1
|
X-ray diagnostics of ECR ion sources-Techniques, results, and challenges. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2022; 93:021102. [PMID: 35232141 DOI: 10.1063/5.0076321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2021] [Accepted: 01/28/2022] [Indexed: 06/14/2023]
Abstract
The high magnetic confinement provided by the minimum-B structure of electron cyclotron resonance ion sources (ECRIS) hosts a non-equilibrium plasma, composed of cold multi-charged ions and hot electrons whose energy can expand up to ≈1 MeV. With a very limited accessibility, the ECR plasma is difficult to study. The x-ray photons generated by the interaction of the warm and hot electron populations within the plasma, as well as the photons generated by electrons lost to the chamber wall, are a signal of great interest as it gives an insight to the properties of the ECR plasma. After an introduction presenting the mechanism generating the x rays in ECRIS, this Review presents the methodology to measure x rays both for volumetric measurements and plasma imaging. The main insights of those measurements are presented. Prospects of x-ray measurements to better understand the plasma dynamics are finally highlighted.
Collapse
|
2
|
X-ray pinhole camera setups used in the Atomki ECR Laboratory for plasma diagnostics. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:02A741. [PMID: 26931959 DOI: 10.1063/1.4933085] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Imaging of the electron cyclotron resonance (ECR) plasmas by using CCD camera in combination with a pinhole is a non-destructive diagnostics method to record the strongly inhomogeneous spatial density distribution of the X-ray emitted by the plasma and by the chamber walls. This method can provide information on the location of the collisions between warm electrons and multiple charged ions/atoms, opening the possibility to investigate the direct effect of the ion source tuning parameters to the plasma structure. The first successful experiment with a pinhole X-ray camera was carried out in the Atomki ECR Laboratory more than 10 years ago. The goal of that experiment was to make the first ECR X-ray photos and to carry out simple studies on the effect of some setting parameters (magnetic field, extraction, disc voltage, gas mixing, etc.). Recently, intensive efforts were taken to investigate now the effect of different RF resonant modes to the plasma structure. Comparing to the 2002 experiment, this campaign used wider instrumental stock: CCD camera with a lead pinhole was placed at the injection side allowing X-ray imaging and beam extraction simultaneously. Additionally, Silicon Drift Detector (SDD) and High Purity Germanium (HPGe) detectors were installed to characterize the volumetric X-ray emission rate caused by the warm and hot electron domains. In this paper, detailed comparison study on the two X-ray camera and detector setups and also on the technical and scientific goals of the experiments is presented.
Collapse
|
3
|
Recent developments of ion sources for life-science studies at the Heavy Ion Medical Accelerator in Chiba (invited). THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:02C107. [PMID: 26932117 DOI: 10.1063/1.4934843] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
With about 1000-h of relativistic high-energy ion beams provided by Heavy Ion Medical Accelerator in Chiba, about 70 users are performing various biology experiments every year. A rich variety of ion species from hydrogen to xenon ions with a dose rate of several Gy/min is available. Carbon, iron, silicon, helium, neon, argon, hydrogen, and oxygen ions were utilized between 2012 and 2014. Presently, three electron cyclotron resonance ion sources (ECRISs) and one Penning ion source are available. Especially, the two frequency heating techniques have improved the performance of an 18 GHz ECRIS. The results have satisfied most requirements for life-science studies. In addition, this improved performance has realized a feasible solution for similar biology experiments with a hospital-specified accelerator complex.
Collapse
|
4
|
Two-chamber configuration of Bio-Nano electron cyclotron resonance ion source for fullerene modification. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:02A720. [PMID: 26931938 DOI: 10.1063/1.4934649] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
We report on the modification of fullerenes with iron and chlorine using two individually controllable plasmas in the Bio-Nano electron cyclotron resonance ion source (ECRIS). One of the plasmas is composed of fullerene and the other one is composed of iron and chlorine. The online ion beam analysis allows one to investigate the rate of the vapor-phase collisional modification process in the ECRIS, while the offline analyses (e.g., liquid chromatography-mass spectrometry) of the materials deposited on the plasma chamber can give information on the surface-type process. Both analytical methods show the presence of modified fullerenes such as fullerene-chlorine, fullerene-iron, and fullerene-chlorine-iron.
