on the tissue substrate, where the bubbles grow, detach and new bubbles form in turn. No new nucleation sites were observed after the first 10min post decompression start so bubble density did not vary after this point in the experiment. In addition, a competition for dissolved gas between adjacent multiple bubbles was demonstrated in increased delay times as well as slower growth rates for non-isolated bubbles.
Collapse
|
27
|
In vivo acoustic super-resolution and super-resolved velocity mapping using microbubbles. IEEE TRANSACTIONS ON MEDICAL IMAGING 2015; 34:433-40. [PMID: 25265604 DOI: 10.1109/tmi.2014.2359650] [Citation(s) in RCA: 186] [Impact Index Per Article: 20.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
The structure of microvasculature cannot be resolved using standard clinical ultrasound (US) imaging frequencies due to the fundamental diffraction limit of US waves. In this work, we use a standard clinical US system to perform in vivo sub-diffraction imaging on a CD1, female mouse aged eight weeks by localizing isolated US signals from microbubbles flowing within the ear microvasculature, and compare our results to optical microscopy. Furthermore, we develop a new technique to map blood velocity at super-resolution by tracking individual bubbles through the vasculature. Resolution is improved from a measured lateral and axial resolution of 112 μm and 94 μ m respectively in original US data, to super-resolved images of microvasculature where vessel features as fine as 19 μm are clearly visualized. Velocity maps clearly distinguish opposing flow direction and separated speed distributions in adjacent vessels, thereby enabling further differentiation between vessels otherwise not spatially separated in the image. This technique overcomes the diffraction limit to provide a noninvasive means of imaging the microvasculature at super-resolution, to depths of many centimeters. In the future, this method could noninvasively image pathological or therapeutic changes in the microvasculature at centimeter depths in vivo.
Collapse
|
28
|
Detecting tissue optical and mechanical properties with an ultrasound modulated optical imaging system in reflection detection geometry. BIOMEDICAL OPTICS EXPRESS 2015; 6:63-71. [PMID: 25657875 PMCID: PMC4317126 DOI: 10.1364/boe.6.000063] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2014] [Revised: 10/16/2014] [Accepted: 10/20/2014] [Indexed: 06/04/2023]
Abstract
Tissue optical and mechanical properties are correlated to tissue pathologic changes. This manuscript describes a dual-mode ultrasound modulated optical imaging system capable of sensing local optical and mechanical properties in reflection geometry. The optical characterisation was achieved by the acoustic radiation force assisted ultrasound modulated optical tomography (ARF-UOT) with laser speckle contrast detection. Shear waves generated by the ARF were also tracked optically by the same system and the shear wave speed was used for the elasticity measurement. Tissue mimicking phantoms with multiple inclusions buried at 11 mm depth were experimentally scanned with the dual-mode system. The inclusions, with higher optical absorption and/or higher stiffness than background, were identified based on the dual results and their stiffnesses were quantified. The system characterises both optical and mechanical properties of the inclusions compared with the ARF-UOT or the elasticity measurement alone. Moreover, by detecting the backward scattered light in reflection detection geometry, the system is more suitable for clinical applications compared with transmission geometry.
