1
|
Abstract
UNLABELLED The CFP stem represents a short collared neck-retaining stem with very proximal metaphyseal anchoring along the calcar combined with up-to-date metallurgy. Despite theoretical advantages, the stability and clinical outcome are unknown. We prospectively measured the migration pattern of this new stem and cup. Twenty-six patients (26 hips) with a mean age of 54 years (range, 40-66 years) underwent THA and were followed for 2 years with radiostereometry, radiographs, and clinical scores. The stem showed some early retroversion (mean, SEM 0.6 degrees, 0.3), but stabilized before 1 year. Subsidence (0.05 mm, 0.06) and varus-valgus tilting (0.03 degrees, 0.01) were low. We observed no bone loss in the calcar region. Factors related to patients, implant design, and implantation did not predict migration patterns. The two-dimensional wear of the ceramic/conventional articulation was 0.09 mm at 2-24 months. The low migration of this short neck preserving stem suggests a favorable long-term outcome but longer followup is needed to substantiate this prediction. This design might become an alternative to standard stems and hip resurfacing. LEVEL OF EVIDENCE Therapeutic Level IV. See The Guidelines for Authors for a complete description of levels of evidence.
Collapse
|
Comparative Study |
19 |
65 |
2
|
Tsukanaka M, Halvorsen V, Nordsletten L, EngesæTer IØ, EngesæTer LB, Marie Fenstad A, Röhrl SM. Implant survival and radiographic outcome of total hip replacement in patients less than 20 years old. Acta Orthop 2016; 87:479-84. [PMID: 27435903 PMCID: PMC5016906 DOI: 10.1080/17453674.2016.1212180] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Total hip replacement (THR) is not recommended for children and very young teenagers because early and repetitive revisions are likely. We investigated the clinical and radiographic outcomes of THR performed in children and teenage patients. Patients and methods - We included 111 patients (132 hips) who underwent THR before 20 years of age. They were identified in the Norwegian Arthroplasty Register, together with information on the primary diagnosis, types of implants, and any revisions that required implant change. Radiographs and Harris hip score (HHS) were also evaluated. Results - The mean age at primary THR was 17 (11-19) years and the mean follow-up time was 14 (3-26) years. The 10-year survival rate after primary THR (with the endpoint being any revision) was 70%. 39 patients had at least 1 revision and 16 patients had 2 or more revisions. In the latest radiographs, osteolysis and atrophy were observed in 19% and 27% of the acetabulae and 21% and 62% of the femurs, respectively. The mean HHS at the final follow-up was 83 (15-100). Interpretation - The clinical score after THR in these young patients was acceptable, but many revisions had been performed. However, young patients with developmental dysplasia of the hip had lower implant survival. Moreover, the bone stock in these patients was poor, which could complicate future revisions.
Collapse
|
research-article |
9 |
61 |
3
|
Aunan E, Kibsgård TJ, Diep LM, Röhrl SM. Intraoperative ligament laxity influences functional outcome 1 year after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2015; 23:1684-92. [PMID: 24917538 PMCID: PMC4439434 DOI: 10.1007/s00167-014-3108-0] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/09/2013] [Accepted: 05/29/2014] [Indexed: 12/04/2022]
Abstract
PURPOSE To find out if there is an association between ligament laxity measured intraoperatively and functional outcome 1 year after total knee arthroplasty (TKA). METHODS Medial and lateral ligament laxities were measured intraoperatively in extension and in 90° of flexion in 108 patients [122 knees; median age 70 (range 42-83) years]. Mechanical axes were measured preoperatively and at 1-year follow-up. Outcome measures were the Knee Injury and Osteoarthritis Outcome Score (KOOS), the Knee Society Clinical Rating System, the Oxford Knee Score and patient satisfaction. The relationships between laxity and outcome scores were examined by median regression analyses. RESULTS Post-operative mechanical axis had a significant effect on the association between ligament laxity and KOOS. Therefore, the material was stratified on post-operative mechanical axis. In perfectly aligned and valgus-aligned TKAs, there was a negative correlation between medial laxity and all subscores in KOOS. The most important regression coefficient (β) was recorded for the effect of medial laxity in extension on activities of daily living (ADLs) (β = -7.32, p < 0.001), sport/recreation (β = -6.9, p = 0.017) and pain (β = -5.9, p = 0.006), and for the effect of medial laxity in flexion on ADLs (β = -3.11, p = 0.023) and sport/recreation (β = -4.18, p = 0.042). CONCLUSIONS In order to improve the functional results after TKA, orthopaedic surgeons should monitor ligament laxity and mechanical axis intraoperatively and avoid medial laxity more than 2 mm in extension and 3 mm in flexion in neutral and valgus-aligned knees. LEVEL OF EVIDENCE II.
Collapse
|
research-article |
10 |
59 |
4
|
Börlin N, Röhrl SM, Bragdon CR. RSA wear measurements with or without markers in total hip arthroplasty. J Biomech 2005; 39:1641-50. [PMID: 15990104 DOI: 10.1016/j.jbiomech.2005.05.004] [Citation(s) in RCA: 57] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2004] [Accepted: 05/01/2005] [Indexed: 11/17/2022]
Abstract
Novel algorithms for radiostereometric (RSA) measurements of the femoral head and metal-backed, hemi-spherical cups of a total hip replacement are presented and evaluated on phantom images and clinical double examinations of 20 patients. The materials were analysed with classical RSA and three novel algorithms: (1) a dual-projection head algorithm using the outline of the femoral head together with markers in the cup; (2) a marker-less algorithm based on measurements of the outline of the femoral head, the cup shell and opening circle of the cup; and (3) a combination of both methods. The novel algorithms improve current, marker-based, RSA measurements, as well as allows studies without marked cups. This opens the possibility of performing wear measurements on larger group of patients, in clinical follow-ups, even retrospective studies. The novel algorithms may help to save patient data in current RSA studies lost due to insufficiently marked cups. Finally, the novel algorithms simplify the RSA procedure and allow new studies without markers, saving time, money, and reducing safety concerns. Other potential uses include migration measurements of re-surfacing heads and measuring spherical sections as implant landmarks instead of markers.