Collapse
|
5
|
Ion beam emittance from an ECRIS. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:02A724. [PMID: 26931942 PMCID: PMC4636505 DOI: 10.1063/1.4934210] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2015] [Accepted: 10/08/2015] [Indexed: 06/05/2023]
Abstract
Simulation of ion beam extraction from an Electron Cyclotron Resonance Ion Source (ECRIS) is a fully 3 dimensional problem, even if the extraction geometry has cylindrical symmetry. Because of the strong magnetic flux density, not only the electrons are magnetized but also the Larmor radius of ions is much smaller than the geometrical dimension of the plasma chamber (Ø 64 × 179 mm). If we assume that the influence of collisions is small on the path of particles, we can do particle tracking through the plasma if the initial coordinates of particles are known. We generated starting coordinates of plasma ions by simulation of the plasma electrons, accelerated stochastically by the 14.5 GHz radio frequency power fed to the plasma. With that we were able to investigate the influence of different electron energies on the extracted beam. Using these assumptions, we can reproduce the experimental results obtained 10 years ago, where we monitored the beam profile with the help of viewing targets. Additionally, methods have been developed to investigate arbitrary 2D cuts of the 6D phase space. To this date, we are able to discuss full 4D information. Currently, we extend our analysis tool towards 5D and 6D, respectively.
Collapse
|
6
|
Experiments with biased side electrodes in electron cyclotron resonance ion sources. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:02A921. [PMID: 24593500 DOI: 10.1063/1.4827309] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The output of highly charged ions from an electron cyclotron resonance ion source (ECRIS) consists of ionic losses from a highly confined plasma. Therefore, an increase of the output of the ions of interest always is a compromise between an increase in the confinement and an increase of the losses. One route towards a solution consists of attacking the losses in directions - i.e., radial directions - that do not contribute to the required output. This was demonstrated in an experiment (using the Kei ECRIS at NIRS, Japan) where radial losses were electrostatically reduced by positively biasing one set of six "side" electrodes surrounding the plasma in side-ward directions attached (insulated) to the cylindrical wall of the plasma chamber. Recently new studies were performed in two laboratories using two essentially different ion sources. At the BioNano ECRIS (Toyo University, Japan) various sets of electrodes were used; each of the electrodes could be biased individually. At the Atomki ECRIS (Hungary), one movable, off-axis side electrode was applied in technically two versions. The measurements show indeed a decrease of ionic losses but different effectivities as compared to the biased disk.
Collapse
|
7
|
Synthesis of endohedral iron-fullerenes by ion implantation. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:02A945. [PMID: 24593524 DOI: 10.1063/1.4850756] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
In this paper, we discuss the results of our study of the synthesis of endohedral iron-fullerenes. A low energy Fe(+) ion beam was irradiated to C60 thin film by using a deceleration system. Fe(+)-irradiated C60 thin film was analyzed by high performance liquid chromatography and laser desorption/ ionization time-of-flight mass spectrometry. We investigated the performance of the deceleration system for using a Fe(+) beam with low energy. In addition, we attempted to isolate the synthesized material from a Fe(+)-irradiated C60 thin film by high performance liquid chromatography.
Collapse
|
8
|
Fast camera studies at an electron cyclotron resonance table plasma generator. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:02A507. [PMID: 24593430 DOI: 10.1063/1.4847215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
A simple table-size ECR plasma generator operates in the ATOMKI without axial magnetic trap and without any particle extraction tool. Radial plasma confinement is ensured by a NdFeB hexapole. The table-top ECR is a simplified version of the 14 GHz ATOMKI-ECRIS. Plasma diagnostics experiments are planned to be performed at this device before installing the measurement setting at the "big" ECRIS. Recently, the plasma generator has been operated in pulsed RF mode in order to investigate the time evolution of the ECR plasma in two different ways. (1) The visible light radiation emitted by the plasma was investigated by the frames of a fast camera images with 1 ms temporal resolution. Since the visible light photographs are in strong correlation with the two-dimensional spatial distribution of the cold electron components of the plasma it can be important to understand better the transient processes just after the breakdown and just after the glow. (2) The time-resolved ion current on a specially shaped electrode was measured simultaneously in order to compare it with the visible light photographs. The response of the plasma was detected by changing some external setting parameters (gas pressure and microwave power) and was described in this paper.