Collapse
|
29
|
Dynamics of targeted microbubble adhesion under pulsatile compared with steady flow. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:2445-2457. [PMID: 25023113 DOI: 10.1016/j.ultrasmedbio.2014.03.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2013] [Revised: 03/05/2014] [Accepted: 03/10/2014] [Indexed: 06/03/2023]
Abstract
Hemodynamic flow variations at low fluid shear stress are thought to play a critical role in local atherosclerotic plaque initiation and development and to affect plaque instability. Targeted microbubbles are being developed as intravascular agents for identifying atherosclerotic lesions using ultrasound. How variations in local hydrodynamic flow influence the adhesiveness of targeted microbubbles is not well understood. We postulated that rates of targeted microbubble binding and accumulation differ when subjected to steady flow (SF) as compared with oscillatory or pulsatile flow (PF), because PF imposes non-uniform blood rheology and periodic acceleration and deceleration of blood velocity, when compared with SF. We assessed the binding rates of targeted microbubbles in seven randomly assigned PF and seven matched SF replicate runs at low (<1 Pa) and intermediate (≥1 and <2.5 Pa) wall shear stress (WSS) by drawing 4.8 × 10(6) microbubbles mL(-1) over streptavidin-coated substrates, immobilized within a parallel plate flow chamber at a calculated density of 81 binding sites μm(-2). Selective binding and accumulation of targeted microbubbles was recorded in a single field of view using real-time video microscopy. Microbubble accumulation was modeled to obtain flow-mediated microbubble binding kinetics (amplitude, A, and rate constant, k). PF elicited higher microbubble accumulation rates, in comparison to SF. The rates of microbubble accumulation differed significantly between PF and SF (p < 0.05) at intermediate WSS but not at low WSS (p > 0.05). The rate of microbubble accumulation decreased as WSS increased.
Collapse
|
30
|
Circulatory bubble dynamics: from physical to biological aspects. Adv Colloid Interface Sci 2014; 206:239-49. [PMID: 24534474 DOI: 10.1016/j.cis.2014.01.017] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2013] [Revised: 01/21/2014] [Accepted: 01/22/2014] [Indexed: 12/21/2022]
Abstract
Bubbles can form in the body during or after decompression from pressure exposures such as those undergone by scuba divers, astronauts, caisson and tunnel workers. Bubble growth and detachment physics then becomes significant in predicting and controlling the probability of these bubbles causing mechanical problems by blocking vessels, displacing tissues, or inducing an inflammatory cascade if they persist for too long in the body before being dissolved. By contrast to decompression induced bubbles whose site of initial formation and exact composition are debated, there are other instances of bubbles in the bloodstream which are well-defined. Gas emboli unwillingly introduced during surgical procedures and ultrasound microbubbles injected for use as contrast or drug delivery agents are therefore also discussed. After presenting the different ways that bubbles can end up in the human bloodstream, the general mathematical formalism related to the physics of bubble growth and detachment from decompression is reviewed. Bubble behavior in the bloodstream is then discussed, including bubble dissolution in blood, bubble rheology and biological interactions for the different cases of bubble and blood composition considered.
Collapse
|
31
|
Prospects for enhancement of targeted radionuclide therapy of cancer using ultrasound. J Labelled Comp Radiopharm 2014; 57:279-84. [PMID: 24347456 DOI: 10.1002/jlcr.3157] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2013] [Accepted: 10/29/2013] [Indexed: 01/18/2023]
Abstract
Ultrasound-mediated drug delivery is a promising means of enhancing delivery, distribution and effectiveness of drugs within tumours. In this review, prospects for exploiting ultrasound to improve the tumour delivery and distribution of radiolabelled antibodies for radioimmunotherapy and to overcome barriers imposed by tumour microenvironment are discussed.
Collapse
|
32
|
Tracking shear waves in turbid medium by light: theory, simulation, and experiment. OPTICS LETTERS 2014; 39:1597-600. [PMID: 24690847 DOI: 10.1364/ol.39.001597] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Shear wave propagation provides rich information for material mechanical characterization, including elasticity and viscosity. This Letter reports tracking of shear wave propagation in turbid media by laser-speckle-contrast analysis. The theory is described, and a Monte Carlo simulation of light shear wave interaction was developed. Simulation and experiments on tissue-mimicking phantoms agree well and show tracking of shear wave at the phantom surface and at depth as well as multiple shear waves interacting within the object. The relationship between speckle contrast value and shear wave amplitude is also investigated.