Collapse
|
Journal Article |
20 |
57 |
5
|
Röhrl S, Nivbrant B, Mingguo L, Hewitt B. In vivo wear and migration of highly cross-linked polyethylene cups a radiostereometry analysis study. J Arthroplasty 2005; 20:409-13. [PMID: 16124954 DOI: 10.1016/j.arth.2004.09.040] [Citation(s) in RCA: 56] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2003] [Accepted: 02/08/2004] [Indexed: 02/01/2023] Open
Abstract
In 50 cemented hip arthroplasties, wear and migration of the polyethylene (PE) cups were measured with radiostereometric analysis for a period of 2 years. Twenty had a normal gamma-in-air-sterilized PE, another 20 had a PE sterilized with 30000 Gy followed by heat stabilization (Duration; Stryker Orthopaedics, Mahwah, NJ), and 10 had highly cross-linked PE cups irradiated with 100000 Gy (Crossfire; Stryker Orthopaedics). In the initial 2 months, head penetration (creep) was 63 microm on average for the 3 groups. From 2 to 24 months, the mean proximal head penetration (wear) was 156 microm for standard PE, 138 microm for stabilized PE (P = .45), and 23 microm for highly cross-linked PE (P < .001; analysis of variance). The low in vivo wear rate for highly cross-linked cups was not at the expense of higher migration or less favorable clinical outcome and looks promising.
Collapse
|
|
20 |
56 |
6
|
Petursson G, Fenstad AM, Gøthesen Ø, Dyrhovden GS, Hallan G, Röhrl SM, Aamodt A, Furnes O. Computer-Assisted Compared with Conventional Total Knee Replacement: A Multicenter Parallel-Group Randomized Controlled Trial. J Bone Joint Surg Am 2018; 100:1265-1274. [PMID: 30063588 DOI: 10.2106/jbjs.17.01338] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND We previously reported the short-term radiographic and functional results of a randomized controlled trial (RCT) comparing computer-assisted and conventionally performed total knee replacement. We currently report the 2-year clinical results from this trial. METHODS One hundred and ninety patients were randomly allocated to undergo either computer-assisted or conventional total knee replacement. One hundred and seventy-two patients were available for clinical evaluation at 2 years, and 167 (97%) of those answered all patient-reported outcome measures (PROMs), including the Knee Injury and Osteoarthritis Outcome Score (KOOS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Knee Society Score (KSS), visual analog scale (VAS), and EuroQol-5 Dimensions (EQ-5D). Patients and clinical evaluators were blinded to the method of surgery. Surgical outcome was assessed using the Outcome Measures in Rheumatology-Osteoarthritis Research Society International (OMERACT-OARSI) criteria to calculate responder rates, divided into high responders, moderate responders, and nonresponders. RESULTS The computer-assisted group had significantly more improvement than the conventional group in the mean scores for 2 subscales of the KOOS (7.4 for symptoms [p = 0.02] and 16.2 for sport and recreation [p < 0.01]) and in 1 subscale of the WOMAC (8.8 for stiffness [p = 0.03]).The computer-assisted group also had significantly more high responders (82.8%) than the conventional group (68.8%; p = 0.03) at 2 years, with the number needed to treat determined to be 8. CONCLUSIONS In this study, the use of computer navigation provided better pain relief and restored better function than the use of the conventional surgical technique at 2 years after total knee replacement. LEVEL OF EVIDENCE Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
Comparative Study |
7 |
52 |
7
|
Röhrl SM, Li MG, Nilsson KG, Nivbrant B. Very low wear of non-remelted highly cross-linked polyethylene cups: an RSA study lasting up to 6 years. Acta Orthop 2007; 78:739-45. [PMID: 18236179 DOI: 10.1080/17453670710014509] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND AND PURPOSE Highly cross-linked polyethylenes (PEs) all appear to reduce wear dramatically in laboratory studies, although there is substantial variation in this respect between manufacturers. Nonremelted cross-linked PE is almost as tough as unirradiated PE, but is not completely stable and can oxidize in vivo, as has been shown in recent retrievals studies. We had reported low wear and good clinical performance after 2 years for 10 non-remelted highly crosslinked PE cups compared to 16 conventional PE cups sterilized by gamma-in-air. METHOD Because of possible degradation by free radicals, we followed up both cohorts for 5 years (conventional PE) and 6 years (highly cross-linked PE). RESULT Mean (CI) proximal head penetration over the observation time was linear and measured 0.08 (0.02-0.13) mm for cross-linked PE and 0.42 (0.23-0.62) mm for conventional PE, and total penetration was 0.23 (0.1-0.35) mm and 0.75 (0.05-1.4) mm respectively. After subtracting creep, the annual wear for non-remelted highly cross-linked PE was below 6 microm. The cups had equally low migration and few radiolucencies. INTERPRETATION The theoretical possibility of oxidation in non-remelted highly cross-linked PE may not show clinically. However, it may be that cemented cups with their thicker PE are more forgiving than metal-backed cups with thin PE moving in the locking mechanism. So far, we can conclude that the Crossfire highly crosslinked polyethylene cups performed very well clinically, with extremely low wear even after almost 6 years. This is reassuring, but care should be taken in extrapolating these results to other cross-linked PEs or uncemented cups where toughness of PE is more of an issue.
