1
|
Kothala LP, Jonnala P, Guntur SR. Localization of mixed intracranial hemorrhages by using a ghost convolution-based YOLO network. Biomed Signal Process Control 2023. [DOI: 10.1016/j.bspc.2022.104378] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
2
|
Boppudi ST, Belal S, Guntur SR. Preparation and characterization of a novel sprayable hydrogel for skin preparation to record ECG and other biopotentials. Biomed Eng Lett 2020; 10:533-546. [PMID: 33194246 DOI: 10.1007/s13534-020-00164-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2020] [Revised: 06/30/2020] [Accepted: 07/20/2020] [Indexed: 10/23/2022] Open
Abstract
Wet electrodes are widely used to perform biopotential measurements from the body, such as electroencephalogram, electrocardiogram, and electromyogram. These electrodes have certain disadvantages, including bacterial growth, irritation in long-term recordings, infection to patients' skin caused by skin preparation techniques, and unpleasant feeling caused after their removal. Thus, a sprayable hydrogel (SH) was designed to avoid these problems. Five electrode configurations, namely, Zipprep™, wet Ag/AgCl, wipes, dry Ag/AgCl, and SH, were tested using an impedance analyzer. Measurements were obtained by placing each of the electrode systems on the forearm of five subjects, which comprised one Caucasian, two Indians, one Syrian, and one Cypriot aging between 23 and 60 years for 10 min. Impedance versus time and reactance versus resistance performance plots were compared and assessed. The performance of the SH sprayed under dry electrodes had lower impedance values compared with those of the dry Ag/AgCl and wipes. As a result, the SH electrode configuration can be used as an electrode set-up for acquiring and recording various physiological signals.
Collapse
Affiliation(s)
- Sunil Tej Boppudi
- Department of Biomedical Engineering, Vignan's Foundation for Science, Technology and Research, Vadlamudi, Guntur, 522213 India.,Department of Electronics and Communications Engineering, Vignan's Foundation for Science, Technology and Research, Vadlamudi, Guntur, 522213 India
| | - Suliman Belal
- School of Biological Sciences, Division of Neuroscience and Experimental Psychology, Manchester University, Zochonis Building, Brunswick Street, Manchester, M13 9PT UK
| | - Sitaramanjaneya Reddy Guntur
- Department of Biomedical Engineering, Vignan's Foundation for Science, Technology and Research, Vadlamudi, Guntur, 522213 India.,Department of Electronics and Communications Engineering, Vignan's Foundation for Science, Technology and Research, Vadlamudi, Guntur, 522213 India
| |
Collapse
|
3
|
Guntur SR, Choi MJ. Temperature Dependence of Tissue Thermal Parameters Should Be Considered in the Thermal Lesion Prediction in High-Intensity Focused Ultrasound Surgery. Ultrasound Med Biol 2020; 46:1001-1014. [PMID: 31983483 DOI: 10.1016/j.ultrasmedbio.2019.10.023] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2019] [Revised: 10/21/2019] [Accepted: 10/26/2019] [Indexed: 06/10/2023]
Abstract
This study considers the temperature-dependent thermal parameters (specific heat capacity, thermal diffusivity and thermal conductivity) used when predicting the temperature rise of tissue exposed to high-intensity focused ultrasound (HIFU). Numerical analysis was performed using the Khokhlov-Zabolotskaya-Kuznetsov equation coupled with a bioheat transfer function. The thermal parameters were set as the functions of temperature using experimental data. The results revealed that, for liver tissue exposed to HIFU with a focal intensity of 3000 W/cm2 for 10 s, the predicted focal temperature rise was 23% lower and the thermal lesion area 41% smaller than those predicted without considering the temperature dependence. The prediction was validated by experimental observations on thermal lesions visualized in a tissue-mimicking phantom. The present results suggest that temperature-dependent thermal parameters should be considered in the prediction of HIFU-induced temperature rise to avoid lowering ultrasonic output settings for HIFU surgery. The aim of the present study was to investigate how significantly the temperature dependence of the thermal parameters affects the thermal dose imposed on the tissue by a typical clinical HIFU device. A numerical simulation was performed using a thermo-acoustic algorithm coupling the non-linear Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation (Meaney et al. 1998; Filonenko and Khokhlova 2001) and a bio-heat transfer (BHT) equation (Pennes 1948). Thermal parameters of liver tissue were modeled in the present study as functions of temperature and were incorporated into the BHT equation to compensate for the variations in thermal parameters with temperature. Experimental validation was achieved by comparing the predictions with the thermal lesions formed in the tissue-mimicking phantoms.