Collapse
|
9
|
Two-frequency heating technique at the 18 GHz electron cyclotron resonance ion source of the National Institute of Radiological Sciences. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:02A931. [PMID: 24593510 DOI: 10.1063/1.4829735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The two-frequency heating technique was studied to increase the beam intensities of highly charged ions provided by the high-voltage extraction configuration (HEC) ion source at the National Institute of Radiological Sciences (NIRS). The observed dependences on microwave power and frequency suggested that this technique improved plasma stability but it required precise frequency tuning and more microwave power than was available before 2013. Recently, a new, high-power (1200 W) wide band-width (17.1-18.5 GHz) travelling-wave-tube amplifier (TWTA) was installed. After some single tests with klystron and TWT amplifiers the simultaneous injection of the two microwaves has been successfully realized. The dependence of highly charged ions (HCI) currents on the superposed microwave power was studied by changing only the output power of one of the two amplifiers, alternatively. While operating the klystron on its fixed 18.0 GHz, the frequency of the TWTA was swept within its full limits (17.1-18.5 GHz), and the effect of this frequency on the HCI-production rate was examined under several operation conditions. As an overall result, new beam records of highly charged argon, krypton, and xenon beams were obtained at the NIRS-HEC ion source by this high-power two-frequency operation mode.
Collapse
|
10
|
Status of the Bio-Nano electron cyclotron resonance ion source at Toyo University. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:02C317. [PMID: 24593654 DOI: 10.1063/1.4862212] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
In the paper, the material science experiments, carried out recently using the Bio-Nano electron cyclotron resonance ion source (ECRIS) at Toyo University, are reported. We have investigated several methods to synthesize endohedral C60 using ion-ion and ion-molecule collision reaction in the ECRIS. Because of the simplicity of the configuration, we can install a large choice of additional equipment in the ECRIS. The Bio-Nano ECRIS is suitable not only to test the materials production but also to test technical developments to improve or understand the performance of an ECRIS.
Collapse
|
11
|
Fullerene-rare gas mixed plasmas in an electron cyclotron resonance ion source. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:02A936. [PMID: 24593515 DOI: 10.1063/1.4847255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
A synthesis technology of endohedral fullerenes such as Fe@C60 has developed with an electron cyclotron resonance (ECR) ion source. The production of N@C60 was reported. However, the yield was quite low, since most fullerene molecules were broken in the ECR plasma. We have adopted gas-mixing techniques in order to cool the plasma and then reduce fullerene dissociation. Mass spectra of ion beams extracted from fullerene-He, Ar or Xe mixed plasmas were observed with a Faraday cup. From the results, the He gas mixing technique is effective against fullerene destruction.
Collapse
|
12
|
Low energy Fe+ beam irradiation to C60 thin film. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012; 83:02A346. [PMID: 22380193 DOI: 10.1063/1.3675456] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
We have developed an electron cyclotron resonance ion source apparatus, which is designed for the production of endohedral fullerene. In this study, we irradiated the Fe(+) beam to the C(60) thin film. We changed the experimental condition of the dose and the ion energy. We could observe the Fe + C(60) peak by analysis of the time-of-flight mass spectrometry. The highest intensity of the Fe + C(60) peak was observed at the ion energy of 200 eV. The Fe + C(60) peak intensity tended to become high in the case of long irradiation time and large dose.
Collapse
|
13
|
Molecular and negative ion production by a standard electron cyclotron resonance ion source. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012; 83:02A313. [PMID: 22380160 DOI: 10.1063/1.3662960] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Molecular and negative ion beams, usually produced in special ion sources, play an increasingly important role in fundamental and applied atomic physics. The ATOMKI-ECRIS is a standard ECR ion source, designed to provide highly charged ion (HCI) plasmas and beams. In the present work, H(-), O(-), OH(-), O(2)(-), C(-), C(60)(-) negative ions and H(2)(+), H(3)(+), OH(+), H(2)O(+), H(3)O(+), O(2)(+) positive molecular ions were generated in this HCI-ECRIS. Without any major modification in the source and without any commonly applied tricks (such as usage of cesium or magnetic filter), negative ion beams of several μA and positive molecular ion beams in the mA range were successfully obtained.