Collapse
|
33
|
The use of portable 2D echocardiography and 'frame-based' bubble counting as a tool to evaluate diving decompression stress. Diving Hyperb Med 2014; 44:5-13. [PMID: 24687479] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2013] [Accepted: 12/10/2013] [Indexed: 06/03/2023]
Abstract
INTRODUCTION 'Decompression stress' is commonly evaluated by scoring circulating bubble numbers post dive using Doppler or cardiac echography. This information may be used to develop safer decompression algorithms, assuming that the lower the numbers of venous gas emboli (VGE) observed post dive, the lower the statistical risk of decompression sickness (DCS). Current echocardiographic evaluation of VGE, using the Eftedal and Brubakk method, has some disadvantages as it is less well suited for large-scale evaluation of recreational diving profiles. We propose and validate a new 'frame-based' VGE-counting method which offers a continuous scale of measurement. METHODS Nine 'raters' of varying familiarity with echocardiography were asked to grade 20 echocardiograph recordings using both the Eftedal and Brubakk grading and the new 'frame-based' counting method. They were also asked to count the number of bubbles in 50 still-frame images, some of which were randomly repeated. A Wilcoxon Spearman ρ calculation was used to assess test-retest reliability of each rater for the repeated still frames. For the video images, weighted kappa statistics, with linear and quadratic weightings, were calculated to measure agreement between raters for the Eftedal and Brubakk method. Bland-Altman plots and intra-class correlation coefficients were used to measure agreement between raters for the frame-based counting method. RESULTS Frame-based counting showed a better inter-rater agreement than the Eftedal and Brubakk grading, even with relatively inexperienced assessors, and has good intra- and inter-rater reliability. CONCLUSION Frame-based bubble counting could be used to evaluate post-dive decompression stress, and offers possibilities for computer-automated algorithms to allow near-real-time counting.
Collapse
|
34
|
Viscosity measurement based on shear-wave laser speckle contrast analysis. JOURNAL OF BIOMEDICAL OPTICS 2013; 18:121511. [PMID: 24357548 DOI: 10.1117/1.jbo.18.12.121511] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2013] [Accepted: 11/27/2013] [Indexed: 05/20/2023]
Abstract
Tissue viscosity is correlated with tissue pathological changes and provides information for tissue characterization. In this study, we report an optical method to track continuous shear-wave propagation at centimeter depths in an optically turbid medium. Shear-wave attenuation coefficients were measured at multiple frequencies using shear-wave laser speckle contrast analysis (SW-LASCA) to quantitatively estimate tissue viscosity using the Voigt model. Shear waves were generated within tissue-mimicking phantoms by an amplitude-modulated ultrasound (modulation frequency: 100 to 600 Hz) and tracked by time-resolved laser speckle contrast difference received on a charged-coupled device camera. Averaged contrast difference over a selected time window was related to shear-wave amplitude and used to calculate the shear-wave attenuation coefficient. Phantoms of varying viscosities (0.1 and 0.3 Pa s) were studied. Attenuation coefficients for different shear-wave frequencies (100 to 600 Hz) were calculated. Derived viscosity values had a maximum standard deviation of 9%, and these values were consistent with the independent measurements reported in a previous study using nonoptical methods.
Collapse
|
35
|
|
36
|
Ultrasound imaging velocimetry: effect of beam sweeping on velocity estimation. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:1672-1681. [PMID: 23791353 DOI: 10.1016/j.ultrasmedbio.2013.03.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2012] [Revised: 02/03/2013] [Accepted: 03/03/2013] [Indexed: 06/02/2023]
Abstract
As an emerging flow-mapping tool that can penetrate deep into optically opaque media such as human tissue, ultrasound imaging velocimetry has promise in various clinical applications. Previous studies have shown that errors occur in velocity estimation, but the causes have not been well characterised. In this study, the error in velocity estimation resulting from ultrasound beam sweeping in image acquisition is quantitatively investigated. The effects on velocity estimation of the speed and direction of beam sweeping relative to those of the flow are studied through simulation and experiment. The results indicate that a relative error in velocity estimation of up to 20% can be expected. Correction methods to reduce the errors under steady flow conditions are proposed and evaluated. Errors in flow estimation under unsteady flow are discussed.