Collapse
Affiliation(s)
- Sitaramanjaneya Reddy Guntur
- Department of Biomedical Engineering, Vignan's Foundation for Science, Technology and Research, Vadlamudi, Guntur, India
| | - Min Joo Choi
- Department of Medicine, School of Medicine, Jeju National University, Jeju, Republic of Korea.
| |
Collapse
|
4
|
Guntur SR, Kumar NS, Hegde MM, Dirisala VR. In Vitro Studies of the Antimicrobial and Free-Radical Scavenging Potentials of Silver Nanoparticles Biosynthesized From the Extract of Desmostachya bipinnata. Anal Chem Insights 2018; 13:1177390118782877. [PMID: 30013309 PMCID: PMC6039906 DOI: 10.1177/1177390118782877] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2017] [Accepted: 05/03/2018] [Indexed: 12/12/2022]
Abstract
The aim of this study was to perform green synthesis of silver nanoparticles (AgNPs) from the leaf extract of Desmostachya bipinnata (Dharba), a medicinally important herb which is widely used across India. Synthesized AgNPs were analyzed by UV-Visible spectroscopy, X-ray diffraction (XRD), Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDAX). The results have confirmed that green synthesis of AgNPs leads to the fabrication of sphere-shaped particles with a diameter of 53 nm. Furthermore, these AgNPs were subjected to antioxidant and antimicrobial studies against gram-negative and gram-positive bacteria, where AgNPs at a concentration of 20 mg/mL showed highest zone of inhibition. Synthesized AgNPs were evaluated for their antioxidant activity by 1, 1-diphenyl-2-picryl hydrazyl radical (DPPH), H2O2, and superoxide inhibiting assays; increasing concentration has showed increase in scavenging ability. Cell toxicity was assessed on HepG2 cell lines, and synthesized nanoparticles at a concentration of 128 μg/mL produced significant reduction in viability of Hep cells (P < .05). The availability of Dharba throughout the year and the eco-friendly approach in the synthesis of AgNPs coupled with bioactivity has demonstrated its potential as a novel biomaterial which can be used for various biomedical applications.
Collapse
Affiliation(s)
- Sitaramanjaneya Reddy Guntur
- Department of Biomedical Engineering, Vignan's Foundation for Science, Technology & Research (Deemed to be University), Guntur, India
| | - Ns Sampath Kumar
- Department of Biotechnology, Vignan's Foundation for Science, Technology & Research (Deemed to be University), Guntur, India
| | - Manasa M Hegde
- Department of Nanotechnology, Rajiv Gandhi Institute of Technology, Bangalore, India
| | - Vijaya R Dirisala
- Department of Biotechnology, Vignan's Foundation for Science, Technology & Research (Deemed to be University), Guntur, India
| |
Collapse
|
5
|
Guntur SR, Choi MJ. Influence of temperature-dependent thermal parameters on temperature elevation of tissue exposed to high-intensity focused ultrasound: numerical simulation. Ultrasound Med Biol 2015; 41:806-813. [PMID: 25638316 DOI: 10.1016/j.ultrasmedbio.2014.10.008] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/16/2014] [Revised: 10/17/2014] [Accepted: 10/20/2014] [Indexed: 06/04/2023]
Abstract
High-intensity focused ultrasound (HIFU) has been used successfully as a non-invasive modality in treating solid tumors. The temperature rise HIFU irradiation causes in a tissue depends on the thermal properties of the tissue. This study was motivated by our observation that the thermal properties of a tissue vary significantly with temperature (Guntur SR, Lee KI, Paeng DG, Coleman AJ, Choi MJ. Ultrasound Med Biol 2013;39:1771-1784). This research investigated how significantly the alteration of tissue thermal parameters, in the ranges of values measured at 25°C-90°C, affects prediction of the temperature elevation of tissue under the same HIFU exposure. The numerical simulation was performed by coupling a non-linear Khokhlov-Zabolotskaya-Kuznetsov equation with a bio-heat transfer function. In the conventional method of prediction, the thermal parameters were set as constants measured at room temperature (25°C). This study compared the conventional prediction with those predicted with different thermal parameters measured at the various temperatures up to 90°C. The results indicated that the conventional method significantly overestimated the rise in focal temperature in the liver tissue exposed to a clinical HIFU field, compared with the prediction made using thermal parameters measured at temperatures that cause thermal denaturation. This finding suggests that temperature-dependent thermal parameters should be considered in predicting the temperature rise in a tissue to avoid use of an insufficient thermal dose in treatment planning for HIFU surgery.