Collapse
|
|
18 |
49 |
8
|
Digas G, Thanner J, Nivbrant B, Röhrl S, Ström H, Kärrholm J. Increase in early polyethylene wear after sterilization with ethylene oxideRadiostereometric analyses of 201 total hips. ACTA ACUST UNITED AC 2009; 74:531-41. [PMID: 14620972 DOI: 10.1080/00016470310017910] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
We evaluated polyethylene wear by measuring femoral head penetration in 201 THA (median age 62 (31-81) years, 117 women) extracted from 5 randomized studies aimed to assess various fixation principles. There were 30 cemented all-polyethylene Lubinus cups sterilized by gamma irradiation in a reduced oxygen environment, 65 porous-coated Trilogy cups with liners gamma-sterilized in inert gas. Moreover, 37 cemented cups were sterilized with ethylene oxide (Reflection all-poly) and 69 porous-coated cups had liners sterilized in ethylene oxide (Reflection). 28 mm femoral heads were used in all cups. The patients were followed with repeated radiostereometric measurements (RSA) up to 2 years. The activity level of the patients was evaluated by a questionnaire. After 2 years, cups with polyethylene sterilized in EtO had almost twice the proximal and 3D penetration rates, as compared with gamma-sterilized polyethylene. The penetration did not differ between the gamma-irradiated designs. Using stepwise linear regression analysis, we found that the type of sterilization, age and weight were the most important predictors and that they determined the direction of the proximal penetration rate. Activity score, male gender and proximal migration of the cup had little effect. The accelerated wear observed with the EtO-sterilized polyethylene causes concerns about long-term problems and especially in younger patients.
Collapse
|
|
16 |
43 |
9
|
Bøe BG, Röhrl SM, Heier T, Snorrason F, Nordsletten L. A prospective randomized study comparing electrochemically deposited hydroxyapatite and plasma-sprayed hydroxyapatite on titanium stems. Acta Orthop 2011; 82:13-9. [PMID: 21189109 PMCID: PMC3229992 DOI: 10.3109/17453674.2010.548027] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Plasma-sprayed hydroxyapatite (HA) is a successful coating for fixation of uncemented femoral stems. There may be alternative coatings with advantages in bone remodeling and transport of bone-active substances. We investigated whether an electrochemically deposited hydroxyapatite, Bonemaster (BM), might be a safe alternative in total hip arthroplasty. Our hypothesis was that the new coating would not be inferior to the conventional one. PATIENTS AND METHODS 50 patients (55 hips) were included. The stem was tapered and porous-coated proximally. On top of the porous coating was either HA or BM. Patients were evaluated postoperatively and after 3, 6, 12, and 24 months to measure fixation by radiostereometric analysis (RSA), bone mineral density by dual-energy X-ray absorptiometry (DXA), and conventional radiography. Clinical evaluation was performed with Harris hip score and Oxford hip score, both preoperatively and after 2 years. RESULTS After 2 years, the stems had subsided 0.25 (HA) and 0.28 (BM) mm and there were no statistically significant differences between the groups in any direction, regarding both migration and rotation. The BM group retained significantly more bone than the HA group in Gruen zone 1 during the first 2 years. The Harris and Oxford hip scores were similar in both groups. INTERPRETATION Electrochemically deposited hydroxyapatite on an uncemented stem does not appear to be inferior to plasma-sprayed HA regarding clinical and radiological results, bone remodeling, and micromotion after 2 years follow-up.
Collapse
|
research-article |
14 |
36 |
10
|
Röhrl SM, Nivbrant B, Nilsson KG. No adverse effects of submelt-annealed highly crosslinked polyethylene in cemented cups: an RSA study of 8 patients 10 yaers after surgery. Acta Orthop 2012; 83:148-52. [PMID: 22248172 PMCID: PMC3339528 DOI: 10.3109/17453674.2011.652889] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Highly crosslinked polyethylene (PE) is in standard use worldwide. Differences in the crosslinking procedure may affect the clinical performance. Experimenatal data from retrieved cups have shown free radicals and excessive wear of annealed highly crosslinked PE. We have previously reported low wear and good clinical performance after 6 years with this implant, and now report on the 10-year results. PATIENTS AND METHODS In 8 patients, we measured wear of annealed highly crosslinked PE prospectively with radiostereometry after 10 years. Activity was assessed by UCLA activity score and a specifically designed activity score. Conventional radiographs were evaluated for osteolysis and clinical outcome by the Harris hip score (HHS). RESULTS The mean (95% CI) proximal head penetration for highly crosslinked PE after 10 years was 0.07 (-0.015 to 0.153) mm, and the 3D wear was 0.2 (0.026 to 0.36) mm. Without creep, proximal head penetration was 0.02 (-0.026 to 0.066) mm and for 3D penetration was 0.016 (-0.47 to 0.08) mm. This represents an annual proximal wear of less than 2 µm. All cups were clinically and radiographically stable but showed a tendency of increased rotation after 5 years. INTERPRETATION Wear for annealed highly crosslinked PE is extremely low up to 10 years. Free radicals do not affect mechanical performance or lead to clinically adverse effects. Creep stops after the first 6 months after implantation. Highly crosslinked PE is a true competitor of hard-on-hard bearings.
Collapse
|
research-article |
13 |
35 |
11
|
Röhrl SM, Nivbrant B, Snorrason F, Kärrholm J, Nilsson KG. Porous-coated cups fixed with screws: a 12-year clinical and radiostereometric follow-up study of 50 hips. Acta Orthop 2006; 77:393-401. [PMID: 16819677 DOI: 10.1080/17453670610046316] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Excellent mid-term results have stimulated the use of hemispherical porous-coated cups in hip replacement. With longer follow-up, there have been problems related to polyethylene wear and liner fixation, and osteolysis has been documented in reports of selected cases. We evaluated the clinical and radiographic results of 50 patients followed for 12 years. PATIENTS AND METHODS 58 consecutive patients (58 hips), mean age 55 years, were operated with Harris-Galante (HG) I or II cups using line-to-line fit and additional screw fixation. Polyethylene linersgamma-sterilized in air and 32-mm ceramic heads were used. 8 patients died within 12 years, leaving 50 patients with a complete 12 year follow-up. 23 of the cups were also evaluated with radiostereometry (RSA) for migration, liner stability, and wear. RESULTS All metal shells were still in situ after 12 years. 4 hips had been revised due to femoral loosening. In these revisions, the liner had been exchanged due to wear and/or instability, resulting in a cup survival rate of 89%. 28 cups displayed osteolytic lesions, mainly in relation to screws. RSA revealed minimum translations, but in many cases there were pronounced liner rotations suggesting unstable liners within the metal shell. The annual proximal wear was 0.09 mm and the three-dimensional wear was 0.16 mm. INTERPRETATION RSA can predict the long-term performance of cup fixation. Low migration during the initial years after implantation indicates excellent long-term results regarding fixation of the metal shell. The main problem with this design appears to be liner instability and osteolysis, factors that are probably interrelated. Because these phenomena are clinically silent, we recommend regular follow-up of patients with HG cups to avoid sudden loosening and complicated revisions.