Collapse
|
37
|
A critical review of physiological bubble formation in hyperbaric decompression. Adv Colloid Interface Sci 2013; 191-192:22-30. [PMID: 23523006 DOI: 10.1016/j.cis.2013.02.002] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2012] [Revised: 02/20/2013] [Accepted: 02/23/2013] [Indexed: 11/15/2022]
Abstract
Bubbles are known to form in the body after scuba dives, even those done well within the decompression model limits. These can sometimes trigger decompression sickness and the dive protocols should therefore aim to limit bubble formation and growth from hyperbaric decompression. Understanding these processes physiologically has been a challenge for decades and there are a number of questions still unanswered. The physics and historical background of this field of study is presented and the latest studies and current developments reviewed. Heterogeneous nucleation is shown to remain the prime candidate for bubble formation in this context. The two main theories to account for micronuclei stability are then to consider hydrophobicity of surfaces or tissue elasticity, both of which could also explain some physiological observations. Finally the modeling relevance of the bubble formation process is discussed, together with that of bubble growth as well as multiple bubble behavior.
Collapse
|
38
|
Single bubble acoustic characterization and stability measurement of adherent microbubbles. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:903-914. [PMID: 23473537 DOI: 10.1016/j.ultrasmedbio.2012.12.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2012] [Revised: 12/10/2012] [Accepted: 12/11/2012] [Indexed: 06/01/2023]
Abstract
This article examines how the acoustic and stability characteristics of single lipid-shelled microbubbles (MBs) change as a result of adherence to a target surface. For individual adherent and non-adherent MBs, the backscattered echo from a narrowband 2-MHz, 90-kPa peak negative pressure interrogation pulse was obtained. These measurements were made in conjunction with an increasing amplitude broadband disruption pulse. It was found that, for the given driving frequency, adherence had little effect on the fundamental response of an MB. Examination of the second harmonic response indicated an increase of the resonance frequency for an adherent MB: resonance radius increasing of 0.3 ± 0.1 μm for an adherent MB. MB stability was seen to be closely related to MB resonance and gave further evidence of a change in the resonance frequency due to adherence.
Collapse
|
39
|
Abstract
An investigation into the effect of clinical ultrasound exposure on adherent microbubbles is described. A flow phantom was constructed in which targeted microbubbles were attached using biotin-streptavidin linkages. Microbubbles were insonated by broadband imaging pulses (centred at 2.25 MHz) over a range of pressures (peak negative pressure (PNP) = 60-375 kPa). Individual adherent bubbles were observed optically and classified as either being isolated or with a single neighbouring bubble. It is found that bubble detachment and deflation are two significant effects, even during low amplitude ultrasound exposure. Specifically, while at very low acoustic pressure (PNP < 75 kPa) 95% of the bubbles were not affected, at medium pressure (151 kPa < P < 225 kPa) 53% of the bubbles detached and at higher pressures (301 kPa < P < 375 kPa) 96% of the bubbles detached. In addition, more than 50% of the bubbles underwent deflation at pressures between 301 and 375 kPa. At pressures between 226 and 300 kPa, more adherent bubbles detached when there was a neighbouring bubble, suggesting the role of multiple scattering and secondary Bjerknes force on bubble detachment. The flow shear, primary and secondary Bjerknes forces exerted on each bubble were calculated and compared to the estimated forces acting on the bubble due to oscillations. The oscillation force is shown to be much higher than other forces. The mechanisms of bubble detachment are discussed.