Collapse
Affiliation(s)
- Sitaramanjaneya Reddy Guntur
- Interdisciplinary Postgraduate Program of Biomedical Engineering, Jeju National University, Jeju, Republic of Korea
| | - Min Joo Choi
- Interdisciplinary Postgraduate Program of Biomedical Engineering, Jeju National University, Jeju, Republic of Korea; Department of Medicine, School of Medicine, Jeju National University, Jeju, Republic of Korea.
| |
Collapse
|
6
|
Guntur SR, Choi MJ. An improved tissue-mimicking polyacrylamide hydrogel phantom for visualizing thermal lesions with high-intensity focused ultrasound. Ultrasound Med Biol 2014; 40:2680-2691. [PMID: 25220272 DOI: 10.1016/j.ultrasmedbio.2014.06.010] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2013] [Revised: 06/03/2014] [Accepted: 06/17/2014] [Indexed: 06/03/2023]
Abstract
A recipe was created to improve the tissue-mimicking (TM) bovine serum albumin (BSA) polyacrylamide hydrogel (PAG) reported in our previous study (Choi MJ, Guntur SR, Lee KI, Paeng DG, Coleman AJ. Ultrasound Med Biol 2013; 29:439-448). In that work, the concentration of acrylamide in TM BSA PAG was increased to make its attenuation coefficient the same as that of a tissue. However, this increase made the PAG stiffer and less homogeneous. In addition, the increase in acrylamide caused a significant increase in temperature over the denaturation threshold of BSA during polymerization, which required forced cooling so that the PAG did not become opaque at room temperature after polymerization. To eliminate those shortcomings, we substituted the increased acrylamide with a viscous polysaccharide liquid (corn syrup). The concentration of corn syrup was optimized to 20% (w/v, tested in the volume of 50 mL), so that the acoustic properties of the PAG would be close to those of human liver. The improved TM (iTM) BSA PAG constructed in this study had a speed of sound of 1588 ± 9 m/s, an attenuation coefficient of 0.51 ± 0.06 dB cm(-1) at 1 MHz and a backscattering coefficient of 0.22 ± 0.09 × 10(-3) sr(-1) cm(-1) MHz(-1). The density and acoustic impedance were 1057 kg/m(3) and 1.68 MRayl, respectively, and the non-linear parameter (B/A) was 5.9 ± 0.3. The thermal, optical and mechanical properties were almost the same as those of the BSA PAG (Lafon et al.2005). Experimental verification indicated that the thermal lesions visualized in the proposed iTM BSA PAG by high-intensity focused ultrasound were highly reproducible. In conclusion, iTM BSA PAG was proven to eliminate TM BSA PAG shortcomings effectively and is expected to be a promising test phantom for clinical high-intensity focused ultrasound device.
Collapse
Affiliation(s)
- Sitaramanjaneya Reddy Guntur
- Interdisciplinary Postgraduate Program of Biomedical Engineering, Jeju National University, Jeju, Republic of Korea; Rajiv Gandhi Institute of Technology, Visvesvaraya Technological University, Bangalore, India
| | - Min Joo Choi
- Interdisciplinary Postgraduate Program of Biomedical Engineering, Jeju National University, Jeju, Republic of Korea; Department of Medicine, School of Medicine, Jeju National University, Jeju, Republic of Korea.
| |
Collapse
|
7
|
Guntur SR, Lee KI, Paeng DG, Coleman AJ, Choi MJ. Temperature-dependent thermal properties of ex vivo liver undergoing thermal ablation. Ultrasound Med Biol 2013; 39:1771-84. [PMID: 23932271 DOI: 10.1016/j.ultrasmedbio.2013.04.014] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2012] [Revised: 04/17/2013] [Accepted: 04/18/2013] [Indexed: 05/08/2023]
Abstract
Thermotherapy uses a heat source that raises temperatures in the target tissue, and the temperature rise depends on the thermal properties of the tissue. Little is known about the temperature-dependent thermal properties of tissue, which prevents us from accurately predicting the temperature distribution of the target tissue undergoing thermotherapy. The present study reports the key thermal parameters (specific heat capacity, thermal conductivity and heat diffusivity) measured in ex vivo porcine liver while being heated from 20 ° C to 90 ° C and then naturally cooled down to 20 ° C. The study indicates that as the tissue was heated, all the thermal parameters resulted in plots with asymmetric quasi-parabolic curves with temperature, being convex downward with their minima at the turning temperature of 35-40 ° C. The largest change was observed for thermal conductivity, which decreased by 9.6% from its initial value (at 20 ° C) at the turning temperature (35 ° C) and rose by 45% at 90 ° C from its minimum (at 35 ° C). The minima were 3.567 mJ/(m(3) ∙ K) for specific heat capacity, 0.520 W/(m.K) for thermal conductivity and 0.141 mm(2)/s for thermal diffusivity. The minimum at the turning temperature was unique, and it is suggested that it be taken as a characteristic value of the thermal parameter of the tissue. On the other hand, the thermal parameters were insensitive to temperature and remained almost unchanged when the tissue cooled down, indicating that their variations with temperature were irreversible. The rate of the irreversible rise at 35 ° C was 18% in specific heat capacity, 40% in thermal conductivity and 38.3% in thermal diffusivity. The study indicates that the key thermal parameters of ex vivo porcine liver vary largely with temperature when heated, as described by asymmetric quasi-parabolic curves of the thermal parameters with temperature, and therefore, substantial influence on the temperature distribution of the tissue undergoing thermotherapy is expected.