Collapse
|
|
19 |
34 |
12
|
Aunan E, Kibsgård T, Clarke-Jenssen J, Röhrl SM. A new method to measure ligament balancing in total knee arthroplasty: laxity measurements in 100 knees. Arch Orthop Trauma Surg 2012; 132:1173-81. [PMID: 22581351 PMCID: PMC3400753 DOI: 10.1007/s00402-012-1536-1] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/05/2012] [Indexed: 12/03/2022]
Abstract
BACKGROUND Ligament balancing is considered a prerequisite for good function and survival in total knee arthroplasty (TKA). However, there is no consensus on how to measure ligament balance intra-operatively and the degree of stability obtained after different balancing techniques is not clarified. PURPOSE This study presents a new method to measure ligament balancing in TKA and reports on the results of a try-out of this method and its inter-observer reliability. METHODS After the implantation of the prosthesis, spatulas of different thickness were used to measure medial and lateral condylar lift-off in flexion and extension in 70 ligament-balanced knees and in 30 knees were ligament balancing was considered unnecessary. Inter-observer reliability for the new method was estimated and the degree of medial-lateral symmetry in extension and in flexion, and the equality of the extension gaps and flexion gaps were calculated. RESULTS The method was feasible in all operated knees, and found to be very reliable (intraclass correlation coefficient = 0.88). We found no statistically significant difference in condylar lift-off between the ligament-balanced and the non ligament-balanced group, however, there was a tendency to more outliers in flexion in the ligament-balanced group. CONCLUSIONS Our method for measuring ligament balance is reliable and provides valuable information in assessing laxity intra-operatively. This method may be a useful tool in further research on the relationship between ligament balance, function and survival of TKA.
Collapse
|
research-article |
13 |
33 |
13
|
Röhrl SM, Nivbrant B, Ström H, Nilsson KG. Effect of augmented cup fixation on stability, wear, and osteolysis: a 5-year follow-up of total hip arthroplasty with RSA. J Arthroplasty 2004; 19:962-71. [PMID: 15586331 DOI: 10.1016/j.arth.2004.06.024] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
To evaluate different modes of cementless fixation of hemispherical cups, we operated on 87 hips in 81 patients using 4 different means of cup fixation. The hips were randomly assigned to fixation with press-fit technique only (PF), or with augmentation with screws (S), pegs (P), or hydroxyapatite (HA) coating. The patients were evaluated with radiostereometric analysis (RSA) for cup migration and wear, conventional radiography for osteolysis, and Harris Hip Score for clinical outcome over 5 years. The fixation of the cups did not differ between the groups, but HA showed a tendency to decrease proximal migration. HA-coated cups displayed the best interface with hardly any signs of radiolucent lines, indicating a superior sealing effect of the HA coating. Cups with screws or pegs had more radiolucent lines and osteolytic lesions than the other groups. Radiolucent lines were correlated to higher proximal migration, young age, and female gender (r2=.2). The wear rate of the ethylene oxide-sterilized polyethylene liner was high (0.2 mm/y) but did not differ between the groups. Two cups with a perioperative fracture of the acetabular rim showed large initial migration but stabilized thereafter.
Collapse
|
Clinical Trial |
21 |
32 |
14
|
Halvorsen V, Fenstad AM, Engesæter LB, Nordsletten L, Overgaard S, Pedersen AB, Kärrholm J, Mohaddes M, Eskelinen A, Mäkelä KT, Röhrl SM. Outcome of 881 total hip arthroplasties in 747 patients 21 years or younger: data from the Nordic Arthroplasty Register Association (NARA) 1995-2016. Acta Orthop 2019; 90:331-337. [PMID: 31088343 PMCID: PMC6718182 DOI: 10.1080/17453674.2019.1615263] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - The literature is scarce on the outcome of the youngest patients with total hip arthroplasties (THAs). We analyzed register data, revision risk, and related factors in patients 21 years or younger with THAs in the Nordic Arthroplasty Register Association (NARA). Patients and methods - We included all THA patients 21 years or younger reported during 1995 through 2016 to the Danish, Finnish, Norwegian, and Swedish hip arthroplasty registers and merged these into the NARA dataset. Primary outcome was any implant revision. Results - We identified 881 THAs in 747 patients. Mean age at primary surgery was 18 years (9-21). The indications for THA were pediatric hip diseases (33%), systemic inflammatory disease (23%), osteoarthritis (4%), avascular necrosis (12%), hip fracture sequelae (7%), and other diagnoses (21%). Unadjusted 10-year survival for all THAs was 86%. Comparison between indications showed no differences in survival. Uncemented implants were used most frequently. Survival for uncemented and cemented implants was the same adjusted for sex, indication, head size, and time period for primary surgery. Aseptic loosening was the main cause of revision. Interpretation - Both cemented and uncemented fixations seem to be a viable option in this age group, but with a lower implant survival than in older patient groups.