Collapse
|
40
|
Albumin coated microbubble optimization: custom fabrication and comprehensive characterization. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:1599-1607. [PMID: 22763010 DOI: 10.1016/j.ultrasmedbio.2012.05.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2011] [Revised: 04/26/2012] [Accepted: 05/07/2012] [Indexed: 06/01/2023]
Abstract
Gas microbubbles are used routinely to improve contrast in medical diagnostic imaging. The emerging fields of microbubble-enhanced quantitative imaging and microbubble-enhanced drug delivery have further enhanced the drive toward microbubble characterization and design techniques. The quest to improve efficiency, particularly in the field of drug delivery, presents a requirement to develop methods to manipulate microbubble properties to improve utility. This article presents an investigation in to the feasibility of influencing albumin shelled microbubble properties through the variation of albumin availability during fabrication. Microbubbles were fabricated from albumin suspensions of varying concentration before thorough physical and acoustic characterization. Microbubbles with shells fabricated from a 2% albumin suspension had a greater scattering to attenuation ratio (STAR) than 10% albumin preparations (4.4% and 2.2%, respectively) and approximately double the nonlinear STAR (from 0.7% to 1.5%). The 2% microbubbles also exhibited greater (up to 40%), more violent radial oscillations during high speed imaging than 5% and 10% preparations. The results show that microbubble characteristics can be simply manipulated in the lab and indicate that for a given application this may provide the opportunity to further enhance favorable characteristics.
Collapse
|
41
|
Shear wave elasticity imaging based on acoustic radiation force and optical detection. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:1637-45. [PMID: 22749816 DOI: 10.1016/j.ultrasmedbio.2012.04.022] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2011] [Revised: 04/24/2012] [Accepted: 04/25/2012] [Indexed: 05/20/2023]
Abstract
Tissue elasticity is closely related to the velocity of shear waves within biologic tissue. Shear waves can be generated by an acoustic radiation force and tracked by, e.g., ultrasound or magnetic resonance imaging (MRI) measurements. This has been shown to be able to noninvasively map tissue elasticity in depth and has great potential in a wide range of clinical applications including cancer and cardiovascular diseases. In this study, a highly sensitive optical measurement technique is proposed as an alternative way to track shear waves generated by the acoustic radiation force. A charge coupled device (CCD) camera was used to capture diffuse photons from tissue mimicking phantoms illuminated by a laser source at 532 nm. CCD images were recorded at different delays after the transmission of an ultrasound burst and were processed to obtain the time of flight for the shear wave. A differential measurement scheme involving generation of shear waves at two different positions was used to improve the accuracy and spatial resolution of the system. The results from measurements on both homogeneous and heterogeneous phantoms were compared with measurements from other instruments and demonstrate the feasibility and accuracy of the technique for imaging and quantifying elasticity. The relative error in estimation of shear wave velocity can be as low as 3.3% with a spatial resolution of 2 mm, and increases to 8.8% with a spatial resolution of 1 mm for the medium stiffness phantom. The system is shown to be highly sensitive and is able to track shear waves propagating over several centimetres given the ultrasound excitation amplitude and the phantom material used in this study. It was also found that the reflection of shear waves from boundaries between regions with different elastic properties can cause significant bias in the estimation of elasticity, which also applies to other shear wave tracking techniques. This bias can be reduced at the expense of reduced spatial resolution.
Collapse
|
42
|
Modeling non-spherical oscillations and stability of acoustically driven shelled microbubbles. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2012; 131:4349-4357. [PMID: 22712909 DOI: 10.1121/1.4707479] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The oscillation and destruction of microbubbles under ultrasound excitation form the basis of contrast enhanced ultrasound imaging and microbubble assisted drug and gene delivery. A typical microbubble has a size of a few micrometers and consists of a gas core encapsulated by a shell. These bubbles can be driven into surface mode oscillations, which not only contribute to the measured acoustic signal but can lead to bubble destruction. Existing models of surface model oscillations have not considered the effects of a bubble shell. In this study a model was developed to study the surface mode oscillations in shelled bubbles. The effects of shell viscosity and elasticity on the surface mode oscillations were modeled using a Boussinesq-Scriven approach. Simulation was conducted using the model with various bubble sizes and driving acoustic pressures. The occurrence of surface modes and the number of ultrasound cycles needed for the occurrence were calculated. The simulation results show a significant difference between shelled bubbles and shell free bubbles. The shelled bubbles have reduced surface mode amplitudes and a narrower bubble size range within which these modes develop compared to shell free bubbles. The clinical implications were also discussed.