Collapse
|
14
|
Effect of pulse-modulated microwaves on fullerene ion production with electron cyclotron resonance ion source. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012; 83:02A303. [PMID: 22380150 DOI: 10.1063/1.3656428] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Fullerene plasmas generated by pulse-modulated microwaves have been investigated under typical conditions at the Bio-Nano electron cyclotron resonance ion source. The effect of the pulse modulation is distinct from that of simply structured gases, and then the density of the fullerene plasmas increased as decreasing the duty ratio. The density for a pulse width of 10 μs at the period of 100 μs is 1.34 times higher than that for CW mode. We have studied the responses of fullerene and argon plasmas to pulsed microwaves. After the turnoff of microwave power, fullerene plasmas lasted ∼30 times longer than argon plasmas.
Collapse
|
15
|
Status and special features of the Atomki ECR ion source. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012; 83:02A341. [PMID: 22380188 DOI: 10.1063/1.3673006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
The ECR ion source has been operating in ATOMKI (Debrecen) since 1996. During the past 15 years lots of minor and numerous major technical modifications have been carried out on the ECRIS. Many of these changes aimed the increasing of beams charge, intensity, and the widening of the ion choice. Another group of the modifications were performed to develop special, non-standard operation modes or to produce peculiar plasmas and beams.
Collapse
|
16
|
Study on the beam transport from the Bio-Nano ECRIS. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012; 83:02B713. [PMID: 22380318 DOI: 10.1063/1.3670597] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
The beam transport of N(+) ion and C(60)(+) ion in the Bio-Nano ECRIS with min-B configuration was investigated based on the ion beam profiles. The N(+) beam could be focused under the low-beam current conditions. Also the C(60)(+) beam could be focused in spite of the large space-charge effect which will lead the divergence of the beam. We confirmed that our beam transport system works well even for the C(60)(+) ion beam. We estimated the highest C(60)(+) beam current with the focused beam profile by comparing the N(+) ion beam.
Collapse
|
17
|
Abstract
In this paper a study on the ion transmission ratio of a nanoporous alumina sample is presented. The sample was investigated by scanning transmission ion microscopy (STIM) with different beam sizes. The hexagonally close-packed Al(2)O(3) nanocapillary array, realized as a suspended membrane of 15 microm thickness, had pore diameters of approximately 215 nm and spacing of approximately 450 nm. When the proton beam size was limited to a single domain, a peak transmission ratio of 19% was observed as is expected from the geometry (approximately 19-20%). This result points out an almost perfectly parallel alignment of the capillaries within one domain. However, for larger beam scanning areas (sampling multiple domains) the transmission ratio was reduced to 5%. The STIM analysis over an area larger than the typical domain size revealed an overall capillary angular spread of approximately 2 degrees.
Collapse
|
18
|
Bio-Nano ECRIS: an electron cyclotron resonance ion source for new materials production. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2010; 81:02A306. [PMID: 20192327 DOI: 10.1063/1.3258027] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
We developed an electron cyclotron resonance ion source (ECRIS) for new materials production on nanoscale. Our main target is the endohedral fullerenes, which have potential in medical care, biotechnology, and nanotechnology. In particular, iron-encapsulated fullerene can be applied as a contrast material for magnetic resonance imaging or microwave heat therapy. Thus, our new ECRIS is named the Bio-Nano ECRIS. In this article, the recent progress of the development of the Bio-Nano ECRIS is reported: (i) iron ion beam production using induction heating oven and (ii) optimization of singly charged C(60) ion beam production.