Collapse
|
research-article |
6 |
29 |
15
|
Nivbrant B, Kärrholm J, Röhrl S, Hassander H, Wesslén B. Bone cement with reduced proportion of monomer in total hip arthroplasty: preclinical evaluation and randomized study of 47 cases with 5 years' follow-up. ACTA ORTHOPAEDICA SCANDINAVICA 2001; 72:572-84. [PMID: 11817871 DOI: 10.1080/000164701317268987] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Bone cement with reduced amount of monomer and low curing temperature may improve implant fixation due to reduced toxicity. We analyzed the mechanical, chemical and thermal properties of such a cement (Cemex Rx) using Palacos R as control. The in vivo performance of the 2 cements was also evaluated in a prospective randomized study of 47 hips, where either of the cement types was used to fixate Lubinus SP2 prostheses with the stem made of titanium alloy. Cemex Rx had a reduced tensile strength, probably because this cement was manually mixed, as recommended by the manufacturer. A standardized labor tory test showed lower curing temperature for Cemex, but measurements at 37 degrees and with prechilled Palacos R and Cemex Rx, as in clinical work, showed no difference. In the clinical study radiostereometric measurements of cup and stem migration showed similar values in the 2 groups up to 5 years after the operation. The cement mantle was stable in both groups, but the stems migrated similarly inside the cement mantle regardless of the type of cement used. Proximal wear was low (0.04-0.05 mm/year) and tended to be lower in the Cemex group (p = 0.02). Aluminum and vanadium levels in serum increased 5 years after the operation, but no difference was noted between the 2 groups. Collagen markers (PICP, ICTP) showed similar increases in bone turnover 6 weeks and 6 months after operation in both groups.
Collapse
|
Clinical Trial |
24 |
29 |
16
|
Brun OCL, Sund HN, Nordsletten L, Röhrl SM, Mjaaland KE. Component Placement in Direct Lateral vs Minimally Invasive Anterior Approach in Total Hip Arthroplasty: Radiographic Outcomes From a Prospective Randomized Controlled Trial. J Arthroplasty 2019; 34:1718-1722. [PMID: 31053468 DOI: 10.1016/j.arth.2019.04.003] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2019] [Revised: 04/01/2019] [Accepted: 04/02/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND End-stage coxarthrosis is increasingly common; however, limited evidence exists on the effect of direct lateral approach (DLA) and minimally invasive direct anterior approach (MIDA) on component placement in total hip arthroplasty (THA). We therefore conducted a prospective, randomized controlled trial to determine the component placement in DLA vs MIDA in THA. METHODS Between January 2012 and June 2013, 164 patients with clinically and radiologically confirmed coxarthrosis aged 20-80 years were randomized to either DLA or MIDA (active comparator). Excluded were patients with previous ipsilateral hip surgery, a body mass index >35 kg/m2, and/or mental disability. Primary clinical outcomes have been published elsewhere. Secondary outcomes included radiographic assessment of the acetabular component (cement-mantle thickness, inclination, and anteversion), femoral stem position (varus/valgus and THA index), offset restoration, and leg length discrepancy. RESULTS The mean cement-mantle was significantly thicker in zone 1 in the MIDA group (mean difference = 0.51 mm, 95% confidence interval [CI] 0.09-0.93, P = .018), and the mean degrees of inclination and anteversion were higher in the MIDA group (mean difference = 2.5°, 95% CI 0.3-4.6, P = .023 and mean difference = 3.6°, 95% CI 2.2-5.0, P < .0001, respectively). According to the defined reference range, cup inclination was more often adequate in the DLA group (67.9% (53/78) in the DLA group vs 52.4% (43/82) in the MIDA group, P = .045). There were no differences in frontal or lateral femoral stem position, global offset restoration, or leg length discrepancy. CONCLUSION In this population of Norwegian patients with coxarthrosis, radiographic assessment showed limited differences in component placement between MIDA and DLA. The findings suggest that component placement is similar in the 2 surgical approaches.
Collapse
|
Comparative Study |
6 |
25 |
17
|
Kibsgård TJ, Röhrl SM, Røise O, Sturesson B, Stuge B. Movement of the sacroiliac joint during the Active Straight Leg Raise test in patients with long-lasting severe sacroiliac joint pain. Clin Biomech (Bristol, Avon) 2017; 47:40-45. [PMID: 28582642 DOI: 10.1016/j.clinbiomech.2017.05.014] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/28/2016] [Revised: 05/05/2017] [Accepted: 05/25/2017] [Indexed: 02/07/2023]
Abstract
BACKGROUND The Active Straight Leg Raise is a functional test used in the assessment of pelvic girdle pain, and has shown to have good validity, reliability and responsiveness. The Active Straight Leg Raise is considered to examine the patients' ability to transfer load through the pelvis. It has been hypothesized that patients with pelvic girdle pain lack the ability to stabilize the pelvic girdle, probably due to instability or increased movement of the sacroiliac joint. This study examines the movement of the sacroiliac joints during the Active Straight Leg Raise in patients with pelvic girdle pain. METHODS Tantalum markers were inserted in the dorsal sacrum and ilium of 12 patients with long-lasting pelvic girdle pain scheduled for sacroiliac joint fusion surgery. Two to three weeks later movement of the sacroiliac joints during the Active Straight Leg Raise was measured with radiostereometric analysis. FINDINGS Small movements were detected. There was larger movement of the sacroiliac joint of the rested leg's sacroiliac joint compared to the lifted leg's side. A mean backward rotation of 0.8° and inward tilt of 0.3° were seen in the rested leg's sacroiliac joint. INTERPRETATION The movements of the sacroiliac joints during the Active Straight Leg Raise are small. There was a small backward rotation of the innominate bone relative to sacrum on the rested leg's side. Our findings contradict an earlier understanding that a forward rotation of the lifted leg's innominate occur while performing the Active Straight Leg Raise.