Collapse
|
43
|
Effect of albumin and dextrose concentration on ultrasound and microbubble mediated gene transfection in vivo. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:1067-1077. [PMID: 22502878 DOI: 10.1016/j.ultrasmedbio.2012.02.020] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2011] [Revised: 02/20/2012] [Accepted: 02/20/2012] [Indexed: 05/31/2023]
Abstract
Ultrasound and microbubble mediated gene transfection has great potential for site-selective, safe gene delivery. Albumin-based microbubbles have shown the greatest transfection efficiency but have not been optimised specifically for this purpose. Additionally, few studies have highlighted desirable properties for transfection specific microbubbles. In this article, microbubbles were made with 2% or 5% (w/v) albumin and 20% or 40% (w/v) dextrose solutions, yielding four distinct bubble types. These were acoustically characterised and their efficiency in transfecting a luciferase plasmid (pGL4.13) into female, CD1 mice myocardia was measured. For either albumin concentration, increasing the dextrose concentration increased scattering, attenuation and resistance to ultrasound, resulting in significantly increased transfection. A significant interaction was noted between albumin and dextrose; 2% albumin bubbles made with 20% dextrose showed the least transfection but the most transfection with 40% dextrose. This trend was seen for both nonlinear scattering and attenuation behaviour but not for resistance to ultrasound or total scatter. We have determined that the attenuation behaviour is an important microbubble characteristic for effective gene transfection using ultrasound. Microbubble behaviour can also be simply controlled by altering the initial ingredients used during manufacture.
Collapse
|
44
|
The influence of gas saturation on microbubble stability. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:1097-1100. [PMID: 22475697 DOI: 10.1016/j.ultrasmedbio.2012.02.008] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2011] [Revised: 02/08/2012] [Accepted: 02/09/2012] [Indexed: 05/31/2023]
Abstract
Accurate acoustic characterisation is an essential component of any experimental investigation concerning the use and development of microbubble contrast agents. It is of increasing importance as applications such as therapy and molecular and quantitative imaging are investigated. Such characterisation is generally conducted in the laboratory in the form of bulk acoustic studies or optical observation of single bubbles using high speed photography in a water tank containing "out-gassed" water. The approach is widely used in acoustics to prevent inaccurate measurements being made due to the presence of gas bubbles settling on instrumentation, however, the term is often used to cover a range of water preparation techniques and the final gas content of the water is not usually stated. This technical note demonstrates the influence of gas content on the stability of microbubble contrast agents and concludes that characterisation should always be conducted in equilibrated, gas-saturated water to ensure accurate and repeatable measurements are made.
Collapse
|
45
|
Theoretical and experimental characterisation of magnetic microbubbles. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:864-875. [PMID: 22480944 DOI: 10.1016/j.ultrasmedbio.2012.01.027] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2011] [Revised: 01/26/2012] [Accepted: 01/27/2012] [Indexed: 05/31/2023]
Abstract
In addition to improving image contrast, microbubbles have shown great potential in molecular imaging and drug/gene delivery. Previous work by the authors showed that considerable improvements in gene transfection efficiency were obtained using microbubbles loaded with magnetic nanoparticles under simultaneous exposure to ultrasound and magnetic fields. The aim of this study was to characterise the effect of nanoparticles on the dynamic and acoustic response of the microbubbles. High-speed video microscopy indicated that the amplitude of oscillation was very similar for magnetic and nonmagnetic microbubbles of the same size for the same ultrasound exposure (0.5 MHz, 100 kPa, 12-cycle pulse) and that this was minimally affected by an imposed magnetic field. The linear scattering to attenuation ratio (STAR) was also similar for suspensions of both bubble types although the nonlinear STAR was ~50% lower for the magnetic microbubbles. Both the video and acoustic data were supported by the results from theoretical modelling.