Collapse
|
19
|
Review on heavy ion radiotherapy facilities and related ion sources (invited). THE REVIEW OF SCIENTIFIC INSTRUMENTS 2010; 81:02B909. [PMID: 20192475 DOI: 10.1063/1.3268510] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2009] [Accepted: 11/03/2009] [Indexed: 05/28/2023]
Abstract
Heavy ion radiotherapy awakens worldwide interest recently. The clinical results obtained by the Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences in Japan have clearly demonstrated the advantages of carbon ion radiotherapy. Presently, there are four facilities for heavy ion radiotherapy in operation, and several new facilities are under construction or being planned. The most common requests for ion sources are a long lifetime and good stability and reproducibility. Sufficient intensity has been achieved by electron cyclotron resonance ion sources at the present facilities.
Collapse
|
20
|
Electron cyclotron resonance plasma photos. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2010; 81:02B708. [PMID: 20192448 DOI: 10.1063/1.3267289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
In order to observe and study systematically the plasma of electron cyclotron resonance (ECR) ion sources (ECRIS) we made a high number of high-resolution visible light plasma photos and movies in the ATOMKI ECRIS Laboratory. This required building the ECR ion source into an open ECR plasma device, temporarily. An 8MP digital camera was used to record photos of plasmas made from Ne, Ar, and Kr gases and from their mixtures. We studied and recorded the effect of ion source setting parameters (gas pressure, gas composition, magnetic field, and microwave power) to the shape, color, and structure of the plasma. The analysis of the photo series gave us many qualitative and numerous valuable physical information on the nature of ECR plasmas.
Collapse
|
21
|
Multiply charged carbon-ion production for medical application. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2008; 79:02C303. [PMID: 18315243 DOI: 10.1063/1.2832361] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Over 3000 cancer patients have already been treated by the heavy-ion medical accelerator in Chiba at the National Institute of Radiological Sciences since 1994. The clinical results have clearly verified the effectiveness and safety of heavy-ion radiotherapy. The most important result has been to establish that the carbon ion is one of the most effective radiations for radiotherapy. The ion source is required to realize a stable beam with the same conditions for daily operation. However, the deposition of carbon ions on the wall of the plasma chamber is normally unavoidable. This causes an "anti-wall-coating effect," i.e., a decreasing of the beam, especially for the higher charge-state ions due to the surface material of the wall. The ion source must be required to produce a sufficiently intense beam under the bad condition. Other problems were solved by improvements and maintenance, and thus we obtained enough reproducibility and stability along with decreased failures. We summarize our over 13 years of experience, and show the scope for further developments.
Collapse
|
22
|
Application of compact electron cyclotron resonance ion source. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2008; 79:02A328. [PMID: 18315118 DOI: 10.1063/1.2816706] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
The compact electron cyclotron resonance (ECR) ion source with a permanent magnet configuration (Kei2 source) has been developed at National Institute of Radiological Sciences for a new carbon therapy facility. The Kei2 source was designed for production of C(4+) ions; its performance such as beam intensity and stability has already reached the medical requirements. Therefore, the prototype development of the source for medical use is essentially finished. Recently, we have started a few studies on other applications of the source. One is the production of fullerenes in the ECR plasma and modified fullerenes with various atoms for new materials. A second application is the production of multiply charged ions (not only carbon) for ion implantation. In this paper, some basic experiments for these applications are reported.
Collapse
|
23
|
Preliminary results of the ion extraction simulations applied to the MONO1000 and SUPERSHyPIE electron cyclotron resonance ion sources. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2008; 79:02B703. [PMID: 18315194 DOI: 10.1063/1.2814260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
The goal of this article is to present simulations on the extraction from an electron cyclotron resonance ion source (ECRIS). The aim of this work is to find out an extraction system, which allows one to reduce the emittances and to increase the current of the extracted ion beam at the focal point of the analyzing dipole. But first, we should locate the correct software which is able to reproduce the specific physics of an ion beam. To perform the simulations, the following softwares have been tested: SIMION 3D, AXCEL, CPO 3D, and especially, for the magnetic field calculation, MATHEMATICA coupled with the RADIA module. Emittance calculations have been done with two types of ECRIS: one with a hexapole and one without a hexapole, and the difference will be discussed.
Collapse
|
24
|
|