Collapse
|
|
8 |
22 |
18
|
Kibsgård TJ, Røise O, Sturesson B, Röhrl SM, Stuge B. Radiosteriometric analysis of movement in the sacroiliac joint during a single-leg stance in patients with long-lasting pelvic girdle pain. Clin Biomech (Bristol, Avon) 2014; 29:406-11. [PMID: 24602677 DOI: 10.1016/j.clinbiomech.2014.02.002] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2013] [Revised: 01/17/2014] [Accepted: 02/10/2014] [Indexed: 02/07/2023]
Abstract
BACKGROUND Chamberlain's projections (anterior-posterior X-ray of the pubic symphysis) have been used to diagnose sacroiliac joint mobility during the single-leg stance test. This study examined the movement in the sacroiliac joint during the single-leg stance test with precise radiostereometric analysis. METHODS Under general anesthesia, tantalum markers were inserted into the dorsal sacrum and the ilium of 11 patients with long-lasting and severe pelvic girdle pain. After two to three weeks, a radiostereometric analysis was conducted while the subjects performed a single-leg stance. FINDINGS Small movements were detected in the sacroiliac joint during the single-leg stance. In both the standing- and hanging-leg sacroiliac join, a total of 0.5 degree rotation was observed; however, no translations were detected. There were no differences in total movement between the standing- and hanging-leg sacroiliac joint. INTERPRETATION The movement in the sacroiliac joint during the single-leg stance is small and almost undetectable by the precise radiostereometric analysis. A complex movement pattern was seen during the test, with a combination of movements in the two joints. The interpretation of the results of this study is that, the Chamberlain examination likely is inadequate in the examination of sacroiliac joint movement in patients with pelvic girdle pain.
Collapse
|
|
11 |
21 |
19
|
Flatøy B, Röhrl SM, Bøe B, Nordsletten L. No medium-term advantage of electrochemical deposition of hydroxyapatite in cementless femoral stems. 5-year RSA and DXA results from a randomized controlled trial. Acta Orthop 2016; 87:42-7. [PMID: 26364953 PMCID: PMC4940590 DOI: 10.3109/17453674.2015.1084768] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Hydroxyapatite has been used for a long time as an adjunct to enhance cementless fixation. The benefit of this is still debated, but new methods of hydroxyapatite deposition have emerged, offering possible gains. In order to investigate this further, we compared the migration pattern and periprosthetic bone remodeling in a cementless femoral stem with either electrochemically deposited hydroxyapatite-called Bonemaster (BM)-or a conventional plasma-sprayed hydroxyapatite (HA) coating. PATIENTS AND METHODS 55 hips were randomized to either BM or HA cementless femoral stems. Patients were followed with radiostereometry (RSA), dual-energy X-ray absorptiometry (DXA), radiographic measurements, and hip questionnaires for 5 years. RESULTS For both stems, migration occurred mainly as subsidence and retroversion during the first 3 months. The BM group had a higher retroversion rate of 0.17° per month during this period, as compared to 0.06° per month for the HA group (p = 0.006). Thereafter, there was almost no movement in any direction for both stem types. Bone resorption occurred mainly during the first year, and subsequently decreased to a rate close to what is seen in normal ageing. The greatest total decrease occurred in Gruen zones 1 and 7, similar in the groups at 5 years. There was a slightly higher resorption rate in Gruen zone 7 from 2 to 5 years in the BM group (1.3% per year; p = 0.04), but in a magnitude that would scarcely affect stem stability or survival. INTERPRETATION There were no clinically relevant differences between the 2 stems regarding stability or periprosthetic bone loss at 5 years. Electrochemically deposited HA does not appear to affect fixation or bone remodeling when compared to conventional plasma spraying at 5 years. Thus, at this point, Bonemaster appears to be safe.
Collapse
|
research-article |
9 |
21 |
20
|
Van Leeuwen JAMJ, Snorrason F, Röhrl SM. No radiological and clinical advantages with patient-specific positioning guides in total knee replacement. Acta Orthop 2018; 89:89-94. [PMID: 29161930 PMCID: PMC5810839 DOI: 10.1080/17453674.2017.1393732] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Although the use of patient-specific positioning guides (PSPGs) in total knee replacement (TKR) in theory is promising, the technique has not yet proven its superior- ity compared with the conventional method. We compared radio- logical alignment and clinical outcome between TKR performed with the use of PSPGs and the conventional operation method. Patients and methods - 3 hospitals participated in a prospec- tive trial. 109 patients were randomized to either the conventional method or to the use of PSPGs. Postoperatively a full-length standing anteroposterior radiograph and a postoperative CT scan were taken. On the CT scan the alignments were measured for both the femoral and tibial components in the frontal, sagit- tal, and axial plane. The Knee injury and Osteoarthritis Outcome Score (KOOS), the Eurocol-5D-3L (Eq5D) descriptive system and visual analogue scale (VAS), a pain score (NRS), and range of motion (ROM) were recorded preoperatively, and at 3 months, 1, and 2 years. The operation time and length of hospital stay were recorded. Results - 90 patients were available for postoperative CT mea- surements. A statistically significant difference was found between the conventional TKR instrumentation and the use of PSPGs for the frontal femoral (mean (SD) 0.6° (1.7) vs. -0.3° (2.2), CI 0.08 to 1.69) and tibial (-0.3° (1.5) vs. 0.9° (2.1), CI -1.98 to -0.44) compo- nent angles and for the tibial alignment in the sagittal plane (-3.8° (3.0) vs. -2.2° (2.5), CI -2.72; -0.42). The proportions of outliers were similar between the groups as well as the hip-knee-ankle angle, the KOOS sub scores, the Eq5D, pain (NRS), ROM, opera- tion time, and length of hospital stay. Interpretation - The use of PSPGs requires a preoperative CT scan or MRI and the guides have an additional cost. As this study was not able to prove any extra benefit of the use of PSPGs we recommend the conventional operation method for TKR.