Collapse
|
46
|
Evaluation of methods for sizing and counting of ultrasound contrast agents. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:834-45. [PMID: 22402020 PMCID: PMC3657178 DOI: 10.1016/j.ultrasmedbio.2012.01.012] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2011] [Revised: 12/31/2011] [Accepted: 01/13/2012] [Indexed: 05/15/2023]
Abstract
A precise, accurate and well documented method for the sizing and counting of microbubbles is essential for all aspects of quantitative microbubble-enhanced ultrasound imaging. The efficacy of (a) electro-impedance volumetric zone sensing (ES) also called a Coulter counter/multisizer; (b) optical microscopy (OM); and (c) laser diffraction (LD), for the sizing and counting of microbubbles was assessed. Microspheres with certified mean diameter and number concentration were used to assess sizing and counting reproducibility (precision) and reliability (accuracy) of ES, OM and LD. SonoVue™ was repeatedly (n = 3) sized and counted to validate ES, OM and LD sizing and counting efficacy. Statistical analyses of intra-method variability for the SonoVue™ mean diameter showed that the best microbubble sizing reproducibility was obtained using OM with a mean diameter sizing variability of 1.1%, compared with a variability of 4.3% for ES and 7.1% for LD. The best microbubble counting reproducibility was obtained using ES with a number concentration variability of 8.3%, compared with a variability of 22.4% for OM and 32% for LD. This study showed that no method is fully suited to both sizing and counting of microbubbles.
Collapse
|
47
|
Ultrasonographic measures of synovitis in an early phase clinical trial: a double-blind, randomised, placebo and comparator controlled phase IIa trial of GW274150 (a selective inducible nitric oxide synthase inhibitor) in rheumatoid arthritis. Clin Exp Rheumatol 2012; 30:254-261. [PMID: 22409880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2011] [Accepted: 10/25/2011] [Indexed: 05/31/2023]
Abstract
OBJECTIVES To test the sensitivity to change of ultrasonographic endpoints in early phase clinical trials in subjects with active rheumatoid arthritis (RA). METHODS A double-blind, placebo and comparator controlled, randomised, two-centre study investigated the effect on synovial thickness and vascularity of 28 days repeat daily oral dosing of 60 mg of the inducible nitric oxide synthase inhibitor GW274150 or 7.5 mg prednisolone in RA. Fifty patients with DAS28 scores ≥4.0 were assigned to 3 treatment arms of 17, 19 and 14 (on placebo, GW274150 and prednisolone respectively). Synovial thickness and vascularity of all 10 metacarpophalangeal joints were assessed by ultrasonography using a semi-quantitative scale at baseline (Day 1), Day 15 and Day 28. Vascularity was also measured quantitatively by power Doppler area. RESULTS At Day 28, the GW274150 group showed a trend towards reduction in synovial thickness compared with placebo, with an adjusted mean decrease of 33% (p=0.072); the prednisolone group decreased significantly by 44% (p=0.011). Similarly, there was a trend to reduced synovial vascularity with GW274150 by 42% compared with placebo (p=0.075); prednisolone resulted in a statistically significant decrease of 55% (p=0.012). There was a 55% decrease in power Doppler area for GW274150, compared with placebo although the result was not statistically significant (p=0.375). Prednisolone 7.5 mg resulted in a highly statistically significant decrease of 95% (p=0.003). CONCLUSIONS This study advocates the use of ultrasonographic measures of metacarpophalangeal joint synovitis as an endpoint for clinical studies assessing therapeutic potential of new compounds in small patient cohorts over 28 days.