Collapse
Affiliation(s)
- Sitaramanjaneya Reddy Guntur
- Interdisciplinary Postgraduate Program of Biomedical Engineering, Jeju National University, Jeju Special Self-Governing Province, Jeju-Si, Republic of Korea
| | | | | | | | | |
Collapse
|
8
|
Choi MJ, Guntur SR, Lee KI, Paeng DG, Coleman A. A tissue mimicking polyacrylamide hydrogel phantom for visualizing thermal lesions generated by high intensity focused ultrasound. Ultrasound Med Biol 2013; 39:439-448. [PMID: 23312531 DOI: 10.1016/j.ultrasmedbio.2012.10.002] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2012] [Revised: 09/03/2012] [Accepted: 10/02/2012] [Indexed: 06/01/2023]
Abstract
An optically transparent tissue-mimicking (TM) phantom whose acoustic properties are close to those of tissue was constructed for visualizing therapeutic effects by high intensity focused ultrasound (HIFU). The TM phantom was designed to improve a widely used standard bovine serum albumin (BSA) polyacrylamide hydrogel (PAG), which attenuated ultrasound far less than tissue and, unlike tissue, did not scatter ultrasound. A modified recipe has been proposed in the study by adding scattering glass beads with diameters of 40-80 μm (0.002% w/v) and by raising the concentration of acrylamide (30% v/v). The TM BSA-PAG constructed has an acoustic impedance of 1.67 MRayls, a speed of sound of 1576 m/s, an attenuation coefficient of 0.52 dB/cm at 1 MHz, a backscattering coefficient of 0.242 × 10(-3) 1/sr/cm at 1 MHz and a nonlinear parameter (B/A) of 5.7. These parameters are close to those of liver. The thermal and optical properties are almost the same as the standard BSA-PAG. The characteristic features of the thermal lesions by HIFU were observed to be more accurately visualized in the TM BSA-PAG than in the standard BSA-PAG. In conclusion, the proposed TM BSA-PAG acoustically mimics tissue better than the standard BSA-PAG and is expected to be preferentially used for assuring if a clinical HIFU device produces the thermal lesion as planned.
Collapse
Affiliation(s)
- Min Joo Choi
- Interdisciplinary Postgraduate Program of Biomedical Engineering, Jeju National University, Jeju, Republic of Korea.
| | | | | | | | | |
Collapse
|
9
|
Choi MJ, Guntur SR, Lee JM, Paeng DG, Lee KIL, Coleman A. Changes in ultrasonic properties of liver tissue in vitro during heating-cooling cycle concomitant with thermal coagulation. Ultrasound Med Biol 2011; 37:2000-12. [PMID: 22107907 DOI: 10.1016/j.ultrasmedbio.2011.06.015] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2011] [Revised: 06/13/2011] [Accepted: 06/23/2011] [Indexed: 05/16/2023]
Abstract
The present work considers the ultrasonic properties of porcine liver tissue in vitro measured during heating concomitant with thermal coagulation followed by natural cooling, so as to provide information about changes in the ultrasonic properties of the tissue after thermal coagulation. The excised liver samples were heated in a degassed water bath up to 75°C and naturally cooled down to 30°C. The tissue was observed to begin thermally coagulating at temperatures lower than 75°C. The ultrasonic parameters considered include the speed of sound, the attenuation coefficient, the backscatter coefficient and the nonlinear parameter of B/A. They were more sensitive to temperature when heating than during natural cooling. All of the parameters were shown to rise significantly on completion of the heating-cooling cycle. At 35°C after thermal coagulation, the B/A value was increased by 96%, the attenuation and backscatter coefficients were increased by 50%∼68% and 33%∼37%, respectively, in the typical frequency ranges of 3 MHz∼5 MHz used for ultrasonic imaging and the speed of sound was increased by 1.4%. The results of this study added to the evidence that tissue characterization, in particular, based on the B/A could be valuable for ultrasonically imaging the thermal lesions following high-intensity focused ultrasound (HIFU) surgery.
Collapse
Affiliation(s)
- Min Joo Choi
- Interdisciplinary Postgraduate Program of Biomedical Engineering, Jeju National University, Jeju, Republic of Korea.
| | | | | | | | | | | |
Collapse
|