Collapse
|
research-article |
7 |
18 |
21
|
Øhrn FD, Gøthesen Ø, Låstad Lygre SH, Peng Y, Lian ØB, Lewis PL, Furnes O, Röhrl SM. Decreased Survival of Medial Pivot Designs Compared with Cruciate-retaining Designs in TKA Without Patellar Resurfacing. Clin Orthop Relat Res 2020; 478:1207-1218. [PMID: 31977446 PMCID: PMC7319362 DOI: 10.1097/corr.0000000000001120] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND The medial pivot TKA design was introduced in the 1990s. These are fixed-bearing, medial-conforming implants with virtually no translation in the medial part of the knee, in contrast to the flat lateral part of the insert allowing for translation similar to the native knee during flexion and extension. Most primary TKAs performed in Norway and Australia are cruciate-retaining. All of the medial pivot implants in our study are cruciate-sacrificing but without a post-cam mechanism. The medial pivot implant design was developed to more closely mimic native knee motion, in the hope of improving function, and not primarily as a more constrained knee for difficult cases. In the past 10 to 12 years, a second-generation medial-pivot design has emerged, but there are no larger registry studies on the survival of these implants. Both cruciate-retaining and medial pivot designs are reported in the Australian and Norwegian registries, allowing for large-scale, comparative survivorship studies. QUESTIONS/PURPOSES (1) Is there any difference in survival between the medial pivot design and the three most commonly used cruciate-retaining TKA designs? (2) Is there any difference in survival among the different medial pivot implant designs? (3) What are the main indications for revision of medial pivot TKAs? METHODS Registry data from the Australian Orthopaedic Association National Joint Replacement Registry and Norwegian Arthroplasty Register from 2005 until the end of 2017 were used to compare the five different brands of medial pivot TKA designs (total primary TKAs assessed: 6310). In Australia, the study group of medial pivot implants represented 9% (6012 of 72,477) of the total number of cemented/hybrid TKAs without patellar resurfacing; 345 had cementless femoral components. In Norway, the study group represented 1% (298 of 47,820) of the total number of TKAs with cemented tibias without patellar resurfacing; all had cemented femoral components. The control group consisted of the three most commonly used cruciate-retaining TKA designs (n = 70,870; Australia n = 54,554; Norway n = 16,316). All TKAs used a fixed-bearing, cemented tibial component and did not involve patella resurfacing. Kaplan-Meier survival analysis was assessed to estimate survivorship. We compared the groups by calculating the hazard ratios (HR) using Cox regression adjusted for age, gender and preoperative diagnosis with 95% CI. To answer our third question, we calculated the percentage of each revision indication from the total number of revisions in each group, and used a Cox regression analysis to compare revision causes and HRs. Analyses were performed separately by each registry. Accounting for competing risks (Fine and Gray) did not alter our findings []. RESULTS After controlling for potential confounding variables such as gender, age and preoperative diagnosis, we found an increased revision risk for the medial pivot compared with cruciate-retaining TKA designs in Australia (HR 1.4 [95% CI 1.2 to 1.7]; p < 0.001), but not in Norway (HR 1.5 [95% CI 0.9 to 2.4]; p = 0.1). Two brands of the medial pivot design reported to the AOANJRR showed an increased risk of revision compared with cruciate-retaining designs: the Advance® II MP (HR 1.7 [95% CI 1.2 to 2.6]; p = 0.004) and the GMK® Sphere (HR 2.0 [95% CI 1.5 to 2.6]; p < 0.001), whereas the MRK (HR 0.7 [95% CI 0.4 to 1.5]; p = 0.4), the Evolution® MP (HR 1.4 [95% CI 1.0 to 1.9]; p = 0.06) and the SAIPH® (HR 0.9 [95% CI 0.5 to 1.5]; p = 0.7) showed no difference. The most common reasons for revision of medial pivot implants in Australia were infection (27%), pain alone (19%), patellar erosion (13%), loosening/lysis (12%); in Norway the primary indications were loosening/lysis (28%), instability (28%), malalignment (11%) and pain alone (11%). CONCLUSIONS The medial pivot TKA design as a group had a higher revision rate than cruciate-retaining fixed-bearing controls in TKA performed without patellar component resurfacing. By brand, the Advance II MP and the GMK Sphere had inferior survivorship, whereas the MRK, the SAIPH and the Evolution MP had no differences in survivorship compared with cruciate-retaining controls. In Australia, TKAs with the medial pivot design without patella resurfacing had a higher rate of revisions for instability, malalignment, and patella erosion. In Norway, there was an increased risk of revision for lysis and loosening compared with the cruciate-retaining design. Several of these implants had short follow-up in this study. Further registry studies with longer follow up are therefore necessary. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
|
research-article |
5 |
16 |
22
|
Sandberg OH, Kärrholm J, Olivecrona H, Röhrl SM, Sköldenberg OG, Brodén C. Computed tomography-based radiostereometric analysis in orthopedic research: practical guidelines. Acta Orthop 2023; 94:373-378. [PMID: 37493579 PMCID: PMC10370409 DOI: 10.2340/17453674.2023.15337] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Indexed: 07/27/2023] Open
Abstract
Early implant migration is an indicator of the long-term survival/failure of implants. CT-based radio-stereometric analysis (CT-RSA) is a precise method for measuring and visualizing implant migration in vivo using image processing of CT scans. This makes the method widely applicable to orthopedic researcher. Since its development in the early 2000s, CT-RSA has benefited from breakthroughs in CT and computing technology. These advancements have allowed for the acquisition of images with higher resolution at a much lower radiation dose. As a result, the measurement precision of CT-RSA is now comparable to that of the current gold standard technology while still compatible with most ethical considerations regarding radiation exposure. In this review we present bests practices for the successful execution of CT-RSA research projects. These practices are based on experience from projects on the hip, knee, shoulder, lower back, cervical spine, foot, pelvis, and wrist.