Collapse
|
48
|
A comparison of 31P magnetic resonance spectroscopy and microbubble-enhanced ultrasound for characterizing hepatitis c-related liver disease. J Viral Hepat 2011; 18:e530-4. [PMID: 21914073 DOI: 10.1111/j.1365-2893.2011.01455.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
We compared in vivo hepatic (31) P magnetic resonance spectroscopy ((31) P MRS) and hepatic vein transit times (HVTT) using contrast-enhanced ultrasound with a microbubble agent to assess the severity of hepatitis C virus (HCV)-related liver disease. Forty-six patients with biopsy-proven HCV-related liver disease and nine healthy volunteers had (31) P MRS and HVTT performed on the same day. (31) P MR spectra were obtained at 1.5 T. Peak areas were calculated for metabolites, including phosphomonoesters (PME) and phosphodiesters (PDE). Patients also had the microbubble ultrasound contrast agent, Levovist (2 g), injected into an antecubital vein, and time-intensity Doppler ultrasound signals of the right and middle hepatic veins were measured. The HVTT was calculated as the time from injection to a sustained rise in Doppler signal 10% greater than baseline. The shortest times were used for analysis. Based on Ishak histological scoring, there were 15 patients with mild hepatitis, 20 with moderate/severe hepatitis and 11 with cirrhosis. With increasing severity of disease, the PME/PDE ratio was steadily elevated, while the HVTT showed a monotonic decrease. Both imaging modalities could separate patients with cirrhosis from the mild and moderate/severe hepatitis groups. No statistical difference was observed in the accuracy of each test to denote mild, moderate/severe hepatitis and cirrhosis (Fisher's exact test P =1.00). (31) P MRS and HVTT show much promise as noninvasive imaging tests for assessing the severity of chronic liver disease. Both are equally effective and highly sensitive in detecting cirrhosis.
Collapse
|
49
|
Influence of needle gauge on in vivo ultrasound and microbubble-mediated gene transfection. ULTRASOUND IN MEDICINE & BIOLOGY 2011; 37:1531-1537. [PMID: 21741156 DOI: 10.1016/j.ultrasmedbio.2011.05.019] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2010] [Revised: 05/11/2011] [Accepted: 05/16/2011] [Indexed: 05/31/2023]
Abstract
Ultrasound and microbubble-mediated gene transfection are potential tools for safe, site-selective gene therapy. However, preclinical trials have demonstrated a low transfection efficiency that has hindered the progression of the technique to clinical application. In this paper it is shown that simple changes to the method of intravenous injection can lead to an increase in transfection efficiency when using 6-MHz diagnostic ultrasound and the ultrasound contrast agent, SonoVue. By using needles of progressively smaller gauge, i.e., larger internal diameter (ID), from 29 G (ID 0.184 mm) to 25 G (ID 0.31 mm), the transfection of a luciferase plasmid (pGL4.13) was significantly increased threefold in heart-targeted female CD1 mice. In vitro work indicated that the concentration and size distribution of SonoVue were affected by increasing needle gauge. These results suggest that the process of systemic delivery alters the bubble population and adversely affects transfection. This is exacerbated by using high-gauge needles. These findings demonstrate that the needle with the largest possible ID should be used for systemic delivery of microbubbles and genetic material.
Collapse
|
50
|
Effect of bubble shell nonlinearity on ultrasound nonlinear propagation through microbubble populations. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2011; 129:EL76-82. [PMID: 21428471 DOI: 10.1121/1.3544677] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Nonlinear propagation of ultrasound through microbubble populations can generate artifacts and reduce contrast to tissue ratio in ultrasound imaging. The existing propagation model, which underestimates harmonic generation by an order of magnitude, was revised by incorporating a nonlinear constitutive equation for the coating into the description of the microbubble dynamics. Significantly better agreement with experiments was obtained, indicating that coating nonlinearity represents an important contribution to nonlinear propagation of ultrasound in microbubble populations. The results were found to be sensitive to the parameters characterizing the coating nonlinearity and thus accurate measurement of these parameters is required for accurate quantitative predictions.
Collapse
|