Collapse
|
|
2 |
15 |
23
|
Øhrn FD, Van Leeuwen J, Tsukanaka M, Röhrl SM. A 2-year RSA study of the Vanguard CR total knee system: A randomized controlled trial comparing patient-specific positioning guides with conventional technique. Acta Orthop 2018; 89:418-424. [PMID: 29739264 PMCID: PMC6066770 DOI: 10.1080/17453674.2018.1470866] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - There is some concern regarding the revision rate of the Vanguard CR TKA in 1 registry, and the literature is ambiguous about the efficacy of patient-specific positioning guides (PSPGs). The objective of this study was to investigate the stability of the cemented Vanguard CR Total Knee using 2 different surgical techniques. Our hypothesis was that there is no difference in migration when implanting the Vanguard CR with either PSPGs or conventional technique. We hereby present a randomized controlled trial of 2-year follow-up with radiostereometric analysis (RSA). Patients and methods - 40 TKAs were performed between 2011 and 2013 with either PSPGs or the conventional technique and 22 of these were investigated with RSA. Results - The PSPG (8 knees) and the conventional (14 knees) groups had a mean maximum total point motion (MTPM) (95% CI) of 0.83 (0.48-1.18) vs. 0.70 (0.43-0.97) mm, 1.03 (0.60-1.43) vs. 0.86 (0.53-1.19), and 1.46 (1.07-1.85) vs. 0.80 (0.52-1.43) at 3, 12, and 24 months respectively (p = 0.1). 5 implants had either an MTPM >1.6 mm at 12 months and/or a migration of more than 0.2 mm between 1- and 2-year follow-ups. 2 of these also had a peripheral subsidence of more than 0.6 mm at 2 years. Interpretation - 5 implants (3 in the PSPG group) were found to be at risk of later aseptic loosening. The PSPG group continuously migrated between 12 and 24 months. The conventional group had an initial high migration between postoperative and 3 months, but seemed more stable after 1 year. Although the difference was not statistically significant, we think the migration in the PSPG group is of some concern.
Collapse
|
research-article |
7 |
14 |
24
|
Holm-Glad T, Røkkum M, Röhrl SM, Roness S, Godang K, Reigstad O. A randomized controlled trial comparing two modern total wrist arthroplasties : improved function with stable implants, but high complication rates in non-rheumatoid wrists at two years. Bone Joint J 2022; 104-B:1132-1141. [PMID: 36177637 DOI: 10.1302/0301-620x.104b10.bjj-2022-0201.r2] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS To analyze the short-term outcome of two types of total wrist arthroplasty (TWA) in terms of wrist function, migration, and periprosthetic bone behaviour. METHODS A total of 40 patients suffering from non-rheumatoid wrist arthritis were enrolled in a randomized controlled trial comparing the ReMotion and Motec TWAs. Patient-rated and functional outcomes, radiological changes, blood metal ion levels, migration measured by model-based radiostereometric analysis (RSA), bone mineral density (BMD) measured by dual-energy X-ray absorptiometry (DXA), complications, loosening, and revision rates at two years were compared. RESULTS Patient-Rated Wrist and Hand Evaluation (PRWHE) scores, abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire scores, and pain improved similarly and significantly in both groups. Wrist motion improved significantly in the Motec group only, and forearm rotation in the ReMotion group only. Cobalt (Co) and chromium (Cr) blood ion levels were significantly higher in the metal-on-metal (MoM) Motec group than in the metal-on-polyethylene (MoP) ReMotion group. Mean total translation was 0.65 mm (95% confidence interval (CI) 0.26 to 1.12) and 0.27 mm (95% CI 0.14 to 0.47) for the ReMotion carpal and radial components, and 0.32 mm (95% CI 0.22 to 0.45) and 0.26 mm (95% CI 0.20 to 0.34) for the Motec metacarpal and radial components, respectively. Apart from dorsal and volar tilts, which were significantly higher for the radial ReMotion than for the Motec component, no significant differences in absolute migration occurred. BMD around the radial components never returned to baseline. Almost one-third of patients required reoperation due to complications. Two ReMotion implants were revised to Motec TWAs due to carpal component loosening, and three Motec MoM articulations were revised to metal-on-polyether ether ketone due to painful synovitis. CONCLUSION Both implants provided matched function and were stable at short-term follow-up, but with a high complication rate. This procedure should be restricted to specialist centres undertaking prospective analysis until its role is clarified.Cite this article: Bone Joint J 2022;104-B(10):1132-1141.
Collapse
|
Randomized Controlled Trial |
3 |
14 |
25
|
Lindalen E, Havelin LI, Nordsletten L, Dybvik E, Fenstad AM, Hallan G, Furnes O, Høvik Ø, Röhrl SM. Is reverse hybrid hip replacement the solution? Acta Orthop 2011; 82:639-45. [PMID: 21999624 PMCID: PMC3247878 DOI: 10.3109/17453674.2011.623569] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Reverse hybrid hip replacement uses a cemented all-polyethylene cup and an uncemented stem. Despite increasing use of this method in Scandinavia, there has been very little documentation of results. We have therefore analyzed the results from the Norwegian Arthroplasty Register (NAR), with up to 10 years of follow-up. PATIENTS AND METHODS The NAR has been collecting data on total hip replacement (THR) since 1987. Reverse hybrid hip replacements were used mainly from 2000. We extracted data on reverse hybrid THR from this year onward until December 31, 2009, and compared the results with those from cemented implants over the same period. Specific cup/stem combinations involving 100 cases or more were selected. In addition, only combinations that were taken into use in 2005 or earlier were included. 3,963 operations in 3,630 patients were included. We used the Kaplan-Meier method and Cox regression analysis for estimation of prosthesis survival and relative risk of revision. The main endpoint was revision for any cause, but we also performed specific analyses on different reasons for revision. RESULTS We found equal survival to that from cemented THR at 5 years (cemented: 97.0% (95% CI: 96.8-97.2); reverse hybrid: 96.7% (96.0-97.4)) and at 7 years (cemented: 96.0% (95.7-96.2); reverse hybrid: 95.6% (94.4-96.7)). Adjusted relative risk of revision of the reverse hybrids was 1.1 (0.9-1.4). In patients under 60 years of age, we found similar survival of the 2 groups at 5 and 7 years, with an adjusted relative risk of revision of reverse hybrids of 0.9 (0.6-1.3) compared to cemented implants. INTERPRETATION With a follow-up of up to 10 years, reverse hybrid THRs performed well, and similarly to all-cemented THRs from the same time period. The reverse hybrid method might therefore be an alternative to all-cemented THR. Longer follow-up time is needed to evaluate whether reverse hybrid hip replacement has any advantages over all-cemented THR.
Collapse
|
research-article |
14 |
14 |